OCTOPLUS<br />

FLUORESCENCE IMAGER<br />

for powerful & fast 2D image acquisition<br />

The gold standard for CCD-based RGB fluorescence detection<br />

Approved for


Octoplus fluorescence <strong>imager</strong><br />

For powerful & fast 2D image acquisition<br />

Accurately analyzing fluorescent labeled proteins requires a high performing imaging system.<br />

The new OCTOPLUS FLUORESCENCE IMAGER has been specifically developed for experiments<br />

with powerful Refraction-2D and Saturn-2D technologies.<br />

The system combines the fast image acquisition of fluorescent gels and blots with high sensitivity<br />

and robust setup required for daily routine. Thereby, the OCTOPLUS FLUORESCENCE<br />

IMAGER sets a unique standard for fast fluorescence multiplex 2D imaging as well as ECL,<br />

and optionally for silver- or Coomassie® blue stained gels.<br />

Simultaneous fluorescence imaging of up to 4 different dyes<br />

Sensitive & quantitative chemiluminescence<br />

Bright colorimetric imaging<br />

Made in Germany


1D Fluorescence Imaging<br />

The OCTOPLUS power LED module with diffuser lenses excites up to 4 different fluorophores.<br />

Highly specific excitation and emission filters avoid any crosstalk issues. Figure 1<br />

shows 4 differently fluorescent labeled proteins separated by SDS-PAGE and imaged by<br />

OCTOPLUS. Complex samples of less than 1 µg of protein can be analyzed with high<br />

accuracy (fig. 2).<br />

1.000 0.500 0.250 0.125 0.062 0.031 0.016<br />

Protein load (μg)<br />

BSA (66.0 kDa)<br />

+ G-Dye200<br />

Casein (24.0 kDa)<br />

+ T-Rex 330<br />

Lactoglobulin (18.4 kDa)<br />

+ G-Dye100<br />

RNaseA (13.7 kDa)<br />

+ T-Red 410<br />

Fig. 1. Serial dilution of BSA, Casein, Lactoglobulin and RNase A labeled with G-Dye and T-Dye<br />

fluorophores. Proteins were separated by SDS-PAGE and scanned by OCTOPLUS. Scanning times:<br />

G-Dye200: 50 sec, T-Rex 330: 30 sec, G-Dye100: 30 sec, T-Red 410: 90 sec.<br />

5.000 1.000 0.500 0.250 0.125 0.062 Protein load (μg)<br />

Fig. 2. T-Green 210 labeled E. coli total protein extract. Separation by<br />

SDS-PAGE. OCTOPLUS scanning time: 50 sec.


Signal sensitivity & linearity<br />

The OCTOPLUS system detects fluorescent signals from minimally labeled proteins (one<br />

fluorophore per protein) in the lower nanogram range. Even in this range, the signal<br />

linearity remains at an ideal level (R 2 = 0.996 [fig.3.]).<br />

1.000 0.500 0.250 0.125 0.062 0.031 0.016 0.008<br />

Protein load (μg)<br />

Signal intensity (AU)<br />

100<br />

80<br />

60<br />

R² = 0.996<br />

40<br />

20<br />

0<br />

0.0 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.0<br />

Amount of protein (µg)<br />

Fig. 3. Serial dilution of BSA minimally labeled with T-Rex 330. Proteins were separated by<br />

SDS-PAGE and scanned with OCTOPLUS. Signal intensities were analyzed by LabImage 1D L340<br />

(Kapelan GmbH, Germany).<br />

Related<br />

products<br />

T-Dye<br />

fast & easy<br />

protein<br />

labeling kits


2D Fluorescence imaging<br />

The OCTOPLUS FLUORESCENCE IMAGER is especially designed for Refraction-2D and<br />

Saturn-2D multiplex fluorescence 2D gel analysis. The powerful combination of carefully<br />

developed system components for fluorescence light excitation and detection create a<br />

perfect system for sensitive image acquisition.<br />

Scanning time for a single Refraction-2D gel (images for G-Dye100, G-Dye200 and<br />

G-Dye300) is performed within minutes. A complete series of gels (e.g. six Refraction-2D<br />

gels) can be scanned in less than one hour.<br />

5 min<br />

total image<br />

acquisition time<br />

Refraction-2D analysis of two different Arabidopsis thaliana ecotypes.<br />

Related<br />

products<br />

Refraction-2D<br />

labeling kit<br />

for powerful<br />

multiplexing<br />

Saturn-2D<br />

labeling kit<br />

for scarce<br />

samples


OCTOPLUS Fluorescence Imager<br />

Blue LED, G100 filter<br />

Bit depth: 16 bit<br />

Pixel size: 7 µm @ 55,000 full well capacity<br />

Gel size: 24 x 20 cm, pH 3-10<br />

Sample: 50 µg total protein from E. coli<br />

Fluorescent label: G-Dye100<br />

Scanning time: 20 sec<br />

OCTOPLUS Fluorescence Imager<br />

Green LED, G200 filter<br />

Bit depth: 16 bit<br />

Pixel size: 7 µm @ 55,000 full well capacity<br />

Gel size: 24 x 20 cm, pH 3-10<br />

Sample: 50 µg total protein from E. coli<br />

Fluorescent label: G-Dye200<br />

Scanning time: 50 sec<br />

OCTOPLUS Fluorescence Imager<br />

Red LED, G300 filter<br />

Bit depth: 16 bit<br />

Pixel size: 7 µm @ 55,000 full well capacity<br />

Gel size: 24 x 20 cm, pH 3-10<br />

Sample: 50 µg total protein from E. coli<br />

Fluorescent label: G-Dye300<br />

Scanning time: 20 sec


Chemiluminescence<br />

With a superior CCD chip, a lab quality lens and a 16 bit dynamic range (4.7 orders of<br />

magnitude) OCTOPLUS captures chemiluminescence at the highest resolution available on<br />

the market.<br />

1000 500 250 125 62.5 31.25 16 8<br />

Protein load (pg)<br />

Fig. 4. Serial dilution of Casein. Proteins were separated by SDS-PAGE, then transfered by<br />

Western blotting onto a nitrocellulose membrane. The blot was subjected to a Casein antibody<br />

and then to a HRP-conjugated secondary antibody. The proteins were detected by ECL (Pierce)<br />

with an exposure time of 2.5 min.<br />

Colorimetric applications (optional)<br />

Using the optional white transillumination module, the perfect imaging of silver or<br />

Coomassie® blue stained gels can be achieved.<br />

Fig. 5a and 5b. Colorimetric analysis of Coomassie® blue stained 2D and 1D gels.


Octoplus fluorescence <strong>imager</strong><br />

Image capture software<br />

The image acquisition is performed by the easy-to-use OCTOPLUS image capture software.<br />

Your raw image data are saved and a copy is taken for further analysis by 1D and 2D<br />

software. This data separation allows you to always revert back to your original images.<br />

Related<br />

products<br />

2DXPLORER<br />

labeling kits and<br />

analysis software<br />

per 2D gel


Octoplus inside<br />

Superior optic and<br />

CCD camera system<br />

Fast remote focus<br />

Adjustable power<br />

LED sample tray<br />

Robust housing<br />

for daily routine


Instrument specifications<br />

CCD Kamera<br />

Kodak CCD full frame chip with mircolens technology<br />

Cooling<br />

4-stage Peltier cooling (delta T -60°C)<br />

Chip resolution<br />

3.2 MP<br />

Pixel size Approx. 7 µm, full well capacity 55,000 e-<br />

Dynamic range<br />

16-bit (65,536 grey levels), 4.7 orders of magnitude<br />

Lens<br />

Schneider-Kreuznach (F: 0.95 / 25 mm)<br />

Focusing<br />

Manual remote operation<br />

Binning modes 1 x 1, 2 x 2, 3 x 3, ... , 10 x 10<br />

Fluorescence unit<br />

Power LED module for RGB fluorescence detection,<br />

upgradable to IR fluorescence detection<br />

Filter<br />

Highly specific blue, red & green filter (standard), highly<br />

specific IR filter optional, upgradable to 3 additional filters<br />

Sample size<br />

22 x 28 cm<br />

Interface<br />

USB 2.0 / Ethernet<br />

Temperature Up to 30°C<br />

Size (W x H x D)<br />

41 cm x 90 cm x 40 cm<br />

Weight<br />

Approx. 45 kg<br />

Supply voltage<br />

100 - 240 V<br />

Frequency<br />

50 / 60 Hz


Ordering information<br />

PR 130 OCTOPLUS Fluorescence Imager<br />

• Power LED module for highly specific blue, green & red fluorescence<br />

• Chemiluminescence<br />

• Image capture and 1D analysis software<br />

PR131 Highly specific far red power LED module<br />

PR132 White light transmission module<br />

PR133 Analysis PC with high resolution display (21.5”)<br />

PR136 2D analysis software Delta2D<br />

Related products<br />

PR03<br />

PR04<br />

Low fluorescent glass cassettes, size 8 x 10 cm<br />

Low fluorescent glass cassettes, size 22 x 27.5 cm<br />

Contact<br />

<strong>NH</strong> <strong>DyeAGNOSTICS</strong> GmbH<br />

Weinbergweg 23<br />

D-06120 Halle<br />

Germany<br />

Fon: +49 (0) 345-2799 6413<br />

Fax: +49 (0) 345-2799 6412<br />

E-Mail: info@dyeagnostics.com<br />

sales@dyeagnostics.com<br />

www.dyeagnostics.com<br />

copyright© <strong>NH</strong> <strong>DyeAGNOSTICS</strong> 2012<br />

Design & Layout: Tobias Roth, Halle

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!