OctOplus fluOrescence imager - NH DyeAGNOSTICS
OctOplus fluOrescence imager - NH DyeAGNOSTICS
OctOplus fluOrescence imager - NH DyeAGNOSTICS
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
OCTOPLUS<br />
FLUORESCENCE IMAGER<br />
for powerful & fast 2D image acquisition<br />
The gold standard for CCD-based RGB fluorescence detection<br />
Approved for
Octoplus fluorescence <strong>imager</strong><br />
For powerful & fast 2D image acquisition<br />
Accurately analyzing fluorescent labeled proteins requires a high performing imaging system.<br />
The new OCTOPLUS FLUORESCENCE IMAGER has been specifically developed for experiments<br />
with powerful Refraction-2D and Saturn-2D technologies.<br />
The system combines the fast image acquisition of fluorescent gels and blots with high sensitivity<br />
and robust setup required for daily routine. Thereby, the OCTOPLUS FLUORESCENCE<br />
IMAGER sets a unique standard for fast fluorescence multiplex 2D imaging as well as ECL,<br />
and optionally for silver- or Coomassie® blue stained gels.<br />
Simultaneous fluorescence imaging of up to 4 different dyes<br />
Sensitive & quantitative chemiluminescence<br />
Bright colorimetric imaging<br />
Made in Germany
1D Fluorescence Imaging<br />
The OCTOPLUS power LED module with diffuser lenses excites up to 4 different fluorophores.<br />
Highly specific excitation and emission filters avoid any crosstalk issues. Figure 1<br />
shows 4 differently fluorescent labeled proteins separated by SDS-PAGE and imaged by<br />
OCTOPLUS. Complex samples of less than 1 µg of protein can be analyzed with high<br />
accuracy (fig. 2).<br />
1.000 0.500 0.250 0.125 0.062 0.031 0.016<br />
Protein load (μg)<br />
BSA (66.0 kDa)<br />
+ G-Dye200<br />
Casein (24.0 kDa)<br />
+ T-Rex 330<br />
Lactoglobulin (18.4 kDa)<br />
+ G-Dye100<br />
RNaseA (13.7 kDa)<br />
+ T-Red 410<br />
Fig. 1. Serial dilution of BSA, Casein, Lactoglobulin and RNase A labeled with G-Dye and T-Dye<br />
fluorophores. Proteins were separated by SDS-PAGE and scanned by OCTOPLUS. Scanning times:<br />
G-Dye200: 50 sec, T-Rex 330: 30 sec, G-Dye100: 30 sec, T-Red 410: 90 sec.<br />
5.000 1.000 0.500 0.250 0.125 0.062 Protein load (μg)<br />
Fig. 2. T-Green 210 labeled E. coli total protein extract. Separation by<br />
SDS-PAGE. OCTOPLUS scanning time: 50 sec.
Signal sensitivity & linearity<br />
The OCTOPLUS system detects fluorescent signals from minimally labeled proteins (one<br />
fluorophore per protein) in the lower nanogram range. Even in this range, the signal<br />
linearity remains at an ideal level (R 2 = 0.996 [fig.3.]).<br />
1.000 0.500 0.250 0.125 0.062 0.031 0.016 0.008<br />
Protein load (μg)<br />
Signal intensity (AU)<br />
100<br />
80<br />
60<br />
R² = 0.996<br />
40<br />
20<br />
0<br />
0.0 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.0<br />
Amount of protein (µg)<br />
Fig. 3. Serial dilution of BSA minimally labeled with T-Rex 330. Proteins were separated by<br />
SDS-PAGE and scanned with OCTOPLUS. Signal intensities were analyzed by LabImage 1D L340<br />
(Kapelan GmbH, Germany).<br />
Related<br />
products<br />
T-Dye<br />
fast & easy<br />
protein<br />
labeling kits
2D Fluorescence imaging<br />
The OCTOPLUS FLUORESCENCE IMAGER is especially designed for Refraction-2D and<br />
Saturn-2D multiplex fluorescence 2D gel analysis. The powerful combination of carefully<br />
developed system components for fluorescence light excitation and detection create a<br />
perfect system for sensitive image acquisition.<br />
Scanning time for a single Refraction-2D gel (images for G-Dye100, G-Dye200 and<br />
G-Dye300) is performed within minutes. A complete series of gels (e.g. six Refraction-2D<br />
gels) can be scanned in less than one hour.<br />
5 min<br />
total image<br />
acquisition time<br />
Refraction-2D analysis of two different Arabidopsis thaliana ecotypes.<br />
Related<br />
products<br />
Refraction-2D<br />
labeling kit<br />
for powerful<br />
multiplexing<br />
Saturn-2D<br />
labeling kit<br />
for scarce<br />
samples
OCTOPLUS Fluorescence Imager<br />
Blue LED, G100 filter<br />
Bit depth: 16 bit<br />
Pixel size: 7 µm @ 55,000 full well capacity<br />
Gel size: 24 x 20 cm, pH 3-10<br />
Sample: 50 µg total protein from E. coli<br />
Fluorescent label: G-Dye100<br />
Scanning time: 20 sec<br />
OCTOPLUS Fluorescence Imager<br />
Green LED, G200 filter<br />
Bit depth: 16 bit<br />
Pixel size: 7 µm @ 55,000 full well capacity<br />
Gel size: 24 x 20 cm, pH 3-10<br />
Sample: 50 µg total protein from E. coli<br />
Fluorescent label: G-Dye200<br />
Scanning time: 50 sec<br />
OCTOPLUS Fluorescence Imager<br />
Red LED, G300 filter<br />
Bit depth: 16 bit<br />
Pixel size: 7 µm @ 55,000 full well capacity<br />
Gel size: 24 x 20 cm, pH 3-10<br />
Sample: 50 µg total protein from E. coli<br />
Fluorescent label: G-Dye300<br />
Scanning time: 20 sec
Chemiluminescence<br />
With a superior CCD chip, a lab quality lens and a 16 bit dynamic range (4.7 orders of<br />
magnitude) OCTOPLUS captures chemiluminescence at the highest resolution available on<br />
the market.<br />
1000 500 250 125 62.5 31.25 16 8<br />
Protein load (pg)<br />
Fig. 4. Serial dilution of Casein. Proteins were separated by SDS-PAGE, then transfered by<br />
Western blotting onto a nitrocellulose membrane. The blot was subjected to a Casein antibody<br />
and then to a HRP-conjugated secondary antibody. The proteins were detected by ECL (Pierce)<br />
with an exposure time of 2.5 min.<br />
Colorimetric applications (optional)<br />
Using the optional white transillumination module, the perfect imaging of silver or<br />
Coomassie® blue stained gels can be achieved.<br />
Fig. 5a and 5b. Colorimetric analysis of Coomassie® blue stained 2D and 1D gels.
Octoplus fluorescence <strong>imager</strong><br />
Image capture software<br />
The image acquisition is performed by the easy-to-use OCTOPLUS image capture software.<br />
Your raw image data are saved and a copy is taken for further analysis by 1D and 2D<br />
software. This data separation allows you to always revert back to your original images.<br />
Related<br />
products<br />
2DXPLORER<br />
labeling kits and<br />
analysis software<br />
per 2D gel
Octoplus inside<br />
Superior optic and<br />
CCD camera system<br />
Fast remote focus<br />
Adjustable power<br />
LED sample tray<br />
Robust housing<br />
for daily routine
Instrument specifications<br />
CCD Kamera<br />
Kodak CCD full frame chip with mircolens technology<br />
Cooling<br />
4-stage Peltier cooling (delta T -60°C)<br />
Chip resolution<br />
3.2 MP<br />
Pixel size Approx. 7 µm, full well capacity 55,000 e-<br />
Dynamic range<br />
16-bit (65,536 grey levels), 4.7 orders of magnitude<br />
Lens<br />
Schneider-Kreuznach (F: 0.95 / 25 mm)<br />
Focusing<br />
Manual remote operation<br />
Binning modes 1 x 1, 2 x 2, 3 x 3, ... , 10 x 10<br />
Fluorescence unit<br />
Power LED module for RGB fluorescence detection,<br />
upgradable to IR fluorescence detection<br />
Filter<br />
Highly specific blue, red & green filter (standard), highly<br />
specific IR filter optional, upgradable to 3 additional filters<br />
Sample size<br />
22 x 28 cm<br />
Interface<br />
USB 2.0 / Ethernet<br />
Temperature Up to 30°C<br />
Size (W x H x D)<br />
41 cm x 90 cm x 40 cm<br />
Weight<br />
Approx. 45 kg<br />
Supply voltage<br />
100 - 240 V<br />
Frequency<br />
50 / 60 Hz
Ordering information<br />
PR 130 OCTOPLUS Fluorescence Imager<br />
• Power LED module for highly specific blue, green & red fluorescence<br />
• Chemiluminescence<br />
• Image capture and 1D analysis software<br />
PR131 Highly specific far red power LED module<br />
PR132 White light transmission module<br />
PR133 Analysis PC with high resolution display (21.5”)<br />
PR136 2D analysis software Delta2D<br />
Related products<br />
PR03<br />
PR04<br />
Low fluorescent glass cassettes, size 8 x 10 cm<br />
Low fluorescent glass cassettes, size 22 x 27.5 cm<br />
Contact<br />
<strong>NH</strong> <strong>DyeAGNOSTICS</strong> GmbH<br />
Weinbergweg 23<br />
D-06120 Halle<br />
Germany<br />
Fon: +49 (0) 345-2799 6413<br />
Fax: +49 (0) 345-2799 6412<br />
E-Mail: info@dyeagnostics.com<br />
sales@dyeagnostics.com<br />
www.dyeagnostics.com<br />
copyright© <strong>NH</strong> <strong>DyeAGNOSTICS</strong> 2012<br />
Design & Layout: Tobias Roth, Halle