Sterilization Units
Sterilization Units<br />
<strong>640</strong> <strong>SO</strong><br />
The efficacy of sterilization’s process is determining to eliminate the risks which comes through the utilize of<br />
the medical dispositives on the human body.<br />
For this reason <strong>Cisa</strong> has carried on a research and development program having the target to realize a<br />
complete range of machines to meet all the kind of sterilization both in production terms and application.<br />
And every <strong>Cisa</strong> machine is designed and manufactured on the same principles: easy of use and maintenance,<br />
safety, and reliability.<br />
2
Maintenance<br />
All <strong>Cisa</strong> machines are designed for easy access<br />
and maintenance.<br />
Access is from the front, and the position of every<br />
component is designed so as to make it to reach<br />
and service.<br />
Technical assistance, ordinary maintenance and<br />
eventual repairs are therefore quicker, simpler<br />
and more cost effective.<br />
For each main component there is a maintenance<br />
programme directly accessed through the touch<br />
screen.<br />
The maintenance programmes also include the<br />
steam generator, which automatically drains so<br />
as to eliminate water contaminants or deposits.<br />
Furthermore it is foreseen an interface to make<br />
the distant maintenance.<br />
Structure and Machine Design<br />
The technology featured in every <strong>Cisa</strong> machine isn’t only<br />
limited to the digital process control.<br />
The <strong>Cisa</strong> research team has also dedicated a lot of effort to<br />
the structure and construction of the machines.<br />
A thorough choice of materials and components guarantee<br />
the safety and durability of the machine under every<br />
circumstance.<br />
All <strong>Cisa</strong> machines are manufactured with the same<br />
standards of hygiene and dependability, and feature,<br />
amongst others, the following characteristics:<br />
• Sterilization chamber, jacket and doors in stainless steel<br />
chrome-nickel-molybdenum-titanium<br />
• Design and type approval at 3,5 relative bar<br />
• Frontal frame of the sterilization chamber in single piece<br />
homogeneous with incorporated seat gasket and door<br />
guides<br />
3<br />
• Mirror finish electrolytic polishing treatment<br />
• Steam operated dynamic gasket, or in alternative<br />
mechanical compression seal<br />
• Pneumatic closure of the sterilization chamber with<br />
automatic safety locking and vertical or horizontal sliding<br />
door<br />
• Pure self-lubricating silicone gaskets<br />
• Non toxic fire resistant insulation foam, with extremely<br />
low thermal conductivity and no release of particles<br />
• Main supporting frame, front and internal panels in<br />
stainless steel chrome-nickel-molybdenum<br />
• Compact architecture, with overall dimensions always<br />
restricted in relation to the machine capacity<br />
• Effortless installation, with ease of positioning on the floor<br />
and connection to the main utilities
Energy Saving<br />
All installed components are readily available on the market -<br />
throughout the world.<br />
<strong>Cisa</strong> has purposely chosen only components that are<br />
manufactured by leading multinationals with worldwide<br />
distribution networks and service centres.<br />
The hydraulic plant is entirely made of stainless steel chrome-<br />
nickel-molybdenum and insulated with silicone foam.<br />
In the design of the <strong>Cisa</strong> range of machines, a lot of attention has been dedicated to<br />
energy consumption.<br />
This is why, for example, all insulating materials are top of the range, and with generous<br />
thickness.<br />
This ensures that operating costs are kept low. Specific technical solutions have also<br />
brought the <strong>Cisa</strong> design team to implement significant savings in water usage.<br />
Each operating sterilisers which is not making any cycle, automatically it takes itself the<br />
“stand-by” position, reducing considerably in this way the consumptions.<br />
All electrics have a minimum protection requirement of IP 54.<br />
4<br />
Systems and Utilities
Safety<br />
<strong>Cisa</strong> sterilisers are designed with the most sophisticated safety<br />
procedures in mind, that take into account the hazard and<br />
risk analysis, the purpose of use, its specific class (IIa) and<br />
the necessary protection for the operator, the product and the<br />
environment.<br />
Thus, for each component there is a back up spare ready to kick<br />
in automatically in case of any problem with the first.<br />
Moreover, the process control allows the reproduction of each<br />
sterilization cycle in time.<br />
Not only do all <strong>Cisa</strong> sterilization units undergo an electromagnetic<br />
compatibility test.<br />
They are also fitted with a network filter for electromagnetic<br />
interference.<br />
Each machine in the <strong>Cisa</strong> sterilization range is entirely managed by<br />
programmable logic systems that allow for total cycle control, with a constant<br />
check on all parameters and a verification of the safety of the process.<br />
Two PLCs are interfaced with each other to ensure maximum safety of the<br />
process. While one PLC manages the machine operation, the other (with<br />
separate measurement systems) is in constant control, verifies and records<br />
the process.<br />
This allows a constant and regular sterilization cycle, without the risk of<br />
individual operator decisions.<br />
An integrated printer automatically delivers a cycle report whose layout<br />
is designed both graphically and in the wording to be easily read and<br />
interpreted. A colour touch screen monitorguides the operator through the<br />
various stages of the process, with a user-friendly interface.<br />
The machine can be supplied as a stand alone, or integrated in a global<br />
monitoring network with remote control, or in a complete sterilization control<br />
system, which includes traceability.<br />
5<br />
Control System
Industrialization<br />
<strong>Cisa</strong>’s prominent position on the market has allowed the company<br />
to develop sufficient sales volumes to ensure, for each model of the<br />
range, a production in series.<br />
The repetition of all assembly operations and the industrialisation of<br />
the manufacturing process can therefore provide a very favourable<br />
quality/cost ratio.<br />
Automation<br />
<strong>Cisa</strong> sterilization units conform to the requirements<br />
of the European Standard EN 285 and to the different<br />
Standards it refers to, amongst which are CEI EN 61010-1,<br />
CEI EN 61010-2-040, CEI EN 60204-1.<br />
The machines are also CE marked according to the CEE<br />
directive 93/42 for medical devices. Finally, they are<br />
validated according to EN 554.<br />
<strong>Cisa</strong> sterilisers can be automated to work optimally during their operative<br />
time. In fact the turn on of the autoclave, the start of the heating cycle, of the<br />
vacuum leakage test, of the Bowie & Dick test and its turn off, it may be effected<br />
automatically by itself.<br />
It is possible to automates also the material loading and unloading operations,<br />
permitting to reduce the inactivity time of the machines.<br />
Versions<br />
<strong>Cisa</strong> sterilization machines are available in<br />
various versions:<br />
•Steam<br />
units for solids or packaged porous<br />
materials (“H”)<br />
•Combined<br />
steam and formaldehyde<br />
units (“HF”)<br />
•Combined<br />
steam and liquid programme units<br />
(“HL”)<br />
The test approval of pressure vessels follows the<br />
requirements of the country of destination.<br />
6<br />
Quality and Safety Certificates<br />
•Steam<br />
units for liquids, physiological solutions,<br />
cultivation grounds, ampoules, vials and milk<br />
treatment (“LS”)<br />
•Air-steam<br />
for high pathogenic materials and<br />
virology (“LHP”)<br />
•Steam<br />
units for cages, food, liquids and<br />
stabularium material (“LS”)
TECHNICAL DATA<br />
7
CISA S.p.A. Via Pontina Km 28<br />
00040 - Pomezia - Roma - Italia<br />
Telefono +39 06 911437 1<br />
Fax +39 06 9107565<br />
e-mail: d.vendite@cisagroup.it<br />
service@cisagroup.it<br />
iyad.alamleh@cisagroup.it<br />
www.cisagroup.it<br />
Coordinamento Assistenza Tecnica<br />
+39 06 9122288<br />
CISABRASILE LTDA.<br />
Rua Dona Francisca, 8300<br />
Distrito Industrial - Bloco C- Módulo 6<br />
CEP 89239-270 - Joinville - SC Brasil<br />
Telefone +55 47 3437-9090<br />
Fax +55 47 3435-7592<br />
e-mail: cisa@cisabrasile.com.br<br />
www.cisabrasile.com.br<br />
CISA Middle East and CIS Offi ce<br />
Alsafa Wa Almarwa Building,<br />
Almadina Almonawara Street<br />
Telaa Al Ali, Amman Jordan<br />
Phone +962 6 5516592<br />
Fax +962 6 5511596<br />
e-mail: middleeast.sales@cisagroup.it<br />
P.O. Box 3692 Amman 11821 - Jordan<br />
DPL - <strong>640</strong><strong>SO</strong> - 02 - GB CISA reserves the right of modification without prior notice. The reproduction of this document is allowed if explicitly authorised by <strong>Cisa</strong> S.p.A. only.