09.11.2012 Views

Catalog Page - Platt Electric Supply

Catalog Page - Platt Electric Supply

Catalog Page - Platt Electric Supply

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

12<br />

Pump Panels<br />

Irrigation<br />

Product Family Overview<br />

Irrigation Pump Panel<br />

<strong>Catalog</strong> Number Selection<br />

Table 17. Irrigation Pump Panel <strong>Catalog</strong> Number Selection<br />

Design<br />

P = Irrigation<br />

Class<br />

54 = Type 3R Pump Panel with Disconnect<br />

55 = Type 3R Pump Panel with HMCP<br />

12 = Size 1/3R<br />

22 = Size 2/3R<br />

32 = Size 3/3R<br />

E C<br />

NEMA Size / Enclosure<br />

Product Description<br />

Cutler-Hammer ® Irrigation Pump<br />

Controllers, from Eaton’s electrical<br />

business, are combination starters<br />

designed to meet the requirements<br />

of the agricultural industry. The<br />

enclosure is UL Type 3R rated to<br />

provide weathertight protection and<br />

is available in two sizes. Irrigation<br />

application specific accessories and<br />

modifications are available to fit the<br />

customer’s requirements.<br />

The Irrigation Pump Panels use Freedom<br />

Series Motor Starting Technology<br />

to control motors up to 100 hp @ 460V.<br />

These controllers have two styles of<br />

overload protection available, interchangeable<br />

heater and solid-state<br />

overload (SSOL).<br />

P 5 4 1 2 B A B -<br />

42 = Size 4/3R<br />

52 = Size 5/3R<br />

62 = Size 6/3R<br />

Voltage<br />

A = 120V/60 or 110/50<br />

B = 240V/60 or 220/50<br />

C = 460V/60 or 440/50<br />

Cover Control<br />

A = None<br />

June 2006<br />

■ The interchangeable heater overload<br />

(C306) utilizes individual heater<br />

packs to allow customers the ability<br />

to use various heater styles.<br />

■ The solid-state overload relay provides<br />

enhanced protection and<br />

adjustment ranges as compared to<br />

bimetallic overload relays. Trip Class<br />

10 and 20 are available, along with a<br />

very wide trip current range to make<br />

setup very easy.<br />

Standards and Certifications<br />

■ UL Listed<br />

■ cUL Listed (indicates appropriate<br />

CSA Standard investigation)<br />

■ ABS Type Approval<br />

Modification Code/<br />

Relay Code<br />

Disconnect Fuse Clip Ratings<br />

A = None<br />

H = 200A/250V R<br />

B = 30A/250V R J = 200A/600V R<br />

C = 30A/600V R K = 400A/250V R<br />

D = 60A/250V R L = 400A/600V R<br />

E = 60A/600V R M = 600A/250V R<br />

F = 100A/250V R<br />

G = 100A/600V R<br />

N = 600A/600V R<br />

Breaker Ratings<br />

B = 3 Amp G = 100 Amp<br />

C = 7 Amp H = 150 Amp<br />

D = 15 Amp N = 175 Amp<br />

E = 30 Amp Q =<br />

F = 50 Amp<br />

� Thermal Magnetic Breakers.<br />

�<br />

225 Amp �<br />

For more information visit: www.Eaton<strong>Electric</strong>al.com CA05804001E


June 2006<br />

Product Selection<br />

Pump Panels<br />

Irrigation<br />

Pump Panels with Interchangeable Heater Overload<br />

Standard ECP54 controllers have a<br />

HAND/OFF/AUTO selector switch and<br />

START pushbutton mounted on the<br />

enclosure and are wired as illustrated<br />

in Figure 7.<br />

Table 18. Class ECP54 — Freedom Fusible Irrigation Pump Panels with Interchangeable Heater<br />

Overload<br />

Motor<br />

Voltage �<br />

230<br />

460<br />

—<br />

230<br />

460<br />

—<br />

230<br />

460<br />

—<br />

Starters do not include heater packs. Select 1 carton of 3 heater packs.<br />

Heater pack selection, <strong>Page</strong> 72.<br />

� Dual element fuse ratings.<br />

� Class R fuse clips.<br />

For Other Volts and Hertz Applications<br />

For other than listed volts and hertz,<br />

select required controller by <strong>Catalog</strong><br />

Number and replace the magnet coil<br />

alpha designation, 8th digit in <strong>Catalog</strong><br />

Number with proper Code Suffix from<br />

Table 19.<br />

Fuse Clips<br />

Max. hp<br />

50/60 Hz<br />

7-1/2<br />

10<br />

—<br />

15<br />

25<br />

—<br />

NEMA<br />

Size<br />

1 30<br />

30<br />

Not Installed<br />

2 60<br />

60<br />

Not Installed<br />

Table 20. C351 — Fuse Clip Selection — 3-Pole (3 Fuses)<br />

NEMA<br />

Size<br />

30<br />

50<br />

—<br />

Motor<br />

Voltage<br />

1 200/230<br />

460 – 575<br />

2 200<br />

230<br />

460 – 575<br />

3 100<br />

100<br />

Not Installed<br />

Fuse Clip Rating � Standard Width<br />

Amperes Volts <strong>Catalog</strong><br />

Number<br />

250<br />

600<br />

Not Installed<br />

250<br />

600<br />

Not Installed<br />

250<br />

600<br />

Not Installed<br />

ECP5412BAB<br />

ECP5412CAC<br />

ECP5412AAA<br />

ECP5422BAD<br />

ECP5422CAE<br />

ECP5422AAA<br />

ECP5432BAF<br />

ECP5432CAG<br />

ECP5432AAA<br />

Example: For 600V 60 Hz coil, change<br />

ECP5412BAB to ECP5412DAB<br />

Table 19. Coil Voltage<br />

Coil Volts and Hertz Suffix Code<br />

120/60 or 110/50<br />

240/60 or 220/50<br />

480/60 or 440/50<br />

600/60 or 550/50<br />

208/60<br />

Fuse Clip Rating Fuse Clip Kit for Field Installation in<br />

Non-fusible Starter<br />

Amperes Volts For Non-rejection<br />

Type Fuses<br />

<strong>Catalog</strong><br />

Number<br />

30<br />

30<br />

60<br />

60<br />

60<br />

250<br />

600<br />

250<br />

250<br />

600<br />

C351KC21<br />

C351KD22-61<br />

C351KD22-61<br />

C351KD22-61<br />

C351KD62<br />

3 200<br />

100 250 C351KE23-63<br />

C351KE23-63<br />

230<br />

100 250 C351KE23-63<br />

460 – 575 100 600 C351KE23-63<br />

� Fuse clip “R” rejection members for use with Class R fuses are supplied loose both in Fuse Clip<br />

Kits and when fuse clips are factory installed.<br />

�<br />

C351KE23-63 �<br />

C351KE23-63 �<br />

CA05804001E For more information visit: www.Eaton<strong>Electric</strong>al.com<br />

A<br />

B<br />

C<br />

D<br />

E<br />

For use with “R”<br />

Rejection Type Fuses<br />

<strong>Catalog</strong><br />

Number<br />

C351KC21R<br />

C351KD22-61R<br />

C351KD22-61R<br />

C351KD22-61R<br />

C351KD62R<br />

Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <strong>Page</strong> 4<br />

Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . <strong>Page</strong> 16<br />

Modifications Codes . . . . . . . . . . . . . . . . . . <strong>Page</strong> 73<br />

13


14<br />

Pump Panels<br />

Irrigation<br />

Pump Panels with Solid-State Overload<br />

Product Selection<br />

Table 21. Class ECP54 — Freedom Fusible Irrigation Pump Panels with Solid-State Overload<br />

Protection, Manual Reset Button and Class 20 Trip �<br />

Motor<br />

Voltage<br />

Max.<br />

hp<br />

240V 1<br />

3<br />

7-1/2<br />

10<br />

15<br />

480V 1<br />

2<br />

5<br />

10<br />

20<br />

25<br />

NEMA<br />

Size<br />

1<br />

1<br />

1<br />

2<br />

2<br />

Fuse Clip<br />

Amperes<br />

30<br />

30<br />

30<br />

60<br />

60<br />

Volts Trip<br />

Range<br />

250<br />

250<br />

250<br />

250<br />

250<br />

1.6 – 5.0<br />

3.7 – 12<br />

12 – 32<br />

12 – 37<br />

14 – 45<br />

<strong>Catalog</strong><br />

Number<br />

ECP5412BAB-R50/G84<br />

ECP5412BAB-R50/G85<br />

ECP5412BAB-R50/G86<br />

ECP5422BAD-R50/G87<br />

ECP5422BAD-R50/G88<br />

25 3 100 250 26 – 85 ECP5432BAF-R50/G89<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

30<br />

30<br />

30<br />

30<br />

60<br />

60<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

1.0 – 2.9<br />

1.6 – 5.0<br />

3.7 – 12<br />

12 – 32<br />

12 – 37<br />

14 – 45<br />

ECP5412CAC-R50/G83<br />

ECP5412CAC-R50/G84<br />

ECP5412CAC-R50/G85<br />

ECP5412CAC-R50/G86<br />

ECP5422CAE-R50/G87<br />

ECP5422CAE-R50/G88<br />

50 3 100 600 26 – 85 ECP5432CAG-R50/G89<br />

� Motor FLA based on NEC table. For Class 10, Automatic Reset and other trip ranges see<br />

Table 24.<br />

Table 22. Class ECP55 — Freedom Breaker Irrigation Pump Panels with Solid-State Overload<br />

Protection, Manual Reset Button and Class 20 Trip �<br />

Motor<br />

Voltage<br />

Max.<br />

hp<br />

240V 1<br />

3<br />

7-1/2<br />

10<br />

15<br />

NEMA<br />

Size<br />

1<br />

1<br />

1<br />

2<br />

2<br />

Breaker<br />

Rating<br />

7<br />

15<br />

30<br />

50<br />

50<br />

Trip<br />

Range<br />

1.6 – 5.0<br />

3.7 – 12<br />

12 – 32<br />

12 – 37<br />

14 – 45<br />

<strong>Catalog</strong><br />

Number<br />

ECP5512BAC-R50/G84<br />

ECP5512BAD-R50/G85<br />

ECP5512BAE-R50/G86<br />

ECP5522BAF-R50/G87<br />

ECP5522BAF-R50/G88<br />

25 3 100 26 – 85 ECP5532BAG-R50/G89<br />

50 4 150 57 – 180 ECP5542BAQ-R50/G92<br />

480V 1 1<br />

3<br />

1.0 – 2.9 ECP5512CAB-R50/G83<br />

3 1<br />

7<br />

1.6 – 5.0 ECP5512CAC-R50/G84<br />

5 1<br />

15<br />

3.7 – 12 ECP5512CAD-R50/G85<br />

10 1<br />

30<br />

12 – 32 ECP5512CAE-R50/G86<br />

10 2<br />

30<br />

12 – 37 ECP5522CAE-R50/G87<br />

25 2<br />

50<br />

14 – 45 ECP5522CAF-R50/G88<br />

50 3 100 26 – 85 ECP5532CAG-R50/G89<br />

100 4 150 57 – 180 ECP5542CAN-R50/G92<br />

� Motor FLA based on NEC table. For Class 10, Automatic Reset and other trip ranges see<br />

Table 24.<br />

Table 23. Class ECP55 — Freedom Breaker Irrigation Pump Panels with Interchangeable Heater<br />

Overload<br />

Motor<br />

Voltage<br />

Max.<br />

hp<br />

240V 1<br />

3<br />

7-1/2<br />

10<br />

15<br />

NEMA<br />

Size<br />

1<br />

1<br />

1<br />

2<br />

2<br />

Breaker<br />

Rating<br />

7<br />

15<br />

30<br />

50<br />

50<br />

<strong>Catalog</strong><br />

Number<br />

ECP5512BAC<br />

ECP5512BAD<br />

ECP5512BAE<br />

ECP5522BAF<br />

ECP5522BAF<br />

25 3 100 ECP5532BAG<br />

50 4 150 ECP5542BAQ<br />

480V 1<br />

1<br />

3<br />

ECP5512CAB<br />

3<br />

1<br />

7<br />

ECP5512CAC<br />

5<br />

1<br />

15<br />

ECP5512CAD<br />

10<br />

1<br />

30<br />

ECP5512CAE<br />

10<br />

2<br />

30<br />

ECP5522CAE<br />

25<br />

2<br />

50<br />

ECP5522CAF<br />

50 3 100 ECP5532CAG<br />

100 4 150 ECP5542CAN<br />

June 2006<br />

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . <strong>Page</strong> 16<br />

Modifications Codes. . . . . . . . . . . . . . . . . . <strong>Page</strong> 73<br />

For more information visit: www.Eaton<strong>Electric</strong>al.com CA05804001E


June 2006<br />

Relays<br />

Table 24. Freedom Solid-State Overload Relays<br />

CEP7<br />

Frame<br />

NEMA<br />

Size<br />

Pump Panels<br />

Irrigation<br />

Pump Panels with Solid-State Overload<br />

Example: R53/G144 = Class 10, 1.6 – 5.0 ampere overload for Size 0 or 1 starters.<br />

Wiring Diagram<br />

Full Load<br />

Current<br />

Adjustment<br />

Range (A)<br />

Figure 7. Typical Wiring Diagram<br />

3-Phase<br />

Manual Reset<br />

Overload<br />

3-Phase<br />

Automatic/Manual<br />

Reset<br />

Class 10 Class 20 Class 10 Class 20<br />

<strong>Catalog</strong> Number Suffix ➟ R52 R50 R53 R51<br />

M32 00 0.1 – 0.32<br />

0.32 – 1.0<br />

1.0 – 2.9<br />

1.6 – 5.0<br />

3.7 – 12<br />

0 & 1 0.1 – 0.32<br />

0.32 – 1.0<br />

1.0 – 2.9<br />

1.6 – 5.0<br />

3.7 – 12<br />

12 – 32<br />

G101<br />

G102<br />

G103<br />

G104<br />

G105<br />

G101<br />

G102<br />

G103<br />

G104<br />

G105<br />

G106<br />

G81<br />

G82<br />

G83<br />

G84<br />

G85<br />

G81<br />

G82<br />

G83<br />

G84<br />

G85<br />

G86<br />

G141<br />

G142<br />

G143<br />

G144<br />

G145<br />

G141<br />

G142<br />

G143<br />

G144<br />

G145<br />

G146<br />

G121<br />

G122<br />

G123<br />

G124<br />

G125<br />

G121<br />

G122<br />

G123<br />

G124<br />

G125<br />

G126<br />

M37 2 12 – 37 G107 G87 G147 G127<br />

M45 14 – 45 G108 G88 G148 G128<br />

M85 3 26 – 85 G109 G89 G149 G129<br />

M110 66 – 110 G110 G90 G150 G130<br />

M180 4 57 – 180 G112 G92 G152 G132<br />

M<br />

OL<br />

L1<br />

L2 L3<br />

Circuit<br />

Breaker or<br />

Motor Circ.<br />

Switch<br />

T1<br />

T2<br />

T3<br />

Motor<br />

Hand<br />

OFF<br />

Auto<br />

Pressure Switch<br />

Start M OL<br />

M<br />

CA05804001E For more information visit: www.Eaton<strong>Electric</strong>al.com<br />

15


16<br />

Pump Panels<br />

Irrigation<br />

Dimensions<br />

Dimensions<br />

Table 25. Minimum Enclosure Box Numbers<br />

Size Top Entry Bottom Entry<br />

1<br />

2<br />

2-1/2<br />

3<br />

3-1/2<br />

4<br />

HMCPE/<br />

BKR<br />

C362 Fused<br />

C362<br />

HMCPE/<br />

BKR<br />

C362 Fused<br />

C362<br />

Box No. Box No. Box No. Box No. Box No. Box No.<br />

8<br />

8<br />

8<br />

8<br />

8<br />

9<br />

SSOL Option<br />

1<br />

2<br />

2-1/2<br />

3<br />

3-1/2<br />

4<br />

8<br />

8<br />

8<br />

8 �<br />

8 �<br />

9<br />

8<br />

8<br />

8<br />

8<br />

8<br />

—<br />

8<br />

8<br />

8<br />

8 �<br />

8 �<br />

—<br />

8<br />

8<br />

8<br />

9<br />

9<br />

—<br />

8<br />

8<br />

8<br />

9<br />

9<br />

—<br />

� Irrigation pump panels with a Generation 2 solid-state overload are<br />

sized in a Box 8. Those with the Generation 1 overload are sized in a<br />

Box 9.<br />

20.02<br />

(508.5)<br />

2.63<br />

(66.8)<br />

25.50<br />

(647.7)<br />

Max.<br />

8.47<br />

(215.1)<br />

Mtg. for (4) 1/4-20 Screws<br />

14.25 (362.0) Max.<br />

9.00<br />

(228.6)<br />

9.00<br />

(228.6)<br />

3.00 3.00<br />

(76.2) (76.2)<br />

4.00<br />

(101.6)<br />

2.63<br />

(66.8)<br />

Figure 8. Box 8, Type 3R — Approximate Dimensions in Inches (mm)<br />

8<br />

8<br />

8<br />

8<br />

8<br />

9<br />

.55<br />

(14.0)<br />

8<br />

8<br />

8<br />

8 �<br />

8 �<br />

9<br />

27.50<br />

(698.5)<br />

3.50<br />

(88.9)<br />

2.04<br />

(51.8)<br />

8<br />

8<br />

8<br />

8<br />

8<br />

—<br />

8<br />

8<br />

8<br />

8 �<br />

8 �<br />

—<br />

8<br />

8<br />

8<br />

9<br />

9<br />

—<br />

8<br />

8<br />

8<br />

9<br />

9<br />

—<br />

Removable Top Cover<br />

Provides Usage of Safety<br />

Switch Hubs per Table Below<br />

29.10<br />

(739.1)<br />

Max.<br />

Plugs for<br />

Optional<br />

Flange<br />

Control<br />

3.50<br />

(88.9)<br />

9.29 (236.0)<br />

to Optional<br />

Cover Controls<br />

Concentric Knockouts for<br />

1-1/4", 1-1/2" & 2" Conduit – (2) Required<br />

Concentric Knockouts for<br />

1/2", 3/4" & 1" Conduit – (2) Required<br />

Conduit Size Cat. No.<br />

3/4" DS075H1<br />

1" DS100H1<br />

1-1/2" DS150H1<br />

2" DS200H1<br />

28.00W x 61.75H x 10.68D<br />

2.76<br />

(70.1)<br />

25.50<br />

(647.7)<br />

Max.<br />

31.14<br />

(791.0)<br />

8.41<br />

(213.6)<br />

3.50<br />

(88.9)<br />

25.50 (647.7) Max.<br />

20.00 (508.0)<br />

20.00<br />

(508.0)<br />

6.00<br />

(152.4)<br />

2.75<br />

(69.9)<br />

3.50<br />

(88.9)<br />

6.14<br />

(156.0)<br />

Mtg. for (4)<br />

1/4-20 Screws<br />

.55<br />

(14.0)<br />

29.10<br />

(739.1)<br />

Max.<br />

27.50<br />

(689.5)<br />

Concentric Knockouts for<br />

1-1/4", 1-1/2" and 2" Conduit –<br />

(2 Required)<br />

Concentric Knockouts<br />

for 1/2", 3/4" Conduit –<br />

(2 Required)<br />

3.50<br />

(88.9)<br />

Plugs for<br />

Optional<br />

Flange<br />

Control<br />

Conduit Size<br />

3/4"<br />

1"<br />

1-1/4"<br />

1-1/2"<br />

2"<br />

June 2006<br />

Removable Top Cover<br />

Provides Usage of<br />

Safety Switch Hubs<br />

per Table Below<br />

3.50<br />

(88.9)<br />

9.31 (236.5)<br />

to Optional<br />

Cover Controls<br />

Cat. No.<br />

DS075H1<br />

DS100H1<br />

DS125H1<br />

DS150H1<br />

DS200H1<br />

8.50W x 32.98H x 6.66D<br />

Figure 9. Box 9, Type 3R — Approximate Dimensions in Inches (mm)<br />

For more information visit: www.Eaton<strong>Electric</strong>al.com CA05804001E


June 2006<br />

Cover Control<br />

Non-reversing<br />

Flange Control Kits<br />

For on-the-job conversion of Type 1, 3R,<br />

4X and 12 enclosed starters. Knockouts<br />

are provided on the Type 1 flange. Type<br />

3R, 4X and 12 have prepunched holes<br />

with removable hole plugs.<br />

Factory Installed Pilot Devices<br />

To order factory installed pilot devices,<br />

change the 9th character of the<br />

<strong>Catalog</strong> Number to the alpha shown in<br />

the table below. Example: to order an<br />

ECN0514CAA with START/STOP<br />

pushbuttons and a red pilot light,<br />

change the A to a C, i.e. ECN0514CCA.<br />

Figure 10. Figure 11.<br />

Standards and Certifications<br />

■ UL Listed<br />

■ cUL Listed (indicates appropriate<br />

CSA Standard investigation)<br />

■ ABS Type Approval<br />

Dimensions<br />

Table 26. Type 1, 3R, 4X, 12 Duplex Pump<br />

Panels Non-combination<br />

NEMA Size Box No. Shipping Wt.<br />

Lbs. (kg)<br />

0 – 2 G 44 (20)<br />

3 – 4 G1 120 (54)<br />

5 – 6 F1E 405 (184)<br />

Table 27. Type 1, 3R, 4X, 12 Duplex Pump<br />

Panels Combination<br />

NEMA Size Box No. Shipping Wt.<br />

Lbs. (kg)<br />

0 – 2 H 75 (34)<br />

3 – 4 H1 180 (82)<br />

5 – 6 F1E 425 (193)<br />

Note: For Box Dimensions, see Enclosed<br />

Control Product Guide.<br />

Pump Panels<br />

Duplex Pump Panels<br />

Product Family Overview<br />

Table 28. Non-reversing Pilot Devices<br />

Description Factory Installed Flange Control Field Installation Kits<br />

Position Non- Combination Non- Combination<br />

9 Alpha combination (NEMA only) combination (NEMA only)<br />

�<br />

�<br />

�<br />

�<br />

See See<br />

See See<br />

Figure 10 Figure 11 Figure 10 Figure 11<br />

<strong>Catalog</strong> <strong>Catalog</strong><br />

Number Number<br />

No Cover Mounted Pilot Devices A<br />

■<br />

■ C400GK0<br />

START/STOP Pushbuttons B<br />

■<br />

■ C400GK1<br />

with Red RUN Pilot Light C<br />

■<br />

■ C400GK12<br />

with Red RUN/Green OFF Lights D<br />

■<br />

■<br />

�<br />

C400GK16 �<br />

—<br />

C400T1<br />

—<br />

—<br />

ON/OFF Pushbuttons<br />

E<br />

—<br />

■ —<br />

C400T2<br />

with Red RUN Pilot Light F<br />

—<br />

■ —<br />

—<br />

with Red RUN/Green OFF Lights G<br />

—<br />

■ —<br />

—<br />

HAND/OFF/AUTO Selector Switch H<br />

■<br />

■ C400GK3<br />

with Red RUN Pilot Light J<br />

■<br />

■ C400GK32<br />

with Red RUN/Green OFF Lights K<br />

■<br />

■<br />

�<br />

C400GK36 �<br />

C400T12<br />

—<br />

—<br />

START Pushbutton<br />

L<br />

—<br />

■ —<br />

ON Pushbutton<br />

M<br />

—<br />

■ —<br />

OFF Pushbutton<br />

N<br />

—<br />

■ —<br />

Red RUN Pilot Light<br />

P<br />

■<br />

■ C400GK42<br />

Green OFF<br />

Q<br />

■<br />

■<br />

Red RUN/Green OFF Pilot Lights R<br />

■<br />

■<br />

�<br />

C400GK41 �<br />

C400GK46 �<br />

C400T3<br />

C400T4<br />

C400T5<br />

C400T9 �<br />

C400T10 �<br />

C400T11 �<br />

START/STOP Selector Switch S<br />

—<br />

■ —<br />

C400T13<br />

with Red RUN Pilot Light T<br />

—<br />

■ —<br />

—<br />

with Red RUN/Green OFF Lights U<br />

—<br />

■ —<br />

—<br />

ON/OFF Selector Switch<br />

V<br />

—<br />

■ —<br />

C400T14<br />

with Red RUN Pilot Light W<br />

—<br />

■ —<br />

—<br />

with Red RUN/Green OFF Lights X<br />

—<br />

■ —<br />

—<br />

� Type 1, NEMA Sizes 00 – 4/IEC Frames A – M Non-combination ONLY.<br />

� Type 1, NEMA Sizes 5 – 9/IEC Frames N – V Non-combination PLUS all Type 3R, 4X, 12<br />

Non-combination PLUS all Combination — NEMA Sizes only.<br />

� Add Code Letter from the table below to <strong>Catalog</strong> Number for voltage — Kits only. Example:<br />

C400T9B.<br />

Rating Code Letter Rating Code Letter Rating Code Letter<br />

120V 60 Hz<br />

208V 60 Hz<br />

CA05804001E For more information visit: www.Eaton<strong>Electric</strong>al.com<br />

A<br />

E<br />

240V 60 Hz<br />

380V 50 Hz<br />

B<br />

L<br />

480V 60 Hz<br />

600V 60 Hz<br />

C<br />

D<br />

17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!