montage-anleitung - WimTec
montage-anleitung - WimTec
montage-anleitung - WimTec
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
OCEAN U6<br />
EN<br />
Adjustments<br />
B - DIP switch:<br />
Dip-switch ON OFF<br />
1 Dry out protection activated Dry out protection deactivated<br />
2 Pre-flushing activated Pre-flushing deactivated<br />
3 Pre-flushing always Pre-flushing after 5 min non-use<br />
4 Stadium mode activated Stadium mode deactivated<br />
5 Continuous flow activated Continuous flow deactivated<br />
6 --- ---<br />
With ( ) marked functions are pre-adjusted factory-made<br />
Stadium mode:<br />
At more than 3 uses within 1 1/2 min the control switches into stadium mode: only one<br />
flushing per minute will be released.<br />
Function<br />
Minimum stay time:<br />
4 s<br />
Intelligent pre-flushing:<br />
1 s, if urinal was not used for<br />
longer than 5 min<br />
Adjustable main<br />
flushing<br />
from 1 – 10 s<br />
Dry out protection:<br />
at 24 h non-use<br />
Urinal control SanTec OCEAN U6 13