OCEAN U6<br />

EN<br />

Technical specifications:<br />

Operating voltage: 230 V / 50 Hz<br />

Power consumption: approx. 3 VA<br />

Magnetic valve: cartridge 6 V<br />

Active range: Set to 50 cm by default (configurable from 30 - 70 cm)<br />

Pre-flushing: 1 s, if urinal is not used for more than 5 min<br />

Main flushing: set to 5 s by default (configurable from 1 - 15 s)<br />

Dry-out protection: automatic flushing when not in use for 24 h<br />

Flow rate: 0,08 - 0,5 MPa (0,8 - 5 bar)<br />

Static pressure: max. 0,8 MPa (8 bar)<br />

Flow rate: 0.3 - 0.7 l/s at 0.3 MPa (3 bar) acc. to EN 12541, reducible<br />

Water inlet: R 1/2“ IG<br />

Water outlet: R 1/2“ OT<br />

Noise class: I<br />

Front plate: W/H/D: 120 x 152 x 14 mm<br />

Wall mounted box: W/H/D: 128 x 122 x 85 mm<br />

Installation dimensions<br />

Dimensions in cm<br />

10-19 min 100<br />

115 (Laufen Caprino)<br />

137 (Laufen Taro Nova)<br />

51,5<br />

Zulauf<br />

DN 15<br />

Ablauf<br />

DN 50<br />

height middle sensor<br />

100 (in element<br />

approx. 100-120)<br />

Approx. 50<br />

active range<br />

65 (adults)<br />

OK-FFB<br />

OK-RFB<br />

0-25<br />

Urinal control SanTec OCEAN U6 9