MULTI [ INDOOR UNIT ]<br />
CEILING CASSETTE -4way Compact (600 X 600mm)-<br />
FDTC<br />
A<br />
CLASS<br />
FDTC 40/50/60VD<br />
Wired remote control<br />
Wireless remote control<br />
RC-E4<br />
(Option)<br />
RCH-E3<br />
(Option)<br />
RCN-TC-24W-ER<br />
(Option)<br />
SPECIFICATIONS<br />
The values are for simultaneous Multi operation.<br />
28<br />
Set model name<br />
Indoor name<br />
Outdoor name<br />
Power source<br />
Nominal cooling capacity<br />
ISO-T1(JIS)<br />
(Min~Max)<br />
Nominal heating capacity<br />
ISO-T1(JIS)<br />
(Min~Max)<br />
Input<br />
Cooling/Heating<br />
COP<br />
Cooling/Heating<br />
Energy label Cooling/Heating<br />
Inrush current (Max. running current)<br />
Indoor unit<br />
Outdoor unit<br />
Sound Ievel *1<br />
<strong>Air</strong> flow<br />
Exterior dimensions<br />
Net weight<br />
Panel<br />
<strong>Air</strong> filter, Q'ty<br />
Remote control(option)<br />
Exterior dimensions Height x Width x Depth<br />
Net weight<br />
Ref.amount precharged<br />
Ref.piping size Liquid/Gas<br />
Ref.piping length<br />
Vertical height O/U is higher<br />
Range of<br />
usage<br />
difference<br />
Operating<br />
temperature range<br />
Indoor *2<br />
Outdoor<br />
Indoor *2<br />
Outdoor<br />
Height x Width x Depth<br />
Unit+Panel<br />
O/U is lower<br />
Cooling<br />
Heating<br />
kW<br />
kW<br />
kW<br />
A 5(17)<br />
Cooling : Hi:42 Me:36 Lo:30<br />
dB(A) Heating : Hi:42 Me:36 Lo:32<br />
Cooling:51 Heating:48<br />
Cooling : Hi:11.5 Me:9 Lo:7<br />
CMM Heating : Hi:11.5 Me:9 Lo:8<br />
Cooling:60 Heating:50<br />
mm<br />
kg<br />
mm<br />
kg<br />
kg(m)<br />
ø<br />
m<br />
m<br />
m<br />
O/U<br />
O/U<br />
FDTC71VNXPVD FDTC100VNXPVD FDTC125VNXPVD FDTC140VNXTVD FDTC100VSXPVD FDTC125VSXPVD FDTC140VSXTVD<br />
Twin Triple<br />
Twin Triple<br />
FDTC40VD FDTC50VD FDTC60VD FDTC50VD FDTC50VD FDTC60VD FDTC50VD<br />
FDC71VNX FDC100VNX FDC125VNX FDC140VNX FDC100VSX FDC125VSX FDC140VSX<br />
1Phase 220-240V 50Hz, 1Phase 220V 60Hz<br />
3Phase 380-415V 50Hz, 3Phase 380V 60Hz<br />
7.1<br />
10.0<br />
12.5<br />
14.0<br />
10.0<br />
12.5<br />
14.0<br />
(3.2~8.0) (4.0~11.2) (5.0~14.0) (5.0~14.5) (4.0~11.2) (5.0~14.0) (5.0~14.5)<br />
8.0<br />
11.2<br />
14.0<br />
16.0<br />
11.2<br />
14.0<br />
16.0<br />
(3.6~9.0) (4.0~12.5) (4.0~16.0) (4.0~16.5) (4.0~12.5) (4.0~16.0) (4.0~16.5)<br />
1.99/2.18 0.0/0.0 0.0/0.0 0.0/0.0 0.0/0.0 0.0/0.0 0.0/0.0<br />
3.57/3.67 0.0/0.0 0.0/0.0 0.0/0.0 0.0/0.0 0.0/0.0 0.0/0.0<br />
A/A<br />
/<br />
A/B<br />
A/A<br />
/<br />
A/B<br />
A/A<br />
5(24)<br />
5(26)<br />
5(15)<br />
Cooling : Hi:46 Me:39 Lo:30 Cooling : Hi:42 Me:36 Lo:30 Cooling : Hi:46 Me:39 Lo:30 Cooling : Hi:42 Me:36 Lo:30<br />
Heating : Hi:46 Me:39 Lo:32 Heating : Hi:42 Me:36 Lo:32 Heating : Hi:46 Me:39 Lo:32 Heating : Hi:42 Me:36 Lo:32<br />
Cooling:48 Heating:50 Cooling:49 Heating:52<br />
Cooling:48 Heating:50 Cooling:49 Heating:52<br />
Cooling : Hi:13.5 Me:10 Lo:7 Cooling : Hi:11.5 Me:9 Lo:7 Cooling : Hi:13.5 Me:10 Lo:7 Cooling : Hi:11.5 Me:9 Lo:7<br />
Heating : Hi:13.5 Me:10 Lo:8 Heating : Hi:11.5 Me:9 Lo:8 Heating : Hi:13.5 Me:10 Lo:8 Heating : Hi:11.5 Me:9 Lo:8<br />
750x880(+88)x340<br />
60<br />
2.95(30)<br />
50<br />
-10~24<br />
100<br />
Unit:248x570x570 Panel:35x700x700<br />
18.5(Unit:15 Panel:3.5)<br />
TC-PSA-25W-E<br />
Pocket Plastic net x1 (Washable)<br />
Wired:RC-E4, RCH-E3 Wireless:RCN-TC-24W-ER<br />
1,300x970x370<br />
105<br />
4.5(30)<br />
9.52/15.88<br />
100<br />
30<br />
15<br />
-15~43* 3 -20~24<br />
The data are measured under the following conditions(ISO-T1).<br />
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.<br />
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />
*<br />
2 : The values are for one indoor unit operation.<br />
*<br />
3 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural<br />
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.<br />
Powerful-Hi can be selected. Sound level: 71/100/125VNXPVD 47dB, 100/125VSXPVD 47dB, 140VNXTVD 47dB, 140VSXTVD 47dB<br />
<strong>Air</strong> flow: 71/100/125VNXPVD 13.5CMM, 100/125VSXPVD 13.5CMM, 140VNXTVD 13.5CMM, 140VSXTVD 13.5CMM