03.01.2015 Views

Compressor - ThermaSys

Compressor - ThermaSys

Compressor - ThermaSys

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Dimensions (approximate envelope)<br />

AHP<br />

Connection Port<br />

2 places<br />

AIR<br />

FLOW<br />

Connection Port<br />

2 places<br />

AHPH<br />

Connection Port<br />

2 places<br />

AHP / AHPH<br />

Height<br />

Inlet<br />

Height<br />

AIR<br />

FLOW<br />

Outlet<br />

Connection<br />

Port<br />

2 places<br />

Width<br />

Depth<br />

Width (over brackets)<br />

Depth<br />

porT RECOMMENDED<br />

AHP AHPH CONNECTION OPTIONAL<br />

HEIGHT widTH depTH HEIGHT widTH DEPTH siZE SEPARATOR<br />

Model Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm NPT Model Number<br />

AHP(H)-400 34.20 869 26.22 666 17.96 456 19.95 507 22.45 570 17.48 444 2.00 S-600M<br />

AHP(H)-725 34.20 869 34.10 866 22.37 568 24.37 619 30.17 766 20.86 530 2.00 S-600M<br />

AHP(H)-950 36.01 915 40.78 1036 26.78 680 28.82 723 35.89 912 22.69 576 3.00 S-1700M<br />

AHP(H)-1200 36.01 915 44.73 1136 26.78 680 28.82 732 40.31 1024 24.07 611 3.00 S-1700M<br />

AHP(H)-1600 36.01 915 44.73 1136 34.89 886 36.89 937 40.31 1024 25.45 646 3.00 S-2600M<br />

AHP(H)-2000 36.01 915 54.58 1386 37.88 962 39.53 1004 48.29 1227 26.77 680 4.00 S-2600M<br />

AHP-2500 36.01 915 52.61 1336 43.70 1110 — — — — — — 4.00 S-2600M<br />

AHP-3000 36.01 915 54.58 1386 52.52 1334 — — — — — — 4.00 S-2600M<br />

AHP-3500 36.01 915 54.58 1386 56.30 1430 — — — — — — 4.00 S-2600M<br />

Motor & Fan Data<br />

approx.<br />

Full shipping Sound<br />

AIR MOTOR<br />

Fan motor load nema Thermal Weight dB(A) PSI 1 CFM 2<br />

Model CFM (CMM) HP (KW) Voltage Phase Amps Hz RPM Frame Overload Lbs. (Kg) at 3 ft (BAR) (CMM)<br />

AHP(H)-400<br />

AHP(H)-725<br />

AHP(H)-950<br />

AHP(H)-1200<br />

2200 (62.3) 1.0 (.75) 115/208-230 1 6.0 60 3450 56C No 120 (54) 97 60 (4.14) 50 (1.42)<br />

1825/2200 (51.68/62.3) 1.0 (.75) 208-230/460 3 3.6/3.2 50/60 2850/3450 56C No 120 (54) 97 60 (4.14) 50 (1.42)<br />

3600 (101.94) 1.5 (1.12) 115/208-230 1 8.5 60 3450 56C No 170 (77) 100 85 (5.86) 65 (1.84)<br />

3025/3600 (85.66/101.94) 1.5 (1.12) 208-230/460 3 4.8/4.2 50/60 2850/3450 56C No 170 (77) 100 85 (5.86) 65 (1.84)<br />

4700 (133.09) 1.5 (1.12) 115/208-230 1 8.6 60* 1740 145TC No 330 (150) 92 60 (4.14) 55 (1.56)<br />

4700 (133.09) 1.5 (1.12) 208-230/460 3 4.6 60* 1740 145TC No 330 (150) 92 60 (4.14) 55 (1.56)<br />

7000 (198.22) 5.0 (3.73) 230 1 23.0 60* 1740 184TC No 450 (204) 94 70 (4.83) 100 (2.83)<br />

7000 (198.22) 3.0 (2.24) 208-230/460 3 8.8 60* 1740 182TC No 450 (204) 94 70 (4.83) 100 (2.83)<br />

AHP(H)-1600 9700 (274.67) 5.0 (3.73) 208-230/460 3 13.4 60* 1740 184TC No 515 (234) 96 100 (6.89) 180 (5.10)<br />

AHP(H)-2000 11000 (311.49) 7.5 (5.59) 230/460 3 19.6 60* 1740 213TC No 600 (272) 98 90 (6.21) 230 (6.51)<br />

AHP-2500 14000 (396.44) 7.5 (5.59) 230/460 3 24.8 60* 1740 213TC No 625 (284) 98 90 (6.21) 230 (6.51)<br />

AHP-3000 17500 (495.54) 10.0 (7.46) 230/460 3 24.8 60* 1740 215TC No 645 (293) 102 100 (6.89) 275 (7.79)<br />

AHP-3500 17500 (495.54) 10.0 (7.46) 230/460 3 24.8 60* 1740 215TC No 750 (340) 102 100 (6.89) 275 (7.79)<br />

All motors shown are TEFC. Other motor options available upon request. Published electrical ratings are approximate, and may vary because of motor brand. Actual ratings are on motor nameplate.<br />

Fan motors must not be cycled. Outdoor applications must be protected from direct weather. If ductwork or additional static resistance is added to the cooler airstream, an auxiliary air mover<br />

may be required.<br />

*3 phase motors available in 50Hz. Reduce performance by 10%.<br />

1<br />

Air inlet to the air motor must be regulated to this pressure.<br />

2<br />

CFM (Free Air) consumption of the air motor. Lubrication = One drop of oil for every 50-75 CFM (1.42-2.12 CMM) of air going through the motor. Use detergent SAE #10 oil. Filter, regulator and lubricators<br />

for the air motors are required, but not included.