Compressor - ThermaSys
Compressor - ThermaSys
Compressor - ThermaSys
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Dimensions (approximate envelope)<br />
AHP<br />
Connection Port<br />
2 places<br />
AIR<br />
FLOW<br />
Connection Port<br />
2 places<br />
AHPH<br />
Connection Port<br />
2 places<br />
AHP / AHPH<br />
Height<br />
Inlet<br />
Height<br />
AIR<br />
FLOW<br />
Outlet<br />
Connection<br />
Port<br />
2 places<br />
Width<br />
Depth<br />
Width (over brackets)<br />
Depth<br />
porT RECOMMENDED<br />
AHP AHPH CONNECTION OPTIONAL<br />
HEIGHT widTH depTH HEIGHT widTH DEPTH siZE SEPARATOR<br />
Model Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm NPT Model Number<br />
AHP(H)-400 34.20 869 26.22 666 17.96 456 19.95 507 22.45 570 17.48 444 2.00 S-600M<br />
AHP(H)-725 34.20 869 34.10 866 22.37 568 24.37 619 30.17 766 20.86 530 2.00 S-600M<br />
AHP(H)-950 36.01 915 40.78 1036 26.78 680 28.82 723 35.89 912 22.69 576 3.00 S-1700M<br />
AHP(H)-1200 36.01 915 44.73 1136 26.78 680 28.82 732 40.31 1024 24.07 611 3.00 S-1700M<br />
AHP(H)-1600 36.01 915 44.73 1136 34.89 886 36.89 937 40.31 1024 25.45 646 3.00 S-2600M<br />
AHP(H)-2000 36.01 915 54.58 1386 37.88 962 39.53 1004 48.29 1227 26.77 680 4.00 S-2600M<br />
AHP-2500 36.01 915 52.61 1336 43.70 1110 — — — — — — 4.00 S-2600M<br />
AHP-3000 36.01 915 54.58 1386 52.52 1334 — — — — — — 4.00 S-2600M<br />
AHP-3500 36.01 915 54.58 1386 56.30 1430 — — — — — — 4.00 S-2600M<br />
Motor & Fan Data<br />
approx.<br />
Full shipping Sound<br />
AIR MOTOR<br />
Fan motor load nema Thermal Weight dB(A) PSI 1 CFM 2<br />
Model CFM (CMM) HP (KW) Voltage Phase Amps Hz RPM Frame Overload Lbs. (Kg) at 3 ft (BAR) (CMM)<br />
AHP(H)-400<br />
AHP(H)-725<br />
AHP(H)-950<br />
AHP(H)-1200<br />
2200 (62.3) 1.0 (.75) 115/208-230 1 6.0 60 3450 56C No 120 (54) 97 60 (4.14) 50 (1.42)<br />
1825/2200 (51.68/62.3) 1.0 (.75) 208-230/460 3 3.6/3.2 50/60 2850/3450 56C No 120 (54) 97 60 (4.14) 50 (1.42)<br />
3600 (101.94) 1.5 (1.12) 115/208-230 1 8.5 60 3450 56C No 170 (77) 100 85 (5.86) 65 (1.84)<br />
3025/3600 (85.66/101.94) 1.5 (1.12) 208-230/460 3 4.8/4.2 50/60 2850/3450 56C No 170 (77) 100 85 (5.86) 65 (1.84)<br />
4700 (133.09) 1.5 (1.12) 115/208-230 1 8.6 60* 1740 145TC No 330 (150) 92 60 (4.14) 55 (1.56)<br />
4700 (133.09) 1.5 (1.12) 208-230/460 3 4.6 60* 1740 145TC No 330 (150) 92 60 (4.14) 55 (1.56)<br />
7000 (198.22) 5.0 (3.73) 230 1 23.0 60* 1740 184TC No 450 (204) 94 70 (4.83) 100 (2.83)<br />
7000 (198.22) 3.0 (2.24) 208-230/460 3 8.8 60* 1740 182TC No 450 (204) 94 70 (4.83) 100 (2.83)<br />
AHP(H)-1600 9700 (274.67) 5.0 (3.73) 208-230/460 3 13.4 60* 1740 184TC No 515 (234) 96 100 (6.89) 180 (5.10)<br />
AHP(H)-2000 11000 (311.49) 7.5 (5.59) 230/460 3 19.6 60* 1740 213TC No 600 (272) 98 90 (6.21) 230 (6.51)<br />
AHP-2500 14000 (396.44) 7.5 (5.59) 230/460 3 24.8 60* 1740 213TC No 625 (284) 98 90 (6.21) 230 (6.51)<br />
AHP-3000 17500 (495.54) 10.0 (7.46) 230/460 3 24.8 60* 1740 215TC No 645 (293) 102 100 (6.89) 275 (7.79)<br />
AHP-3500 17500 (495.54) 10.0 (7.46) 230/460 3 24.8 60* 1740 215TC No 750 (340) 102 100 (6.89) 275 (7.79)<br />
All motors shown are TEFC. Other motor options available upon request. Published electrical ratings are approximate, and may vary because of motor brand. Actual ratings are on motor nameplate.<br />
Fan motors must not be cycled. Outdoor applications must be protected from direct weather. If ductwork or additional static resistance is added to the cooler airstream, an auxiliary air mover<br />
may be required.<br />
*3 phase motors available in 50Hz. Reduce performance by 10%.<br />
1<br />
Air inlet to the air motor must be regulated to this pressure.<br />
2<br />
CFM (Free Air) consumption of the air motor. Lubrication = One drop of oil for every 50-75 CFM (1.42-2.12 CMM) of air going through the motor. Use detergent SAE #10 oil. Filter, regulator and lubricators<br />
for the air motors are required, but not included.