AQUA SAFE® “The standard by which the performance of other units is compared”® AS500 5+5 & 5+75 “TRIO” ADVANCED WASTEWATER TREATMENT SYSTEM Patent Pending A L L F I B E R G L A S S C O N S T R U C T I O N AQUA SAFE - IT’S THE MANUFACTURED BY: ECOLOGICAL TANKS INC. 2247 HWY. 151 N. DOWNSVILLE, LA 71234 1-800-277-8179 www.etiaquasafe.com • aquasafe@bayou.com <strong>TOWA</strong> <strong>TOWA</strong> <strong>Insider</strong> 2
<strong>TOWA</strong> 2006 BOARD OF DIRECTORS President: Jeff Snowden Snowden On-Site, Inc. 10908 Ranch Road 2222 Austin, TX 78730 512-338-1804 phone/512-338-4475 fax jeff@snowdenonsiteseptic.com Secretary: John D. Redfern Tyler Products & Sales 10383 Spur 164 Tyler, TX 75709 903-593-8633 phone/903-593-8862 fax jdredfern@aol.com Treasurer: Wayne Peyton Clearstream <strong>Wastewater</strong> Systems, Inc. PO Box 7568 Beaumont, TX 77726 409-755-1500 phone/409-755-6500 fax waynebo@clearstreamsystems.com Immediate Past President/ President Elect: Ron Suchecki Hoot Aerobic Systems, Inc. 1237 Autumn Oak Circle China Spring, TX 76633 254-299-0821 phone/254-299-0822 fax ron@hootsystems.com Directors at Large: Rick Ashley - Lake Dallas Bret Brown - Marion Kenneth Davis - College Station William H. Hudspeth - Tomball George Johnson - Downsville, LA Bruce Lesikar - College Station Gerald Snyder - Waco Tim Snyder - Baytown Harold Stubblefi eld - San Angelo Tim N. Taylor - Nacogdoches George Witta - Elgin <strong>TOWA</strong> STAFF <strong>Texas</strong> On-Site <strong>Wastewater</strong> <strong>Association</strong> 918 Congress Avenue, Suite 200 Austin, TX 78701 512-494-1125 phone/512-494-1129 fax www.txowa.org Executive Director: Don Canada don@txowa.org <strong>Association</strong> Manager: Krista Richter krista@txowa.org Administrator: Casey Bell casey.bell@txowa.org Legal Counsel: Mark Hanna, JD mhanna@markjhanna.com 900 Congress Avenue, Suite 250 Austin, TX 78701 512-477-6200 phone/512-477-1188 fax <strong>TOWA</strong> <strong>Insider</strong> The Official <strong>Texas</strong> On-Site <strong>Wastewater</strong> <strong>Association</strong> Publication Volume 13 - Number 3 - 3rd Issue 2006 President’s Message (continued from cover) must pretreat their wastewater to 140 BOD5.” <strong>TOWA</strong> High Strength Workshop: “Home plant ATU’s are not designed for high strength, and should not be used for high strength wastewater.” “<strong>Wastewater</strong> is considered high strength if it possesses anything outside the parameters of residential strength wastewater”, which is considered to be: BOD < 300 (many say 200) mg/l FOG < no visible fi lm TSS < 300 (many say 200) mg/l pH 6.5-8.0 My recommended solution is as follows: 1. Immediately stop using inappropriate treatment products. NSF-listed units are only for residential strength wastewater applications. a. Use a high-strength treatment product or process to pretreat the wastewater, bringing the wastewater strength down to residential strength. Then, and only then, can you use 30TAC285 for the design of the balance of the OSSF. 2. For all non-residential strength applications, use the design approach presented by <strong>TOWA</strong>’s high strength wastewater workshop. a. Quantify Q by determining maximum fl ow, minimum fl ow, and average fl ow – hourly, daily, weekly, monthly, even annually (schools). b. Quantify infl uent wastewater strength parameters i. BOD, CBOD ii. TSS iii. pH iv. FOG v. Temperature c. Determine effl uent wastewater strength parameters Jeff Snowden NSF Listed Treatment Units, ONLY for Residential! d. Select a treatment and disposal process appropriate for the above conditions and for the site-specifi c conditions. 3. The Designer must state in writing the assumed infl uent Q, BOD/CBOD, TSS, pH, FOG, Temperature, and any other criteria, such as nutrients, if applicable, and must state, in writing, the effl uent values that the design is intended to achieve. 4. The Regulatory Agency must condition the permit on achieving the effl uent values required by the rules or permit. For restaurants, the renewal of the food license should be conditioned on continual compliance with the OSSF permit. <strong>TOWA</strong> <strong>TOWA</strong> <strong>Insider</strong> 3