CHEMI-SMART <br />

Chemiluminescence-Imaging Systems<br />

Creating the future together.


principle<br />

Western Blot detection using<br />

CHEMI-SMART <strong>5100</strong>.<br />

Chemiluminescence Detection<br />

Chemiluminescence has become the standard method for<br />

specific nucleic acid and protein detection. With its outstanding<br />

sensitivity this method has largely replaced imaging procedures<br />

using radioactive labels. Due to small target molecule quantities,<br />

the amount of light emitted during a <strong>chemi</strong>luminescent reaction<br />

is typically very low and its detection requires highly sensitive<br />

and specialised optics as well as optimised signal processing<br />

mechanisms to record even the faintest signals.<br />

High Sensitivity<br />

Sensitivity is the key property of a <strong>chemi</strong>luminescence system<br />

and depends on careful selection of various hardware<br />

components which must operate in perfect harmony. One<br />

important determinant of sensitivity is the quantum efficiency<br />

of the light sensor in the spectral range of <strong>chemi</strong>luminescent<br />

substrates (QE, efficiency of the transformation of light quants<br />

into electrical charge). Further important factors with impact<br />

on sensitivity are light transmittance of the camera optics as<br />

well as the distance between object and detection unit.<br />

CHEMI-SMART is a synonym for <strong>chemi</strong>luminescence imaging<br />

systems with unparalleled sensitivity thanks to perfect tuning<br />

of a multitude of factors.<br />

<strong>chemi</strong>luminescence<br />

Low Noise Level<br />

In order to benefit from high sensitivity it must go hand in hand<br />

with a minimum possible degree of background noise. Otherwise<br />

faint signals may become lost in the background rendering<br />

their detection impossible. Background noise originates mainly<br />

from two sources: by a thermally driven process spontaneously<br />

releasing electrons from conductor material and during readout<br />

of the CCD light sensor. CHEMI-SMART systems are characterised<br />

by an extraordinary low system noise level achieved by<br />

an exclusive double cooling system and continuously optimised<br />

camera electronics and readout mechanisms.<br />

Image Integrity without Compromise<br />

It is our claim to provide you with qualitative excellent image<br />

data representing a 100 % image of reality. Scientific statements<br />

should be made on the basis of unmodified raw data. The<br />

decision on type and degree of image modification and data<br />

processing should at any time be the user's. The design of our<br />

<strong>chemi</strong>luminescence imaging systems is in precise concordance<br />

with this principle.


ultimate<br />

CHEMI-SMART <strong>5100</strong><br />

CHEMI-SMART <strong>5100</strong> represents <strong>chemi</strong>luminescent imaging of the highest quality. The<br />

system represents the product of extensive practical experience in imaging technology,<br />

continuous development and uncompromising standards in the choice and tuning of its<br />

components.<br />

In vivo Luciferin Bioluminescence detection using<br />

CHEMI-SMART <strong>5100</strong>.<br />

CHEMI-SMART <strong>5100</strong> – The Ultimate Sensitivity<br />

ß Dedicated high performance <strong>chemi</strong>luminescence imaging<br />

system<br />

ß Outstanding sensitivity in the emission range of<br />

<strong>chemi</strong>luminescent substrates (QE 450nm<br />

: 70 %)<br />

ß Most precise signal quantifications thanks to true 16 bits<br />

imaging (65,536 grey levels)<br />

ß Maximum light transmittance: brightest fixed angle lens<br />

(f 0.95) and minimum object distance (< 20 cm)<br />

ß Wide dynamic range of 4.8 orders of magnitude for the<br />

documentation of strong and faint signals in the same image<br />

ß Lowest noise level through exclusive double cooling system<br />

and optimised readout mechanisms<br />

ß Absolute image integrity, unmodified raw image data for<br />

scientific analyses<br />

ß Tray-system with 6 fixed positions for different size objects<br />

ß Included imaging software with innovative image acquisition<br />

modes for excellent results in a single attempt<br />

sensitivity<br />

3<br />

4


FUSION FX7 <br />

FUSION FX7T is a multi imaging instrument designed for maximum flexibility in imaging applications. With its high sensitivity,<br />

it is perfectly suited for <strong>chemi</strong>luminescence detection. Additionally, it offers a wide range of fluorescence excitation and detection<br />

possibilities.<br />

applications<br />

FUSION FX7 – Versatile & Powerful<br />

ß Versatile in applications: Nucleic acid and protein<br />

determination with all common <strong>chemi</strong>luminescence substrates<br />

and fluorescence dyes on a variety of matrices<br />

ß Multiple fluorescence excitation modes: UV-transillumination,<br />

overhead UV illumination or STARLIGHT overhead<br />

illumination<br />

ß Outstanding sensitivity in the emission range of<br />

<strong>chemi</strong>luminescent substrates (QE 450nm<br />

: 70 %)<br />

ß Most precise signal quantifications thanks to true 16 bits<br />

Imaging (65,536 grey levels)<br />

ß Wide dynamic range of 4.8 orders of magnitude for the<br />

documentation of strong and faint signals in the same image<br />

ß Lowest noise level through exclusive double cooling system and<br />

optimised readout mechanisms<br />

ß Brightest motorised zoom lens with autofocus and motorised<br />

filter wheel<br />

ß Absolute image integrity, unmodified raw image data for<br />

scientific analyses<br />

ß Included imaging software with innovative fluorescence and<br />

<strong>chemi</strong>luminescence image acquisition modes for excellent<br />

results in a single attempt and multiplex analyses<br />

multiple<br />

Creating the future together.


innovative<br />

BIO-1D Advanced<br />

BIO-1D Advanced image analysis software is both intuitive to operate and clearly structured to<br />

work with giving outstanding functionality and innovative display options when working with<br />

<strong>chemi</strong>luminescence, bioluminescence and fluorescence images.<br />

• Qualitative and quantitative analysis of DNA/RNA and<br />

protein gels as well as blots, microtitration plates, freeform<br />

objects, agar plates and cell culture dishes<br />

• Multiple analysis options<br />

• Cutting edge analysis algorithms<br />

• 'One Button Analysis' by applying analysis templates<br />

• All tables exportable to Excel, all images and graphics can be<br />

saved as bmp files<br />

• Automatic menu navigation with the 'Next Tutorial Mode'<br />

• Unique '3D Power System ' for 3 dimensional image<br />

transformation (see adjacent figure)<br />

• Save your analysis at any time to continue later<br />

concepts<br />

STARLIGHT Overhead Illumination<br />

STARLIGHT stands for infinite possibilities of fluorescence excitation. Using high intensity LEDs a<br />

multitude of fluorescence dyes in the red, green and blue spectral range on various, intranslucent<br />

carrier matrices are effectively excited.<br />

• Strong LED excitation<br />

• Excitation maxima at 470, 528 and<br />

624 nm<br />

• Fluorescence detection on intranslucent<br />

carrier matrices<br />

• Ideally suited for multiplex imaging<br />

analysis<br />

• Compatible with CHEMI-SMART 3100<br />

and 2100<br />

Multiplex Western Blot protein detection using Qdot 565, Qdot 655<br />

and Qdot 705 dyes. Images were generated using a CHEMI-SMART <br />

3100 system.


Our Service Pledge<br />

ß Product demos, system installation and on-the-spot instruction<br />

ß Personal and professional support through our application hotline and local<br />

field representatives<br />

Ordering Information<br />

Item Description Product Code<br />

CHEMI-SMART <strong>5100</strong> Ultrasensitive dedicated high performance <strong>chemi</strong>luminescence imaging system with 60-CS5<br />

'scientific grade' Firewire ® CCD camera, brightest fixed lens, unique Peltier based<br />

double cooling system (-20 °C absolute) and tray system for precise positioning of<br />

the imaging sample<br />

FUSION FX7 Versatile high sensitivity multi-imaging <strong>chemi</strong>luminescence/fluorescence system with 60-FU-20M O<br />

'scientific grade' Firewire ® CCD camera, brightest motorised zoom lens with autofocus 60-FU-26MS*<br />

and 'lens feedback control', unique Peltier based double cooling system (-42 °C absolute), 60-FUUV-26MX**<br />

UV transilluminator (21 x 26 cm illumination area), overhead UV illumination<br />

(254 nm, 365 nm switchable) and 5 positions filter wheel<br />

BIO-1D Advanced Imaging software for sophisticated analyses with wide functional range 60-BIO-1D<br />

and unique 3D display tool for the analysis of fluorescence, <strong>chemi</strong>luminescence<br />

and bioluminescence images<br />

STARLIGHT Illumination Optional module for overhead fluorescence excitation in the visible range (RGB) with 60-STARLIGHT<br />

excitation maxima at 470 nm, 528 nm and 624 nm including filter set (3 filters)<br />

UV Conversion Screens Glass screens transforming UV to white and blue light, respectively, for the 60-FC-26WL<br />

documentation of conventionally stained protein gels (e.g. Coomassie stain, silver stain) 60-FC-26BLUE<br />

and for gentle fluorescence excitation in the blue for maximum sample preservation<br />

O<br />

with standard UV transilluminator<br />

* with SUPER-BRIGHT UV transilluminator. Contact PEQLAB for more information on SUPER-BRIGHT Illumination Technology!<br />

** with SUPER-BRIGHT UV transilluminator and UV-Epi-Illumination (Overhead UV-light (254 nm and 365 nm) for the exitation of fluorescence labled samples).<br />

Deutschland<br />

PEQLAB Biotechnologie GmbH<br />

Carl-Thiersch-Str. 2b<br />

91052 Erlangen<br />

Freecall: (D) 0800 - 100 20 16<br />

Tel: +49 (0) 9131 - 610 70 20<br />

Fax: +49 (0) 9131 - 610 70 99<br />

e-mail: info@peqlab.de<br />

Internet: www.peqlab.de<br />

Österreich<br />

PEQLAB Biotechnologie GmbH<br />

Zweigniederlassung Linz<br />

Hafenstr. 47-51<br />

4020 Linz<br />

Tel: +43 (0) 732 - 90 156 103<br />

Fax: +43 (0) 732 - 90 156 118<br />

e-mail: info@peqlab.at<br />

Internet: www.peqlab.at<br />

United Kingdom<br />

PEQLAB Ltd.<br />

25 Barnes Wallis Road<br />

Fareham PO15 5TT<br />

Freecall: (UK) 0808 - 20 21 302<br />

Tel: +44 (0) 1489 - 889 823<br />

Fax: +44 (0) 1489 - 660 040<br />

e-mail: info@peqlab.co.uk<br />

Internet: www.peqlab.co.uk<br />

V0708<br />

Creating the future together.