CHEMI-SMART <br />
Chemiluminescence-Imaging Systems<br />
Creating the future together.
principle<br />
Western Blot detection using<br />
CHEMI-SMART <strong>5100</strong>.<br />
Chemiluminescence Detection<br />
Chemiluminescence has become the standard method for<br />
specific nucleic acid and protein detection. With its outstanding<br />
sensitivity this method has largely replaced imaging procedures<br />
using radioactive labels. Due to small target molecule quantities,<br />
the amount of light emitted during a <strong>chemi</strong>luminescent reaction<br />
is typically very low and its detection requires highly sensitive<br />
and specialised optics as well as optimised signal processing<br />
mechanisms to record even the faintest signals.<br />
High Sensitivity<br />
Sensitivity is the key property of a <strong>chemi</strong>luminescence system<br />
and depends on careful selection of various hardware<br />
components which must operate in perfect harmony. One<br />
important determinant of sensitivity is the quantum efficiency<br />
of the light sensor in the spectral range of <strong>chemi</strong>luminescent<br />
substrates (QE, efficiency of the transformation of light quants<br />
into electrical charge). Further important factors with impact<br />
on sensitivity are light transmittance of the camera optics as<br />
well as the distance between object and detection unit.<br />
CHEMI-SMART is a synonym for <strong>chemi</strong>luminescence imaging<br />
systems with unparalleled sensitivity thanks to perfect tuning<br />
of a multitude of factors.<br />
<strong>chemi</strong>luminescence<br />
Low Noise Level<br />
In order to benefit from high sensitivity it must go hand in hand<br />
with a minimum possible degree of background noise. Otherwise<br />
faint signals may become lost in the background rendering<br />
their detection impossible. Background noise originates mainly<br />
from two sources: by a thermally driven process spontaneously<br />
releasing electrons from conductor material and during readout<br />
of the CCD light sensor. CHEMI-SMART systems are characterised<br />
by an extraordinary low system noise level achieved by<br />
an exclusive double cooling system and continuously optimised<br />
camera electronics and readout mechanisms.<br />
Image Integrity without Compromise<br />
It is our claim to provide you with qualitative excellent image<br />
data representing a 100 % image of reality. Scientific statements<br />
should be made on the basis of unmodified raw data. The<br />
decision on type and degree of image modification and data<br />
processing should at any time be the user's. The design of our<br />
<strong>chemi</strong>luminescence imaging systems is in precise concordance<br />
with this principle.
ultimate<br />
CHEMI-SMART <strong>5100</strong><br />
CHEMI-SMART <strong>5100</strong> represents <strong>chemi</strong>luminescent imaging of the highest quality. The<br />
system represents the product of extensive practical experience in imaging technology,<br />
continuous development and uncompromising standards in the choice and tuning of its<br />
components.<br />
In vivo Luciferin Bioluminescence detection using<br />
CHEMI-SMART <strong>5100</strong>.<br />
CHEMI-SMART <strong>5100</strong> – The Ultimate Sensitivity<br />
ß Dedicated high performance <strong>chemi</strong>luminescence imaging<br />
system<br />
ß Outstanding sensitivity in the emission range of<br />
<strong>chemi</strong>luminescent substrates (QE 450nm<br />
: 70 %)<br />
ß Most precise signal quantifications thanks to true 16 bits<br />
imaging (65,536 grey levels)<br />
ß Maximum light transmittance: brightest fixed angle lens<br />
(f 0.95) and minimum object distance (< 20 cm)<br />
ß Wide dynamic range of 4.8 orders of magnitude for the<br />
documentation of strong and faint signals in the same image<br />
ß Lowest noise level through exclusive double cooling system<br />
and optimised readout mechanisms<br />
ß Absolute image integrity, unmodified raw image data for<br />
scientific analyses<br />
ß Tray-system with 6 fixed positions for different size objects<br />
ß Included imaging software with innovative image acquisition<br />
modes for excellent results in a single attempt<br />
sensitivity<br />
3<br />
4
FUSION FX7 <br />
FUSION FX7T is a multi imaging instrument designed for maximum flexibility in imaging applications. With its high sensitivity,<br />
it is perfectly suited for <strong>chemi</strong>luminescence detection. Additionally, it offers a wide range of fluorescence excitation and detection<br />
possibilities.<br />
applications<br />
FUSION FX7 – Versatile & Powerful<br />
ß Versatile in applications: Nucleic acid and protein<br />
determination with all common <strong>chemi</strong>luminescence substrates<br />
and fluorescence dyes on a variety of matrices<br />
ß Multiple fluorescence excitation modes: UV-transillumination,<br />
overhead UV illumination or STARLIGHT overhead<br />
illumination<br />
ß Outstanding sensitivity in the emission range of<br />
<strong>chemi</strong>luminescent substrates (QE 450nm<br />
: 70 %)<br />
ß Most precise signal quantifications thanks to true 16 bits<br />
Imaging (65,536 grey levels)<br />
ß Wide dynamic range of 4.8 orders of magnitude for the<br />
documentation of strong and faint signals in the same image<br />
ß Lowest noise level through exclusive double cooling system and<br />
optimised readout mechanisms<br />
ß Brightest motorised zoom lens with autofocus and motorised<br />
filter wheel<br />
ß Absolute image integrity, unmodified raw image data for<br />
scientific analyses<br />
ß Included imaging software with innovative fluorescence and<br />
<strong>chemi</strong>luminescence image acquisition modes for excellent<br />
results in a single attempt and multiplex analyses<br />
multiple<br />
Creating the future together.
innovative<br />
BIO-1D Advanced<br />
BIO-1D Advanced image analysis software is both intuitive to operate and clearly structured to<br />
work with giving outstanding functionality and innovative display options when working with<br />
<strong>chemi</strong>luminescence, bioluminescence and fluorescence images.<br />
• Qualitative and quantitative analysis of DNA/RNA and<br />
protein gels as well as blots, microtitration plates, freeform<br />
objects, agar plates and cell culture dishes<br />
• Multiple analysis options<br />
• Cutting edge analysis algorithms<br />
• 'One Button Analysis' by applying analysis templates<br />
• All tables exportable to Excel, all images and graphics can be<br />
saved as bmp files<br />
• Automatic menu navigation with the 'Next Tutorial Mode'<br />
• Unique '3D Power System ' for 3 dimensional image<br />
transformation (see adjacent figure)<br />
• Save your analysis at any time to continue later<br />
concepts<br />
STARLIGHT Overhead Illumination<br />
STARLIGHT stands for infinite possibilities of fluorescence excitation. Using high intensity LEDs a<br />
multitude of fluorescence dyes in the red, green and blue spectral range on various, intranslucent<br />
carrier matrices are effectively excited.<br />
• Strong LED excitation<br />
• Excitation maxima at 470, 528 and<br />
624 nm<br />
• Fluorescence detection on intranslucent<br />
carrier matrices<br />
• Ideally suited for multiplex imaging<br />
analysis<br />
• Compatible with CHEMI-SMART 3100<br />
and 2100<br />
Multiplex Western Blot protein detection using Qdot 565, Qdot 655<br />
and Qdot 705 dyes. Images were generated using a CHEMI-SMART <br />
3100 system.
Our Service Pledge<br />
ß Product demos, system installation and on-the-spot instruction<br />
ß Personal and professional support through our application hotline and local<br />
field representatives<br />
Ordering Information<br />
Item Description Product Code<br />
CHEMI-SMART <strong>5100</strong> Ultrasensitive dedicated high performance <strong>chemi</strong>luminescence imaging system with 60-CS5<br />
'scientific grade' Firewire ® CCD camera, brightest fixed lens, unique Peltier based<br />
double cooling system (-20 °C absolute) and tray system for precise positioning of<br />
the imaging sample<br />
FUSION FX7 Versatile high sensitivity multi-imaging <strong>chemi</strong>luminescence/fluorescence system with 60-FU-20M O<br />
'scientific grade' Firewire ® CCD camera, brightest motorised zoom lens with autofocus 60-FU-26MS*<br />
and 'lens feedback control', unique Peltier based double cooling system (-42 °C absolute), 60-FUUV-26MX**<br />
UV transilluminator (21 x 26 cm illumination area), overhead UV illumination<br />
(254 nm, 365 nm switchable) and 5 positions filter wheel<br />
BIO-1D Advanced Imaging software for sophisticated analyses with wide functional range 60-BIO-1D<br />
and unique 3D display tool for the analysis of fluorescence, <strong>chemi</strong>luminescence<br />
and bioluminescence images<br />
STARLIGHT Illumination Optional module for overhead fluorescence excitation in the visible range (RGB) with 60-STARLIGHT<br />
excitation maxima at 470 nm, 528 nm and 624 nm including filter set (3 filters)<br />
UV Conversion Screens Glass screens transforming UV to white and blue light, respectively, for the 60-FC-26WL<br />
documentation of conventionally stained protein gels (e.g. Coomassie stain, silver stain) 60-FC-26BLUE<br />
and for gentle fluorescence excitation in the blue for maximum sample preservation<br />
O<br />
with standard UV transilluminator<br />
* with SUPER-BRIGHT UV transilluminator. Contact PEQLAB for more information on SUPER-BRIGHT Illumination Technology!<br />
** with SUPER-BRIGHT UV transilluminator and UV-Epi-Illumination (Overhead UV-light (254 nm and 365 nm) for the exitation of fluorescence labled samples).<br />
Deutschland<br />
PEQLAB Biotechnologie GmbH<br />
Carl-Thiersch-Str. 2b<br />
91052 Erlangen<br />
Freecall: (D) 0800 - 100 20 16<br />
Tel: +49 (0) 9131 - 610 70 20<br />
Fax: +49 (0) 9131 - 610 70 99<br />
e-mail: info@peqlab.de<br />
Internet: www.peqlab.de<br />
Österreich<br />
PEQLAB Biotechnologie GmbH<br />
Zweigniederlassung Linz<br />
Hafenstr. 47-51<br />
4020 Linz<br />
Tel: +43 (0) 732 - 90 156 103<br />
Fax: +43 (0) 732 - 90 156 118<br />
e-mail: info@peqlab.at<br />
Internet: www.peqlab.at<br />
United Kingdom<br />
PEQLAB Ltd.<br />
25 Barnes Wallis Road<br />
Fareham PO15 5TT<br />
Freecall: (UK) 0808 - 20 21 302<br />
Tel: +44 (0) 1489 - 889 823<br />
Fax: +44 (0) 1489 - 660 040<br />
e-mail: info@peqlab.co.uk<br />
Internet: www.peqlab.co.uk<br />
V0708<br />
Creating the future together.