06.01.2015 Views

Test, Measurement & Calibration - Rosenberger Asia Pacific

Test, Measurement & Calibration - Rosenberger Asia Pacific

Test, Measurement & Calibration - Rosenberger Asia Pacific

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Test</strong>, <strong>Measurement</strong> & <strong>Calibration</strong>


Number Designation<br />

Number Designation<br />

Nummernschlüssel<br />

03 S 1 21- 2 71 S3<br />

Plating code<br />

01-Z9 Cable Group<br />

00 Adaptors, Direct Mount<br />

0M Surface Mount Device<br />

0 Clamp Version, Accessories<br />

1 Crimp Version<br />

2 Solder Version, Solder Pot<br />

3 Solder Crimp Version<br />

4 Solder Pin, PCB Mounting<br />

5 Solid Center Contact, Coax Transition<br />

K Adaptors female (2nd end)<br />

S Adaptors male (2nd end)<br />

Successive Number<br />

1 Straight Connector<br />

2 Right Angle Connector<br />

3 T- or Y-Adapter<br />

4 Panel Connector with 4-hole Flange<br />

5 Panel Connector with Round Flange<br />

6 Panel Connector with Hexagonal Flange<br />

7 Panel Connector with 2-hole Flange<br />

A Attenuetor<br />

B Bead<br />

CK Cal Kit<br />

DC DC Block<br />

GK Gauge Kit<br />

K Female Connector, Jack<br />

KR Female Ruggedized<br />

S Male Connector, Plug<br />

P Sexless<br />

W Tool<br />

Z Accessories<br />

Connector Series (code overview see next page)<br />

Standard Plating Code<br />

Standard-Oberflächenschlüssel<br />

Outer Contact / Außenleiter<br />

Code Plating Symbol Layer thickness Magnetic Properties<br />

A Nickel Ni 3.00 μm<br />

B Silver Ag 3.00 μm Non magnetic<br />

E Gold Au 0.80 μm<br />

F Gold Au 0.10 μm<br />

H Gold selective Au 1.27 μm<br />

L AuroDur ® Au 0.15 μm Non magnetic<br />

N White bronze* Non magnetic<br />

S Stainless Steel<br />

T Tin/Lead Sn 6.00- 8.00 μm Non magnetic<br />

*White bronze (e.g.Optalloy ® ) Flash white bronze over silver (e.g. Optargen ® )<br />

Center Contact / Innenleiter<br />

Code Plating Symbol Layer thickness Magnetic Properties<br />

1 Silver Ag 3.00 μm Non magnetic<br />

3 Gold Au 1.27 μm<br />

4 Gold Au 0.80 μm<br />

5 AuroDur ® Au 0.15 μm Non magnetic<br />

Plating Code<br />

The used platings of outer and center contacts of <strong>Rosenberger</strong><br />

connectors can be identified by each part number.<br />

Example: 03 S 121 - 271 S3<br />

Plating outer contact: stainless steel (S)<br />

Plating center contact: gold (3)<br />

Oberflächenschlüssel<br />

Die verwendeten Oberflächen bei Innen- und Außenleiter<br />

der <strong>Rosenberger</strong>-Steckverbinder sind durch die beiden<br />

letzten Stellen der jeweiligen Artikel- Bestellnummer<br />

definiert.<br />

Beispiel: 03 S 121 - 271 S3<br />

Oberfläche Außenleiter: Stainless steel (S)<br />

Oberfläche Innenleiter: Gold (3)


Connector Series Code<br />

Seriencode Steckverbinder<br />

Precision Connector Series<br />

Code<br />

01 RPC-1.00 (W) - 110 GHz<br />

02 RPC-2.92 (K) - 40 GHz<br />

03 RPC-3.50 - 26.5 GHz<br />

04 RPC-SL 26.5 - 26.5 GHz<br />

05 RPC-N - 18 GHz<br />

06 RPC-TNC - 18 GHz<br />

07 RPC-7 - 18 GHz<br />

08 RPC-1.85 - 65 GHz<br />

09 RPC-2.4 (V) - 50 GHz<br />

10 RPC-SP (BMA) - 22 GHz<br />

P4 RPC-SL 40 - 40 GHz<br />

P5 RPC-N 75 Ω - 4 GHz<br />

Classical Coaxial Connector Series<br />

Code<br />

11 Tools<br />

15 Micro-RF<br />

16 FMC<br />

17 Long Wipe SMP<br />

18 Mini-SMP<br />

19 SMP<br />

20 MMCX<br />

23 Insert Mini-coax. Mini High Power<br />

24 Mini-UHF<br />

25 Insert High Voltage DIN<br />

26 FME<br />

27 IEC Antenna<br />

28 QMA<br />

29 MCX<br />

30 SSMA<br />

31 Microdot<br />

32 SMA<br />

32R SMA reverse<br />

34 1.0-2.3 DIN 47297 50 Ω<br />

35 SSMB<br />

38 SSMC<br />

39 SMC<br />

40 MCX 75 Ω<br />

41 MHV (High Voltage BNC)<br />

42 HV 4-10 (High Voltage C)<br />

43 HN (High Voltage N)<br />

45 Insert 1.0-2.3 DIN 41626 50 Ω<br />

47 SSMG<br />

48 1.6-5.6 (High Voltage)<br />

49 SMG<br />

Code<br />

50 Insert High power DIN7D-Sub<br />

51 BNC 50 Ω-4 GH<br />

51R BNC reverse<br />

52 C 50 Ω<br />

53 N 50 Ω<br />

53Q SnapN<br />

54 UHF<br />

55 D-Sub<br />

56 TNC 50 Ω<br />

56R TNC Reverse<br />

57 SHV (Safe High Voltage)<br />

59 1.8-5.6<br />

60 7-16<br />

65 4.1-9.5<br />

71 BNC 75 Ω<br />

72 C 75 Ω<br />

73 N 75 Ω<br />

74 F<br />

75 Insert 1.0-2.3 DIN 41626 75 Ω (Compatible with 50 Ω)<br />

76 TNC 75 Ω<br />

78 1.6-5.6 II. Generation<br />

81 Twinax<br />

88 1.6-5.6 III. Generation<br />

99 Specials, 99CI Controlled Impedance, 99P Pogo Pin<br />

119 P-SMP<br />

153Q QN<br />

727 IEC Antenna 75 Ω<br />

734 1.0-2.3 DIN 47297 75 Ω<br />

745 0.8-2.7 75 Ω<br />

759 SMB acc. to BT 43 75 Ω


<strong>Rosenberger</strong> Sales Worldwide<br />

<strong>Rosenberger</strong><br />

Hochfrequenztechnik GmbH & Co. KG<br />

P.O.Box 1260<br />

D-84526 Tittmoning<br />

Tel: + 49 - 86 84 -18- 0 I E-Mail: info@rosenberger.de<br />

Fax: + 49 - 86 84 -18- 499 I Web: www.rosenberger.com<br />

Germany<br />

Vertriebsbüro München<br />

Rotwandweg 5<br />

D-82024 Taufkirchen<br />

Tel: + 49 - 89 - 6 14 17 30<br />

Fax: + 49 - 89 - 6 14 09 54<br />

info@rosenberger.isar.de<br />

Vertriebsbüro Nord<br />

WI-tronik<br />

Alfred-Nobel-Straße 9<br />

D-57299 Burbach<br />

Tel: + 49 - 27 36 - 44 70 06<br />

Fax: + 49 - 27 36 - 44 70 07<br />

info@wi-tronik.de<br />

Europe<br />

Austria, Croatia,<br />

Czech Republic, Hungary,<br />

Slovakia, Slovenia<br />

Walter Krenn<br />

Hochfrequenztechnik GmbH<br />

Simmeringer Hauptstraße 421<br />

A-1110 Wien<br />

Tel: + 43 - 1 - 7 48 71 17 - 0<br />

Fax: + 43 - 1 - 7 48 71 17 - 90<br />

E-Mail: info@krenn.at<br />

Belgium, Luxembourg, Netherlands<br />

<strong>Rosenberger</strong><br />

Hochfrequenztechnik GmbH & Co. KG<br />

Sales Office Benelux<br />

Tel: + 49 - 86 84 - 18 - 0<br />

Fax: + 49 - 86 84 - 18 - 499<br />

E-Mail: info@rosenberger.de<br />

Denmark<br />

<strong>Rosenberger</strong> Danmark a/s<br />

Blokken 38, Box 92<br />

DK-3460 Birkerod<br />

Tel: + 45 - 45 82 12 94<br />

Fax: + 45 - 45 82 13 95<br />

E-Mail: mail@rosenberger.dk<br />

Finland<br />

ETRA Electronics Oy<br />

Lampputie 2<br />

FIN-00740 Helsinki<br />

Tel: + 3 58 - 2 07 65 16 0<br />

Fax: + 3 58 - 2 07 65 23 11<br />

E-Mail: electronics@etra.fi<br />

France<br />

<strong>Rosenberger</strong> France<br />

Actipark<br />

17, Rue des Frères Lumière<br />

F-67201 Eckbolsheim<br />

Tel: + 33 - 3 - 90 20 76 00<br />

Fax: + 33 - 3 - 90 20 76 01<br />

E-Mail: n_dumontel@rosenberger.de<br />

Italy<br />

<strong>Rosenberger</strong> Hochfrequenztechnik<br />

GmbH & Co. KG<br />

Sales Office Milano<br />

Tel: + 39 - 02 - 89 60 49 26<br />

Fax: + 39 - 039 - 33 05 03 93<br />

E-Mail: riccardo.santovito@rosenberger.de<br />

Norway<br />

T&G Elektro A - S<br />

Terrasseveien 6<br />

P.O. Box 63<br />

N-1321 Stabekk<br />

Tel: + 47 - 67 - 12 90 50<br />

Fax: + 47 - 67 - 12 90 60<br />

E-Mail: epost@tgelektro.no<br />

Poland<br />

PTH neopta electronics sp.z.o.o.<br />

Ul. Wlodkowica 14<br />

PL-60-334 Poznan<br />

Tel: + 48 - 61 - 6 62 48 51<br />

Fax: + 48 - 61 - 6 62 48 52<br />

E-Mail: info@neopta.pl<br />

Russia<br />

Teleconta Ltd., Moscow office<br />

Russian Federation<br />

1st Buhvostova str.<br />

12/11 OAO NPK NIIDAR<br />

bld. 17, office 118<br />

RUS-107258 Moscow<br />

Tel: + 7 - 495 - 7 39 07 20<br />

Fax: + 7 - 495 - 2 23 69 98<br />

Cell Phone: +7 - 916 - 6540839<br />

E-Mail: fiber@cyclons.ru<br />

Spain, Portugal<br />

<strong>Rosenberger</strong> Telecom, S.A.<br />

Berlin 4 - Of. 2<br />

E-28224 Pozuelo de Alarcón<br />

Tel: + 34 - 91 - 3 52 83 52<br />

Fax: + 34 - 91 - 3 52 98 13<br />

E-Mail: rosenberger@epirsa.com<br />

Sweden<br />

<strong>Rosenberger</strong> Sverige AB<br />

Båtsmansvägen 8<br />

P.O. Box 10020<br />

S-181 10 Lidingö, Stockholm<br />

Tel: + 46 - 8 - 6 36 26 00<br />

Fax: + 46 - 8 - 6 36 26 26<br />

E-Mail: info@rosenberger.se<br />

Switzerland<br />

EME AG<br />

Interconnection & Motion<br />

Lohwisstrasse 50<br />

CH-8123 Ebmatingen<br />

Tel: + 41 - 44 - 982 11 11<br />

Fax: + 41 - 44 - 982 11 33<br />

E-Mail: info@eme.ch<br />

Turkey<br />

Norana Dis Ticaret<br />

ve Mümessillik Ltd. Sti.<br />

Atatürk Caddesi 206 - 1, Derya Apt.<br />

TR-35220 Birinci Kordon, Izmir<br />

Tel: + 90 - 2 32 - 4 64 00 11<br />

Fax: + 90 - 2 32 - 4 63 06 73<br />

E-Mail: info@norana.com.tr<br />

United Kingdom<br />

<strong>Rosenberger</strong> Micro-Coax Ltd.<br />

2b Mercury House<br />

Calleva Park, Aldermaston<br />

GB-Berkshire RG7 8PN<br />

Tel: + 44 - 1-18 - 9 81 00 23<br />

Fax: + 44 - 1-18 - 9 81 61 80<br />

E-Mail: sales@rmcoax.com<br />

Africa<br />

Algeria, Morocco, Tunisia<br />

<strong>Rosenberger</strong> Telecom, S.A.<br />

Berlin 4 - Of. 2<br />

E-28224 Pozuelo de Alarcón<br />

Tel: + 34 - 91 - 3 52 83 52<br />

Fax: + 34 - 91 - 3 52 98 13<br />

E-Mail: rosenberger@epirsa.com<br />

South Africa<br />

Actum Electronics<br />

P.O. Box 819<br />

RSA-Rivonia 2128<br />

Unit A8 TheStables Business Park<br />

No 13, 3rd Road Linbro Park 2064<br />

Tel: +27 - 11 - 6 08 30 01<br />

Fax: +27 - 11 - 6 08 19 18<br />

E-Mail: sales@actum.co.za<br />

South America<br />

Argentina<br />

Mercotel S.R.L.<br />

Viel 2079<br />

RA-1424 Buenos Aires<br />

Tel: + 54 - 11 - 49 21 46 20<br />

Fax: + 54 - 11 - 49 24 59 52<br />

E-Mail: info@mercotel.com.ar<br />

Bolivia<br />

RIBCO Ltda.<br />

Ed. Cámara Nacional de Comercio<br />

Of.1002<br />

Av. Mariscal Santa Cruz Nº 1392<br />

BOL-La Paz<br />

Tel: + 591-2 -211 1100<br />

Fax: + 591-2 -233 4805<br />

E-Mail: gibatta@entelnet.bo<br />

Brazil<br />

<strong>Rosenberger</strong> Domex Telecom<br />

Rua Miracema, 781<br />

Chácaras Reunidas<br />

BR-São José dos Campos - SP<br />

CEP 12238-360<br />

Tel: + 55 - 12 - 3 35 65 00<br />

Fax: + 55 - 12 - 3 33 16 31<br />

E-Mail: vendas@rdt.com.br<br />

Chile, Latin America<br />

<strong>Rosenberger</strong> Sudamérica Ltda.<br />

Aldunate 1961,<br />

Santiago 836-1195<br />

Tel: + 56 - 2 - 3 67 11 70<br />

Fax: + 56 - 2 - 3 67 12 78<br />

E-Mail: rosenberger@rosenberger.cl<br />

Colombia<br />

Latinocomm Ltda.<br />

Diagonal 152A 34-11<br />

CO-Bogotá<br />

Tel: + 57 - 1 - 274 59 25<br />

Fax: + 57 - 1 - 216 13 52<br />

E-Mail: latinocomm@cable.net.co<br />

Guatemala, Central America<br />

Grupo Ebis<br />

11 Avenida 31-35 Zona 5<br />

GCA- Guatemala, C.A 01005<br />

Tel: + 502 - 2331 - 8700<br />

Fax: + 502 - 2332 - 7999<br />

E-Mail: info@fotusaltd.com<br />

Peru<br />

LB Forsberg<br />

Islas Virgenes 148<br />

Urb. La Portada de La Planicie,<br />

La Molina<br />

PE-Lima 12<br />

Tel: + 51 - 1 - 9977 5982<br />

Fax: + 51 - 1 - 368 1989<br />

E-Mail: forsberg1@terra.com.pe<br />

Venezuela<br />

Total Stock<br />

Centro Profesional La Urbina - P.B.<br />

Local A - Calle 3-A<br />

Urbanizacion La Urbina<br />

YV-Caracas<br />

Tel: + 58 - 212 - 241 6993<br />

Fax: + 58 - 212 - 242 3894<br />

E-Mail: totalstock@movistar.net.ve<br />

North America<br />

USA, Canada<br />

<strong>Rosenberger</strong> of North America, LLC.<br />

Greenfield Corporate Center<br />

P.O. Box 10113<br />

USA-Lancaster, PA 17605-0113<br />

Tel: + 1 - 717 - 290 8000<br />

Fax: + 1 - 717 - 399 9885<br />

E-Mail: info@rosenbergerna.com<br />

<strong>Asia</strong><br />

China, <strong>Asia</strong>, Australia<br />

<strong>Rosenberger</strong><br />

<strong>Asia</strong> <strong>Pacific</strong> Electronic Co., Ltd.<br />

No. 3, Anxiang Road, Block B<br />

Tianzhu Airport Industrial Zone<br />

Beijing 101300<br />

PR China<br />

Tel: + 86 - 10 - 80 48 19 95<br />

Fax: + 86 - 10 - 80 48 24 38<br />

E-Mail: info@rosenberger.com.cn<br />

India<br />

<strong>Rosenberger</strong> Electronic Co. (India) Pvt<br />

Limited<br />

Plot No. 263, Sector 6<br />

IMT Manesar, Gurgaon<br />

Haryana-122050<br />

Tel: + 91 - 124 - 477 55 00<br />

Fax: + 91 - 124 - 477 55 01<br />

E-Mail: rosy.gurung@rosenberger.in<br />

Israel<br />

M.T.I. Engineering Ltd.<br />

Afek Industrial Park<br />

11 Hamelacha St.<br />

IL-48091 Rosh Ha’ayin<br />

Tel: + 9 72 - 3 - 9 00 89 00<br />

Fax: + 9 72 - 3 - 9 00 89 02<br />

E-Mail: info@mti-group.co.il<br />

Japan<br />

Fusoh Shoji Co., Ltd.<br />

No. 10 - 2, 2-Chome<br />

Nagata-Cho, Chiyoda-Ku<br />

J-Tokyo 100-0014<br />

Tel: + 81 - 3 - 35 81 90 56<br />

Fax: + 81 - 3 - 35 81 57 09<br />

E-Mail: inq@fusoh.co.jp<br />

United Arabian Emirates,<br />

Gulf Region<br />

Alliance Fiwa Trading<br />

Frij Murar, Near Naif Road<br />

P.O.Box 16214<br />

16214 Dubai<br />

Tel: + 971- 42 - 732 565<br />

Fax: + 971- 42 - 732 565<br />

E-Mail: info@alliancefiwa.com<br />

Status 01.2010 I For an up-to-date overview of our sales network please refer to our website: www.rosenberger.com<br />

While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on our part and no statement herein shall be<br />

construed as recommendation to infringe existing patents.


Basics<br />

<strong>Test</strong> & <strong>Measurement</strong> Kits<br />

<strong>Test</strong> Cables & Interchangeable Port Connectors<br />

<strong>Test</strong> Devices<br />

RPC-N<br />

RPC-TNC<br />

RPC-7<br />

RPC-SP<br />

RPC-3.50<br />

RPC-2.92<br />

RPC-2.40<br />

RPC-1.85<br />

PRC-1.00<br />

Panel Piercings, Index


Contents<br />

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4<br />

Company Profile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5<br />

Quality and Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br />

VNA <strong>Calibration</strong> Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />

Physical Formulae . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

<strong>Measurement</strong> Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

<strong>Calibration</strong> Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

<strong>Calibration</strong> Kits RPC-N, 50 Ω . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

<strong>Calibration</strong> Kits RPC-N, 75 Ω . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

<strong>Calibration</strong> Kits RPC-TNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

<strong>Calibration</strong> Kits RPC-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

<strong>Calibration</strong> Kits RPC-SP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30<br />

<strong>Calibration</strong> Kits RPC-3.50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

<strong>Calibration</strong> Kits RPC-2.92 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

<strong>Calibration</strong> Kits RPC-2.40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

<strong>Calibration</strong> Kits RPC-1.85 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46<br />

<strong>Calibration</strong> Kits RPC-1.00 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50<br />

<strong>Calibration</strong> Kits 7-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<br />

<strong>Calibration</strong> Kits BNC, 50 Ω . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />

<strong>Calibration</strong> Kits F-Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

<strong>Calibration</strong> Kits QMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />

<strong>Calibration</strong> Kits SMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

<strong>Calibration</strong> Kits SnapN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70<br />

<strong>Calibration</strong> Kits FAKRA-RF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72<br />

Verification Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74<br />

Verification Kit RPC-N, 50 Ω . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74<br />

Verification Kit RPC-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75<br />

Verification Kit RPC-3.50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />

Verification Kit RPC-2.92 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77<br />

Gauge Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

Gauge Kit RPC-N, 50 Ω . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78<br />

Gauge Kit RPC-N, 75 Ω . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

Gauge Kit RPC-TNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

Gauge Kit RPC-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

Gauge Kit RPC-3.50 / RPC-2.92 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82<br />

Gauge Kit RPC-2.40 / RPC-1.85 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

Gauge Kit RPC-1.00 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84<br />

Gauge Kit 7-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85<br />

<strong>Test</strong> Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86<br />

<strong>Test</strong> Cable Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90<br />

<strong>Test</strong> Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92<br />

Interchangeable Port Connector System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

RPC-SL 26.5 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

RPC-SL 40 GHz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96<br />

2<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Contents<br />

<strong>Test</strong> Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100<br />

Open - Short - Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102<br />

Sliding Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106<br />

T-<strong>Calibration</strong>-Adaptors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108<br />

Mismatches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109<br />

Airlines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110<br />

Attenuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112<br />

Matching Attenuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118<br />

Tools, Gauges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119<br />

Precision Connectors & Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

RPC-N, 50 Ω . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124<br />

RPC-N, 75 Ω . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

RPC-TNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142<br />

RPC-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150<br />

RPC-SP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />

RPC-3.50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

RPC-2.92. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

RPC-2.40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

RPC-1.85 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202<br />

RPC-1.00 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212<br />

Panel Piercings / PCB Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220<br />

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

3


Introduction<br />

1Introduction<br />

Microwave Cables<br />

Mikrowellenkabel<br />

You can find semi rigid, hand-formable and high-performance flexible cables in catalog<br />

"Microwave & RF Cable", available from:<br />

<strong>Rosenberger</strong> Micro-Coax<br />

2b Mercury House<br />

Calleva Park, Aldermaston<br />

GB - Berkshire RG7 8PN<br />

www.rmcoax.com<br />

sales@rmcoax.com<br />

Semi-Rigid-, handformbare UTIflex- und flexible Hochleistungkabel finden Sie im<br />

Katalog "Microwave & RF Cable", erhältlich bei:<br />

<strong>Rosenberger</strong> Micro-Coax<br />

2b Mercury House<br />

Calleva Park, Aldermaston<br />

GB - Berkshire RG7 8PN<br />

www.rmcoax.com<br />

sales@rmcoax.com<br />

Attention!<br />

Achtung!<br />

The drawings of articles in catalog are not full scaled.<br />

Die Abbildungen der Artikel im Katalog sind nicht maßstäblich.<br />

Definition of Plug and Jack<br />

Definition Stecker/Kuppler<br />

The <strong>Rosenberger</strong> plug/male and jack/female designations are defined by the connector's<br />

inner contact design.<br />

This definition may derivate from other manufacturers' definitions.<br />

<strong>Rosenberger</strong> definiert die Stecker/male - Kuppler/female-Bezeichnung nach der<br />

Form des Innenleiters.<br />

Diese Definition kann von der Definition anderer Hersteller abweichen.<br />

<strong>Rosenberger</strong> Online<br />

<strong>Rosenberger</strong> im Internet<br />

Please visit also our website www.rosenberger.com, where you can find up to date<br />

product news and information.<br />

Bitte besuchen Sie auch unsere Website www.rosenberger.com, auf der wir Produktneuheiten<br />

und Ergänzungen im Produktspektrum zeitnah veröffentlichen.<br />

4<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Introduction<br />

Basics<br />

Preface<br />

Company Profile<br />

Unternehmensprofil<br />

About <strong>Rosenberger</strong><br />

<strong>Rosenberger</strong> – an Outstanding Story of Success<br />

<strong>Rosenberger</strong> - eine Erfolgsgeschichte<br />

From its humble beginnings in the year 1958 in a locksmith shop <strong>Rosenberger</strong> has<br />

developed into a worldwide operating company with an international reputation.<br />

The unique business sense and entrepreneurship of Hans (d.2007) and Katharina<br />

(d.2004) <strong>Rosenberger</strong> and, in ensuing years, the vision, management style and leadership<br />

of their three sons Hans, Bernhard and Peter lead <strong>Rosenberger</strong> to today’s<br />

prominence.<br />

For many years, the name <strong>Rosenberger</strong> has stood for future-innovative high frequency<br />

technology. Today, <strong>Rosenberger</strong> is one of the worldwide leading manufacturers<br />

of standard and customer-specific connectivity solutions in high frequency and<br />

fiber optic technology.<br />

Aus bescheidenen Anfängen im Jahre 1958 in einer kleinen Schlosserwerkstatt hat<br />

sich <strong>Rosenberger</strong> zu einem Unternehmen von Weltrang entwickelt. Aufbauend auf<br />

der einmaligen unternehmerischen Leistung von Hans (+ 2007) und Katharina <strong>Rosenberger</strong><br />

(+ 2004), haben die Söhne Hans, Bernhard und Peter das Unternehmen<br />

durch Engagement, Umsicht und Weitblick zur heutigen Größe geführt.<br />

Seit vielen Jahren werden mit dem Namen <strong>Rosenberger</strong> zukunftsweisende Hochfrequenz-Technologien<br />

verbunden. Heute ist <strong>Rosenberger</strong> ein weltweit führender Anbieter<br />

von standardisierten und kundenspezifischen Verbindungslösungen in<br />

Hochfrequenz- und Fiberoptik-Technologie.<br />

Products and Markets<br />

Produkte und Märkte<br />

The product range covers RF coaxial connectors, RF test & measurement products,<br />

RF automotive connectors as well as fiber optic products and cable assemblies. The<br />

Mobilecom Infrastructure Products business unit offers cable system solutions for<br />

radio base stations – from the antenna down to the base station. Renowned companies<br />

in high-tech industries, e.g. telecommunication, data systems, medical electronics,<br />

test & measurement, aerospace engineering or automotive electronics trust the<br />

precision and quality of <strong>Rosenberger</strong> products.<br />

<strong>Rosenberger</strong>’s custom machining center, the primary roots of the company, produces<br />

as a components system supplier (metal) components for the transmission,<br />

automotive and construction machine industries.<br />

Das Produktspektrum umfasst HF-Koaxialsteckverbinder, HF-Messtechnik-Produkte,<br />

HF-Steckverbinder für die Automobil-Elektronik sowie Fiberoptik-Produkte und Kabel-<br />

Konfektionierung. Im Bereich Mobilfunk-Infrastruktur bietet <strong>Rosenberger</strong> Systemlösungen<br />

zur Komplettverkabelung von Mobilfunkstationen - von der Antenne bis zur<br />

Basisstation. Namhafte HighTech-Unternehmen in Mobil- und Telekommunikation,<br />

Datentechnik, Medizinelektronik, industrieller Messtechnik, Luft- und Raumfahrt oder<br />

der Automobil-Elektronik setzen auf Präzision und Qualität unserer Produkte.<br />

Im Geschäftsbereich Maschinenbau, der Keimzelle des Unternehmens, bearbeitet<br />

<strong>Rosenberger</strong> als Komponenten-Systemlieferant Metallrohteile für Getriebe-, Nutzfahrzeug-<br />

und Baumaschinenhersteller.<br />

The <strong>Rosenberger</strong> Group<br />

Die <strong>Rosenberger</strong>-Gruppe<br />

The headquarters of <strong>Rosenberger</strong> is located in Fridolfing/Tittmoning (Oberbayern,<br />

Germany) where today approx. 800 people are employed. Worldwide, the <strong>Rosenberger</strong><br />

group operates 14 manufacturing and assembly locations as well as the<br />

<strong>Rosenberger</strong> sales network in Europe, <strong>Asia</strong> and North and South America where – in<br />

total – more than 3000 employees develop, produce and sell our products.<br />

In unserem Stammwerk in Fridolfing/Tittmoning sind heute rund 800 Mitarbeiter<br />

beschäftigt. In der <strong>Rosenberger</strong>-Gruppe sorgen mehr als 3000 Mitarbeiter in unserem<br />

Stammwerk, an 14 Fertigungs- und Montage-Standorten sowie den <strong>Rosenberger</strong>-Vertriebsniederlassungen<br />

in Europa, Asien sowie Nord- und Südamerika für<br />

Entwicklung, Herstellung und Verkauf unserer Produkte.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

5


Introduction<br />

Quality and Environment<br />

Superior Quality<br />

Ausgezeichnete Qualität<br />

The quality of our products and services is an essential part of our corporate strategy.<br />

<strong>Rosenberger</strong>’s quality philosophy is not just to optimize components and products,<br />

but to continuously improve and optimize all processes to ensure customer satisfaction:<br />

from product development, planning, purchasing, production, sales, logistics<br />

and service to environmental policy - all in all, to offer maximum benefit to our customers<br />

all over the world.<br />

Furthermore, our quality responsibility includes being proactive in protecting our environment<br />

and natural resources. We endeavour to avoid or minimize environmental<br />

pollution - even beyond the requirements of legal regulations whenever possible.<br />

<strong>Rosenberger</strong> is certified according to ISO/TS 16949, ISO 9001<br />

and ISO 14001.<br />

Die hohe Qualität unserer Produkte und Serviceleistungen ist ein grundlegender<br />

Bestandteil unserer Unternehmensstrategie. Die <strong>Rosenberger</strong>- Qualitätsphilosophie<br />

beinhaltet nicht nur die Optimierung aller einzelnen Produkte, sondern auch die kontinuierliche<br />

und abteilungsübergreifende Verbesserung und Optimierung aller Unternehmensprozesse:<br />

von der Produktentwicklung über Planung, Einkauf, Produktion,<br />

Vertrieb, Logistik bis hin zur Umweltpolitik – mit dem Ziel, allen unseren Kunden weltweit<br />

größtmögliche Kundenzufriedenheit zu bieten.<br />

Darüber hinaus umfasst unsere Verantwortung für Qualität auch stets umweltbewusstes<br />

Handeln und Schutz der natürlichen Ressourcen. Unser Ziel ist es, eine Verschmutzung<br />

der Umwelt zu vermeiden beziehungsweise auf ein Minimum zu<br />

beschränken – möglichst deutlich unterhalb der gesetzlich erlaubten Grenzwerte.<br />

<strong>Rosenberger</strong> ist zertifiziert nach ISO/TS 16949 und ISO 9001.<br />

Viele weitere Zertifikate, z.B. das Umwelt-Zertifikat ISO 14001, zeugen von konsequent<br />

angewandtem Qualitätsmanagement.<br />

European Environmental Directives<br />

EU-Umweltschutzrichtlinien<br />

Connectors and cable assemblies manufactured by <strong>Rosenberger</strong> correspond to the<br />

following European Directives:<br />

– 2002/95/EG – Restriction of the Use of Certain Hazardous Substances in Electrical<br />

and Electronic Equipment (RoHS)<br />

– 2002/96/EG – Waste Electrical and Electronic Equipment (WEEE)<br />

– 2003/11/EG and 2000/53/EC – End of Life Vehicle (ELV)<br />

– IEC 61760-1 - max. soldering temperature +260°C for 10 sec. for PCB connectors<br />

The objective of the above mentioned European Directives is to avoid or to limit the<br />

use of the following hazardous substances:<br />

– Lead<br />

– Mercury<br />

– Cadmium<br />

– Chrome VI<br />

– PBB (Polybrominated Biphenyls)<br />

– PBDE (Polybrominated Diphenyl Ethers)<br />

Die von <strong>Rosenberger</strong> gelieferten Steckverbinder und Kabel-Assemblies sind mit folgenden<br />

EU-Richtlinien konform:<br />

– 2002/95/EG – Restriction of the Use of Certain Hazardous Substances in Electrical<br />

and Electronic Equipment (RoHS)<br />

– 2002/96/EG – Waste Electrical and Electronic Equipment (WEEE)<br />

– 2003/11/EG und 2000/53/EC – End of Life Vehicle (ELV)<br />

– IEC 61760-1 - max. soldering temperature +260°C for 10 sec. for PCB connectors<br />

In den aufgeführten EU-Richtlinien ist die Vermeidung bzw. die Einhaltung der gesetzlichen<br />

Grenzwerte bei Einsatz folgender Stoffe geregelt:<br />

– Blei<br />

– Quecksilber<br />

– Cadmium<br />

– Chrom VI<br />

– PBB (Polybromierte Biphenyle)<br />

– PBDE (Polybromierte Diphenylether)<br />

6<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Introduction<br />

Basics<br />

<strong>Calibration</strong> Kits<br />

Vector Network Analyzer (VNA) <strong>Calibration</strong> Methods<br />

Vektorielle Netzwerkanalysatoren (VNA) – Kalibrierverfahren<br />

All calibration methods are based on simple standards for which scattering parameters<br />

are well predictable. The number and type of standards, and the number of<br />

required reference procedures varies widely. The following paragraphs summarize<br />

some of the most common techniques.<br />

TMSO<br />

The most basic and widely used one-port calibration technique is the MSO (Matched<br />

Load/Short/Open) calibration. The most common two-port calibration technique is<br />

the TMSO (Thru/Match/Short/Open) calibration. These techniques are fast and operationally<br />

simple, and are satisfactory for socalled “insertable devices” and cursory<br />

measurements of non-insertables. The reference plane after calibration is equal to the<br />

connector reference plane. Realizing ideal open circuit and load terminations, particularly<br />

over broadband, is problematic. For improved accuracy at higher frequencies, a<br />

sliding load can be used instead of the matched load. MSO is also called OSL (Open/<br />

Short/Load) and TMSO is also called SOLT (Short/Open/Load/Thru) in other papers.<br />

TSD<br />

It is possible to circumvent the difficulty of constructing opens and loads. To the<br />

remaining Thru and Short standards, an unknown length of precision non-reflecting<br />

transmission line is added to create a Delay-Standard (TSD). An accurate error model<br />

is a key feature of the technique [1].<br />

TRL<br />

Engen and Hoer [2] presented a technique replacing the need for a standard Short<br />

circuit termination with an unknown non-zero Reflecting termination. They also<br />

renamed the Delay standard to Line, thus the acronym, TRL. Although a nominal<br />

short circuit is the natural choice for the reflect standard, the actual magnitude of its<br />

reflection coefficient need not be known. As with the TSD technique, the length of the<br />

line standard need not be known. In addition, it does not have to be assumed lossless.<br />

LRL<br />

If the Thru standard is replaced by a second Line standard of different electrical<br />

length than the first, the resulting calibration method is the so-called "LRL". The<br />

advantage of LRL calibration is that S-Parameters can be acquired accurately using<br />

any (repeatable) combination of connectors at the measurement ports due to the<br />

non-zero length of the lines. That means that not only male-female port configurations<br />

are possible but also male-male and female-female arrangements can be supported<br />

[3]. When the length of line 1 is zero, LRL becomes TRL.<br />

LRM<br />

It is sometimes advantageous to substitute a Matched Load for the second Line. The<br />

match standard must be an excellent broadband termination, although the Reflection<br />

standard need only be repeatable. The LRM technique is chiefly used in conjunction<br />

with wafer probes for measuring semiconductor characteristics. When the length of<br />

the first line is zero, LRM becomes TRM.<br />

Je nach Anforderung sind unterschiedliche Kalibrierverfahren erarbeitet worden, die<br />

nach Art und Anzahl der Kalibrierstandards differieren. Die Streuparameter der Standards<br />

sollten sich möglichst gut beschreiben lassen. Einige Verfahren erlauben<br />

jedoch auch den Einsatz von teilweise unbekannten Standards. Es folgt eine Zusammenfassung<br />

der gängigsten Verfahren.<br />

TMSO<br />

Das grundlegende, am häufigsten eingesetzte Eintor-Kalibrierverfahren heisst MSO<br />

(Match, Short, Open). Das gebräuchlichste Zweitor-Kalibrierverfahren nennt man<br />

TMSO (Thru, Match, Short, Open). Diese Verfahren sind schnell und vom Ablauf her<br />

einfach. Die Bezugsebene nach dem Kalibrieren ist gleich der Referenzebene der<br />

Steckverbindung. Die Herstellung breitbandiger, idealer Leerlauf- und Lastabschlüsse<br />

kann aber problematisch sein. Um erhöhte Genauigkeit bei höheren Frequenzen zu<br />

erzielen, kann eine Gleitlast anstelle eines Abschlusswiderstands verwendet werden.<br />

MSO nennt man übrigens auch OSL (Open, Short, Load), und TMSO bezeichnet<br />

man in einigen Veröffentlichungen als SOLT (Short, Open, Load, Thru).<br />

TSD<br />

Die Schwierigkeiten bei der Herstellung von Leerläufen und Lastabschlüssen lassen<br />

sich umgehen. Zu den Thru- und Short-Standards fügt man eine reflexionsfreie Übertragungsleitung<br />

unbekannter Länge hinzu und schafft somit einen Delay-Standard.<br />

Ein Hauptmerkmal dieses Verfahrens ist das genaue Fehlermodell [1].<br />

TRL<br />

Engen und Hoer [2] stellten ein Verfahren vor, das den sonst erforderlichen Short<br />

(Kurzschluss) durch eine unbekannte Reflexion mit einem Reflexionsfaktor abweichend<br />

von 0 ersetzt. Sie benannten zudem Delay (Verzögerung) in Line (Leitung) um,<br />

daher die Abkürzung TRL (Thru, Reflexion, Line). Obwohl ein Kurzschluss die natürliche<br />

Wahl für die Reflexionsnorm darstellt, ist es nicht erforderlich, den eigentlichen<br />

Betrag des Reflexionsfaktors zu kennen. Wie beim TSD-Verfahren braucht die Länge<br />

der Leitung nicht bekannt zu sein. Zudem muss sie nicht als verlustlos angenommen<br />

werden.<br />

LRL<br />

Ersetzt man den Thru-Standard durch einen zweiten Line-Standard, dessen elektrische<br />

Länge anders als die der ersten Leitung ist, ergibt sich das Kalibrierverfahren<br />

LRL. Der Vorteil dieses Verfahrens besteht darin, dass sich Streuparameter wegen<br />

der Länge der Leitungen (ungleich 0) mit jeder (wiederholbaren) Kombination der<br />

Anschlüsse an den Messtoren genau erfassen lassen. Somit sind nicht nur Stecker/<br />

Buchse- sondern auch Stecker/Stecker- und Buchse/Buchse-Konfigurationen möglich<br />

[3]. Ist die Länge der Leitung 1 gleich 0, wird LRL zu TRL.<br />

LRM<br />

Manchmal ist es vorteilhaft, die zweite Leitung durch einen Abschlusswiderstand zu<br />

ersetzen. Der Match-Standard muss einen exzellenten breitbandigen Abschluss darstellen,<br />

obgleich der Reflexions-Standard nur wiederholbar zu sein hat. Das LRM-Verfahren<br />

wird hauptsächlich zur Messung von planaren Schaltungen zusammen mit<br />

Prüfspitzen eingesetzt. Ist die Länge der ersten Leitung gleich 0, wird LRM zu TRM.<br />

References<br />

[1] FRANZEN, N.R., SPECIALE, R.A., Accurate Scattering Parameter <strong>Measurement</strong>s<br />

on Nonconnectable Microwave Networks, Proc. 6th European Microwave Conference,<br />

September 1976, pp. 210–214<br />

[2] ENGEN, G.F., HOER, C.A., Thru-Reflect-Line: An Improved Technique for Calibrating<br />

the Dual Six Port Automatic Network Analyzer, IEEE Trans. Microwave Theory<br />

Tech., MTT-27, Dec. 1979, pp. 987–993<br />

[3] HOER, C.A., ENGEN, G.F., Calibrating a Dual Six-Port or Four-Port for Measuring<br />

Two-Ports with Any Connectors, IEEE MTT-S, Symposium Digest 1986, pp. 665–<br />

668<br />

[4] AGILENT TECHNOLOGIES, Applying the 8510 TRL <strong>Calibration</strong> for Non-Coaxial<br />

<strong>Measurement</strong>s, Product Note 8510–8A, May 2001<br />

[5] HEUERMANN, H., Save Network Analyzer <strong>Calibration</strong> Procedures for Coaxial and<br />

Planar Wave-Guides, Doctoral Thesis, University Bochum 12/1995<br />

[6] AGILENT TECHNOLOGIES, Applying Error Correction to Network Analyzer <strong>Measurement</strong>s,<br />

Application Note 1287–3<br />

[7] AGILENT TECHNOLOGIES, Network Analyzer Basics, Seminar Paper<br />

[8] INGALLS, M., Vector Network Analyzer <strong>Measurement</strong>s, Internet Page,<br />

04.11.1998<br />

[9] Hiebel, Michael. Grundlagen der vektoriellen Netzwerkanalyse. Rohde & Schwarz.<br />

2. Auflage. 2007<br />

Literatur<br />

[1] Franzen, N.R., Speciale, R.A.: Accurate Scattering Parameter <strong>Measurement</strong>s on<br />

Nonconnectable Microwave Networks. Proc. 6th European Microwave Conference,<br />

09/1976, S. 210–214<br />

[2] Engen, G.F., Hoer, C.A.: Thru-Reflect-Line – An Improved Technique for Calibrating<br />

the Dual Six Port Automatic Network Analyzer. IEEE Trans. Microwave Theory<br />

Tech., MTT-27, 12/1979, S. 987–993<br />

[3] Hoer, C.A., Engen, G.F.: Calibrating a Dual Six-Port or Four-Port for Measuring<br />

Two-Ports with Any Connectors. IEEE MTT-S, Symposium Digest 1986, S. 665–668<br />

[4] Agilent Technologies: Applying the 8510 TRL <strong>Calibration</strong> for Non-Coaxial <strong>Measurement</strong>s.<br />

Produktblatt 8510–8A, 05/2001<br />

[5] Heuermann, H.: Save Network Analyzer <strong>Calibration</strong> Procedures for Coaxial and<br />

Planar Waveguides. Dissertation, Universität Bochum, 12/1995<br />

[6] Agilent Technologies: Applying Error Correction to Network Analyzer <strong>Measurement</strong>s.<br />

Applikationsblatt 1287–3<br />

[7] Agilent Technologies: Network Analyzer Basics. Seminarunterlagen<br />

[8] Ingalls, M.: Vector Network Analyzer <strong>Measurement</strong>s. Internetseite, 04.11/1998<br />

[9] Hiebel, Michael. Grundlagen der vektoriellen Netzwerkanalyse. Rohde & Schwarz.<br />

2. Auflage. 2007<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

7


Introduction<br />

2Introduction<br />

Physical Formulae<br />

Physical Constants | Physikalische Konstanten<br />

µ 0 =4π·10 –7 Vs/Am = 12.566370614·10 –7 H/m<br />

ε 0 = 8.854187817·10 –12 As/Vm<br />

1<br />

--------------<br />

c 0 =<br />

ε<br />

= 2.99792458·10 8 m/s ≈ 3·10 8 m/s<br />

0 ⋅ μ 0<br />

μ<br />

Z F = ---- 0<br />

= 376.730313461 Ω ≈ 120 πΩ<br />

ε 0<br />

π<br />

e<br />

= 3.141592653590…<br />

= 2.718281828459…<br />

Microwave Equations | Mikrowellen-Gleichungen<br />

1 μ<br />

Z coax = ----<br />

0 ⋅ μ r D<br />

⋅ ----------- ⋅ ln-- ≈<br />

2π ε 0<br />

⋅ ε d r<br />

60 D<br />

------ ⋅ ln --<br />

d<br />

ε r<br />

Γ =<br />

Z L – Z<br />

------------- 0<br />

Z L + Z 0<br />

T<br />

RL<br />

IL<br />

= exp(–γ·l)<br />

= –20·log 10 |Γ|<br />

= –20·log 10 |T|<br />

ML = –10·log 10 (1–|Γ| 2 )<br />

VSWR =<br />

1 + Γ<br />

------------<br />

1 – Γ<br />

Legend<br />

Description | Beschreibung<br />

µ 0 Magnetic constant | Magnetische Feldkonstante<br />

ε 0<br />

c 0<br />

Z F<br />

Z 0<br />

Z L<br />

Z coax<br />

D<br />

d<br />

G<br />

T<br />

γ<br />

RL<br />

IL<br />

ML<br />

VSWR<br />

Electric constant | Elektrische Feldkonstante<br />

Speed of light in vacuumt | Lichtgeschwindigkeit<br />

Wave impedance in vacuumt | Feldwellenwiderstand<br />

Characteristic line impedancet | Wellenwiderstand der Leitung<br />

Load impedancet | Wellenwiderstand des Abschlusses<br />

Characteristic impedance coaxial linet | Wellenwiderstand Koaxialleitung<br />

Outer conductor diametert | Durchmesser Außenleiter<br />

Center conductor diametert | Durchmesser Innenleiter<br />

Reflection coefficientt | Reflexionskoeffizient<br />

Transmission coefficientt | Transmissionskoeffizient<br />

Propagation constantt | Ausbreitungskonstante<br />

Return losst | Reflexionsdämpfung<br />

Insertion losst | Einfügedämpfung<br />

Mismatch losst | Dämpfung durch Fehlanpassung<br />

Standing wave ratiot | Stehwellenverhältnis<br />

8<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Introduction<br />

Basics<br />

<strong>Measurement</strong> Chart<br />

VSWR<br />

Reflection<br />

Coefficient<br />

Return Loss<br />

= Ref.<br />

X<br />

Below Ref.<br />

Ref. + X<br />

Ref. – X<br />

Peak to Peak<br />

Ripple<br />

Maximum<br />

Phase Uncertainty<br />

±<br />

Mismatch<br />

Loss<br />

in dB in dB in dB in dB in dB in Degrees in dB<br />

17,3910 0,8913 1 1 –5,535 19,271 24,806 63,031 6,8683<br />

8,7242 0,7943 2 2 –5,078 13,737 18,815 52,592 4,3292<br />

5,8480 0,7079 3 3 –4,649 10,691 15,340 45,068 3,0206<br />

4,4194 0,6310 4 4 –4,249 8,658 12,907 39,121 2,2048<br />

3,5698 0,5623 5 5 –3,876 7,177 11,053 34,218 1,6509<br />

3,0095 0,5012 6 6 –3,529 6,041 9,570 30,079 1,2563<br />

2,6146 0,4467 7 7 –3,207 5,141 8,348 26,531 0,9665<br />

2,3229 0,3981 8 8 –2,911 4,410 7,320 23,460 0,7494<br />

2,0999 0,3548 9 9 –2,638 3,806 6,444 20,782 0,5844<br />

1,9250 0,3162 10 10 –2,387 3,302 5,688 18,435 0,4576<br />

1,7849 0,2818 11 11 –2,157 2,876 5,032 16,370 0,3594<br />

1,6709 0,2512 12 12 –1,946 2,513 4,459 14,548 0,2830<br />

1,5769 0,2239 13 13 –1,755 2,201 3,956 12,937 0,2233<br />

1,4985 0,1995 14 14 –1,580 1,933 3,513 11,509 0,1764<br />

1,4326 0,1778 15 15 –1,422 1,701 3,122 10,243 0,1396<br />

1,3767 0,1585 16 16 –1,278 1,499 2,777 9,119 0,1105<br />

1,3290 0,1413 17 17 –1,148 1,323 2,470 8,120 0,0875<br />

1,2880 0,1259 18 18 –1,030 1,169 2,199 7,232 0,0694<br />

1,2528 0,1122 19 19 –0,924 1,034 1,957 6,442 0,0550<br />

1,2222 0,1000 20 20 –0,828 0,915 1,743 5,739 0,0436<br />

1,1957 0,0891 21 21 –0,742 0,811 1,552 5,113 0,0346<br />

1,1726 0,0794 22 22 –0,664 0,719 1,383 4,556 0,0275<br />

1,1524 0,0708 23 23 –0,594 0,638 1,232 4,060 0,0218<br />

1,1347 0,0631 24 24 –0,531 0,566 1,098 3,618 0,0173<br />

1,1192 0,0562 25 25 –0,475 0,503 0,978 3,224 0,0138<br />

1,1055 0,0501 26 26 –0,425 0,447 0,871 2,873 0,0109<br />

1,0935 0,0447 27 27 –0,380 0,397 0,776 2,560 0,0087<br />

1,0829 0,0398 28 28 –0,339 0,353 0,692 2,282 0,0069<br />

1,0736 0,0355 29 29 –0,303 0,314 0,617 2,033 0,0055<br />

1,0653 0,0316 30 30 –0,270 0,279 0,550 1,812 0,0043<br />

1,0580 0,0282 31 31 –0,241 0,248 0,490 1,615 0,0035<br />

1,0515 0,0251 32 32 –0,215 0,221 0,436 1,439 0,0027<br />

1,0458 0,0224 33 33 –0,192 0,197 0,389 1,283 0,0022<br />

1,0407 0,0200 34 34 –0,172 0,175 0,347 1,143 0,0017<br />

1,0362 0,0178 35 35 –0,153 0,156 0,309 1,019 0,0014<br />

1,0322 0,0158 36 36 –0,137 0,139 0,275 0,908 0,0011<br />

1,0287 0,0141 37 37 –0,122 0,124 0,245 0,809 0,0009<br />

1,0255 0,0126 38 38 –0,109 0,110 0,219 0,721 0,0007<br />

1,0227 0,0112 39 39 –0,097 0,098 0,195 0,643 0,0005<br />

1,0202 0,0100 40 40 –0,086 0,087 0,174 0,573 0,0004<br />

1,0180 0,0089 41 41 –0,077 0,078 0,155 0,511 0,0003<br />

1,0160 0,0079 42 42 –0,069 0,069 0,138 0,455 0,0003<br />

1,0143 0,0071 43 43 –0,061 0,062 0,123 0,406 0,0002<br />

1,0127 0,0063 44 44 –0,055 0,055 0,110 0,362 0,0002<br />

1,0113 0,0056 45 45 –0,049 0,049 0,098 0,322 0,0001<br />

1,0101 0,0050 46 46 –0,043 0,044 0,087 0,287 0,0001<br />

1,0090 0,0045 47 47 –0,039 0,039 0,078 0,256 0,0001<br />

1,0080 0,0040 48 48 –0,035 0,035 0,069 0,228 0,0001<br />

1,0071 0,0035 49 49 –0,031 0,031 0,062 0,203 0,0001<br />

1,0063 0,0032 50 50 –0,027 0,028 0,055 0,181 0,0000<br />

1,0036 0,0018 55 55 –0,015 0,015 0,031 0,102 0,0000<br />

1,0020 0,0010 60 60 –0,009 0,009 0,017 0,057 0,0000<br />

1,0006 0,0003 70 70 –0,003 0,003 0,005 0,018 0,0000<br />

1,0002 0,0001 80 80 –0,001 0,001 0,002 0,006 0,0000<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

9


<strong>Rosenberger</strong> offers a wide range of calibration kits for a variety of<br />

standard coaxial test interfaces. The following types are available:<br />

Full versions including adaptors and sliding loads for variable<br />

measurements, industrial kits for standard measurements as well<br />

as LRL and TRL calibration kits.<br />

Für eine Vielzahl von Standard-Koaxial-Interfaces bietet <strong>Rosenberger</strong><br />

ein umfassendes Spektrum an Kalibrier-Kits. Folgende<br />

Versionen werden angeboten: „Full“-Versionen mit Adaptern<br />

und Gleitlasten für variable Messaufbauten, „Industrial“-Kits<br />

für Standardmessungen sowie LRL- und TRL-Kalibrier-Kits.<br />

The product range includes also verification kits for RPC-N, RPC-7,<br />

RPC-3.50 and RPC-2.92 series, as well as gauge kits for various<br />

standard coaxial interfaces.<br />

Das Produktspektrum wird ergänzt durch Verifizier-Kits für<br />

die Serien RPC-N, RPC-7, RPC-3.50 und RPC-2.92 sowie<br />

Messuhren-Kits (Gauge Kits) für verschiedene Koaxial-<br />

Steckverbinder-Serien.


<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

<strong>Test</strong> & <strong>Measurement</strong> Kits<br />

Features<br />

<strong>Calibration</strong> Kits<br />

Verification Kits<br />

Gauge Kits


<strong>Test</strong> & <strong>Measurement</strong> Kits<br />

1<strong>Test</strong> & <strong>Measurement</strong> Kits<br />

Vector Network Analyzer (VNA)<br />

Vektorielle Netzwerkanalysatoren (VNA)<br />

Network analyzers (NAs) are important tools in the development of microwave circuits<br />

and systems and gain increasing importance in industrial measurement applications.<br />

Vector network analyzers (VNAs) are of particular interest due to their capability of<br />

being calibrated.<br />

Vector-error correction is the process of characterizing systematic errors of the measurement<br />

system by measuring known calibration standards, and then removing the<br />

effects of these errors from subsequent measurements. The quality of the calibration<br />

depends on operator experience and random effects such as system sensitivity limits,<br />

noise, connection repeatibility, etc. The quality of the standards is the crucial factor<br />

with regard to the accuracy of the error correction.<br />

For a number of coaxial standard test interfaces <strong>Rosenberger</strong> offers the following<br />

types of calibration kits:<br />

– Full version with adaptors and sliding loads for variable measurements<br />

– Industrial version for standard measurements<br />

– LRL and TRL calibration kits<br />

All <strong>Rosenberger</strong> <strong>Calibration</strong> Kits can be used from DC to their maximum frequency.<br />

The following tables shows the complete range of available <strong>Rosenberger</strong> calibration,<br />

verification and gauge kits.<br />

Netzwerkanalysatoren (NA) stellen wichtige Hilfsmittel bei der Entwicklung von Mikrowellenschaltungen<br />

und -systemen dar, und werden auch zunehmend für industrielle<br />

Messungen in der Fertigung und Qualitätssicherung von Bedeutung. Vektorielle Netzwerkanalysatoren<br />

(VNA) sind wegen ihrer Kalibrierfähigkeit von besonderem Interesse.<br />

Die vektorielle Fehlerkorrektur ist ein Verfahren, bei dem die Systemfehler der Messeinrichtung<br />

durch Kalibriermessungen mit bekannten Kalibrierstandards ermittelt werden.<br />

Sie können dann bei nachfolgenden Messungen korrigiert werden. Die Güte des<br />

Kalibrierens hängt von der Erfahrung der Bedienperson und stochastischen Einflüssen<br />

wie z.B. Drift über Temperatur und Zeit, Rauschen im Generator- und Empfängerteil<br />

und der Reproduzierbarkeit der verwendeten Steckverbindungen ab. Die<br />

Qualität der Kalibrierstandards ist entscheidend im Hinblick auf die Genauigkeit der<br />

Fehlerkorrektur.<br />

<strong>Rosenberger</strong> bietet für eine Reihe von Koaxial-Steckverbinder-Serien folgende Kalibrier-Kits:<br />

– Full-Version mit Adaptern und Gleitlasten für sehr variable Messaufbauten<br />

– Industrial-Version für Standard-Messungen<br />

– LRL- und TRL-Kalbrier-Kits<br />

Sämtliche Kalibrier-Kits von <strong>Rosenberger</strong> sind ab DC einsetzbar.<br />

Folgende Tabellen geben Ihnen einen Überblick über alle verfügbaren Kalibrier-, Verfizier-<br />

und Messuhren-Kits.<br />

12<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> & <strong>Measurement</strong> Kits<br />

Coaxial <strong>Calibration</strong> Kits<br />

Connector Series |<br />

Steckverbinder-Serie<br />

Frequency Range |<br />

Frequenzbereich<br />

Ordering Number<br />

Full<br />

Ordering Number<br />

Industrial<br />

Ordering Number<br />

LRL/TRL<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

RPC-N, 50 Ω DC-18.0 GHz 05 CK 100-150 05 CK 10A-150 05 CK 120-150<br />

RPC-N, 75 Ω DC-4.0 GHz P5 CK 100-170 P5 CK 10A-170 P5 CK 120-170 (TRL)<br />

RPC-TNC DC-18.0 GHz 06 CK 100-150 06 CK 10A-150 -<br />

RPC-7 DC-18.0 GHz 07 CK 100-150 07 CK 10A-150 07 CK 120-150<br />

RPC-SP (BMA) DC-22.0 GHz 10 CK 100-150 - 10 CK 120-150 (TRL)<br />

RPC-3.50 DC-26.5 GHz 03 CK 100-150 03 CK 10A-150 03 CK 120-150<br />

RPC-2.92 DC-40.0 GHz 02 CK 100-150 02 CK 10A-150 02 CK 120-150<br />

RPC-2.40 DC-50.0 GHz 09 CK 100-150 09 CK 10A-150 09 CK 120-150<br />

RPC-1.85 DC-65.0 GHz 08 CK 100-150 08 CK 10A-150 08 CK 120-150<br />

RPC-1.00 DC-110.0 GHz - - 01 CK 120-150<br />

7-16 DC-8.0 GHz 60 CK 100-150 60 CK 10A-150 60 CK 120-170<br />

BNC, 50 Ω DC-4.0 GHz 51 CK 100-150 51 CK 10A-150 -<br />

F DC-4.0 GHz 74 CK 100-170 74 CK 10A-170 74 CK 120-170 (TRL)<br />

QMA DC-18.0 GHz 28 CK 100-150 - -<br />

SMP DC-18.0 GHz - 19 CK 10A-150 -<br />

SnapN DC-11.0 GHz - 53 CK 10A-150 -<br />

FAKRA-RF DC-6.0 GHz 59 CK 100-150 - -<br />

Verification Kits<br />

Connector Series |<br />

Steckverbinder-Serie<br />

Frequency Range |<br />

Frequenzbereich<br />

Ordering Number<br />

RPC-N, 50 Ω DC-18.0 GHz 05 CK 200-150<br />

RPC-7 DC-18.0 GHz 07 CK 200-150<br />

RPC-3.50 DC-26.5 GHz 03 CK 200-150<br />

RPC-2.92 DC-40.0 GHz 02 CK 200-150<br />

Gauge Kits<br />

Connector Series |<br />

Steckverbinder-Serie<br />

RPC-N, 50 Ω<br />

RPC-N, 75 Ω<br />

RPC-TNC<br />

RPC-7<br />

RPC-3.50 / RPC-2.92<br />

RPC-2.40 / RPC-1.85<br />

RPC-1.00<br />

RPC-7-16<br />

Ordering Number<br />

05 GK 0KS-000<br />

P5 GK 0KS-000<br />

06 GK 0KS-000<br />

07 GK 0KS-000<br />

03 GK 0KS-000<br />

08 GK 0KS-000<br />

01 GK 0KS-000<br />

60 GK 0KS-000<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

13


<strong>Calibration</strong> Kits<br />

2<strong>Calibration</strong> Kits<br />

RPC-N, 50 Ω <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.20 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.5°<br />

≤ 3.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.15 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.2°<br />

≤ 2.5°<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 45 dB<br />

≥ 30 dB<br />

DC to ≤ 4<br />

>4 to ≤ 18<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.25 Ω<br />

DC<br />

Sliding loads 2 | Gleitlast<br />

(male and female)<br />

Precision air lines 3 |<br />

Präzisions-Luftleitungen<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 18<br />

Return Loss | Rückflussdämpfung ≥ 35 dB ≥ 2 to ≤ 18<br />

Return Loss | Rückflussdämpfung<br />

≥ 40 dB<br />

≥ 35 dB<br />

≥ 0.3 to ≤ 4<br />

> 4 to ≤ 18<br />

Characteristic Impedance | Wellenwiederstand<br />

50 Ω ± 0.25 Ω<br />

≥ 0.3 to ≤ 18<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 36 dB<br />

≥ 30 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

1. The specification for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

2. The specification for the sliding load termination include the quality of the air line<br />

portions within the sliding load combined with the effective stability of the sliding element.<br />

3. The characteristic impedance for the air lines is based on mechanical mesurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

the skin depth. Refer to the test report included in the kit for the exact dimensions of<br />

your precision air lines.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.07 mm<br />

DC to 18<br />

(±1.5° at 18 GHz)<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. Die Spezifikationen für die Gleitlast-Abschlüsse beziehen sich auf die Güte des<br />

Luftleitungs-Abschnitts in Verbindung mit der Reproduzierbarkeit des verschiebbaren<br />

Gleitlast-Elements.<br />

3. Der angegebene Wellenwiederstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

Skin-Effektes frequenzabhängigen Wellenwiederstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

14<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- N, 50 Right Ω or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-N, 50 Ω , Full Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

x05 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x05 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x05 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x05 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x05 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x05 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x05 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x05 S 150-G300 Sliding loads (male) |<br />

Gleitlast (Stecker)<br />

x05 K 150-G300 Sliding loads (female) |<br />

Gleitlast (Kuppler)<br />

x05 S 121-S20 S3 Adaptor (RPC-N, 50 Ω male - male) |<br />

Adapter (RPC-N, 50 Ω Stecker - Stecker)<br />

x05 K 121-K20 S3 Adaptor (RPC-N, 50 Ω female - female) |<br />

Adapter (RPC-N, 50 Ω Kuppler - Kuppler)<br />

x53 W 009-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x05 W 00K-000 Gauge (female) incl. Gauge Block |<br />

Messuhr (Kuppler) incl. Kalibrierblock<br />

x05 W 00S-000 Gauge (male) incl. Gauge Block |<br />

Messuhr (Stecker) incl. Kalibrierblock<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

20 mm wrench size / 1.1-Nm-torque |<br />

20-mm-Schlüssel / 1.1-Nm-Drehmoment<br />

to gauge female connectors |<br />

für Vermessung von Steckverbindern (Kuppler)<br />

to gauge male connectors |<br />

für Vermessung von Steckverbindern (Stecker)<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

15


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- N, 50 Right Ω or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-N, 50 Ω , Industrial Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

x05 CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x05 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x05 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x05 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x05 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x05 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x05 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x53 W 009-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

20 mm wrench size / 1.1-Nm-torque |<br />

20-mm-Schlüssel / 1.1-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

16<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- N, 50 Right Ω or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-N, 50 Ω , LRL Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

x05 CK 120-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

LRL Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x05 S 101-K026 26.4 mm Air line (male - female) |<br />

26.4-mm-Luftleitung (Stecker - Kuppler)<br />

x05 S 101-K033 33.3 mm Air line (male - female) |<br />

33.3-mm-Luftleitung (Stecker - Kuppler)<br />

x05 S 101-K061 61 mm Air line (male - female) |<br />

61-mm-Luftleitung (Stecker - Kuppler)<br />

x05 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x05 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x53 W 009-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L1 1<br />

L2 1<br />

L3 1<br />

Reflect standard |<br />

Reflexions-Norm<br />

Reflect standard |<br />

Reflexions-Norm<br />

20 mm wrench size / 1.1-Nm-torque |<br />

20-mm-Schlüssel / 1.1-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1 and L2<br />

0 3.6<br />

18<br />

f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1 and L3<br />

L1 and L2<br />

0 0.7 3.6<br />

18<br />

f in GHz<br />

LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of lines<br />

used during the calibration<br />

procedure. If two lines are used the third line can be used as verification standard.<br />

The graph besides shows two possibilities using LRL with lowband loads. Without<br />

lowband loads the lower band<br />

cannot be calibrated.<br />

LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-) bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von<br />

Möglichkeiten, vektorielle Netzwerk-Analysatoren zu kalibrieren. Bei Verwendung von<br />

zwei Leitungen wird die dritte Leitung als Verifizier-Standard genutzt. Nebenstehende<br />

Grafik zeigt zwei mögliche LRLKalibrierungen mit Niedrigband-Lastabschlüssen.<br />

Ohne diese Abschlüsse kann der untere Frequenzbereich nicht kalibriert werden.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

17


<strong>Calibration</strong> Kits<br />

RPC-N, 75 Ω <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.07 dB<br />

≤ 0.10 dB<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.0°<br />

≤ 1.6°<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.07 dB<br />

≤ 0.10 dB<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 0.8°<br />

≤ 1.2°<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 40 dB<br />

≥ 36 dB<br />

DC to ≤ 2<br />

>2 to ≤ 4<br />

Resistance | Gleichstrom-Widerstand<br />

75 Ω ± 0.75 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 4<br />

Precision air lines 3 |<br />

Präzisions-Luftleitungen<br />

Return Loss | Rückflussdämpfung<br />

≥ 42 dB<br />

≥ 40 dB<br />

≥ 0.1 to ≤ 2<br />

> 2 to ≤ 4<br />

Characteristic Impedance | Wellenwiederstand<br />

75 Ω ± 0.55 Ω<br />

≥ 0.1 to ≤ 4<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 38 dB<br />

≥ 34 dB<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

2. The characteristic impedance for the air lines is based on mechanical measurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

skin depth. Refer to the test report included in the kit for the exact dimensions of your<br />

precision air lines.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.07 mm<br />

DC to 4<br />

(±0.4° at 4 GHz)<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. Der angegebene Wellenwiderstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

"Skin-Effekts" frequenzabhängigen Wellenwiderstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

18<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- N, 75 Right Ω or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-N, 75 Ω , Full Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

xP5 CK 100-170 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

xP5 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

xP5 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

xP5 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

xP5 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

xP5 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

xP5 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

xP5 S 121-S20 S3 Adaptor (RPC-N, 75 Ω male - male) |<br />

Adapter (RPC-N, 75 Ω Stecker - Stecker)<br />

xP5 K 121-K20 S3 Adaptor (RPC-N, 75 Ω female - female) |<br />

Adapter (RPC-N, 75 Ω Kuppler - Kuppler)<br />

x53 W 009-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x05 W 00K-000 Gauge (female) incl. Gauge Block |<br />

Messuhr (Kuppler) incl. Kalibrierblock<br />

xP5 W 00S-000 Gauge (male) incl. Gauge Block |<br />

Messuhr (Stecker) incl. Kalibrierblock<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

20 mm wrench size / 1.1-Nm-torque |<br />

20-mm-Schlüssel / 1.1-Nm-Drehmoment<br />

to gauge female connectors |<br />

für Vermessung von Steckverbindern (Kuppler)<br />

to gauge male connectors |<br />

für Vermessung von Steckverbindern (Stecker)<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

19


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- N, 75 Right Ω or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-N, 75 Ω , Industrial Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

xP5 CK 10A-170 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

xP5 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

xP5 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

xP5 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

xP5 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

xP5 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

xP5 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x53 W 009-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

20 mm wrench size / 1.1-Nm-torque |<br />

20-mm-Schlüssel / 1.1-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

20<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- N, 75 Right Ω or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-N, 75 Ω , TRL Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

xP5 CK 120-170 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

TRL Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

xP5 S 101-K031 31.2 mm Air line (male - female) |<br />

31.2-mm-Luftleitung (Stecker - Kuppler)<br />

xP5 S 101-K150 150 mm Air line (male - female) |<br />

150-mm-Luftleitung (Stecker - Kuppler)<br />

xP5 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

xP5 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x53 W 009-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L2 1<br />

L3 1<br />

Reflect standard |<br />

Reflexions-Norm<br />

Reflect standard |<br />

Reflexions-Norm<br />

20 mm wrench size / 1.1-Nm-torque |<br />

20-mm-Schlüssel / 1.1-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1 = Thru and L2<br />

0 0.8<br />

4<br />

f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1 = Thru and L3<br />

L1 = Thru and L2<br />

0 0.16 0.8<br />

4<br />

f in GHz<br />

TRL/LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of<br />

lines used during the calibration procedure. If two lines are used the third line can be<br />

used as verification<br />

standard. The graph besides shows two possibilities using TRL with lowband loads.<br />

Without lowband loads the lower band cannot be calibrated. In this calibration kit line<br />

1 (L1) is the zero length thru connection.<br />

TRL/LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-) bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von Möglichkeiten, vektorielle Netzwerk-<br />

Analysatoren zu kalibrieren. Bei Verwendung von zwei Leitungen wird die dritte Leitung<br />

als Verifizier-Standard genutzt. Nebenstehende Grafik zeigt zwei mögliche TRL-<br />

Kalibrierungen mit Niedrigband-Lastabschlüssen. Ohne diese Abschlüsse kann der<br />

untere Frequenzbereich nicht kalibriert werden. In diesem Kalibrier-Kit ist die Leitung<br />

1 (L1) eine Thru-Leitung mit Länge Null.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

21


<strong>Calibration</strong> Kits<br />

RPC-TNC <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.50 dB<br />

≤ 1.00 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 3.5°<br />

≤ 8.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.50 dB<br />

≤ 1.00 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.0°<br />

≤ 7.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 35 dB<br />

≥ 25 dB<br />

DC to ≤ 4<br />

>4 to ≤ 18<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.50 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

Adaptors | Adapter Return Loss | Rückflussdämpfung ≥ 30 dB<br />

≥ 20 dB<br />

Adaptors | Adapter<br />

Return Loss | Rückflussdämpfung<br />

(RPC-N/RPC-TNC)<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

≥ 30 dB<br />

≥ 20 dB<br />

DC to 18<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

22<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrier- Masterpage-Wechsel: Kits RPC- TNC Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-TNC, Full Version<br />

<strong>Calibration</strong> Kit RPC-TNC<br />

xOrdering Number<br />

Remarks<br />

x06 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x06 S 150-C10 S3 Termination (male) |<br />

Abschlusswiderstand (Stecker)<br />

x06 K 150-C10 S3 Termination (female) |<br />

Abschlusswiderstand (Kuppler)<br />

x06 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x06 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x06 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x06 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x06 S 121-S20 S3 Adaptor (RPC-TNC male - male) |<br />

Adapter (RPC-TNC Stecker - Stecker)<br />

x06 K 121-K20 S3 Adaptor (RPC-TNC female - female) |<br />

Adapter (RPC-TNC Kuppler - Kuppler)<br />

x05 S 106-S20 S3 Adaptor (RPC-N, 50 Ω male - RPC-TNC male) |<br />

Adapter (RPC-N, 50 Ω Stecker - RPC-TNC Stecker)<br />

x05 K 106-K20 S3 Adaptor (RPC-N, 50 Ω female - RPC-TNC female) |<br />

Adapter (RPC-N, 50 Ω Kuppler - RPC-TNC Kuppler)<br />

x06 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

15 mm wrench size / 55 Ncm torque |<br />

15-mm-Schlüssel / 55 Ncm Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

23


<strong>Calibration</strong> Kits<br />

Kalibrier- Masterpage-Wechsel: Kits RPC- TNC Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-TNC, Industrial Version<br />

<strong>Calibration</strong> Kit RPC-TNC<br />

xOrdering Number<br />

Remarks<br />

x06 CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x06 S 150-C10 S3 Termination (male) |<br />

Abschlusswiderstand (Stecker)<br />

x06 K 150-C10 S3 Termination (female) |<br />

Abschlusswiderstand (Kuppler)<br />

x06 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x06 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x06 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x06 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x06 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

15 mm wrench size / 55 Ncm torque |<br />

15-mm-Schlüssel / 55 Ncm Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

24<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

25


<strong>Calibration</strong> Kits<br />

RPC-7 <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.15 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.2°<br />

≤ 2.5°<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.07 dB<br />

≤ 0.12 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 0.7°<br />

≤ 1.5°<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 45 dB<br />

≥ 32 dB<br />

DC to ≤ 4<br />

>4 to ≤ 18<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.50 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 18<br />

Sliding loads 2 | Gleitlast Return Loss | Rückflussdämpfung ≥ 40 dB ≥ 2 to ≤ 18<br />

Precision air lines 3 |<br />

Präzisions-Luftleitungen<br />

Return Loss | Rückflussdämpfung<br />

≥ 45 dB<br />

≥ 40 dB<br />

≥ 0.3 to ≤ 4<br />

> 4 to ≤ 18<br />

Characteristic Impedance | Wellenwiederstand<br />

1. The specification for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

2. The specification for the sliding load termination include the quality of the air line<br />

portions within the sliding load combined with the effective stability of the sliding element.<br />

3. The characteristic impedance for the air lines is based on mechanical mesurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

the skin depth. Refer to the test report included in the kit for the exact dimensions of<br />

your precision air lines.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

50 Ω ± 0.15 Ω<br />

≥ 0.3 to ≤ 18<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. Die Spezifikationen für die Gleitlast-Abschlüsse beziehen sich auf die Güte des<br />

Luftleitungs-Abschnitts in Verbindung mit der Reproduzierbarkeit des verschiebbaren<br />

Gleitlast-Elements.<br />

3. Der angegebene Wellenwiederstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

Skin-Effektes frequenzabhängigen Wellenwiederstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

26<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 7 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-7, Full Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

x07 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x07 P 12L-000 S3 Open circuit |<br />

Leerlauf<br />

x07 P 12S-000 S3 Open circuit |<br />

Leerlauf<br />

x07 P 150-C10 S3 Broadband load |<br />

Breitband-Last<br />

x07 P 150-G300 Sliding load |<br />

Gleitlast<br />

x07 W 031-000 Collet extractor |<br />

Demontage-Werkzeug<br />

x07 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x07 W 001-000 Gauge incl. Gauge Block |<br />

Messuhr inkl. Kalibrierblock<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

to remove center conductor collets |<br />

zum Entfernen des Innenleiter-Kontaktes<br />

19 mm wrench size / 1.36 Nm torque |<br />

19-mm-Schlüssel / 1.36-Nm-Drehmoment<br />

to gauge connectors |<br />

für Vermessung von Steckverbindern<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

27


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 7 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-7, Industrial Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

x07 CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x07 P 12L-000 S3 Open circuit |<br />

Leerlauf<br />

x07 P 12S-000 S3 Short circuit |<br />

Kurzschluss<br />

x07 P 150-C10 S3 Broadband load |<br />

Breitband-Last<br />

x07 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

19 mm wrench size / 1.36 Nm torque |<br />

19-mm-Schlüssel / 1.36-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

28<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 7 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-7, LRL Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

x07 CK 120-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

LRL Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x07 P 101-P034 34 mm Air line |<br />

34-mm-Luftleitung<br />

x07 P 101-P041 41 mm Air line |<br />

41-mm-Luftleitung<br />

x07 P 101-P068 68 mm Air line |<br />

68-mm-Luftleitung<br />

x07 P 12S-000 S3 Short circuit |<br />

Kurzschluss<br />

x07 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L1 1<br />

L2 1<br />

L3 1<br />

Reflect standard |<br />

Reflexions-Norm<br />

19 mm wrench size / 1.36 Nm torque |<br />

19-mm-Schlüssel / 1.36-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1 and L2<br />

0 3.6<br />

18<br />

f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1 and L3<br />

L1 and L2<br />

0 0.7 3.6<br />

18<br />

f in GHz<br />

LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of lines<br />

used during the calibration<br />

procedure. If two lines are used the third line can be used as verification standard.<br />

The graph besides shows two possibilities using LRL with lowband loads. Without<br />

lowband loads the lower band<br />

cannot be calibrated.<br />

LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-)bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von<br />

Möglichkeiten, vektorielle Netzwerk-Analysatoren zu kalibrieren. Bei Verwendung von<br />

zwei Leitungen wird die dritte Leitung als Verifizier-Standard genutzt. Nebenstehende<br />

Grafik zeigt zwei mögliche LRLKalibrierungen mit Niedrigband-Lastabschlüssen.<br />

Ohne diese Abschlüsse kann der untere Frequenzbereich nicht kalibriert werden.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

29


<strong>Calibration</strong> Kits<br />

RPC-SP, <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.15 dB<br />

≤ 0.20 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 22<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 2.5°<br />

≤ 5.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 22<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.15 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 22<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 2.0°<br />

≤ 4.5°<br />

DC to ≤ 4<br />

> 4 to ≤ 22<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 34 dB<br />

≥ 26 dB<br />

≥ 23 dB<br />

DC to ≤ 4<br />

>4 to ≤ 18<br />

>18 to ≤ 22<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.50 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 22<br />

Precision air lines 2 |<br />

Präzisions-Luftleitungen<br />

Return Loss | Rückflussdämpfung<br />

≥ 36 dB<br />

≥ 32 dB<br />

≥ 0.2 to ≤ 4<br />

> 4 to ≤ 22<br />

Adaptors | Adapter<br />

(RPC-3.50/RPC-SP)<br />

Adaptors | Adapter<br />

(RPC-7/RPC-SP)<br />

Characteristic Impedance | Wellenwiederstand<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Adaptors | Adapter<br />

Return Loss | Rückflussdämpfung<br />

(RPC-3.50/RPC-7)<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

2. The characteristic impedance for the air lines is based on mechanical measurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

skin depth. Refer to the test report included in the kit for the exact dimensions of your<br />

precision air lines.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

50 Ω ± 0.70 Ω<br />

≥ 34 dB<br />

≥ 26 dB<br />

≥ 34 dB<br />

≥ 26 dB<br />

≥ 36 dB<br />

≥ 28 dB<br />

≥ 0.2 to ≤ 22<br />

DC to ≤ 4<br />

> 4 to ≤ 22<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. Der angegebene Wellenwiderstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

"Skin-Effekts" frequenzabhängigen Wellenwiderstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

30<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrier- Masterpage-Wechsel: Kits RPC- SPRight or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-SP, Full Version<br />

<strong>Calibration</strong> Kit RPC-SP<br />

xOrdering Number<br />

Remarks<br />

x10 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x10 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x10 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x10 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x10 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x10 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x10 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x07 P 110-S20 S3 Adaptor (RPC-7 - RPC-SP male) |<br />

Adapter (RPC-7 - RPC-SP Stecker)<br />

x07 P 110-K20 S3 Adaptor (RPC-7 - RPC-SP female) |<br />

Adapter (RPC-7 - RPC-SP Kuppler)<br />

x03 K 110-S21 S3 Adaptor (RPC-3.50 female - RPC-SP male) |<br />

Adapter (RPC-3.50 Kuppler - RPC-SP Stecker)<br />

x03 K 110-K21 S3 Adaptor (RPC-3.50 female - RPC-SP female) |<br />

Adapter (RPC-3.50 Kuppler - RPC-SP Kuppler)<br />

x03 S 110-S21 S3 Adaptor (RPC-3.50 male - RPC-SP male) |<br />

Adapter (RPC-3.50 Stecker - RPC-SP Stecker)<br />

x03 S 110-K21 S3 Adaptor (RPC-3.50 male - RPC-SP female) |<br />

Adapter (RPC-3.50 Stecker - RPC-SP Kuppler)<br />

x03 S 107-P20 S3 Adaptor (RPC-3.50 male - RPC-7) |<br />

Adapter (RPC-3.50 Stecker - RPC-7)<br />

x03 K 107-P20 S3 Adaptor (RPC-3.50 female - RPC-7) |<br />

Adapter (RPC-3.50 Kuppler - RPC-7)<br />

x07 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x10 Z 001-S00 S Coupling Nut with male thread |<br />

Überwurfmutter mit Steckergewinde<br />

x10 Z 001-K00 S Coupling Nut with female thread |<br />

Überwurfmutter mit Kupplergewinde<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

19 mm wrench size / 1.36 Nm torque |<br />

19-mm-Schlüssel / 1.36 Nm Drehmoment<br />

11/16-24 UNEF-2A thread |<br />

11/16-24 UNEF-2A Gewinde<br />

11/16-24 UNEF-2B thread |<br />

11/16-24 UNEF-2B Gewinde<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

31


<strong>Calibration</strong> Kits<br />

Kalibrier- Masterpage-Wechsel: Kits RPC- SPRight or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-SP, TRL Version<br />

<strong>Calibration</strong> Kit RPC-SP<br />

xOrdering Number<br />

Remarks<br />

x10 CK 120-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

TRL Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x10 S 101-K005 5.6 mm Air line (male - female) |<br />

5.6-mm-Luftleitung (Stecker - Kuppler)<br />

x10 S 101-K027 27.7 mm Air line (male - female) |<br />

27.7-mm-Luftleitung (Stecker - Kuppler)<br />

x10 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x10 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x10 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x10 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x03 K 110-S21 S3 Adaptor (RPC-3.50 female - RPC-SP male) |<br />

Adapter (RPC-3.50 Kuppler - RPC-SP Stecker)<br />

x03 K 110-K21 S3 Adaptor (RPC-3.50 female - RPC-SP female) |<br />

Adapter (RPC-3.50 Kuppler - RPC-SP Kuppler)<br />

x03 S 110-S21 S3 Adaptor (RPC-3.50 male - RPC-SP male) |<br />

Adapter (RPC-3.50 Stecker - RPC-SP Stecker)<br />

x03 S 110-K21 S3 Adaptor (RPC-3.50 male - RPC-SP female) |<br />

Adapter (RPC-3.50 Stecker - RPC-SP Kuppler)<br />

x07 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x10 Z 001-S00 S Coupling Nut with male thread |<br />

Überwurfmutter mit Steckergewinde<br />

x10 Z 001-K00 S Coupling Nut with female thread |<br />

Überwurfmutter mit Kupplergewinde<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L2 1<br />

L3 1<br />

may be used as lowband load |<br />

auch als Niedrigfrequenz-Lastabschluss einsetzbar<br />

may be used as lowband load |<br />

auch als Niedrigfrequenz-Lastabschluss einsetzbar<br />

19 mm wrench size / 1.36 Nm torque |<br />

19-mm-Schlüssel / 1.36 Nm Drehmoment<br />

11/16-24 UNEF-2A thread |<br />

11/16-24 UNEF-2A Gewinde<br />

11/16-24 UNEF-2B thread |<br />

11/16-24 UNEF-2B Gewinde<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C, R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1 = Thru and L2<br />

0 4.5<br />

22<br />

f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1 = Thru and L3<br />

L1 = Thru and L2<br />

0 0.9 4.5<br />

22<br />

f in GHz<br />

32<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

TRL/LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of<br />

lines used during the calibration procedure. If two lines are used the third line can be<br />

used as verification<br />

standard. The graph besides shows two possibilities using TRL with lowband loads.<br />

Without lowband loads the lower band cannot be calibrated. In this calibration kit line<br />

1 (L1) is the zero length thru connection.<br />

TRL/LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-) bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von Möglichkeiten, vektorielle Netzwerk-<br />

Analysatoren zu kalibrieren. Bei Verwendung von zwei Leitungen wird die dritte Leitung<br />

als Verifizier-Standard genutzt. Nebenstehende Grafik zeigt zwei mögliche TRL-<br />

Kalibrierungen mit Niedrigband-Lastabschlüssen. Ohne diese Abschlüsse kann der<br />

untere Frequenzbereich nicht kalibriert werden.<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

33


<strong>Calibration</strong> Kits<br />

RPC-3.50, <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.20 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 26.5<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.0°<br />

≤ 2.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 26.5<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.15 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 26.5<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.2°<br />

≤ 2.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 26.5<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 40 dB<br />

≥ 30 dB<br />

DC to ≤ 4<br />

>4 to ≤ 26.5<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.25 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 26.5<br />

Sliding loads 2 | Gleitlast<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 26.4 dB<br />

≥ 32 dB<br />

≥ 2 to ≤ 4<br />

> 4 to ≤ 26.5<br />

Precision air lines 3 |<br />

Präzisions-Luftleitungen<br />

Return Loss | Rückflussdämpfung<br />

≥ 40 dB<br />

≥ 35 dB<br />

≥ 0.3 to ≤ 4<br />

> 4 to ≤ 26.5<br />

Characteristic Impedance | Wellenwiederstand<br />

50 Ω ± 0.35 Ω<br />

≥ 0.3 to ≤ 26.5<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 34 dB<br />

≥ 30 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 26.5<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

1. The specification for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

2. The specification for the sliding load termination include the quality of the air line<br />

portions within the sliding load combined with the effective stability of the sliding element.<br />

3. The characteristic impedance for the air lines is based on mechanical mesurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

the skin depth. Refer to the test report included in the kit for the exact dimensions of<br />

your precision air lines.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Characteristics.<br />

Individual values of connectors may deviate depending upon application,<br />

design, type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.12 mm<br />

DC to 26.5<br />

(±3.8° at 26.5 GHz)<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. Die Spezifikationen für die Gleitlast-Abschlüsse beziehen sich auf die Güte des<br />

Luftleitungs-Abschnitts in Verbindung mit der Reproduzierbarkeit des verschiebbaren<br />

Gleitlast-Elements.<br />

3. Der angegebene Wellenwiederstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

Skin-Effektes frequenzabhängigen Wellenwiederstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

34<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 3.50 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-3.50, Full Version<br />

<strong>Calibration</strong> Kit RPC-3.50<br />

xOrdering Number<br />

Remarks<br />

x03 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x03 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x03 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x03 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x03 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x03 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x03 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x03 S 150-G300 Sliding load (male) |<br />

Gleitlast (Stecker)<br />

x03 K 150-G300 Sliding load (female) |<br />

Gleitlast (Kuppler)<br />

x03 S 121-S20 S3 Adaptor (RPC-3.50 male - male) |<br />

Adapter (RPC-3.50 Stecker - Stecker)<br />

x03 K 121-K20 S3 Adaptor (RPC-3.50 female - female) |<br />

Adapter (RPC-3.50 Kuppler - Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x03 W 00K-000 Gauge (female) incl. Gauge Block |<br />

Messuhr (Kuppler) incl. Kalibrierblock<br />

x03 W 00S-000 Gauge (male) incl. Gauge Block |<br />

Messuhr (Stecker) incl. Kalibrierblock<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

to gauge female connectors |<br />

für Vermessung von Steckverbindern (Kuppler)<br />

to gauge male connectors |<br />

für Vermessung von Steckverbindern (Stecker)<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

35


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 3.50 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-3.50, Industrial Version<br />

<strong>Calibration</strong> Kit RPC-3.50<br />

xOrdering Number<br />

Remarks<br />

x03 CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x03 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x03 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x03 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x03 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x03 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x03 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

36<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 3.50 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-3.50, LRL Version<br />

<strong>Calibration</strong> Kit RPC-3.50<br />

xOrdering Number<br />

Remarks<br />

x03 CK 120-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

LRL Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x03 S 101-K015 15 mm Air line (male - female) |<br />

15-mm-Luftleitung (Stecker - Kuppler)<br />

x03 S 101-K020 20 mm Air line (male - female) |<br />

20-mm-Luftleitung (Stecker - Kuppler)<br />

x03 S 101-K038 38.5 mm Air line (male - female) |<br />

38.5-mm-Luftleitung (Stecker - Kuppler)<br />

x03 S 12S-001 D3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x03 K 12S-001 D3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L1 1<br />

L2 1<br />

L3 1<br />

Reflect standard |<br />

Reflexions-Norm<br />

Reflect standard |<br />

Reflexions-Norm<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Disk verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C, R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1 and L2<br />

0 5<br />

26.5<br />

f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1 and L3<br />

L1 and L2<br />

0 1<br />

5<br />

26.5<br />

f in GHz<br />

LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of lines<br />

used during the calibration<br />

procedure. If two lines are used the third line can be used as verification standard.<br />

The graph besides shows two possibilities using LRL with lowband loads. Without<br />

lowband loads the lower band<br />

cannot be calibrated.<br />

LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-) bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von<br />

Möglichkeiten, vektorielle Netzwerk-Analysatoren zu kalibrieren. Bei Verwendung von<br />

zwei Leitungen wird die dritte Leitung als Verifizier-Standard genutzt. Nebenstehende<br />

Grafik zeigt zwei mögliche LRLKalibrierungen mit Niedrigband-Lastabschlüssen.<br />

Ohne diese Abschlüsse kann der untere Frequenzbereich nicht kalibriert werden.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

37


<strong>Calibration</strong> Kits<br />

RPC-2.92, <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.20 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 40<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.0°<br />

≤ 2.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 40<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.20 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 40<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.0°<br />

≤ 2.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 40<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 42 dB<br />

≥ 30 dB<br />

DC to ≤ 4<br />

>4 to ≤ 40<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.25 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 40<br />

Sliding loads 2 | Gleitlast<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 28 dB<br />

≥ 32 dB<br />

≥ 4 to ≤ 8<br />

≥ 8 to ≤ 40<br />

Precision air lines 3 |<br />

Präzisions-Luftleitungen<br />

Return Loss | Rückflussdämpfung<br />

≥ 38 dB<br />

≥ 30 dB<br />

≥ 0.3 to ≤ 4<br />

> 4 to ≤ 40<br />

Characteristic Impedance | Wellenwiederstand<br />

50 Ω ± 0.40 Ω<br />

≥ 0.3 to ≤ 40<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 32 dB<br />

≥ 25 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 40<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

1. The specification for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

2. The specification for the sliding load termination include the quality of the air line<br />

portions within the sliding load combined with the effective stability of the sliding element.<br />

3. The characteristic impedance for the air lines is based on mechanical mesurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

the skin depth. Refer to the test report included in the kit for the exact dimensions of<br />

your precision air lines.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Characteristics.<br />

Individual values of connectors may deviate depending upon application,<br />

design, type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.12 mm<br />

DC to 40<br />

(±5.8° at 40 GHz)<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. Die Spezifikationen für die Gleitlast-Abschlüsse beziehen sich auf die Güte des<br />

Luftleitungs-Abschnitts in Verbindung mit der Reproduzierbarkeit des verschiebbaren<br />

Gleitlast-Elements.<br />

3. Der angegebene Wellenwiederstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

Skin-Effektes frequenzabhängigen Wellenwiederstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

38<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 2.92 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-2.92, Full Version<br />

<strong>Calibration</strong> Kit RPC-2.92<br />

xOrdering Number<br />

Remarks<br />

x02 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x02 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x02 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x02 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x02 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x02 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x02 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x02 S 150-G300 Sliding loads (male) |<br />

Gleitlast (Stecker)<br />

x02 K 150-G300 Sliding loads (female) |<br />

Gleitlast (Kuppler)<br />

x02 S 121-S20 S3 Adaptor (RPC-2.92 male - male) |<br />

Adapter (RPC-2.92 Stecker - Stecker)<br />

x02 K 121-K20 S3 Adaptor (RPC-2.92 female - female) |<br />

Adapter (PRC-2.92 Kuppler - Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x03 W 00K-000 Gauge (female) incl. Gauge Block |<br />

Messuhr (Kuppler) incl. Kalibrierblock<br />

x03 W 00S-000 Gauge (male) incl. Gauge Block |<br />

Messuhr (Stecker) incl. Kalibrierblock<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

to gauge female connectors |<br />

für Vermessung von Steckverbindern (Kuppler)<br />

to gauge male connectors |<br />

für Vermessung von Steckverbindern (Stecker)<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

39


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 2.92 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-2.92, Industrial Version<br />

<strong>Calibration</strong> Kit RPC-2.92<br />

xOrdering Number<br />

Remarks<br />

x02 CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x02 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x02 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x02 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x02 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x02 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x02 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

40<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 2.92 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-2.92, LRL Version<br />

<strong>Calibration</strong> Kit RPC-2.92<br />

xOrdering Number<br />

Remarks<br />

x02 CK 120-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

LRL Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x02 S 101-K015 15 mm Air line (male - female) |<br />

15-mm-Luftleitung (Stecker - Kuppler)<br />

x02 S 101-K018 18.3 mm Air line (male - female) |<br />

18.3-mm-Luftleitung (Stecker - Kuppler)<br />

x02 S 101-K040 40 mm Air line (male - female) |<br />

40-mm-Luftleitung (Stecker - Kuppler)<br />

x02 S 12S-001 D3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x02 K 12S-001 D3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L1 1<br />

L2 1<br />

L3 1<br />

Reflect standard |<br />

Reflexions-Norm<br />

Reflect standard |<br />

Reflexions-Norm<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C, R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1 and L2<br />

0 5<br />

40<br />

f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1 and L3<br />

L1 and L2<br />

0 1<br />

5<br />

40<br />

f in GHz<br />

LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of lines<br />

used during the calibration<br />

procedure. If two lines are used the third line can be used as verification standard.<br />

The graph besides shows two possibilities using LRL with lowband loads. Without<br />

lowband loads the lower band<br />

cannot be calibrated.<br />

LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-) bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von Möglichkeiten, vektorielle Netzwerk-Analysatoren zu<br />

kalibrieren. Bei Verwendung von zwei Leitungen wird die dritte Leitung als Verifizier-<br />

Standard genutzt. Nebenstehende Grafik zeigt zwei mögliche LRLKalibrierungen mit<br />

Niedrigband-Lastabschlüssen. Ohne diese Abschlüsse kann der untere Frequenzbereich<br />

nicht kalibriert werden.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

41


<strong>Calibration</strong> Kits<br />

RPC-2.40, <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.15 dB<br />

≤ 0.30 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 50<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 2.0°<br />

≤ 6.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 50<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.15 dB<br />

≤ 0.25 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 50<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.5°<br />

≤ 4.5°<br />

DC to ≤ 4<br />

> 4 to ≤ 50<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 36 dB<br />

≥ 30 dB<br />

≥ 26 dB<br />

≥ 22 dB<br />

DC to ≤ 4<br />

>4 to ≤ 20<br />

>20 to ≤ 26.5<br />

>26.5 to ≤ 50<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.25 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 50<br />

Precision air lines 2 |<br />

Präzisions-Luftleitungen<br />

Return Loss | Rückflussdämpfung<br />

≥ 36 dB<br />

≥ 26 dB<br />

≥ 0.4 to ≤ 4<br />

> 4 to ≤ 50<br />

Characteristic Impedance | Wellenwiederstand<br />

50 Ω ± 0.95 Ω<br />

≥ 0.4 to ≤ 50<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 30 dB<br />

≥ 17 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 50<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

2. The characteristic impedance for the air lines is based on mechanical measurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

skin depth. Refer to the test report included in the kit for the exact dimensions of your<br />

precision air lines.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Characteristics.<br />

Individual values of connectors may deviate depending upon application,<br />

design, type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.15 mm<br />

DC to 50<br />

(±9° at 50 GHz)<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. Der angegebene Wellenwiderstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

"Skin-Effekts" frequenzabhängigen Wellenwiderstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

42<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 2.40 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-2.40, Full Version<br />

<strong>Calibration</strong> Kit RPC-2.40<br />

xOrdering Number<br />

Remarks<br />

x09 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x09 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x09 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x09 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x09 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x09 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x09 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x09 S 121-S20 S3 Adaptor (RPC-2.40 male - male) |<br />

Adapter (RPC-2.40 Stecker - Stecker)<br />

x09 K 121-K20 S3 Adaptor (RPC-2.40 female - female) |<br />

Adapter (RPC-2.40 Kuppler - Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x08 W 00K-000 Gauge (female) incl. Gauge Block |<br />

Messuhr (Kuppler) incl. Kalibrierblock<br />

x08 W 00S-000 Gauge (male) incl. Gauge Block |<br />

Messuhr (Stecker) incl. Kalibrierblock<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

to gauge female connectors |<br />

für Vermessung von Steckverbindern (Kuppler)<br />

to gauge male connectors |<br />

für Vermessung von Steckverbindern (Stecker)<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

43


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 2.40 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-2.40, Industrial Version<br />

<strong>Calibration</strong> Kit RPC-2.40<br />

xOrdering Number<br />

Remarks<br />

x09 CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x09 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x09 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x09 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x09 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x09 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x09 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

44<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 2.40 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-2.40, LRL Version<br />

<strong>Calibration</strong> Kit RPC-2.40<br />

xOrdering Number<br />

Remarks<br />

x09 CK 120-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

LRL Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x09 S 101-K013 13 mm Air line (male - female) |<br />

13-mm-Luftleitung (Stecker - Kuppler)<br />

x09 S 101-K015 15.5 mm Air line (male - female) |<br />

15.5-mm-Luftleitung (Stecker - Kuppler)<br />

x09 S 101-K025 25.5 mm Air line (male - female) |<br />

25.5-mm-Luftleitung (Stecker - Kuppler)<br />

x09 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x09 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L1 1<br />

L2 1<br />

L3 1<br />

Reflect standard |<br />

Reflexions-Norm<br />

Reflect standard |<br />

Reflexions-Norm<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C, R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1 and L2<br />

0 10<br />

50<br />

f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1 and L3<br />

L1 and L2<br />

0 2<br />

10<br />

50<br />

f in GHz<br />

LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of lines<br />

used during the calibration<br />

procedure. If two lines are used the third line can be used as verification standard.<br />

The graph besides shows two possibilities using LRL with lowband loads. Without<br />

lowband loads the lower band<br />

cannot be calibrated.<br />

LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-) bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von<br />

Möglichkeiten, vektorielle Netzwerk-Analysatoren zu kalibrieren. Bei Verwendung von<br />

zwei Leitungen wird die dritte Leitung als Verifizier-Standard genutzt. Nebenstehende<br />

Grafik zeigt zwei mögliche LRLKalibrierungen mit Niedrigband-Lastabschlüssen.<br />

Ohne diese Abschlüsse kann der untere Frequenzbereich nicht kalibriert werden.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

45


<strong>Calibration</strong> Kits<br />

RPC-1.85, <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.15 dB<br />

≤ 0.40 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 65<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 2.5°<br />

≤ 9.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 65<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.15 dB<br />

≤ 0.30 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 65<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 2.0°<br />

≤ 6.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 65<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 34 dB<br />

≥ 25 dB<br />

≥ 22 dB<br />

≥ 20 dB<br />

DC to ≤ 4<br />

>4 to ≤ 26.5<br />

>26.5 to ≤ 50<br />

>50 to ≤ 65<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.25 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 65<br />

Precision air lines 2 |<br />

Präzisions-Luftleitungen<br />

Return Loss | Rückflussdämpfung<br />

≥ 34 dB<br />

≥ 24 dB<br />

≥ 0.5 to ≤ 4<br />

> 4 to ≤ 65<br />

Characteristic Impedance | Wellenwiederstand<br />

50 Ω ± 1.00 Ω<br />

≥ 0.5 to ≤ 65<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 28 dB<br />

≥ 17 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 65<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

2. The characteristic impedance for the air lines is based on mechanical measurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

skin depth. Refer to the test report included in the kit for the exact dimensions of your<br />

precision air lines.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Characteristics.<br />

Individual values of connectors may deviate depending upon application,<br />

design, type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.15 mm<br />

DC to 65<br />

(±11.7° at 65 GHz)<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. Der angegebene Wellenwiderstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

"Skin-Effekts" frequenzabhängigen Wellenwiderstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

46<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 1.85 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-1.85, Full Version<br />

<strong>Calibration</strong> Kit RPC-1.85<br />

xOrdering Number<br />

Remarks<br />

x08 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x08 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x08 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x08 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x08 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x08 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x08 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x08 S 121-S20 S3 Adaptor (RPC-1.85 male - male) |<br />

Adapter (RPC-1.85 Stecker - Stecker)<br />

x08 K 121-K20 S3 Adaptor (RPC-1.85 female - female) |<br />

Adapter (RPC-1.85 Kuppler - Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x08 W 00K-000 Gauge (female) incl. Gauge Block |<br />

Messuhr (Kuppler) incl. Kalibrierblock<br />

x08 W 00S-000 Gauge (male) incl. Gauge Block |<br />

Messuhr (Stecker) incl. Kalibrierblock<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

to gauge female connectors |<br />

für Vermessung von Steckverbindern (Kuppler)<br />

to gauge male connectors |<br />

für Vermessung von Steckverbindern (Stecker)<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

47


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 1.85 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-1.85, Industrial Version<br />

<strong>Calibration</strong> Kit RPC-1.85<br />

xOrdering Number<br />

Remarks<br />

x08 CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x08 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x08 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x08 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x08 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x08 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x08 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

48<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 1.85 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-1.85, LRL Version<br />

<strong>Calibration</strong> Kit RPC-1.85<br />

xOrdering Number<br />

Remarks<br />

x08 CK 120-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

LRL Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x08 S 101-K013 13 mm Air line (male - female) |<br />

13-mm-Luftleitung (Stecker - Kuppler)<br />

x08 S 101-K014 14.9 mm Air line (male - female) |<br />

14.9-mm-Luftleitung (Stecker - Kuppler)<br />

x08 S 101-K022 22.6 mm Air line (male - female) |<br />

22.6-mm-Luftleitung (Stecker - Kuppler)<br />

x08 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x08 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L1 1<br />

L2 1<br />

L3 1<br />

Reflect standard |<br />

Reflexions-Norm<br />

Reflect standard |<br />

Reflexions-Norm<br />

8 mm wrench size / 0.9-Nm-torque |<br />

8-mm-Schlüssel / 0.9-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C,<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1 and L2<br />

0 13<br />

65<br />

f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1 and L3<br />

L1 and L2<br />

0 2.6 13<br />

65<br />

f in GHz<br />

LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of lines<br />

used during the calibration<br />

procedure. If two lines are used the third line can be used as verification standard.<br />

The graph besides shows two possibilities using LRL with lowband loads. Without<br />

lowband loads the lower band<br />

cannot be calibrated.<br />

LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-) bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von<br />

Möglichkeiten, vektorielle Netzwerk-Analysatoren zu kalibrieren. Bei Verwendung von<br />

zwei Leitungen wird die dritte Leitung als Verifizier-Standard genutzt. Nebenstehende<br />

Grafik zeigt zwei mögliche LRLKalibrierungen mit Niedrigband-Lastabschlüssen.<br />

Ohne diese Abschlüsse kann der untere Frequenzbereich nicht kalibriert werden.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

49


<strong>Calibration</strong> Kits<br />

RPC-1.00, <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.20 dB<br />

≤ 0.50 dB<br />

≤ 0.75 dB<br />

≤ 1.00 dB<br />

DC to ≤ 20<br />

> 20 to ≤ 50<br />

> 50 to ≤ 75<br />

> 75 to ≤ 110<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 4.0°<br />

≤ 6.0°<br />

≤ 8.0°<br />

≤ 11.0°<br />

DC to ≤ 20<br />

> 20 to ≤ 50<br />

> 50 to ≤ 75<br />

> 75 to ≤ 110<br />

Lowband loads | Niedrigfrequenz-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 36 dB<br />

≥ 30 dB<br />

≥ 28 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

> 18 to ≤ 22<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.60 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 22<br />

Precision air lines 2 |<br />

Präzisions-Luftleitungen<br />

Return Loss |<br />

Rückflussdämpfung<br />

≥ 24 dB<br />

≥ 20 dB<br />

≥ 18 dB<br />

≥ 14 dB<br />

DC to ≤ 20<br />

> 20 to ≤ 50<br />

> 50 to ≤ 75<br />

> 75 to ≤ 110<br />

Characteristic Impedance | Wellenwiederstand<br />

50 Ω ± 1.15 Ω<br />

≥ 0.8 to ≤ 110<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 20 dB<br />

≥ 17 dB<br />

≥ 15 dB<br />

≥ 12 dB<br />

DC to ≤ 20<br />

> 20 to ≤ 50<br />

> 50 to ≤ 75<br />

> 75 to ≤ 110<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

2. The characteristic impedance for the air lines is based on mechanical measurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

skin depth. Refer to the test report included in the kit for the exact dimensions of your<br />

precision air lines.<br />

3. Operating Temperature: +20°C to 26°C<br />

Storage Temperature: -40°C to +85°C<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Characteristics.<br />

Individual values of connectors may deviate depending upon application,<br />

design, type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.12 mm<br />

DC to 110<br />

(±15.8° at 110 GHz)<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. Der angegebene Wellenwiderstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

"Skin-Effekts" frequenzabhängigen Wellenwiderstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

3. Betriebstemperatur: +20°C bis 26°C<br />

Lagertemperatur: -40°C bis +85°C<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

50<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: RPC- 1.00 Right or Left (1col)<br />

<strong>Calibration</strong> Kit RPC-1.00, LRL Version<br />

<strong>Calibration</strong> Kit RPC-1.00<br />

xOrdering Number<br />

Remarks<br />

x01 CK 120-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

LRL Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x01 S 101-K011 11 mm Air line (male - female) |<br />

11-mm-Luftleitung (Stecker - Kuppler)<br />

x01 S 101-K012 12.14 mm Air line (male - female) |<br />

12.14-mm-Luftleitung (Stecker - Kuppler)<br />

x01 S 101-K016 16.68 mm Air line (male - female) |<br />

16.68-mm-Luftleitung (Stecker - Kuppler)<br />

x01 S 12S-000 D3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x01 K 12S-000 D3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x01 S 150-C10 D3 Lowband load (male) |<br />

Niedrigfrequenz-Last (Stecker)<br />

x01 K 150-C10 D3 Lowband load (female) |<br />

Niedrigfrequenz-Last (Kuppler)<br />

x01 S 101-K01 D3 Adaptor (RPC-1.00 male - female) |<br />

Adapter (RPC-1.00 Stecker - Kuppler)<br />

x01 S 101-K02 D3 Adaptor (RPC-1.00 male - female) |<br />

Adapter (RPC-1.00 Stecker - Kuppler)<br />

x01 S 101-S20 D3 Adaptor (RPC-1.00 male - male) |<br />

Adapter (RPC-1.00 Stecker - Stecker)<br />

x01 K 101-K20 D3 Adaptor (RPC-1.00 female - female) |<br />

Adapter (RPC-1.00 Kuppler - Kuppler)<br />

x01 S 101-K20 D3 Adaptor (RPC-1.00 male - female) |<br />

Adapter (RPC-1.00 Stecker - Kuppler)<br />

x01 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L1 with retractable male coupling nut |<br />

1<br />

L1 mit Stecker-Überwurfmutter<br />

L2 with retractable male coupling nut |<br />

1<br />

L2 mit Stecker-Überwurfmutter<br />

L3 with retractable male coupling nut |<br />

1<br />

L3 mit Stecker-Überwurfmutter<br />

Reflect standard |<br />

1<br />

Reflexions-Norm<br />

Reflect standard |<br />

1<br />

Reflexions-Norm<br />

DC to 22 GHz 1<br />

DC to 22 GHz 1<br />

with retractable male coupling nut |<br />

mit Stecker-Überwurfmutter<br />

with retractable female coupling nut |<br />

mit Kuppler-Überwurfmutter<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

6 mm wrench size / 0.35 Nm torque |<br />

6-mm-Schlüssel / 0.35-Nm-Drehmoment<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C,<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1 and L2<br />

0 22 110 f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1 and L3<br />

L1 and L2<br />

0 4.4 22<br />

110 f in GHz<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

51


<strong>Calibration</strong> Kits<br />

LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of lines<br />

used during the calibration<br />

procedure. If two lines are used the third line can be used as verification standard.<br />

The graph besides shows two possibilities using LRL with lowband loads. Without<br />

lowband loads the lower band<br />

cannot be calibrated.<br />

LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-) bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von Möglichkeiten, vektorielle Netzwerk-Analysatoren zu<br />

kalibrieren. Bei Verwendung von zwei Leitungen wird die dritte Leitung als Verifizier-<br />

Standard genutzt. Nebenstehende Grafik zeigt zwei mögliche LRLKalibrierungen mit<br />

Niedrigband-Lastabschlüssen. Ohne diese Abschlüsse kann der untere Frequenzbereich<br />

nicht kalibriert werden.<br />

52<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

53


<strong>Calibration</strong> Kits<br />

7-16, <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.15 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 8<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.2°<br />

≤ 2.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 8<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.07 dB<br />

≤ 0.12 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 8<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 0.8°<br />

≤ 1.5°<br />

DC to ≤ 4<br />

> 4 to ≤ 8<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 40 dB<br />

≥ 36 dB<br />

DC to ≤ 4<br />

>4 to ≤ 8<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.50 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 1.0 W (0° to 50° C)<br />

DC to 8<br />

Precision air lines 2 |<br />

Präzisions-Luftleitungen<br />

Return Loss | Rückflussdämpfung<br />

≥ 45 dB<br />

≥ 40 dB<br />

≥ 0.2 to ≤ 4<br />

> 4 to ≤ 8<br />

Characteristic Impedance | Wellenwiederstand<br />

50 Ω ± 0.10 Ω<br />

Adaptors | Adapter Return Loss | Rückflussdämpfung ≥ 36 dB<br />

≥ 26 dB<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

≥ 0.2 to ≤ 8<br />

DC to ≤ 4<br />

> 4 to ≤ 8<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. The characteristic impedance for the air lines is based on mechanical measurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

skin depth. Refer to the test report included in the kit for the exact dimensions of your<br />

precision air lines.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Characteristics.<br />

Individual values of connectors may deviate depending upon application,<br />

design, type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

2. Der angegebene Wellenwiderstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

"Skin-Effekts" frequenzabhängigen Wellenwiderstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

54<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: 7- 16 Right or Left (1col)<br />

<strong>Calibration</strong> Kit 7-16, Full Version<br />

<strong>Calibration</strong> Kit 7-16<br />

xOrdering Number<br />

Remarks<br />

x60 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x60 S 12L-12S D3 Open circuit/short circuit (male) |<br />

Leerlauf/Kurzschluss (Stecker)<br />

x60 K 12L-12S D3 Open circuit/short circuit (female) |<br />

Leerlauf/Kurzschluss (Kuppler)<br />

x60 S 17R-C01 D3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x60 K 17R-C01 D3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x60 S 101-S50 N1 Adaptor (7-16 male - male) |<br />

Adapter (7-16 Stecker - Stecker)<br />

x60 K 101-K50 N1 Adaptor (7-16 female - female) |<br />

Adapter (7-16 Kuppler - Kuppler)<br />

x05 S 160-S50 D3 Adaptor (RPC-N, 50 Ω male - 7–16 male) |<br />

Adapter (RPC-N, 50 Ω Stecker - 7–16 Stecker)<br />

x05 K 160-K50 D3 Adaptor (RPC-N, 50 Ω female - 7–16 female) |<br />

Adapter (RPC-N, 50 Ω Kuppler - 7–16 Kuppler)<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

one-piece open and short |<br />

Leerlauf-Kurzschluss-Komponente<br />

one-piece open and short |<br />

Leerlauf-Kurzschluss-Komponente<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

55


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: 7- 16 Right or Left (1col)<br />

<strong>Calibration</strong> Kit 7-16, Industrial Version<br />

<strong>Calibration</strong> Kit 7-16<br />

xOrdering Number<br />

Remarks<br />

x60 CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x60 S 12L-12S D3 Open circuit/short circuit (male) |<br />

Leerlauf/Kurzschluss (Stecker)<br />

x60 K 12L-12S D3 Open circuit/short circuit (female) |<br />

Leerlauf/Kurzschluss (Kuppler)<br />

x60 S 17R-C01 D3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x60 K 17R-C01 D3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

one-piece open and short |<br />

Leerlauf-Kurzschluss-Komponente<br />

one-piece open and short |<br />

Leerlauf-Kurzschluss-Komponente<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

56<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: 7- 16 Right or Left (1col)<br />

<strong>Calibration</strong> Kit 7-16, LRL Version<br />

<strong>Calibration</strong> Kit 7-16<br />

xOrdering Number<br />

Remarks<br />

x60 CK 120-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

LRL Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x60 S 101-K050 50 mm Air line (male - female) |<br />

50-mm-Luftleitung (Stecker - Kuppler)<br />

x60 S 101-K066 66 mm Air line (male - female) |<br />

66-mm-Luftleitung (Stecker - Kuppler)<br />

x60 S 101-K150 150 mm Air line (male - female) |<br />

150-mm-Luftleitung (Stecker - Kuppler)<br />

x60 S 101-K300 300 mm Air line (male - female) |<br />

300-mm-Luftleitung (Stecker - Kuppler)<br />

x60 S 12S-000 D3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x60 K 12S-000 D3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L1 1<br />

L2 1<br />

L3 1<br />

L4 verification standard |<br />

L4 Verifikations-Norm<br />

Reflect standard |<br />

Reflexions-Norm<br />

Reflect standard |<br />

Reflexions-Norm<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C, R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1 and L2<br />

0 1.3<br />

8<br />

f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1 and L3<br />

L1 and L2<br />

0 0.25 1.3<br />

8<br />

f in GHz<br />

LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of lines<br />

used during the calibration<br />

procedure. If two lines are used the third line can be used as verification standard.<br />

The graph besides shows two possibilities using LRL with lowband loads. Without<br />

lowband loads the lower band<br />

cannot be calibrated.<br />

LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-)bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von<br />

Möglichkeiten, vektorielle Netzwerk-Analysatoren zu kalibrieren. Bei Verwendung von<br />

zwei Leitungen wird die dritte Leitung als Verifizier-Standard genutzt. Nebenstehende<br />

Grafik zeigt zwei mögliche LRLKalibrierungen mit Niedrigband-Lastabschlüssen.<br />

Ohne diese Abschlüsse kann der untere Frequenzbereich nicht kalibriert werden.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

57


<strong>Calibration</strong> Kits<br />

BNC, 50 Ω <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.20 dB<br />

≤ 0.50 dB<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 3.0°<br />

≤ 5.0°<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.20 dB<br />

≤ 0.50 dB<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 2.5°<br />

≤ 4.0°<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 34 dB<br />

≥ 30 dB<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.50 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 1.0 W (0° to 50° C)<br />

Adaptors | Adapter Return Loss | Rückflussdämpfung ≥ 34 dB<br />

≥ 30 dB<br />

Adaptors | Adapter<br />

Return Loss | Rückflussdämpfung<br />

(N, 50 Ω /BNC, 50 Ω )<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

≥ 36 dB<br />

≥ 30 dB<br />

DC to 4<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

DC to ≤ 2<br />

> 2 to ≤ 4<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Characteristics.<br />

Individual values of connectors may deviate depending upon application,<br />

design, type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

58<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: BNC, 50 Right Ω or Left (1col)<br />

<strong>Calibration</strong> Kit BNC, 50 Ω , Full Version<br />

<strong>Calibration</strong> Kit BNC, 50 Ω<br />

xOrdering Number<br />

Remarks<br />

x51 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x51 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x51 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x51 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x51 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x51 S 170-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x51 K 170-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x51 S 121-S20 S3 Adaptor (BNC 50 Ω male - male) |<br />

Adapter (BNC 50 Ω Stecker - Stecker)<br />

x51 K 121-K20 S3 Adaptor (BNC 50 Ω female - female) |<br />

Adapter (BNC 50 Ω Kuppler - Kuppler)<br />

x05 S 151-S20 S3 Adaptor (RPC-N 50 Ω male - BNC 50 Ω male) |<br />

Adapter (RPC-N 50 Ω Stecker - BNC 50 Ω Stecker)<br />

x05 K 151-K20 S3 Adaptor (RPC-N 50 Ω female-BNC 50 Ω female) |<br />

Adapter (RPC-N 50 Ω Kuppler-BNC 50 Ω Kuppler)<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

59


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: BNC, 50 Right Ω or Left (1col)<br />

<strong>Calibration</strong> Kit BNC, 50 Ω , Industrial Version<br />

<strong>Calibration</strong> Kit BNC, 50 Ω<br />

xOrdering Number<br />

Remarks<br />

x51 CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x51 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x51 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x51 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x51 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x51 S 170-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x51 K 170-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

60<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

61


<strong>Calibration</strong> Kits<br />

F-Connectors, 75 Ω <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.17 dB<br />

≤ 0.20 dB<br />

DC to ≤ 3<br />

> 3 to ≤ 4<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.3°<br />

≤ 2.0°<br />

DC to ≤ 3<br />

> 3 to ≤ 4<br />

Short circuits 1 | Kurzschluss<br />

(male)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.17 dB<br />

≤ 0.20 dB<br />

DC to ≤ 3<br />

> 3 to ≤ 4<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.0°<br />

≤ 1.5°<br />

DC to ≤ 3<br />

> 3 to ≤ 4<br />

Broadband loads | Breitband-Last<br />

(male)<br />

Return Loss | Rückflussdämpfung<br />

≥ 34 dB<br />

≥ 30 dB<br />

DC to ≤ 3<br />

> 3 to ≤ 4<br />

Resistance | Gleichstrom-Widerstand<br />

75 Ω ± 0.75 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 4<br />

Precision air lines 2 |<br />

Präzisions-Luftleitungen<br />

Return Loss | Rückflussdämpfung<br />

≥ 40 dB<br />

≥ 35 dB<br />

≥ 0.1 to ≤ 3<br />

> 3 to ≤ 4<br />

Characteristic Impedance | Wellenwiederstand<br />

75 Ω ± 0.60 Ω<br />

≥ 0.1 to ≤ 4<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 32 dB<br />

≥ 28 dB<br />

DC to ≤ 3<br />

> 3 to ≤ 4<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

Adaptors | Adapter<br />

Return Loss | Rückflussdämpfung<br />

(N, 75 Ω /F)<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

2. The characteristic impedance for the air lines is based on mechanical measurements.<br />

The return loss specification includes the connector interfaces. The minimum<br />

frequency of the air lines is based on calculations of the impedance change due to<br />

skin depth. Refer to the test report included in the kit for the exact dimensions of your<br />

precision air lines.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Characteristics.<br />

Individual values of connectors may deviate depending upon application,<br />

design, type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.20 mm<br />

(±1.0 at 4 GHz)<br />

≥ 32 dB<br />

≥ 28 dB<br />

DC to ≤ 4<br />

DC to ≤ 3<br />

> 3 to ≤ 4<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

2. Der angegebene Wellenwiderstand für Luftleitungen basiert auf mechanischen<br />

Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.<br />

Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des<br />

"Skin-Effekts" frequenzabhängigen Wellenwiderstandes. Bitte beachten Sie den<br />

jedem Kalibrier-Kit beigelegten <strong>Test</strong>report.<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

62<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: F- Verbinder Right or Left (1col)<br />

<strong>Calibration</strong> Kit for F-Connectors, Full Version<br />

<strong>Calibration</strong> Kit F-Connectors<br />

xOrdering Number<br />

Remarks<br />

x74 CK 100-170 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x74 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x74 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x74 S 150-C10 CS Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x74 S 121-S20 S3 Adaptor (F male - male) |<br />

Adapter (F Stecker - Stecker)<br />

x74 K 121-K20 S3 Adaptor (F female - female) |<br />

Adapter (F Kuppler - Kuppler)<br />

xP5 S 174-S20 CS Adaptor (RPC-N 75 Ω male - F male) |<br />

Adapter (RPC-N 75 Ω Stecker - F Stecker)<br />

xP5 K 174-K20 CS Adaptor (RPC-N 75 Ω female - F female) |<br />

Adapter (RPC-N 75 Ω Kuppler - F Kuppler)<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

63


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: F- Verbinder Right or Left (1col)<br />

<strong>Calibration</strong> Kit for F-Connectors, Industrial Version<br />

<strong>Calibration</strong> Kit F-Connectors<br />

xOrdering Number<br />

Remarks<br />

x74 CK 10A-170 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x74 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x74 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x74 S 150-C10 CS Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

64<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: F- Verbinder Right or Left (1col)<br />

<strong>Calibration</strong> Kit for F-Connectors, TRL Version<br />

<strong>Calibration</strong> Kit F-Connectors<br />

xOrdering Number<br />

Remarks<br />

x74 CK 120-170 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

TRL Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x74 S 101-K031 31.2 mm Air line (male - female) |<br />

31.2-mm-Luftleitung (Stecker - Kuppler)<br />

x74 S 101-K150 150 mm Air line (male - female) |<br />

150-mm-Luftleitung (Stecker - Kuppler)<br />

x74 S 101-K100 100 mm Air line (male - female) |<br />

100-mm-Luftleitung (Stecker - Kuppler)<br />

x74 S 12S-001 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x74 K 12S-001 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

L2 1<br />

L3 1<br />

L4 verification standard |<br />

L4 Verifikations-Norm<br />

Reflect standard |<br />

Reflexions-Norm<br />

Reflect standard |<br />

Reflexions-Norm<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C,<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

Frequency Range (2 Bands)<br />

Lowband loads<br />

L1=Thru and L2<br />

0 0.8<br />

4<br />

f in GHz<br />

Frequency Range (3 Bands)<br />

Lowband loads<br />

L1=Thru and L3<br />

L1=Thru and L2<br />

0 0.16 0.8<br />

4<br />

f in GHz<br />

TRL/LRL calibrations without lowband loads are band limited. There are many different<br />

possibilities to calibrate a VNA depending from the line length and the number of<br />

lines used during the calibration procedure. If two lines are used the third line can be<br />

used as verification<br />

standard. The graph besides shows two possibilities using TRL with lowband loads.<br />

Without lowband loads the lower band cannot be calibrated. In this calibration kit line<br />

1 (L1) is the zero length thru connection.<br />

TRL/LRL-Kalibrierungen ohne Niedrigfrequenz-Lastabschlüsse sind (frequenz-) bandlimitiert.<br />

Abhängig von der Länge und der Anzahl der bei der Kalibrierung eingesetzten<br />

Leitungen gibt es eine Reihe von Möglichkeiten, vektorielle Netzwerk-<br />

Analysatoren zu kalibrieren. Bei Verwendung von zwei Leitungen wird die dritte Leitung<br />

als Verifizier-Standard genutzt. Nebenstehende Grafik zeigt zwei mögliche TRL-<br />

Kalibrierungen mit Niedrigband-Lastabschlüssen. Ohne diese Abschlüsse kann der<br />

untere Frequenzbereich nicht kalibriert werden. In diesem Kalibrier-Kit ist die Leitung<br />

1 (L1) eine Thru-Leitung mit Länge Null.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

65


<strong>Calibration</strong> Kits<br />

QMA <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.15 dB<br />

≤ 0.25 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 2.5°<br />

≤ 4.5°<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.15 dB<br />

≤ 0.20 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 2.2°<br />

≤ 4.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 36 dB<br />

≥ 26 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.50 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 18<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 32 dB<br />

≥ 24 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

(RPC-3.50/QMA)<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

Return Loss | Rückflussdämpfung<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Characteristics.<br />

Individual values of connectors may deviate depending upon application,<br />

design, type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.25 mm<br />

(±5.4° at 18 GHz)<br />

≥ 32 dB<br />

≥ 24 dB<br />

DC to 18<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

±0.25 mm<br />

DC to 18<br />

(±5.4° at 18 GHz)<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

66<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: QMA Right or Left (1col)<br />

<strong>Calibration</strong> Kit QMA, Full Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

x28 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x28 S 12L-000 N3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x28 K 12L-000 N3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x28 S 12S-000 N3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x28 K 12S-000 N3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x28 S 150-C10 N3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x28 K 150-C10 N3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x03 S 128-S20 N3 Adaptor (RPC-3.50 male - QMA male) |<br />

Adapter (RPC-3.50 Stecker - QMA Stecker)<br />

x03 S 128-K20 N3 Adaptor (RPC-3.50 male - QMA female) |<br />

Adapter (RPC-3.50 Stecker - QMA Kuppler)<br />

x03 K 128-S20 N3 Adaptor (RPC-3.50 female - QMA male) |<br />

Adapter (RPC-3.50 Kuppler - QMA Stecker)<br />

x03 K 128-K20 N3 Adaptor (RPC-3.50 female - QMA female) |<br />

Adapter (RPC-3.50 Kuppler - QMA Kuppler)<br />

x28 S 121-S20 N3 Adaptor (QMA male-male) |<br />

Adapter (QMA Stecker-Stecker)<br />

x28 S 121-K20 N3 Adaptor (QMA male-female) |<br />

Adapter (QMA Stecker-Kuppler)<br />

x28 K 121-K20 N3 Adaptor (QMA female-female) |<br />

Adapter (QMA Kuppler-Kuppler)<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

67


<strong>Calibration</strong> Kits<br />

SMP <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.25 dB<br />

≤ 0.40 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 3.0°<br />

≤ 5.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.20 dB<br />

≤ 0.30 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 2.5°<br />

≤ 4.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 26 dB<br />

≥ 23 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.50 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 18<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 26 dB<br />

≥ 20 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

Adaptors RPC-2.92 / SMP |<br />

Adapter RPC-2.92 / SMP<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

Return Loss | Rückflussdämpfung<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Characteristics.<br />

Individual values of connectors may deviate depending upon application,<br />

design, type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.20 mm<br />

(±4.3° at 18 GHz)<br />

≥ 32 dB<br />

≥ 26 dB<br />

≥ 21dB<br />

DC to 18<br />

DC to ≤ 12<br />

>12 to ≤ 26.5<br />

> 26.5 to ≤ 40<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

68<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrierkits Masterpage-Wechsel: SMP Right or Left (1col)<br />

<strong>Calibration</strong> Kit SMP, Industrial Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

x19 CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x19 S 10L-000 D3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x19 K 10L-000 D3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x19 S 10S-000 D3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x19 K 10S-000 D3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x19 S 150-C10 D3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x19 K 150-C10 D3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x19 S 101-S20 D3 Adaptor (SMP male - male) |<br />

Adapter (SMP Stecker - Stecker)<br />

x19 K 101-K20 D3 Adaptor (SMP female - female) |<br />

Adapter (SMP Kuppler - Kuppler)<br />

x19 S 101-K20 D3 Adaptor (SMP male - female) |<br />

Adapter (SMP Stecker - Kuppler)<br />

x02 S 119-S00 E3 Adaptor (RPC-2.92 male - SMP male) |<br />

Adapter (RPC-2.92 Stecker - SMP Stecker)<br />

x02 K 119-K00 E3 Adaptor (RPC-2.92 female - SMP female) |<br />

Adapter (RPC-2.92 Kuppler - SMP Kuppler)<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

69


<strong>Calibration</strong> Kits<br />

SnapN <strong>Calibration</strong> Standards<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.20 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 11<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.5°<br />

≤ 3.0°<br />

DC to ≤ 4<br />

> 4 to ≤ 11<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.10 dB<br />

≤ 0.15 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 11<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 1.2°<br />

≤ 2.5°<br />

DC to ≤ 4<br />

> 4 to ≤ 11<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 40 dB<br />

≥ 30 dB<br />

DC to ≤ 4<br />

>4 to ≤ 11<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.50 Ω<br />

DC<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

(SnapN/RPC-N 50 Ω )<br />

Power Handling | Nennleistung<br />

Return Loss | Rückflussdämpfung<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

1. The specifications for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

≤ 0.5 W (0° to 50° C)<br />

≥ 36 dB<br />

≥ 27 dB<br />

DC to 11<br />

DC to ≤ 4<br />

> 4 to ≤ 11<br />

± 0.2 mm<br />

DC to 11<br />

(± 2.7° at 11 GHz)<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

70<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Kalibrier- Masterpage-Wechsel: Kits für SnapN Right or Left (1col)<br />

<strong>Calibration</strong> Kit SnapN, Industrial Version<br />

<strong>Calibration</strong> Kit SnapN<br />

xOrdering Number<br />

Remarks<br />

x53Q CK 10A-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Industrial Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x53 QS 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x53 QK 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x53 QS 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x53 QK 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x53 QS 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x53 QK 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x53 QS 105-K20 S3 Adaptor (SnapN male - RPC-N 50Ω female) |<br />

Adapter (SnapN Stecker - RPC-N 50Ω Kuppler)<br />

x53 QK 105-S20 S3 Adaptor (SnapN female - RPC-N 50Ω male) |<br />

Adapter (SnapN Kuppler - RPC-N 50Ω Stecker)<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

71


<strong>Calibration</strong> Kits<br />

<strong>Calibration</strong> Kit FAKRA-RF<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

Open circuits 1 | Leerlauf<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.05 dB<br />

≤ 0.10 dB<br />

≤ 0.12 dB<br />

DC to ≤ 1<br />

> 1 to ≤ 3<br />

> 3 to ≤ 6<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 0.5°<br />

≤ 1.5°<br />

≤ 2.2°<br />

DC to ≤ 1<br />

> 1 to ≤ 3<br />

> 3 to ≤ 6<br />

Short circuits 1 | Kurzschluss<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≤ 0.05 dB<br />

≤ 0.10 dB<br />

≤ 0.12 dB<br />

DC to ≤ 1<br />

> 1 to ≤ 3<br />

> 3 to ≤ 6<br />

Deviation from Nominal Phase |<br />

Nominale Phasenabweichung<br />

≤ 0.5°<br />

≤ 1.2°<br />

≤ 1.8°<br />

DC to ≤ 1<br />

> 1 to ≤ 3<br />

> 3 to ≤ 6<br />

Broadband loads | Breitband-Last<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

≥ 42 dB<br />

≥ 40 dB<br />

≥ 36 dB<br />

DC to ≤ 1<br />

> 1 to ≤ 3<br />

> 3 to ≤ 6<br />

Resistance | Gleichstrom-Widerstand<br />

50 Ω ± 0.50 Ω<br />

DC<br />

Power Handling | Nennleistung<br />

≤ 0.5 W (0° to 50° C)<br />

DC to 6<br />

Adaptors, phase matched |<br />

Adapter, phasenangepasst<br />

Return Loss | Rückflussdämpfung<br />

≥ 38 dB<br />

≥ 26 dB<br />

≥ 21 dB<br />

DC to ≤ 1<br />

> 1 to ≤ 3<br />

> 3 to ≤ 6<br />

Accuracy of Electrical Length |<br />

Toleranz elektrische Länge<br />

1. The specification for the opens and shorts are given as allowed deviation from the<br />

nominal model as defined in the test report included in the kit.<br />

<strong>Rosenberger</strong> connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

±0.4 mm<br />

DC to 6<br />

(±2.9° at 6 GHz)<br />

1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale<br />

Phasenabweichung wie im <strong>Test</strong>report angegeben (im Kalibrier-Kit enthalten).<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

72<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Calibration</strong> Kits<br />

Coaxial <strong>Calibration</strong> Kits FAKRA- RF<br />

<strong>Calibration</strong> Kit FAKRA-RF, Full Version<br />

<strong>Calibration</strong> Kit<br />

xOrdering Number<br />

Remarks<br />

x59 CK 100-150 <strong>Rosenberger</strong> calibration kits are delivered in stable wooden boxes including test reports. |<br />

Lieferung von Kalibrier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report.<br />

Full Version<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Please use the following part numbers for ordering single components.<br />

Bitte folgende Artikel-Nummern für Nachbestellungen von Einzel-Komponenten verwenden.<br />

Contents of <strong>Calibration</strong> Kit<br />

Inhalt des Kalibrier-Kits<br />

xOrdering Number Components Remarks Quantity<br />

x03 S 12L-000 S3 Open circuit (male) |<br />

Leerlauf (Stecker)<br />

x03 K 12L-000 S3 Open circuit (female) |<br />

Leerlauf (Kuppler)<br />

x03 S 12S-000 S3 Short circuit (male) |<br />

Kurzschluss (Stecker)<br />

x03 K 12S-000 S3 Short circuit (female) |<br />

Kurzschluss (Kuppler)<br />

x03 S 150-C10 S3 Broadband load (male) |<br />

Breitband-Last (Stecker)<br />

x03 K 150-C10 S3 Broadband load (female) |<br />

Breitband-Last (Kuppler)<br />

x03 K 159-S20 S3 Adaptor (RPC-3.50 female - FAKRA RF male) |<br />

Adapter (RPC-3.50 Kuppler - FAKRA HF Stecker)<br />

x03 K 159-K20 S3 Adaptor (RPC-3.50 female - FAKRA RF female) |<br />

Adapter (RPC-3.50 Kuppler - FAKRA HF Kuppler)<br />

x03 S 159-S20 S3 Adaptor (RPC-3.50 male - FAKRA RF male) |<br />

Adapter (RPC-3.50 Stecker - FAKRA HF Stecker)<br />

x03 S 159-K20 S3 Adaptor (RPC-3.50 male - FAKRA RF female) |<br />

Adapter (RPC-3.50 Stecker - FAKRA HF Kuppler)<br />

x03 W 021-000 Torque wrench |<br />

Drehmomentschlüssel<br />

x59 Z 014-000 Z Plastic housing male |<br />

Kunststoff-Gehäuse Stecker<br />

x59 Z 013-000 Z Plastic housing female |<br />

Kunststoff-Gehäuse Kuppler<br />

x- 3 1/2" disk on request |<br />

3 1/2"-Diskette auf Anfrage<br />

RPC-3.50 Interface 1<br />

RPC-3.50 Interface 1<br />

RPC-3.50 Interface 1<br />

RPC-3.50 Interface 1<br />

RPC-3.50 Interface 1<br />

RPC-3.50 Interface 1<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

phase matched |<br />

phasenangepasst<br />

8 mm wrench size / 0.9 Nm torque |<br />

8-mm-Schlüssel / 0.9 Nm Drehmoment<br />

Spare Housing |<br />

Ersatzgehäuse<br />

Spare Housing |<br />

Ersatzgehäuse<br />

Disk available for the following network analyzers: |<br />

Diskette verfügbar für folgende Netzwerk-Analysatoren:<br />

A1: HP 8510C<br />

A2: HP 8752D/8753D<br />

W2: Anritsu 37XXXA/B<br />

R1: R&S ZVA/ZVB/ZVK/ZVM/ZVR/ZVT<br />

1<br />

1<br />

1<br />

1<br />

1<br />

10<br />

10<br />

1<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

73


Verification Kits<br />

3Verification Kits<br />

Verification Kit RPC-N, 50 Ω<br />

Each verification device is electrically characterized on a network analyzer measurement<br />

system. These measurements are traceable to the Physikalisch-Technische<br />

Bundesanstalt Braunschweig (PTB) through mechanical and electrical paths.<br />

Alle Verifizier-Komponenten werden mit einem Netzwerk-Analysator elektrisch geprüft<br />

und charakterisiert. Die Messungen sind rückführbar auf Normale der Physikalisch-<br />

Technischen Bundesanstalt Braunschweig (PTB).<br />

Verification Kit<br />

xOrdering Number<br />

x05 CK 200-150<br />

Remarks<br />

<strong>Rosenberger</strong> verification kits are delivered in stable wooden boxes including test reports and network analyzer<br />

measurements. |<br />

Lieferung von Verifizier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report und Messprotokoll.<br />

RPC-N, 50 Ω<br />

Contents of Verification Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Verifizier-Kits<br />

x05 AS 122-K20 S3 20 dB Attenuator | Dämpfungsglied 1 Please use this part numbers for ordering single components.<br />

|<br />

x05 AS 122-K40 S3 40 dB Attenuator | Dämpfungsglied 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

x05 S 101-K100 50 Ω Air line | Luftleitung 1<br />

Einzel-Komponenten verwenden.<br />

x05 S 102-K100 25 Ω Mismatch air line | Fehlabschluss-Luftleitung 1<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

20 dB Attenuator |<br />

20-dB-Dämpfungsglied<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 32 dB<br />

≥ 26 dB<br />

20 dB ± 0.30 dB<br />

20 dB ± 0.50 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

40 dB Attenuator |<br />

40-dB-Dämpfungsglied<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 32 dB<br />

≥ 23 dB<br />

40 dB ± 0.50 dB<br />

40 dB ± 1.00 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

0.3 to ≤ 4<br />

> 4 to ≤ 18<br />

0.04 to ≤ 4<br />

> 4 to ≤ 18<br />

50 Ω Air line |<br />

50-Ω -Luftleitung<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 40 dB<br />

≥ 35 dB<br />

≤ 0.08 dB<br />

≤ 0.15 dB<br />

50 Ω Air line<br />

Outer Conductor | Außenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

Inner Conductor | Innenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

25 Ω Mismatch air line<br />

Outer Conductor | Außenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

Inner Conductor | Innenleiter:<br />

Diameter | Durchmesser<br />

-50 Ω Section | Abschnitt<br />

-25 Ω Section | Abschnitt<br />

Length | Länge<br />

-Total<br />

-25 Ω Section | Abschnitt<br />

7.000 mm ± 0.005 mm<br />

100.00 mm + 0.02 mm<br />

3.040 mm ± 0.010 mm<br />

100.00 mm - 0.02 mm<br />

25 Ω Mismatch air line |<br />

25-Ω -Fehlabschluss-Luftleitung<br />

(male and female)<br />

7.000 mm ± 0.005 mm<br />

100.00 mm + 0.02 mm<br />

3.040 mm ± 0.010 mm<br />

4.615 mm ± 0.010 mm<br />

100.00 mm - 0.02 mm<br />

75.00 mm ± 0.05 mm<br />

74<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Verification Kits<br />

Verification Kit RPC-7<br />

Each verification device is electrically characterized on a network analyzer measurement<br />

system. These measurements are traceable to the Physikalisch-Technische<br />

Bundesanstalt Braunschweig (PTB) through mechanical and electrical paths.<br />

Alle Verifizier-Komponenten werden mit einem Netzwerk-Analysator elektrisch geprüft<br />

und charakterisiert. Die Messungen sind rückführbar auf Normale der Physikalisch-<br />

Technischen Bundesanstalt Braunschweig (PTB).<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Verification Kit<br />

xOrdering Number<br />

x07 CK 200-150<br />

Remarks<br />

<strong>Rosenberger</strong> verification kits are delivered in stable wooden boxes including test reports and network analyzer<br />

measurements. |<br />

Lieferung von Verifizier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report und Messprotokoll.<br />

RPC-7<br />

Contents of Verification Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Verifizier-Kits<br />

x07 AP 122-P20 S3 20 dB Attenuator | Dämpfungsglied 1 Please use this part numbers for ordering single components.<br />

|<br />

x07 AP 122-P40 S3 40 dB Attenuator | Dämpfungsglied 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

x07 P 101-P100 50 Ω Air line | Luftleitung 1<br />

Einzel-Komponenten verwenden.<br />

x07 P 102-P100 25 Ω Mismatch air line | Fehlabschluss-Luftleitung 1<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

20 dB Attenuator |<br />

20-dB-Dämpfungsglied<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 26 dB<br />

≥ 23 dB<br />

20 dB ± 0.30 dB<br />

20 dB ± 0.80 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

40 dB Attenuator |<br />

40-dB-Dämpfungsglied<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 26 dB<br />

≥ 20 dB<br />

40 dB ± 0.80 dB<br />

40 dB ± 1.50 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

DC to ≤ 4<br />

> 4 to ≤ 18<br />

0.3 to ≤ 4<br />

> 4 to ≤ 18<br />

0.04 to ≤ 4<br />

> 4 to ≤ 18<br />

50 Ω Air line |<br />

50-Ω -Luftleitung<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 45 dB<br />

≥ 40 dB<br />

≤ 0.08 dB<br />

≤ 0.15 dB<br />

50 Ω Air line<br />

Outer Conductor | Außenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

Inner Conductor | Innenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

25 Ω Mismatch air line<br />

Outer Conductor | Außenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

Inner Conductor | Innenleiter:<br />

Diameter | Durchmesser<br />

-50 Ω Section | Abschnitt<br />

-25 Ω Section | Abschnitt<br />

Length | Länge<br />

-Total<br />

-25 Ω Section | Abschnitt<br />

7.000 mm ± 0.005 mm<br />

100.00 mm + 0.02 mm<br />

3.040 mm ± 0.005 mm<br />

100.00 mm - 0.02 mm<br />

25 Ω Mismatch air line |<br />

25-Ω -Fehlabschluss-Luftleitung<br />

(male and female)<br />

7.000 mm ± 0.005 mm<br />

100.00 mm + 0.02 mm<br />

3.040 mm ± 0.005 mm<br />

4.615 mm ± 0.005 mm<br />

100.00 mm - 0.02 mm<br />

75.00 mm ± 0.02 mm<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

75


Verification Kits<br />

Verification Kit RPC-3.50<br />

Each verification device is electrically characterized on a network analyzer measurement<br />

system. These measurements are traceable to the Physikalisch-Technische<br />

Bundesanstalt Braunschweig (PTB) through mechanical and electrical paths.<br />

Alle Verifizier-Komponenten werden mit einem Netzwerk-Analysator elektrisch geprüft<br />

und charakterisiert. Die Messungen sind rückführbar auf Normale der Physikalisch-<br />

Technischen Bundesanstalt Braunschweig (PTB).<br />

Verification Kit<br />

xOrdering Number<br />

x03 CK 200-150<br />

Remarks<br />

<strong>Rosenberger</strong> verification kits are delivered in stable wooden boxes including test reports and network analyzer<br />

measurements. |<br />

Lieferung von Verifizier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report und Messprotokoll.<br />

RPC-3.50<br />

Contents of Verification Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Verifizier-Kits<br />

x03 AS 122-K20 S3 20 dB Attenuator | Dämpfungsglied 1 Please use this part numbers for ordering single components.<br />

|<br />

x03 AS 122-K40 S3 40 dB Attenuator | Dämpfungsglied 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

x03 S 101-K100 50 Ω Air line | Luftleitung 1<br />

Einzel-Komponenten verwenden.<br />

x03 S 102-K100 25 Ω Mismatch air line | Fehlabschluss-Luftleitung 1<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

20 dB Attenuator |<br />

20-dB-Dämpfungsglied<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 26 dB<br />

≥ 20 dB<br />

20 dB ± 0.30 dB<br />

20 dB ± 0.50 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 26.5<br />

DC to ≤ 4<br />

> 4 to ≤ 26.5<br />

40 dB Attenuator |<br />

40-dB-Dämpfungsglied<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 26 dB<br />

≥ 20 dB<br />

40 dB ± 0.40 dB<br />

40 dB ± 1.00 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 26.5<br />

DC to ≤ 4<br />

> 4 to ≤ 26.5<br />

0.3 to ≤ 4<br />

> 4 to ≤ 26.5<br />

0.04 to ≤ 4<br />

> 4 to ≤ 26.5<br />

50 Ω Air line |<br />

50-Ω -Luftleitung<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 40 dB<br />

≥ 35 dB<br />

≤ 0.15 dB<br />

≤ 0.30 dB<br />

50 Ω Air line<br />

Outer Conductor | Außenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

Inner Conductor | Innenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

25 Ω Mismatch air line<br />

Outer Conductor | Außenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

Inner Conductor | Innenleiter:<br />

Diameter | Durchmesser<br />

-50 Ω Section | Abschnitt<br />

-25 Ω Section | Abschnitt<br />

Length | Länge<br />

-Total<br />

-25 Ω Section | Abschnitt<br />

3.500 mm ± 0.005 mm<br />

100.00 mm + 0.02 mm<br />

1.520 mm ± 0.010 mm<br />

100.00 mm - 0.02 mm<br />

25 Ω Mismatch air line |<br />

25-Ω -Fehlabschluss-Luftleitung<br />

(male and female)<br />

3.500 mm ± 0.005 mm<br />

100.00 mm + 0.02 mm<br />

1.520 mm ± 0.010 mm<br />

2.307 mm ± 0.007 mm<br />

100.00 mm - 0.02 mm<br />

75.00 mm ± 0.050 mm<br />

76<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Verification Kits<br />

Verification Kit RPC-2.92<br />

Each verification device is electrically characterized on a network analyzer measurement<br />

system. These measurements are traceable to the Physikalisch-Technische<br />

Bundesanstalt Braunschweig (PTB) through mechanical and electrical paths.<br />

Alle Verifizier-Komponenten werden mit einem Netzwerk-Analysator elektrisch geprüft<br />

und charakterisiert. Die Messungen sind rückführbar auf Normale der Physikalisch-<br />

Technischen Bundesanstalt Braunschweig (PTB).<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Verification Kit<br />

xOrdering Number<br />

x02 CK 200-150<br />

Remarks<br />

<strong>Rosenberger</strong> verification kits are delivered in stable wooden boxes including test reports and network analyzer<br />

measurements. |<br />

Lieferung von Verifizier-Kits erfolgt in stabiler Holzbox einschließlich <strong>Test</strong>report und Messprotokoll.<br />

RPC-2.92<br />

Contents of Verification Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Verifizier-Kits<br />

x02 AS 122-K20 S3 20 dB Attenuator | Dämpfungsglied 1 Please use this part numbers for ordering single components.<br />

|<br />

x02 AS 122-K40 S3 40 dB Attenuator | Dämpfungsglied 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

x02 S 101-K075 50 Ω Air line | Luftleitung 1<br />

Einzel-Komponenten verwenden.<br />

x02 S 102-K075 25 Ω Mismatch air line | Fehlabschluss-Luftleitung 1<br />

Electrical Specifications<br />

Devices |<br />

Komponenten<br />

Parameters |<br />

Parameter<br />

Specifications |<br />

Spezifikation<br />

Frequency range in GHz |<br />

Frequenzbereich in GHz<br />

20 dB Attenuator |<br />

20-dB-Dämpfungsglied<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 32 dB<br />

≥ 20.1 dB<br />

20 dB ± 0.30 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 40<br />

DC to ≤ 40<br />

40 dB Attenuator |<br />

40-dB-Dämpfungsglied<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 32 dB<br />

≥ 20.1 dB<br />

40 dB ± 0.40 dB<br />

40 dB ± 0.80 dB<br />

DC to ≤ 4<br />

> 4 to ≤ 40<br />

DC to ≤ 4<br />

> 4 to ≤ 40<br />

50 Ω Air line<br />

50-Ω -Luftleitung<br />

(male and female)<br />

Return Loss | Rückflussdämpfung<br />

Return Loss | Rückflussdämpfung<br />

Insertion Loss | Dämpfung<br />

≥ 38 dB<br />

≥ 30 dB<br />

≤ 0.38 dB<br />

0.3 to ≤ 4<br />

> 4 to ≤ 40<br />

0.3 to ≤ 40<br />

50 Ω Air line<br />

Outer Conductor | Außenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

Inner Conductor | Innenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

2.9235 mm ± 0.005 mm<br />

75.00 mm + 0.02 mm<br />

1.270 mm ± 0.005 mm<br />

75.00 mm - 0.02 mm<br />

25 Ω Mismatch air line |<br />

25-Ω -Fehlabschluss-Luftleitung<br />

(male and female)<br />

25 Ω Mismatch air line<br />

Outer Conductor | Außenleiter:<br />

Diameter | Durchmesser<br />

Length | Länge<br />

Inner Conductor | Innenleiter:<br />

Diameter | Durchmesser<br />

-50 Ω Section | Abschnitt<br />

-25 Ω Section | Abschnitt<br />

Length | Länge<br />

-Total<br />

-25 Ω Section | Abschnitt<br />

2.9235 mm ± 0.005 mm<br />

75.00 mm + 0.02 mm<br />

1.270 mm ± 0.007 mm<br />

1.927 mm ± 0.005 mm<br />

75.00 mm - 0.02 mm<br />

50.00 mm ± 0.050 mm<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

77


Gauge Kits<br />

4Gauge Kits<br />

Gauge Kit RPC-N 50 Ω<br />

Gauge Kit<br />

xOrdering Number<br />

x05 GK 0KS-000<br />

Remarks<br />

<strong>Rosenberger</strong> gauge kits are delivered in stable wooden box with gauge male/female incl. gauge block male/<br />

female. |<br />

Lieferung von Messuhren-Kits erfolgt in stabiler Holzbox, Messuhren einschließlich Kalibrier-Blocks.<br />

RPC-N 50 Ω<br />

Contents of Gauge Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Messuhren-Kits<br />

x05 W 00S-000 Gauge male incl. block 1 Please use this part numbers for ordering single components.<br />

|<br />

x05 W 00K-000 Gauge female incl. block 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

Einzel-Komponenten verwenden.<br />

Mechanical Specifications<br />

Mechanical data | Mechanische Daten<br />

Gauge range ± 500 µm<br />

Gauge scale gradation 1 µm<br />

Gauge accuracy 5 µm<br />

Gauge block flatness ≤ 2 µm<br />

Gauge block surface finish ≤ 0.2 µm<br />

78<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Gauge Kits<br />

Gauge Kit RPC-N 75 Ω<br />

Gauge Kit<br />

xOrdering Number<br />

xP5 GK 0KS-000<br />

Remarks<br />

<strong>Rosenberger</strong> gauge kits are delivered in stable wooden box with gauge male/female incl. gauge block male/<br />

female. |<br />

Lieferung von Messuhren-Kits erfolgt in stabiler Holzbox, Messuhren einschließlich Kalibrier-Blocks.<br />

RPC-N 75 Ω<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Contents of Gauge Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Messuhren-Kits<br />

xP5 W 00S-000 Gauge male incl. block 1 Please use this part numbers for ordering single components.<br />

|<br />

x05 W 00K-000 Gauge female incl. block 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

Einzel-Komponenten verwenden.<br />

Mechanical Specifications<br />

Mechanical data | Mechanische Daten<br />

Gauge range ± 500 µm<br />

Gauge scale gradation 1 µm<br />

Gauge accuracy 5 µm<br />

Gauge block flatness ≤ 2 µm<br />

Gauge block surface finish ≤ 0.2 µm<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

79


Gauge Kits<br />

Gauge Kit RPC-TNC<br />

Gauge Kit<br />

xOrdering Number<br />

x06 GK 0KS-000<br />

Remarks<br />

<strong>Rosenberger</strong> gauge kits are delivered in stable wooden box with gauge male/female incl. gauge block male/<br />

female. |<br />

Lieferung von Messuhren-Kits erfolgt in stabiler Holzbox, Messuhren einschließlich Kalibrier-Blocks.<br />

RPC-TNC<br />

Contents of Gauge Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Messuhren-Kits<br />

x06 W 00S-000 Gauge male incl. block 1 Please use this part numbers for ordering single components.<br />

|<br />

x06 W 00K-000 Gauge female incl. block 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

Einzel-Komponenten verwenden.<br />

Mechanical Specifications<br />

Mechanical data | Mechanische Daten<br />

Gauge range ± 500 µm<br />

Gauge scale gradation 1 µm<br />

Gauge accuracy 5 µm<br />

Gauge block flatness ≤ 2 µm<br />

Gauge block surface finish ≤ 0.2 µm<br />

80<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Gauge Kits<br />

Gauge Kit RPC-7<br />

Gauge Kit<br />

xOrdering Number<br />

Remarks<br />

x07 GK 0KS-000 <strong>Rosenberger</strong> gauge kits are delivered in stable wooden box with gauge incl. gauge block. |<br />

Lieferung von Messuhren-Kits erfolgt in stabiler Holzbox, Messuhr einschließlich Kalibrier-Block.<br />

RPC-7<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Contents of Gauge Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Messuhren-Kits<br />

x07 W 001-000 Gauge incl. block 1 Please use this part number for ordering single components.<br />

|<br />

Bitte diese Artikel-Nummer für Nachbestellungen von<br />

Einzel-Komponenten verwenden.<br />

Mechanical Specifications<br />

Mechanical data | Mechanische Daten<br />

Gauge range ± 500 µm<br />

Gauge scale gradation 1 µm<br />

Gauge accuracy 5 µm<br />

Gauge block flatness ≤ 2 µm<br />

Gauge block surface finish ≤ 0.2 µm<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

81


Gauge Kits<br />

Gauge Kit RPC-3.50 / RPC-2.92<br />

Gauge Kit<br />

xOrdering Number<br />

x03 GK 0KS-000<br />

Remarks<br />

<strong>Rosenberger</strong> gauge kits are delivered in stable wooden box with gauge male/female incl. gauge block male/<br />

female. |<br />

Lieferung von Messuhren-Kits erfolgt in stabiler Holzbox, Messuhren einschließlich Kalibrier-Blocks.<br />

RPC-3.50 / RPC-2.92<br />

Contents of Gauge Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Messuhren-Kits<br />

x03 W 00S-000 Gauge male incl. block 1 Please use this part numbers for ordering single components.<br />

|<br />

x03 W 00K-000 Gauge female incl. block 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

Einzel-Komponenten verwenden.<br />

Mechanical Specifications<br />

Mechanical data | Mechanische Daten<br />

Gauge range ± 500 µm<br />

Gauge scale gradation 1 µm<br />

Gauge accuracy 5 µm<br />

Gauge block flatness ≤ 2 µm<br />

Gauge block surface finish ≤ 0.2 µm<br />

82<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Gauge Kits<br />

Gauge Kit RPC-2.40 / RPC-1.85<br />

Gauge Kit<br />

xOrdering Number<br />

x08 GK 0KS-000<br />

Remarks<br />

<strong>Rosenberger</strong> gauge kits are delivered in stable wooden box with gauge male/female incl. gauge block male/<br />

female. |<br />

Lieferung von Messuhren-Kits erfolgt in stabiler Holzbox, Messuhren einschließlich Kalibrier-Blocks.<br />

RPC-2.40 / RPC-1.85<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Contents of Gauge Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Messuhren-Kits<br />

x08 W 00S-000 Gauge male incl. block 1 Please use this part numbers for ordering single components.<br />

|<br />

x08 W 00K-000 Gauge female incl. block 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

Einzel-Komponenten verwenden.<br />

Mechanical Specifications<br />

Mechanical data | Mechanische Daten<br />

Gauge range ± 500 µm<br />

Gauge scale gradation 1 µm<br />

Gauge accuracy 5 µm<br />

Gauge block flatness ≤ 2 µm<br />

Gauge block surface finish ≤ 0.2 µm<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

83


Gauge Kits<br />

Gauge Kit RPC-1.00<br />

Gauge Kit<br />

xOrdering Number<br />

x01 GK 0KS-000<br />

Remarks<br />

<strong>Rosenberger</strong> gauge kits are delivered in stable wooden box with gauge male/female incl. gauge block male/<br />

female. |<br />

Lieferung von Messuhren-Kits erfolgt in stabiler Holzbox, Messuhren einschließlich Kalibrier-Blocks.<br />

RPC-1.00<br />

Contents of Gauge Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Messuhren-Kits<br />

x01 W 00S-000 Gauge male incl. block 1 Please use this part numbers for ordering single components.<br />

|<br />

x01 W 00K-000 Gauge female incl. block 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

Einzel-Komponenten verwenden.<br />

Mechanical Specifications<br />

Mechanical data | Mechanische Daten<br />

Gauge range ± 500 µm<br />

Gauge scale gradation 1 µm<br />

Gauge accuracy 5 µm<br />

Gauge block flatness ≤ 2 µm<br />

Gauge block surface finish ≤ 0.2 µm<br />

84<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Gauge Kits<br />

Gauge Kit RPC-7-16<br />

Gauge Kit 7-16<br />

xOrdering Number<br />

x60 GK 0KS-000<br />

Remarks<br />

<strong>Rosenberger</strong> gauge kits are delivered in stable wooden box with gauge male/female incl. gauge block male/<br />

female. |<br />

Lieferung von Messuhren-Kits erfolgt in stabiler Holzbox, Messuhren einschließlich Kalibrier-Blocks.<br />

<strong>Test</strong> & <strong>Measurement</strong><br />

Kits<br />

Contents of Gauge Kit<br />

xOrdering Number Components Quantity Remarks<br />

Inhalt des Messuhren-Kits<br />

x60 W 00S-000 Gauge male incl. block 1 Please use this part numbers for ordering single components.<br />

|<br />

x60 W 00K-000 Gauge female incl. block 1<br />

Bitte diese Artikel-Nummern für Nachbestellungen von<br />

Einzel-Komponenten verwenden.<br />

Mechanical Specifications<br />

Mechanical data | Mechanische Daten<br />

Gauge range ± 500 µm<br />

Gauge scale gradation 1 µm<br />

Gauge accuracy 5 µm<br />

Gauge block flatness ≤ 2 µm<br />

Gauge block surface finish ≤ 0.2 µm<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

85


For vector network analyzer applications, <strong>Rosenberger</strong> offers<br />

high-flexible microwave test cables while maintaining excellent<br />

electrical characteristics. Outstanding phase and amplitude stability<br />

are guaranteed. A flexible armor protects the cable against mechanical<br />

damages.<br />

Für vektorielle Netzwerkanalysatoren bietet <strong>Rosenberger</strong><br />

<strong>Test</strong>kabel mit hoher Flexibiliät, die ausgezeichnete Werte<br />

für Phasen- und Amplitudenstabiltät bei Biegung erreichen.<br />

Eine flexible Spezialarmierung schützt die Kabel gegen<br />

Beschädigungen.<br />

<strong>Test</strong> cables are available as individual cable assemblies or cable<br />

sets containing 2 cables with 60 cm standard length each.<br />

The various types of <strong>Rosenberger</strong> test cables are optimized<br />

for frequencies up to 26.5 GHz, 40 GHz or 50 GHz. <strong>Test</strong> cable sets<br />

are supplied in stable wooden boxes.<br />

Die <strong>Test</strong>kabel werden einzeln oder als Set, bestehend aus 2<br />

Kabeln mit Standardlänge 60 cm, angeboten. Das Spektrum<br />

deckt Anwendungen bis 26,5 GHz, 40 GHz oder 50 GHz ab.<br />

Die Lieferung erfolgt in einer stabilen Holzschatulle.<br />

The <strong>Rosenberger</strong> interchangeable port connector system has<br />

been designed for test equipment applications using test ports<br />

that will be continually mated and re-mated. The interchangeable<br />

port connector system – designed with a panel mounting half and<br />

an especially developed sexless interface – allows a high number<br />

of mating cycles without any damage to the equipment device<br />

interface.<br />

Das <strong>Rosenberger</strong>-Wechselport-Steckersystem wurde für<br />

Messgeräte entwickelt, deren <strong>Test</strong>ports durch Serienmessungen<br />

sehr stark beansprucht werden. Das Wechselport-<br />

Steckersystem – mit einem Gehäuseeinbauteil und einem<br />

speziell entwickelten Innenleitersystem – gewährleistet wiederholte<br />

Steckungen ohne Verschleiß oder Beschädigung der<br />

Ausgangsstecker am Messgerät.


<strong>Test</strong> Cables &<br />

Interchangeable<br />

Port Connectors<br />

<strong>Test</strong> Cables & Interchangeable Port Connectors<br />

Features<br />

<strong>Test</strong> Cable Kits<br />

<strong>Test</strong> Cable Assemblies<br />

Interchangeable Port Connector System


<strong>Test</strong> Cables<br />

1<strong>Test</strong> Cables<br />

<strong>Test</strong> Cables<br />

<strong>Test</strong>kabel<br />

VA26 <strong>Test</strong> Cables<br />

with RPC-3.50 and/or RPC-SL connectors: for applications up to 26.5 GHz<br />

with RPC-N (50 Ω ) and/or RPC-7 connectors: for applications up to 18 GHz<br />

VA40 <strong>Test</strong> Cables<br />

with RPC-2.92 and/or RPC-SL connectors: for applications up to 40 GHz<br />

VA41 <strong>Test</strong> Cables<br />

with RPC-2.92, RPC-2.40 and/or RPC-SL connectors: for applications up to 40 GHz<br />

VA50 <strong>Test</strong> Cables<br />

with RPC-2.40 connectors: for applications up to 50 GHz<br />

VA75 <strong>Test</strong> Cables<br />

With RPC-N (75 Ω ) connectors: for applications up to 4 GHz<br />

<strong>Test</strong> Cables with Interchangeable Connector Heads<br />

<strong>Rosenberger</strong> offers a wide range of connector heads for test setups which often<br />

require other connector series, e.g. N, PC-7 or SMA connectors. Due to the special<br />

cable interface, mounting of changeable connector heads is very easy to handle,<br />

without any need for tools. Thus, test cables can be readily adapted to the required<br />

connector types already available on the DUT.<br />

VA 26-<strong>Test</strong>kabel<br />

Mit RPC-3.50- und/oder RPC-SL Steckverbindern: für Anwendungen bis 26.5 GHz<br />

Mit RPC-N (50 Ω )- und/oder RPC-7-Steckverbindern: für Anwendungen bis 18 GHz<br />

VA 40-<strong>Test</strong>kabel<br />

Mit RPC-2.92- und/oder RPC-SL-Steckverbindern: für Anwendungen bis 40 GHz<br />

VA 41-<strong>Test</strong>kabel<br />

Mit RPC-2.92-, RPC-2.40- und/oder RPC-SL-Steckverbindern: für Anwendungen bis<br />

40 GHz<br />

VA 50-<strong>Test</strong>kabel<br />

Mit RPC-2.40-Steckverbindern: für Anwendungen bis 50 GHz<br />

VA 75-<strong>Test</strong>kabel<br />

Mit RPC-N (75 Ω )-Steckverbindern: für Anwendungen bis 4 GHz<br />

<strong>Test</strong>kabel mit austauschbaren Wechselköpfen<br />

Für Messaufbauten mit anderen Steckverbinder-Serien, z.B. N, PC-7 oder SMA, bietet<br />

<strong>Rosenberger</strong> eine Vielzahl von Steckerköpfen. Das spezielle Kabel-Interface<br />

ermöglicht dem Anwender, Steckerköpfe ohne Werkzeug selbst zu wechseln und<br />

<strong>Test</strong>kabel auf die gewünschte Steckverbinder-Serie umzurüsten.<br />

Interchangeable Port Connector System<br />

Wechselport-Steckersystem<br />

The <strong>Rosenberger</strong> Interchangeable Port Connector System was developed for use<br />

with test equipment featuring a test port that will be continually mated and re-mated.<br />

In a heavy use environment the test port is readily damaged and this can entail in<br />

large repair expences. The <strong>Rosenberger</strong> Interchangeable Port Connector allows the<br />

equipment/device interface to be fully protected from damage.<br />

The Interchangeable Port Connector consists of a panel mounting half and a sexless<br />

interface. This interface uses two spring loaded butt contacts, which ensure that no<br />

wear occurs during mating and allows no possibility of damage due to mismatching<br />

of the connector halves.<br />

The interface between the panel mount and the adaptor is slotted. This ensures that<br />

at no time the mating faces will be allowed to rotate, thus preventing any damage.<br />

Adaptors can be interchanged and are available in different connector series.<br />

The connector heads for these two ranges are not compatible and can be used<br />

inside their own system only.<br />

Das <strong>Rosenberger</strong> Wechselport-Steckersystem wurde für Messgeräte entwickelt,<br />

deren <strong>Test</strong>ports durch Serienmessungen stark beansprucht werden und die an die<br />

verschiedenen Steckerfamilien, ohne Einsatz von Übergängen, in kurzer Zeit angepasst<br />

werden müssen. Durch den Einsatz des <strong>Rosenberger</strong> Wechselport-Steckersystems<br />

wird der Ausgangsstecker des Messgerätes sicher vor Beschädigung<br />

geschützt.<br />

Das Wechselport-Steckersystem besteht aus einem Gehäuseeinbauteil und einem<br />

speziell entwickelten Innenleitersystem, das eine Abnutzung der Innenleiterkontaktfläche<br />

verhindert. Die beiden federnden Innenleiter berühren sich nur auf ihren Kontaktflächen<br />

und gewährleisten so wiederholte Steckungen ohne Verschleiß.<br />

Durch die im Gehäuse-Verbindungsstück eingefräste Nut ist eine definierte Positionierung<br />

der verwendeten Adapter gewährleistet. Die Adapter können leicht gewechselt<br />

werden und sind für verschiedene Steckerfamilien lieferbar.<br />

Die Steckerköpfe sind nur innerhalb ihres Systems verwendbar und nicht untereinander<br />

austauschbar.<br />

88<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Cables<br />

Technical Data<br />

Technical Data <strong>Test</strong> Cables<br />

Cable Type VA26 VA26 VA40 / VA41 VA 50<br />

Length 60 cm 60 cm 60 cm 60 cm<br />

Max. frequency range 18 GHz 26.5 GHz 40 GHz 50 GHz<br />

Insertion loss < 1.3 dB @ DC to 18 GHz < 1.5 dB @ DC to 26.5 GHz < 2.0 dB @ DC to 40 GHz < 2.8 dB @ DC to 50 GHz<br />

Return loss<br />

Max. phase deviation 1<br />

(after 90° bending)<br />

28 dB @ DC to 4 GHz<br />

20 dB @ 4 GHz to 18 GHz<br />

< 0.5° @ DC to 4 GHz<br />

< 2.0° @ 4 GHz to 18 GHz<br />

26 dB @ DC to 4 GHz<br />

20 dB @ 4 GHz to 26.5 GHz<br />

< 1.0° @ DC to 4 GHz<br />

< 3.0° @ 4 GHz to 26.5 GHz<br />

26 dB @ DC to 4 GHz<br />

17 dB @ 4 GHz to 40 GHz<br />

< 1.3° @ DC to 4 GHz<br />

< 6.0° @ 4 GHz to 40 GHz<br />

26 dB @ DC to 4 GHz<br />

17 dB @ 4 GHz to 50 GHz<br />

< 1.3° @ DC to 4 GHz<br />

< 7.0° @ 4 GHz to 50 GHz<br />

<strong>Test</strong> Cables &<br />

Interchangeable<br />

Port Connectors<br />

max. phase deviation 1<br />

(straight after 3x90° bending)<br />

Amplitude stability 1<br />

Return loss stability 2<br />

< 0.5° @ DC to 4 GHz<br />

< 1.5° @ 4 GHz to 18 GHz<br />

< 0.03 dB @ DC to 4 GHz<br />

< 0.05 dB @ 4 GHz to 18 GHz<br />

> 48 dB @ DC to 4 GHz<br />

> 40 dB @ 4 GHz to 18 GHz<br />

< 0.5° @ DC to 4GHz<br />

< 1.5° @ 4 GHz to 26.5 GHz<br />

< 0.03 dB DC to 4 GHz<br />

< 0.05 dB @ 4 GHz to 26.5 GHz<br />

> 48 dB @ DC to 4 GHz<br />

> 40 dB @ 4 GHz to 26.5 GHz<br />

1. The test cable is terminated with a short circuit and tested on a calibrated vector<br />

network analyzer with a mandrel of 10 cm diameter. The one-way transmission<br />

phase stability is determined by dividing the two-way transmission phase measurement<br />

by two. The one-way transmission loss stability is determined by dividing the<br />

tow-way transmission loss measurement by two. The DATA/MEM feature provides<br />

an indication of both stabilities.<br />

< 1.0° @ DC to 4 GHz<br />

< 4.0° @ 4 GHz to 40 GHz<br />

< 0.03 dB @ DC to 4 GHz<br />

< 0.08 dB @ 4 GHz to 40 GHz<br />

> 45 dB @ DC to 4 GHz<br />

> 35 dB @ 4 GHz to 40 GHz<br />

< 1.0° @ DC to 4 GHz<br />

< 4.5° @ 4 GHz to 50 GHz<br />

< 0.03 dB @ DC to 4 GHz<br />

< 0.08 dB @ 4 GHz to 50 GHz<br />

> 45 dB @ DC to 4 GHz<br />

> 35 dB @ 4 GHz to 50 GHz<br />

1. Das <strong>Test</strong>kabel ist mit einem Kurzschluss abgeschlossen und wird an einem kalibrierten<br />

Netzwerkanalysator mit einem Biegedurchmesser von 10 cm getestet. Die<br />

Durchgangs-Phasenstabilität erhält man, indem man die Rückfluss-Phasenstabilität<br />

durch zwei teilt. Die Durchgangs-Amplitudenstabilität erhält man, indem man die<br />

Rückfluss-Amplitudenstabilität durch zwei teilt. Die DATA/MEM Funktion liefert eine<br />

Darstellung beider Stabilitäten.<br />

2. The test cable is terminated with a fixed load and tested on a calibrated vector network<br />

analyzer with a mandrel of 10 cm diameter. The DATA/MEM feature provides an<br />

indication of the return loss stability.<br />

2. Das <strong>Test</strong>kabel ist mit einem Festabschluss abgeschlossen und wird an einem kalibrierten<br />

Netzwerkanalysator mit einem Biegedurchmesser von 10 cm getestet. Die<br />

DATA/MEM Funktion liefert eine Darstellung der Rückfluss-Dämpfungsstabilität.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

89


<strong>Test</strong> Cables<br />

Designation<br />

Number Designation <strong>Test</strong> Cable Kits<br />

Nummernschlüssel <strong>Test</strong>kabel-Kits<br />

VA26- Nm- Nm- 60<br />

Length cm<br />

Connector 2<br />

Connector 1<br />

Vector Analyser<br />

<strong>Test</strong> Cable Kit<br />

(precise cable, connectors and armouring, please see data sheet)<br />

90<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Cables<br />

<strong>Test</strong> Cables<br />

<strong>Test</strong> Cables &<br />

Interchangeable<br />

Port Connectors<br />

<strong>Test</strong> Cable Kits<br />

xOrdering Number Return Loss Frequency Length Cable Cable<br />

Assemblies<br />

xVA26-3.50m-3.50f-60<br />

xVA26-Nm-Nm-60<br />

xVA26-PC7-PC7-60<br />

xVA26-TP-3.50-60<br />

xVA26-TP-N-60<br />

xVA26-TP-PC7-60<br />

xVA26-TP-W-60<br />

xVA40-TP-2.92-60<br />

xVA40-TP-W-60<br />

xVA41-TP-2.40-60<br />

xVA41-TP-2.92-60<br />

xVA41-TP-W-60<br />

xVA50-TP-2.40-60<br />

xVA75-Nm-Nm-60<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 26.5 GHz<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 26.5 GHz<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 26.5 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 50 GHz<br />

≥ 28 dB @ DC to 3 GHz<br />

≥ 23 dB @ 3 GHz to 4 GHz<br />

Connector 1 Connector 2<br />

DC to 26.5 GHz 600 mm RTK 162 2x LU7-055-600 RPC-3.50 male<br />

03 S 123-2U7S3<br />

DC to 18 GHz 600 mm RTK 162 2x LU7-042-600 RPC-N 50 Ω male<br />

05 S 123-2U7S3<br />

DC to 18 GHz 600 mm RTK 162 2x LU7-070-600 RPC-7<br />

07 P 123-2U7S3<br />

DC to 26.5 GHz 600 mm RTK 162 1x LU7-039-600<br />

1x LU7-043-600<br />

DC to 18 GHz 600 mm RTK 162 1x LU7-069-600<br />

1x LU7-059-600<br />

RPC-3.50<br />

ruggedized female<br />

03 KR 123-2U7S3<br />

RPC-3.50<br />

ruggedized female<br />

03 KR 123-2U7S3<br />

DC to 18 GHz 600 mm RTK 162 2x LU7-031-600 RPC-3.50<br />

ruggedized female<br />

03 KR 123-2U7S3<br />

DC to 26.5 GHz 600 mm RTK 162 2x LU7-035-600 RPC-3.50<br />

ruggedized female<br />

03 KR 123-2U7S3<br />

DC to 40 GHz 600 mm RTK 106 1x LU1-005-600<br />

1x LU1-006-600<br />

RPC-2.92<br />

ruggedized female<br />

02 KR 123-2U1S3<br />

DC to 40 GHz 600 mm RTK 106 2x LU1-022-600 RPC-2.92<br />

ruggedized female<br />

02 KR 123-2U1S3<br />

DC to 40 GHz 600 mm RTK 106 1x LU1-003-600<br />

1x LU1-025-600<br />

DC to 40 GHz 600 mm RTK 106 1x LU1-034-600<br />

1x LU1-045-600<br />

RPC-2.40<br />

ruggedized female<br />

09 KR 123-2U1S3<br />

RPC-2.40<br />

ruggedized female<br />

09 KR 123-2U1S3<br />

DC to 40 GHz 600 mm RTK 106 2x LU1-004-600 RPC-2.40<br />

ruggedized female<br />

09 KR 123-2U1S3<br />

DC to 50 GHz 600 mm RTK 125 1x LU8-005-600<br />

1x LU8-006-600<br />

RPC-2.40<br />

ruggedized female<br />

09 KR 123-2U8S3<br />

DC to 4 GHz 600 mm RG 216/U 2x L20-001-600 RPC-N 75 Ω<br />

male<br />

P5 S 123-320CS<br />

RPC-3.50 female<br />

03 K 123-2U7S3<br />

RPC-N 50 Ω male<br />

05 S 123-2U7S3<br />

RPC-7<br />

07 P 123-2U7S3<br />

RPC-3.50<br />

male and female<br />

03 S 123-2U7S3<br />

03 K 123-2U7S3<br />

RPC-N 50 Ω<br />

male and female<br />

05 S 123-2U7S3<br />

05 K 123-2U7S3<br />

RPC-7<br />

07 P 123-2U7S3<br />

RPC-SL 26.5 GHz<br />

female<br />

04 K 123-2U7S3<br />

RPC-2.92<br />

male and female<br />

02 S 123-2U1S3<br />

02 K 123-2U1S3<br />

RPC-SL 40 GHz<br />

female<br />

P4 K 123-2U1S3<br />

RPC-2.40<br />

male and female<br />

09 S 123-2U1S3<br />

09 K 123-2U1S3<br />

RPC-2.92<br />

male and female<br />

02 S 123-2U1S3<br />

02 K 123-2U1S3<br />

RPC-SL 40 GHz<br />

female<br />

P4 K 123-2U1S3<br />

RPC-2.40<br />

male and female<br />

09 S 123-2U8S3<br />

09 K 123-2U8S3<br />

RPC-N 75 Ω<br />

male<br />

P5 S 123-320CS<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

91


<strong>Test</strong> Cables<br />

Designation<br />

Number Designation <strong>Test</strong> Cable Assemblies<br />

Nummernschlüssel <strong>Test</strong>kabel-Assemblies<br />

L- U7- 031- 600<br />

Length cm<br />

Successive Number<br />

(precise connectors and armouring, please see data sheet)<br />

Cable group<br />

Leitung (<strong>Test</strong> Cable Assembly)<br />

92<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Cables<br />

<strong>Test</strong> Cables<br />

Connector 1 Connector 2<br />

Length<br />

<strong>Test</strong> Cables &<br />

Interchangeable<br />

Port Connectors<br />

<strong>Test</strong> Cable Assemblies<br />

xOrdering Number Return Loss Frequency Length Cable Connector 1 Connector 2 Armouring<br />

xL20-001-600<br />

xLU1-003-600<br />

xLU1-004-600<br />

xLU1-005-600<br />

xLU1-006-600<br />

xLU1-022-600<br />

xLU1-025-600<br />

xLU1-034-600<br />

xLU1-045-600<br />

xLU7-031-600<br />

xLU7-035-600<br />

xLU7-039-600<br />

xLU7-042-600<br />

xLU7-043-600<br />

xLU7-055-600<br />

xLU7-056-600<br />

xLU7-069-600<br />

xLU7-070-600<br />

xLU8-005-600<br />

xLU8-006-600<br />

≥ 28 dB @ DC to 3 GHz<br />

≥ 23 dB @ 3 GHz to 4 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 40 GHz<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 to 18 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 26.5 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 26.5 GHz<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 26.5 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 26.5 GHz<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 50 GHz<br />

≥ 26 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 50 GHz<br />

DC to 4 GHz 600 mm RG 216/U RPC-N 75 Ω male,<br />

P5 S 123-320CS<br />

DC to 40 GHz 600 mm RTK 106 RPC-2.40 female<br />

ruggedized,<br />

09 KR 123-2U1S3<br />

DC to 40 GHz 600 mm RTK 106 RPC-2.40 female<br />

ruggedized,<br />

09 KR 123-2U1S3<br />

DC to 40 GHz 600 mm RTK 106 RPC-2.92 female<br />

ruggedized,<br />

02 KR 123-2U1S3<br />

DC to 40 GHz 600 mm RTK 106 RPC-2.92 female<br />

ruggedized,<br />

02 KR 123-2U1S3<br />

DC to 40 GHz 600 mm RTK 106 RPC-2.92 female<br />

ruggedized,<br />

02 KR 123-2U1S3<br />

DC to 40 GHz 600 mm RTK 106 RPC-2.40 female<br />

ruggedized,<br />

09 KR 123-2U1S3<br />

DC to 40 GHz 600 mm RTK 106 RPC-2.40 female<br />

ruggedized,<br />

09 KR 123-2U1S3<br />

DC to 40 GHz 600 mm RTK 106 RPC-2.40 female<br />

ruggedized,<br />

09 KR 123-2U1S3<br />

DC to 18 GHz 600 mm RTK 162 RPC-3.50 female<br />

ruggedized,<br />

03 KR 123-2U7S3<br />

DC to 26.5 GHz 600 mm RTK 162 RPC-3.50 female ruggedized,<br />

03 KR 123-2U7S3<br />

DC to 26.5 GHz 600 mm RTK 162 RPC-3.50 male,<br />

03 S 123-2U7S3<br />

DC to 18 GHz 600 mm RTK 162 RPC-N 50 Ω male,<br />

05 S 123-2U7S3<br />

DC to 26.5 GHz 600 mm RTK 162 RPC-3.50 female,<br />

03 K 123-2U7S3<br />

DC to 26.5 GHz 600 mm RTK 162 RPC-3.50 male,<br />

03 S 123-2U7S3<br />

DC to 18 GHz 600 mm RTK 162 RPC-3.50 female<br />

ruggedized,<br />

03 KR 123-2U7S3<br />

DC to 18 GHz 600 mm RTK 162 RPC-3.50 female<br />

ruggedized,<br />

03 KR 123-2U7S3<br />

DC to 18 GHz 600 mm RTK 162 RPC-7,<br />

07 P 123-2U7S3<br />

DC to 50 GHz 600 mm RTK 125 RPC-2.40 male,<br />

09 S 123-2U8S3<br />

DC to 50 GHz 600 mm RTK 125 RPC-2.40 female,<br />

09 K 123-2U8S3<br />

RPC-N 75 Ω male,<br />

P5 S 123-320CS<br />

RPC-2.40 male,<br />

09 S 123-2U1S3<br />

RPC-SL 40 GHz<br />

female,<br />

P4 K 123-2U1S3<br />

RPC-2.92 male,<br />

02 S 123-2U1S3<br />

RPC-2.92 female,<br />

02 K 123-2U1S3<br />

RPC-SL 40 GHz<br />

female,<br />

P4 K 123-2U1S3<br />

RPC-2.40 female,<br />

09 K 123-2U1S3<br />

RPC-2.92 male,<br />

02 S 123-2U1S3<br />

RPC-2.92 female,<br />

02 K 123-2U1S3<br />

RPC-7,<br />

07 P 123-2U7S3<br />

RPC-SL 26.5 GHz<br />

female,<br />

04 K 123-2U7S3<br />

RPC-3.50 female<br />

ruggedized,<br />

03 KR 123-2U7S3<br />

RPC-N 50 Ω male,<br />

05 S 123-2U7S3<br />

RPC-3.50 female<br />

ruggedized,<br />

03 KR 123-2U7S3<br />

RPC-3.50 female,<br />

03 K 123-2U7S3<br />

RPC-N 50 Ω female,<br />

05 K 123-2U7S3<br />

RPC-N 50 Ω male,<br />

05 S 123-2U7S3<br />

RPC-7,<br />

07 P 123-2U7S3<br />

RPC-2.40 female<br />

ruggedized,<br />

09 KR 123-2U8S3<br />

RPC-2.40 female<br />

ruggedized,<br />

09 KR 123-2U8S3<br />

Protection braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

ETFE Tubing with protection<br />

braid<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

93


Interchangeable Port Connector System<br />

2Interchangeable Port Connector System<br />

Technical Data RPC-SL 26.5 GHz<br />

Applicable standards | Anwendbare Standards<br />

Interface according to | Interface gemäß<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (mated pair) | Rückflußdämpfung (gestecktes Paar)<br />

Insertion loss (mated pair) | Dämpfung (gestecktes Paar)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

Interchangeable port connector system<br />

50 Ω<br />

DC to 26.5 GHz<br />

≥ 21 dB, DC to 26.5 GHz<br />

≤ 0.03 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 3.0 mΩ<br />

≤ 2.0 mΩ<br />

1000 V rms<br />

335 V rms<br />

≥ 100 dB up to 1 GHz<br />

Mating cycles | Steckzyklen ≥ 3000<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 27 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

2.0 Nm<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen<br />

MIL-STD 202, Method 107, Condition B<br />

Corrosion resistance | Korrosionsbeständigkeit<br />

MIL-STD 202, Method 101, Condition B<br />

Vibration | Vibration<br />

MIL-STD 202, Method 204, Condition D<br />

Shock | Schock<br />

MIL-STD 202, Method 213, Condition I<br />

Moisture resistance | Feuchtigkeitsbeständigkeit MIL-STD 202, Method 106<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Stainless steel, gold-plated<br />

PS<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

94<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Interchangeable Port Connector System<br />

Products<br />

Adaptor and Cable Clamp RPC-SL 26.5 GHz<br />

xOrdering Number Version Remarks Return Loss Cable<br />

Group<br />

x04 K 529-K00 S3 straight RPC-SL 26.5 GHz<br />

female - female,<br />

panel mount,<br />

round flange<br />

x03 Z 001-272 D straight RPC-3.50<br />

cable clamp for<br />

04K529-K00S3,<br />

UT 141<br />

Assembly Panel Piercing<br />

Instruction / PCB Layout<br />

≥ 21 dB @ DC to 26.5 GHz MB 82 1<br />

0<br />

0<br />

72 03 A 1<br />

ø17<br />

21<br />

12.6<br />

SW13<br />

<strong>Test</strong> Cables &<br />

Interchangeable<br />

Port Connectors<br />

SW8<br />

Adaptor RPC-SL 26.5 GHz<br />

xOrdering Number Version Remarks Return Loss<br />

x05 S 104-S00 S3 straight RPC-N 50 Ω male - RPC-SL 26.5 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz<br />

33<br />

SW20<br />

SW18<br />

x05 K 104-S00 S3 straight RPC-N 50 Ω female - RPC-SL 26.5 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz<br />

31.8<br />

SW14<br />

SW18<br />

x07 P 104-S00 S3 straight RPC-7 - RPC-SL 26.5 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz 1<br />

41.6<br />

SW19<br />

SW14<br />

SW18<br />

x03 S 104-S00 S3 straight RPC-3.50 male - RPC-SL 26.5 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

29.2<br />

ø 18.5<br />

SW18<br />

x03 K 104-S00 S3 straight RPC-3.50 female - RPC-SL 26.5 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

28<br />

ø 19<br />

SW14<br />

SW18<br />

Torque Wrench<br />

xOrdering Number<br />

x04 W 021-000<br />

Remarks<br />

flat 18 mm - 2 Nm torque for RPC-SL 26.5 GHz, RPC-SL 40 GHz<br />

157<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

95


Interchangeable Port Connector System<br />

Technology<br />

Technical Data RPC-SL 40 GHz<br />

Applicable standards | Anwendbare Standards<br />

Interface according to | Interface gemäß<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (mated pair) | Rückflußdämpfung (gestecktes Paar)<br />

Insertion loss (mated pair) | Dämpfung (gestecktes Paar)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

Interchangeable port connector system<br />

50 Ω<br />

DC to 40 GHz<br />

≥ 19 dB, DC to 40 GHz<br />

≤ 0.04 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 3.0 mΩ<br />

≤ 2.0 mΩ<br />

750 V rms<br />

250 V rms<br />

≥ 100 dB up to 1 GHz<br />

Mating cycles | Steckzyklen ≥ 3000<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 22 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

2.0 Nm<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen<br />

MIL-STD 202, Method 107, Condition B<br />

Corrosion resistance | Korrosionsbeständigkeit<br />

MIL-STD 202, Method 101, Condition B<br />

Vibration | Vibration<br />

MIL-STD 202, Method 204, Condition D<br />

Shock | Schock<br />

MIL-STD 202, Method 213, Condition I<br />

Moisture resistance | Feuchtigkeitsbeständigkeit MIL-STD 202, Method 106<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Stainless steel, gold-plated<br />

PS<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

96<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Interchangeable Port Connector System<br />

Products<br />

Adaptor and Cable Clamp RPC-SL 40 GHz<br />

xOrdering Number Version Remarks Return Loss Cable<br />

Group<br />

Assembly Panel Piercing<br />

Instruction / PCB Layout<br />

xP4 K 52A-K00 S3 straight RPC-SL 40 GHz<br />

female - female,<br />

panel mount,<br />

round flange<br />

≥ 21 dB @ DC to 26.5 GHz<br />

≥ 16 dB @ 26.5 to 40 GHz<br />

MB 82 1<br />

0<br />

0<br />

21<br />

ø17<br />

SW13<br />

<strong>Test</strong> Cables &<br />

Interchangeable<br />

Port Connectors<br />

x02 Z 001-2W9 D straight RPC-2.92<br />

cable clamp for<br />

P4K52A-K00S3,<br />

UT 118<br />

W9 03 A 1<br />

0<br />

0<br />

12.6<br />

SW8<br />

Adaptor RPC-SL 40 GHz<br />

xOrdering Number Version Remarks Return Loss<br />

x05 S 1P4-S00 S3 straight RPC-N 50 Ω male - RPC-SL 40 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz<br />

33<br />

SW20<br />

SW18<br />

x05 K 1P4-S00 S3 straight RPC-N 50 Ω female - RPC-SL 40 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz<br />

31.8<br />

SW14<br />

SW18<br />

x07 P 1P4-S00 S3 straight RPC-7 - RPC-SL 40 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz 1<br />

41.6<br />

SW19<br />

SW14<br />

SW18<br />

x02 S 1P4-S00 S3 straight RPC-2.92 male - RPC-SL 40 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

≥ 19 dB @ 26.5 to 40 GHz<br />

1<br />

29.1<br />

ø 19<br />

SW8<br />

SW14<br />

SW18<br />

x02 K 1P4-S00 S3 straight RPC-2.92 female - RPC-SL 40 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

≥ 19 dB @ 26.5 to 40 GHz<br />

1<br />

0<br />

0<br />

28<br />

ø 19<br />

SW14<br />

SW18<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

97


Interchangeable Port Connector System<br />

xOrdering Number Version Remarks Return Loss<br />

x09 S 1P4-S00 S3 straight RPC-2.40 male - RPC-SL 40 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

≥ 19 dB @ 26.5 GHz to 40 GHz<br />

28.4<br />

SW18<br />

x09 K 1P4-S00 S3 straight RPC-2.40 female - RPC-SL 40 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

≥ 19 dB @ 26.5 GHz to 40 GHz<br />

29.1<br />

SW18<br />

Torque Wrench<br />

xOrdering Number<br />

x04 W 021-000<br />

Remarks<br />

flat 18 mm - 2 Nm torque for RPC-SL 26.5 GHz, RPC-SL 40 GHz<br />

157<br />

98<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Interchangeable Port Connector System<br />

<strong>Test</strong> Cables &<br />

Interchangeable<br />

Port Connectors<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

99


<strong>Rosenberger</strong> offers a wide range of test devices for microwave<br />

measurements designed for various requirements – from<br />

low-frequency devices for simple measurements to components<br />

which permit high-precision broadband measurements:<br />

opens, shorts and loads, sliding loads, T-calibration adaptors,<br />

mismatches, airlines, attenuators, matching attenuators and<br />

test accessories, e. g. gauges or tools.<br />

Für verschiedene Aufgaben in der Mikrowellenmesstechnik<br />

bietet <strong>Rosenberger</strong> eine Vielzahl von <strong>Test</strong>-Komponenten<br />

an – von Bauelementen mit relativ niedrigen Frequenzen für<br />

einfache Messaufgaben bis hin zu Bauteilen, die in komplexen<br />

Messaufbauten auch für anspruchsvolle und hochpräzise Messungen<br />

geeignet sind: Opens, Shorts und Loads, Gleitlasten,<br />

T-Kalibrieradapter, Fehlabschlüsse, Luftleitungen, Dämpfungsglieder,<br />

Anpassungsglieder und Zubehör-Komponenten wie<br />

Werkzeuge oder Messuhren.<br />

Additional devices are available on request.<br />

Weitere Komponenten sind auf Anfrage erhältlich.


<strong>Test</strong> Devices<br />

<strong>Test</strong> Devices<br />

Features<br />

Open-Short-Load<br />

Sliding Loads<br />

T-<strong>Calibration</strong> Adaptors<br />

Mismatches<br />

Airlines<br />

Attenuators<br />

Matching Attenuators<br />

Gauges, Tools


<strong>Test</strong> Devices<br />

1<strong>Test</strong> Open Devices - Short - Load<br />

Open - Short - Load<br />

RPC-N 50 Ω Open - Short - Load<br />

xOrdering Number Version Remarks Return Loss Power<br />

Handling<br />

x05 S 12L-000 S3 straight RPC-N 50 Ω open circuit, male,<br />

a = 46.3 mm<br />

x05 S 12S-000 S3 straight RPC-N 50 Ω short circuit, male,<br />

a = 46.3 mm<br />

x05 S 150-C10 S3 straight RPC-N 50 Ω<br />

broadband load, calibration kit, male,<br />

a = 42.7 mm<br />

x05 S 150-010 S3 straight RPC-N 50 Ω<br />

broadband load standard, male,<br />

a = 49.3 mm<br />

x05 K 12L-000 S3 straight RPC-N 50 Ω open circuit, female,<br />

a = 46.3 mm<br />

x05 K 12S-000 S3 straight RPC-N 50 Ω short circuit, female,<br />

a = 46.3 mm<br />

x05 K 150-C10 S3 straight RPC-N 50 Ω<br />

broadband load, calibration kit, female,<br />

a = 39.2 mm<br />

x05 K 150-010 S3 straight RPC-N 50 Ω<br />

broadband load standard, female,<br />

a = 48 mm<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 GHz to 18 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.15 dB @ 4 GHz to 18 GHz<br />

≥ 45 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 18 GHz<br />

≥ 28 dB @ DC to 18 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 GHz to 18 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.15 dB @ 4 GHz to 18 GHz<br />

≥ 45 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 18 GHz<br />

≥ 28 dB @ DC to 18 GHz<br />

0.5 W<br />

0.5 W<br />

0.5 W<br />

0.5 W<br />

SW20<br />

a<br />

a<br />

complete calibration kits also available<br />

RPC-N 75 Ω Open - Short - Load<br />

xOrdering Number Version Remarks Return Loss Power<br />

Handling<br />

xP5 S 12L-000 S3 straight RPC-N 75 Ω open circuit, male,<br />

a = 46.3 mm<br />

xP5 S 12S-000 S3 straight RPC-N 75 Ω short circuit, male,<br />

a = 46.3 mm<br />

xP5 S 150-C10 S3 straight RPC-N 75 Ω<br />

broadband load,<br />

calibration kit, male<br />

a = 42.7 mm<br />

≤ 0.07 dB @ DC to 2 GHz<br />

≤ 0.10 dB @ 2 GHz to 4 GHz<br />

≤ 0.07 dB @ DC to 2 GHz<br />

≤ 0.10 dB @ 2 GHz to 4 GHz<br />

≥ 40 dB @ DC to 2 GHz<br />

≥ 36 dB @ 2 GHz to 4 GHz<br />

0.5 W<br />

SW20<br />

a<br />

xP5 K 12L-000 S3 straight RPC-N 75 Ω open circuit, female,<br />

a = 46.3 mm<br />

xP5 K 12S-000 S3 straight RPC-N 75 Ω short circuit, female,<br />

a = 46.3 mm<br />

xP5 K 150-C10 S3 straight RPC-N 75 Ω<br />

broadband load<br />

calibration kit, female,<br />

a = 41.3 mm<br />

≤ 0.07 dB @ DC to 2 GHz<br />

≤ 0.10 dB @ 2 GHz to 4 GHz<br />

≤ 0.07 dB @ DC to 2 GHz<br />

≤ 0.10 dB @ 2 GHz to 4 GHz<br />

≥ 40 dB @ DC to 2 GHz<br />

≥ 36 dB @ 2 GHz to 4 GHz<br />

0.5 W<br />

a<br />

complete calibration kits also available<br />

102<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

RPC-TNC Open - Short - Load<br />

xOrdering Number Remarks Return Loss Power<br />

Handling<br />

x06 S 12L-000 S3<br />

x06 S 12S-000 S3<br />

x06 S 150-C10 S3<br />

RPC-TNC open circuit, male<br />

a = 48.8 mm<br />

RPC-TNC short circuit, male<br />

a = 49.8 mm<br />

RPC-TNC broadband load,<br />

calibration kit, male<br />

a = 50.3 mm<br />

≤ 0.50 dB @ DC to 4 GHz<br />

≤ 1.00 dB @ 4 GHz to 18 GHz<br />

≤ 0.50 dB @ DC to 4 GHz<br />

≤ 1.00 dB @ 4 GHz to 18 GHz<br />

≥ 35 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 18 GHz<br />

0.5 W<br />

SW15<br />

SW14<br />

a<br />

ø15.7<br />

x06 K 12L-000 S3<br />

x06 K 12S-000 S3<br />

x06 K 150-C10 S3<br />

RPC-TNC open circuit, female<br />

a = 59 mm<br />

RPC-TNC short circuit, female<br />

a = 58.6 mm<br />

RPC-TNC broadband load,<br />

calibration kit, female<br />

a = 51.4 mm<br />

≤ 0.50 dB @ DC to 4 GHz<br />

≤ 1.00 dB @ 4 GHz to 18 GHz<br />

≤ 0.50 dB @ DC to 4 GHz<br />

≤ 1.00 dB @ 4 GHz to 18 GHz<br />

≥ 35 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 18 GHz<br />

0.5 W<br />

SW14<br />

a<br />

ø15.7<br />

<strong>Test</strong> Devices<br />

complete calibration kits also available<br />

RPC-7 Open - Short - Load<br />

xOrdering Number Remarks Return Loss Power<br />

Handling<br />

x07 P 12L-000 S3<br />

x07 P 12S-000 S3<br />

x07 P 150-C10 S3<br />

x07 P 150-010 S3<br />

RPC-7 open circuit,<br />

a = 42.9 mm<br />

RPC-7 short circuit,<br />

a = 44.2 mm<br />

RPC-7 broadband load,<br />

calibration kit,<br />

a = 42.9 mm<br />

RPC-7<br />

broadband load standard,<br />

a = 42.9 mm<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.15 dB @ 4 GHz to 18 GHz<br />

≤ 0.07 dB @ DC to 4 GHz<br />

≤ 0.12 dB @ 4 GHz to 18 GHz<br />

≥ 45 dB @ DC to 4 GHz<br />

≥ 32 dB @ 4 GHz to 18 GHz<br />

≥ 28 dB @ DC to 18 GHz<br />

0.5 W<br />

0.5 W<br />

ø 22<br />

SW19<br />

a<br />

complete calibration kits also available<br />

RPC-SP Open - Short - Load<br />

xOrdering Number Remarks Return Loss Power<br />

Handling<br />

x10 S 12L-000 S3<br />

x10 S 12S-000 S3<br />

x10 S 150-C10 S3<br />

RPC-SP open circuit, male<br />

a = 34.4 mm<br />

RPS-SP short circuit, male<br />

a = 35.6 mm<br />

RPC-SP broadband load, male<br />

a = 31.4 mm<br />

≤ 0.15 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 GHz to 22 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.15 dB @ 4 GHz to 22 GHz<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 18 GHz<br />

≥ 23 dB @ 18 GHz to 22 GHz<br />

0.5 W<br />

SW12<br />

a<br />

ø 9<br />

x10 K 12L-000 S3<br />

x10 K 12S-000 S3<br />

x10 K 150-C10 S3<br />

RPC-SP open circuit, female<br />

a = 38.8 mm<br />

RPS-SP short circuit, female<br />

a = 40.2 mm<br />

RPC-SP broadband load, female<br />

a = 34.4 mm<br />

≤ 0.15 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 GHz to 22 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.15 dB @ 4 GHz to 22 GHz<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 18 GHz<br />

≥ 23 dB @ 18 GHz to 22 GHz<br />

0.5 W<br />

SW12<br />

a<br />

ø 9<br />

complete calibration kits also available<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

103


<strong>Test</strong> Devices<br />

RPC-3.50 Open - Short - Load<br />

xOrdering Number Remarks Return Loss Power<br />

Handling<br />

x03 S 12L-000 S3<br />

x03 S 12S-000 S3<br />

x03 S 12S-001 D3<br />

x03 S 150-C10 S3<br />

x03 S 17R-001 D3<br />

RPC-3.50 open circuit, male,<br />

a = 30.9 mm<br />

RPC-3.50 short circuit, male,<br />

a = 30.7 mm<br />

RPC-3.50 short circuit, male,<br />

LRL calibration kit<br />

a = 28.9 mm<br />

RPC-3.50 broadband load,<br />

calibration kit, male,<br />

a = 31.5 mm<br />

RPC-3.50<br />

broadband load standard,<br />

male<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 GHz to 26.5 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.15 dB @ 4 GHz to 26.5 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.15 dB @ 4 GHz to 26.5 GHz<br />

≥ 40 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 26.5 GHz<br />

≥ 36 dB @ DC to 4 GHz,<br />

≥ 23 dB @ 4 GHz to 26.5 GHz<br />

0.5 W<br />

0.5 W<br />

SW8<br />

a<br />

18.6<br />

ø 9<br />

SW8<br />

SW9<br />

x03 K 12L-000 S3<br />

x03 K 12S-000 S3<br />

x03 K 12S-001 D3<br />

x03 K 150-C10 S3<br />

x03 K 17R-001 D3<br />

RPC-3.50 open circuit, female,<br />

a = 29.9 mm<br />

RPC-3.50 short circuit, female,<br />

a = 29.9 mm<br />

RPC-3.50 short circuit, female,<br />

LRL calibration kit<br />

a = 28.8 mm<br />

RPC-3.50 broadband load,<br />

calibration kit, female,<br />

a = 30.5 mm<br />

RPC-3.50<br />

broadband load standard,<br />

female<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 GHz to 26.5 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.15 dB @ 4 GHz to 26.5 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.15 dB @ 4 GHz to 26.5 GHz<br />

≥ 40 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 26.5 GHz<br />

≥ 36 dB @ DC to 4 GHz,<br />

≥ 23 dB @ 4 GHz to 26.5 GHz<br />

0.5 W<br />

0.5 W<br />

SW9<br />

a<br />

18.6<br />

ø 9<br />

SW9<br />

complete calibration kits also available<br />

RPC-2.92 Open - Short - Load<br />

xOrdering Number Remarks Return Loss Power<br />

Handling<br />

x02 S 12L-000 S3<br />

x02 S 12S-000 S3<br />

x02S 12S-001 D3<br />

x02 S 150-C10 S3<br />

x02 S 17R-001 D3<br />

RPC-2.92 open circuit, male,<br />

a = 30.9 mm<br />

RPC-2.92 short circuit, male,<br />

a = 30.9 mm<br />

RPC-3.50 short circuit, male,<br />

LRL calibration kit<br />

a = 28.9 mm<br />

RPC-2.92 broadband load, male,<br />

a = 31 mm<br />

RPC-2.92<br />

broadband load standard,<br />

male<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 to 40 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 to 40 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 GHz to 40 GHz<br />

≥ 42 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 to 40 GHz<br />

≥ 36 dB @ DC to 4 GHz,<br />

≥ 21 dB @ 4 GHz to 40 GHz<br />

0.5 W<br />

0.5 W<br />

SW8<br />

SW9<br />

a<br />

14.5<br />

ø 10<br />

ø 9<br />

SW8<br />

SW9<br />

x02 K 12L-000 S3<br />

x02 K 12S-000 S3<br />

x02K 12S-001 D3<br />

x02 K 150-C10 S3<br />

x02 K 17R-001 D3<br />

RPC-2.92 open circuit, female,<br />

a = 29.9 mm<br />

RPC-2.92 short circuit, female,<br />

a = 29.9 mm<br />

RPC-3.50 short circuit, female,<br />

LRL calibration kit<br />

a = 28.8 mm<br />

RPC-2.92 broadband load,<br />

calibration kit, female,<br />

a = 29.9 mm<br />

RPC-2.92<br />

broadband load standard,<br />

female<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 GHz to 40 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 GHz to 40 GHz<br />

≤ 0.10 dB @ DC to 4 GHz<br />

≤ 0.20 dB @ 4 GHz to 40 GHz<br />

≥ 42 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 40 GHz<br />

≥ 36 dB @ DC to 4 GHz,<br />

≥ 21 dB @ 4 GHz to 40 GHz<br />

0.5 W<br />

0.5 W<br />

SW9<br />

a<br />

13.5<br />

ø 9<br />

ø 10<br />

SW9<br />

complete calibration kits also available<br />

104<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

RPC-2.40 Open - Short - Load<br />

xOrdering Number Remarks Return Loss Power<br />

Handling<br />

x09 S 12L-000 S3<br />

x09 S 12S-000 S3<br />

x09 S 150-C10 S3<br />

x09 K 12L-000 S3<br />

x09 K 12S-000 S3<br />

x09 K 150-C10 S3<br />

RPC-2.40 open circuit, male,<br />

a = 30.3 mm<br />

RPC-2.40 short circuit, male,<br />

a = 31.4 mm<br />

RPC-2.40 broadband load,<br />

calibration kit, male,<br />

a = 26.5 mm<br />

RPC-2.40 open circuit, female,<br />

a = 30 mm<br />

RPC-2.40 short circuit, female,<br />

a = 32.1 mm<br />

RPC-2.40 broadband load,<br />

calibration kit, female,<br />

a = 27.3 mm<br />

≤ 0.15 dB @ DC to 4 GHz<br />

≤ 0.30 dB @ 4 GHz to 50 GHz<br />

≤ 0.15 dB @ DC to 4 GHz<br />

≤ 0.25 dB @ 4 GHz to 50 GHz<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 20 GHz<br />

≥ 26 dB @ 20 GHz to 26.5 GHz<br />

≥ 22 dB @ 26.5 GHz to 50 GHz<br />

≤ 0.15 dB @ DC to 4 GHz<br />

≤ 0.30 dB @ 4 GHz to 50 GHz<br />

≤ 0.15 dB @ DC to 4 GHz<br />

≤ 0.25 dB @ 4 GHz to 50 GHz<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 20 GHz<br />

≥ 26 dB @ 20 GHz to 26.5 GHz<br />

≥ 22 dB @ 26.5 GHz to 50 GHz<br />

0.5 W<br />

0.5 W<br />

SW8<br />

SW9<br />

SW9<br />

a<br />

a<br />

ø 9<br />

ø 9<br />

<strong>Test</strong> Devices<br />

complete calibration kits also available<br />

RPC-1.85 Open - Short - Load<br />

xOrdering Number Remarks Return Loss Power<br />

Handling<br />

x08 S 12L-000 S3<br />

x08 S 12S-000 S3<br />

x08 S 150-C10 S3<br />

x08 K 12L-000 S3<br />

x08 K 12S-000 S3<br />

x08 K 150-C10 S3<br />

RPC-1.85 open circuit, male,<br />

a = 30.3 mm<br />

RPC-1.85 short circuit, male,<br />

a = 32 mm<br />

RPC-1.85 broadband load,<br />

calibration kit, male,<br />

a = 26.5 mm<br />

RPC-1.85 open circuit, female,<br />

a = 30 mm<br />

RPC-1.85 short circuit, female,<br />

a = 32.7 mm<br />

RPC-1.85 broadband load,<br />

calibration kit, female,<br />

a = 27.3 mm<br />

≤ 0.15 dB @ DC to 4 GHz<br />

≤ 0.40 dB @ 4 GHz to 65 GHz<br />

≤ 0.15 dB @ DC to 4 GHz<br />

≤ 0.30 dB @ 4 GHz to 65 GHz<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 26.5 GHz<br />

≥ 22 dB @ 26.5 GHz to 50 GHz<br />

≥ 20 dB @ 50 GHz to 65 GHz<br />

≤ 0.15 dB @ DC to 4 GHz<br />

≤ 0.40 dB @ 4 GHz to 65 GHz<br />

≤ 0.15 dB @ DC to 4 GHz<br />

≤ 0.30 dB @ 4 GHz to 65 GHz<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 26.5 GHz<br />

≥ 22 dB @ 26.5 GHz to 50 GHz<br />

≥ 20 dB @ 50 GHz to 65 GHz<br />

0.5 W<br />

0.5 W<br />

SW8<br />

SW9<br />

SW9<br />

a<br />

a<br />

ø 9<br />

ø 9<br />

complete calibration kits also available<br />

RPC-1.00 Short - Load<br />

xOrdering Number Remarks Return Loss Power<br />

Handling<br />

x01 S 12S-000 D3 RPC-1.00 short circuit, male ≤ 0.20 dB @ DC to 20 GHz<br />

≤ 0.50 dB @ 20 GHz to 50 GHz<br />

≤ 0.75 dB @ 50 GHz to 75 GHz<br />

≤ 1.00 dB @ 75 GHz to 110 GHz<br />

x01 S 150-C10 D3<br />

x01 K 12S-000 D3<br />

x01 K 150-C10 D3<br />

RPC-1.00 lowband load,<br />

calibration kit, male<br />

RPC-1.00 short circuit, female,<br />

a = 20.5 mm<br />

RPC-1.00 lowband load,<br />

calibration kit, female,<br />

a = 23 mm<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 18 GHz<br />

≥ 28 dB @ 18 GHz to 22 GHz<br />

≤ 0.20 dB @ DC to 20 GHz<br />

≤ 0.50 dB @ 20 GHz to 50 GHz<br />

≤ 0.75 dB @ 50 GHz to 75 GHz<br />

≤ 1.00 dB @ 75 GHz to 110 GHz<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 18 GHz<br />

≥ 28 dB @ 18 GHz to 22 GHz<br />

0.5 W<br />

0.5 W<br />

SW6<br />

22.8<br />

a<br />

ø 9<br />

ø 9<br />

complete calibration kits also available<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

105


<strong>Test</strong> Devices<br />

Sliding Load<br />

Sliding Loads<br />

RPC-N 50 Ω Sliding Load<br />

xOrdering Number Remarks Return Loss<br />

x05 S 150-G300 RPC-N 50 Ω male ≥ 35 dB @ 2 GHz to 18 GHz<br />

max. 416<br />

x05 K 150-G300 RPC-N 50 Ω female ≥ 35 dB @ 2 GHz to 18 GHz<br />

max. 424<br />

RPC-TNC Sliding Load<br />

xOrdering Number Remarks Return Loss<br />

x06 S 150-G300 RPC-TNC ≥ 30 dB @ 2 GHz to 18 GHz<br />

max. 416<br />

x06 K 150-G300 RPC-TNC ≥ 30 dB @ 2 GHz to 18 GHz<br />

max. 418<br />

RPC-7 Sliding Load<br />

xOrdering Number Remarks Return Loss<br />

x07 P 150-G300 RPC-7 ≥ 35 dB @ 2 GHz to 18 GHz<br />

max. 416<br />

RPC-3.50 Sliding Load<br />

xOrdering Number Remarks Return Loss<br />

x03 S 150-G300 RPC-3.50 male ≥ 26 dB @ 2 to 4 GHz<br />

≥ 32 dB @ 4 to 26.5 GHz<br />

max. 218<br />

x03 K 150-G300 RPC-3.50 female ≥ 26 dB @ 2 to 4 GHz<br />

≥ 32 dB @ 4 to 26.5 GHz<br />

max. 219<br />

RPC-2.92 Sliding Load<br />

xOrdering Number Remarks Return Loss<br />

x02 S 150-G300 RPC-2.92 male ≥ 28 dB @ 4 GHz to 8 GHz<br />

≥ 32 dB @ 8 GHz to 40 GHz<br />

max. 221<br />

x02 K 150-G300 RPC-2.92 female ≥ 28 dB @ 4 GHz to 8 GHz<br />

≥ 32 dB @ 8 GHz to 40 GHz<br />

max. 220<br />

106<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

RPC-2.40 Sliding Load<br />

xOrdering Number Remarks Return Loss<br />

x09 S 150-G300 RPC-2.40 male ≥ 26.4 dB @ 4 GHz to 8 GHz<br />

≥ 32 dB @ 8 GHz to 50 GHz<br />

max. 218<br />

x09 K 150-G300 RPC-2.40 female ≥ 26.4 dB @ 4 GHz to 8 GHz<br />

≥ 32 dB @ 8 GHz to 50 GHz<br />

max. 219<br />

RPC-1.85 Sliding Load<br />

xOrdering Number Remarks Return Loss<br />

x08 S 150-G300 RPC-1.85 male ≥ 26.4 dB @ 4 GHz to 8 GHz<br />

≥ 32 dB @ 8 GHz to 65 GHz<br />

max. 218<br />

<strong>Test</strong> Devices<br />

x08 K 150-G300 RPC-1.85 female ≥ 26.4 dB @ 4 GHz to 8 GHz<br />

≥ 32 dB @ 8 GHz to 65 GHz<br />

max. 219<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

107


<strong>Test</strong> Devices<br />

T- <strong>Calibration</strong>- Adaptors<br />

T-<strong>Calibration</strong>-Adaptors<br />

7-16 Open - Short - Load<br />

xOrdering Number Version Remarks Return Loss<br />

x60 S 34R-MSO N3 T-Adaptor 7-16 male-male-male<br />

Resulting phase uncertainty:<br />

Open ≤ 3.0° to 4 GHz,<br />

Short ≤ 2.0° to 4 GHz<br />

x60 S 36R-MSO N3 T-Adaptor 7-16 male-male-male<br />

Resulting phase uncertainty:<br />

Open ≤ 3.0° to 6 GHz,<br />

Short ≤ 3.0° to 6 GHz<br />

Open/Short:<br />

≤ 0.15 dB @ DC to 4 GHz<br />

Load:<br />

≥ 40 dB @ DC to 2.5 GHz<br />

≥ 38 dB @ 2.5 GHz to 4 GHz<br />

Open/Short:<br />

≤ 0.15 dB @ DC to 6 GHz<br />

Load:<br />

≥ 40 dB @ DC to 2.5 GHz<br />

≥ 38 dB @ 2.5 GHz to 6 GHz<br />

short<br />

82.5<br />

SW32<br />

SW32<br />

SW32<br />

load<br />

open<br />

reduced scale<br />

55<br />

x60 K 34R-MSO N3 T-Adaptor 7-16 female-female-female<br />

Resulting phase uncertainty:<br />

Open ≤ 3.0° to 4 GHz,<br />

Short ≤ 2.0° to 4 GHz<br />

x60 K 36R-MSO N3 T-Adaptor 7-16 female-female-female<br />

Resulting phase uncertainty:<br />

Open ≤ 3.0° to 6 GHz,<br />

Short ≤ 3.0° to 6 GHz<br />

Open/Short:<br />

≤ 0.15 dB @ DC to 4 GHz<br />

Load:<br />

≥ 40 dB @ DC to 2.5 GHz<br />

≥ 38 dB @ 2.5 GHz to 4 GHz<br />

Open/Short:<br />

≤ 0.15 dB @ DC to 6 GHz<br />

Load:<br />

≥ 40 dB @ DC to 2.5 GHz<br />

≥ 38 dB @ 2.5 GHz to 6 GHz<br />

load<br />

short<br />

85<br />

reduced scale<br />

53<br />

open<br />

N Standard 50 Ω Open - Short - Load<br />

xOrdering Number Version Remarks Return Loss<br />

x53 S 34R-MSO N3 T-Adaptor N Standard 50 Ω male-male-male<br />

Resulting phase uncertainty:<br />

Open ≤ 3.0° to 4 GHz,<br />

Short ≤ 2.0° to 4 GHz<br />

x53 S 36R-MSO N3 T-Adaptor N Standard 50 Ω male-male-male<br />

Resulting phase uncertainty:<br />

Open ≤ 3.0° to 6 GHz,<br />

Short ≤ 2.0° to 6 GHz<br />

Open/Short:<br />

≤ 0.1 dB @ DC to 4 GHz<br />

Load:<br />

≥ 42 dB @ DC to 2.5 GHz<br />

≥ 38 dB @ 2.5 GHz to 4 GHz<br />

Open/Short:<br />

≤ 0.1 dB @ DC to 6 GHz<br />

Load:<br />

≥ 42 dB @ DC to 2.5 GHz<br />

≥ 38 dB @ 2.5 GHz to 6 GHz<br />

load<br />

ø 21<br />

short<br />

72<br />

ø 21<br />

SW18<br />

ø 21<br />

open<br />

SW18<br />

reduced scale<br />

SW18<br />

x53 K 34R-MSO N3 T-Adaptor N Standard 50 Ω female-female-female<br />

Resulting phase uncertainty:<br />

Open ≤ 3.0° to 4 GHz,<br />

Short ≤ 2.0° to 4 GHz<br />

x53 K 36R-MSO N3 T-Adaptor N Standard 50 Ω female-female-female<br />

Resulting phase uncertainty:<br />

Open ≤ 3.0° to 6 GHz,<br />

Short ≤ 2.0° to 6 GHz<br />

Open/Short:<br />

≤ 0.1 dB @ DC to 4 GHz<br />

Load:<br />

≥ 42 dB @ DC to 2.5 GHz<br />

≥ 38 dB @ 2.5 GHz to 4 GHz<br />

Open/Short:<br />

≤ 0.1 dB @ DC to 6 GHz<br />

Load:<br />

≥ 42 dB @ DC to 2.5 GHz<br />

≥ 38 dB @ 2.5 GHz to 6 GHz<br />

load<br />

short<br />

70<br />

ø15.7<br />

ø15.7<br />

open<br />

reduced scale<br />

108<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

Mismatches<br />

Mismatches<br />

RPC-N 50 Ω Mismatches<br />

xOrdering Number Remarks VSWR Power Handling<br />

x05 S 150-055 S3<br />

x05 S 150-060 S3<br />

x05 S 150-075 S3<br />

RPC-N 50 Ω male,<br />

Impedance 55 Ω<br />

RPC-N 50 Ω male,<br />

Impedance 60 Ω<br />

RPC-N 50 Ω male,<br />

Impedance 75 Ω<br />

1.1 ± 0.04 @ DC to 12.4 GHz,<br />

1.1 ± 0.06 @ 12.4 GHz to 18 GHz<br />

1.2 ± 0.04 @ DC to 8 GHz<br />

1.2 ± 0.05 @ 8 GHz to 12.4 GHz<br />

1.2 ± 0.07 @ 12.4 GHz to 18 GHz<br />

1.5 ± 0.05 @ DC to 8 GHz<br />

1.5 ± 0.07 @ 8 GHz to 12.4 GHz<br />

1.5 ± 0.09 @ 12.4 GHz to 18 GHz<br />

1 W<br />

1 W<br />

1 W<br />

SW20<br />

42.7<br />

x05 K 150-055 S3<br />

x05 K 150-060 S3<br />

x05 K 150-075 S3<br />

RPC-N 50 Ω female,<br />

Impedance 55 Ω<br />

RPC-N 50 Ω female,<br />

Impedance 60 Ω<br />

RPC-N 50 Ω female,<br />

Impedance 75 Ω<br />

1.1 ± 0.04 @ DC to 12.4 GHz,<br />

1.1 ± 0.06 @ 12.4 GHz to 18 GHz<br />

1.2 ± 0.04 @ DC to 8 GHz<br />

1.2 ± 0.05 @ 8 GHz to 12.4 GHz<br />

1.2 ± 0.07 @ 12.4 GHz to 18 GHz<br />

1.5 ± 0.05 @ DC to 8 GHz<br />

1.5 ± 0.07 @ 8 GHz to 12.4 GHz<br />

1.5 ± 0.09 @ 12.4 GHz to 18 GHz<br />

1 W<br />

1 W<br />

1 W<br />

39.2<br />

<strong>Test</strong> Devices<br />

RPC-3.50 Mismatches<br />

xOrdering Number Remarks VSWR Power Handling<br />

x03 S 150-055 S3<br />

x03 S 150-060 S3<br />

x03 S 150-075 S3<br />

x03 K 150-055 S3<br />

x03 K 150-060 S3<br />

x03 K 150-075 S3<br />

RPC-3.50 male,<br />

Impedance 55 Ω<br />

RPC-3.50 male,<br />

Impedance 60 Ω<br />

RPC-3.50 male,<br />

Impedance 75 Ω<br />

RPC-3.50 female,<br />

Impedance 55 Ω<br />

RPC-3.50 female,<br />

Impedance 60 Ω<br />

RPC-3.50 female,<br />

Impedance 75 Ω<br />

1.1 ± 0.03 @ DC to 12 GHz<br />

1.1 ± 0.05 @ 12 GHz to 26.5 GHz<br />

1.2 ± 0.03 @ DC to 12 GHz<br />

1.2 ± 0.05 @ 12 GHz to 26.5 GHz<br />

1.5 ± 0.06 @ DC to 12 GHz<br />

1.5 ± 0.10 @ 12 GHz to 26.5 GHz<br />

1.1 ± 0.03 @ DC to 12 GHz<br />

1.1 ± 0.05 @ 12 GHz to 26.5 GHz<br />

1.2 ± 0.03 @ DC to 12 GHz<br />

1.2 ± 0.05 @ 12 GHz to 26.5 GHz<br />

1.5 ± 0.06 @ DC to 12 GHz<br />

1.5 ± 0.10 @ 12 GHz to 26.5 GHz<br />

0.5 W @ 25 °C<br />

0.5 W @ 25 °C<br />

0.5 W @ 25 °C<br />

0.5 W @ 25 °C<br />

0.5 W @ 25 °C<br />

0.5 W @ 25 °C<br />

SW8<br />

SW9<br />

SW9<br />

31.5<br />

30.5<br />

ø 9<br />

ø 9<br />

RPC-2.92 Mismatches<br />

xOrdering Number Remarks VSWR Power Handling<br />

x02 S 150-055 S3<br />

x02 S 150-060 S3<br />

x02 S 150-075 S3<br />

RPC-2.92 male,<br />

Impedance 55 Ω<br />

RPC-2.92 male,<br />

Impedance 60 Ω<br />

RPC-2.92 male,<br />

Impedance 75 Ω<br />

1.1 ±0.05 @ DC to 40 GHz 0.5 W @ 25 °C<br />

1.2 ±0.05 @ DC to 40 GHz 0.5 W @ 25 °C<br />

1.5 ±0.05 @ DC to 20 GHz<br />

1.5 ±0.08 @ 20 GHz to 40 GHz<br />

0.5 W @ 25 °C<br />

SW8<br />

SW9<br />

31<br />

ø 9<br />

x02 K 150-055 S3<br />

x02 K 150-060 S3<br />

x02 K 150-075 S3<br />

RPC-2.92 female,<br />

Impdeance 55 Ω<br />

RPC-2.92 female,<br />

Impedance 60 Ω<br />

RPC-2.92 female,<br />

Impedance 75 Ω<br />

1.1 ±0.05 @ DC to 40 GHz 0.5 W @ 25 °C<br />

1.2 ±0.05 @ DC to 40 GHz 0.5 W @ 25 °C<br />

1.5 ±0.05 @ DC to 20 GHz<br />

1.5 ±0.08 @ 20 GHz to 40 GHz<br />

0.5 W @ 25 °C<br />

SW9<br />

30<br />

ø 9<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

109


<strong>Test</strong> Devices<br />

Airlines<br />

Airlines<br />

RPC-N 50 Ω Airlines<br />

xOrdering Number Remarks Return Loss Frequency<br />

x05 S 101-K026 50 Ω ;<br />

a = 36.8 mm, b = 26.4 mm<br />

x05 S 101-K033 50 Ω ;<br />

a = 43.7 mm, b = 33.3 mm<br />

x05 S 101-K061 50 Ω ;<br />

a = 71.8 mm, b = 61 mm<br />

x05 S 101-K100 50 Ω ;<br />

a = 110.8 mm, b = 100 mm<br />

x05 S 102-K100<br />

50 Ω with 25 Ω section;<br />

a = 110,8 mm, b = 100 mm<br />

≥ 40 dB @ 0.3 GHz to 4 GHz<br />

≥ 35 dB @ 4 GHz to 18 GHz<br />

≥ 40 dB @ 0.3 GHz to 4 GHz<br />

≥ 35 dB @ 4 GHz to 18 GHz<br />

≥ 40 dB @ 0.3 GHz to 4 GHz<br />

≥ 35 dB @ 4 GHz to 18 GHz<br />

≥ 40 dB @ 0.3 GHz to 4 GHz<br />

≥ 35 dB @ 4 GHz to 18 GHz<br />

0.3 GHz to 18 GHz<br />

0.3 GHz to 18 GHz<br />

0.3 GHz to 18 GHz<br />

0.3 GHz to 18 GHz<br />

0.3 GHz to 18 GHz<br />

SW20<br />

b<br />

SW14<br />

a<br />

ø15.7<br />

RPC-N 75 Ω Airlines<br />

xOrdering Number Remarks Return Loss Frequency<br />

xP5 S 101-K031 75 Ω ;<br />

a = 41.6 mm, b = 31.2 mm<br />

xP5 S 101-K150 50 Ω ;<br />

a = 160.8 mm, b = 150 mm<br />

≥ 42 dB @ 0.1 GHz to 2 GHz<br />

≥ 40 dB @ 2 GHz to 4 GHz<br />

≥ 42 dB @ 0.1 GHz to 2 GHz<br />

≥ 40 dB @ 2 GHz to 4 GHz<br />

0.1 GHz to 4 GHz<br />

0.1 GHz to 4 GHz<br />

b<br />

a<br />

ø15.7<br />

SW20<br />

SW14<br />

RPC-7 Airlines<br />

xOrdering Number Remarks Return Loss Frequency<br />

x07 P 101-P034 50 Ω ; a = 40 mm, b = 34 mm ≥ 45 dB @ 0.3 GHz to 4 GHz<br />

≥ 40 dB @ 4 GHz to 18 GHz<br />

x07 P 101-P041 50 Ω ; a = 47 mm, b = 41 mm ≥ 45 dB @ 0.3 GHz to 4 GHz<br />

≥ 40 dB @ 4 GHz to 18 GHz<br />

x07 P 101-P068 50 Ω ; a = 74 mm, b = 68 mm ≥ 45 dB @ 0.3 GHz to 4 GHz<br />

≥ 40 dB @ 4 GHz to 18 GHz<br />

x07 P 101-P100 50 Ω ;<br />

a = 106.4 mm, b = 100 mm<br />

x07 P 102-P100<br />

50 Ω with 25 Ω section,<br />

a = 106.4 mm, b = 100 mm<br />

≥ 45 dB @ 0.3 GHz to 4 GHz<br />

≥ 40 dB @ 4 GHz to 18 GHz<br />

0.3 GHz to 18 GHz<br />

0.3 GHz to 18 GHz<br />

0.3 GHz to 18 GHz<br />

0.3 GHz to 18 GHz<br />

0.3 GHz to 18 GHz<br />

a<br />

b<br />

RPC-SP Airlines<br />

xOrdering Number Remarks Return Loss Frequency<br />

x10 S 101-K005 50 Ω ,<br />

a = 10.2 mm, b = 5.6 mm<br />

≥ 36 dB @ 0.2 GHz to 4 GHz<br />

≥ 32 dB @ 4 GHz to 22 GHz<br />

0.2 GHz to 22 GHz<br />

a<br />

ø7.3<br />

b<br />

x10 S 101-K027 50 Ω ,<br />

a = 33 mm, b = 27.7 mm<br />

≥ 36 dB @ 0.2 GHz to 4 GHz<br />

≥ 32 dB @ 4 GHz to 22 GHz<br />

0.2 GHz to 22 GHz<br />

a<br />

ø 22<br />

b<br />

110<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

RPC-3.50 Airlines<br />

xOrdering Number Remarks Return Loss Frequency<br />

x03 S 101-K015 50 Ω ;<br />

a = 19.9 mm, b = 15 mm<br />

x03 S 101-K020 50 Ω ;<br />

a = 24.9 mm, b = 20 mm<br />

x03 S 101-K038 50 Ω ;<br />

a = 43.6 mm, b = 38.5 mm<br />

x03 S 101-K100 50 Ω ;<br />

a = 105.1 mm, b = 100 mm<br />

x03 S 102-K100<br />

50 Ω with 25 Ω section;<br />

a = 105.1 mm, b = 100 mm<br />

≥ 40 dB @ 0.3 GHz to 4 GHz<br />

≥ 35 dB @ 4 GHz to 26.5 GHz<br />

≥ 40 dB @ 0.3 GHz to 4 GHz<br />

≥ 35 dB @ 4 GHz to 26.5 GHz<br />

≥ 40 dB @ 0.3 GHz to 4 GHz<br />

≥ 35 dB @ 4 GHz to 26.5 GHz<br />

≥ 40 dB @ 0.3 GHz to 4 GHz<br />

≥ 35 dB @ 4 GHz to 26.5 GHz<br />

0.3 GHz to 26.5 GHz<br />

0.3 GHz to 26.5 GHz<br />

0.3 GHz to 26.5 GHz<br />

0.3 GHz to 26.5 GHz<br />

0.3 GHz to 26.5 GHz<br />

a<br />

b<br />

RPC-2.92 Airlines<br />

xOrdering Number Remarks Return Loss Frequency<br />

x02 S 101-K015 50 Ω ;<br />

a = 19.9 mm, b = 15 mm<br />

x02 S 101-K018 50 Ω ;<br />

a = 23.2 mm, b = 18.3 mm<br />

x02 S 101-K040 50 Ω ;<br />

a = 45.1 mm, b = 40 mm<br />

x02 S 101-K075 50 Ω ;<br />

a = 80 mm, b = 75 mm<br />

x02 S 102-K075 50 Ω with 25 Ω section ;<br />

a = 80 mm, b = 75 mm<br />

≥ 38 dB @ 0.3 GHz to 4 GHz<br />

≥ 30 dB @ 4 GHz to 40 GHz<br />

≥ 38 dB @ 0.3 GHz to 4 GHz<br />

≥ 30 dB @ 4 GHz to 40 GHz<br />

≥ 38 dB @ 0.3 GHz to 4 GHz<br />

≥ 30 dB @ 4 GHz to 40 GHz<br />

≥ 38 dB @ 0.3 GHz to 4 GHz<br />

≥ 30 dB @ 4 GHz to 40 GHz<br />

0.3 GHz to 40 GHz<br />

0.3 GHz to 40 GHz<br />

0.3 GHz to 40 GHz<br />

0.3 GHz to 40 GHz<br />

0.3 GHz to 40 GHz<br />

a<br />

b<br />

<strong>Test</strong> Devices<br />

RPC-2.40 Airlines<br />

xOrdering Number Remarks Return Loss Frequency<br />

x09 S 101-K013 50 Ω ;<br />

a = 18.4 mm, b = 13 mm<br />

x09 S 101-K015 50 Ω ;<br />

a = 20.9 mm, b = 15.5 mm<br />

x09 S 101-K025 50 Ω ;<br />

a = 30.9 mm, b = 25.5 mm<br />

≥ 36 dB @ 0.4 GHz to 4 GHz<br />

≥ 26 dB @ 4 GHz to 50 GHz<br />

≥ 36 dB @ 0.4 GHz to 4 GHz<br />

≥ 26 dB @ 4 GHz to 50 GHz<br />

≥ 36 dB @ 0.4 GHz to 4 GHz<br />

≥ 26 dB @ 4 GHz to 50 GHz<br />

0.4 GHz to 50 GHz<br />

0.4 GHz to 50 GHz<br />

0.4 GHz to 50 GHz<br />

a<br />

b<br />

RPC-1.85 Airlines<br />

xOrdering Number Remarks Return Loss Frequency<br />

x08 S 101-K013 50 Ω ;<br />

a = 18.4 mm, b = 13 mm<br />

x08 S 101-K014 50 Ω ;<br />

a = 20.3 mm, b = 14.9 mm<br />

x08 S 101-K022 50 Ω ;<br />

a = 28 mm, b = 22.6 mm<br />

≥ 34 dB @ 0.5 GHz to 4 GHz<br />

≥ 24 dB @ 4 GHz to 65 GHz<br />

≥ 34 dB @ 0.5 GHz to 4 GHz<br />

≥ 24 dB @ 4 GHz to 65 GHz<br />

≥ 34 dB @ 0.5 GHz to 4 GHz<br />

≥ 24 dB @ 4 GHz to 65 GHz<br />

0.5 GHz to 65 GHz<br />

0.5 GHz to 65 GHz<br />

0.5 GHz to 65 GHz<br />

a<br />

b<br />

RPC-1.00 Airlines<br />

xOrdering Number Remarks Return Loss Frequency<br />

x01 S 101-K011 50 Ω ;<br />

a = 14.1 mm, b = 11 mm<br />

x01 S 101-K012 50 Ω ;<br />

a = 15.2 mm, b = 12.14 mm<br />

x01 S 101-K016 50 Ω ;<br />

a = 19.7 mm, b = 16.68 mm<br />

≥ 24 dB @ 0.8 GHz to 20 GHz<br />

≥ 20 dB @ 20 GHz to 50 GHz<br />

≥ 18 dB @ 50 GHz to 75 GHz<br />

≥ 14 dB @ 75 GHz to 110 GHz<br />

≥ 24 dB @ 0.8 GHz to 20 GHz<br />

≥ 20 dB @ 20 GHz to 50 GHz<br />

≥ 18 dB @ 50 GHz to 75 GHz<br />

≥ 14 dB @ 75 GHz to 110 GHz<br />

≥ 24 dB @ 0.8 GHz to 20 GHz<br />

≥ 20 dB @ 20 GHz to 50 GHz<br />

≥ 18 dB @ 50 GHz to 75 GHz<br />

≥ 14 dB @ 75 GHz to 110 GHz<br />

0.8 GHz to 110 GHz<br />

0.8 GHz to 110 GHz<br />

0.8 GHz to 110 GHz<br />

a<br />

b<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

111


<strong>Test</strong> Devices<br />

Attenuators<br />

Attenuators<br />

RPC-N 50 Ω , male - female<br />

xOrdering<br />

Number<br />

x05 AS 102-K03 S3 a = 49.1 mm<br />

x05 AS 102-K06 S3 a = 49.1 mm<br />

x05 AS 102-K10 S3 a = 49.1 mm<br />

x05 AS 102-K20 S3 a = 49.1 mm<br />

x05 AS 102-K30 S3 a = 49.1 mm<br />

x05 AS 102-K40 S3 a = 57 mm<br />

x05 AS 122-K20 S3 a = 49.1 mm<br />

x05 AS 122-K40 S3 a = 57 mm<br />

Remarks Return Loss Attenuation Tolerance Power<br />

Handling<br />

≥ 26.4 dB @ DC to 4 GHz<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 18 GHz<br />

≥ 26.4 dB @ DC to 4 GHz<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 18 GHz<br />

≥ 26.4 dB @ DC to 4 GHz<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 18 GHz<br />

≥ 26.4 dB @ DC to 4 GHz<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 18 GHz<br />

≥ 26.4 dB @ DC to 4 GHz<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 18 GHz<br />

≥ 26.4 dB @ DC to 4 GHz<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 18 GHz<br />

≥ 32 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 18 GHz<br />

≥ 32 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 18 GHz<br />

3 dB ±0.3 dB @ 8 GHz<br />

±0.5 dB @ 12.4 GHz<br />

±0.8 dB @ 18 GHz<br />

6 dB ±0.3 dB @ 8 GHz<br />

±0.5 dB @ 12.4 GHz<br />

±0.8 dB @ 18 GHz<br />

10 dB ±0.3 dB @ 8 GHz<br />

±0.6 dB @ 12.4 GHz<br />

±0.8 dB @ 18 GHz<br />

20 dB ±0.3 dB @ 4 GHz<br />

±0.5 dB @ 8 GHz<br />

±0.8 dB @ 18 GHz<br />

30 dB ±0.8 dB @ 4 GHz<br />

±1.0 dB @ 12.4 GHz<br />

±1.5 dB @ 18 GHz<br />

40 dB ±0.8 dB @ 4 GHz<br />

±1.0 dB @ 12.4 GHz<br />

±1.5 dB @ 18 GHz<br />

20 dB ±0.3 dB @ 4 GHz<br />

±0.5 dB @ 18 GHz<br />

40 dB ±0.5 dB @ 4 GHz<br />

±1.0 dB @ 18 GHz<br />

2 W @ 25 °C<br />

2 W @ 25 °C<br />

2 W @ 25 °C<br />

2 W @ 25 °C<br />

2 W @ 25 °C<br />

2 W @ 25 °C<br />

0.5 W<br />

0.5 W<br />

a<br />

RPC-7<br />

xOrdering<br />

Number<br />

x07 AP 122-P20 S3<br />

x07 AP 122-P40 S3<br />

Return Loss Attenuation Tolerance Power<br />

Handling<br />

≥ 32 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 18 GHz<br />

≥ 32 dB @ DC to 4 GHz<br />

≥ 23 dB @ 4 GHz to 18 GHz<br />

20 dB ±0.3 dB @ 4 GHz<br />

± 0.5 dB @ 18 GHz<br />

40 dB ±0.5 dB @ 4 GHz<br />

± 1.0 dB @ 18 GHz<br />

0.5 W<br />

0.5 W<br />

41.5<br />

ø 22<br />

SW19<br />

SW19<br />

RPC-3.50, male - female<br />

xOrdering<br />

Number<br />

Remarks Return Loss Attenuation Tolerance Power<br />

Handling<br />

x03 AS 102-K03 S3 a = 30.1 mm ≥ 26.4 dB @ DC to 4 GHz 3 dB ±0.5 dB @ 26.5 GHz 2 W @ 25 °C<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 26.5 GHz<br />

x03 AS 102-K06 S3 a = 30.1 mm ≥ 26.4 dB @ DC to 4 GHz 6 dB ±0.5 dB @ 26.5 GHz 2 W @ 25 °C<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 26.5 GHz<br />

x03 AS 102-K10 S3 a = 30.1 mm ≥ 26.4 dB @ DC to 4 GHz 10 dB ±0.5 dB @ 26.5 GHz 2 W @ 25 °C<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 26.5 GHz<br />

x03 AS 102-K20 S3 a = 30.1 mm ≥ 26.4 dB @ DC to 4 GHz 20 dB ±0.5 dB @ 26.5 GHz 2 W @ 25 °C<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 26.5 GHz<br />

x03 AS 102-K30 S3 a = 30.1 mm ≥ 26.4 dB @ DC to 4 GHz 30 dB ±0.7 dB @ 26.5 GHz 2 W @ 25 °C<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 26.5 GHz<br />

x03 AS 102-K40 S3 a = 32.1 mm ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 23.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 19.1 dB @ 12.4 GHz to 26.5 GHz<br />

40 dB ±1.0 dB @ 26.5 GHz 2 W @ 25 °C<br />

a<br />

x03 AS 122-K20 S3 a = 30.1 mm ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 20.1 dB @ 4 GHz to 26.5 GHz<br />

x03 AS 122-K40 S3 a = 32.1 mm ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 20.1 dB @ 4 GHz to 26.5 GHz<br />

20 dB ±0.3 dB @ 4 GHz<br />

±0.5 dB @ 26.5 GHz<br />

40 dB ±0.4 dB @ 4 GHz<br />

±1.0 dB @ 26.5 GHz<br />

0.5 W<br />

0.5 W<br />

SW8<br />

SW9<br />

ø 10<br />

112<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

RPC-2.92, male - female<br />

xOrdering<br />

Number<br />

Remarks Return Loss Attenuation Tolerance Power<br />

Handling<br />

x02 AS 102-K03 S3 a = 24.8 mm ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 40 GHz<br />

x02 AS 102-K06 S3 a = 24.8 mm ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 40 GHz<br />

x02 AS 102-K10 S3 a = 24.8 mm ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 40 GHz<br />

x02 AS 102-K20 S3 a = 24.8 mm ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 40 GHz<br />

x02 AS 102-K40 S3 a = 25.8 mm ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 40 GHz<br />

x02 AS 122-K20 S3 a = 24.8 mm ≥ 32 dB @ DC to 4 GHz<br />

≥ 20.1 dB @ 4 GHz to 40 GHz<br />

x02 AS 122-K40 S3 a = 28.8 mm ≥ 32 dB @ DC to 4 GHz<br />

≥ 20.1 dB @ 4 GHz to 40 GHz<br />

3 dB ±0.3 dB @ 4 GHz<br />

±0.5 dB @ 40 GHz<br />

0.5 W<br />

6 dB ±0.3 dB @ 4 GHz 0.5 W<br />

±0.5 dB @ 40 GHz<br />

10 dB ±0.3 dB @ 4 GHz 0.5 W<br />

±0.5 dB @ 40 GHz<br />

20 dB ±0.3 dB @ 4 GHz 0.5 W<br />

±0.5 dB @ 40 GHz<br />

40 dB ±0.4 dB @ 4 GHz 0.5 W<br />

±1.0 dB @ 40 GHz<br />

20 dB ±0.3 dB @ 40 GHz 0.5 W<br />

40 dB ±0.4 dB @ 4 GHz<br />

±0.8 dB @ 40 GHz<br />

0.5 W<br />

SW8<br />

a<br />

SW9<br />

<strong>Test</strong> Devices<br />

RPC-1.85, male - female<br />

xOrdering<br />

Number<br />

Remarks Return Loss Attenuation Tolerance Power<br />

Handling<br />

x08 AS 102-K03 S3 a = 23.3 mm ≥ 32 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 26.5 GHz<br />

≥ 20 dB @ 26.5 GHz to 40 GHz<br />

≥ 14 dB @ 40 GHz to 65 GHz<br />

x08 AS 102-K06 S3 a = 23.3 mm ≥ 32 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 26.5 GHz<br />

≥ 20 dB @ 26.5 GHz to 40 GHz<br />

≥ 15 dB @ 40 GHz to 65 GHz<br />

x08 AS 102-K10 S3 a = 23.3 mm ≥ 32 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 26.5 GHz<br />

≥ 20 dB @ 26.5 GHz to 40 GHz<br />

≥ 15 dB @ 40 GHz to 65 GHz<br />

x08 AS 102-K20 S3 a = 23.3 mm ≥ 32 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 26.5 GHz<br />

≥ 20 dB @ 26.5 GHz to 40 GHz<br />

≥ 15 dB @ 40 GHz to 65 GHz<br />

x08 AS 102-K40 S3 a = 24.3 mm ≥ 32 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 26.5 GHz<br />

≥ 20 dB @ 26.5 GHz to 40 GHz<br />

≥ 15 dB @ 40 GHz to 65 GHz<br />

3 dB ±0.5 dB @ 40 GHz<br />

±1.0 dB @ 65 GHz<br />

6 dB ±0.5 dB @ 40 GHz<br />

±1.0 dB @ 65 GHz<br />

10 dB ±0.5 dB @ 40 GHz<br />

±1.0 dB @ 65 GHz<br />

20 dB ±0.5 dB @ 40 GHz<br />

±1.0 dB @ 65 GHz<br />

40 dB ±0.5 dB @ 40 GHz<br />

±1.0 dB @ 65 GHz<br />

0.5 W @ 25 °C<br />

0.5 W @ 25 °C<br />

0.5 W @ 25 °C<br />

0.5 W @ 25 °C<br />

0.5 W @ 25 °C<br />

SW8<br />

SW9<br />

a<br />

ø 10<br />

SMP, male-female<br />

xOrdering<br />

Number<br />

Return Loss Attenuation Tolerance Power<br />

Handling<br />

x19 AS 101-K03 E3<br />

x19 AS 101-K06 E3<br />

x19 AS 101-K10 E3<br />

x19 AS 101-K20 E3<br />

x19 AS 101-K30 E3<br />

≥ 20.8 dB @ DC to 4 GHz<br />

≥ 16.5 dB @ 4 GHz to 12.4 GHz<br />

≥ 14.0 dB @ 12.4 GHz to 18 GHz<br />

≥ 20.8 dB @ DC to 4 GHz<br />

≥ 16.5 dB @ 4 GHz to 12.4 GHz<br />

≥ 14.0 dB @ 12.4 GHz to 18 GHz<br />

≥ 20.8 dB @ DC to 4 GHz<br />

≥ 16.5 dB @ 4 GHz to 12.4 GHz<br />

≥ 14.0 dB @ 12.4 GHz to 18 GHz<br />

≥ 20.8 dB @ DC to 4 GHz<br />

≥ 16.5 dB @ 4 GHz to 12.4 GHz<br />

≥ 14.0 dB @ 12.4 GHz to 18 GHz<br />

≥ 20.8 dB @ DC to 4 GHz<br />

≥ 16.5 dB @ 4 GHz to 12.4 GHz<br />

≥ 14.0 dB @ 12.4 GHz to 18 GHz<br />

3 dB ±0.3 dB 0.5 W @ 25 °C<br />

6 dB ±0.3 dB 0.5 W @ 25 °C<br />

10 dB ±0.3 dB 0.5 W @ 25 °C<br />

20 dB ±0.3 dB 0.5 W @ 25 °C<br />

30 dB ±0.3 dB 0.5 W @ 25 °C<br />

ø6.35<br />

22.3<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

113


<strong>Test</strong> Devices<br />

QMA, male-female<br />

xOrdering<br />

Number<br />

Return Loss Attenuation Tolerance Power<br />

Handling<br />

x28 AS 102-K03 N3 ≥ 26.5 dB @ DC to 2 GHz<br />

≥ 20.8 dB @ 2 GHz to 6 GHz<br />

x28 AS 102-K06 N3 ≥ 26.5 dB @ DC to 2 GHz<br />

≥ 20.8 dB @ 2 GHz to 6 GHz<br />

x28 AS 102-K10 N3 ≥ 26.5 dB @ DC to 2 GHz<br />

≥ 20.8 dB @ 2 GHz to 6 GHz<br />

x28 AS 102-K20 N3 ≥ 26.5 dB @ DC to 2 GHz<br />

≥ 20.8 dB @ 2 GHz to 6 GHz<br />

x28 AS 102-K30 N3 ≥ 26.5 dB @ DC to 2 GHz<br />

≥ 20.8 dB @ 2 GHz to 6 GHz<br />

3 dB ±0.3 dB @ 6 GHz 2 W @ 25 °C<br />

29<br />

6 dB ±0.3 dB @ 6 GHz 2 W @ 25 °C<br />

10 dB ±0.3 dB @ 6 GHz 2 W @ 25 °C<br />

20 dB ±0.3 dB @ 6 GHz 2 W @ 25 °C<br />

30 dB ±0.3 dB @ 6 GHz 2 W @ 25 °C<br />

SMA, male-female<br />

xOrdering Remarks Return Loss Attenuation Tolerance Power<br />

Number<br />

Handling<br />

x32 AS 102-K03 S3 a = 20 mm<br />

x32 AS 102-K06 S3 a = 20 mm<br />

x32 AS 102-K10 S3 a = 20 mm<br />

x32 AS 102-K20 S3 a = 20 mm<br />

x32 AS 102-K30 S3 a = 20 mm<br />

x32 AS 102-K40 S3 a = 22 mm<br />

≥ 23.1 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 16.5 dB @ 12.4 GHz to 18 GHz<br />

≥ 23.1 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 16.5 dB @ 12.4 GHz to 18 GHz<br />

≥ 23.1 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 16.5 dB @ 12.4 GHz to 18 GHz<br />

≥ 23.1 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 16.5 dB @ 12.4 GHz to 18 GHz<br />

≥ 23.1 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 16.5 dB @ 12.4 GHz to 18 GHz<br />

≥ 23.1 dB @ DC to 4 GHz<br />

≥ 19.1 dB @ 4 GHz to 12.4 GHz<br />

≥ 16.5 dB @ 12.4 GHz to 18 GHz<br />

3 dB ±0.3 dB @ 8 GHz<br />

±0.5 dB @ 12.4 GHz<br />

±0.75 dB @ 18 GHz<br />

6 dB ±0.3 dB @ 8 GHz<br />

±0.5 dB @ 12.4 GHz<br />

±0.75 dB @ 18 GHz<br />

10 dB ±0.3 dB @ 8 GHz<br />

±0.5 dB @ 12.4 GHz<br />

±0.75 dB @ 18 GHz<br />

20 dB ±0.3 dB @ 8 GHz<br />

±0.5 dB @ 12.4 GHz<br />

±0.75 dB @ 18 GHz<br />

30 dB ±0.3 dB @ 4 GHz<br />

±0.5 dB @ 8 GHz<br />

±0.75 dB @ 12.4 GHz<br />

±1.5 dB @ 18 GHz<br />

40 dB ±0.3 dB @ 4 GHz<br />

±0.5 dB @ 8 GHz<br />

±1.0 dB @ 12.4 GHz<br />

±1.75 dB @ 18 GHz<br />

2 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

2 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

2 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

2 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

2 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

2 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

SW7<br />

SW8<br />

a<br />

ø 8<br />

114<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

N 50 Ω Standard, male-female<br />

xOrdering<br />

Number<br />

Return Loss Attenuation Tolerance Power<br />

Handling<br />

x53 AS 102-K01 N3 ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 20.8 dB @ 4 GHz to 10 GHz<br />

≥ 19.1 dB @ 10 GHz to 12.4 GHz<br />

x53 AS 102-K02 N3 ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 20.8 dB @ 4 GHz to 10 GHz<br />

≥ 19.1 dB @ 10 GHz to 12.4 GHz<br />

x53 AS 102-K03 N3 ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 20.8 dB @ 4 GHz to 10 GHz<br />

≥ 19.1 dB @ 10 GHz to 12.4 GHz<br />

x53 AS 102-K06 N3 ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 20.8 dB @ 4 GHz to 10 GHz<br />

≥ 19.1 dB @ 10 GHz to 12.4 GHz<br />

x53 AS 102-K10 N3 ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 20.8 dB @ 4 GHz to 10 GHz<br />

≥ 19.1 dB @ 10 GHz to 12.4 GHz<br />

x53 AS 102-K20 N3 ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 20.8 dB @ 4 GHz to 10 GHz<br />

≥ 19.1 dB @ 10 GHz to 12.4 GHz<br />

x53 AS 102-K30 N3 ≥ 26.4 dB @ DC to 4 GHz<br />

≥ 20.8 dB @ 4 GHz to 10 GHz<br />

≥ 19.1 dB @ 10 GHz to 12.4 GHz<br />

x53 AS 105-K03 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 105-K06 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 105-K10 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 105-K20 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 105-K30 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 110-K03 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 110-K06 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 110-K10 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 110-K20 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 110-K30 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 120-K03 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 120-K06 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 120-K10 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 120-K20 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

x53 AS 120-K30 N3 ≥ 26.4 dB @ DC to 2 GHz<br />

≥ 21.2 dB @ 2 GHz to 5 GHz<br />

≥ 14.0 dB @ 5 GHz to 10 GHz<br />

1 dB ±0.3 dB @ 8 GHz<br />

±0.5 dB @ 12.4 GHz<br />

2 W @ 25 °C to<br />

0 W @ 125 °C<br />

max. 49.5<br />

2 dB ±0.3 dB @ 8 GHz<br />

±0.5 dB @ 12.4 GHz<br />

3 dB ±0.3 dB @ 8 GHz<br />

±0.5 dB @ 12.4 GHz<br />

6 dB ±0.3 dB @ 8 GHz<br />

±0.5 dB @ 12.4 GHz<br />

10 dB ±0.3 dB @ 8 GHz<br />

±0.6 dB @ 12.4 GHz<br />

20 dB ±0.3 dB @ 4 GHz<br />

±0.6 dB @ 8 GHz<br />

±0.8 dB @ 12.4 GHz<br />

30 dB ±0.3 dB @ 4 GHz<br />

±0.6 dB @ 8 GHz<br />

±1.0 dB @ 12.4 GHz<br />

3 dB ±0.3 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 10 GHz<br />

6 dB ±0.3 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 10 GHz<br />

10 dB ±0.3 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 10 GHz<br />

20 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.5 dB @ 10 GHz<br />

30 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.75 dB @ 10 GHz<br />

3 dB ±0.3 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 10 GHz<br />

6 dB ±0.3 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 10 GHz<br />

10 dB ±0.3 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 10 GHz<br />

20 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.5 dB @ 10 GHz<br />

30 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.75 dB @ 10 GHz<br />

3 dB ±0.3 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 10 GHz<br />

6 dB ±0.3 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 10 GHz<br />

10 dB ±0.3 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 10 GHz<br />

20 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.5 dB @ 10 GHz<br />

30 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.75 dB @ 10 GHz<br />

2 W @ 25 °C to<br />

0 W @ 125 °C<br />

2 W @ 25 °C to<br />

0 W @ 125 °C<br />

2 W @ 25 °C to<br />

0 W @ 125 °C<br />

2 W @ 25 °C to<br />

0 W @ 125 °C<br />

2 W @ 25 °C to<br />

0 W @ 125 °C<br />

2 W @ 25 °C to<br />

0 W @ 125 °C<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

ø 21<br />

SW18<br />

SW18<br />

SW18<br />

SW18<br />

ø 21<br />

ø 21<br />

ø 21<br />

51.5<br />

51.5<br />

56.5<br />

67<br />

93<br />

ø 20<br />

ø15.7<br />

ø 15.7<br />

ø 15.7<br />

<strong>Test</strong> Devices<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

115


<strong>Test</strong> Devices<br />

BNC 50 Ω , male-female<br />

xOrdering<br />

Number<br />

Return Loss Attenuation Power Handling<br />

x51 AS 103-K03 N4 ≥ 20.8 dB @ DC to 1.2 GHz<br />

≥ 15.5 dB @ 1.2 GHz to 2 GHz<br />

x51 AS 103-K06 N4 ≥ 20.8 dB @ DC to 1.2 GHz<br />

≥ 15.5 dB @ 1.2 GHz to 2 GHz<br />

x51 AS 103-K10 N4 ≥ 20.8 dB @ DC to 1.2 GHz<br />

≥ 15.5 dB @ 1.2 GHz to 2 GHz<br />

x51 AS 103-K20 N4 ≥ 20.8 dB @ DC to 1.2 GHz<br />

≥ 15.5 dB @ 1.2 GHz to 2 GHz<br />

x51 AS 103-K30 N4 ≥ 20.8 dB @ DC to 1.2 GHz<br />

≥ 15.5 dB @ 1.2 GHz to 2 GHz<br />

x51 AS 103-K40 N4 ≥ 20.8 dB @ DC to 1.2 GHz<br />

≥ 15.5 dB @ 1.2 GHz to 2 GHz<br />

3 dB ±0.4 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

6 dB ±0.4 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

10 dB ±0.4 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

20 dB ±0.5 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

30 dB ±1.0 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

40 dB ±1.4 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

max. 49<br />

BNC 75 Ω , male-female<br />

xOrdering<br />

Number<br />

Return Loss Attenuation Power Handling<br />

x71 AS 103-K03 N4 ≥ 23 dB @ DC to 1 GHz<br />

≥ 19 dB @ 1 GHz to 2 GHz<br />

x71 AS 103-K06 N4 ≥ 23 dB @ DC to 1 GHz<br />

≥ 19 dB @ 1 GHz to 2 GHz<br />

x71 AS 103-K10 N4 ≥ 23 dB @ DC to 1 GHz<br />

≥ 19 dB @ 1 GHz to 2 GHz<br />

x71 AS 103-K20 N4 ≥ 23 dB @ DC to 1 GHz<br />

≥ 19 dB @ 1 GHz to 2 GHz<br />

x71 AS 103-K30 N4 ≥ 23 dB @ DC to 1 GHz<br />

≥ 19 dB @ 1 GHz to 2 GHz<br />

x71 AS 103-K40 N4 ≥ 23 dB @ DC to 1 GHz<br />

≥ 19 dB @ 1 GHz to 2 GHz<br />

3 dB ±0.6 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

6 dB ±0.6 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

10 dB ±0.6 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

20 dB ±0.6 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

30 dB ±1.1 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

40 dB ±1.1 dB 3 W @ 25 °C to<br />

0 W @ 125 °C<br />

49<br />

116<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

7-16, male-female<br />

xOrdering<br />

Number<br />

Return Loss Attenuation Tolerance Power<br />

Handling<br />

x60 AS 105-K03 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 105-K06 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 105-K10 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 105-K20 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 105-K30 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 105-K40 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 110-K03 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 110-K06 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 110-K10 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 110-K20 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 110-K30 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 110-K40 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 120-K03 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 120-K06 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 120-K10 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 120-K20 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 120-K30 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

x60 AS 120-K40 N1 ≥ 30.7 dB @ DC to 1 GHz<br />

≥ 26.4 dB @ 1 GHz to 2 GHz<br />

≥ 20.0 dB @ 2 GHz to 8 GHz<br />

3 dB ±0.3 dB @ 2 GHz<br />

±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

6 dB ±0.3 dB @ 2 GHz<br />

±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

10 dB ±0.3 dB @ 2 GHz<br />

±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

20 dB ±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

30 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 8 GHz<br />

40 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.2 dB @ 8 GHz<br />

3 dB ±0.3 dB @ 2 GHz<br />

±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

6 dB ±0.3 dB @ 2 GHz<br />

±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

10 dB ±0.3 dB @ 2 GHz<br />

±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

20 dB ±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

30 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 8 GHz<br />

40 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.2 dB @ 8 GHz<br />

3 dB ±0.3 dB @ 2 GHz<br />

±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

6 dB ±0.3 dB @ 2 GHz<br />

±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

10 dB ±0.3 dB @ 2 GHz<br />

±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

20 dB ±0.4 dB @ 4 GHz<br />

±0.8 dB @ 8 GHz<br />

30 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.0 dB @ 8 GHz<br />

40 dB ±0.4 dB @ 2 GHz<br />

±0.5 dB @ 4 GHz<br />

±1.2 dB @ 8 GHz<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

5 W @ 25 °C to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

10 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

20 W @ 25 °C<br />

to<br />

0 W @ 125 °C<br />

SW32<br />

SW32<br />

SW32<br />

69<br />

69<br />

95.5<br />

51.5<br />

51.5<br />

<strong>Test</strong> Devices<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

117


<strong>Test</strong> Devices<br />

Matching Attenuators<br />

Matching Attenuators<br />

N 50 Ω male - N 75 Ω female<br />

xOrdering<br />

Number<br />

x53 S 173-K00 N3<br />

Return Loss Attenuation Power Handling<br />

≥ 26.4 dB @ DC to 1 GHz<br />

≥ 20.8 dB @ 1 to 2 GHz<br />

5.72 dB 2 W @ 25 °C to<br />

0 W @ 125 °C<br />

max. 49.5<br />

ø 21<br />

SW18<br />

ø 15.7<br />

N 50 Ω male - BNC 75 Ω female<br />

xOrdering<br />

Number<br />

Return Loss Attenuation Power Handling<br />

x53 S 171-K00 N3<br />

≥ 46 dB (male side), ≥ 44.5 dB (female side) @ DC to 30 MHz<br />

≥ 42 dB (male side), ≥ 40.1 dB (female side) @ 30 MHz to 100 MHz<br />

≥ 36.6 dB (male side), ≥ 34.1 dB (female side) @ 100 MHz to 300 MHz<br />

≥ 28.3 dB (male side), ≥ 28.3 dB (female side) @ 300 MHz to 0.5 GHz<br />

≥ 26.4 dB (male side), ≥ 23.1 dB (female side) @ 0.5 GHz to 1 GHz<br />

≥ 23.1 dB (male side), ≥ 16.5 dB (female side) @ 1 GHz to 2 GHz<br />

5.72 dB 1 W @ 25 °C to<br />

0 W @ 125 °C<br />

ø 21<br />

50.6<br />

SW18<br />

BNC 50 Ω male - BNC 75 Ω female<br />

xOrdering<br />

Number<br />

Return Loss Attenuation Power Handling<br />

x51 S 171-K00 N4<br />

≥ 46 dB (male side), ≥ 44.5 dB (female side) @ DC to 30 MHz<br />

≥ 42 dB (male side), ≥ 40.1 dB (female side) @ 30 MHz to 100 MHz<br />

≥ 36.6 dB (male side), ≥ 34.1 dB (female side) @ 100 MHz to 300 MHz<br />

≥ 28.3 dB (male side), ≥ 28.3 dB (female side) @ 300 MHz to 0.5 GHz<br />

≥ 26.4 dB (male side), ≥ 23.1 dB (female side) @ 0.5 GHz to 1 GHz<br />

≥ 23.1 dB (male side), ≥ 16.5 dB (female side) @ 1 GHz to 2 GHz<br />

5.72 dB 1 W @ 25 °C to<br />

0 W @ 125 °C<br />

max. 49<br />

SW11<br />

SW12.7<br />

BNC 50 Ω female - BNC 75 Ω male<br />

xOrdering<br />

Number<br />

Return Loss Attenuation Power Handling<br />

x51 K 171-S00 N4<br />

≥ 46 dB (male side), ≥ 44.5 dB (female side) @ DC to 30 MHz<br />

≥ 42 dB (male side), ≥ 40.1 dB (female side) @ 30 MHz to 100 MHz<br />

≥ 36.6 dB (male side), ≥ 34.1 dB (female side) @ 100 MHz to 300 MHz<br />

≥ 28.3 dB (male side), ≥ 28.3 dB (female side) @ 300 MHz to 0.5 GHz<br />

≥ 26.4 dB (male side), ≥ 23.1 dB (female side) @ 0.5 GHz to 1 GHz<br />

≥ 23.1 dB (male side), ≥ 16.5 dB (female side) @ 1 GHz to 2 GHz<br />

5.72 dB 1 W @ 25 °C to<br />

0 W @ 125 °C<br />

max. 49<br />

SW12.7<br />

SW11<br />

118<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

Tools<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

Remarks<br />

x01 W 021-000<br />

flat 6 mm - 35 Ncm torque for RPC-1.00<br />

136.5<br />

x03 W 021-000<br />

flat 8 mm - 0.9 Nm torque for RPC-3.50 , RPC- 2.92, RPC-2.40, RPC-1.85<br />

136.5<br />

x04 W 021-000<br />

flat 18 mm - 2 Nm torque for RPC-SL 26.5 GHz, RPC-SL 40 GHz<br />

157<br />

<strong>Test</strong> Devices<br />

x06 W 021-000<br />

flat 15 mm - 55 Ncm torque for RPC-TNC<br />

152<br />

x07 W 021-000<br />

flat 19 mm - 136 Ncm torque for RPC 7, RPC-SP<br />

157<br />

x53 W 009-000<br />

flat 20 mm - 1,1 Nm torque for RPC-N 50 Ω , RPC-N 75 Ω<br />

155<br />

Collet Extractor<br />

xOrdering Number<br />

x07 W 031-000<br />

for RPC-7, to remove 7 mm center contact<br />

91.7<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

119


<strong>Test</strong> Devices<br />

Gauges<br />

Gauge incl. Block RPC-N 50 Ω , RPC-N 75 Ω<br />

xOrdering Number<br />

x05 W 00S-000<br />

xP5 W 00S-000<br />

Remarks<br />

compatible to male connectors for RPC-N 50 Ω<br />

incl. gauge block<br />

compatible to male connectors for RPC-N 75 Ω<br />

incl. gauge block<br />

36.2<br />

SW13<br />

ø17.4<br />

x05 W 00K-000<br />

compatible to female connectors for RPC-N 50 Ω , RPC-N 75 Ω<br />

incl. gauge block<br />

36<br />

SW20<br />

ø16<br />

Gauge incl. Block RPC-TNC<br />

xOrdering Number<br />

x06 W 00S-000<br />

Remarks<br />

compatible to male connectors for RPC-TNC<br />

incl. gauge block<br />

1<br />

ø11.8<br />

x06 W 00K-000<br />

compatible to female connectors for RPC-TNC<br />

incl. gauge block<br />

29.5<br />

27.1<br />

ø11.8<br />

SW15<br />

120<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

Gauge incl. Block RPC-7<br />

xOrdering Number<br />

x07 W 001-000<br />

Remarks<br />

compatible to connectors for RPC-7<br />

incl. gauge block<br />

25<br />

ø14<br />

SW19<br />

<strong>Test</strong> Devices<br />

Gauge incl. Block RPC-3.50, RPC-2.92<br />

xOrdering Number Remarks<br />

x03 W 00S-000<br />

compatible to male connectors for RPC-3.50, RPC-2.92<br />

incl. gauge block<br />

ø15<br />

x03 W 00K-000<br />

compatible to female connectors for RPC-3.50, RPC-2.92<br />

incl. gauge block<br />

30<br />

33<br />

ø15<br />

SW8<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

121


<strong>Test</strong> Devices<br />

Gauge incl. Block RPC-2.40, RPC-1.85<br />

xOrdering Number<br />

x08 W 00S-000<br />

Remarks<br />

compatible to male connectors for RPC-2.40, RPC-1.85<br />

incl. gauge block<br />

ø15<br />

x08 W 00K-000<br />

compatible to female connectors for RPC-2.40, RPC-1.85<br />

incl. gauge block<br />

30<br />

34.2<br />

ø15<br />

SW8<br />

Gauge incl. Block RPC-1.00<br />

xOrdering Number Remarks<br />

x01 W 00S-000<br />

compatible to male connectors for RPC-1.00<br />

incl. gauge block<br />

ø10<br />

x01 W 00K-000<br />

compatible to female connectors for RPC-1.00<br />

incl. gauge block<br />

30<br />

32.2<br />

ø10<br />

SW6<br />

122<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Test</strong> Devices<br />

Gauge incl. Block 7-16<br />

xOrdering Number<br />

Remarks<br />

x60 W 00S-000 compatible to male connectors for 7-16<br />

incl. gauge block<br />

1<br />

x60 W 00K-000 compatible to female connectors for 7-16<br />

incl. gauge block<br />

ø17.4<br />

32<br />

43.3<br />

<strong>Test</strong> Devices<br />

ø 21<br />

SW32<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

123


<strong>Rosenberger</strong> RPC-N connectors with an outer diameter of<br />

7 mm have been designed for applications up to 18 GHz (50 Ohm),<br />

75 Ω types up to 4 GHz.<br />

<strong>Rosenberger</strong> RPC-N-Steckverbinder – Präzisionssteckverbinder<br />

mit 7 mm-Außenleiter – wurden konzipiert für Anwendungen<br />

bis 18 GHz, die 75 Ω-Ausführungen können bis 4 GHz<br />

eingesetzt werden.<br />

RPC-N precision connectors are intermateable with standard<br />

N connectors 50 Ω, but not to 75 Ω types. RPC-N and RPC-7<br />

connector heads are interchangeable using the same bead type.<br />

RPC-N-Präzisionssteckverbinder sind steckkompatibel zu<br />

Standard-N-Steckverbindern, 50 Ω, jedoch nicht zu 75 Ω-Typen.<br />

Die Steckverbinderköpfe von RPC-N und RPC-7-Steckverbindern<br />

sind aufgrund gleicher Anschlussmaße auf der<br />

Montageseite austauschbar.<br />

Additionally, the RPC-N product spectrum includes cable connectors,<br />

adapters, as well as test & measurement accessories such as<br />

calibration kits, verification kits, attenuators, mismatches, airlines<br />

or sliding loads.<br />

Das Produktspektrum umfasst Kabelsteckverbinder, Adapter,<br />

sowie Messzubehör wie z. B. RPC-N-Kalibrier-Kits, Verifizier-<br />

Kits, Dämpfungsglieder, Fehlabschlüsse, Luftleitungen oder<br />

Gleitlasten.


Series RPC-N<br />

RPC-N<br />

Features<br />

Interface according to IEC 61169-16<br />

Frequency range DC to 18 GHz / 4 GHz<br />

Return loss (connector head) >- 30 dB / 36 dB<br />

Impedance 50 Ω / 75 Ω<br />

Threaded coupling<br />

Intermateable with standard N<br />

No coupling between 50 Ω and 75 Ω


Series RPC-N, 50 Ω<br />

1Series RPC- N, 50 Ω<br />

Interface Dimensions Series RPC-N, 50 Ω (code 05)<br />

REFERENCE PLANE<br />

Referenzebene<br />

REFERENCE PLANE<br />

Referenzebene<br />

D<br />

D<br />

A<br />

E<br />

B<br />

C<br />

F<br />

F<br />

C<br />

E<br />

A<br />

MALE<br />

Stecker<br />

FEMALE<br />

Kuppler<br />

Series RPC-N, 50 Ω<br />

Male | Stecker<br />

Female | Kuppler<br />

dimension min. max. min. max.<br />

A 3.03 3.05 3.03 3.05<br />

B 6.99 7.01 6.99 7.01<br />

C 7.98 8.02 8.05 8.10<br />

D 5.28 5.36 5.18 5.26<br />

E 1.64 1.66 1.68 1.71<br />

F 5/8-24UNEF-2B 5/8-24UNEF-2A<br />

126<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-N, 50 Ω<br />

Technology<br />

Technical Data Series RPC-N, 50 Ω<br />

Applicable standards | Anwendbare Standards<br />

Interface according to | Interface gemäß IEC 61169-16; CECC 22 210; MIL-STD 348A/402<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (connector head) | Rückflußdämpfung (Steckerkopf)<br />

Insertion loss (connector head) | Dämpfung (Steckerkopf)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

50 Ω<br />

DC to 18 GHz<br />

≥ 30 dB, DC to 18 GHz<br />

≤ 0.03 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 1.0 mΩ<br />

≤ 1.0 mΩ<br />

2500 V rms<br />

1000 V rms<br />

≥ 90 dB up to 1 GHz<br />

RPC-N<br />

Mating cycles | Steckzyklen ≥ 500<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 28 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

0.70 Nm to 1.10 Nm<br />

Coupling test torque | Prüfdrehmoment<br />

1.70 Nm<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen IEC 61169-1, Subclause 9.4.4<br />

Corrosion resistance | Korrosionsbeständigkeit IEC 61169-1, Subclause 9.4.6<br />

Vibration | Vibration IEC 61169-1, Subclause 9.3.3<br />

Shock | Schock IEC 61169-1, Subclause 9.3.14<br />

Moisture resistance | Feuchtigkeitsbeständigkeit IEC 61169-1, Subclause 9.4.3<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Stainless steel, passivated<br />

PPE<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

127


Series RPC-N, 50 Ω<br />

Connector Heads<br />

Connector Heads<br />

Straight Plug<br />

xOrdering Number Version Remarks Return Loss<br />

x05 S 121-000 S3 straight with bead ≥ 30 dB @ DC to 18 GHz<br />

29.3<br />

ø15.7<br />

SW20<br />

SW14<br />

Straight Jack<br />

xOrdering Number Version Remarks Return Loss<br />

x05 K 121-000 S3 straight with bead ≥ 30 dB @ DC to 18 GHz<br />

28.0<br />

ø15.7<br />

SW14<br />

Cable Connectors Semi- Rigid Cable<br />

Cable Connectors Semi-Rigid Cable<br />

Straight Plug, solder<br />

xOrdering Number Remarks Return Loss Cable Group Assembly Instruction<br />

x05 S 121-271 S3 a = 48.1 mm ≥ 25 dB @ DC to 18 GHz 71 02 A3<br />

x05 S 121-272 S3 a = 41.2 mm ≥ 25 dB @ DC to 18 GHz 72 02 A3<br />

x05 S 121-273 S3 a = 48.1 mm ≥ 25 dB @ DC to 18 GHz 73 03 A<br />

a<br />

Semi-Rigid<br />

SW20<br />

SW14<br />

Straight Jack, solder<br />

xOrdering Number Remarks Return Loss Cable Group Assembly Instruction<br />

x05 K 121-271 S3 a = 46.9 mm ≥ 25 dB @ DC to 18 GHz 71 02 A3<br />

x05 K 121-272 S3 a = 40.0 mm ≥ 25 dB @ DC to 18 GHz 72 03 A<br />

x05 K 121-273 S3 a = 46.9 mm ≥ 25 dB @ DC to 18 GHz 73 03 A<br />

a<br />

Semi-Rigid<br />

SW14<br />

Panel Jack, round flange<br />

xOrdering Number Remarks Return Loss Cable Group Assembly<br />

Instruction<br />

x05 K 521-271 S3 a = 46.9 mm ≥ 25 dB @ DC to 18 GHz 71 02 A3 MB 13<br />

x05 K 521-272 S3 a = 40.0 mm ≥ 25 dB @ DC to 18 GHz 72 03 A MB 13<br />

x05 K 521-273 S3 a = 46.9 mm ≥ 25 dB @ DC to 18 GHz 73 03 A MB 13<br />

Panel Piercing /<br />

PCB Layout<br />

23<br />

a<br />

Semi-Rigid<br />

ø 22<br />

128<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-N, 50 Ω<br />

Adaptors<br />

Adaptors<br />

Adaptor (In Series)<br />

xOrdering Number Version Remarks Return Loss Panel Piercing<br />

/ PCB Layout<br />

x05 S 121-S00 S3 straight RPC-N 50 Ω male - male ≥ 26 dB @ DC to 18 GHz<br />

x05 S 121-S20 S3 straight RPC-N 50 Ω male - male,<br />

calibration adaptor<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 18 GHz<br />

47.4<br />

SW20<br />

SW20<br />

x05 S 121-K00 S3 straight RPC-N 50 Ω male - female ≥ 26 dB @ DC to 18 GHz<br />

x05 S 121-K20 S3 straight RPC-N 50 Ω male - female,<br />

calibration adaptor<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 18 GHz<br />

55.3<br />

x05 K 121-K00 S3 straight RPC-N 50 Ω female - female ≥ 26 dB @ DC to 18 GHz<br />

x05 K 121-K20 S3 straight RPC-N 50 Ω female - female,<br />

calibration adaptor<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 18 GHz<br />

SW20<br />

63.1<br />

RPC-N<br />

x05 K 521-K00 S3 straight RPC-N 50 Ω female - female,<br />

round flange<br />

≥ 26 dB @ DC to 18 GHz MB 13<br />

43.6<br />

ø22<br />

SW14<br />

SW13.5<br />

SW19<br />

Adaptor (Inter Series)<br />

xOrdering Number Version Remarks Return Loss Panel<br />

Piercing /<br />

PCB<br />

Layout<br />

x05 S 106-S00 S3 straight RPC-N 50 Ω male - RPC-TNC male ≥ 20 dB @ DC to 18 GHz<br />

x05 S 106-S20 S3 straight RPC-N 50 Ω male - RPC-TNC male,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

52.5<br />

SW20 SW14<br />

SW14<br />

SW15<br />

x05 S 106-K00 S3 straight RPC-N 50 Ω male - RPC-TNC female ≥ 20 dB @ DC to 18 GHz<br />

53.6<br />

SW20<br />

SW14<br />

SW14<br />

x05 K 106-S00 S3 straight RPC-N 50 Ω female - RPC-TNC male ≥ 20 dB @ DC to 18 GHz<br />

46<br />

SW14<br />

SW14<br />

SW15<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

129


Series RPC-N, 50 Ω<br />

xOrdering Number Version Remarks Return Loss Panel<br />

Piercing /<br />

PCB<br />

Layout<br />

x05 K 106-K00 S3 straight RPC-N 50 Ω female - RPC-TNC<br />

female<br />

x05 K 106-K20 S3 straight RPC-N 50 Ω female - RPC-TNC<br />

female,<br />

calibration adaptor<br />

≥ 20 dB @ DC to 18 GHz<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

47.2<br />

SW14<br />

SW14<br />

x05 S 132-S00 S3 straight RPC-N 50 Ω male - SMA male ≥ 23 dB @ DC to 18 GHz<br />

45<br />

SW20<br />

SW14<br />

SW8<br />

x05 S 132-K00 S3 straight RPC-N 50 Ω male - SMA female ≥ 23 dB @ DC to 18 GHz<br />

43.1<br />

SW20<br />

SW14<br />

SW13<br />

x05 K 132-S00 S3 straight RPC-N 50 Ω female - SMA male ≥ 23 dB @ DC to 18 GHz<br />

43.8<br />

SW 14<br />

SW 8<br />

x05 K 132-K00 S3 straight RPC-N 50 Ω female - SMA female ≥ 23 dB @ DC to 18 GHz<br />

41.9<br />

SW14<br />

SW13<br />

x05 S 432-S00 S3 straight RPC-N 50 Ω male - SMA male,<br />

4-hole flange<br />

≥ 23 dB @ DC to 18 GHz MB 12<br />

41.3<br />

25.4<br />

SW20<br />

SW14<br />

SW8<br />

x05 S 432-K00 S3 straight RPC-N 50 Ω male - SMA female,<br />

4-hole flange<br />

≥ 23 dB @ DC to 18 GHz MB 12<br />

39.4<br />

25.4<br />

SW20<br />

SW14<br />

x05 K 432-S00 S3 straight RPC-N 50 Ω female - SMA male,<br />

4-hole flange<br />

≥ 23 dB @ DC to 18 GHz MB 12<br />

40.2<br />

25.4<br />

SW 14<br />

SW 8<br />

130<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-N, 50 Ω<br />

xOrdering Number Version Remarks Return Loss Panel<br />

Piercing /<br />

PCB<br />

Layout<br />

x05 K 432-K00 S3 straight RPC-N 50 Ω female - SMA female,<br />

4-hole flange<br />

≥ 23 dB @ DC to 18 GHz MB 12<br />

38.4<br />

25.4<br />

SW 14<br />

x05 S 160-S50 D3 straight RPC-N 50 Ω male - 7-16 male,<br />

calibration adaptor<br />

≥ 36.6 dB @ DC to 8 GHz<br />

50<br />

x05 S 160-K50 D3 straight RPC-N 50 Ω male - 7-16 female,<br />

calibration adaptor<br />

≥ 36.6 dB @ DC to 8 GHz<br />

SW20<br />

SW32<br />

51.5<br />

RPC-N<br />

SW20<br />

x05 K 160-S50 D3 straight RPC-N 50 Ω female - 7-16 male,<br />

calibration adaptor<br />

≥ 36.6 dB @ DC to 8 GHz<br />

49<br />

SW32<br />

x05 K 160-K50 D3 straight RPC-N 50 Ω female - 7-16 female,<br />

calibration adaptor<br />

≥ 36.6 dB @ DC to 8 GHz<br />

51<br />

x05 S 151-S00 S3 straight RPC-N 50 Ω male - BNC 50 Ω male ≥ 22 dB @ DC to 4 GHz<br />

x05 S 151-S20 S3 straight RPC-N 50 Ω male - BNC 50 Ω male,<br />

calibration adaptor<br />

≥ 36 dB @ DC to 2 GHz<br />

≥ 30 dB @ 2 GHz to 4 GHz<br />

49.2<br />

SW 20 SW 14 SW 13<br />

x05 S 151-K00 S3 straight RPC-N 50 Ω male - BNC 50 Ω female ≥ 22 dB @ DC to 4 GHz<br />

45.4<br />

SW20<br />

SW14<br />

SW13<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

131


Series RPC-N, 50 Ω<br />

xOrdering Number Version Remarks Return Loss Panel<br />

Piercing /<br />

PCB<br />

Layout<br />

x05 K 151-S00 S3 straight RPC-N 50 Ω female - BNC 50 Ω male ≥ 22 dB @ DC to 4 GHz<br />

48<br />

SW14<br />

SW13<br />

x05 K 151-K00 S3 straight RPC-N 50 Ω female - BNC 50 Ω<br />

female<br />

x05 K 151-K20 S3 straight RPC-N 50 Ω female - BNC 50 Ω<br />

female, calibration adaptor<br />

≥ 22 dB @ DC to 4 GHz<br />

≥ 36 dB @ DC to 2 GHz<br />

≥ 30 dB @ 2 GHz to 4 GHz<br />

44.2<br />

SW14<br />

SW13<br />

x05 S 107-P00 S3 straight RPC-N 50 Ω male - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

45<br />

ø 22<br />

SW20<br />

SW14<br />

SW19<br />

x05 K 107-P00 S3 straight RPC-N 50 Ω female - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

38.6<br />

ø 22<br />

SW14<br />

SW19<br />

x03 S 105-S00 S3 straight RPC-3.50 male - RPC-N 50 Ω male ≥ 26 dB @ DC to 18 GHz<br />

45<br />

ø 15.7<br />

ø 19<br />

SW8<br />

SW14<br />

SW20<br />

x03 S 105-K00 S3 straight RPC-3.50 male - RPC-N 50 Ω female ≥ 26 dB @ DC to 18 GHz<br />

43.8<br />

ø 15.7<br />

SW8 SW14 SW14<br />

x03 K 105-S00 S3 straight RPC-3.50 female - RPC-N 50 Ω male ≥ 26 dB @ DC to 18 GHz<br />

43.1<br />

ø 16<br />

ø 15.7<br />

SW13<br />

SW14<br />

SW20<br />

x03 K 105-K00 S3 straight RPC-3.50 female - RPC-N 50 Ω<br />

female<br />

≥ 26 dB @ DC to 18 GHz<br />

41.8<br />

ø 15.7<br />

SW13<br />

SW14<br />

132<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-N, 50 Ω<br />

xOrdering Number Version Remarks Return Loss Panel<br />

Piercing /<br />

PCB<br />

Layout<br />

x03 KR 105-S00 S3 straight RPC-3.50 female, ruggedized -<br />

RPC-N 50 Ω male<br />

≥ 26 dB @ DC to 18 GHz<br />

44.8<br />

ø 22<br />

x03 KR 105-K00 S3 straight RPC-3.50 female, ruggedized -<br />

RPC-N 50 Ω female<br />

≥ 26 dB @ DC to 18 GHz<br />

SW19<br />

43.8<br />

SW20<br />

ø 22<br />

ø 15.7<br />

x53 QS 105-S00 S3 straight SnapN male - RPC-N 50 Ω male ≥ 26 dB @ DC to 11 GHz<br />

SW19<br />

SW14<br />

60.44<br />

RPC-N<br />

x53 QS 105-K00 S3 straight SnapN male - RPC-N 50 Ω female ≥ 26 dB @ DC to 11 GHz<br />

SW14<br />

SW14<br />

59.2<br />

SW20<br />

ø15.7<br />

SW14<br />

SW14<br />

x53 QS 105-K20 S3 straight SnapN male - RPC-N 50 Ω female<br />

calibration adaptor<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 27 dB @ 4 GHz to 11 GHz<br />

50.6<br />

SW14<br />

SW16<br />

x53 QK 105-S00 S3 straight SnapN female - RPC-N 50 Ω male ≥ 28 dB @ DC to 11 GHz<br />

≥ 26 dB @ 11 GHz to 18 GHz<br />

44.9<br />

ø 15.7<br />

SW14 SW14<br />

SW20<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

133


Series RPC-N, 50 Ω<br />

xOrdering Number Version Remarks Return Loss Panel<br />

Piercing /<br />

PCB<br />

Layout<br />

x53 QK 105-S20 S3 straight SnapN female - RPC-N 50 Ω male<br />

calibration adaptor<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 27 dB @ 4 GHz to 11 GHz<br />

52<br />

ø 15.7<br />

x53 QK 105-K00 S3 straight SnapN female - RPC-N 50 Ω female ≥ 28 dB @ DC to 11 GHz<br />

≥ 26 dB @ 11 GHz to 18 GHz<br />

SW 16 SW 20<br />

43.6<br />

ø 15.7<br />

SW14<br />

SW14<br />

x02 KR 105-K00 S3 straight RPC-2.92 female, ruggedized -<br />

RPC-N 50 Ω female<br />

≥ 26 dB @ DC to 18 GHz<br />

43.8<br />

ø 22<br />

ø 15.7<br />

SW19<br />

SW14<br />

x02 KR 105-S00 S3 straight RPC-2.92 female, ruggedized -<br />

RPC-N 50 Ω male<br />

≥ 26 dB @ DC to 18 GHz<br />

44.84<br />

ø 22<br />

SW19<br />

SW20<br />

DC- Block<br />

DC-Block<br />

DC-Block RPC-N 50 Ω male - female<br />

xOrdering Number Version Return Loss Insertion Loss<br />

x05 DS 121-K00 S3 straight ≥ 25 dB @ 3 MHz to 18 GHz < 1 dB @ 3 MHz to 18 GHz<br />

47.5<br />

ø17<br />

SW20<br />

SW15<br />

134<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-N, 50 Ω<br />

Interchangeable Port Connector System<br />

Interchangeable Port Connector System<br />

RPC-N 50 Ω - RPC-SL 26.5 GHz<br />

xOrdering Number Version Remarks Return Loss<br />

x05 S 104-S00 S3 straight RPC-N 50 Ω male - RPC-SL 26.5 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz<br />

33<br />

x05 K 104-S00 S3 straight RPC-N 50 Ω female - RPC-SL 26.5 GHz<br />

male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz<br />

SW20<br />

SW18<br />

31.8<br />

SW14<br />

SW18<br />

RPC-N<br />

RPC-N 50 Ω - RPC-SL 40 GHz<br />

xOrdering Number Version Remarks Return Loss<br />

x05 S 1P4-S00 S3 straight RPC-N 50 Ω male - RPC-SL 40 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz<br />

33<br />

SW20<br />

SW18<br />

x05 K 1P4-S00 S3 straight RPC-N 50 Ω female - RPC-SL 40 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz<br />

31.8<br />

SW14<br />

SW18<br />

see also chapter interchangeable port connector system<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

135


Series RPC-N, 50 Ω<br />

Tools<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

x53 W 009-000<br />

Remarks<br />

flat 20 mm - 1,1 Nm torque for RPC-N 50 Ω , RPC-N 75 Ω<br />

155<br />

Gauge<br />

xOrdering Number<br />

x05 W 00S-000<br />

Remarks<br />

compatible to male connectors for RPC-N 50 Ω<br />

incl. gauge block<br />

36.2<br />

SW13<br />

ø17.4<br />

x05 W 00K-000<br />

compatible to female connectors for RPC-N 50 Ω , RPC-N 75 Ω<br />

incl. gauge block<br />

36<br />

SW20<br />

ø16<br />

136<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-N, 50 Ω<br />

RPC-N<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

137


Series RPC-N, 75 Ω<br />

2Series RPC- N, 75 Ω<br />

Interface Dimensions Series RPC-N, 75 Ω (code P5)<br />

REFERENCE PLANE<br />

Referenzebene<br />

REFERENCE PLANE<br />

Referenzebene<br />

D<br />

D<br />

A<br />

E<br />

B<br />

C<br />

F<br />

F<br />

C<br />

E<br />

A<br />

MALE<br />

Stecker<br />

FEMALE<br />

Kuppler<br />

Series RPC-N, 75 Ω<br />

Male | Stecker<br />

Female | Kuppler<br />

dimension min. max. min. max.<br />

A 2.00 2.02 2.00 2.02<br />

B 6.99 7.01 6.99 7.01<br />

C 7.98 8.02 8.05 8.10<br />

D 5.28 5.36 5.18 5.26<br />

E 0.864 0.914<br />

F 5/8-24UNEF-2B 5/8-24UNEF-2A<br />

138<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-N, 75 Ω<br />

Technology<br />

Technical Data Series RPC-N, 75 Ω<br />

Applicable standards | Anwendbare Standards<br />

Interface according to | Interface gemäß IEC 61169-16; CECC 22 210; MIL-STD 348A/402<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (connector head) | Rückflußdämpfung (Steckerkopf)<br />

Insertion loss (connector head) | Dämpfung (Steckerkopf)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

75 Ω<br />

DC to 4 GHz<br />

≥ 36 dB, DC to 4 GHz<br />

≤ 0.03 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 1.0 mΩ<br />

≤ 1.0 mΩ<br />

2500 V rms<br />

1000 V rms<br />

≥ 90 dB up to 1 GHz<br />

RPC-N<br />

Mating cycles | Steckzyklen ≥ 500<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 28 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

0.70 Nm to 1.10 Nm<br />

Coupling test torque | Prüfdrehmoment<br />

1.70 Nm<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen IEC 61169-1, Subclause 9.4.4<br />

Corrosion resistance | Korrosionsbeständigkeit IEC 61169-1, Subclause 9.4.6<br />

Vibration | Vibration IEC 61169-1, Subclause 9.3.3<br />

Shock | Schock IEC 61169-1, Subclause 9.3.14<br />

Moisture resistance | Feuchtigkeitsbeständigkeit IEC 61169-1, Subclause 9.4.3<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Stainless steel, passivated<br />

PS, PEI<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

139


Series RPC-N, 75 Ω<br />

Connector Heads<br />

Connector Heads<br />

Straight Plug<br />

xOrdering Number Remarks Return Loss<br />

xP5 S 121-000 CS with bead ≥ 36 dB @ DC to 4 GHz<br />

30.2<br />

ø15.7<br />

SW20<br />

Straight Jack<br />

xOrdering Number Remarks Return Loss<br />

xP5 K 121-000 CS with bead ≥ 36 dB @ DC to 4 GHz<br />

29<br />

ø15.7<br />

SW20<br />

Adaptors<br />

Adaptors<br />

Adaptor (In Series)<br />

xOrdering Number Version Remarks Return Loss<br />

xP5 S 121-S20 CS straight RPC-N 75 Ω male - male,<br />

calibration adaptor<br />

≥ 38 dB @ DC to 2 GHz<br />

≥ 34 dB @ 2 GHz to 4 GHz<br />

47.7<br />

SW20<br />

SW20<br />

xP5 K 121-K20 CS straight RPC-N 75 Ω female - female,<br />

calibration adaptor<br />

≥ 38 dB @ DC to 2 GHz<br />

≥ 34 dB @ 2 GHz to 4 GHz<br />

63.4<br />

Adaptor (Inter Series)<br />

xOrdering Number Version Remarks Return Loss<br />

xP5 S 174-S20 CS straight RPC-N 75 Ω male - F male,<br />

calibration adaptor<br />

≥ 32 dB @ DC to 3 GHz<br />

≥ 28 dB @ 3 GHz to 4 GHz<br />

50.1<br />

ø15.7<br />

SW20<br />

SW14<br />

SW12<br />

SW12<br />

xP5 K 174-K20 CS straight RPC-N 75 Ω female - F female,<br />

calibration adaptor<br />

≥ 32 dB @ DC to 3 GHz<br />

≥ 28 dB @ 3 GHz to 4 GHz<br />

42.3<br />

ø15.7<br />

SW14<br />

SW13<br />

140<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-N, 75 Ω<br />

DC- Block<br />

DC-Block<br />

DC-Block RPC-N 75 Ω male - female<br />

xOrdering Number Version Return Loss Insertion Loss<br />

xP5 DS 121-K01 CS straight ≥ 25 dB @ 4 MHz to 1 GHz<br />

≥ 21 dB @ 1 GHz to 4 GHz<br />

< 1 dB @ 4 MHz to 4 GHz 1<br />

64.6<br />

ø15.7<br />

SW20 SW14 SW14 SW14<br />

Tools<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

x53 W 009-000<br />

Remarks<br />

flat 20 mm - 1,1 Nm torque for RPC-N 50 Ω , RPC-N 75 Ω<br />

155<br />

RPC-N<br />

Gauge<br />

xOrdering Number<br />

Remarks<br />

xP5 W 00S-000<br />

compatible to male connectors for RPC-N 75 Ω<br />

incl. gauge block<br />

36.2<br />

SW13<br />

ø17.4<br />

x05 W 00K-000<br />

compatible to female connectors for RPC-N 50 Ω , RPC-N 75 Ω<br />

incl. gauge block<br />

36<br />

SW20<br />

ø16<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

141


<strong>Rosenberger</strong> RPC-TNC precision connectors – with threaded<br />

coupling – have been designed for applications up to 18 GHz.<br />

Interface dimensions are based on BNC series interface.<br />

<strong>Rosenberger</strong> RPC-TNC precision connectors are intermateable<br />

with standard TNC connectors, 50 Ω and 75 Ω types both.<br />

<strong>Rosenberger</strong> RPC-TNC-Präzisionssteckverbinder – mit Schraubverbindung<br />

– eignen sich für Anwendungen bis 18 GHz. Die<br />

Interface-Abmessungen entsprechen dem Interface von BNC-<br />

Steckverbindern. <strong>Rosenberger</strong> RPC-TNC-Steckverbinder<br />

sind steckkompatibel zu Standard-TNC-Steckverbindern,<br />

50 Ω und 75 Ω-Typen.<br />

The wide product range includes cable connectors, adapters,<br />

as well as test & measurement accessories such as calibration kits<br />

or test devices (open – short – load).<br />

Das umfangreiche Produktspektrum umfasst Kabelsteckverbinder,<br />

Adapter, sowie Messzubehör wie RPC-TNC-Kalibrier-<br />

Kits oder <strong>Test</strong>-Komponenten (Open – Short – Load).


Series RPC-TNC<br />

RPC-TNC<br />

Features<br />

Interface according to IEC 60169-26<br />

Frequency range DC to 18 GHz<br />

Return loss (connector head) ≥ 23 dB<br />

Impedance 50 Ω<br />

Threaded coupling<br />

Intermateable with standard TNC


Series RPC-TNC<br />

1Series RPC- TNC<br />

Interface Dimensions Series RPC-TNC (code 06)<br />

D<br />

REFERENCE PLANE<br />

Referenzebene<br />

REFERENCE PLANE<br />

Referenzebene<br />

D<br />

A<br />

E<br />

C<br />

B<br />

F<br />

F<br />

B<br />

C<br />

E<br />

A<br />

MALE<br />

Stecker<br />

FEMALE<br />

Kuppler<br />

Series RPC-TNC<br />

Male | Stecker<br />

Female | Kuppler<br />

dimension min. max. min. max.<br />

A 1.64 1.66 2.13 2.15<br />

B 8.06 8.08 8.10 8.15<br />

C 6.07 6.12 4.62 4.72<br />

D 5.28 5.38 5.18 5.28<br />

E 1.34 1.37 1.38 1.41<br />

F 7/16-28UNEF-2B 7/16-28UNEF-2A<br />

144<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-TNC<br />

Technology<br />

Technical Data Series RPC-TNC<br />

Applicable standards | Anwendbare Standards<br />

Interface according to | Interface gemäß IEC 60169-26<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (connector head) | Rückflußdämpfung (Steckerkopf)<br />

Insertion loss (connector head) | Dämpfung (Steckerkopf)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

50 Ω<br />

DC to 18 GHz<br />

≥ 23 dB, DC to 18 GHz<br />

≤ 0.05 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 1.5 mΩ<br />

≤ 1.0 mΩ<br />

1500 V rms<br />

500 V rms<br />

≥ 90 dB up to 1 GHz<br />

Mating cycles | Steckzyklen ≥ 500<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 27 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

0.46 Nm to 0.69 Nm<br />

Coupling test torque | Prüfdrehmoment<br />

1.70 Nm<br />

Environmental data | Umweltdaten<br />

RPC-TNC<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen<br />

MIL-STD 202, Method 107, Condition B<br />

Corrosion resistance | Korrosionsbeständigkeit<br />

MIL-STD 202, Method 101, Condition B<br />

Vibration | Vibration<br />

MIL-STD 202, Method 204, Condition D<br />

Shock | Schock<br />

MIL-STD 202, Method 213, Condition I<br />

Moisture resistance | Feuchtigkeitsbeständigkeit MIL-STD 202, Method 106<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric 1 | Dielektrikum 1<br />

Dielectric 2 | Dielektrikum 2<br />

Gasket | Dichtung<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Stainless steel, passivated<br />

PTFE<br />

PPE<br />

Neoprene E50<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

145


Series RPC-TNC<br />

Connector Heads<br />

Connector Heads<br />

Straight Plug<br />

xOrdering Number Remarks Return Loss<br />

x06 S 121-000 S3 with bead ≥ 23 dB @ DC to 18 GHz<br />

x06 S 121-002 S3 with bead, coupling nut without wire-lock ≥ 23 dB @ DC to 18 GHz<br />

30.3<br />

ø15.7<br />

SW15<br />

SW14<br />

Straight Jack<br />

xOrdering Number Remarks Return Loss<br />

x06 K 121-000 S3 with bead ≥ 23 dB @ DC to 18 GHz<br />

31.4<br />

ø 15.7<br />

SW14<br />

Adaptors<br />

Adaptors<br />

Adaptor (In Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x06 S 121-S20 S3 straight RPC-TNC male - male,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 to 18 GHz<br />

ø15.7<br />

65.1<br />

SW14<br />

SW10 SW14<br />

SW15<br />

x06 S 121-K20 S3 straight RPC-TNC male - female,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 to 18 GHz<br />

66.4<br />

ø15.7<br />

SW15<br />

SW14<br />

SW10<br />

SW14<br />

x06 K 121-K20 S3 straight RPC-TNC female - female,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 to 18 GHz<br />

67.8<br />

ø15.7<br />

SW14<br />

SW10<br />

SW14<br />

146<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-TNC<br />

Adaptor (Inter Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x06 S 132-S00 S3 straight RPC-TNC male - SMA male ≥ 19 dB @ DC to 18 GHz<br />

45.9<br />

ø 15.7<br />

SW15<br />

SW14<br />

SW14<br />

SW8<br />

x06 S 132-K00 S3 straight RPC-TNC male - SMA female ≥ 19 dB @ DC to 18 GHz<br />

45.4<br />

ø 15.7<br />

SW15<br />

SW14<br />

SW13<br />

x06 K 132-S00 S3 straight RPC-TNC female - SMA male ≥ 19 dB @ DC to 18 GHz<br />

47.3<br />

ø 15.7<br />

SW14<br />

SW14<br />

SW8<br />

x06 K 132-K00 S3 straight RPC-TNC female - SMA female ≥ 19 dB @ DC to 18 GHz<br />

45.4<br />

RPC-TNC<br />

ø 15.7<br />

SW14<br />

SW13<br />

x06 S 107-P20 S3 straight RPC-TNC male - RPC-7,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 to 18 GHz<br />

43<br />

ø 22<br />

SW15<br />

SW13<br />

SW19<br />

x06 K 107-P20 S3 straight RPC-TNC female - RPC-7,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 to 18 GHz<br />

53<br />

ø 22<br />

SW13<br />

SW19<br />

x03 K 706-S23 S3 straight RPC-3.50 female - RPC-TNC male,<br />

2-hole flange,<br />

floating test adaptor<br />

≥ 35 dB @ DC to 2.5 GHz<br />

≥ 25 dB @ 2.5 GHz to 6 GHz<br />

≥ 20 dB @ 6 GHz to 16 GHz<br />

≥ 17 dB @ 16 GHz to 18 GHz<br />

43.5<br />

ø 20.7<br />

ø 32<br />

SW16<br />

SW15<br />

x05 S 106-S00 S3 straight RPC-N 50 Ω male - RPC-TNC male ≥ 20 dB @ DC to 18 GHz<br />

x05 S 106-S20 S3 straight RPC-N 50 Ω male - RPC-TNC male,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

52.5<br />

SW20 SW14 SW14<br />

SW15<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

147


Series RPC-TNC<br />

xOrdering Number Version Remarks Return Loss<br />

x05 S 106-K00 S3 straight RPC-N 50 Ω male - RPC-TNC female ≥ 20 dB @ DC to 18 GHz<br />

53.6<br />

SW20<br />

SW14<br />

SW14<br />

x05 K 106-S00 S3 straight RPC-N 50 Ω female - RPC-TNC male ≥ 20 dB @ DC to 18 GHz<br />

46<br />

SW14<br />

SW14<br />

SW15<br />

x05 K 106-K00 S3 straight RPC-N 50 Ω female - RPC-TNC female ≥ 20 dB @ DC to 18 GHz<br />

x05 K 106-K20 S3 straight RPC-N 50 Ω female - RPC-TNC female,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 GHz to 18 GHz<br />

47.2<br />

SW14<br />

SW14<br />

148<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-TNC<br />

Tools<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

x06 W 021-000<br />

Remarks<br />

flat 15 mm - 55 Ncm torque for RPC-TNC<br />

152<br />

Gauge<br />

xOrdering Number<br />

x06 W 00S-000<br />

Remarks<br />

compatible to male connectors for RPC-TNC<br />

incl. gauge block<br />

1<br />

27.1<br />

ø11.8<br />

RPC-TNC<br />

x06 W 00K-000<br />

compatible to female connectors for RPC-TNC<br />

incl. gauge block<br />

29.5<br />

ø11.8<br />

SW15<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

149


<strong>Rosenberger</strong> RPC-7 precision connectors – with 7 mm outer<br />

diameter – have been designed for applications up to 18 GHz.<br />

RPC-7 connectors are “hermaphroditic” types mating electrically<br />

both centre and outer conductor by end-surface (butt) contact.<br />

The mechanical connection is designed as a counter-sinkable<br />

threaded socket.<br />

Die <strong>Rosenberger</strong>-Serie RPC-7 – Präzisionssteckverbinder<br />

mit 7 mm Außenleiter – wurde für Anwendungen im Frequenzbereich<br />

bis 18 GHz entwickelt. Die elektrische Verbindung<br />

erfolgt am Innen- wie auch am Außenleiter durch Stirnkontakt,<br />

die mechanische Verbindung wird durch eine versenkbare<br />

Gewindebuchse sichergestellt („Zwitter-Steckverbinder“)<br />

<strong>Rosenberger</strong> RPC-7 connectors are intermateable with<br />

other 7 mm connector series, e.g. APC-7, PC-7, GPC-7 or<br />

Precifix AA. RPC-7 and RPC-N connector heads are interchangeable<br />

using the same bead type.<br />

<strong>Rosenberger</strong> RPC-7-Steckverbinder sind steckkompatibel<br />

zu anderen 7 mm-Steckverbinder-Serien, z.B. APC-7,<br />

PC-7, GPC-7 oder Precifix AA. Die Steckverbinderköpfe von<br />

RPC-7 und RPC-N-Steckverbindern sind aufgrund gleicher<br />

Anschlussmaße auf der Montageseite austauschbar.<br />

The wide product range consists of connectors and connector<br />

heads, adapters, interchangeable port connectors, airlines as<br />

well as test & measurement accessories such as RPC-7 calibration<br />

and verification kits, test cables, attenuators or test devices<br />

(open – short – load).<br />

Das umfangreiche Produktspektrum umfasst Kabel-Steck-verbinder,<br />

Adapter, Wechselport, Luftleitungen, sowie Messzubehör<br />

wie RPC-7-Kalibrier- und Verifizier-Kits, <strong>Test</strong>kabel, Dämpfungsglieder<br />

oder <strong>Test</strong>-Komponenten (Open – Short – Load).


Series RPC-7<br />

RPC-7<br />

Features<br />

Interface according to IEC 457-2<br />

Frequency range DC to 18 GHz<br />

Return loss (connector head) ≥ 32 dB<br />

Impedance 50 Ω<br />

Threaded coupling, hermaphroditic<br />

Butted contact at inner and outer contact


Series RPC-7<br />

1Series RPC- 7<br />

Interface Dimensions Series RPC-7 (code 07)<br />

REFERENCE PLANE<br />

Referenzebene<br />

E<br />

A<br />

B<br />

C<br />

G<br />

D<br />

F<br />

Series RPC-7<br />

RPC-7<br />

dimension min. max.<br />

A 3.0397 nom.<br />

B 6.995 7.005<br />

C 14.850 14.860<br />

D 0.000 0.050<br />

E 1.060 1.085<br />

F 0.050 0.380<br />

G 11/16-24UNEF-2A<br />

152<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-7<br />

Technology<br />

Technical Data Series RPC-7<br />

Applicable standards | Anwendbare Standards<br />

Interface according to | Interface gemäß IEC 457-2<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (connector head) | Rückflußdämpfung (Steckerkopf)<br />

Insertion loss (connector head) | Dämpfung (Steckerkopf)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

50 Ω<br />

DC to 18 GHz<br />

≥ 32 dB, DC to 18 GHz<br />

≤ 0.03 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 1.0 mΩ<br />

≤ 0.1 mΩ<br />

2500 V rms<br />

1000 V rms<br />

≥ 120 dB up to 1 GHz<br />

Mating cycles | Steckzyklen ≥ 5000<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 28 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

1.36 Nm<br />

Coupling test torque | Prüfdrehmoment<br />

1.95 Nm<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen<br />

MIL-STD 202, Method 107, Condition B<br />

Corrosion resistance | Korrosionsbeständigkeit<br />

MIL-STD 202, Method 101, Condition B<br />

Vibration | Vibration<br />

MIL-STD 202, Method 204, Condition D<br />

Shock | Schock<br />

MIL-STD 202, Method 213, Condition I<br />

Moisture resistance | Feuchtigkeitsbeständigkeit MIL-STD 202, Method 106<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

RPC-7<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Beryllium copper, gold-plated<br />

PPE<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

153


Series RPC-7<br />

Connector Heads<br />

Connector Heads<br />

Straight Connector Head<br />

xOrdering Number Remarks Return Loss<br />

x07 P 121-000 S3 with bead ≥ 32 dB @ DC to 18 GHz<br />

22.2<br />

ø 22<br />

SW19<br />

Cable Connectors Semi-Rigid Cable<br />

Straight Connector, solder<br />

xOrdering Number Remarks Return Loss Cable<br />

Group<br />

Assembly<br />

Instruction<br />

x07 P 121-271 S3 a = 41.8 mm ≥ 26 dB @ DC to 18 GHz 71 02 A3<br />

x07 P 121-272 S3 a = 35 mm ≥ 26 dB @ DC to 18 GHz 72 02 A3<br />

x07 P 121-273 S3 a = 41.8 mm ≥ 26 dB @ DC to 18 GHz 73 03 A<br />

a<br />

Semi-Rigid<br />

ø 22<br />

SW19<br />

154<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-7<br />

Panel Connectors Coaxial End<br />

Panel Connectors Coaxial End<br />

Panel Connector, 4-hole flange<br />

Coaxial End<br />

xOrdering Number Return Loss Panel Piercing / PCB Layout<br />

x07 P 421-500 S3 ≥ 26 dB @ DC to 18 GHz MB 98<br />

43.5<br />

2<br />

15<br />

3<br />

ø 22<br />

ø 1.27<br />

ø 4.1<br />

SW19<br />

25.4<br />

18.2<br />

3.4<br />

x07 P 422-500 S3 ≥ 26 dB @ DC to 18 GHz MB 106a<br />

37.7<br />

2.2<br />

10<br />

ø 22<br />

ø 2.2<br />

Z<br />

SW19<br />

17.5<br />

12.7<br />

Z<br />

ø 0.67<br />

ø 2.2<br />

RPC-7<br />

2.5<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

155


Series RPC-7<br />

Adaptors<br />

Adaptors<br />

Adaptor (In Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x07 P 121-P00 S3 straight RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

50.4<br />

SW19<br />

SW10<br />

SW19<br />

Adaptor (Inter Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x02 KR 107-P00 S3 straight RPC-2.92 female, ruggedized - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

45.2<br />

ø 22<br />

x03 S 107-P00 S3 straight RPC-3.50 male - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

x03 S 107-P20 S3 straight RPC-3.50 male - RPC-7,<br />

calibration adaptor<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 28 dB @ 4 GHz to 18 GHz<br />

SW19<br />

SW19<br />

38.8<br />

ø 15.7<br />

ø 22<br />

SW8<br />

SW14<br />

SW19<br />

x03 K 107-P00 S3 straight RPC-3.50 female - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

x03 K 107-P20 S3 straight RPC-3.50 female - RPC-7,<br />

calibration adaptor<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 28 dB @ 4 GHz to 18 GHz<br />

36.8<br />

ø 16<br />

ø 22<br />

SW13<br />

SW19<br />

x03 KR 107-P00 S3 straight RPC-3.50 female, ruggedized - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

45.2<br />

ø 22<br />

SW19<br />

SW19<br />

x05 S 107-P00 S3 straight RPC-N 50 Ω male - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

45<br />

ø 22<br />

SW20<br />

SW14<br />

SW19<br />

x05 K 107-P00 S3 straight RPC-N 50 Ω female - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

38.6<br />

ø 22<br />

SW14<br />

SW19<br />

156<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-7<br />

xOrdering Number Version Remarks Return Loss<br />

x06 S 107-P20 S3 straight RPC-TNC male - RPC-7,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 to 18 GHz<br />

43<br />

ø 22<br />

SW15<br />

SW13<br />

SW19<br />

x06 K 107-P20 S3 straight RPC-TNC female - RPC-7,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 20 dB @ 4 to 18 GHz<br />

53<br />

ø 22<br />

SW13<br />

SW19<br />

x07 P 151-S00 S3 straight RPC-7 - BNC 50 Ω male ≥ 22 dB @ DC to 4 GHz<br />

42.9<br />

ø 22<br />

SW19<br />

SW13<br />

x07 P 151-K00 S3 straight RPC-7 - BNC 50 Ω female ≥ 22 dB @ DC to 4 GHz<br />

39.1<br />

ø 22<br />

x07 P 110-S20 S3 straight RPC-7 - RPC-SP male,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 18 GHz<br />

SW19<br />

46.8<br />

SW13<br />

RPC-7<br />

ø 22<br />

SW19<br />

x07 P 110-K20 S3 straight RPC-7 - RPC-SP female,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 18 GHz<br />

48.2<br />

ø 22<br />

SW19<br />

SW19<br />

x07 P 132-S00 S3 straight RPC-7 - SMA male ≥ 23 dB @ DC to 18 GHz<br />

38.7<br />

ø 22<br />

ø 15.7<br />

SW19<br />

SW14<br />

SW8<br />

x07 P 132-K00 S3 straight RPC-7 - SMA female ≥ 23 dB @ DC to 18 GHz<br />

37.4<br />

ø 22<br />

ø 15.7<br />

SW19<br />

SW13<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

157


Series RPC-7<br />

Interchangeable Port Connector System<br />

Interchangeable Port Connector System<br />

RPC-7 - RPC-SL 26.5 GHz<br />

xOrdering Number Version Remarks Return Loss<br />

x07 P 104-S00 S3 straight RPC-7 - RPC-SL 26.5 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz 1<br />

41.6<br />

SW19<br />

SW14<br />

SW18<br />

RPC-7 - RPC-SL 40 GHz<br />

xOrdering Number Version Remarks Return Loss<br />

x07 P 1P4-S00 S3 straight RPC-7 - RPC-SL 40 GHz male,<br />

max. Frequency 18 GHz<br />

≥ 21 dB @ DC to 18 GHz 1<br />

41.6<br />

SW19<br />

SW14 SW18<br />

see also chapter interchangeable port connector system<br />

158<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-7<br />

Tools<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

x07 W 021-000<br />

Remarks<br />

flat 19 mm - 136 Ncm torque for RPC 7, RPC-SP<br />

157<br />

Collet Extractor<br />

xOrdering Number<br />

x07 W 031-000<br />

for RPC-7, to remove 7 mm center contact<br />

91.7<br />

Gauge<br />

xOrdering Number<br />

x07 W 001-000<br />

compatible to connectors for RPC-7<br />

incl. gauge block<br />

25<br />

RPC-7<br />

ø14<br />

SW19<br />

Accessories<br />

Accessories<br />

Bead<br />

xOrdering Number Remarks Return Loss<br />

x07 B 003-000 7 mm, 50 Ω ≥ 54 dB @ DC to 2 GHz<br />

≥ 37 dB @ 2 GHz to 18 GHz<br />

x07 B 003-010 7 mm, 50 Ω ≥ 54 dB @ DC to 2 GHz<br />

≥ 40 dB @ 2 GHz to 18 GHz<br />

ø 9.38<br />

2.97<br />

extended scale<br />

Center Contact<br />

xOrdering Number<br />

x07 P 121-000/21<br />

Remarks<br />

changeable center conductor<br />

3.8<br />

extended scale<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

159


Series R<br />

RPC-SP connectors are 50 Ω precision connectors with an outer<br />

contact diameter of 4.10 mm for applications up to 22 GHz. RPC-SP<br />

precision connectors are intermateable with OSP and BMA<br />

connectors.<br />

Die Serie RPC-SP ist eine 50 Ω-Präzisionssteckverbinderse<br />

rie mit 4.10 mm Außenleiterdurchmesser für Anwendungen<br />

bis 22 GHz. RPC-SP-Steckverbinder sind steckkompatibel<br />

zu OSP- und BMA-Steckverbindern.<br />

RPC-SP connectors are indicated for applications where quick and<br />

reliable interconnects are required, as well as for applications with<br />

racks and plug-in units. The floating construction allows compensation<br />

of axial and radial misalignment. Tightening the connection<br />

requires no additional tooling, so that RPC-SP-connectors are<br />

ideally suited for application with tight space requirements.<br />

Die Serie wurde entwickelt für Anwendungen, die zuverlässiges<br />

und wiederholtes Verbinden mit gleichzeitigem axialen und<br />

radialen Toleranzausgleich erfordern („Blind-Mate-Verbindungen“).<br />

Da zum Verriegeln der Verbindung kein Werkzeug<br />

benötigt wird (z.B. Drehmomentschlüssel), eignen sich RPC-<br />

SP-Steckverbinder für Anwendungen auf engstem Raum.<br />

The product range consists of cable, panel and PCB connectors,<br />

adapters to other coaxial connector series, airlines as well as test &<br />

measurement accessories such as RPC-SP calibration kits, test<br />

cables or test devices (open – short – load).<br />

Das Produktspektrum umfasst Kabel-, Gehäuse- und<br />

Leiterplattensteckverbinder, Adapter auf andere Koaxial-<br />

Steckverbinderserien, Luftleitungen, sowie Messzubehör<br />

wie RPC-7-Kalibrier-Kits, <strong>Test</strong>kabel oder <strong>Test</strong>-Komponenten<br />

(Open – Short – Load).


Series RPC-SP<br />

PC-SP<br />

Features<br />

Interface according to IEC 61169-33<br />

Frequency range DC to 22 GHz<br />

Return loss (cable connector) ≥ 26 dB<br />

Impedance 50 Ω<br />

Blind mate connection<br />

Intermateable with OSP and BMA<br />

RPC-SP


Series RPC-SP<br />

1Series RPC- SP<br />

Interface Dimensions Series RPC-SP (code 10)<br />

REFERENCE PLANE<br />

Referenzebene<br />

REFERENCE PLANE<br />

Referenzebene<br />

D<br />

D<br />

A<br />

E<br />

B<br />

C<br />

C<br />

B<br />

A<br />

MALE<br />

Stecker<br />

FEMALE<br />

Kuppler<br />

Series RPC-SP<br />

Male | Stecker<br />

Female | Kuppler<br />

dimension min. max. min. max.<br />

A 1.77 1.79 1.77 1.79<br />

B 4.09 4.11 4.07<br />

C 5.30 5.35 5.50<br />

D 3.25 3.35 3.12 3.22<br />

E 0.90 0.93 1.77 1.79<br />

162<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-SP<br />

Technology<br />

Technical Data Series RPC-SP<br />

Applicable standards | Anwendbare Standards<br />

Interface according to | Interface gemäß<br />

Mechanically compatible with | Mechanisch kompatibel mit<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (cable connector) | Rückflußdämpfung (Kabelsteckverbinder)<br />

Insertion loss (cable connector) | Dämpfung (Kabelsteckverbinder)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

IEC 61169-33; MIL-STD 348A<br />

OSP and BMA<br />

50 Ω<br />

DC to 22 GHz<br />

≥ 26 dB, DC to 22 GHz<br />

≤ 0.03 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 2.0 mΩ<br />

≤ 2.0 mΩ<br />

1000 V rms<br />

400 V rms<br />

≥ 85 dB up to 1 GHz<br />

Mating cycles | Steckzyklen ≥ 1000<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 27 N<br />

Engagement force | Einsteckkraft<br />

≤ 13.5 N<br />

Disengagement force | Ausziehkraft<br />

≥ 2.0 N<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen<br />

MIL-STD 202, Method 107, Condition B<br />

Corrosion resistance | Korrosionsbeständigkeit<br />

MIL-STD 202, Method 101, Condition B<br />

Vibration | Vibration<br />

MIL-STD 202, Method 204, Condition D<br />

Shock | Schock<br />

MIL-STD 202, Method 213, Condition I<br />

Moisture resistance | Feuchtigkeitsbeständigkeit MIL-STD 202, Method 106<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

RPC-SP<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Stainless steel, passivated<br />

PS, PTFE<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

163


Series RPC-SP<br />

Cable Connectors Semi- Rigid Cable<br />

Cable Connectors Semi-Rigid Cable<br />

Straight Plug, solder<br />

xOrdering Number Remarks Return Loss Cable<br />

Group<br />

Assembly<br />

Instruction<br />

x10 S 125-271 S3 applicable to MIL C 38 999 shell ≥ 21 dB @ DC to 22 GHz 71 02 A3<br />

x10 S 125-272 S3 applicable to MIL C 38 999 shell ≥ 21 dB @ DC to 22 GHz 72 03 A<br />

24.1<br />

Semi-Rigid<br />

SW6.35<br />

SW6<br />

Panel Plug, hexagonal flange<br />

xOrdering Number Return Loss Cable Group Assembly<br />

Instruction<br />

x10 S 641-271 E3 ≥ 23 dB @ DC to 22 GHz 71 02 A3 MB 92<br />

x10 S 641-272 E3 ≥ 23 dB @ DC to 22 GHz 72 03 A MB 92<br />

Panel Piercing /<br />

PCB Layout<br />

20<br />

Semi-Rigid<br />

SW8 SW11 SW8<br />

Panel Jack, 2-hole flange<br />

xOrdering Number Return Loss Cable Group Assembly<br />

Instruction<br />

x10 K 762-271 N3 ≥ 21 dB @ DC to 22 GHz 71 10 E MB 100<br />

x10 K 762-272 N3 ≥ 21 dB @ DC to 22 GHz 72 10 E MB 100<br />

Panel Piercing /<br />

PCB Layout<br />

18.3<br />

Semi-Rigid<br />

ø 19<br />

ø 9.5<br />

164<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-SP<br />

Panel Connectors Coaxial End / PCB Connectors<br />

Panel Connectors Coaxial End<br />

Panel Jack, 4-hole flange<br />

xOrdering Number Return Loss Panel Piercing / PCB Layout<br />

x10 S 441-500 N3 ≥ 21 dB @ DC to 22 GHz MB 55a<br />

1.6<br />

24.9<br />

10 5<br />

Coaxial End<br />

12.7<br />

ø 6.4<br />

ø 1.3<br />

ø 4.1<br />

PCB Connectors SMD<br />

Straight Plug<br />

xOrdering Number Remarks Return Loss Panel Piercing / PCB Layout<br />

SMD<br />

x10 S 101-40M T3 tape & reel, VG 07.50000 ≥ 25 dB @ DC to 18 GHz<br />

≥ 21 dB @ 18 GHz to 22 GHz<br />

on request<br />

7.4<br />

5.7<br />

1.3<br />

10.8<br />

4.7<br />

1.7<br />

3.4<br />

6.5<br />

PCB Connectors Solder Pin<br />

Straight Plug<br />

xOrdering Number Remarks Return Loss Panel Piercing / PCB Layout<br />

Solder Pin<br />

x10 S 142-400 E3 blister ≥ 30 dB @ DC to 3 GHz<br />

≥ 28 dB @ 3 to 6 GHz<br />

on request<br />

11.2<br />

6.35<br />

RPC-SP<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

165


Series RPC-SP<br />

Adaptors<br />

Adaptors<br />

Adaptor (Inter Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x03 S 110-S01 S3 straight RPC-3.50 male - RPC-SP male ≥ 23 dB @ DC to 22 GHz<br />

x03 S 110-S21 S3 straight RPC-3.50 male - RPC-SP male,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 22 GHz<br />

23.8<br />

ø 11.6<br />

ø 13.9<br />

SW5.5<br />

SW12<br />

x03 S 110-K01 S3 straight RPC-3.50 male - RPC-SP female ≥ 23 dB @ DC to 22 GHz<br />

x03 S 110-K21 S3 straight RPC-3.50 male - RPC-SP female,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 22 GHz<br />

ø 11.6<br />

28.3<br />

ø 13.9<br />

SW5.5 SW12<br />

x03 K 110-S01 S3 straight RPC-3.50 female - RPC-SP male ≥ 23 dB @ DC to 22 GHz<br />

x03 K 110-S21 S3 straight RPC-3.50 female - RPC-SP male,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 22 GHz<br />

22.7<br />

ø 11.6<br />

ø 13.9<br />

SW5.5<br />

SW12<br />

x03 K 110-K01 S3 straight RPC-3.50 female - RPC-SP female ≥ 23 dB @ DC to 22 GHz<br />

x03 K 110-K21 S3 straight RPC-3.50 female - RPC-SP female,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 22 GHz<br />

27.3<br />

ø 11.6<br />

ø 13.9<br />

SW5.5<br />

SW12<br />

x07 P 110-S20 S3 straight RPC-7 - RPC-SP male,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 18 GHz<br />

46.8<br />

ø 22<br />

SW19<br />

x07 P 110-K20 S3 straight RPC-7 - RPC-SP female,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 18 GHz<br />

48.2<br />

ø 22<br />

SW19<br />

SW19<br />

166<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-SP<br />

Tools / Accessories<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

x07 W 021-000<br />

Remarks<br />

flat 19 mm - 136 Ncm torque for RPC 7, RPC-SP<br />

157<br />

Accessories<br />

Coupling Nut<br />

xOrdering Number<br />

x10 Z 001-S00 S<br />

Remarks<br />

male, stainless steel<br />

16.9<br />

x10 Z 001-K00 S<br />

female, stainless steel<br />

18<br />

RPC-SP<br />

ø 22<br />

SW19<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

167


<strong>Rosenberger</strong> RPC-3.50 connectors – 50 Ω precision connectors<br />

with an outer diameter of 3.50 mm and air dielectric –<br />

are featured by excellent technical data over the full frequency range<br />

up to 26.5 GHz. They are intermateable with APC-3.50, GPC-3.50,<br />

SMA, K and RPC-2.92 connectors.<br />

<strong>Rosenberger</strong> RPC-3.50 Steckverbinder – 50 Ω-Präzisionssteckverbinder<br />

mit 3.50 mm Außenleiterdurchmesser –<br />

bieten aufgrund des Luft-Dielektrikums hervorragende<br />

Eigenschaften über den gesamten Frequenzbereich bis 26.5 GHz.<br />

Sie sind steckkompatibel zu APC-3.50-, GPC-3.50-, SMA-,<br />

K-, und RPC-2.92-Steckverbindern.<br />

<strong>Rosenberger</strong> offers a wide range of RPC-3.50 cable and panel<br />

connectors, adaptors, interchangeable port connectors, attenuators<br />

as well as test & measurement accessories such as RPC-3.50<br />

calibration kits, test cables or test devices, e.g. opens, shorts, loads,<br />

attenuators, airlines, sliding loads.<br />

Das Produktspektrum umfasst Kabel- und Gehäuse-Steckverbinder,<br />

Adapter, Wechselport-Steckverbinder, Dämpfungsglieder<br />

sowie Messzubehör wie RPC-3.50-Kalibrier-Kits,<br />

<strong>Test</strong>kabel oder <strong>Test</strong>zubehör, z. B. Opens, Shorts, Loads,<br />

Dämpfungsglieder, Luftleitungen oder Sliding Loads.


Series RPC-3.50<br />

Features<br />

Interface according to 60169-23<br />

Frequency range DC to 26.5 GHz<br />

Return loss (connector head) ≥ 30 dB<br />

Impedance 50 Ω<br />

Threaded coupling<br />

Intermateable with K-, SMA and RPC-2.92<br />

RPC-3.50


Series RPC-3.50<br />

1Series RPC- 3.50<br />

Interface Dimensions Series RPC-3.50 (code 03)<br />

D<br />

REFERENCE PLANE<br />

Referenzebene<br />

REFERENCE PLANE<br />

Referenzebene<br />

D<br />

A<br />

E<br />

B<br />

C<br />

F<br />

F<br />

C<br />

B<br />

E<br />

A<br />

MALE<br />

Stecker<br />

FEMALE<br />

Kuppler<br />

Series RPC-3.50<br />

Male | Stecker<br />

Female | Kuppler<br />

dimension min. max. min. max.<br />

A 1.51 1.53 1.51 1.53<br />

B 3.49 3.51 3.49 3.51<br />

C 4.57 4.59 4.63 4.65<br />

D 0.00 0.08 0.00 0.08<br />

E 0.91 0.93 0.96 0.98<br />

F 1/4-36UNS-2B 1/4-36UNS-2A<br />

170<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-3.50<br />

Technology<br />

Technical Data Series RPC-3.50<br />

Applicable standards | Anwendbare Standards<br />

Interface according to | Interface gemäß IEC 60169-23<br />

Mechanically compatible with | Mechanisch kompatibel mit<br />

RPC-2.92 and SMA<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (connector head) | Rückflußdämpfung (Steckerkopf)<br />

Insertion loss (connector head) | Dämpfung (Steckerkopf)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

50 Ω<br />

DC to 26.5 GHz<br />

≥ 30 dB, DC to 26.5 GHz<br />

≤ 0.03 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 3.0 mΩ<br />

≤ 2.0 mΩ<br />

1000 V rms<br />

335 V rms<br />

≥ 100 dB up to 1 GHz<br />

Mating cycles | Steckzyklen ≥ 500<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 27 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

0.80 Nm to 1.10 Nm<br />

Coupling test torque | Prüfdrehmoment<br />

1.70 Nm<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen<br />

MIL-STD 202, Method 107, Condition B<br />

Corrosion resistance | Korrosionsbeständigkeit<br />

MIL-STD 202, Method 101, Condition B<br />

Vibration | Vibration<br />

MIL-STD 202, Method 204, Condition D<br />

Shock | Schock<br />

MIL-STD 202, Method 213, Condition I<br />

Moisture resistance | Feuchtigkeitsbeständigkeit MIL-STD 202, Method 106<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

Gasket | Dichtung<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Stainless steel, passivated<br />

PS<br />

Silicone<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

RPC-3.50<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

171


Series RPC-3.50<br />

Connector Heads<br />

Connector Heads<br />

Straight Plug<br />

xOrdering Number Remarks Return Loss<br />

x03 S 121-000 S3 with bead ≥ 30 dB @ DC to 26.5 GHz<br />

19.9<br />

ø 9<br />

SW8<br />

SW8<br />

Straight Jack<br />

xOrdering Number Remarks Return Loss<br />

x03 K 121-000 S3 with bead ≥ 30 dB @ DC to 26.5 GHz<br />

19.1<br />

ø 9<br />

SW8<br />

172<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-3.50<br />

Cable Connectors Semi- Rigid Cable / Panel Connectors Stripline<br />

Cable Connectors Semi-Rigid Cable<br />

Straight Plug, solder<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x03 S 121-271 S3 ≥ 25 dB @ DC to 26.5 GHz 71 02 A3<br />

x03 S 121-272 S3 ≥ 25 dB @ DC to 26.5 GHz 72 03 A<br />

35.6<br />

Semi-Rigid<br />

ø 10<br />

SW8 SW8 SW9 SW8<br />

Straight Jack, solder<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x03 K 121-271 S3 ≥ 25 dB @ DC to 26.5 GHz 71 02 A3<br />

x03 K 121-272 S3 ≥ 25 dB @ DC to 26.5 GHz 72 03 A<br />

35<br />

Semi-Rigid<br />

ø 10<br />

SW8 SW9 SW8<br />

Panel Jack, 4-hole flange<br />

xOrdering Number Return Loss Cable<br />

Group<br />

Assembly<br />

Instruction<br />

x03 K 421-271 S3 ≥ 25 dB @ DC to 26.5 GHz 71 02 A3 MB 55<br />

Panel Piercing /<br />

PCB Layout<br />

34.7<br />

Semi-Rigid<br />

ø 10<br />

SW9<br />

SW8<br />

Panel Connectors Stripline<br />

Panel Jack, 4-hole flange<br />

xOrdering Number Remarks Return Loss Panel Piercing / PCB Layout<br />

x03 K 421-600 S3 stripline ≥ 23 dB @ DC to 26.5 GHz MB 55d<br />

10.7<br />

0.1<br />

Stripline<br />

RPC-3.50<br />

12.7<br />

8.6<br />

max. 1.2<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

173


Series RPC-3.50<br />

Adaptors<br />

Adaptors<br />

Adaptor (In Series)<br />

xOrdering Number Version Remarks Return Loss Panel Piercing /<br />

PCB Layout<br />

x03 S 121-S00 S3 straight RPC-3.50 male - male ≥ 26 dB @ DC to 26.5 GHz<br />

x03 S 121-S20 S3 straight RPC-3.50 male - male,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 26.5 GHz<br />

30.7<br />

x03 S 121-K00 S3 straight RPC-3.50 male - female ≥ 26 dB @ DC to 26.5 GHz<br />

x03 S 121-K20 S3 straight RPC-3.50 male - female,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 26.5 GHz<br />

29.7<br />

x03 K 121-K00 S3 straight RPC-3.50 female - female ≥ 26 dB @ DC to 26.5 GHz<br />

x03 K 121-K20 S3 straight RPC-3.50 female - female,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 30 dB @ 4 GHz to 26.5 GHz<br />

28.5<br />

x03 S 422-S00 S3 straight RPC-3.50 malemale<br />

ruggedized,<br />

4-hole flange<br />

≥ 20 dB @ DC to 26.5 GHz<br />

63.4<br />

36<br />

SW8<br />

SW12<br />

SW12<br />

SW19<br />

x03 K 521-S00 S3 straight RPC-3.50 female - male,<br />

round flange<br />

≥ 26 dB @ DC to 26.5 GHz MB 107<br />

36.2<br />

SW17<br />

SW8 SW14<br />

SW8<br />

x03 K 721-S23 S3 straight RPC-3.50 female - male,<br />

2-hole flange,<br />

floating test adaptor<br />

≥ 26 dB @ DC to 18 GHz<br />

≥ 23 dB @ 18 GHz to 26.5 GHz<br />

26.6<br />

ø 20<br />

SW8<br />

SW8<br />

x03 KR 121-S00 S3 straight RPC-3.50<br />

female ruggedized -<br />

male<br />

≥ 26 dB @ DC to 26.5 GHz<br />

35.8<br />

ø 22<br />

SW19<br />

SW8<br />

SW8<br />

x03 KR 121-K00 S3 straight RPC-3.50<br />

female ruggedized -<br />

female<br />

≥ 26 dB @ DC to 26.5 GHz<br />

34.8<br />

ø 22<br />

SW19<br />

SW8<br />

174<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-3.50<br />

Adaptor (Inter Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x03 S 159-S20 S3 straight RPC-3.50 male - FAKRA male,<br />

calibration adaptor<br />

≥ 38 dB @ DC to 1 GHz<br />

≥ 26 dB @ 1 to 3 GHz<br />

≥ 21 dB @ 3 to 6 GHz<br />

53.5<br />

ø 9<br />

SW8<br />

SW8<br />

x03 S 159-K20 S3 straight RPC-3.50 male - FAKRA female,<br />

calibration adaptor<br />

≥ 38 dB @ DC to 1 GHz<br />

≥ 26 dB @ 1 to 3 GHz<br />

≥ 21 dB @ 3 to 6 GHz<br />

47.4<br />

ø 9<br />

SW8<br />

SW8<br />

x03 K 159-S20 S3 straight RPC-3.50 female - FAKRA male,<br />

calibration adaptor<br />

≥ 38 dB @ DC to 1 GHz<br />

≥ 26 dB @ 1 to 3 GHz<br />

≥ 21 dB @ 3 to 6 GHz<br />

52.6<br />

ø 9<br />

SW8<br />

x03 K 159-K20 S3 straight RPC-3.50 female - FAKRA female,<br />

calibration adaptor<br />

≥ 38 dB @ DC to 1 GHz<br />

≥ 26 dB @ 1 to 3 GHz<br />

≥ 21 dB @ 3 to 6 GHz<br />

46.5<br />

ø 9<br />

SW8<br />

x03 S 128-S20 N3 straight RPC-3.50 male - QMA male,<br />

calibration adaptor<br />

≥ 32 dB @ DC to 4 GHz<br />

≥ 24 dB @ 4 GHz to 18 GHz<br />

33.5<br />

SW8<br />

SW8<br />

x03 S 128-K20 N3 straight RPC-3.50 male - QMA female,<br />

calibration adaptor<br />

≥ 32 dB @ DC to 4 GHz<br />

≥ 24 dB @ 4 GHz to 18 GHz<br />

24.5<br />

ø 9<br />

SW8<br />

SW8<br />

x03 K 128-S20 N3 straight RPC-3.50 female - QMA male,<br />

calibration adaptor<br />

≥ 32 dB @ DC to 4 GHz<br />

≥ 24 dB @ 4 GHz to 18 GHz<br />

32.3<br />

ø 9<br />

SW8<br />

RPC-3.50<br />

x03 K 128-K20 N3 straight RPC-3.50 female - QMA female,<br />

calibration adaptor<br />

≥ 32 dB @ DC to 4 GHz<br />

≥ 24 dB @ 4 GHz to 18 GHz<br />

23.4<br />

ø 9<br />

SW8<br />

x03 K 728-S22 S3 straight RPC-3.50 female - QMA male,<br />

2-hole flange,<br />

floating test adaptor<br />

≥ 40 dB @ DC to 2.5 GHz<br />

≥ 28 dB @ 2.5 GHz to 6 GHz<br />

≥ 24 dB @ 6 GHz to 18 GHz<br />

28.4<br />

ø 20<br />

ø 10.5<br />

ø 10<br />

x03 S 109-S00 S3 straight RPC-3.50 male - RPC 2.40 male ≥ 23 dB @ DC to 26.5 GHz<br />

35.3<br />

ø 9<br />

SW8<br />

SW8<br />

SW8 SW8<br />

x03 S 109-K00 S3 straight RPC-3.50 male - RPC 2.40 female ≥ 23 dB @ DC to 26.5 GHz<br />

32.2<br />

ø 9<br />

SW8 SW8 SW8<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

175


Series RPC-3.50<br />

xOrdering Number Version Remarks Return Loss<br />

x03 K 109-S00 S3 straight RPC-3.50 female - RPC 2.40 male ≥ 23 dB @ DC to 26.5 GHz<br />

34.6<br />

ø 9<br />

SW8 SW8 SW8<br />

x03 K 109-K00 S3 straight RPC-3.50 female - RPC 2.40 female ≥ 23 dB @ DC to 26.5 GHz<br />

31.1<br />

ø 9<br />

SW8<br />

SW8<br />

x03 S 105-S00 S3 straight RPC-3.50 male - RPC-N 50 Ω male ≥ 26 dB @ DC to 18 GHz<br />

45<br />

ø 15.7<br />

ø 19<br />

SW8<br />

SW14<br />

SW20<br />

x03 S 105-K00 S3 straight RPC-3.50 male - RPC-N 50 Ω female ≥ 26 dB @ DC to 18 GHz<br />

43.8<br />

ø 15.7<br />

SW8 SW14 SW14<br />

x03 K 105-S00 S3 straight RPC-3.50 female - RPC-N 50 Ω male ≥ 26 dB @ DC to 18 GHz<br />

43.1<br />

ø 16<br />

ø 15.7<br />

SW13<br />

SW14<br />

SW20<br />

x03 K 105-K00 S3 straight RPC-3.50 female - RPC-N 50 Ω female ≥ 26 dB @ DC to 18 GHz<br />

41.8<br />

ø 15.7<br />

SW13<br />

SW14<br />

x03 KR 105-K00 S3 straight RPC-3.50 female, ruggedized -<br />

RPC-N 50 Ω female<br />

≥ 26 dB @ DC to 18 GHz<br />

43.8<br />

ø 22<br />

ø 15.7<br />

SW19<br />

SW14<br />

x03 KR 105-S00 S3 straight RPC-3.50 female, ruggedized -<br />

RPC-N 50 Ω male<br />

≥ 26 dB @ DC to 18 GHz<br />

44.8<br />

ø 22<br />

SW19<br />

SW20<br />

x03 S 107-P00 S3 straight RPC-3.50 male - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

x03 S 107-P20 S3 straight RPC-3.50 male - RPC-7,<br />

calibration adaptor<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 28 dB @ 4 GHz to 18 GHz<br />

38.8<br />

ø 15.7<br />

ø 22<br />

SW8<br />

SW14<br />

SW19<br />

176<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-3.50<br />

xOrdering Number Version Remarks Return Loss<br />

x03 K 107-P00 S3 straight RPC-3.50 female - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

x03 K 107-P20 S3 straight RPC-3.50 female - RPC-7,<br />

calibration adaptor<br />

≥ 36 dB @ DC to 4 GHz<br />

≥ 28 dB @ 4 GHz to 18 GHz<br />

36.8<br />

ø 16<br />

ø 22<br />

SW13<br />

SW19<br />

x03 KR 107-P00 S3 straight RPC-3.50 female, ruggedized - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

45.2<br />

ø 22<br />

SW19<br />

SW19<br />

x03 S 110-S01 S3 straight RPC-3.50 male - RPC-SP male ≥ 23 dB @ DC to 22 GHz<br />

x03 S 110-S21 S3 straight RPC-3.50 male - RPC-SP male,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 22 GHz<br />

23.8<br />

ø 11.6<br />

ø 13.9<br />

SW5.5<br />

SW12<br />

x03 S 110-K01 S3 straight RPC-3.50 male - RPC-SP female ≥ 23 dB @ DC to 22 GHz<br />

x03 S 110-K21 S3 straight RPC-3.50 male - RPC-SP female,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 22 GHz<br />

ø 11.6<br />

28.3<br />

ø 13.9<br />

SW5.5 SW12<br />

x03 K 110-S01 S3 straight RPC-3.50 female - RPC-SP male ≥ 23 dB @ DC to 22 GHz<br />

x03 K 110-S21 S3 straight RPC-3.50 female - RPC-SP male,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 22 GHz<br />

22.7<br />

ø 11.6<br />

ø 13.9<br />

SW5.5<br />

SW12<br />

x03 K 110-K01 S3 straight RPC-3.50 female - RPC-SP female ≥ 23 dB @ DC to 22 GHz<br />

x03 K 110-K21 S3 straight RPC-3.50 female - RPC-SP female,<br />

calibration adaptor<br />

≥ 34 dB @ DC to 4 GHz<br />

≥ 26 dB @ 4 GHz to 22 GHz<br />

27.3<br />

ø 11.6<br />

ø 13.9<br />

x03 K 706-S23 S3 straight RPC-3.50 female - RPC-TNC male,<br />

2-hole flange,<br />

floating test adaptor<br />

≥ 35 dB @ DC to 2.5 GHz<br />

≥ 25 dB @ 2.5 GHz to 6 GHz<br />

≥ 20 dB @ 6 GHz to 16 GHz<br />

≥ 17 dB @ 16 GHz to 18 GHz<br />

SW5.5<br />

SW12<br />

43.5<br />

RPC-3.50<br />

ø 20.7<br />

ø 32<br />

SW16<br />

SW15<br />

x03 K 719-S22 S3 straight RPC-3.50 female - SMP male,<br />

full detent, 2-hole flange,<br />

floating test adaptor<br />

≥ 30 dB @ DC to 12 GHz<br />

≥ 20 dB @ 12 to 26.5 GHz<br />

24.7<br />

ø 20<br />

SW8<br />

SW6<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

177


Series RPC-3.50<br />

Interchangeable Port Connector System<br />

Interchangeable Port Connector System<br />

RPC-3.50 - RPC-SL 26.5 GHz<br />

xOrdering Number Version Remarks Return Loss<br />

x03 S 104-S00 S3 straight RPC-3.50 male - RPC-SL 26.5 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

29.2<br />

ø 18.5<br />

SW18<br />

x03 K 104-S00 S3 straight RPC-3.50 female - RPC-SL 26.5 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

28<br />

ø 19<br />

SW14<br />

SW18<br />

see also chapter interchangeable port connector system<br />

178<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-3.50<br />

Tools<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

x03 W 021-000<br />

Remarks<br />

flat 8 mm - 0.9 Nm torque for RPC-3.50 , RPC- 2.92, RPC-2.40, RPC-1.85<br />

136.5<br />

Gauge<br />

xOrdering Number<br />

x03 W 00S-000<br />

Remarks<br />

compatible to male connectors for RPC-3.50, RPC-2.92<br />

incl. gauge block<br />

ø15<br />

x03 W 00K-000<br />

compatible to female connectors for RPC-3.50, RPC-2.92<br />

incl. gauge block<br />

RPC-3.50<br />

30<br />

33<br />

ø15<br />

SW8<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

179


RPC-2.92 precision connectors from <strong>Rosenberger</strong> with 50 Ω impedance<br />

and an outer diameter of 2.92 mm are applicable for test<br />

& measurement applications up to 40 GHz.<br />

RPC-2.92-Steckverbinder von <strong>Rosenberger</strong> sind 50 Ω-Präzisionssteckverbinder<br />

mit 2.92 mm Außenleiter für Messtechnik-<br />

Anwendungen bis 40 GHz.<br />

Due to the shortened male pin and the fourfold slotted female<br />

center contact, RPC-2.92 connectors meet highest levels of<br />

reliability and repeatability of performance.<br />

RPC-2.92 connectors are intermateable with APC-3.50,<br />

GPC-3.50, SMA, as well as K connectors.<br />

Aufgrund eines verkürzten Steckerstiftes und einer 4-fach<br />

geschlitzten Innenleiterbuchse zeichnet sich die Steckverbinder-Serie<br />

RPC-2.92 durch sehr hohe Zuverlässigkeit sowie<br />

eine hervorragende Reproduzierbarkeit aus.<br />

RPC-2.92 Steckverbinder sind steckkompatibel zu<br />

APC-3.50-, GPC-3.50-, SMA-, sowie K-Steckverbindern.<br />

The wide product spectrum consists of cable, PCB and panel<br />

connectors, adaptors, interchangeable port connectors,<br />

attenuators as well as test & measurement accessories such as<br />

RPC-2.92 calibration kits, test cables, opens, shorts, loads,<br />

attenuators, airlines or sliding loads.<br />

Das Produktspektrum umfasst Kabel-, Leiterplatten- und Gehäuse-Steckverbinder,<br />

Adapter, Wechselport-Steckverbinder,<br />

Dämpfungsglieder sowie Messzubehör wie RPC-2.92-Kalibrier-<br />

Kits, <strong>Test</strong>kabel, Opens, Shorts, Loads, Dämpfungsglieder,<br />

Luftleitungen oder Sliding Loads.


Series RPC-2.92<br />

Features<br />

Frequency range DC to 40 GHz<br />

Return loss (connector head) ≥ 23 dB<br />

Impedance 50 Ω<br />

Threaded coupling<br />

Intermateable with K-, SMA- and RPC-3.50 mm connectors<br />

RPC-2.92


Series RPC-2.92<br />

1Series RPC- 2.92<br />

Interface Dimensions Series RPC-2.92 (code 02)<br />

D<br />

REFERENCE PLANE<br />

Referenzebene<br />

REFERENCE PLANE<br />

Referenzebene<br />

D<br />

A<br />

E<br />

B<br />

C<br />

F<br />

F<br />

C<br />

B<br />

E<br />

A<br />

MALE<br />

Stecker<br />

FEMALE<br />

Kuppler<br />

Series RPC-2.92<br />

Male | Stecker<br />

Female | Kuppler<br />

dimension min. max. min. max.<br />

A 1.26 1.28 1.26 1.28<br />

B 2.91 2.93 2.91 2.93<br />

C 4.57 4.59 4.62 4.65<br />

D 0.00 0.08 0.00 0.08<br />

E 0.91 0.93 0.96 0.98<br />

F 1/4-36UNS-2B 1/4-36UNS-2A<br />

182<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-2.92<br />

Technology<br />

Technical Data Series RPC-2.92<br />

Applicable standards | Anwendbare Standards<br />

Mechanically compatible with | Mechanisch kompatibel mit<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (connector head) | Rückflußdämpfung (Steckerkopf)<br />

Insertion loss (connector head) | Dämpfung (Steckerkopf)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

RPC-3.50 and SMA<br />

50 Ω<br />

DC to 40 GHz<br />

≥ 23 dB, DC to 40 GHz<br />

≤ 0.04 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 3.0 mΩ<br />

≤ 2.0 mΩ<br />

750 V rms<br />

250 V rms<br />

≥ 100 dB up to 1 GHz<br />

Mating cycles | Steckzyklen ≥ 500<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 22 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

0.80 Nm to 1.10 Nm<br />

Coupling test torque | Prüfdrehmoment<br />

1.70 Nm<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen<br />

MIL-STD 202, Method 107, Condition B<br />

Corrosion resistance | Korrosionsbeständigkeit<br />

MIL-STD 202, Method 101, Condition B<br />

Vibration | Vibration<br />

MIL-STD 202, Method 204, Condition D<br />

Shock | Schock<br />

MIL-STD 202, Method 213, Condition I<br />

Moisture resistance | Feuchtigkeitsbeständigkeit MIL-STD 202, Method 106<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

Gasket | Dichtung<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Stainless steel, passivated plating<br />

PS, PEEK<br />

Silicone<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

RPC-2.92<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

183


Series RPC-2.92<br />

Connector Heads<br />

Connector Heads<br />

Straight Plug<br />

xOrdering Number Remarks Return Loss<br />

x02 S 121-000 S3 with bead ≥ 23 dB @ DC to 40 GHz<br />

20<br />

ø 9<br />

SW8<br />

SW8<br />

Straight Jack<br />

xOrdering Number Remarks Return Loss<br />

x02 K 121-000 S3 with bead ≥ 23 dB @ DC to 40 GHz<br />

19.1<br />

ø 9<br />

SW8<br />

184<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-2.92<br />

Cable Connectors Semi- Rigid Cable<br />

Cable Connectors Semi-Rigid Cable<br />

Straight Plug, solder<br />

Semi-Rigid<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x02 S 141-271 E4<br />

x02 S 141-2W9 E4<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 22 dB @ 4 GHz to 32 GHz<br />

≥ 20 dB @ 32 GHz to 40 GHz<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 22 dB @ 4 GHz to 32 GHz<br />

≥ 20 dB @ 32 GHz to 40 GHz<br />

71 02 A5<br />

W9<br />

02 A8<br />

SW8<br />

10.4<br />

x02 S 121-271 S3 ≥ 23 dB @ DC to 40 GHz 71 02 A3<br />

35.7<br />

Straight Jack, solder<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x02 K 121-271 S3 ≥ 23 dB @ DC to 40 GHz 71 02 A3<br />

Semi-Rigid<br />

Panel Jack, 4-hole flange<br />

xOrdering Number Return Loss Cable<br />

Group<br />

Assembly<br />

Instruction<br />

x02 K 421-271 S3 ≥ 23 dB @ DC to 40 GHz 71 02 A3 MB 55<br />

Panel Piercing /<br />

PCB Layout<br />

Semi-Rigid<br />

RPC-2.92<br />

ø10<br />

SW8<br />

SW8<br />

SW9<br />

SW8<br />

34.7<br />

ø10<br />

SW8<br />

SW9<br />

SW8<br />

34.7<br />

12.7<br />

SW9<br />

SW8<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

185


Series RPC-2.92<br />

Panel Connectors / PCB Connectors SMD<br />

Panel Connectors<br />

Panel Plug<br />

xOrdering Number Remarks Return Loss<br />

x02 S 521-800 S3<br />

without glass bead,<br />

for hermetic sealed glass bead pin 0.3 mm<br />

02 Z 101-000<br />

≥ 19 dB @ DC to 40 GHz<br />

19.7<br />

SW8<br />

SW7<br />

SW8<br />

Panel Jack<br />

xOrdering Number Remarks Return Loss Panel Piercing /<br />

PCB Layout<br />

Packing Unit<br />

x02 K 421-800 S3<br />

without glass bead,<br />

for hermetic sealed glass bead<br />

pin 0.3 mm<br />

02 Z 101-000<br />

≥ 23 dB @ DC to 34 GHz<br />

≥ 19 dB @ 34 to 40 GHz<br />

MB 55<br />

100 blister<br />

10.4<br />

12.7<br />

x02 K 526-800 S3<br />

without glass bead,<br />

for hermetic sealed glass bead<br />

pin 0.3 mm<br />

02 Z 101-000<br />

≥ 23 dB @ DC to 34 GHz<br />

≥ 19 dB @ 34 to 40 GHz<br />

100 blister<br />

10.4<br />

Glass Bead<br />

xOrdering Number Remarks Return Loss<br />

x02 Z 101-000 hermetic sealed ≥ 19 dB @ DC to 40 GHz<br />

ø 0.3<br />

3.18<br />

ø 1.93<br />

1.4<br />

extended scale<br />

PCB Connectors SMD<br />

Right Angle Panel Jack, edge mount<br />

SMD<br />

xOrdering Number Remarks Return Loss Panel Piercing / PCB Layout<br />

x02 K 243-40M E3 for various PCB´s 0-3 mm ≥ 14 dB @ DC to 40 GHz MB 208<br />

14.5<br />

3 max.<br />

5<br />

14<br />

186<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-2.92<br />

Adaptors<br />

Adaptors<br />

Adaptor (In Series)<br />

xOrdering Number Version Remarks Return Loss Panel Piercing /<br />

PCB Layout<br />

x02 S 121-S00 S3 straight RPC-2.92 male - male ≥ 21 dB @ DC to 40 GHz<br />

x02 S 121-S20 S3 straight RPC-2.92 male - male,<br />

calibration adaptor<br />

≥ 32 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 40 GHz<br />

20.2<br />

ø 8<br />

SW8<br />

SW7<br />

SW8<br />

x02 S 121-K00 S3 straight RPC-2.92 male - female ≥ 21 dB @ DC to 40 GHz<br />

x02 S 121-K20 S3 straight RPC-2.92 male - female,<br />

calibration adaptor<br />

≥ 32 dB @ DC to 4 GHz,<br />

≥ 25 dB @ 4 to 40 GHz<br />

19.3<br />

ø 8<br />

SW8<br />

SW7<br />

x02 S 422-S00 S3 straight RPC-2.92 male-male, ruggedized,<br />

4-hole flange<br />

≥ 23 dB @ DC to 18 GHz<br />

≥ 17 dB @ 18 GHz to 40 GHz<br />

63.8<br />

25<br />

SW8<br />

SW12<br />

SW12<br />

SW19<br />

x02 K 121-K00 S3 straight RPC-2.92 female - female ≥ 21 dB @ DC to 40 GHz<br />

x02 K 121-K20 S3 straight RPC-2.92 female - female,<br />

calibration adaptor<br />

≥ 32 dB @ DC to 4 GHz<br />

≥ 25 dB @ 4 GHz to 40 GHz<br />

18.1<br />

ø 8<br />

SW7<br />

x02 K 521-S00 S3 straight RPC-2.92 female - male,<br />

round flange<br />

≥ 19 dB @ DC to 40 GHz MB 107<br />

36.2<br />

SW17<br />

SW8<br />

SW14<br />

SW8<br />

x02 K 621-K00 S3 straight RPC-2.92 female - female,<br />

hexagonal flange<br />

≥ 21 dB @ DC to 40 GHz MB 56<br />

22.23<br />

x02 K 641-KH0 S3 straight RPC-2.92 female - female,<br />

round flange,<br />

hermetic sealed<br />

≥ 15.5 dB dB @ DC to 40 GHz MB 58<br />

SW9.5<br />

SW8<br />

22.2<br />

RPC-2.92<br />

SW9.5<br />

SW7.5<br />

x02 KR 121-S00 S3 straight RPC-2.92 female, ruggedized - male ≥ 21 dB @ DC to 40 GHz<br />

35.9<br />

ø 22<br />

SW19<br />

SW7<br />

SW8<br />

x02 KR 121-K00 S3 straight RPC-2.92 female, ruggedized - female ≥ 21 dB @ DC to 40 GHz<br />

34.8<br />

ø 22<br />

SW19<br />

SW7<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

187


Series RPC-2.92<br />

Adaptor (Inter Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x02 S 118-S00 S3 straight RPC-2.92 male - Mini-SMP male ≥ 30 dB @ DC to 12 GHz<br />

≥ 26 dB @ 12 to 20 GHz<br />

≥ 18 dB @ 20 to 40 GHz<br />

26.2<br />

ø 9<br />

ø 8<br />

SW8<br />

SW7<br />

x02 S 118-K00 S3 straight RPC-2.92 male - Mini-SMP female ≥ 30 dB @ DC to 12 GHz<br />

≥ 26 dB @ 12 to 20 GHz<br />

≥ 18 dB @ 20 to 40 GHz<br />

26.2<br />

ø 9<br />

ø 8<br />

SW8<br />

SW7<br />

x02 K 118-S00 S3 straight RPC-2.92 female - Mini-SMP male ≥ 30 dB @ DC to 12 GHz<br />

≥ 26 dB @ 12 to 20 GHz<br />

≥ 18 dB @ 20 to 40 GHz<br />

25.2<br />

ø 9<br />

ø 8<br />

SW8<br />

SW7<br />

x02 K 118-K00 S3 straight RPC-2.92 female - Mini-SMP female ≥ 30 dB @ DC to 12 GHz<br />

≥ 26 dB @ 12 to 20 GHz<br />

≥ 18 dB @ 20 to 40 GHz<br />

25.2<br />

ø 9<br />

ø 8<br />

SW8<br />

SW7<br />

x02 S 119-S00 E3 straight RPC-2.92 male - SMP male ≥ 32 dB @ DC to 12 GHz<br />

≥ 26 dB @ 12 to 26.5 GHz<br />

≥ 21 dB @ 26.5 to 40 GHz<br />

26.8<br />

ø 9<br />

SW8<br />

SW8<br />

SW7<br />

x02 S 119-K00 E3 straight RPC-2.92 male - SMP female ≥ 32 dB @ DC to 12 GHz<br />

≥ 26 dB @ 12 to 26.5 GHz<br />

≥ 21 dB @ 26.5 to 40 GHz<br />

30<br />

ø 9<br />

SW8<br />

SW7<br />

x02 K 119-S00 E3 straight RPC-2.92 female - SMP male ≥ 32 dB @ DC to 12 GHz<br />

≥ 26 dB @ 12 to 26.5 GHz<br />

≥ 21 dB @ 26.5 to 40 GHz<br />

31.8<br />

ø 9<br />

SW8<br />

SW7<br />

x02 K 119-K00 E3 straight RPC-2.92 female - SMP female ≥ 32 dB @ DC to 12 GHz<br />

≥ 26 dB @ 12 to 26.5 GHz<br />

≥ 21 dB @ 26.5 to 40 GHz<br />

29<br />

ø9<br />

SW8<br />

SW7<br />

x02 S 108-S00 S3 straight RPC-2.92 male - RPC-1.85 male ≥ 19 dB @ DC to 40 GHz<br />

22.5<br />

ø 9<br />

SW8<br />

SW8<br />

SW8<br />

x02 S 108-K00 S3 straight RPC-2.92 male - RPC-1.85 female ≥ 19 dB @ DC to 40 GHz<br />

23.4<br />

ø 9<br />

SW8<br />

SW8<br />

188<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-2.92<br />

xOrdering Number Version Remarks Return Loss<br />

x02 K 108-S00 S3 straight RPC-2.92 female - RPC-1.85 male ≥ 19 dB @ DC to 40 GHz<br />

21.7<br />

ø 9<br />

SW8<br />

SW8<br />

x02 K 108-K00 S3 straight RPC-2.92 female - RPC-1.85 female ≥ 19 dB @ DC to 40 GHz<br />

22.5<br />

ø 9<br />

SW8<br />

x02 S 109-S00 S3 straight RPC-2.92 male - RPC-2.40 male ≥ 19 dB @ DC to 40 GHz<br />

22.5<br />

ø 9<br />

SW8<br />

SW8<br />

SW8<br />

x02 S 109-K00 S3 straight RPC-2.92 male - RPC-2.40 female ≥ 19 dB @ DC to 40 GHz<br />

23.4<br />

ø 9<br />

SW8<br />

SW8<br />

x02 K 109-S00 S3 straight RPC-2.92 female - RPC-2.40 male ≥ 19 dB @ DC to 40 GHz<br />

21.7<br />

ø 9<br />

SW8<br />

SW8<br />

x02 K 109-K00 S3 straight RPC-2.92 female - RPC-2.40 female ≥ 19 dB @ DC to 40 GHz<br />

22.5<br />

ø 9<br />

SW8<br />

x02 KR 107-P00 S3 straight RPC-2.92 female, ruggedized - RPC-7 ≥ 28 dB @ DC to 18 GHz<br />

45.2<br />

ø 22<br />

x02 KR 105-S00 S3 straight RPC-2.92 female, ruggedized -<br />

RPC-N 50 Ω male<br />

≥ 26 dB @ DC to 18 GHz<br />

SW19<br />

SW19<br />

44.84<br />

ø 22<br />

RPC-2.92<br />

SW19<br />

SW20<br />

x02 KR 105-K00 S3 straight RPC-2.92 female, ruggedized -<br />

RPC-N 50 Ω female<br />

≥ 26 dB @ DC to 18 GHz<br />

43.8<br />

ø 22<br />

ø 15.7<br />

SW19<br />

SW14<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

189


Series RPC-2.92<br />

Interchangeable Port Connector System<br />

Interchangeable Port Connector System<br />

RPC 2.92 - RPC-SL 40 GHz<br />

xOrdering Number Version Remarks Return Loss<br />

x02 S 1P4-S00 S3 straight RPC-2.92 male - RPC-SL 40 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

≥ 19 dB @ 26.5 to 40 GHz<br />

1<br />

29.1<br />

ø 19<br />

SW8<br />

SW14<br />

SW18<br />

x02 K 1P4-S00 S3 straight RPC-2.92 female - RPC-SL 40 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

≥ 19 dB @ 26.5 to 40 GHz<br />

1<br />

0<br />

0<br />

28<br />

ø 19<br />

SW14<br />

SW18<br />

see also chapter interchangeable port connector system<br />

190<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-2.92<br />

Tools<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

x03 W 021-000<br />

Remarks<br />

flat 8 mm - 0.9 Nm torque for RPC-3.50 , RPC- 2.92, RPC-2.40, RPC-1.85<br />

136.5<br />

Gauge<br />

xOrdering Number<br />

x03 W 00S-000<br />

Remarks<br />

compatible to male connectors for RPC-3.50, RPC-2.92<br />

incl. gauge block<br />

ø15<br />

x03 W 00K-000<br />

compatible to female connectors for RPC-3.50, RPC-2.92<br />

incl. gauge block<br />

RPC-2.92<br />

30<br />

33<br />

ø15<br />

SW8<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

191


RPC-2.40 connectors from <strong>Rosenberger</strong> – with 50 Ω impedance<br />

and 2.40 mm outer conductor – have been designed for test &<br />

measurement applications up to 50 GHz and are characterized by<br />

high reliability and outstanding repeatability performance.<br />

RPC-2.40-Steckverbinder von <strong>Rosenberger</strong> – 50 Ω-Präzisionssteckverbinder<br />

mit 2.40 mm Außenleiter – sind konzipiert<br />

für Messtechnik-Anwendungen bis 50 GHz und zeichnen<br />

sich aus durch sehr hohe Zuverlässigkeit und beste<br />

Reproduzierbarkeit.<br />

RPC-2.40 connectors are intermateable with other 2.40 mm<br />

connector series, such as APC-2.40, OS-50, HP-2.40 or<br />

RPC-1.85- and V connectors.<br />

RPC-2.40 Steckverbinder sind steckkompatibel zu anderen<br />

2.40 mm-Steckverbindern, z. B. APC-2.40-, OS-50-,<br />

HP-2.40- sowie zu RPC-1.85- und V-Steckverbindern.<br />

<strong>Rosenberger</strong> offers a wide range of RPC-2.40 cable and PCB<br />

connectors, adaptors, interchangeable port connectors as well<br />

as test & measurement accessories such as RPC-2.40 calibration<br />

kits, test cables or test devices, e.g. opens, shorts, loads, sliding<br />

loads or airlines.<br />

<strong>Rosenberger</strong> bietet RPC-2.40-Kabel- und Leiterplatten-<br />

Steckverbinder, Adapter Wechselport-Steckverbinder sowie<br />

Messzubehör wie RPC-2.40-Kalibrier-Kits, <strong>Test</strong>kabel oder<br />

<strong>Test</strong>zubehör, z. B. Opens, Shorts, Loads, Sliding Loads und<br />

Luftleitungen.


Series RPC-2.40<br />

Features<br />

Frequency range DC to 50 GHz<br />

Return loss (cable connector straight) ≥ 23 dB<br />

Impedance 50 Ω<br />

Threaded coupling<br />

Damage free connection<br />

Intermateable with V and 1.85 mm connectors<br />

RPC-2.40


Series RPC-2.40<br />

1Series RPC- 2.40<br />

Interface Dimensions Series RPC-2.40 (code 09)<br />

REFERENCE PLANE<br />

Referenzebene<br />

REFERENCE PLANE<br />

Referenzebene<br />

D<br />

D<br />

A<br />

E<br />

B<br />

C<br />

F<br />

F<br />

C<br />

B<br />

E<br />

A<br />

MALE<br />

Stecker<br />

FEMALE<br />

Kuppler<br />

Series RPC-2.40<br />

Male | Stecker<br />

Female | Kuppler<br />

dimension min. max. min. max.<br />

A 1.03 1.05 1.03 1.05<br />

B 2.39 2.41 2.39 2.41<br />

C 4.725 4.750 4.770 4.795<br />

D 0.00 0.05 0.00 0.05<br />

E 0.505 0.52 0.54 0.56<br />

F M7 x 0.75 - 6H M7 x 0.75 - 6g<br />

194<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-2.40<br />

Technology<br />

Technical Data Series RPC-2.40<br />

Applicable standards | Anwendbare Standards<br />

Mechanically compatible with | Mechanisch kompatibel mit<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (cable connector straight) | Rückflußdämpfung (Kabelsteckverbinder, gerade)<br />

Insertion loss (cable connector straight) | Dämpfung (Kabelsteckverbinder, gerade)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

RPC-1.85<br />

50 Ω<br />

DC to 50 GHz<br />

≥ 23 dB, DC to 50 GHz<br />

≤ 0.05 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 4.0 mΩ<br />

≤ 2.5 mΩ<br />

500 V rms<br />

150 V rms<br />

≥ 100 dB up to 1 GHz<br />

Mating cycles | Steckzyklen ≥ 500<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 20 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

0.80 Nm to 1.10 Nm<br />

Coupling test torque | Prüfdrehmoment<br />

1.65 Nm<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen IEC 61169-1, Subclause 9.4.4<br />

Corrosion resistance | Korrosionsbeständigkeit IEC 61169-1, Subclause 9.4.6<br />

Vibration | Vibration IEC 61169-1, Subclause 9.3.3<br />

Shock | Schock IEC 61169-1, Subclause 9.3.14<br />

Moisture resistance | Feuchtigkeitsbeständigkeit IEC 61169-1, Subclause 9.4.3<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Stainless steel, passivated<br />

PEEK<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

RPC-2.40<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

195


Series RPC-2.40<br />

Cable Connectors Semi- Rigid Cable<br />

Cable Connectors Semi-Rigid Cable<br />

Straight Plug, solder<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x09 S 121-271 S3 ≥ 23 dB @ DC to 50 GHz 71 02 A3<br />

27.9<br />

Semi-Rigid<br />

ø 9<br />

SW8 SW8 SW8<br />

Straight Jack, solder<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x09 K 121-271 S3 ≥ 23 dB @ DC to 50 GHz 71 02 A3<br />

29<br />

Semi-Rigid<br />

ø 9<br />

SW8<br />

SW8<br />

Panel Plug, 4-hole flange<br />

xOrdering Number Return Loss Cable Group Assembly<br />

Instruction<br />

x09 S 421-271 S3 ≥ 23 dB @ DC to 50 GHz 71 02 A3 MB 55<br />

Panel Piercing /<br />

PCB Layout<br />

27.9<br />

Semi-Rigid<br />

12.7<br />

SW8<br />

SW8<br />

Panel Jack, 4-hole flange<br />

xOrdering Number Return Loss Cable Group Assembly<br />

Instruction<br />

x09 K 421-271 S3 ≥ 23 dB @ DC to 50 GHz 71 02 A3 MB 55<br />

Panel Piercing /<br />

PCB Layout<br />

29<br />

Semi-Rigid<br />

12.7<br />

SW8<br />

196<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-2.40<br />

PCB Connectors SMD<br />

PCB Connectors SMD<br />

Right Angle Panel Jack, edge mount<br />

xOrdering Number Remarks Return Loss Panel Piercing /<br />

PCB Layout<br />

SMD<br />

x09 K 243-40M E3 for various PCB´s 0-3 mm ≥ 12 dB @ DC to 50 GHz MB 208 14.5<br />

3 max.<br />

5<br />

RPC-2.40<br />

14<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

197


Series RPC-2.40<br />

Interchangeable Port Connector System<br />

Interchangeable Port Connector System<br />

RPC 2.40 - RPC-SL 40 GHz<br />

xOrdering Number Version Remarks Return Loss<br />

x09 S 1P4-S00 S3 straight RPC-2.40 male - RPC-SL 40 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

≥ 19 dB @ 26.5 GHz to 40 GHz<br />

28.4<br />

SW18<br />

x09 K 1P4-S00 S3 straight RPC-2.40 female - RPC-SL 40 GHz male ≥ 21 dB @ DC to 26.5 GHz<br />

≥ 19 dB @ 26.5 GHz to 40 GHz<br />

29.1<br />

SW18<br />

see also chapter interchangeable port connector system<br />

Adaptors<br />

198<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-2.40<br />

Adaptors<br />

Adaptor (In Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x09 K 121-K00 S3 straight RPC-2,40 female - female ≥ 17 dB @ DC to 50 GHz<br />

x09 K 121-K20 S3 straight RPC-2,40 female - female,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 50 GHz<br />

23.65<br />

SW7<br />

x09 S 121-K00 S3 straight RPC-2,40 male - female ≥ 17 dB @ DC to 50 GHz<br />

x09 S 121-K20 S3 straight RPC-2,40 male - female,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz,<br />

≥ 17 dB @ 4 GHz to 50 GHz<br />

22.8<br />

SW8<br />

SW7<br />

x09 S 121-S00 S3 straight RPC-2,40 male - male ≥ 17 dB @ DC to 50 GHz<br />

x09 S 121-S20 S3 straight RPC-2,40 male - male,<br />

calibration adaptor<br />

≥ 30 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 50 GHz<br />

22<br />

SW8<br />

SW5 SW8<br />

Adaptors<br />

Adaptor (Inter Series)<br />

xOrdering Number straight Remarks Return Loss<br />

x02 S 109-S00 S3 straight RPC-2.92 male - RPC-2.40 male ≥ 19 dB @ DC to 40 GHz<br />

22.5<br />

x02 S 109-K00 S3 straight RPC-2.92 male - RPC-2.40 female ≥ 19 dB @ DC to 40 GHz<br />

x02 K 109-S00 S3 straight RPC-2.92 female - RPC-2.40 male ≥ 19 dB @ DC to 40 GHz<br />

x02 K 109-K00 S3 straight RPC-2.92 female - RPC-2.40 female ≥ 19 dB @ DC to 40 GHz<br />

RPC-2.40<br />

ø 9<br />

SW8<br />

SW8<br />

SW8<br />

23.4<br />

ø 9<br />

SW8<br />

SW8<br />

21.7<br />

ø 9<br />

SW8<br />

SW8<br />

22.5<br />

ø 9<br />

SW8<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

199


Series RPC-2.40<br />

xOrdering Number straight Remarks Return Loss<br />

x03 S 109-S00 S3 straight RPC-3.50 male - RPC 2.40 male ≥ 23 dB @ DC to 26.5 GHz<br />

35.3<br />

ø 9<br />

SW8<br />

SW8<br />

SW8 SW8<br />

x03 S 109-K00 S3 straight RPC-3.50 male - RPC 2.40 female ≥ 23 dB @ DC to 26.5 GHz<br />

32.2<br />

ø 9<br />

SW8 SW8 SW8<br />

x03 K 109-S00 S3 straight RPC-3.50 female - RPC 2.40 male ≥ 23 dB @ DC to 26.5 GHz<br />

34.6<br />

ø 9<br />

SW8 SW8 SW8<br />

x03 K 109-K00 S3 straight RPC-3.50 female - RPC 2.40 female ≥ 23 dB @ DC to 26.5 GHz<br />

31.1<br />

ø 9<br />

SW8<br />

SW8<br />

200<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-2.40<br />

Tools<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

x03 W 021-000<br />

Remarks<br />

flat 8 mm - 0.9 Nm torque for RPC-3.50 , RPC- 2.92, RPC-2.40, RPC-1.85<br />

136.5<br />

Gauge<br />

xOrdering Number<br />

x08 W 00S-000<br />

Remarks<br />

compatible to male connectors for RPC-2.40, RPC-1.85<br />

incl. gauge block<br />

ø15<br />

x08 W 00K-000<br />

compatible to female connectors for RPC-2.40, RPC-1.85<br />

incl. gauge block<br />

RPC-2.40<br />

30<br />

34.2<br />

ø15<br />

SW8<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

201


RPC-1.85 precision connectors from <strong>Rosenberger</strong> – with 50 Ω<br />

impedance and 1.85 mm outer conductor diameter – have been<br />

designed for test & measurement applications up to 65 GHz.<br />

RPC-1.85-Steckverbinder von <strong>Rosenberger</strong> – 50 Ω-Präzisions-<br />

steckverbinder mit 1.85 mm Außenleiter – sind konzipiert für<br />

Messtechnik-Anwendungen bis 65 GHz.<br />

Outstanding characteristics are high reliability and outstanding<br />

repeatability performance, RPC-1.85 connectors are intermateable<br />

with 2.40 mm connector series, such as APC-2.40, OS-50,<br />

HP-2.40 or RPC-2.40 and V connectors.<br />

RPC-1.85-Steckverbinder zeichnen sich aus durch sehr hohe<br />

Zuverlässigkeit und beste Reproduzierbarkeit, sie sind steckkompatibel<br />

zu allen entsprechenden 2.40 mm-Steckverbindern,<br />

z. B. APC-2.40-, OS-50-, HP-2.40-, RPC-2.40- sowie zu<br />

V-Steckverbindern.<br />

The comprehensive product range includes RPC-1.85 cable and<br />

panel connectors, adaptors and test & measurement accessories<br />

such as RPC-1.85 calibration kits, test cables opens, shorts, loads,<br />

attenuators, sliding loads or airlines.<br />

Das Produktspektrum von <strong>Rosenberger</strong> umfasst RPC-<br />

1.85-Kabel- und Gehäuse-Steckverbinder, Adapter sowie<br />

Messzubehör wie RPC-1.85-Kalibrier-Kits, <strong>Test</strong>kabel oder<br />

Opens, Shorts, Loads, Dämpfungsglieder, Sliding Loads und<br />

Luftleitungen.


Series RPC-1.85<br />

Features<br />

Interface according to IEC 61169-32<br />

Frequency range DC to 65 GHz<br />

Return loss (cable connector straight) ≥ 20 dB<br />

Impedance 50 Ω<br />

Threaded coupling<br />

Damage free connection<br />

Intermateable with V and 2.40 mm connectors<br />

RPC-1.85


Series RPC-1.85<br />

1Series RPC- 1.85<br />

Interface Dimensions Series RPC-1.85 (code 08)<br />

REFERENCE PLANE<br />

Referenzebene<br />

REFERENCE PLANE<br />

Referenzebene<br />

D<br />

D<br />

A<br />

E<br />

B<br />

C<br />

F<br />

F<br />

C<br />

B<br />

E<br />

A<br />

MALE<br />

Stecker<br />

FEMALE<br />

Kuppler<br />

Series RPC-1.85<br />

Male | Stecker<br />

Female | Kuppler<br />

dimension min. max. min. max.<br />

A 0.799 0.809 0.799 0.809<br />

B 1.84 1.86 1.84 1.86<br />

C 4.725 4.750 4.770 4.795<br />

D 0.00 0.05 0.00 0.05<br />

E 0.505 0.52 0.54 0.56<br />

F M7 x 0.75 - 6H M7 x 0.75 - 6g<br />

204<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-1.85<br />

Technology<br />

Technical Data Series RPC-1.85<br />

Applicable standards | Anwendbare Standards<br />

Interface according to | Interface gemäß IEC 61169-32<br />

Mechanically compatible with | Mechanisch kompatibel mit<br />

RPC-2.40<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (cable connector straight) | Rückflußdämpfung (Kabelsteckverbinder, gerade)<br />

Insertion loss (cable connector straight) | Dämpfung (Kabelsteckverbinder, gerade)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

50 Ω<br />

DC to 65 GHz<br />

≥ 20 dB, DC to 65 GHz<br />

≤ 0.05 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 4.0 mΩ<br />

≤ 2.5 mΩ<br />

500 V rms<br />

150 V rms<br />

≥ 100 dB up to 1 GHz<br />

Mating cycles | Steckzyklen ≥ 500<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 20 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

0.80 Nm to 1.10 Nm<br />

Coupling test torque | Prüfdrehmoment<br />

1.65 Nm<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen IEC 61169-1, Subclause 9.4.4<br />

Corrosion resistance | Korrosionsbeständigkeit IEC 61169-1, Subclause 9.4.6<br />

Vibration | Vibration IEC 61169-1, Subclause 9.3.3<br />

Shock | Schock IEC 61169-1, Subclause 9.3.14<br />

Moisture resistance | Feuchtigkeitsbeständigkeit IEC 61169-1, Subclause 9.4.3<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Stainless steel, passivated<br />

PEEK<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

RPC-1.85<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

205


Series RPC-1.85<br />

Cable Connectors Semi- Rigid Cable<br />

Cable Connectors Semi-Rigid Cable<br />

Straight Plug, solder<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x08 S 121-270 S3 ≥ 20 dB @ DC to 65 GHz 70 02 A6<br />

x08 S 121-271 S3 ≥ 20 dB @ DC to 65 GHz 71 02 A3<br />

x08 S 121-2W7 S3 ≥ 20 dB @ DC to 65 GHz W7 02 A3<br />

29.5<br />

Semi-Rigid<br />

SW8 SW8 SW8<br />

Straight Plug, solder, without pin, without dielectric<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x08 S 101-271 D ≥ 20 dB @ DC to 65 GHz 71 08 A1<br />

11.2<br />

Semi-Rigid<br />

SW8<br />

Straight Jack, solder<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x08 K 121-270 S3 ≥ 20 dB @ DC to 65 GHz 70 02 A6<br />

x08 K 121-271 S3 ≥ 20 dB @ DC to 65 GHz 71 02 A3<br />

x08 K 121-2W7 S3 ≥ 20 dB @ DC to 65 GHz W7 02 A3<br />

30<br />

Semi-Rigid<br />

SW8<br />

SW8<br />

Panel Plug, 4-hole flange<br />

xOrdering Number Return Loss Cable Group Assembly<br />

Instruction<br />

x08 S 421-270 S3 ≥ 20 dB @ DC to 65 GHz 70 02 A6 MB 71<br />

x08 S 421-271 S3 ≥ 20 dB @ DC to 65 GHz 71 02 A3 MB 71<br />

x08 S 421-2W7 S3 ≥ 20 dB @ DC to 65 GHz W7 02 A3 MB 71<br />

Panel Piercing /<br />

PCB Layout<br />

29.6<br />

Semi-Rigid<br />

16<br />

SW8<br />

SW8<br />

Panel Jack, 4-hole flange<br />

xOrdering Number Return Loss Cable Group Assembly<br />

Instruction<br />

x08 K 421-270 S3 ≥ 20 dB @ DC to 65 GHz 70 02 A6 MB 71<br />

x08 K 421-271 S3 ≥ 20 dB @ DC to 65 GHz 71 02 A3 MB 71<br />

x08 K 421-2W7 S3 ≥ 20 dB @ DC to 65 GHz W7 02 A3 MB 71<br />

Panel Piercing /<br />

PCB Layout<br />

30<br />

Semi-Rigid<br />

16<br />

SW8<br />

206<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-1.85<br />

Panel Connectors<br />

Panel Connectors<br />

Panel Jack<br />

xOrdering Number Remarks Return Loss Packing Unit<br />

x08 K 521-800 S3<br />

without glass bead,<br />

for hermetic sealed glass bead pin 0,24 mm<br />

08 Z 101-000<br />

≥ 15 dB @ DC to 65 GHz 100<br />

11.5<br />

Glass Bead<br />

xOrdering Number Remarks Return Loss<br />

x08 Z 101-000 hermetic sealed ≥ 17 dB @ DC to 65 GHz<br />

ø 0.23<br />

2.85<br />

ø 1.73<br />

RPC-1.85<br />

1.4<br />

extended scale<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

207


Series RPC-1.85<br />

Adaptors<br />

Adaptors<br />

Adaptor (In Series)<br />

xOrdering Number Version Remarks Return Loss Panel Piercing /<br />

PCB Layout<br />

x08 S 121-S00 S3 straight RPC-1,85 male - male ≥ 17 dB @ DC to 65 GHz<br />

x08 S 121-S20 S3 straight RPC-1,85 male - male,<br />

calibration adaptor<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 65 GHz<br />

22.1<br />

SW8<br />

SW5 SW8<br />

x08 S 121-K00 S3 straight RPC-1,85 male - female ≥ 17 dB @ DC to 65 GHz<br />

x08 S 121-K20 S3 straight RPC-1,85 male - female,<br />

calibration adaptor<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 65 GHz<br />

22.9<br />

ø 8<br />

SW8<br />

SW7<br />

x08 K 121-K00 S3 straight RPC-1,85 female - female ≥ 17 dB @ DC to 65 GHz<br />

x08 K 121-K20 S3 straight RPC-1.85 female - female,<br />

calibration adaptor<br />

≥ 28 dB @ DC to 4 GHz<br />

≥ 17 dB @ 4 GHz to 65 GHz<br />

23.6<br />

ø 8<br />

SW7<br />

x08 K 641-KH0 S3 straight RPC-1.85 male - male,<br />

panel mount, round flange,<br />

hermetic sealed<br />

≥ 12 dB @ DC to 65 GHz MB 58<br />

24.2<br />

SW9.5 SW7.5<br />

208<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-1.85<br />

Adaptor (Inter Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x08 S 118-S00 S3 straight RPC-1.85 male - Mini-SMP male ≥ 30 dB @ DC to 12 GHz<br />

≥ 18 dB @ 12 to 50 GHz<br />

≥ 15 dB @ 50 to 65 GHz<br />

24.5<br />

SW8<br />

SW7<br />

x08 S 118-K00 S3 straight RPC-1.85 male - Mini-SMP female ≥ 30 dB @ DC to 12 GHz<br />

≥ 18 dB @ 12 to 50 GHz<br />

≥ 15 dB @ 50 to 65 GHz<br />

x08 K 118-S00 S3 straight RPC-1.85 female - Mini-SMP male ≥ 30 dB @ DC to 12 GHz<br />

≥ 18 dB @ 12 to 50 GHz<br />

≥ 15 dB @ 50 to 65 GHz<br />

x08 K 118-K00 S3 straight RPC-1.85 female - Mini-SMP female ≥ 30 dB @ DC to 12 GHz<br />

≥ 18 dB @ 12 to 50 GHz<br />

≥ 15 dB @ 50 to 65 GHz<br />

x01 S 108-S00 D3 straight RPC-1.00 male - RPC-1.85 male ≥ 19dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 to 50 GHz<br />

≥ 14 dB @ 50 to 65 GHz<br />

x01 S 108-K00 D3 straight RPC-1.00 male - RPC-1.85 female ≥ 19dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 to 50 GHz<br />

≥ 14 dB @ 50 to 65 GHz<br />

x01 K 108-S00 D3 straight RPC-1.00 female - RPC-1.85 male ≥ 19dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 to 50 GHz<br />

≥ 14 dB @ 50 to 65 GHz<br />

x01 K 108-K00 D3 straight RPC-1.00 female - RPC-1.85 female ≥ 19dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 to 50 GHz<br />

≥ 14 dB @ 50 to 65 GHz<br />

RPC-1.85<br />

ø 8<br />

22.4<br />

ø 8<br />

SW8<br />

SW7<br />

25.2<br />

ø 8<br />

SW7 SW7<br />

23<br />

ø 8<br />

SW7<br />

SW7<br />

18.2<br />

SW6<br />

SW5<br />

SW8<br />

19.2<br />

SW6<br />

SW5<br />

18.4<br />

SW5<br />

SW8<br />

19.2<br />

SW5<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

209


Series RPC-1.85<br />

xOrdering Number Version Remarks Return Loss<br />

x02 S 108-S00 S3 straight RPC-2.92 male - RPC-1.85 male ≥ 19 dB @ DC to 40 GHz<br />

22.5<br />

ø 9<br />

SW8<br />

SW8<br />

SW8<br />

x02 S 108-K00 S3 straight RPC-2.92 male - RPC-1.85 female ≥ 19 dB @ DC to 40 GHz<br />

23.4<br />

ø 9<br />

SW8<br />

SW8<br />

x02 K 108-S00 S3 straight RPC-2.92 female - RPC-1.85 male ≥ 19 dB @ DC to 40 GHz<br />

21.7<br />

ø 9<br />

SW8<br />

SW8<br />

x02 K 108-K00 S3 straight RPC-2.92 female - RPC-1.85 female ≥ 19 dB @ DC to 40 GHz<br />

22.5<br />

ø 9<br />

SW8<br />

210<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-1.85<br />

Tools<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

x03 W 021-000<br />

Remarks<br />

flat 8 mm - 0.9 Nm torque for RPC-3.50 , RPC- 2.92, RPC-2.40, RPC-1.85<br />

136.5<br />

Gauge<br />

xOrdering Number<br />

x08 W 00S-000<br />

Remarks<br />

compatible to male connectors for RPC-2.40, RPC-1.85<br />

incl. gauge block<br />

ø15<br />

x08 W 00K-000<br />

compatible to female connectors for RPC-2.40, RPC-1.85<br />

incl. gauge block<br />

RPC-1.85<br />

30<br />

34.2<br />

ø15<br />

SW8<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

211


RPC-1.00 connectors from <strong>Rosenberger</strong> – with 50 Ω impedance<br />

and 1.00 mm outer conductor – can be used for test & measurement<br />

applications up to 110 GHz.<br />

<strong>Rosenberger</strong> RPC-1.00-Steckverbinder sind 50 Ω-Präzisionssteckverbinder<br />

mit 1.00 mm Außenleiterdurchmesser und<br />

hervorragenden Eigenschaften für Messtechnik-Anwendungen<br />

bis 110 GHz.<br />

They are characterized by excellent technical data over the full<br />

frequency range, meet the highest levels of reliability and repeatability<br />

of performance and are intermateable with 1.00 mm connectors,<br />

e.g. Agilent 1.00.<br />

RPC-1.00-Steckverbinder sind gekennzeichnet durch sehr<br />

hohe Zuverlässigkeit und hervorragende Reproduzierbarkeit.<br />

Sie sind steckkompatibel zu 1.00 mm-Steckverbindern, z.B.<br />

Agilent-1.00.<br />

Additionally to cable connectors, there are also available adaptors<br />

and test & measurement accessories such as RPC-1.00 calibration<br />

kits, test cables or test devices, e.g. opens, shorts, loads or<br />

airlines.<br />

Neben einer Reihe von Kabel-Steckverbindern sind auch<br />

Adapter und Messzubehör erhältlich wie z.B. RPC-1.00-<br />

Kalibrier-Kits, <strong>Test</strong>kabel oder <strong>Test</strong>zubehör, z. B. Opens, Shorts,<br />

Loads oder Luftleitungen.


Series RPC-1.00<br />

Features<br />

Interface according to IEC 61169-31<br />

Frequency range DC to 110 GHz<br />

Return loss ( cable connector straight) ≥ 14 dB<br />

Impedance 50 Ω<br />

Threaded coupling<br />

Damage free connection<br />

Intermateable with W connectors<br />

PRC-1.00


Series RPC-1.00<br />

1Series RPC- 1.00<br />

Interface Dimensions Series RPC-1.00 (code 01)<br />

D<br />

REFERENCE PLANE<br />

Referenzebene<br />

REFERENCE PLANE<br />

Referenzebene<br />

D<br />

A<br />

E<br />

B<br />

C<br />

F<br />

F<br />

C<br />

B<br />

E<br />

A<br />

MALE<br />

Stecker<br />

FEMALE<br />

Kuppler<br />

Series RPC-1.00<br />

Male | Stecker<br />

Female | Kuppler<br />

dimension min. max. min. max.<br />

A 0.4315 0.4365 0.4315 0.4365<br />

B 0.995 1.005 0.995 1.005<br />

C 2.348 2.368 2.380 2.400<br />

D 0.000 0.050 0.000 0.050<br />

E 0.245 0.255 0.270 0.290<br />

F M4 x 0.7 - 6H M4 x 0.7 - 6g<br />

214<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-1.00<br />

Technology<br />

Technical Data Series RPC-1.00<br />

Applicable standards | Anwendbare Standards<br />

Interface according to | Interface gemäß IEC 61169-31<br />

Electrical data | Elektrische Daten<br />

Impedance | Wellenwiderstand<br />

Frequency range | Frequenzbereich<br />

Return loss (cable connector straight) | Rückflußdämpfung (Kabelsteckverbinder, gerade)<br />

Insertion loss (cable connector straight) | Dämpfung (Kabelsteckverbinder, gerade)<br />

Insulation resistance | Isolationswiderstand<br />

Center contact resistance | Übergangswiderstand Innenleiter<br />

Outer contact resistance | Übergangswiderstand Außenleiter<br />

<strong>Test</strong> voltage | Prüfspannung<br />

Working voltage | Betriebsspannung<br />

RF-leakage | Schirmdämpfung<br />

Mechanical data | Mechanische Daten<br />

50 Ω<br />

DC to 110 GHz<br />

≥ 23 dB, DC to 50 GHz<br />

≥ 19 dB, 50 GHz to 75 GHz<br />

≥ 14 dB, 75 GHz to 110 GHz<br />

≤ 0.05 dB x ⎟f[GHz]<br />

≥ 5 GΩ<br />

≤ 4.0 mΩ<br />

≤ 1.0 mΩ<br />

500 V rms<br />

150 V rms<br />

≥ 90 dB up to 1 GHz<br />

Mating cycles | Steckzyklen ≥ 500<br />

Center contact captivation | Innenleiter Haltekraft<br />

≥ 10 N<br />

Coupling torque recommended | Anzugsdrehmoment empfohlen<br />

0.3 Nm to 0.41 Nm<br />

Coupling test torque | Prüfdrehmoment<br />

0.70 Nm<br />

Environmental data | Umweltdaten<br />

Temperature range | Temperaturbereich -40 °C to +85 °C<br />

Thermal shock | Temperaturzyklen IEC 61169-1, Subclause 9.4.4<br />

Corrosion resistance | Korrosionsbeständigkeit IEC 61169-1, Subclause 9.4.6<br />

Vibration | Vibration IEC 61169-1, Subclause 9.3.3<br />

Shock | Schock IEC 61169-1, Subclause 9.3.14<br />

Moisture resistance | Feuchtigkeitsbeständigkeit IEC 61169-1, Subclause 9.4.3<br />

Max. soldering temperature | Maximale Löttemperatur<br />

IEC 61760-1, +260 °C for 10 sec.<br />

Materials | Materialien<br />

Center contact | Innenleiter<br />

Outer contact | Außenleiter<br />

Dielectric | Dielektrikum<br />

<strong>Rosenberger</strong>-connectors fulfill in principle the indicated data of the Technical Data.<br />

Individual values of connectors may deviate depending upon application, design,<br />

type of cable, assembly method and execution. Specific data sheets for particular<br />

products can be provided on request from your <strong>Rosenberger</strong> sales partner.<br />

Beryllium copper, gold-plated<br />

Beryllium copper, gold-plated<br />

PEEK<br />

<strong>Rosenberger</strong>-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten<br />

angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausführung<br />

können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische<br />

Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem <strong>Rosenberger</strong>-Ansprechpartner.<br />

RPC-1.00<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

215


Series RPC-1.00<br />

Cable Connectors Semi- Rigid Cable<br />

Cable Connectors Semi-Rigid Cable<br />

Straight Plug, solder<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x01 S 101-270 E3<br />

≥ 23 dB @ DC to 50 GHz<br />

≥ 19 dB @ 50 to 75 GHz<br />

≥ 14 dB @ 75 to 110 GHz<br />

70 01 A1<br />

19.7<br />

Semi-Rigid<br />

ø 7<br />

SW6 SW6 SW6<br />

Straight Jack, solder<br />

xOrdering Number Return Loss Cable Group Assembly Instruction<br />

x01 K 101-270 E3<br />

≥ 23 dB @ DC to 50 GHz<br />

≥ 19 dB @ 50 to 75 GHz<br />

≥ 14 dB @ 75 to 110 GHz<br />

70 01 A1<br />

19.8<br />

Semi-Rigid<br />

ø 7<br />

SW6<br />

SW6<br />

216<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-1.00<br />

Adaptors<br />

Adaptors<br />

Adaptor (In Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x01 S 101-S20 D3 straight RPC-1.00 male - male,<br />

calibration adaptor,<br />

phase matched<br />

≥ 20 dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 GHz to 50 GHz<br />

≥ 15 dB @ 50 GHz to 75 GHz<br />

≥ 12 dB @ 75 GHz to 110 GHz<br />

14.2<br />

x01 S 101-K20 D3 straight RPC-1.00 male - female,<br />

calibration adaptor,<br />

phase matched<br />

≥ 20 dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 GHz to 50 GHz<br />

≥ 15 dB @ 50 GHz to 75 GHz<br />

≥ 12 dB @ 75 GHz to 110 GHz<br />

SW5<br />

14.4<br />

SW6<br />

SW6<br />

SW5<br />

x01 S 101-K01 D3 straight RPC-1.00 male - female,<br />

calibration adaptor,<br />

with retractable male nut<br />

≥ 20 dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 GHz to 50 GHz<br />

≥ 15 dB @ 50 GHz to 75 GHz<br />

≥ 12 dB @ 75 GHz to 110 GHz<br />

19<br />

SW6<br />

SW5<br />

x01 S 101-K02 D3 straight RPC-1.00 male - female,<br />

calibration adaptor,<br />

with retractable female nut<br />

≥ 20 dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 GHz to 50 GHz<br />

≥ 15 dB @ 50 GHz to 75 GHz<br />

≥ 12 dB @ 75 GHz to 110 GHz<br />

19.2<br />

SW6<br />

SW5<br />

x01 K 101-K20 D3 straight RPC-1.00 female - female,<br />

calibration adaptor,<br />

phase matched<br />

≥ 20 dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 GHz to 50 GHz<br />

≥ 15 dB @ 50 GHz to 75 GHz<br />

≥ 12 dB @ 75 GHz to 110 GHz<br />

14.4<br />

ø 6<br />

SW5<br />

Adaptor (Inter Series)<br />

xOrdering Number Version Remarks Return Loss<br />

x01 S 108-S00 D3 straight RPC-1.00 male - RPC-1.85 male ≥ 19dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 to 50 GHz<br />

≥ 14 dB @ 50 to 65 GHz<br />

18.2<br />

SW6<br />

SW5<br />

SW8<br />

x01 S 108-K00 D3 straight RPC-1.00 male - RPC-1.85 female ≥ 19dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 to 50 GHz<br />

≥ 14 dB @ 50 to 65 GHz<br />

19.2<br />

SW6<br />

SW5<br />

x01 K 108-S00 D3 straight RPC-1.00 female - RPC-1.85 male ≥ 19dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 to 50 GHz<br />

≥ 14 dB @ 50 to 65 GHz<br />

18.4<br />

SW5<br />

SW8<br />

x01 K 108-K00 D3 straight RPC-1.00 female - RPC-1.85 female ≥ 19dB @ DC to 20 GHz<br />

≥ 17 dB @ 20 to 50 GHz<br />

≥ 14 dB @ 50 to 65 GHz<br />

19.2<br />

RPC-1.00<br />

SW5<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

217


Series RPC-1.00<br />

Tools<br />

Tools<br />

Torque Wrench<br />

xOrdering Number<br />

x01 W 021-000<br />

Remarks<br />

flat 6 mm - 35 Ncm torque for RPC-1.00<br />

136.5<br />

Gauge<br />

xOrdering Number<br />

x01 W 00S-000<br />

Remarks<br />

compatible to male connectors for RPC-1.00<br />

incl. gauge block<br />

ø10<br />

x01 W 00K-000<br />

compatible to female connectors for RPC-1.00<br />

incl. gauge block<br />

30<br />

32.2<br />

ø10<br />

SW6<br />

218<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Series RPC-1.00<br />

RPC-1.00<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

219


5<br />

6.6<br />

0.9<br />

1.5<br />

50 Ohm<br />

microstrip<br />

6.6<br />

4.7<br />

4.4<br />

3.1<br />

2.0<br />

extended scale<br />

2.7<br />

4.7<br />

vias (ø 0.4)<br />

to ground<br />

solder area<br />

10.3<br />

25.5<br />

ø 3.2<br />

14<br />

9.5<br />

2<br />

0.48<br />

11.3<br />

29.5<br />

ø 4.2<br />

12.7<br />

12.7<br />

solder area<br />

2.1<br />

extended scale<br />

2.8<br />

Please note when using footprints for SMD connectors:<br />

A wide variety of transmission line topologies and pcb-parameters<br />

like permittivity, substrate thickness and board-stack up are applied<br />

by customers. These parameters have a strong impact on the high<br />

frequency performance of the mounted connector.<br />

Bitte bei Verwendung von Footprints für SMD Steckverbinder<br />

beachten: Eine Vielzahl der PCB-Parameter, wie Substratstärke,<br />

dielektrische Leitfähigkeit und Board-to-Board-<br />

Anordnungen, werden anwendungsspezifisch vorgegeben.<br />

Diese Parameter beeinflussen die Hochfrequenz-Leistung<br />

des angebrachten Steckverbinders.<br />

The standard footprint layouts are not optimised to fit all of<br />

the possible board configurations regarding RF-performance.<br />

It represents a recommendation for optimum solderability of the<br />

connectors. In order to guarantee optimum high frequency properties<br />

of the connectors, an RF-analysis of the connector to board<br />

transition is recommended.<br />

Die Standard-Footprints erfüllen nicht alle möglichen Konfigurationsmöglichkeiten,<br />

sondern stellen eine Empfehlung<br />

für die optimale Lötbarkeit dar. Um die kundenspezifisch<br />

geforderten Hochfrequenzeigenschaften zu garantieren, wird<br />

eine HF-Analyse des Steckverbinders empfohlen.


Panel Piercings /PCB Layouts<br />

Features<br />

Panel Piercings<br />

PCB Layouts<br />

Index<br />

Panel Piercings<br />

Index


Panel Piercings / PCB Layouts<br />

1Panel 2MP change Piercings Footprint - / PCB Layouts<br />

MB 12<br />

MB 13<br />

3.2<br />

13.7<br />

16.2<br />

18.2<br />

16.2<br />

18.2<br />

MB 55<br />

MB 55a<br />

2.8<br />

2.8<br />

7.2<br />

8.6<br />

4.11<br />

8.6<br />

8.6<br />

8.6<br />

MB 55d<br />

MB 56<br />

2.8<br />

6<br />

2.76<br />

8.6<br />

6.5<br />

8.6<br />

222<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Panel Piercings / PCB Layouts<br />

MB 58<br />

MB 71<br />

2.4<br />

7.6<br />

8<br />

9.65 min.<br />

11.07 + 0.1<br />

11.07 + 0.1<br />

MB 82<br />

MB 92<br />

+0.1 9.3<br />

6.6 +0.05<br />

10.3<br />

+0.1<br />

MB 98<br />

MB 100<br />

+0.2<br />

3.2<br />

2.6<br />

4.1 +0.03<br />

18.2<br />

9.7<br />

14.2<br />

18.2<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

223<br />

Panel Piercings<br />

Index


Panel Piercings / PCB Layouts<br />

MB 106a<br />

MB 107<br />

2.6<br />

+0.1 8.2<br />

2.3<br />

12.7<br />

10.2<br />

+0.1<br />

12.7<br />

MB 208<br />

14<br />

9.5<br />

2<br />

0.48<br />

5<br />

2.8<br />

solder area<br />

2.1<br />

extended scale<br />

224<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Panel Piercings / PCB Layouts<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

225<br />

Panel Piercings<br />

Index


Index<br />

RPC-1.00<br />

01 CK 120-150 ....................................................51<br />

01 GK 0KS-000 ...................................................84<br />

01 K 101-270 E3 ...............................................216<br />

01 K 101-K20 D3 ........................................51, 217<br />

01 K 108-K00 D3 ......................................209, 217<br />

01 K 108-S00 D3 .......................................209, 217<br />

01 K 12S-000 D3 .........................................51, 105<br />

01 K 150-C10 D3 ........................................51, 105<br />

01 S 101-270 E3 ...............................................216<br />

01 S 101-K01 D3 .........................................51, 217<br />

01 S 101-K011 ............................................51, 111<br />

01 S 101-K012 ............................................51, 111<br />

01 S 101-K016 ............................................51, 111<br />

01 S 101-K02 D3 .........................................51, 217<br />

01 S 101-K20 D3 .........................................51, 217<br />

01 S 101-S20 D3 .........................................51, 217<br />

01 S 108-K00 D3 .......................................209, 217<br />

01 S 108-S00 D3 .......................................209, 217<br />

01 S 12S-000 D3 .........................................51, 105<br />

01 S 150-C10 D3 ........................................51, 105<br />

01 W 00K-000 .....................................84, 122, 218<br />

01 W 00S-000 .....................................84, 122, 218<br />

01 W 021-000 .....................................51, 119, 218<br />

RPC-2.92<br />

02 AS 102-K03 S3 ............................................113<br />

02 AS 102-K06 S3 ............................................113<br />

02 AS 102-K10 S3 ............................................113<br />

02 AS 102-K20 S3 ............................................113<br />

02 AS 102-K40 S3 ............................................113<br />

02 AS 122-K20 S3 ......................................77, 113<br />

02 AS 122-K40 S3 ......................................77, 113<br />

02 CK 100-150 ....................................................39<br />

02 CK 10A-150 ...................................................40<br />

02 CK 120-150 ....................................................41<br />

02 CK 200-150 ....................................................77<br />

02 K 108-K00 S3 .......................................189, 210<br />

02 K 108-S00 S3 .......................................189, 210<br />

02 K 109-K00 S3 .......................................189, 199<br />

02 K 109-S00 S3 .......................................189, 199<br />

02 K 118-K00 S3 ...............................................188<br />

02 K 118-S00 S3 ...............................................188<br />

02 K 119-K00 E3 .........................................69, 188<br />

02 K 119-S00 E3 ...............................................188<br />

02 K 121-000 S3 ...............................................184<br />

02 K 121-271 S3 ...............................................185<br />

02 K 121-K00 S3 ...............................................187<br />

02 K 121-K20 S3 .........................................39, 187<br />

02 K 12L-000 S3 ...................................39, 40, 104<br />

02 K 12S-000 S3 ...................................39, 40, 104<br />

02 K 12S-001 D3 .........................................41, 104<br />

02 K 150-055 S3 ...............................................109<br />

02 K 150-060 S3 ...............................................109<br />

02 K 150-075 S3 ...............................................109<br />

02 K 150-C10 S3 ..................................39, 40, 104<br />

02 K 150-G300 ............................................39, 106<br />

02 K 17R-001 D3 ..............................................104<br />

02 K 1P4-S00 S3 ........................................97, 190<br />

02 K 243-40M E3 ..............................................186<br />

02 K 421-271 S3 ...............................................185<br />

02 K 421-800 S3 ...............................................186<br />

02 K 521-S00 S3 ...............................................187<br />

02 K 526-800 S3 ...............................................186<br />

02 K 621-K00 S3 ...............................................187<br />

02 K 641-KH0 S3 ..............................................187<br />

02 KR 105-K00 S3 ....................................134, 189<br />

02 KR 105-S00 S3 ....................................134, 189<br />

02 KR 107-P00 S3 ....................................156, 189<br />

02 KR 121-K00 S3 ............................................187<br />

02 KR 121-S00 S3 ............................................187<br />

02 S 101-K015 ............................................41, 111<br />

02 S 101-K018 ............................................41, 111<br />

02 S 101-K040 ............................................41, 111<br />

02 S 101-K075 ............................................77, 111<br />

02 S 102-K075 ............................................77, 111<br />

02 S 108-K00 S3 .......................................188, 210<br />

02 S 108-S00 S3 .......................................188, 210<br />

02 S 109-K00 S3 .......................................189, 199<br />

02 S 109-S00 S3 .......................................189, 199<br />

02 S 118-K00 S3 ...............................................188<br />

02 S 118-S00 S3 ...............................................188<br />

02 S 119-K00 E3 ...............................................188<br />

02 S 119-S00 E3 .........................................69, 188<br />

02 S 121-000 S3 ...............................................184<br />

02 S 121-271 S3 ...............................................185<br />

02 S 121-K00 S3 ...............................................187<br />

02 S 121-K20 S3 ...............................................187<br />

02 S 121-S00 S3 ...............................................187<br />

02 S 121-S20 S3 .........................................39, 187<br />

02 S 12L-000 S3 ...................................39, 40, 104<br />

02 S 12S-000 S3 ................................... 39, 40, 104<br />

02 S 12S-001 D3 ........................................ 41, 104<br />

02 S 141-271 E4 ............................................... 185<br />

02 S 141-2W9 E4 .............................................. 185<br />

02 S 150-055 S3 ............................................... 109<br />

02 S 150-060 S3 ............................................... 109<br />

02 S 150-075 S3 ............................................... 109<br />

02 S 150-C10 S3 .................................. 39, 40, 104<br />

02 S 150-G300 ........................................... 39, 106<br />

02 S 17R-001 D3 ..............................................104<br />

02 S 1P4-S00 S3 ........................................ 97, 190<br />

02 S 422-S00 S3 ............................................... 187<br />

02 S 521-800 S3 ............................................... 186<br />

02 Z 001-2W9 D .................................................. 97<br />

02 Z 101-000 .................................................... 186<br />

RPC-3.50<br />

03 AS 102-K03 S3 ............................................ 112<br />

03 AS 102-K06 S3 ............................................ 112<br />

03 AS 102-K10 S3 ............................................ 112<br />

03 AS 102-K20 S3 ............................................ 112<br />

03 AS 102-K30 S3 ............................................ 112<br />

03 AS 102-K40 S3 ............................................ 112<br />

03 AS 122-K20 S3 ...................................... 76, 112<br />

03 AS 122-K40 S3 ...................................... 76, 112<br />

03 CK 100-150 .................................................... 35<br />

03 CK 10A-150 ................................................... 36<br />

03 CK 120-150 .................................................... 37<br />

03 CK 200-150 .................................................... 76<br />

03 GK 0KS-000 ................................................... 82<br />

03 K 104-S00 S3 ......................................... 95, 178<br />

03 K 105-K00 S3 ......................................132, 176<br />

03 K 105-S00 S3 ....................................... 132, 176<br />

03 K 107-P00 S3 ....................................... 156, 177<br />

03 K 107-P20 S3 ................................. 31, 156, 177<br />

03 K 109-K00 S3 ......................................176, 200<br />

03 K 109-S00 S3 ....................................... 176, 200<br />

03 K 110-K01 S3 ......................................166, 177<br />

03 K 110-K21 S3 ..........................31, 32, 166, 177<br />

03 K 110-S01 S3 ....................................... 166, 177<br />

03 K 110-S21 S3 ........................... 31, 32, 166, 177<br />

03 K 121-000 S3 ............................................... 172<br />

03 K 121-271 S3 ............................................... 173<br />

03 K 121-272 S3 ............................................... 173<br />

03 K 121-K00 S3 ..............................................174<br />

03 K 121-K20 S3 ........................................35, 174<br />

03 K 128-K20 N3 ........................................67, 175<br />

03 K 128-S20 N3 ........................................67, 175<br />

03 K 12L-000 S3 ............................. 35, 36, 73, 104<br />

03 K 12S-000 S3 ............................. 35, 36, 73, 104<br />

03 K 12S-001 D3 ........................................37, 104<br />

03 K 150-055 S3 ............................................... 109<br />

03 K 150-060 S3 ............................................... 109<br />

03 K 150-075 S3 ............................................... 109<br />

03 K 150-C10 S3 ............................ 35, 36, 73, 104<br />

03 K 150-G300 ........................................... 35, 106<br />

03 K 159-K20 S3 ........................................73, 175<br />

03 K 159-S20 S3 ......................................... 73, 175<br />

03 K 17R-001 D3 .............................................. 104<br />

03 K 421-271 S3 ............................................... 173<br />

03 K 421-600 S3 ............................................... 173<br />

03 K 521-S00 S3 ............................................... 174<br />

03 K 706-S23 S3 ....................................... 147, 177<br />

03 K 719-S22 S3 ............................................... 177<br />

03 K 721-S23 S3 ............................................... 174<br />

03 K 728-S22 S3 ............................................... 175<br />

03 KR 105-K00 S3 .................................... 133, 176<br />

03 KR 105-S00 S3 .................................... 133, 176<br />

03 KR 107-P00 S3 .................................... 156, 177<br />

03 KR 121-K00 S3 ............................................ 174<br />

03 KR 121-S00 S3 ............................................ 174<br />

03 S 101-K015 ............................................ 37, 111<br />

03 S 101-K020 ............................................ 37, 111<br />

03 S 101-K038 ............................................ 37, 111<br />

03 S 101-K100 ............................................ 76, 111<br />

03 S 102-K100 ............................................ 76, 111<br />

03 S 104-S00 S3 ......................................... 95, 178<br />

03 S 105-K00 S3 ....................................... 132, 176<br />

03 S 105-S00 S3 ....................................... 132, 176<br />

03 S 107-P00 S3 ....................................... 156, 176<br />

03 S 107-P20 S3 ................................. 31, 156, 176<br />

03 S 109-K00 S3 ....................................... 175, 200<br />

03 S 109-S00 S3 ....................................... 175, 200<br />

03 S 110-K01 S3 ....................................... 166, 177<br />

03 S 110-K21 S3 ........................... 31, 32, 166, 177<br />

03 S 110-S01 S3 ....................................... 166, 177<br />

03 S 110-S21 S3 ........................... 31, 32, 166, 177<br />

03 S 121-000 S3 ............................................... 172<br />

03 S 121-271 S3 ............................................... 173<br />

03 S 121-272 S3 ............................................... 173<br />

03 S 121-K00 S3 ............................................... 174<br />

03 S 121-K20 S3 .............................................. 174<br />

03 S 121-S00 S3 .............................................. 174<br />

03 S 121-S20 S3 ........................................ 35, 174<br />

03 S 128-K20 N3 ........................................ 67, 175<br />

03 S 128-S20 N3 ........................................ 67, 175<br />

03 S 12L-000 S3 ............................. 35, 36, 73, 104<br />

03 S 12S-000 S3 ............................ 35, 36, 73, 104<br />

03 S 12S-001 D3 ........................................ 37, 104<br />

03 S 150-055 S3 ............................................... 109<br />

03 S 150-060 S3 ............................................... 109<br />

03 S 150-075 S3 ............................................... 109<br />

03 S 150-C10 S3 ............................ 35, 36, 73, 104<br />

03 S 150-G300 ........................................... 35, 106<br />

03 S 159-K20 S3 ........................................ 73, 175<br />

03 S 159-S20 S3 ........................................ 73, 175<br />

03 S 17R-001 D3 .............................................. 104<br />

03 S 422-S00 S3 .............................................. 174<br />

03 W 00K-000 ................. 35, 39, 82, 121, 179, 191<br />

03 W 00S-000 ................. 35, 39, 82, 121, 179, 191<br />

03 W 021-000 ..... 35, 36, 37, 39, 40, 41, 43, 44, 45<br />

.................... 47, 48, 49, 73, 119,179, 191, 201, 211<br />

03 Z 001-272 D ................................................... 95<br />

RPC-SL, 26.5 GHz<br />

04 K 529-K00 S3 ................................................ 95<br />

04 W 021-000 ....................................... 95, 98, 119<br />

RPC-N, 50 Ω<br />

05 AS 102-K03 S3 ............................................ 112<br />

05 AS 102-K06 S3 ............................................ 112<br />

05 AS 102-K10 S3 ............................................ 112<br />

05 AS 102-K20 S3 ............................................ 112<br />

05 AS 102-K30 S3 ............................................ 112<br />

05 AS 102-K40 S3 ............................................ 112<br />

05 AS 122-K20 S3 ...................................... 74, 112<br />

05 AS 122-K40 S3 ...................................... 74, 112<br />

05 CK 100-150 ................................................... 15<br />

05 CK 10A-150 ................................................... 16<br />

05 CK 120-150 ................................................... 17<br />

05 CK 200-150 ................................................... 74<br />

05 DS 121-K00 S3 ............................................ 134<br />

05 GK 0KS-000 ................................................... 78<br />

05 K 104-S00 S3 ........................................ 95, 135<br />

05 K 106-K00 S3 ...................................... 130, 148<br />

05 K 106-K20 S3 ................................ 23, 130, 148<br />

05 K 106-S00 S3 ...................................... 129, 148<br />

05 K 107-P00 S3 ...................................... 132, 156<br />

05 K 121-000 S3 ............................................... 128<br />

05 K 121-271 S3 ............................................... 128<br />

05 K 121-272 S3 ............................................... 128<br />

05 K 121-273 S3 ............................................... 128<br />

05 K 121-K00 S3 .............................................. 129<br />

05 K 121-K20 S3 ........................................ 15, 129<br />

05 K 12L-000 S3 ................................... 15, 16, 102<br />

05 K 12S-000 S3 ............................ 15, 16, 17, 102<br />

05 K 132-K00 S3 .............................................. 130<br />

05 K 132-S00 S3 .............................................. 130<br />

05 K 150-010 S3 ............................................... 102<br />

05 K 150-055 S3 ............................................... 109<br />

05 K 150-060 S3 ............................................... 109<br />

05 K 150-075 S3 ............................................... 109<br />

05 K 150-C10 S3 .................................. 15, 16, 102<br />

05 K 150-G300 ........................................... 15, 106<br />

05 K 151-K00 S3 .............................................. 132<br />

05 K 151-K20 S3 ........................................ 59, 132<br />

05 K 151-S00 S3 .............................................. 132<br />

05 K 160-K50 D3 ........................................ 55, 131<br />

05 K 160-S50 D3 .............................................. 131<br />

05 K 1P4-S00 S3 ........................................ 97, 135<br />

05 K 432-K00 S3 .............................................. 131<br />

05 K 432-S00 S3 .............................................. 130<br />

05 K 521-271 S3 ............................................... 128<br />

05 K 521-272 S3 ............................................... 128<br />

05 K 521-273 S3 ............................................... 128<br />

05 K 521-K00 S3 .............................................. 129<br />

05 S 101-K026 ............................................ 17, 110<br />

05 S 101-K033 ............................................ 17, 110<br />

05 S 101-K061 ............................................ 17, 110<br />

05 S 101-K100 ............................................ 74, 110<br />

05 S 102-K100 ............................................ 74, 110<br />

05 S 104-S00 S3 ........................................ 95, 135<br />

05 S 106-K00 S3 ...................................... 129, 148<br />

05 S 106-S00 S3 ...................................... 129, 147<br />

05 S 106-S20 S3 ................................ 23, 129, 147<br />

05 S 107-P00 S3 ...................................... 132, 156<br />

05 S 121-000 S3 ............................................... 128<br />

05 S 121-271 S3 ............................................... 128<br />

05 S 121-272 S3 ............................................... 128<br />

05 S 121-273 S3 ............................................... 128<br />

05 S 121-K00 S3 .............................................. 129<br />

05 S 121-K20 S3 .............................................. 129<br />

226<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


Index<br />

05 S 121-S00 S3 ...............................................129<br />

05 S 121-S20 S3 .........................................15, 129<br />

05 S 12L-000 S3 ...................................15, 16, 102<br />

05 S 12S-000 S3 .............................15, 16, 17, 102<br />

05 S 132-K00 S3 ...............................................130<br />

05 S 132-S00 S3 ...............................................130<br />

05 S 150-010 S3 ...............................................102<br />

05 S 150-055 S3 ...............................................109<br />

05 S 150-060 S3 ...............................................109<br />

05 S 150-075 S3 ...............................................109<br />

05 S 150-C10 S3 ...................................15, 16, 102<br />

05 S 150-G300 ............................................15, 106<br />

05 S 151-K00 S3 ...............................................131<br />

05 S 151-S00 S3 ...............................................131<br />

05 S 151-S20 S3 .........................................59, 131<br />

05 S 160-K50 D3 ...............................................131<br />

05 S 160-S50 D3 .........................................55, 131<br />

05 S 1P4-S00 S3 .........................................97, 135<br />

05 S 432-K00 S3 ...............................................130<br />

05 S 432-S00 S3 ...............................................130<br />

05 W 00K-000 ...........15, 19, 78, 79, 120, 136, 141<br />

05 W 00S-000 ...............................15, 78, 120, 136<br />

RPC-TNC<br />

06 CK 100-150 ....................................................23<br />

06 CK 10A-150 ...................................................24<br />

06 GK 0KS-000 ...................................................80<br />

06 K 107-P20 S3 .......................................147, 157<br />

06 K 121-000 S3 ...............................................146<br />

06 K 121-K20 S3 .........................................23, 146<br />

06 K 12L-000 S3 ...................................23, 24, 103<br />

06 K 12S-000 S3 ...................................23, 24, 103<br />

06 K 132-K00 S3 ...............................................147<br />

06 K 132-S00 S3 ...............................................147<br />

06 K 150-C10 S3 ..................................23, 24, 103<br />

06 K 150-G300 ..................................................106<br />

06 S 107-P20 S3 .......................................147, 157<br />

06 S 121-000 S3 ...............................................146<br />

06 S 121-002 S3 ...............................................146<br />

06 S 121-K20 S3 ...............................................146<br />

06 S 121-S20 S3 .........................................23, 146<br />

06 S 12L-000 S3 ...................................23, 24, 103<br />

06 S 12S-000 S3 ...................................23, 24, 103<br />

06 S 132-K00 S3 ...............................................147<br />

06 S 132-S00 S3 ...............................................147<br />

06 S 150-C10 S3 ...................................23, 24, 103<br />

06 S 150-G300 ..................................................106<br />

06 W 00K-000 .....................................80, 120, 149<br />

06 W 00S-000 .....................................80, 120, 149<br />

06 W 021-000 ...............................23, 24, 119, 149<br />

RPC-7<br />

07 AP 122-P20 S3 .......................................75, 112<br />

07 AP 122-P40 S3 .......................................75, 112<br />

07 B 003-000 ....................................................159<br />

07 B 003-010 ....................................................159<br />

07 CK 100-150 ....................................................27<br />

07 CK 10A-150 ...................................................28<br />

07 CK 120-150 ....................................................29<br />

07 CK 200-150 ....................................................75<br />

07 GK 0KS-000 ...................................................81<br />

07 P 101-P034 ............................................29, 110<br />

07 P 101-P041 ............................................29, 110<br />

07 P 101-P068 ............................................29, 110<br />

07 P 101-P100 ............................................75, 110<br />

07 P 102-P100 ............................................75, 110<br />

07 P 104-S00 S3 .........................................95, 158<br />

07 P 110-K20 S3 .................................31, 157, 166<br />

07 P 110-S20 S3 .................................31, 157, 166<br />

07 P 121-000 S3 ...............................................154<br />

07 P 121-000/21 ...............................................159<br />

07 P 121-271 S3 ...............................................154<br />

07 P 121-272 S3 ...............................................154<br />

07 P 121-273 S3 ...............................................154<br />

07 P 121-P00 S3 ...............................................156<br />

07 P 12L-000 S3 ...................................27, 28, 103<br />

07 P 12S-000 S3 .............................27, 28, 29, 103<br />

07 P 132-K00 S3 ...............................................157<br />

07 P 132-S00 S3 ...............................................157<br />

07 P 150-010 S3 ...............................................103<br />

07 P 150-C10 S3 ...................................27, 28, 103<br />

07 P 150-G300 ............................................27, 106<br />

07 P 151-K00 S3 ...............................................157<br />

07 P 151-S00 S3 ...............................................157<br />

07 P 1P4-S00 S3 .........................................97, 158<br />

07 P 421-500 S3 ...............................................155<br />

07 P 422-500 S3 ...............................................155<br />

07 W 001-000 ...............................27, 81, 121, 159<br />

07 W 021-000 .....27, 28, 29, 31, 32, 119, 159, 167<br />

07 W 031-000 .....................................27, 119, 159<br />

RPC-1.85<br />

08 AS 102-K03 S3 ............................................ 113<br />

08 AS 102-K06 S3 ............................................ 113<br />

08 AS 102-K10 S3 ............................................ 113<br />

08 AS 102-K20 S3 ............................................ 113<br />

08 AS 102-K40 S3 ............................................ 113<br />

08 CK 100-150 .................................................... 47<br />

08 CK 10A-150 ................................................... 48<br />

08 CK 120-150 .................................................... 49<br />

08 GK 0KS-000 ................................................... 83<br />

08 K 118-K00 S3 ..............................................209<br />

08 K 118-S00 S3 ............................................... 209<br />

08 K 121-270 S3 ............................................... 206<br />

08 K 121-271 S3 ............................................... 206<br />

08 K 121-2W7 S3 ..............................................206<br />

08 K 121-K00 S3 ..............................................208<br />

08 K 121-K20 S3 ........................................47, 208<br />

08 K 12L-000 S3 ................................... 47, 48, 105<br />

08 K 12S-000 S3 ............................. 47, 48, 49, 105<br />

08 K 150-C10 S3 ..................................47, 48, 105<br />

08 K 150-G300 ................................................. 107<br />

08 K 421-270 S3 ............................................... 206<br />

08 K 421-271 S3 ............................................... 206<br />

08 K 421-2W7 S3 ..............................................206<br />

08 K 521-800 S3 ............................................... 207<br />

08 K 641-KH0 S3 ..............................................208<br />

08 S 101-271 D ................................................. 206<br />

08 S 101-K013 ............................................ 49, 111<br />

08 S 101-K014 ............................................ 49, 111<br />

08 S 101-K022 ............................................ 49, 111<br />

08 S 118-K00 S3 ............................................... 209<br />

08 S 118-S00 S3 ............................................... 209<br />

08 S 121-270 S3 ............................................... 206<br />

08 S 121-271 S3 ............................................... 206<br />

08 S 121-2W7 S3 .............................................. 206<br />

08 S 121-K00 S3 ............................................... 208<br />

08 S 121-K20 S3 ............................................... 208<br />

08 S 121-S00 S3 ............................................... 208<br />

08 S 121-S20 S3 ......................................... 47, 208<br />

08 S 12L-000 S3 ................................... 47, 48, 105<br />

08 S 12S-000 S3 ............................. 47, 48, 49, 105<br />

08 S 150-C10 S3 .................................. 47, 48, 105<br />

08 S 150-G300 ................................................. 107<br />

08 S 421-270 S3 ............................................... 206<br />

08 S 421-271 S3 ............................................... 206<br />

08 S 421-2W7 S3 .............................................. 206<br />

08 W 00K-000 .................43, 47, 83, 122, 201, 211<br />

08 W 00S-000 .................43, 47, 83, 122, 201, 211<br />

08 Z 101-000 .................................................... 207<br />

RPC-2.40<br />

09 CK 100-150 .................................................... 43<br />

09 CK 10A-150 ................................................... 44<br />

09 CK 120-150 .................................................... 45<br />

09 K 121-271 S3 ............................................... 196<br />

09 K 121-K00 S3 ..............................................199<br />

09 K 121-K20 S3 ........................................43, 199<br />

09 K 12L-000 S3 ................................... 43, 44, 105<br />

09 K 12S-000 S3 ............................. 43, 44, 45, 105<br />

09 K 150-C10 S3 ..................................43, 44, 105<br />

09 K 150-G300 ................................................. 107<br />

09 K 1P4-S00 S3 ........................................ 98, 198<br />

09 K 243-40M E3 ..............................................197<br />

09 K 421-271 S3 ............................................... 196<br />

09 S 101-K013 ............................................ 45, 111<br />

09 S 101-K015 ............................................ 45, 111<br />

09 S 101-K025 ............................................ 45, 111<br />

09 S 121-271 S3 ............................................... 196<br />

09 S 121-K00 S3 ............................................... 199<br />

09 S 121-K20 S3 ............................................... 199<br />

09 S 121-S00 S3 ............................................... 199<br />

09 S 121-S20 S3 ......................................... 43, 199<br />

09 S 12L-000 S3 ................................... 43, 44, 105<br />

09 S 12S-000 S3 ............................. 43, 44, 45, 105<br />

09 S 150-C10 S3 .................................. 43, 44, 105<br />

09 S 150-G300 ................................................. 107<br />

09 S 1P4-S00 S3 ........................................ 98, 198<br />

09 S 421-271 S3 ............................................... 196<br />

RPC-SP (BMA)<br />

10 CK 100-150 .................................................... 31<br />

10 CK 120-150 .................................................... 32<br />

10 K 12L-000 S3 ......................................... 31, 103<br />

10 K 12S-000 S3 ................................... 31, 32, 103<br />

10 K 150-C10 S3 ..................................31, 32, 103<br />

10 K 762-271 N3 ............................................... 164<br />

10 K 762-272 N3 ............................................... 164<br />

10 S 101-40M T3 .............................................. 165<br />

10 S 101-K005 ............................................ 32, 110<br />

10 S 101-K027 ............................................ 32, 110<br />

10 S 125-271 S3 ............................................... 164<br />

10 S 125-272 S3 ............................................... 164<br />

10 S 12L-000 S3 ......................................... 31, 103<br />

10 S 12S-000 S3 .................................. 31, 32, 103<br />

10 S 142-400 E3 ............................................... 165<br />

10 S 150-C10 S3 .................................. 31, 32, 103<br />

10 S 441-500 N3 .............................................. 165<br />

10 S 641-271 E3 ............................................... 164<br />

10 S 641-272 E3 ............................................... 164<br />

10 Z 001-K00 S ..................................... 31, 32, 167<br />

10 Z 001-S00 S ..................................... 31, 32, 167<br />

SMP<br />

19 AS 101-K03 E3 ............................................ 113<br />

19 AS 101-K06 E3 ............................................ 113<br />

19 AS 101-K10 E3 ............................................ 113<br />

19 AS 101-K20 E3 ............................................ 113<br />

19 AS 101-K30 E3 ............................................ 113<br />

19 CK 10A-150 ................................................... 69<br />

19 K 101-K20 D3 ................................................ 69<br />

19 K 10L-000 D3 ................................................. 69<br />

19 K 10S-000 D3 ................................................ 69<br />

19 K 150-C10 D3 ................................................ 69<br />

19 S 101-K20 D3 ................................................ 69<br />

19 S 101-S20 D3 ................................................ 69<br />

19 S 10L-000 D3 ................................................. 69<br />

19 S 10S-000 D3 ................................................ 69<br />

19 S 150-C10 D3 ................................................ 69<br />

QMA<br />

28 AS 102-K03 N3 ............................................ 114<br />

28 AS 102-K06 N3 ............................................ 114<br />

28 AS 102-K10 N3 ............................................ 114<br />

28 AS 102-K20 N3 ............................................ 114<br />

28 AS 102-K30 N3 ............................................ 114<br />

28 CK 100-150 ................................................... 67<br />

28 K 121-K20 N3 ................................................ 67<br />

28 K 12L-000 N3 ................................................ 67<br />

28 K 12S-000 N3 ................................................ 67<br />

28 K 150-C10 N3 ................................................ 67<br />

28 S 121-K20 N3 ................................................ 67<br />

28 S 121-S20 N3 ................................................ 67<br />

28 S 12L-000 N3 ................................................. 67<br />

28 S 12S-000 N3 ................................................ 67<br />

28 S 150-C10 N3 ................................................ 67<br />

SMA<br />

32 AS 102-K03 S3 ............................................ 114<br />

32 AS 102-K06 S3 ............................................ 114<br />

32 AS 102-K10 S3 ............................................ 114<br />

32 AS 102-K20 S3 ............................................ 114<br />

32 AS 102-K30 S3 ............................................ 114<br />

32 AS 102-K40 S3 ............................................ 114<br />

BNC, 50 Ω<br />

51 AS 103-K03 N4 ............................................ 116<br />

51 AS 103-K06 N4 ............................................ 116<br />

51 AS 103-K10 N4 ............................................ 116<br />

51 AS 103-K20 N4 ............................................ 116<br />

51 AS 103-K30 N4 ............................................ 116<br />

51 AS 103-K40 N4 ............................................ 116<br />

51 CK 100-150 ................................................... 59<br />

51 CK 10A-150 ................................................... 60<br />

51 K 121-K20 S3 ................................................ 59<br />

51 K 12L-000 S3 ........................................... 59, 60<br />

51 K 12S-000 S3 .......................................... 59, 60<br />

51 K 170-C10 S3 .......................................... 59, 60<br />

51 K 171-S00 N4 .............................................. 118<br />

51 S 121-S20 S3 ................................................ 59<br />

51 S 12L-000 S3 ........................................... 59, 60<br />

51 S 12S-000 S3 .......................................... 59, 60<br />

51 S 170-C10 S3 .......................................... 59, 60<br />

51 S 171-K00 N4 .............................................. 118<br />

N, 50 Ω<br />

53 AS 102-K01 N3 ............................................ 115<br />

53 AS 102-K02 N3 ............................................ 115<br />

53 AS 102-K03 N3 ............................................ 115<br />

53 AS 102-K06 N3 ............................................ 115<br />

53 AS 102-K10 N3 ............................................ 115<br />

53 AS 102-K20 N3 ............................................ 115<br />

53 AS 102-K30 N3 ............................................ 115<br />

53 AS 105-K03 N3 ............................................ 115<br />

53 AS 105-K06 N3 ............................................ 115<br />

53 AS 105-K10 N3 ............................................ 115<br />

53 AS 105-K20 N3 ............................................ 115<br />

53 AS 105-K30 N3 ............................................ 115<br />

53 AS 110-K03 N3 ............................................ 115<br />

53 AS 110-K06 N3 ............................................ 115<br />

53 AS 110-K10 N3 ............................................ 115<br />

53 AS 110-K20 N3 ............................................ 115<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com<br />

227<br />

Panel Piercings<br />

Index


Index<br />

53 AS 110-K30 N3 ............................................115<br />

53 AS 120-K03 N3 ............................................115<br />

53 AS 120-K06 N3 ............................................115<br />

53 AS 120-K10 N3 ............................................115<br />

53 AS 120-K20 N3 ............................................115<br />

53 AS 120-K30 N3 ............................................115<br />

53 K 34R-MSO N3 ............................................108<br />

53 K 36R-MSO N3 ............................................108<br />

53 QK 105-K00 S3 ............................................134<br />

53 QK 105-S00 S3 ............................................133<br />

53 QK 105-S20 S3 ......................................71, 134<br />

53 QK 12L-000 S3 ..............................................71<br />

53 QK 12S-000 S3 ..............................................71<br />

53 QK 150-C10 S3 ..............................................71<br />

53 QS 105-K00 S3 ............................................133<br />

53 QS 105-K20 S3 ......................................71, 133<br />

53 QS 105-S00 S3 ............................................133<br />

53 QS 12L-000 S3 ..............................................71<br />

53 QS 12S-000 S3 ..............................................71<br />

53 QS 150-C10 S3 ..............................................71<br />

53 S 171-K00 N3 ..............................................118<br />

53 S 173-K00 N3 ..............................................118<br />

53 S 34R-MSO N3 ............................................108<br />

53 S 36R-MSO N3 ............................................108<br />

53 W 009-000 15, 16, 17, 19, 20, 21, 119, 136, 141<br />

53Q CK 10A-150 .................................................71<br />

SMB, 50 Ω<br />

59 CK 100-150 ....................................................73<br />

59 Z 013-000 Z ...................................................73<br />

59 Z 014-000 Z ...................................................73<br />

7-16<br />

60 AS 105-K03 N1 ............................................117<br />

60 AS 105-K06 N1 ............................................117<br />

60 AS 105-K10 N1 ............................................117<br />

60 AS 105-K20 N1 ............................................117<br />

60 AS 105-K30 N1 ............................................117<br />

60 AS 105-K40 N1 ............................................117<br />

60 AS 110-K03 N1 ............................................117<br />

60 AS 110-K06 N1 ............................................117<br />

60 AS 110-K10 N1 ............................................117<br />

60 AS 110-K20 N1 ............................................117<br />

60 AS 110-K30 N1 ............................................117<br />

60 AS 110-K40 N1 ............................................117<br />

60 AS 120-K03 N1 ............................................117<br />

60 AS 120-K06 N1 ............................................117<br />

60 AS 120-K10 N1 ............................................117<br />

60 AS 120-K20 N1 ............................................117<br />

60 AS 120-K30 N1 ............................................117<br />

60 AS 120-K40 N1 ............................................117<br />

60 CK 100-150 ....................................................55<br />

60 CK 10A-150 ...................................................56<br />

60 CK 120-150 ....................................................57<br />

60 GK 0KS-000 ...................................................85<br />

60 K 101-K50 N1 ................................................55<br />

60 K 12L-12S D3 ...........................................55, 56<br />

60 K 12S-000 D3 .................................................57<br />

60 K 17R-C01 D3 ..........................................55, 56<br />

60 K 34R-MSO N3 ............................................108<br />

60 K 36R-MSO N3 ............................................108<br />

60 S 101-K050 ....................................................57<br />

60 S 101-K066 ....................................................57<br />

60 S 101-K150 ....................................................57<br />

60 S 101-K300 ....................................................57<br />

60 S 101-S50 N1 .................................................55<br />

60 S 12L-12S D3 ...........................................55, 56<br />

60 S 12S-000 D3 .................................................57<br />

60 S 17R-C01 D3 ..........................................55, 56<br />

60 S 34R-MSO N3 ............................................108<br />

60 S 36R-MSO N3 ............................................108<br />

60 W 00K-000 .............................................85, 123<br />

60 W 00S-000 .............................................85, 123<br />

74 S 101-K150 .................................................... 65<br />

74 S 121-S20 S3 ................................................. 63<br />

74 S 12L-000 S3 ........................................... 63, 64<br />

74 S 12S-000 S3 ........................................... 63, 64<br />

74 S 12S-001 S3 ................................................. 65<br />

74 S 150-C10 CS .......................................... 63, 64<br />

Cables<br />

L20-001-600 ....................................................... 93<br />

LU1-003-600 ...................................................... 93<br />

LU1-004-600 ...................................................... 93<br />

LU1-005-600 ...................................................... 93<br />

LU1-006-600 ...................................................... 93<br />

LU1-022-600 ...................................................... 93<br />

LU1-025-600 ...................................................... 93<br />

LU1-034-600 ...................................................... 93<br />

LU1-045-600 ...................................................... 93<br />

LU7-031-600 ...................................................... 93<br />

LU7-035-600 ...................................................... 93<br />

LU7-039-600 ...................................................... 93<br />

LU7-042-600 ...................................................... 93<br />

LU7-043-600 ...................................................... 93<br />

LU7-055-600 ...................................................... 93<br />

LU7-056-600 ...................................................... 93<br />

LU7-069-600 ...................................................... 93<br />

LU7-070-600 ...................................................... 93<br />

LU8-005-600 ...................................................... 93<br />

LU8-006-600 ...................................................... 93<br />

VA26-3.50m-3.50f-60 ......................................... 91<br />

VA26-Nm-Nm-60 ................................................ 91<br />

VA26-PC7-PC7-60 ............................................. 91<br />

VA26-TP-3.50-60 ................................................ 91<br />

VA26-TP-N-60 .................................................... 91<br />

VA26-TP-PC7-60 ................................................ 91<br />

VA26-TP-W-60 ................................................... 91<br />

VA40-TP-2.92-60 ................................................ 91<br />

VA40-TP-W-60 ................................................... 91<br />

VA41-TP-2.40-60 ................................................ 91<br />

VA41-TP-2.92-60 ................................................ 91<br />

VA41-TP-W-60 ................................................... 91<br />

VA50-TP-2.40-60 ................................................ 91<br />

VA75-Nm-Nm-60 ................................................ 91<br />

RPC-SL, 40 GHz<br />

P4 K 52A-K00 S3 ................................................ 97<br />

RPC-N, 75 Ω<br />

P5 CK 100-170 ................................................... 19<br />

P5 CK 10A-170 ................................................... 20<br />

P5 CK 120-170 ................................................... 21<br />

P5 DS 121-K01 CS ........................................... 141<br />

P5 GK 0KS-000 ................................................... 79<br />

P5 K 121-000 CS ..............................................140<br />

P5 K 121-K20 CS .............................................. 140<br />

P5 K 121-K20 S3 ................................................ 19<br />

P5 K 12L-000 S3 ................................... 19, 20, 102<br />

P5 K 12S-000 S3 ............................ 19, 20, 21, 102<br />

P5 K 150-C10 S3 .................................. 19, 20, 102<br />

P5 K 174-K20 CS ........................................ 63, 140<br />

P5 S 101-K031 ............................................ 21, 110<br />

P5 S 101-K150 ............................................ 21, 110<br />

P5 S 121-000 CS .............................................. 140<br />

P5 S 121-S20 CS .............................................. 140<br />

P5 S 121-S20 S3 ................................................ 19<br />

P5 S 12L-000 S3 ................................... 19, 20, 102<br />

P5 S 12S-000 S3 ............................ 19, 20, 21, 102<br />

P5 S 150-C10 S3 .................................. 19, 20, 102<br />

P5 S 174-S20 CS ........................................ 63, 140<br />

P5 W 00S-000 ............................... 19, 79, 120, 141<br />

BNC, 75 Ω<br />

71 AS 103-K03 N4 ............................................116<br />

71 AS 103-K06 N4 ............................................116<br />

71 AS 103-K10 N4 ............................................116<br />

71 AS 103-K20 N4 ............................................116<br />

71 AS 103-K30 N4 ............................................116<br />

71 AS 103-K40 N4 ............................................116<br />

F-Connectors<br />

74 CK 100-170 ....................................................63<br />

74 CK 10A-170 ...................................................64<br />

74 CK 120-170 ....................................................65<br />

74 K 121-K20 S3 .................................................63<br />

74 K 12S-001 S3 .................................................65<br />

74 S 101-K031 ....................................................65<br />

74 S 101-K100 ....................................................65<br />

228<br />

<strong>Rosenberger</strong> Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com


<strong>Rosenberger</strong><br />

Hochfrequenztechnik GmbH & Co. KG<br />

P.O.Box 1260<br />

D-84526 Tittmoning<br />

Tel.: + 49 - 86 84 -18 - 0<br />

Fax: + 49 - 86 84 -18 - 499<br />

E-Mail: info@rosenberger.de<br />

Web: www.rosenberger.com<br />

Certified by ISO /TS 16949 . ISO 9001 . ISO 14001<br />

Ordering No.<br />

info300TMCCat /5000/01-2010<br />

pA 125380<br />

© 01.2010 <strong>Rosenberger</strong><br />

Production Thewald Kommunikation

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!