GSG High Pressure Barrel Pump - The International EPD® System
GSG High Pressure Barrel Pump - The International EPD® System
GSG High Pressure Barrel Pump - The International EPD® System
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Functional unit<br />
<strong>The</strong> functional unit is 1 kW of rated hydraulic power at optimum efficiency.<br />
Composition of the product<br />
Material kg % 1) kg/kW 3)<br />
Cast iron 4'200 20% 2.80<br />
Alloyed / high alloyed<br />
steel<br />
16'675 79% 11.12<br />
Oil 192 1% 0.13<br />
Parts not included<br />
2)<br />
100 0% 0.07<br />
Total 21'167 100% 14.1<br />
1) By weight.<br />
2) Weight not included in assessment.<br />
3) Rated power.<br />
79% of the pump consists of alloyed and high alloyed<br />
steels, 20% of cast iron.<br />
<strong>The</strong> indicated quantity of oil refers to the initial fill of<br />
the pump, the oil is replaced every second year after<br />
installation.<br />
Remaining components such as paints and seals<br />
amount to less than 1% of the total weight and have<br />
as such been omitted.<br />
Material consumption during life cycle per pump 1) (material balance sheet)<br />
Procurement 2) Manufacturing at Usage / end of life<br />
Non-renewable<br />
Sulzer<br />
resources kg kg/kW kg kg/kW kg kg/kW<br />
Steel (alloyed), casting<br />
3) 3)<br />
for pump 21 600 14.40 20 900 13.93 20 900 13.93<br />
for spare parts 860 0.57 830 0.55 830 0.55<br />
Oil 1 900 1.27 1 900 1.27 1 900 1.27<br />
Waste production (total) n.a. n.a. 1 220 0.81 23 630 15.75<br />
Hazardous waste n.a. n.a. 150 0.10 1 900 1.27<br />
Municipal waste n.a. n.a. 270 0.18 n.a. n.a.<br />
Recycling (total) n.a. n.a. 800 0.53 21 730 14.49<br />
metals (pump) n.a n.a 700 0.47 20 900 13.93<br />
metals (spare parts) n.a. n.a. 30 0.02 830 0.55<br />
others n.a. n.a. 70 0.05 n.a. n.a.<br />
Renewable resources kg kg/kW kg kg/kW kg kg/kW<br />
Wood (packaging) 370 0.25 360 0.25 360 360<br />
Water consumption 4) n.a. n.a. 30 700 20.47 n.a. n.a.<br />
n.a.: not available, values per kW related to 1 500 kW rated power.<br />
1)<br />
Material resources related to supply of energy to site are not considered.<br />
2) Covers all resources procured during the life cycle by Sulzer, including the oil used to operate the pump.<br />
3)<br />
Machining during the manufacturing produces recyclable waste of around 4% by mass of the metals bought in.<br />
4)<br />
In manufacturing: used for testing purposes.<br />
page 2/6