HP ProLiant DL180 Generation 6 (G6) - Hewlett Packard
HP ProLiant DL180 Generation 6 (G6) - Hewlett Packard
HP ProLiant DL180 Generation 6 (G6) - Hewlett Packard
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
QuickSpecs <strong>HP</strong> <strong>ProLiant</strong> <strong>DL180</strong> <strong>Generation</strong> 6 (<strong>G6</strong>)<br />
Storage<br />
SSD<br />
200GB 3G SATA MLC SFF<br />
SSD<br />
100GB 3G SATA MLC SFF<br />
SSD<br />
drive cage <strong>HP</strong> Smart Array P212/256 MB Controller<br />
<strong>HP</strong> Smart Array P410/256 MB Controller<br />
<strong>HP</strong> Smart Array P410/512 MB BBWC Controller<br />
<strong>HP</strong> Smart Array P410/512 MB FBWC Controller<br />
<strong>HP</strong> Smart Array P410/1G FBWC Controller<br />
<strong>HP</strong> Smart Array P812/1G FBWC Controller<br />
Up to 25 with 25<br />
drive cage<br />
SATA Hot Plug 3.5" Midline (MDL) Solid State Drives<br />
400GB 3G SATA MLC LFF<br />
SSD<br />
200GB 3G SATA MLC LFF<br />
SSD<br />
100GB 3G SATA MLC LFF<br />
SSD<br />
Quantity<br />
Supported<br />
Up to 8 with 8<br />
drive cage<br />
SAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives<br />
1.0TB 6G SAS 7.2K<br />
500GB 6G SAS 7.2K<br />
Quantity<br />
Supported<br />
Up to 8 with 8<br />
drive cage<br />
Up to 25 with 25<br />
drive cage<br />
SAS Hot Plug LFF (3.5-inch) Midline (MDL) Drives<br />
3TB 6G SAS 7.2K<br />
2TB 6G SAS 72K<br />
1TB 6G SAS 7.2K<br />
Quantity<br />
Supported<br />
Up to 8 with 8<br />
drive cage<br />
1-25 <strong>HP</strong> Smart Array P212/256 MB Controller<br />
<strong>HP</strong> Smart Array P410/256 MB Controller<br />
<strong>HP</strong> Smart Array P410/512 MB BBWC Controller<br />
<strong>HP</strong> Smart Array P410/512 MB FBWC Controller<br />
<strong>HP</strong> Smart Array P410/1G FBWC Controller<br />
<strong>HP</strong> Smart Array P812/1G FBWC Controller<br />
<strong>HP</strong> Smart Array Hot Plug Advance Pack for B110i<br />
Position<br />
Supported Controller<br />
1-8 <strong>HP</strong> Smart Array P410/256 MB Controller<br />
<strong>HP</strong> Smart Array P410/512 MB BBWC Controller<br />
<strong>HP</strong> Smart Array P410/512 MB FBWC Controller<br />
<strong>HP</strong> Smart Array P410/1G FBWC Controller<br />
<strong>HP</strong> Smart Array P812/1G FBWC Controller<br />
<strong>HP</strong> Smart Array P212/Zero Memory Controller<br />
<strong>HP</strong> Smart Array P212/256 MB Controller<br />
<strong>HP</strong> Smart Array B110i Hot Plug Advance Pack for B110i<br />
Position<br />
Supported Controller<br />
1-8 <strong>HP</strong> Smart Array P212/Zero Memory Controller<br />
<strong>HP</strong> Smart Array P212/256 MB Controller<br />
<strong>HP</strong> Smart Array P410/256 MB Controller<br />
<strong>HP</strong> Smart Array P410/512 MB BBWC Controller<br />
<strong>HP</strong> Smart Array P410/512 MB FBWC Controller<br />
<strong>HP</strong> Smart Array P410/1G FBWC Controller<br />
<strong>HP</strong> Smart Array P812/1G FBWC Controller<br />
<strong>HP</strong> Smart Array P800/512 BBWC Controller<br />
1-25 <strong>HP</strong> Smart Array P212/256 MB Controller<br />
<strong>HP</strong> Smart Array P410/256 MB Controller<br />
<strong>HP</strong> Smart Array P410/512 MB BBWC Controller<br />
<strong>HP</strong> Smart Array P410/512 MB FBWC Controller<br />
<strong>HP</strong> Smart Array P410/1G FBWC Controller<br />
<strong>HP</strong> Smart Array P812/1G FBWC Controller<br />
<strong>HP</strong> Smart Array P800/512 BBWC Controller<br />
Position<br />
Supported Controller<br />
1-8 <strong>HP</strong> Smart Array P212/Zero Memory Controller<br />
<strong>HP</strong> Smart Array P212/256 MB Controller<br />
<strong>HP</strong> Smart Array P410/256 MB Controller<br />
DA - 13248 North America — Version 53 — September 24, 2012 Page 45