09.01.2015 Views

TDS - Axson North America, Inc

TDS - Axson North America, Inc

TDS - Axson North America, Inc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RIM855/RIM905<br />

Reaction Injection Molding<br />

Technical Data Sheet<br />

Flexural Modulus 219,500 psi (1,500 mPa)<br />

Tg 255°F (124°C)<br />

PROCESSING CONDITIONS<br />

Part B contains fillers which tend to settle during storage; remix to ensure a homogeneous product. Part B may be<br />

remixed through the use of an agitator on a dispensing machine or by hand; after remixing be sure to protect the<br />

material from moisture contamination through the use of a qualified dry blanket like <strong>Axson</strong> <strong>North</strong> <strong>America</strong>’s dry gas<br />

blanket. Both parts (polyol and isocyanate) must be mixed at a temperature higher than 65°F (18.5°C) according to<br />

the mix ratio above. Casting must be conducted in molds free of any trace of moisture. For further information<br />

please consult AXSON’s technical staff or AXSON’s technical data sheet about ANCILLARY PRODUCTS.<br />

Prior to unsupported post cure: Once demolded, ensure that the part has obtained a rigid state prior to<br />

unsupported post cure. Example: 1/8 inch part from 158°F (70°C) silicone mold may be post cured without support<br />

roughly 4 minutes after demolding, whereas a 1/8 inch part from a room temperature silicone mold can be post<br />

cured without support roughly 6 minutes after demolding. The time required prior to unsupported post cure is<br />

dependent upon the mold temperature as well as the geometry of the part being fabricated.<br />

Optimum properties of the material are obtained after a 14 hour post cure at 176°F (80°C)<br />

STORAGE CONDITIONS<br />

Shelf life is 1 year (12) months when stored at 77°F (25°C) in original, unopened containers.<br />

HANDLING PRECAUTIONS<br />

Possibly irritating to the respiratory system and to skin. Always wear appropriate personal protection. Avoid<br />

fumes, use only in a well ventilated area. If skin contact occurs, wash immediately with soap and water; if<br />

irritation develops contact a physician. In the event of an eye splash, wash the contaminated eye with water for<br />

at least 15 minutes and immediately seek medical help. If ingested, contact a physician.<br />

Consult the MSDS for further information.<br />

GUARANTEE<br />

The information presented in this technical data sheet are based on results of tests conducted under precise conditions. It is the responsibility of<br />

the user to determine the suitability of AXSON products, under their own conditions, before commencing with application. AXSON refuses any<br />

guarantee concerning the compatibility of a product with any particular application. AXSON disclaims all responsibility for damage from any<br />

incident which results from the use of these products. The guarantee conditions are regulated by our general sale conditions.<br />

Page 2/2- Rev. 03 August 10, 2009<br />

AXSON NA USA AXSON GmbH AXSON IBERICA AXSON BRASIL AXSON SHANGHAI AXSON JAPAN<br />

1611 Hults Drive Dietzenbach Barcelona Sao Paulo Shanghai OKAZAKI CITY<br />

Eaton Rapids, MI Tél. (++49) 60 74 407110 Tel. (++34) 93 225 16 20 Tel. (++55) 11 5687 7331 Tel. (++86)-58 68 30 37 Tel.(++81) 564 26 2591<br />

48827<br />

Tel. (517) 663-8191 AXSON Italie AXSON UK Limited AXSON MEXICO AXSON France<br />

Fax (517) 663-0523 Saronno Newmarket Mexico DF Cergy<br />

Email : info@axson-na.com Tel. (++39) 02 96 70 23 36 Tel. (++44) 1638 660 062 Tel. (++52) 55 5264 49 22 Tél. (++33) 1 34 40 34 60<br />

Email : axson@axson.fr

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!