TBS transient and lightning protection <strong>system</strong>s<br />

<strong>OBO</strong> <strong>system</strong> <strong>solutions</strong><br />

<strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s<br />

Completely installed. Fully protected.<br />

Photovoltaic <strong>system</strong>s intelligently<br />

protected and safely installed


<strong>OBO</strong> offers a carefully coordinated<br />

product range which covers the entire<br />

installation of a <strong>photovoltaic</strong> <strong>system</strong>.<br />

This begins with external lightning<br />

protection, with practical interception<br />

and arrestor <strong>system</strong>s, equipotential<br />

bonding <strong>system</strong>s and<br />

I<br />

I<br />

comprehensive <strong>solutions</strong> <strong>for</strong> surge<br />

protection, and is rounded off by all<br />

components which you need <strong>for</strong> a<br />

clean and safe installation on and in<br />

the building – from the mesh cable<br />

trays through cable channels to fire<br />

protection <strong>system</strong>s.<br />

I<br />

Questions on the subject?<br />

Customer Service Germany<br />

Tel. 0 23 73/89-15 00<br />

Fax 0 23 73/89-77 77<br />

E-mail info@obo-betterman.com<br />

I<br />

I


Surge protection <strong>system</strong>s<br />

Equipotential bonding <strong>system</strong>s<br />

Cable support <strong>system</strong>s<br />

Lightning protection<br />

<strong>system</strong>s<br />

Fire protection <strong>system</strong>s Connection and<br />

fastening <strong>system</strong>s<br />

I<br />

Hagebaumarkt I Neuenrade<br />

PV-Anlage I Padua<br />

I<br />

Waste treatment plant I Heidenheim<br />

I


Safeguard investments and property<br />

Principles and facts<br />

All-round protection <strong>for</strong> the time without sun<br />

These days <strong>photovoltaic</strong> <strong>system</strong>s are<br />

run <strong>for</strong> profit. Due to plant size, local<br />

global radiation, etc. cost effectiveness<br />

and amortisation are both calcu-<br />

Risk from lightning strikes<br />

Total of all lightning flashes in Germany per year<br />

2,750,000<br />

2,750,000<br />

2,750,000<br />

2,750,000<br />

2,750,000<br />

2,750,000<br />

2,750,000<br />

2,750,000<br />

Current standards and guidelines<br />

4<br />

2,088,279<br />

1,570,416<br />

2,281,377<br />

2,013,546<br />

lated. Damage to the <strong>photovoltaic</strong><br />

<strong>system</strong> through lightning or surge impulses<br />

reduces the balance of returns<br />

and prolongs the amortisation period.<br />

1,927,941<br />

1,752,455<br />

2,660,000<br />

2,484,791<br />

2,100,000<br />

2000 2001 2002 2003 2004 2005 2006 2007 2008<br />

IEC/EN 62305-1:2006 Lightning protection – general principles<br />

IEC/EN 62305-2:2006 Lightning protection – risk management<br />

Lightning flashes in Germany 2007<br />

Total lightning flashes:<br />

2,662,409<br />

Strongest day:<br />

21.06.2007 I 162,139<br />

Strongest week:<br />

Week 21 I 452,160<br />

Strongest month:<br />

June I 1,023,778<br />

www.blids.de<br />

IEC/EN 62305-3:2006 Lightning protection – protection of structural facilities and<br />

persons<br />

IEC/EN 62305-4:2006 Lightning protection – electrical and electronic <strong>system</strong>s<br />

in structural facilities<br />

IEC/EN 61643-11:2007 Surge protection devices <strong>for</strong> use in low-voltage installations<br />

IEC 60364-7-712:2006 Requirements <strong>for</strong> solar <strong>photovoltaic</strong> (PV) power supply <strong>system</strong>s<br />

VdS 2010 Risk-oriented lightning and surge protection<br />

Guideline of the German general insurance association


Combi arrester against lightning and surges <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s<br />

The <strong>photovoltaic</strong> <strong>system</strong> also requires<br />

safety measures: Effective<br />

protection against lightning strikes<br />

and electrical surges is extremely<br />

necessary in order that the facil-<br />

ity doesn’t experience any nasty<br />

surprises even be<strong>for</strong>e the amortisation<br />

period has ended. Added<br />

to that, regional building regulations<br />

as well as property insurers<br />

under the VdS directive <strong>for</strong> certain<br />

buildings and plants require that<br />

lightning and electrical surge protection<br />

is in place.<br />

Protection range according to the lightning protection ball characteristics IEC/EN 62305-3<br />

Lightning protection class I II III IV<br />

R (m) (lightning protection sphere) 20 30 45 60<br />

d = distance of interception <strong>system</strong> (m) p = penetration depth (m)<br />

2 0.03 0.02 0.01 0.01<br />

3 0.06 0.04 0.03 0.02<br />

4 0.10 0.07 0.04 0.04<br />

5 0.16 0.10 0.07 0.05<br />

10 0.64 0.42 0.28 0.21<br />

15 1.46 0.95 0.63 0.47<br />

20 2.68 1.72 1.13 0.84<br />

Interception <strong>system</strong> including solar module<br />

Use of interception rods according to protection angle characteristics IEC/EN 62305-3 and lightning sphere characteristics.<br />

Beware of shadow!<br />

5


Protect the heart of the <strong>photovoltaic</strong> <strong>system</strong><br />

Our <strong>system</strong> <strong>solutions</strong> <strong>for</strong> the protection of the inverter<br />

Buildings without external lightning protection<br />

Surge protection <strong>for</strong> the current inverter<br />

– the heart of the <strong>system</strong> – is<br />

particularly important on buildings<br />

without external lightning protection.<br />

A protection <strong>system</strong> should cover<br />

6<br />

Location Description U DC max Type Article No. Figure<br />

A<br />

B<br />

C<br />

3-pin complete unit 1,000 V V20-C/3-PH-1000 509460 8<br />

2-pin complete unit 1,000 V V20-C/2-PH-1000 509461 7<br />

System solution in housing 1,000 V VG-C/DC-PH-MS 1000 5088 69 1<br />

System solution in housing with<br />

MC 4 connector<br />

745 V VG-C/DC-PH 550 5088 69 0<br />

230 V (L, N, PE) V20-C/1+NPE-280 509465 0<br />

230/400 V (L1, L2, L3, N, PE) V20-C/3+NPE-280 5094 656<br />

Equipotential bonding rail<br />

VDE-tested<br />

all at-risk lines that are connected to<br />

the current inverter. The DC surge<br />

arrester (protection circuits up to<br />

1,000 V DC available) must be<br />

matched to the maximum no-load<br />

External lightning protection is not necessary or required. A type 2 surge protection is sufficient.<br />

Solar module Power inverter<br />

DC<br />

protection<br />

PAS<br />

AC<br />

protectio<br />

Main distribution<br />

voltage of the solar module. The<br />

maximum no-load voltage is typically<br />

up to 20% above the indicated noload<br />

voltage (U OC STC ).<br />

Energy<br />

network<br />

tributor box with protection device is greater<br />

than 10 m line length<br />

1801 VDE 5015 650<br />

Note: An equipotential qu bonding between the metallic PV framework and the main m equipotential bonding g should be created.<br />

*<br />

-


Buildings with external lightning protection<br />

In buildings with external lightning<br />

protection, a direct lightning strike<br />

into the PV module must be prevented<br />

by the lightning protection <strong>system</strong>.<br />

The high lightning current cre-<br />

Solar module Interception<br />

rod<br />

Power inverter<br />

ates a strong magnetic field, which<br />

induces overvoltage in the electrical<br />

components. Lightning and surge<br />

protection <strong>for</strong> the current inverter –<br />

the heart of the <strong>system</strong> – is particu-<br />

DC protection AC protection<br />

PAS<br />

larly important in this application. A<br />

protection <strong>system</strong> should cover all<br />

at-risk lines that are connected to the<br />

current inverter.<br />

The distance between the lightning protection and the <strong>photovoltaic</strong> <strong>system</strong> (normally 0.5 m–1 m) cannot be maintained<br />

(e.g. metal roof).<br />

Main distribution<br />

Location Description U DC max Type Article No. Figure<br />

A<br />

B<br />

C<br />

�<br />

3-pin complete unit 900 V V25-B+C/3-PH900 5097 447<br />

2-pin complete unit 900 V V25-B+C/2-PH900 5097 45 7<br />

3-pin complete unit 600 V V50-B+C/3-PH600 5093 62 3<br />

2-pin complete unit 600 V V50-B+C/2-PH600 5093 628<br />

System solution in housing 900 V VG-BC/DC PH-MS 900 5088 692<br />

System solution in housing 600 V VG-BC/DC PH-MS 600 5088 693<br />

230 V (L, N, PE) V 25-B+C/1+NPE 5094 45 7<br />

230/400 V (L1, L2, L3, N, PE) V 50-B+C/3+NPE 5093 65 4<br />

Equipotential bonding rail<br />

VDE-tested<br />

Connectors capable of withstanding lightning<br />

current will be implemented with a minimum of<br />

16 mm 2 (copper).<br />

1801 VDE 5015 650<br />

Note: Should iit be possible to maintain the distance between w the lightning protection and the <strong>photovoltaic</strong> <strong>system</strong>, then the surge su protection<br />

measures on page 6 should be sufficient.<br />

7


Be on the safe side<br />

Lightning and surge protection<br />

<strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s<br />

The outward signs of a <strong>photovoltaic</strong> <strong>system</strong> are the solar modules. With its comprehensive range, <strong>OBO</strong><br />

ensures the integration of the <strong>system</strong> into the entire building installation. With our transient and lightning<br />

protection products, we offer everything that you need <strong>for</strong> a clean installation.<br />

Combi arrester <strong>for</strong> main power<br />

supply<br />

Through the combined lightning current<br />

and surge arrester (class 1+2) a<br />

lightning current equipotential bonding<br />

according to EN 62305 as well<br />

as surge protection according to IEC<br />

60364-5-53 can be conducted.<br />

Lightning current arresters must<br />

be integrated into the equipotential<br />

bonding in a way which makes<br />

them capable of withstanding<br />

lightning current (min.<br />

16 mm 2 copper).<br />

8


Photovoltaic generator laminated on a metal roof<br />

Suitable <strong>solutions</strong><br />

Modular and installation-ready <strong>solutions</strong> <strong>for</strong> DC and AC <strong>system</strong>s:<br />

Lightning and surge protection safeguards property and increases availability.<br />

Protected <strong>photovoltaic</strong><br />

generator<br />

If the <strong>photovoltaic</strong> module lies within<br />

the protection range of the lightning<br />

interceptor, and if the distance to the<br />

lightning protection <strong>system</strong> is maintained,<br />

then instead of the combination<br />

arrester, a type 2 surge protection<br />

device may also be used.<br />

If the distance between the <strong>photovoltaic</strong><br />

plant and the lightning protection<br />

<strong>system</strong> cannot be maintained<br />

(e.g. with a metal roof), the <strong>system</strong>s<br />

should be connected with at least<br />

16 mm 2 (copper).<br />

At the building entry (LPZ 0-1) possible<br />

partial lightning currents should<br />

be dealt with by the appropriate combi<br />

arrester (type 1 or types 1+2). <strong>OBO</strong><br />

offers suitable combination lightning<br />

arrestors <strong>for</strong> DC applications.<br />

9


The perfect choice<br />

KTS <strong>system</strong>s <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s<br />

Around the world, the <strong>OBO</strong> brand stands <strong>for</strong> certified quality and <strong>for</strong> innovative products developed and<br />

manufactured in-house. No matter whether you are laying power cables, outfitting industrial buildings<br />

with complete cable support <strong>system</strong>s or installing <strong>photovoltaic</strong> <strong>system</strong>s – with <strong>OBO</strong> products, you’re<br />

always in safe hands.<br />

<strong>OBO</strong> offers you all possibilities<br />

A comprehensive range of practical,<br />

more efficient and easier-to-mount<br />

cable support <strong>system</strong>s as the perfect<br />

solution to any installation task.<br />

We offer you a broad spectrum of<br />

materials and surfaces <strong>for</strong> operational<br />

areas, both indoors and out, as well as<br />

a high mechanical robustness against<br />

chemical influences by means of our<br />

epoxy-polyester coating.


For many years, customers from industry and from the plant construction<br />

and building engineering sectors have trusted the experience and know-how<br />

of the globally active <strong>OBO</strong> <strong>Bettermann</strong> group.<br />

For universal application, <strong>OBO</strong> provides<br />

tailor-made cable support <strong>system</strong>s<br />

in its range. From low voltage<br />

current transferral through to energy<br />

supply. Available in diverse heights,<br />

widths and in varying surface and<br />

material quality.<br />

<strong>OBO</strong> offers a variety of covers <strong>for</strong> all<br />

<strong>system</strong>s, to provide additional protection<br />

<strong>for</strong> pipes from the effects of<br />

weather and mechanical demands.<br />

11


A long-lasting choice<br />

Fire protection <strong>solutions</strong> <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s<br />

There is a high level of requirement attached to the fire safety of installations in modern buildings. <strong>OBO</strong> offers<br />

a complete product range <strong>for</strong> fire safety-conscious electronic installation. Be it sealing <strong>system</strong>s, fire protection<br />

ducts or installation <strong>system</strong>s <strong>for</strong> security-relevant plants – this entire one-stop package fulfils all prevention<br />

goals as required by building regulations: to hinder the spreading of fire, to secure emergency routes and to<br />

maintain function. In this way, it is not only the <strong>photovoltaic</strong> <strong>system</strong> that is protected, but also the entire<br />

building.<br />

12


Fire protection seminars<br />

<strong>OBO</strong> offers an abundance of seminars<br />

<strong>for</strong> electronic installation engineers,<br />

planners and architects. The complex<br />

areas of fire protection and surge protection<br />

especially invite clarification<br />

and number among the classic seminar<br />

subjects.<br />

Visit the <strong>OBO</strong> seminars and let yourself<br />

be brought right up to date.<br />

Safe cable routing<br />

When cables penetrate the fire protection walls of <strong>photovoltaic</strong> <strong>system</strong>s, or<br />

when they need to be installed in escape routes, then special measures are<br />

required. These apply especially in public buildings. <strong>OBO</strong> offers here a comprehensive<br />

range from cable compartmentalisation through to escape route<br />

installation.<br />

<strong>OBO</strong> fire protection offensive: simply<br />

in<strong>for</strong>m


A clean choice<br />

Installation <strong>solutions</strong><br />

<strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s<br />

Alongside the aspect of protection against lightning and electricity surges, the installation engineer finds themself<br />

faced with the task of installing the pipeline facility in accordance with architectural and static conditions.<br />

It is also here that the emphasis falls on the protection of the cables and pipes against damage, as well as the<br />

protection of the entire facility against moisture damage. <strong>OBO</strong> <strong>Bettermann</strong> is at your side with its fastening and<br />

fitting <strong>system</strong>s which have been established in the market <strong>for</strong> years.<br />

Diversity is the key<br />

Because of the number of different<br />

installation conditions,<br />

there are also constantly new<br />

demands made on the installation<br />

material.<br />

For use in direct sunlight, the<br />

UV-resistant <strong>system</strong>s serve extremely<br />

well, such as the Star-<br />

Quick clips in conjunction with<br />

steel armoured pipes or ribbon<br />

clips <strong>for</strong> wind-proof montage<br />

of lines, e.g. on cable support<br />

<strong>system</strong>s.<br />

Fastening elements from hotdip<br />

galvanised steel, stainless<br />

steel or aluminium are also<br />

available in a great variety of<br />

sizes.<br />

14


The installation of modern <strong>photovoltaic</strong> <strong>system</strong>s constantly presents the<br />

installation engineer with the task of laying the lines safely while con<strong>for</strong>ming<br />

to standards. The insertion of the energy lines in connection units<br />

such as the inverter or the counter unit is also a subject <strong>for</strong> discussion.<br />

It’s a question<br />

of combination<br />

With the <strong>OBO</strong> range of products,<br />

you can be sure you will always be<br />

equipped <strong>for</strong> any eventuality.<br />

The sealing of entries <strong>for</strong> inverter<br />

and distribution <strong>system</strong>s, which are<br />

exposed to the effects of weather,<br />

can be secured with the <strong>OBO</strong> cable<br />

glands of the V-TEC VM series (Protection<br />

class IP 68). The black-coloured<br />

types are recommended <strong>for</strong><br />

outdoor use as these ensure less<br />

UV radiation penetration.<br />

If you have too few entries in the inverter,<br />

or the screw connection is<br />

too large, these problems can be<br />

overcome by using the multi-way<br />

seal insert or the reducing seal insert.<br />

The multi-way seal inserts are<br />

especially useful with the smalldiameter<br />

<strong>photovoltaic</strong> lines.<br />

15


Surge protection<br />

Energy technology<br />

Lightning current and surge arrester <strong>for</strong> power supply <strong>system</strong> Photovoltaic<br />

16 TBS<br />

Type<br />

V50-B+C 3+NPE<br />

Complete = upper part and base<br />

Highest<br />

continuous<br />

voltage<br />

Version<br />

Pack. Weight Item No.<br />

V<br />

pcs kg/% pc<br />

280 3 + NPE 1 55.000 5093 65 4<br />

V 50-B+C/3+NPE: Combination arrester, lightning and surge arrester, Type 1+2 to DIN EN 61643-<br />

11 (B+C to VDE 0675 Part 6).<br />

• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)<br />

• Lightning current arresting capacity 12.5 kA (10/350) per pole and 50 kA (10/350) in total<br />

• Universally suitable <strong>for</strong> TN and TT <strong>system</strong>s<br />

• With new Multibase base with multi-connection terminals<br />

• Complete unit, consisting of cover and base, pre-mounted and ready <strong>for</strong> connection<br />

• Arrester, connectable with dynamic separation unit<br />

• With visual function display<br />

• Voltage protection level < 1,3 kV<br />

• Encapsulated, non-blow out zinc oxide varistor arrester <strong>for</strong> use in distributor housings<br />

• Labelled connections<br />

Application: equipotential bonding in buildings, even those with external lightning protection of<br />

class III and IV, and in standard distributor housings.<br />

Type<br />

Highest Version<br />

Pack. Weight Item No.<br />

Price<br />

continuous<br />

voltage<br />

/pc.<br />

V<br />

pcs kg/% pc<br />

V20-C 3+NPE-280 280 3 + NPE 1 41.700 5094 65 6<br />

V 20-C/...: Surge protection device Type 2 (Class C) to VDE 0675 part 6-11 (DIN EN 61643-11).<br />

• With new MultiBase base part and Multi-connection clamps<br />

• Complete unit consisting of upper part and base, pre-mounted and ready <strong>for</strong> connection<br />

• VDE-tested<br />

• Suitable <strong>for</strong> TN- and TT network <strong>system</strong>s<br />

• Plug-in upper part; upper part can be separated from base without tools<br />

• Including thermal and dynamic separating device<br />

• With visual display of defects<br />

• High current conductivity and long service life<br />

• Marked connections<br />

Application example: residential buildings, single-family homes without outer lightning protection<br />

<strong>system</strong>.<br />

CombiArrester complete block <strong>for</strong> <strong>photovoltaic</strong> Photovoltaic<br />

Type<br />

U max<br />

DC<br />

Version<br />

Item No.<br />

V<br />

pcs kg/% pc<br />

V50-B+C 3-PH600 600 3-pin <strong>for</strong> <strong>photovoltaic</strong> 1 41.000 5093 62 3<br />

V50-B+C 2-PH600 600 2-pin <strong>for</strong> <strong>photovoltaic</strong> 1 30.000 5093 62 8<br />

V 50-B+C/...PH...: Combination arrester Type 1+2 according to EN 61643-11 <strong>for</strong> <strong>photovoltaic</strong><br />

<strong>system</strong>s..<br />

• Complete unit consisting of top and bottom part, pre-mounted and ready <strong>for</strong> connection<br />

• Plug-in upper part, upper part can be separated from bottom without tool<br />

• Incl. thermal and dynamic isolating device<br />

• Y-protection circuit<br />

• low voltage DC protection level: 2.6 kV (Uoc max = 600 V DC with V50-B+C/0-280)<br />

• With visual fault display<br />

• Indicated connections<br />

Pack.<br />

Weight<br />

Example of usage: In <strong>photovoltaic</strong> <strong>system</strong>s between PH modules and inverter<br />

Type<br />

U max<br />

DC<br />

Version<br />

Pack. Weight Item No.<br />

V<br />

pcs kg/% pc<br />

V25-B+C 3-PH505 505 3-pin <strong>for</strong> <strong>photovoltaic</strong>; Δ-connection 1 44.000 5097 44 2<br />

V25-B+C 3-PH900 900 3-pin <strong>for</strong> <strong>photovoltaic</strong>; Y connection 1 42.200 5097 44 7<br />

V25-B+C 2-PH900 900 2-pin <strong>for</strong> <strong>photovoltaic</strong> 1 30.800 5097 45 7<br />

V 25-B+C/...PH...: Combination arrester Type 1+2 according to EN 61643-11 <strong>for</strong> <strong>photovoltaic</strong><br />

<strong>system</strong>s..<br />

• Complete unit consisting of top and bottom part, pre-mounted and ready <strong>for</strong> connection<br />

• Plug-in upper part, upper part can be separated from bottom without tool<br />

• Incl. thermal and dynamic isolating device<br />

• low voltage DC protection level: 3.0 kV (Uoc max = 900 V DC with V25-C/0-385)<br />

• With visual fault display<br />

• Indicated connections<br />

Example of usage: In <strong>photovoltaic</strong> <strong>system</strong>s between PH modules and inverter<br />

Price<br />

/pc.<br />

Price<br />

/pc.<br />

Price<br />

/pc.<br />

02 TBS-Prospekt Photovoltaik / en / 16/11/2009 (LLExport_00789)


02 TBS-Prospekt Photovoltaik / en / 16/11/2009 (LLExport_00789)<br />

Photovoltaic<br />

Photovoltaic<br />

45<br />

45<br />

45<br />

Photovoltaic<br />

48 17.5<br />

48 17.5<br />

48<br />

17.5<br />

V 20-C/...PH...: Surge arrester Type 2 according to EN 61643-11 <strong>for</strong> <strong>photovoltaic</strong> plants.<br />

• Complete unit consisting of top and bottom part, pre-mounted and ready <strong>for</strong> connection<br />

• Plug-in upper part, upper part can be separated from bottom without tool<br />

• Incl. thermal and dynamic isolating device<br />

• With visual fault display<br />

• low voltage DC protection level: 4.0 kV (Uoc max = 1,000 V DC mit V20-C/0-440, Y-connector)<br />

• With visual fault display<br />

• Indicated connections<br />

Example of usage: In <strong>photovoltaic</strong> <strong>system</strong>s between PH modules and inverter<br />

Surge protection<br />

Energy technology<br />

Surge arrester complete block <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s<br />

Type U max<br />

Version<br />

Pack. Weight Item No. Price<br />

DC<br />

/pc.<br />

V<br />

pcs kg/% pc<br />

V20-C 2-PH-1000 1000 2-pin <strong>for</strong> <strong>photovoltaic</strong>; Y connection 1 26.600 5094 61 7<br />

V20-C 3-PH-505 505 3-pin <strong>for</strong> <strong>photovoltaic</strong>; Δ-connection 1 37.100 5094 60 2<br />

V20-C 3-PH-585 585 3-pin <strong>for</strong> <strong>photovoltaic</strong>; Δ-connection 1 37.700 5094 60 4<br />

V20-C 3-PH-745 745 3-pin <strong>for</strong> <strong>photovoltaic</strong>; Δ-connection 1 39.800 5094 60 6<br />

V20-C 3-PH-1000 1000 3-pin <strong>for</strong> <strong>photovoltaic</strong>; Y connection 1 35.900 5094 60 8<br />

CombiController/upper part<br />

Type<br />

Highest U max Version<br />

Pack. Weight Item No. Price<br />

continuous<br />

voltage<br />

DC<br />

/pc.<br />

V V<br />

pcs kg/% pc<br />

V50-B+C 0-280 280 350 1-pole 1 8.000 5093 72 4<br />

Cover<br />

V 50-B+C/0...: CombiController, upper part – Type 1+2 CombiArrester<br />

• Plug-in upper part; upper part can be separated from base without tools and current cut-off in<br />

bottom part<br />

• Including thermal and dynamic separating device and visual fault display<br />

• High current conductivity and long service life<br />

Type<br />

Highest U max Version<br />

Pack. Weight Item No. Price<br />

continuous<br />

voltage<br />

DC<br />

/pc.<br />

V V<br />

pcs kg/% pc<br />

V25-B+C 0-150 150 200 1-pole 1 9.500 5097 08 8<br />

V25-B+C 0-280 280 350 1-pole 1 9.500 5097 05 3<br />

V25-B+C 0-385 385 505 1-pole 1 9.500 5097 06 1<br />

V 25-B+C/0...: CombiController, upper part – Type 1+2 CombiArrester<br />

• Plug-in upper part; upper part can be separated from base without tools and current cut-off in<br />

bottom part<br />

• Including thermal and dynamic separating device and visual fault display<br />

• High current conductivity and long service life<br />

Type<br />

Highest U max Version<br />

Pack. Weight Item No. Price<br />

continuous<br />

voltage<br />

DC<br />

/pc.<br />

V V<br />

pcs kg/% pc<br />

V20-C 0-75<br />

75 100 1-pole 1 5.160 5099 57 9<br />

V20-C 0-150 150 200 1-pole 1 4.794 5096 70 7<br />

V20-C 0-280 280 350 1-pole 1 8.500 5099 60 9<br />

V20-C 0-320-SP 320 420 1-pole 1 5.545 5099 84 8<br />

V20-C 0-335 335 420 1-pole 1 5.545 5099 85 0<br />

V20-C 0-385 385 505 1-pole 1 5.826 5099 59 5<br />

V20-C 0-440 440 585 1-pole 1 6.452 5099 70 6<br />

V20-C 0-550 550 745 1-pole 1 6.452 5099 61 7<br />

upper part<br />

V 20-C/...: SurgeController, upper part – Type 2 surge arrester<br />

• VDE-tested<br />

• Plug-in upper part; upper part can be separated from base without tools<br />

• Including thermal and dynamic separating device and visual fault display<br />

• High current conductivity and long service life<br />

SurgeController/upper part<br />

TBS<br />

17


Surge protection<br />

Energy technology<br />

Lightning current and surge arrester / bases <strong>for</strong> <strong>photovoltaic</strong> plants Photovoltaic<br />

18 TBS<br />

Type<br />

Version<br />

pcs kg/% pc<br />

V20-C U-3PH 3-pin <strong>for</strong> <strong>photovoltaic</strong> 1 27.000 5096 62 6<br />

V20-C U-3PH-FS 3-pin <strong>for</strong> <strong>photovoltaic</strong> with FS 1 27.000 5096 63 4<br />

V 20-C/U...: Bottom part <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s (Δ-circuit)<br />

Item No.<br />

• Suitable <strong>for</strong> V 50-B+C and V25-B+C upper parts types 1+2 combination arrester<br />

• Suitable <strong>for</strong> V 20-C upper parts type 2 surge arrester<br />

• Protection circuit against transverse and longitudinal voltages<br />

• Δ-circuit<br />

• Low protection level < 2.4 kV (Uoc max = 745 V DC with V20-C/0-550)<br />

• Low protection level < 1.5 kV (Uoc max = 505 V DC with V25-B+C/0-385)<br />

• Low protection level < 1.3 kV (Uoc max = 350 V DC with V50-C/0-280)<br />

Pack.<br />

Weight<br />

Indicated connectors<br />

Application: In <strong>photovoltaic</strong> <strong>system</strong>s between PH modules and inverters.<br />

Type<br />

Version<br />

Item No.<br />

pcs kg/% pc<br />

V20-C U-3PH-Y 3-pin Y connection 1 17.000 5096 64 7<br />

V 20-C/3-PH-Y: Bottom part <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s up to Uoc = 1,000 V (Y-circuit)<br />

Pack.<br />

Weight<br />

• Suitable <strong>for</strong> V 25-B+C upper parts type 1+2 combination arrester<br />

• Suitable <strong>for</strong> V 20-C upper parts type 2 surge arrester<br />

• Protection circuit against transverse and longitudinal voltages<br />

• Y-protection circuit<br />

• Low protection level < 4.0 kV (Uoc max = 1,000 V DC with V20-C/0-440)<br />

• Low protection level < 3.0 kV (Uoc max = 900 V DC with V25-B+C/0-385)<br />

• Low protection level < 2.6 kV (Uoc max = 600 V DC with V50-C/0-280)<br />

Indicated connectors<br />

Application: In <strong>photovoltaic</strong> <strong>system</strong>s between PH modules and inverters.<br />

Type<br />

Version<br />

pcs kg/% pc<br />

V20-C U-2 PH 2-pin 1 14.000 5096 63 7<br />

V20-C U-2 PH+FS 2-pin with FS 1 18.000 5096 63 9<br />

V 20-C/U-2PH: Bottom part <strong>for</strong> earthed <strong>photovoltaic</strong> <strong>system</strong>s up to Uoc = 1,000 V<br />

• Suitable <strong>for</strong> V 50-B+C and B+C upper parts types 1+2 combination arrester<br />

• Suitable <strong>for</strong> V 20-C upper parts type 2 surge arrester<br />

• Protection circuit against transverse and longitudinal voltages<br />

• Protective circuit <strong>for</strong> earthed PV <strong>system</strong>s between + and –/Earth<br />

• Low protection level < 4.0 kV (Uoc max = 1,000 V DC with V20-C/0-440)<br />

• Low protection level < 3.0 kV (Uoc max = 900 V DC with V25-B+C/0-385)<br />

• Low protection level < 2.6 kV (Uoc max = 600 V DC with V50-B+C/0-280)<br />

Indicated connectors<br />

Application: In <strong>photovoltaic</strong> <strong>system</strong>s between PH modules and inverters.<br />

Photovoltaic <strong>system</strong> solution Photovoltaic<br />

Type<br />

Version<br />

Pack.<br />

Weight<br />

Item No.<br />

pcs kg/% pc<br />

VG-C DC-PH550 DC protection complete, incl. housing 1 150.000 5088 69 0<br />

System solution <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s (Δ-connection)<br />

• Version -550 is equipped with V20-C/0-550 arrester<br />

• High current arresting capacity and long service life<br />

• Plug-in arrester ready <strong>for</strong> connection with dynamic cut-off unit and visual fault display<br />

• Low DC protection level: < 2.4 kV (Uoc max = 745 V DC with V20-C/0-550)<br />

• DC side with MC connector (series: PV-AD...P 4/6)<br />

• Central earthing point<br />

• pre-assembled and ready <strong>for</strong> connection<br />

• Housing IP65 with transparent and sealable door<br />

Application: surge protection of the current inverter<br />

Pack.<br />

Weight<br />

Item No.<br />

Price<br />

/pc.<br />

Price<br />

/pc.<br />

Price<br />

/pc.<br />

Price<br />

/pc.<br />

50<br />

70<br />

90<br />

02 TBS-Prospekt Photovoltaik / en / 16/11/2009 (LLExport_00789)


02 TBS-Prospekt Photovoltaik / en / 16/11/2009 (LLExport_00789)<br />

Photovoltaic<br />

Type<br />

VG-C DC-PHU<br />

System solution <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s (Δ-connection)<br />

• Version -U is unequipped, <strong>for</strong> V50, V25 or V20 arrester<br />

• Plug-in arrester ready <strong>for</strong> connection with dynamic cut-off unit and visual fault display<br />

• Low DC protection level: < 2.4 kV (Uoc max = 745 V DC with V20-C/0-550)<br />

• Low DC protection level: < 1.5 kV (Uoc max = 505 V DC with V25-B+C/0-385)<br />

• Low DC protection level: < 1.3 kV (Uoc max = 350 V DC with V50-B+C/0-280)<br />

• DC side with MC connector (series: PV-AD...P 4/6)<br />

• Central earthing point<br />

• pre-assembled and ready <strong>for</strong> connection<br />

• Housing IP65 with transparent and sealable door<br />

Application: surge protection of the current inverter<br />

Surge protection<br />

Energy technology<br />

Photovoltaic <strong>system</strong> solution<br />

Version<br />

Pack. Weight Item No. Price<br />

/pc.<br />

pcs kg/% pc<br />

DC protection unequipped, incl. housing 1 150.000 5088 69 7<br />

Type<br />

Version<br />

Pack. Weight Item No. Price<br />

/pc.<br />

pcs kg/% pc<br />

VG-C DC-PH-Y DC protection unequipped, incl. housing 1 150.000 5088 69 9<br />

System solution <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s (Y-connection)<br />

• Version -VG-C/DC-PH-Y is unequipped, <strong>for</strong> V50, V25 or V20 arrester<br />

• Plug-in arrester ready <strong>for</strong> connection with dynamic cut-off unit and visual fault display<br />

• Low DC protection level: < 4.0 kV (Uoc max = 1,000 V DC with V20-C/0-440)<br />

• Low DC protection level: < 3.0 kV (Uoc max = 900 V DC with V25-B+C/0-385)<br />

• Low DC protection level: < 2.6 kV (Uoc max = 600 V DC with V50-B+C/0-280)<br />

• Y-protection circuit<br />

• DC side with MC connector (series: PV-AD...P 4/6)<br />

• Central earthing point<br />

• pre-assembled and ready <strong>for</strong> connection<br />

• Housing IP65 with transparent and sealable door<br />

Application: surge protection of the current inverter<br />

Type<br />

U max<br />

DC<br />

Version<br />

Pack. Weight Item No.<br />

V<br />

pcs kg/% pc<br />

VG-C ACDC-PH550 745 AC+DC protection, incl. housing 1 200.000 5088 68 6<br />

System solution <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s (DC Δ-connection)<br />

• Version -550 is equipped with V20-C/0-550 arrester (DC side)<br />

• Plug-in arrester ready <strong>for</strong> connection with dynamic cut-off unit and visual fault display<br />

• Low DC protection level: < 2.4 kV (Uoc = 745 VDC with V20-C/0-550)<br />

• DC side with MC connector (series: PV-AD...P 4/6)<br />

• AC side with 1+NPE protection circuit<br />

• Central earthing point<br />

• pre-assembled and ready <strong>for</strong> connection<br />

• Housing IP65 with transparent and sealable door<br />

Application: surge protection of the current inverter<br />

Type<br />

U max<br />

DC<br />

Version<br />

Pack. Weight Item No.<br />

V<br />

pcs kg/% pc<br />

VG-C DC-PH-MS — Multistring DC protection unequipped 1 135.000 5088 69 4<br />

VG-C DCPH-MS1000 1000 Multistring type 2 – DC protection 1 154.000 5088 69 1<br />

VG-BC DCPH-MS900 900 Multistring types 1+2 – DC protection 1 160.000 5088 69 2<br />

VG-BC DCPH-MS600 600 Multistring types 1+2 – DC protection<br />

System solution <strong>for</strong> <strong>photovoltaic</strong> <strong>system</strong>s (Y-connection)<br />

1 159.000 5088 69 3<br />

• Housing IP65 complete with surge arrester<br />

• -MS version is unequipped; <strong>for</strong> V25 or V20 arrester<br />

• Pre-mounted and ready <strong>for</strong> connection<br />

• High current arresting capacity and long service life<br />

• Plug-in arrester with dynamic cut-off device and visual fault display<br />

• Low DC protection level: < 4.0 kV (Uoc = 1000 VDC with V20-C/0-440)<br />

• Low DC protection level: < 1.5 kV (Uoc = 900 VDC with V25-B+C/0-385)<br />

• Y protection circuit<br />

• Multistring: six connection terminals <strong>for</strong> each polarity<br />

Application: overvoltage protection of the current inverter<br />

Price<br />

/pc.<br />

Price<br />

/pc.<br />

TBS<br />

19


VBS connection and<br />

fastening <strong>system</strong>s<br />

Junction box <strong>system</strong>s<br />

Concealed and cavity wall <strong>system</strong>s<br />

Terminal <strong>system</strong>s<br />

Cable gland <strong>system</strong>s<br />

Cable and pipe fastening <strong>system</strong>s, plastic<br />

Cable and pipe fastening <strong>system</strong>s, metal<br />

Cable and pipe fastening <strong>system</strong>s, special<br />

Pipe <strong>system</strong>s<br />

Support clamp <strong>system</strong>s<br />

Rail <strong>system</strong>s<br />

BBS clamp clip <strong>system</strong>s<br />

Bolt and hammerset <strong>system</strong>s<br />

TBS transient and<br />

lightning protection <strong>system</strong>s<br />

Surge protection <strong>system</strong>s<br />

Equipotential bonding <strong>system</strong>s<br />

Lightning protection <strong>system</strong>s<br />

Earthing <strong>system</strong>s<br />

<strong>OBO</strong> BETTERMANN GmbH & Co. KG<br />

P.O. Box 1120 · 58694 Menden · Germany<br />

Phone +49 (0) 23 73 89-0 · Fax +49 (0) 23 73 89-2 38<br />

E-mail: info@obo.de · www.obo-bettermann.com<br />

Conducting electricity.<br />

Routing data.<br />

Controlling energy.<br />

KTS cable support <strong>system</strong>s<br />

Mounting <strong>system</strong>s<br />

Cable tray <strong>system</strong>s<br />

Mesh cable tray <strong>system</strong>s<br />

Cable ladder <strong>system</strong>s<br />

Wide span <strong>system</strong>s<br />

Vertical ladder <strong>system</strong>s<br />

Luminaire support <strong>system</strong>s<br />

Modular <strong>system</strong>s<br />

Stainless steel <strong>system</strong>s<br />

Function maintenance <strong>system</strong>s<br />

and escape route installation <strong>system</strong>s<br />

BSS fire protection <strong>system</strong>s<br />

Insulation <strong>system</strong>s<br />

Escape route installation <strong>system</strong>s<br />

Fire protection duct <strong>system</strong>s<br />

Function maintenance <strong>system</strong>s<br />

LFS cable trunking <strong>system</strong>s<br />

Plastic line routing trunking <strong>system</strong>s<br />

Metal line routing trunking <strong>system</strong>s<br />

Skirting trunking <strong>system</strong>s<br />

Wiring trunking <strong>system</strong>s<br />

Plastic device installation trunking <strong>system</strong>s<br />

Sheet steel device installation trunking <strong>system</strong>s<br />

Aluminium device installation trunking <strong>system</strong>s<br />

Service pole <strong>system</strong>s<br />

Device <strong>system</strong>s<br />

Fire protection trunking <strong>system</strong>s<br />

EGS device <strong>system</strong>s<br />

Sockets-45 <strong>system</strong>s<br />

Device-45 <strong>system</strong>s<br />

Data technology-45 <strong>system</strong>s<br />

Fitted and accessories-45 <strong>system</strong>s<br />

Intelligent workplace <strong>system</strong>s<br />

Industry and special connection<br />

<strong>system</strong>s<br />

Energy distribution <strong>system</strong>s<br />

Socket and device <strong>system</strong>s,<br />

Data technology-80 <strong>system</strong>s<br />

<strong>OBO</strong> BUS <strong>system</strong>s<br />

UFS underfloor <strong>system</strong>s<br />

Underfloor <strong>system</strong>s, screed-covered<br />

Underfloor <strong>system</strong>s, flushfloor open<br />

Underfloor <strong>system</strong>s, flushfloor closed<br />

Underfloor <strong>system</strong>s, in-concrete<br />

Onfloor <strong>system</strong>s<br />

Device installation <strong>system</strong>s<br />

Module 45 <strong>system</strong>s and data technology<br />

Fire protection <strong>system</strong>s<br />

© <strong>OBO</strong> BETTERMANN © <strong>OBO</strong> BETTERMANN Order-No. 9196111 Order 03/2007 no. D9196114<br />

08/2009 EN

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!