TWH Series Fan Forced Wall Insert Heater
TWH Series Fan Forced Wall Insert Heater
TWH Series Fan Forced Wall Insert Heater
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
CH <strong>Series</strong><br />
Chromalox Product Order Logic<br />
Order logic example<br />
Catalogue Number Options<br />
CH3D 04 A 3 W<br />
<strong>Series</strong> Watts Voltage<br />
Selection<br />
Control<br />
Options<br />
Colour<br />
Options<br />
Ordering Guide<br />
Length Weight<br />
Cat. No. Watts BTU Available Voltages CFM mm/in. kg/lbs.<br />
CH3D02 2000 6840 A,B,D,F,G,H,I,J 250/200 812.8/32 50.0/110<br />
CH3D03 3000 10260 A,B,D,F,G,H,I,J 250/200 812.8/32 50.0/110<br />
CH3D04 4000 13700 A,B,D,F,G,H,I,J 250/200 812.8/32 50.0/110<br />
CH3D05 5000 17100 A,B,D,F,G,H,I,J 250/200 812.8/32 50.0/110<br />
CH3D06 6000 20500 A,B,D,F,G,H,I,J 250/200 812.8/32 50.0/110<br />
CH4D04 4000 13700 A,B,D,F,G,H,I,J 500/400 1143/45 67.4/145<br />
CH4D06 6000 20500 A,B,D,F,G,H,I,J 500/400 1143/45 67.4/145<br />
CH4D08 8000 27300 A,B,D,F,G,H,I,J 500/400 1143/45 67.4/145<br />
CH4D10 10000 34120 A,B,D,F,G,H,I,J 500/400 1143/45 67.4/145<br />
CH4D12 12000 41000 D,G,H,J 500/400 1143/45 67.4/145<br />
CH6D15 15000 51180 D,F,J 750/600 1651/65 112.0/240<br />
CH6D18 18000 61416 D,F,J 750/600 1651/65 112.0/240<br />
1. Specify desired voltage and control option<br />
at time of ordering – example: CH4D04A3<br />
2. Standard colour is almond – to order white,<br />
add “W” in Cat. No.<br />
3. Consult factory for custom finish<br />
requirements<br />
Voltage Selection<br />
Code Voltage Phase<br />
A 208 1<br />
B 240 1<br />
D 208 3<br />
F 480 3<br />
G 480 1<br />
H 347 1<br />
I 600 1<br />
J 600 3<br />
Control Options (factory installed)<br />
Code<br />
Description<br />
3 Built-in single pole thermostat control<br />
High/low control switch for heat/fan, on/off control switch<br />
T Built-in low voltage relay kit for remote 24V thermostat (not included)<br />
High/low control switch for heat/fan<br />
R Provision for remote wired control (not included) high/low control<br />
switch for heat/fan. Control circuits are 240V on all units except 208V<br />
which has control voltage the same as supply voltage<br />
C Duct transition collar for connection to ducting<br />
S Disconnect switch for positive power interruption<br />
X High speed motor for ceiling mount applications<br />
Dimensions<br />
235mm<br />
[9 1/4"]<br />
54mm[2 1/8"]<br />
"L" “L”<br />
813, 1143, 1143, 1650mm 1651, 1981mm<br />
(32", [45", 45", 65"] 65", 78")<br />
"X"<br />
225mm[8 7/8"]<br />
NOTE CEILING MOUNTING HOLES ARE SHOWN<br />
AS VIEWED FROM FRONT OF HEATER<br />
UNIT “X”<br />
32" 15" (381mm)<br />
45" 29" (737mm)<br />
65" 49" (1245mm)<br />
241mm<br />
[9 1/2"]<br />
OUTLET<br />
CONTROL SECTION<br />
14mm[9/16"] DIA. KNOCKOUTS<br />
FOR CEILING MOUNT<br />
(SEE NOTE)<br />
"A"<br />
INLET "C"<br />
FRONT PANEL<br />
FRONT VIEW<br />
NOTE<br />
CEILING MOUNTING HOLES ARE<br />
SHOWNASVIEWEDFROMFRONT<br />
"B"<br />
76mm[3"]<br />
635mm[25"]<br />
"E"<br />
"D"<br />
70mm[2 3/4"]<br />
133mm[5 1/8"]<br />
184mm[7 1/4"]<br />
R.H. VIEW<br />
64mm[2 1/2"]<br />
76mm[3"]<br />
KNOCKOUT SCHEDULE<br />
ITEM SIZE (MILLIMETERS/INCHES) QTY.<br />
"A" 35/51mm[1 3/8"/2"]DIA. 2<br />
UNIT "B" 45mm[1 X 3/4"] 2<br />
43mm[45"] = "C" 737mm[29"] 22mm[7/8"]<br />
50mm[65"] = "D" 1245mm[49"] 45/51mm[1 3/4"/2"]<br />
2<br />
1<br />
"E" 35mm[1 3/8"] 1<br />
BOTTOM VIEW<br />
"C"<br />
"A"<br />
"B"<br />
38mm[1 1/2"]<br />
TO ORDER PLEASE CALL 1-800-668-6663 OR FAX 1-800-668-6665 COMMERCIAL HEATERS | 29