CH <strong>Series</strong><br />

Chromalox Product Order Logic<br />

Order logic example<br />

Catalogue Number Options<br />

CH3D 04 A 3 W<br />

<strong>Series</strong> Watts Voltage<br />

Selection<br />

Control<br />

Options<br />

Colour<br />

Options<br />

Ordering Guide<br />

Length Weight<br />

Cat. No. Watts BTU Available Voltages CFM mm/in. kg/lbs.<br />

CH3D02 2000 6840 A,B,D,F,G,H,I,J 250/200 812.8/32 50.0/110<br />

CH3D03 3000 10260 A,B,D,F,G,H,I,J 250/200 812.8/32 50.0/110<br />

CH3D04 4000 13700 A,B,D,F,G,H,I,J 250/200 812.8/32 50.0/110<br />

CH3D05 5000 17100 A,B,D,F,G,H,I,J 250/200 812.8/32 50.0/110<br />

CH3D06 6000 20500 A,B,D,F,G,H,I,J 250/200 812.8/32 50.0/110<br />

CH4D04 4000 13700 A,B,D,F,G,H,I,J 500/400 1143/45 67.4/145<br />

CH4D06 6000 20500 A,B,D,F,G,H,I,J 500/400 1143/45 67.4/145<br />

CH4D08 8000 27300 A,B,D,F,G,H,I,J 500/400 1143/45 67.4/145<br />

CH4D10 10000 34120 A,B,D,F,G,H,I,J 500/400 1143/45 67.4/145<br />

CH4D12 12000 41000 D,G,H,J 500/400 1143/45 67.4/145<br />

CH6D15 15000 51180 D,F,J 750/600 1651/65 112.0/240<br />

CH6D18 18000 61416 D,F,J 750/600 1651/65 112.0/240<br />

1. Specify desired voltage and control option<br />

at time of ordering – example: CH4D04A3<br />

2. Standard colour is almond – to order white,<br />

add “W” in Cat. No.<br />

3. Consult factory for custom finish<br />

requirements<br />

Voltage Selection<br />

Code Voltage Phase<br />

A 208 1<br />

B 240 1<br />

D 208 3<br />

F 480 3<br />

G 480 1<br />

H 347 1<br />

I 600 1<br />

J 600 3<br />

Control Options (factory installed)<br />

Code<br />

Description<br />

3 Built-in single pole thermostat control<br />

High/low control switch for heat/fan, on/off control switch<br />

T Built-in low voltage relay kit for remote 24V thermostat (not included)<br />

High/low control switch for heat/fan<br />

R Provision for remote wired control (not included) high/low control<br />

switch for heat/fan. Control circuits are 240V on all units except 208V<br />

which has control voltage the same as supply voltage<br />

C Duct transition collar for connection to ducting<br />

S Disconnect switch for positive power interruption<br />

X High speed motor for ceiling mount applications<br />

Dimensions<br />

235mm<br />

[9 1/4"]<br />

54mm[2 1/8"]<br />

"L" “L”<br />

813, 1143, 1143, 1650mm 1651, 1981mm<br />

(32", [45", 45", 65"] 65", 78")<br />

"X"<br />

225mm[8 7/8"]<br />

NOTE CEILING MOUNTING HOLES ARE SHOWN<br />

AS VIEWED FROM FRONT OF HEATER<br />

UNIT “X”<br />

32" 15" (381mm)<br />

45" 29" (737mm)<br />

65" 49" (1245mm)<br />

241mm<br />

[9 1/2"]<br />

OUTLET<br />

CONTROL SECTION<br />

14mm[9/16"] DIA. KNOCKOUTS<br />

FOR CEILING MOUNT<br />

(SEE NOTE)<br />

"A"<br />

INLET "C"<br />

FRONT PANEL<br />

FRONT VIEW<br />

NOTE<br />

CEILING MOUNTING HOLES ARE<br />

SHOWNASVIEWEDFROMFRONT<br />

"B"<br />

76mm[3"]<br />

635mm[25"]<br />

"E"<br />

"D"<br />

70mm[2 3/4"]<br />

133mm[5 1/8"]<br />

184mm[7 1/4"]<br />

R.H. VIEW<br />

64mm[2 1/2"]<br />

76mm[3"]<br />

KNOCKOUT SCHEDULE<br />

ITEM SIZE (MILLIMETERS/INCHES) QTY.<br />

"A" 35/51mm[1 3/8"/2"]DIA. 2<br />

UNIT "B" 45mm[1 X 3/4"] 2<br />

43mm[45"] = "C" 737mm[29"] 22mm[7/8"]<br />

50mm[65"] = "D" 1245mm[49"] 45/51mm[1 3/4"/2"]<br />

2<br />

1<br />

"E" 35mm[1 3/8"] 1<br />

BOTTOM VIEW<br />

"C"<br />

"A"<br />

"B"<br />

38mm[1 1/2"]<br />

TO ORDER PLEASE CALL 1-800-668-6663 OR FAX 1-800-668-6665 COMMERCIAL HEATERS | 29