Mo<strong>de</strong>l and Suffix Co<strong>de</strong><br />
Specifications<br />
Mo<strong>de</strong>l and Suffix Co<strong>de</strong><br />
<strong>REX</strong>-<strong>P48</strong><br />
Mo<strong>de</strong>l<br />
<strong>REX</strong>-<strong>P96</strong><br />
PID reverse control with AT<br />
F<br />
PID direct control with AT<br />
D<br />
Control method<br />
Level PID reverse control with AT<br />
L<br />
Level PID direct control with AT<br />
M<br />
Heat/cool PID control<br />
W<br />
Heat/cool level PID control<br />
V<br />
Input type<br />
See input range co<strong>de</strong> table<br />
Scale range<br />
See input range co<strong>de</strong> table<br />
Relay output<br />
Control output (OUT1)<br />
Voltage pulse<br />
DC current : 0 to 20mA<br />
DC current : 4 to 20mA<br />
Control action : F, D, L, M<br />
Relay output<br />
Control output (OUT2) Voltage pulse<br />
DC current : 0 to 20mA<br />
DC current : 4 to 20mA<br />
No alarm<br />
Alarm 1<br />
See alarm co<strong>de</strong> table<br />
No alarm<br />
Alarm 2<br />
See alarm co<strong>de</strong> table<br />
Not supplied<br />
Contact input<br />
Supplied<br />
Not supplied<br />
Output function<br />
Pattern end output<br />
Time signal output<br />
Not supplied<br />
Analog output<br />
See analog output co<strong>de</strong> table<br />
For <strong>REX</strong>-<strong>P48</strong>/96 with CE mark, UL and CSA approval, please add the suffix of "/CE" at the end of the mo<strong>de</strong>l co<strong>de</strong>.<br />
M<br />
V<br />
7<br />
8<br />
No symbol<br />
M<br />
V<br />
7<br />
8<br />
N<br />
N<br />
N<br />
Y<br />
N<br />
1<br />
2<br />
N<br />
Input range co<strong>de</strong><br />
Thermocouple<br />
Input Co<strong>de</strong> Range<br />
K 22 -199.9 999.9°C<br />
K 16 -200 1372°C<br />
K K B2 -199.9 999.9°F<br />
K B3 -330 2500°F<br />
J 14 -199.9 999.9°C<br />
J 15 -200 1200°C<br />
J<br />
J A9 -199.9 999.9°F<br />
J B1 -330 2192°F<br />
T 01 -199.9 400.0°C<br />
T<br />
T A1 -199.9 752.0°F<br />
Input Co<strong>de</strong> Range<br />
R 02 0 1769°C<br />
R R A2 0 3216°F<br />
S 02 0 1769°C<br />
S S A2 0 3216°F<br />
B 02 0 1820°C<br />
B B A2 0 3308°F<br />
E 06 -200 1000°C<br />
E E A5 -330 1832°F<br />
N<br />
N 02 0 1200°C<br />
N A2 0 2372°F<br />
Input Co<strong>de</strong> Range<br />
A 02 0 1390°C<br />
PLII A A2 0 2534°F<br />
W5Re W 02 0 2320°C<br />
/W26Re W A4 0 4208°F<br />
U<br />
L<br />
U 08 0 600°C<br />
U A4 0 1100°F<br />
L 05 0 900°C<br />
L A2 0 1600°F<br />
RTD<br />
Input Co<strong>de</strong> Range<br />
P 20<br />
JPt100<br />
-199.9 510.0°C<br />
P B6 -199.9 950.0°F<br />
D 20 -199.9 660.0°C<br />
Pt100 D A1 -199.9 999.9°F<br />
Alarm co<strong>de</strong><br />
Analog output co<strong>de</strong><br />
Co<strong>de</strong> Type<br />
A Deviation High<br />
B Deviation Low<br />
C Deviation High/Low<br />
D Band Alarm<br />
E Deviation High with Alarm Hold<br />
F Deviation Low with Alarm Hold<br />
G Deviation High/Low with Alarm Hold<br />
H Process High<br />
Co<strong>de</strong> Type<br />
J Process Low<br />
K Process High with Alarm Hold<br />
L Process Low with Alarm Hold<br />
Q Deviation High with Alarm Re-hold<br />
S Deviation Low with Alarm Re-hold<br />
T Deviation High/Low with Alarm Re-hold<br />
V Set value High<br />
W Set value Low<br />
Co<strong>de</strong> Type<br />
1 0 10mV DC<br />
2 0 100mV DC<br />
3 0 1V DC<br />
4 0 5V DC<br />
5 0 10V DC<br />
6 1 5V DC<br />
7 0 20mA DC<br />
8 4 20mA DC<br />
* On alarm re-hold function: The alarm will become effective after it<br />
has first entered non-alarm range, when alarm set values are<br />
changed.<br />