- Page 1 and 2: Energie-Messtechnik 27(3 6$/,59 21,
- Page 3 and 4: Chapter 01 Company profile 3 3P-str
- Page 5 and 6: The customers Janitza electronics
- Page 7 and 8: An overview of application options
- Page 9 and 10: PQM - Power Quality Monitoring PQM
- Page 11 and 12: Type Item number 52.13.001 52.13.00
- Page 13 and 14: PQM - Power Quality Monitoring Univ
- Page 15 and 16: UMG 103 Communication options: Onli
- Page 17 and 18: t UMG 103 Typical connection option
- Page 19 and 20: UMG 104 PQM - Power Quality Monitor
- Page 21 and 22: t t UMG 104 overview Central Buildi
- Page 23 and 24: t UMG 104 Technical data Nominal vo
- Page 25 and 26: UMG 604 PQM - Power Quality Monitor
- Page 27 and 28: UMG 604 DIN rail mounting (6 units)
- Page 29 and 30: UMG 604 Online monitoring with the
- Page 31 and 32: t UMG 604 Router PLC Software Netwo
- Page 33 and 34: t UMG 604 Measurement values Voltag
- Page 35 and 36: UMG 605 PQM - Power Quality Monitor
- Page 37 and 38: UMG 605 Router PLC Software Network
- Page 39 and 40: t UMG 605 Measurement values Voltag
- Page 41 and 42: PQM - Power Quality Monitoring Univ
- Page 43 and 44: UMG 96L / UMG 96 Measurement value
- Page 45: t UMG 96L / UMG 96 Typical connecti
- Page 49 and 50: UMG 96S Data storage / memory Up to
- Page 51 and 52: t UMG 96S Networks TN and TT netwo
- Page 53 and 54: t UMG 96S Measurement range Voltage
- Page 55 and 56: UMG 96RM PQM - Power Quality Monito
- Page 57 and 58: UMG 96RM Typical applications In or
- Page 59 and 60: UMG 96RM Router PLC Software Networ
- Page 61 and 62: t UMG 96RM General technical data N
- Page 63 and 64: UMG 503 PQM - Power Quality Monitor
- Page 65 and 66: UMG 503 Data memory A ring buffer f
- Page 67 and 68: t UMG 503 Overview of product varia
- Page 69 and 70: t UMG 503 Periphery Digital inputs
- Page 71 and 72: UMG 505 PQM - Power Quality Monitor
- Page 73 and 74: UMG 505 Measurement value displays
- Page 75 and 76: t UMG 505 Modem PLC Software 4 digi
- Page 77 and 78: t UMG 505 Measurement values Measur
- Page 79 and 80: UMG 507 PQM - Power Quality Monitor
- Page 81 and 82: UMG 507 GridVis software The UMG 50
- Page 83 and 84: t UMG 507 1 temperature input - PT
- Page 85 and 86: t UMG 507 Measurement values Measur
- Page 87 and 88: UMG 508 PQM - Power Quality Monitor
- Page 89 and 90: UMG 508 Router PLC Software Grids
- Page 91 and 92: t UMG 508 Technical data Nominal vo
- Page 93 and 94: UMG 511 PQM - Power Quality Monitor
- Page 95 and 96: UMG 511 Display examples The backli
- Page 97 and 98:
t UMG 511 Dimensional drawing Conne
- Page 99 and 100:
t UMG 511 Measurement values Voltag
- Page 101 and 102:
PM - Power Management PM - Power Ma
- Page 103 and 104:
PM - Power Management Electronic en
- Page 105 and 106:
Product variants and technical data
- Page 107 and 108:
Module technology Communication mod
- Page 109 and 110:
PM - Power Management UMG 508Emax U
- Page 111 and 112:
UMG 508Emax Applications: The UMG 5
- Page 113 and 114:
Supply voltage: 95 .. 240V AC, 135
- Page 115 and 116:
Emax APPs Emax variants as APP The
- Page 117 and 118:
PM - Power Management ProData ® Pr
- Page 119 and 120:
ProData ® Analogue inputs 1 anal
- Page 121 and 122:
t ProData ® Overview of product va
- Page 123 and 124:
PQS - Power Quality Solutions PQS -
- Page 125 and 126:
PQS - Power Quality Solutions Proph
- Page 127 and 128:
Prophi ® power factor controller V
- Page 129 and 130:
Prophi ® power factor controller M
- Page 131 and 132:
PQS - Power Quality Solutions PFC M
- Page 133 and 134:
PQS - Power Quality Solutions Power
- Page 135 and 136:
Can-type capacitor in aluminium hou
- Page 137 and 138:
PQS - Power Quality Solutions Autom
- Page 139 and 140:
Compact design Automatic PFC in com
- Page 141 and 142:
Mounting plate Automatic PFC system
- Page 143 and 144:
PQS - Power Quality Solutions De-tu
- Page 145 and 146:
De-tuned power factor correction (w
- Page 147 and 148:
t Extractable modular design 7% De-
- Page 149 and 150:
t Extractable modular design De-tun
- Page 151 and 152:
Dynamic (fast switching) power fact
- Page 153 and 154:
t Extractable modular design De-tun
- Page 155 and 156:
t Extractable modular design 7% De-
- Page 157 and 158:
t Capacitor modules and accessories
- Page 159 and 160:
Software Software solutions - espec
- Page 161 and 162:
GridVis Software Grid visualisation
- Page 163 and 164:
GridVis Applications The d
- Page 165 and 166:
GridVis Topology View (Graphical Us
- Page 167 and 168:
GridVis Licenses Optional the follo
- Page 169 and 170:
APPs Extensions (APPs) APPs - Expan
- Page 171 and 172:
APPs APP Fault message (item no 51.
- Page 173 and 174:
OPC server Software GLT Intranet Mo
- Page 175 and 176:
OPC server The meaning of OPC OPC i
- Page 177 and 178:
Accessories Accessories The respect
- Page 179 and 180:
Current transformers Accessories Cu
- Page 181 and 182:
Moulded case current transformer cl
- Page 183 and 184:
Summation current transformers (CTs
- Page 185 and 186:
Cable split core CTs Technical data
- Page 187 and 188:
t DIN-rail current transformer DIN-
- Page 189 and 190:
t Current transformer DINCT64/1/1 -
- Page 191 and 192:
Mechanical accessories Accessories
- Page 193 and 194:
Mechanical accessories Accessories
- Page 195 and 196:
IT and field bus components Accesso
- Page 197 and 198:
t Overview I/O fieldbus series FBM1
- Page 199 and 200:
t Field bus components Accessories
- Page 201 and 202:
Field bus components Industrial DIN
- Page 203 and 204:
Field bus components PowerToStore 1
- Page 205 and 206:
NTP server Accessories NTP Time Ser
- Page 207 and 208:
Server Accessories Database server
- Page 209 and 210:
t Server Application: GridVis on th
- Page 211 and 212:
Touch panels Accessories Touch pane
- Page 213 and 214:
t Touch panels A UMG 604 or UMG 605
- Page 215 and 216:
Touch panels Functions and technica
- Page 217 and 218:
Appendix Janitza electronics ® Gmb
- Page 219 and 220:
Cos-phi Calculating the kvar system
- Page 221 and 222:
Communication Overview of the avail
- Page 223 and 224:
Logistics information Cardboard pac
- Page 225 and 226:
Application example PFC using the P
- Page 227 and 228:
Application example UMG 511 Measure