13.07.2015 Views

wound primary current transformers high performance p80sb series

wound primary current transformers high performance p80sb series

wound primary current transformers high performance p80sb series

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LOW VOLTAGE INSTRUMENT TRANSFORMERSWOUND PRIMARY CURRENT TRANSFORMERSHIGH PERFORMANCE P80SB SERIESP80SB• Primary <strong>current</strong> from 0 to 150A• Insulation 0.75/4 kV• Measurement and protection• High <strong>performance</strong> characteristicsMoulded case <strong>current</strong> transformer forthe measurement of AC <strong>current</strong>s up to150 A.This <strong>current</strong> transformer has beendesigned to meet the most demandingrequirements, especially for protectionrelays.Technical dataHighest voltage for equipment 750 VPower-frequency withstand voltage 4000 VPrimary <strong>current</strong> Ipn0 to 150 ASecondary <strong>current</strong> Isn5 or 1 AFrequency50 or 60 HzRated output1 to 60 VAAccuracy class 0.5 - 1 - 3Security factor < 5Continuous thermal <strong>current</strong>1.2 IpnShort-time thermal <strong>current</strong> Ith80 Ipn.1sDynamic <strong>current</strong> Idyn2.5 IthInsulation classEAmbient temperature -25 °C to +40 °CCaseThermoplastic UL94 V0Standards CEI 44-1 - NF C42502 - VDE 0414 - BS 7626Other characteristics on requestHighest voltage for equipment Up to 2400 VPower-frequency withstand voltage Up to 11 kVSecondary <strong>current</strong> Isn0.005 to 10 AFrequency1 to 10000 HzAccuracy class0.1 - 0.2 - 0.2S - 0.5S - 5P - 10P - clXAccuracy limit factor 5 - 10 - 15 - 20 - 30Multi-ratioMultiple coresAmbient temperature -40 °C to +70 °CStandards ANSI C57.13 - CAN3 C13 - AS 1675Accessories / OptionsMounting bracketsStrengthened mounting bracketsSealable terminal coverTropicalizationSAVI packageEA or EN typesEB typeFull set of <strong>primary</strong> nuts and boltsfor 50 <strong>wound</strong> <strong>primary</strong> <strong>transformers</strong>RS ISOLSEC France PAGE 14 NOTICE: M2AB/2


WOUND PRIMARY CURRENT TRANSFORMERS - HIGH PERFORMANCE P80SB SERIESP80SB with EA type brackets44 + AInstallation• Dimension A = 0 as standard and may be increased according to specifications• The useful depth of the M8 thread is 7 mm for all <strong>wound</strong> <strong>primary</strong> <strong>current</strong> <strong>transformers</strong>.It is recommended that a brass stud is used to link the bar or the cable lug with the transformer<strong>primary</strong>.The stud must be screwed in by hand to the full depth of the M8 insert.• Primary tightening torque = 25Nm on bars - 15 Nm on cable lugs137∅ 6,316 60 + AA30InM 569S1S2∅ 17M8 insertP1M 8157,582,5Flat washer ∅ 866 + A155M8 studOnduflex washer ∅ 8HuM8 nutP80SB with EN type brackets6,11571916 6030M56979,5S1 S2∅ 17P1 154,5M 8177P80SB with EB type brackets54 + A16 60 + AA13730∅ 7M 569S1S2∅ 17P1M 816082,566 + A180RS ISOLSEC France PAGE 15 NOTICE: M2AB/2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!