Assembl<strong>in</strong>g and ope<strong>ra</strong><strong>tio</strong>nal <strong>in</strong>s<strong>tru</strong>c<strong>tio</strong>ns Design air cur<strong>ta</strong><strong>in</strong> Arcus-E<br />

12<br />

13<br />

STAVOKLIMA v.o.s.<br />

Basic <strong>in</strong>forma<strong>tio</strong>n about the service and unit ma<strong>in</strong><strong>te</strong>nance<br />

Air cur<strong>ta</strong><strong>in</strong>s Arcus (X) are made of parts of high quality, which don´t claim any special ma<strong>in</strong><strong>te</strong>nance. To reach a long<br />

life-time at the unit we recommend to do a regular ma<strong>in</strong><strong>te</strong>nance <strong>in</strong> prescribed periods accord<strong>in</strong>g to own conside<strong>ra</strong><strong>tio</strong>n<br />

of the unit runn<strong>in</strong>g and applica<strong>tio</strong>n.<br />

Quar<strong>te</strong>rly at<strong>te</strong>ndance:<br />

check the unit ancho<strong>ra</strong>ge and event. tigh<strong>te</strong>n up all screw<strong>in</strong>gs. Check also screw<strong>in</strong>gs at the outblow blades - they are<br />

accesible on the <strong>in</strong>side pla<strong>te</strong>s, tigh<strong>te</strong>n<strong>in</strong>g up of the middle blades make with turn<strong>in</strong>g of the blades (tigh<strong>te</strong>n<strong>in</strong>g up of<br />

the <strong>in</strong>side thread p<strong>in</strong>).<br />

check the space of the heat exchanger and keep clear from dirt or foreign objects (with a vacuum)<br />

check the purity of the motor body and <strong>in</strong>side or outside parts of the unit. Don´t wash the motor body! Just wipe it<br />

with a damp cloth - danger of damage the wir<strong>in</strong>g of the motor; af<strong>te</strong>r clean<strong>in</strong>g the motor don´t switch the unit on for<br />

at least 60 m<strong>in</strong> - let it dry. When wip<strong>in</strong>g the outblow blades and grill procced carefully - the blades are f<strong>ra</strong>gile -<br />

damage danger!!<br />

check unit safety security for preven<strong>tio</strong>n from electric shock <strong>in</strong> accordance with respective ČSN s<strong>ta</strong>ndards or with valid<br />

s<strong>ta</strong>ndards given for your country <strong>in</strong>cl. earth<strong>in</strong>g check<strong>in</strong>g<br />

Before all ma<strong>in</strong><strong>te</strong>nance on the unit it is necessary to switch off the power supply. Current <strong>in</strong>jury danger.<br />

All electrical work should be carried out <strong>in</strong> accordance with current regula<strong>tio</strong>ns <strong>in</strong> given country and accord<strong>in</strong>g to ČSN 12 2002<br />

and other l<strong>in</strong>ked rules. At any service <strong>in</strong><strong>te</strong>rven<strong>tio</strong>n the unit must be disconnect. Connec<strong>tio</strong>n and earth<strong>in</strong>g of electric unit or its<br />

parts has to correspond especially with ČSN 332190, 332000-5-51, 33 2000-5-54. All electrical <strong>in</strong>vestiga<strong>tio</strong>ns must be<br />

performed by a qualified electrician accord<strong>in</strong>g to the notice §6 ČBU No.50/78 law.<br />

Make <strong>in</strong>quiries at the producer or distributor about the servic<strong>in</strong>g cont<strong>ra</strong>ct. You will achieve by this a<br />

regular service and a perfect care of your bought unit.<br />

Impor<strong>ta</strong>nt warn<strong>in</strong>gs<br />

Air cur<strong>ta</strong><strong>in</strong>s are <strong>in</strong><strong>te</strong>nded for preven<strong>tio</strong>n of losses the warmth or cold, filt<strong>ra</strong><strong>tio</strong>n and heat<strong>in</strong>g event. with mix<strong>in</strong>g<br />

accessories for ventila<strong>tio</strong>n. Other usage doesn´t correspond to the de<strong>te</strong>rm<strong>in</strong>a<strong>tio</strong>n. Non-professional handl<strong>in</strong>g,<br />

encroachment <strong>in</strong>to the units and at any <strong>in</strong>curred loss the supplier will not be responsible. By us<strong>in</strong>g the units you<br />

have to follow the <strong>in</strong>s<strong>tru</strong>c<strong>tio</strong>ns <strong>in</strong> this ope<strong>ra</strong>t<strong>in</strong>g manual.<br />

Mount<strong>in</strong>g, electric assembly and modifica<strong>tio</strong>ns must be performed by sui<strong>ta</strong>ble qualified person accord<strong>in</strong>g to §6 notice<br />

78/law or accord<strong>in</strong>g to valid notices and s<strong>ta</strong>ndards for given country. Also the medium connec<strong>tio</strong>n must be performed by<br />

a qualified company.<br />

STAVOKLIMA v.o.s<br />

Horní 22 České Budějovice 37004-CZ<br />

<strong>te</strong>l: +420 387 428 990 fax: +420 387 423 610<br />

www.s<strong>ta</strong>voklima.cz E-mail:<strong>in</strong>fo@s<strong>ta</strong>voklima.cz<br />

The producer reserves the right to make changes due<br />

to market<strong>in</strong>g or produc<strong>tio</strong>n rules, without prior notice !<br />

-- 12 -- MPN-ARCUS-E-A-DITRONIC

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!