15.01.2015 Views

Brochure on the New International Calibration Standards

Brochure on the New International Calibration Standards

Brochure on the New International Calibration Standards

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Product Price Quantity $ Total SFr Total<br />

Order Form<br />

DCHA-Iso, ICS-I2 $100<br />

Name<br />

DCHA-Rho, ICS-R2 $100<br />

Tetra, ICS-T2 $100<br />

Co./Inst.<br />

DCHA-Hexa, ICS-H1 $100<br />

ICE-2 CHF 250<br />

Address<br />

GRAND TOTAL<br />

No credit cards or checks accepted.<br />

Charge for shipping CHF 15.<br />

Postal Code City<br />

Payment to Labor Veritas:<br />

Country<br />

Zürcher Kant<strong>on</strong>albank, CH-8010 Zurich<br />

Account no. 1100-00524.060<br />

Teleph<strong>on</strong>e<br />

Labor Veritas, Zürich, Engimattstrasse 11<br />

Postfach 353<br />

CH-8027 Zürich, Switzerland.<br />

Fax<br />

Ph<strong>on</strong>e: +41 (44) 283 29 30<br />

Fax: +41 (44) 201 42 49<br />

E-mail: admin@laborveritas.ch<br />

Web site: www.laborveritas.ch<br />

E-mail<br />

Internati<strong>on</strong>al<br />

Calibrati<strong>on</strong><br />

<strong>Standards</strong> for<br />

HPLC Analysis<br />

of Isomerized<br />

α-Acids<br />

Current from May 07<br />

<strong>New</strong> Internati<strong>on</strong>al Calibrati<strong>on</strong><br />

<strong>Standards</strong> for HPLC Analysis of<br />

Isomerized α-Acids<br />

In 1998, <strong>the</strong> ASBC, EBC, IoB (now IBD), and BCOJ<br />

began working toge<strong>the</strong>r toward <strong>the</strong> creati<strong>on</strong> and internati<strong>on</strong>al<br />

adopti<strong>on</strong> of a single set of HPLC standards for<br />

use in <strong>the</strong> quantitative determinati<strong>on</strong> of isomerized and<br />

reduced-isomerized α-acids in hop products and in beer.<br />

The resultant Internati<strong>on</strong>al Calibrati<strong>on</strong> <strong>Standards</strong> (ICS)<br />

were produced, analyzed, and verified for <strong>the</strong> benefit of<br />

<strong>the</strong> brewing industry by <strong>the</strong> Internati<strong>on</strong>al Subcommittee<br />

for Isomerized Hop α-Acids <strong>Standards</strong> and first released<br />

in 2001.<br />

The purity of each standard was determined using various<br />

HPLC procedures, elemental analysis, and o<strong>the</strong>r methods.<br />

The standards were later reanalyzed, using an isocratic<br />

versi<strong>on</strong> of EBC Method 7.8, following which <strong>the</strong> total<br />

c<strong>on</strong>centrati<strong>on</strong>s of <strong>the</strong> major isomerized α-acids were<br />

determined. Samples of <strong>the</strong> standards showed excellent<br />

stability even after two years at room temperature,<br />

although freezer storage is str<strong>on</strong>gly recommended. <strong>New</strong><br />

DCHA-Iso, DCHA-Rho, and Tetra standards (ICS-I2,<br />

ICS-R2 and ICS-T2) are now prepared, replacing <strong>the</strong><br />

originals that are now available <strong>on</strong>ly while stocks last.<br />

General<br />

■ These standards are deemed to have <strong>the</strong> reported compositi<strong>on</strong><br />

<strong>on</strong>ly when used according to <strong>the</strong> accompanying<br />

instructi<strong>on</strong>s for storage, handling and use, especially<br />

including chromatography by <strong>the</strong> recommended, isocratic<br />

variati<strong>on</strong> of Method EBC 7.8 (now issued as EBC 7.9).<br />

■ Compared to <strong>the</strong>se standards, samples of hop products,<br />

and <strong>the</strong> worts and beers made from <strong>the</strong>m, may c<strong>on</strong>tain<br />

substantially different proporti<strong>on</strong>s of <strong>the</strong> c<strong>on</strong>stituent<br />

isomerized α-acids. However, <strong>the</strong>se latter compounds<br />

are believed to all have quite similar extincti<strong>on</strong> coefficients<br />

at 270 nm in <strong>the</strong> mobile phase of <strong>the</strong> recommended<br />

method, hence <strong>the</strong> standards are c<strong>on</strong>sidered<br />

suitable for use in quantifying isomerized α-acids in all<br />

unknown samples.<br />

■ Detailed informati<strong>on</strong> pertaining to each standard, plus<br />

full instructi<strong>on</strong> for use, is available <strong>on</strong> request and is supplied<br />

with each purchase, including: two chromatograms<br />

of a single analysis that illustrate (1) <strong>the</strong> major peaks<br />

up<strong>on</strong> which <strong>the</strong> calibrati<strong>on</strong> must be based and (2) <strong>the</strong><br />

minor peaks that are also present in <strong>the</strong> preparati<strong>on</strong>.<br />

The spectra obtained from a photo-diode array (PDA)<br />

detector scanning at <strong>the</strong> peak maxima of all <strong>the</strong>se peaks<br />

are also included.<br />

Limitati<strong>on</strong>s<br />

■ Most HPLC methods will not reliably separate all cisand<br />

trans-isomers of <strong>the</strong> three major homologs (co-,<br />

n- & ad-) of a given type of isomerized α-acid. These<br />

standards are <strong>the</strong>refore recommended primarily for <strong>the</strong><br />

determinati<strong>on</strong> of <strong>the</strong> total c<strong>on</strong>tent of isomerized α-acids<br />

of <strong>the</strong> stated type in an unknown sample, though it may<br />

often be possible to c<strong>on</strong>currently determine <strong>the</strong> cohumul<strong>on</strong>e<br />

homologs c<strong>on</strong>tent.<br />

■ In some HPLC eluti<strong>on</strong> solvents it may be expected<br />

that <strong>the</strong> extincti<strong>on</strong> coefficients of <strong>the</strong> different isomers<br />

and homologs are not at all similar, leading to substantial<br />

errors in quantificati<strong>on</strong> of an unknown sample.<br />

Especially, this may be <strong>the</strong> case if <strong>the</strong> detector is set to<br />

an inappropriate wavelength.<br />

■ Where mixtures of different types of iso-α-acids are<br />

present, <strong>the</strong>y may not be fully resolved by some HPLC<br />

methods, leading to errors of identificati<strong>on</strong> and quantitative<br />

evaluati<strong>on</strong>.<br />

Purchasing<br />

These Iso standards can be purchased, at <strong>the</strong><br />

equivalent price, from:<br />

1. Labor Veritas, Zürich, Engimattstrasse 11<br />

Postfach 353<br />

CH-8027 Zürich, Switzerland.<br />

Ph<strong>on</strong>e: +41 (44) 283 29 30<br />

Fax: +41 (44) 201 42 49<br />

E-mail: admin@laborveritas.ch<br />

Web site: www.laborveritas.ch<br />

2. American Society of Brewing Chemists<br />

(ASBC): 3340 Pilot Knob Road<br />

St. Paul, MN 55121, USA.<br />

Ph<strong>on</strong>e: +1.651.454.7250<br />

Fax: +1.651.454.0766<br />

E-mail: asbc@scisoc.org<br />

Web site: www.asbcnet.org<br />

Orders from Europe and Africa should be directed<br />

to Labor Veritas, from North and South America to<br />

ASBC, from elsewhere to ei<strong>the</strong>r seller. LV reserves <strong>the</strong><br />

right to limit <strong>the</strong> number of vials of each<br />

standard purchased.<br />

#7697EBC-5/07


DCHA-Iso, ICS-I2<br />

DCHA-Rho, ICS-R2<br />

Tetra, ICS-T2<br />

DCHA-Hexa, ICS-H1<br />

ICS-I2 is a purified preparati<strong>on</strong> of <strong>the</strong> dicyclohexylamine<br />

salts of trans-iso-α-acids. It is deemed to have a total<br />

iso-α-acids c<strong>on</strong>tent of 64.3% (w/w), though this figure takes<br />

into account <strong>on</strong>ly <strong>the</strong> major forms of <strong>the</strong> iso-α-acids that<br />

are present: trans-isocohumul<strong>on</strong>e, trans-isohumul<strong>on</strong>e and<br />

trans-isoadhumul<strong>on</strong>e. (N.B. Worts and beers brewed with<br />

hops, hop extracts, pellets and all commercial “Iso” products<br />

invariably also c<strong>on</strong>tain substantial proporti<strong>on</strong>s of <strong>the</strong><br />

corresp<strong>on</strong>ding cis-iso-α-acids - see User’s Guide supplied<br />

with <strong>the</strong> standard).<br />

If you are using <strong>the</strong> recommended method, expect <strong>the</strong> area<br />

of <strong>the</strong> trans-isocohumul<strong>on</strong>e peak to be about 47.5% of <strong>the</strong><br />

total peak area of all of <strong>the</strong> compounds included in <strong>the</strong><br />

calibrati<strong>on</strong>. (Cauti<strong>on</strong>: This may not be <strong>the</strong> case for methods<br />

that use o<strong>the</strong>r mobile phases, or for measurement at different<br />

wavelengths).<br />

ICS-I2 replaces ICS-I1. The new standard has been<br />

cross-checked against <strong>the</strong> old and will give similar results.<br />

ICS-R2 is a purified preparati<strong>on</strong> of <strong>the</strong> dicyclohexylamine salts<br />

of cis-ρ-iso-α-acids. This standard is deemed to have a total<br />

ρ-iso-α-acids c<strong>on</strong>tent of 65.3% (w/w), though this figure takes<br />

into account <strong>on</strong>ly <strong>the</strong> major forms of <strong>the</strong> ρ-iso-α-acids that are<br />

present: two cis-ρ-isocohumul<strong>on</strong>es, two cis-ρ-isohumul<strong>on</strong>es and<br />

two cis-ρ-isoadhumul<strong>on</strong>es. (N.B. Commercial “Rho” products<br />

typically c<strong>on</strong>tain a significant proporti<strong>on</strong> of a trans-ρ-isohumul<strong>on</strong>e<br />

isomer - see User’s Guide supplied with <strong>the</strong> standard).<br />

If you are using <strong>the</strong> recommended method, expect <strong>the</strong> combined<br />

area of <strong>the</strong> cis-ρ-isocohumul<strong>on</strong>es peaks* to be about<br />

14.5% of <strong>the</strong> total peak area of all of <strong>the</strong> compounds included<br />

in <strong>the</strong> calibrati<strong>on</strong>. (Cauti<strong>on</strong>: This may not be <strong>the</strong> case for<br />

methods that use o<strong>the</strong>r mobile phases, or for measurement at<br />

different wavelengths).<br />

ICS-R2 replaces ICS-R1. The new standard has been<br />

cross-checked against <strong>the</strong> old and has an essentially identical<br />

resp<strong>on</strong>se factor per unit of total cis-ρ-iso-α-acids.<br />

* The supplied chromatogram shows two peaks, corresp<strong>on</strong>ding to<br />

<strong>the</strong> two cis forms of this particular iso-α-acid. However, it is not<br />

known which peak corresp<strong>on</strong>ds to which of <strong>the</strong> two forms shown<br />

below. (The same is also true for <strong>the</strong> ρ-isohumul<strong>on</strong>es peaks).<br />

ICS-T2 is a purified preparati<strong>on</strong> c<strong>on</strong>taining both cis- and<br />

trans-isomers of <strong>the</strong> tetrahydroisocohumul<strong>on</strong>es,<br />

tetrahydroisohumul<strong>on</strong>es and tetrahydroisoadhumul<strong>on</strong>es.<br />

In respect of <strong>the</strong>se six isomers it is deemed to have a total<br />

tetrahydroiso-α-acids c<strong>on</strong>tent of 99.4% (w/w).<br />

If you are using <strong>the</strong> recommended method, expect <strong>the</strong><br />

(combined) area of <strong>the</strong> tetrahydroisocohumul<strong>on</strong>es<br />

peak(s)* to be about 39% of <strong>the</strong> total peak area of all of<br />

<strong>the</strong> compounds included in <strong>the</strong> calibrati<strong>on</strong>. (Cauti<strong>on</strong>: This<br />

may not be <strong>the</strong> case for methods that use o<strong>the</strong>r mobile<br />

phases, or for measurement at different wavelengths).<br />

ICS-T2 replaces ICS-T1. The new standard has a much<br />

higher cis:trans ratio than <strong>the</strong> old and this may result in a<br />

small reducti<strong>on</strong> (typically 1 - 2% relative) to <strong>the</strong> value<br />

obtained for “total Tetra” in an unknown sample.<br />

* The supplied chromatogram shows <strong>on</strong>ly <strong>on</strong>e peak.<br />

However, it is often found that <strong>the</strong> two isomers of<br />

tetrahydroisocohumul<strong>on</strong>e are partially resolved.<br />

ICS-H1 is a purified preparati<strong>on</strong> of <strong>the</strong> dicyclohexylamine<br />

salts of cis-hexahydroiso-α-acids. It is deemed to have a<br />

total hexahydroiso-a-acids c<strong>on</strong>tent of 65.7% (w/w), though<br />

this figure takes into account <strong>on</strong>ly <strong>the</strong> major forms of hexahydroiso-α-acids<br />

that are present: two cis-hexahydroisocohumul<strong>on</strong>es,<br />

two cis-hexahydroisohumul<strong>on</strong>es and two<br />

cis-hexahydroisoadhumul<strong>on</strong>es.<br />

If you are using <strong>the</strong> recommended method, expect <strong>the</strong> combined<br />

areas of <strong>the</strong> cis-hexahydroisocohumul<strong>on</strong>es peaks* to<br />

be about 53% of <strong>the</strong> total peak area of all of <strong>the</strong> compounds<br />

included in <strong>the</strong> calibrati<strong>on</strong>. (Cauti<strong>on</strong>: This may not be <strong>the</strong><br />

case for methods that use o<strong>the</strong>r mobile phases, or for<br />

measurement at different wavelengths).<br />

* The supplied chromatogram shows two peaks, corresp<strong>on</strong>ding<br />

to <strong>the</strong> two cis forms of this particular iso-α-acid.<br />

However, it is not known which peak corresp<strong>on</strong>ds to which<br />

of <strong>the</strong> two forms shown above. (The same is also true for <strong>the</strong><br />

ρ-isohumul<strong>on</strong>es peaks).<br />

Structures of DCHA-Iso-alpha-acids<br />

Structures of DCHA-rho-Iso-alpha-acids<br />

Structures of Tetrahydroiso-alpha-acids<br />

Structures of DCHA-Hexahydroiso-alpha-acids<br />

H<br />

HO<br />

O<br />

O<br />

O<br />

O -<br />

H 2 N +<br />

DCHA - trans-Isocohumul<strong>on</strong>e<br />

C 32 H 51 NO 5<br />

(mw 529.751)<br />

H<br />

HO<br />

HO<br />

O<br />

O -<br />

H<br />

O<br />

R<br />

H 2 N +<br />

cis-<br />

H<br />

HO<br />

O<br />

O<br />

O<br />

OH<br />

R<br />

H<br />

HO<br />

HO<br />

O<br />

O -<br />

H<br />

O<br />

R<br />

H 2 N +<br />

O<br />

H<br />

HO<br />

O<br />

O<br />

O -<br />

H 2 N +<br />

DCHA - trans-Isohumul<strong>on</strong>e<br />

C 33 H 53 NO 5<br />

(mw 543.778)<br />

H<br />

HO<br />

HO<br />

O<br />

O -<br />

H<br />

O<br />

R<br />

H 2 N +<br />

DCHA-Rho, ICS-R2<br />

(c<strong>on</strong>tains two cis forms of<br />

each rho-iso-α-acid)<br />

trans-<br />

O<br />

H<br />

HO<br />

O<br />

O<br />

OH<br />

R<br />

Tetra, ICS-T2<br />

(c<strong>on</strong>tains both cis & trans forms of<br />

tetrahydroiso-α-acids)<br />

H<br />

HO<br />

HO<br />

O<br />

O -<br />

H<br />

O<br />

R<br />

H 2 N +<br />

DCHA-Hexa, ICS-H1<br />

(c<strong>on</strong>tains two cis forms of<br />

each hexahydroiso-α-acid)<br />

O<br />

O<br />

H<br />

HO<br />

O<br />

O -<br />

H 2 N +<br />

DCHA - trans-Isoadhumul<strong>on</strong>e<br />

C 33 H 53 NO 5<br />

(mw 543.778)<br />

DCHA-rho-isocohumul<strong>on</strong>es<br />

C 32 H 53 NO 5<br />

(mw 531.765)<br />

DCHA-rho-isohumul<strong>on</strong>es<br />

& isoadhumul<strong>on</strong>es<br />

C 33 H 55 NO 5<br />

(mw 545.791)<br />

Tetrahydroisocohumul<strong>on</strong>es<br />

C 20 H 32 O 5<br />

(mw 352.464)<br />

Tetrahydroisohumul<strong>on</strong>es &<br />

Tetrahydroisoadhumul<strong>on</strong>es<br />

C 21 H 34 O 5<br />

(mw 366.490)<br />

DCHA-hexahydroisocohumul<strong>on</strong>es<br />

C 32 H 57 NO 5<br />

(mw 535.796)<br />

DCHA-hexahydroisohumul<strong>on</strong>es<br />

& isoadhumul<strong>on</strong>es<br />

C 33 H 59 NO 5<br />

(mw 549.823)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!