Industrial Measurement and Control<br />

<strong>Honeywell</strong>’s<br />

<strong>Infrared</strong><br />

<strong>Temperature</strong><br />

<strong>Sensors</strong><br />

Key Features<br />

• 4 - 20mA Linear Output<br />

• 2-wire Connection<br />

• Through-the-lens<br />

Sighting (IRLS)<br />

• Variable Focus<br />

Distance (IRLS)<br />

• 0.5% Accuracy<br />

• Rugged Stainless<br />

Steel Design<br />

Innovative Design<br />

<strong>Honeywell</strong>’s <strong>Infrared</strong> <strong>Sensors</strong> are 2-wire temperature transducers/transmitters for non-contact<br />

temperature measurement. These products represent the latest in innovative technology, integrating<br />

exclusive, advanced electronic design with optical and mechanical precision that are the essence of<br />

<strong>Honeywell</strong>’s infrared products. The design from concept to finish is based on simplicity of installation<br />

and maintenance. The sensors, with their matchless array of options and accessories, demonstrate<br />

<strong>Honeywell</strong>’s continuing leadership in temperature measuring technology.<br />

Universal Application<br />

Completely self-contained, the IRFF and IRLS can be used as true 2-wire temperature transducer/<br />

transmitters which produce a standard 4-20mA linear output. Powered by its current loop, each<br />

sensor is completely compatible with any existing instrumentation for recording or process control. A<br />

rugged, stainless steel housing, miniature size and light weight make the sensors suitable for many<br />

applications which up to now were the exclusive domain of contact type temperature transmitters,<br />

such as thermocouples, resistance thermometers, etc. To insure minimum maintenance and utmost<br />

reliability, the sensors have absolutely no moving parts. When contained within its companion<br />

cooling jacket and air purge assembly, each sensor can withstand the most punishing conditions<br />

found in industry. The sensors have universal application in virtually any type of industry. Typical<br />

application areas where infrared has successfully been used include: cement, ceramics, chemicals,<br />

food, glass, heat treating, metals, paper, plastics, power, printing, petrochemicals, robotics, rubber,<br />

semiconductors, textiles, vacuum systems....<br />

IRFF Sensor<br />

The IRFF is designed to handle most demanding industrial applications. When powered by an 18 to<br />

40 Vdc supply, it provides a 4-20mA linear output for interface with indication and recording<br />

instrumentation. Its two-wire design simplifies installation, operation and maintenance. Screw<br />

terminals allow easy yet secure connection. The IRFF is a fixed optical system. That is, the distance<br />

between the sensor and the target area determines target size. It is recommended for applications<br />

where target size is known and operating distance is relatively constant.<br />

IRLS Sensor<br />

The IRLS contains all the features of the IRFF with the added<br />

benefit of upright through-lens sighting. The IRLS incorporates a<br />

high quality, high precision variable focus optical system that<br />

allows sharp focussing on the desired focussing knob on the rear<br />

panel of the instrument. The IRLS allows for precision pinpointing<br />

of small target areas. The user simply adjusts the instrument until<br />

the image is clear and the desired target is located within the<br />

reticle. The IRLS is available in three distinct versions. The first will<br />

make accurate measurements at distances of 14 inches to infinity,<br />

the second has a working range of 6 to 14 inches and the third is<br />

designed to measure a target at 2 inch distance.


Field Interchangeability<br />

Superior design not only insures accuracy and long term reliability,<br />

it also insures interchangeability between sensors of the same<br />

model with ±0.50% accuracy. For especially demanding<br />

applications, the sensors have a digital emissivity control, which<br />

can be set with a resolution of 0.01. This insures that, should one<br />

of the sensors need to be replaced, the replacement unit can be<br />

preset in every aspect before installation.<br />

Application Assistance<br />

Many years of experience in solving unusual and difficult<br />

temperature measurement and control problems qualify our sales<br />

and application engineering staffs to offer solutions to the most<br />

challenging applications encountered in industry.<br />

Quality Assurance<br />

Reliability is never taken for granted at <strong>Honeywell</strong>. After final<br />

calibration, every sensor is tested and burned-in for a week and<br />

rigorously subjected to a period of thermal cycling and vibration<br />

to verify calibration data.<br />

Warranty<br />

All sensors are backed by a two-year warranty and <strong>Honeywell</strong>’s<br />

Technical Assistance Center.<br />

<strong>Honeywell</strong> Industrial Measurement and Control offers a complete<br />

portfolio of products and solutions for process and machine<br />

control applications, including controllers, recorders, transmitters,<br />

actuators, smart sensors, and analytical instruments. To<br />

learn more about these offerings and how they can help your<br />

organization achieve breakthrough results, contact your local<br />

<strong>Honeywell</strong> representative, or contact us at the following phone<br />

numbers:<br />

U.S.: 1-800-784-3011<br />

France: 33 1 60 19 80 75<br />

Canada: 1-800-461-0013<br />

Italy: 39 02 9214 6503<br />

UK: 44 191 548 6305<br />

Spain: 34 91313.61.00<br />

Germany: 49 69 8064 336<br />

Latin America: 1-305-805-8188<br />

Asia/Pacific: 65 355 2828<br />

For other locations, visit our website: www.honeywell.com/imc<br />

Industrial Measurement and Control<br />

www.honeywell.com/imc<br />

Copyright © 2003 <strong>Honeywell</strong> International, Inc.<br />

Specifications<br />

Accuracy*: ± 0.5% of full scale or 1.0°C (1.80°F) whichever is greater<br />

Resolution: ± 0.1% of full scale span (FSS)<br />

Repeatability: ± 0.2% of full scale span (FSS)<br />

Emissivity: Digital setting 0.10 to 0.99 with 0.01 step<br />

Optical System: IRLS: Non-paralex refractive optics focusable<br />

from rear panel<br />

Field of View: IRLS: Visual sighting 40. <strong>Infrared</strong> measurement definition<br />

MTS (see FOV diagram) for IRFF & optical resolution for IRLS<br />

Focussing Distance: IRLS: The different versions cover 2 inches<br />

to infinity (adjustable for sharp focussing on target)<br />

Eyepiece: IRLS: Dioper type<br />

Input voltage: 24 Vdc nominal (range: 18-40 Vdc)<br />

Output Current Span: 4-20 mA linear standard<br />

Min. Output Current: 3.8 mA<br />

Max. Output Current: 32 mA<br />

Response Time: 50mS for Spectral Response of 0.78-1.6 microns<br />

100 mS for all others. Response time defined as time required for<br />

output to reach 95% of its final value.<br />

Load Resistance Max: 400 ohms for 24 Vdc input voltage,<br />

1200 ohms for 40 Vdc input voltage<br />

Electrical Connections: IRFF: Two terminal screws molded into high<br />

strength, high temperature thermoplastic<br />

Electrical Connections: IRLS: Four terminal compression type<br />

Operating Ambient <strong>Temperature</strong><br />

Without Cooling Jacket: 00 to 600°C (320 to 1400°F)<br />

Without Air Purge Assembly: 1200°C (2500°F) rated for water-cooling<br />

With Cooling Jacket: Up to 3150°C (6000°F)<br />

Storage Ambient <strong>Temperature</strong>: -300 to 800°C (-200 to 1600°F)<br />

Relative Humidity: 90% Non-condensing<br />

Vibration: IRFF: 3 g’s any Axis Continuous<br />

Shock: IRFF: 50 g’s<br />

Housing Material: Stainless Steel<br />

Dimensions: IRFF: 2.0 x 7.8 inches (50 x 200 mm)<br />

Dimensions: IRLS: 2.0 x 8.0 inches (50 x 203 mm)<br />

Weight: 1.9 lbs. (0.9 kg)<br />

Mounting: Support block with four 0.2 inch (5 mm) diameter holes and<br />

U-clamp. For more secure mounting, protective jacket is recommended<br />

Optional Features<br />

NIST Traceable: Minimum of five points on instrument<br />

Calibration Certificate: <strong>Temperature</strong> scale. Additional points as<br />

required at extra cost per point.<br />

Peak/Valley Picker: See accessories (electrical)<br />

* Accuracy is stated for target emissivity of 1.0 at specified focussed distance<br />

and target having sufficient diameter to eliminate background influence.<br />

* Accuracy is stated for input voltage of 24 Vdc and load resistance of 250 ohms.<br />

* For a narrow band Spectral Response centered at 3.86 microns the accuracy is<br />

limited to 0.75% FS<br />