16.01.2015 Views

ESD Brochure (PDF 881.5 KB) - ERBE Elektromedizin GmbH

ESD Brochure (PDF 881.5 KB) - ERBE Elektromedizin GmbH

ESD Brochure (PDF 881.5 KB) - ERBE Elektromedizin GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

introduction<br />

<strong>ERBE</strong> TechnOLOgy<br />

Endoscopic submucosal resection spares the patient<br />

open surgery and with it possible intra- and postoperative<br />

complications. Using the EMR (endoscopic<br />

mucosal resection) and the <strong>ESD</strong> (endoscopic submucosal<br />

dissection) methods, such minimally invasive<br />

interventions have found application for the treatment<br />

of early carcinomas, adenomas and lesions in<br />

the gastrointestinal tract in general for some years.<br />

<strong>ERBE</strong> <strong>Elektromedizin</strong> has advanced the development<br />

of this precise <strong>ESD</strong> method in collaboration with<br />

leading Japanese and European experts. Safety aspects<br />

have been improved considerably, the surgical<br />

procedure has been simplified, and operating times<br />

have been reduced.<br />

Internationally renowned gastroenterologists already<br />

work using this method. More and more users<br />

convinced of its merits will adopt it, applying it for<br />

lesions of the stomach and increasingly also of the<br />

colon and the esophagus.<br />

With its VIO GI workstation, Erbe <strong>Elektromedizin</strong><br />

has established itself in the field of gastroenterology<br />

worldwide and has many years of profound know<br />

how in interventional endoscopy.<br />

The system consists of the VIO electrosurgical unit,<br />

which acts as the master module, as well as an Argon<br />

Plasma Coagulation unit for devitalizing gastrointestinal<br />

structures and coagulating diffuse bleeding.<br />

The <strong>ERBE</strong>JET 2 waterjet surgical unit is a new, additional<br />

system component for <strong>ESD</strong>.<br />

Both technologies, electrosurgery and waterjet surgery,<br />

are activated and applied using the <strong>ERBE</strong> HybridKnife as<br />

a combination instrument. For the first time, all working<br />

steps involved in the <strong>ESD</strong> procedure can be performed<br />

with just one instrument: marking of the resection margin,<br />

elevation of the mucosa, incision/dissection of the submucosa<br />

and coagulation of the resection bed.<br />

In this brochure we wish to demonstrate to you the<br />

advantages of the <strong>ESD</strong> method using the Hybrid-<br />

Knife, describe the steps involved in the procedure,<br />

and provide you with additional information and<br />

useful adviced.<br />

Medical progress never stands still. Thus we not only<br />

aim to provide what is currently the most effective,<br />

state-of-the-art procedure for endoscopic resection.<br />

We will continue to keep abreast of clinical insights<br />

and incorporate them into our research and development<br />

so that you obtain even better results in the<br />

treatment of your patients in the future.<br />

Important note<br />

<strong>ERBE</strong> <strong>Elektromedizin</strong> <strong>GmbH</strong> has taken the greatest possible<br />

care when compiling these recommendations.<br />

Nevertheless, it is impossible to exclude the possibility<br />

that errors may be contained herein. The information<br />

and recommendations given here may not be construed<br />

as constituting any basis for any claims against <strong>ERBE</strong><br />

<strong>Elektromedizin</strong> <strong>GmbH</strong>. Should legal regulations stipulate<br />

liability, such liability shall be limited to intentional<br />

misconduct or gross negligence.<br />

The data respecting recommended settings, areas of<br />

application, application duration or the use of instruments<br />

is based on clinical experience, although it is<br />

important to remember that individual centers and<br />

physicians may favor settings which differ from the recommended<br />

settings given here. All values are merely<br />

guidelines and their applicability must be verified by the<br />

operator. Depending on the circumstances, it may be<br />

necessary to deviate from the values and settings given<br />

in this brochure.<br />

Medical science is subject to a process of permanent<br />

change based on research and clinical experience. It<br />

may therefore also be appropriate to deviate from the<br />

values and settings given in this brochure on the basis<br />

of the results of such research and experience.<br />

02 HybridKnife

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!