STEP<br />

CONNECT<br />

GENERATOR<br />

TO<br />

DUMMY<br />

ANTENNA<br />

RF, IF AND MPX ALIGNMENT PROCEDURE<br />

FOR MODEL <strong>MC7051</strong> - Cont'd.<br />

CONNECT<br />

VTVM/<br />

SCOPE TO<br />

INPUT<br />

SIGNAL<br />

FREQ.<br />

SET DIAL<br />

TO<br />

ADJUST<br />

PURPOSE<br />

FM ALIGNMENT<br />

Note: For FM IF Alignment Use A Signal Of 250 KHz Deviation, 50 Hertz Modulation For Full Bandpass Display. Bandswitch In FM. Preset R208,<br />

R21 1 And R303 To Mid Rotation Before Connecting Generator. Connect Generator Cable Ground To Gang Frame.<br />

32 Shunt C1B To Ground With A .001 MF Capacitor.<br />

33<br />

34<br />

35<br />

36<br />

37<br />

Test Point "D"<br />

FM IF Input<br />

At High Side<br />

Of C1F<br />

Test Point "A"<br />

FM Antenna Post<br />

(Disconnect Antenna)<br />

Generator<br />

Output<br />

Probe<br />

"A"<br />

Scope<br />

Detector<br />

Probe "C"<br />

Test Point<br />

At IC201<br />

Pin 1.<br />

300 Ohm Scope<br />

Test Point<br />

"H"<br />

10.7 MHz Gang<br />

Closed<br />

Tune Generator To Center Total Bandpass<br />

Waveform. Do Not Change Generator Frequency<br />

For Remainder Of FM IF Alignment.<br />

Center Freq.<br />

Of Ceramic<br />

Filters Y201,<br />

Y202, Y203<br />

Gang<br />

Closed<br />

T1<br />

Align I.F. Transformer For<br />

Maximum Output And Symmetry<br />

As Indicated In Scope Pattern<br />

"A".<br />

98 MHz 98 MHz<br />

R216 Adjust For No Sound Output<br />

When Input Is Below 1.7/iV With<br />

Mute Switch ON.<br />

R215 Adjust For A Reading Of 4 To 5<br />

One Meter M1 02 With Input Of<br />

60dBV (1mV).<br />

NOTE: For FM Detector Alignment Use A Signal Of 75 KHz Deviation, 1 KHz Modulation. Also Connect Generator Modulation Frequency To<br />

Scope Horizontal. Adjust Generator IF Frequency To Center Total Bandpass Waveform. Do Not Change Generator IF Frequency For<br />

Remainder Of IF Alignment. (If Your Generator Does Not Provide Output For Audio Modulation Frequency Use Horizontal Output From<br />

Generator, Or Scope Horizontal Sweep, And Follow Step 38C). Minimum Distortion Can Only Be Achieved By Use Of Step 38A Below.<br />

38<br />

39<br />

Test Point "D"<br />

FM IF<br />

Input<br />

At High Side<br />

Of C1F<br />

Generator<br />

Output<br />

Probe<br />

"A"<br />

A. Distortion<br />

Analyzer<br />

(Thru A 100<br />

Usee Deemphasis<br />

Network)<br />

Probe "B"<br />

And Scope.<br />

B.Scope<br />

C.Scope<br />

Test Point<br />

"H"<br />

Center<br />

Frequency<br />

Of Ceramic<br />

Filters Y201,<br />

Y202, Y203.<br />

Gang<br />

Closed<br />

L204, L205<br />

(T201)<br />

L205<br />

A. Preferred Method: Distortion<br />

Analyzer At Test Point "H"<br />

Should Read Minimum Distortion.<br />

B. Alternate Method: Adjust For<br />

Linear Scope Trace-No Curve At Ends<br />

Of Trace. Disregard Meter Reading.<br />

C. Alternate Method: Adjust For<br />

Maximum Length And Symmetry,<br />

Similar To Scope Pattern "A".<br />

Adjust For Center Reading On<br />

Tuning Meter M101.<br />

40 Test Point "A" 300 Ohm<br />

106 MHz 1 06 MHz C1H Set Oscillator To Dial Scale.<br />

41 FM Antenna Post<br />

42<br />

43<br />

44<br />

45<br />

<strong>46</strong><br />

47<br />

(Disconnect Antenna)<br />

48 Audio Osc. — Test Point<br />

"F"<br />

49 Test Point "H"<br />

90 MHz 90 MHz L7<br />

Repeat Steps 40 & 41 For Minimum Change.<br />

106 MHz 1 06 MHz C1D, C1F Align FM Detector Stage For<br />

90 MHz 90 MHz L3, L4<br />

Maximum.<br />

106 MHz 106 MHz C1B Align FM Antenna Stage For<br />

Maximum.<br />

90 MHz 90 MHz L2 If Necessary<br />

Repeat Steps 43 Thru <strong>46</strong> For Minimum Change.<br />

200 KHz<br />

T301 Align For Minimum.<br />

NOTE : Apply Sufficient Signal Level — Approx. 1 00 Microvolts — To Obtain Full Limiting At Point Near 98 MHz.<br />

Frequency Unmodulated<br />

R308 A. Frequency Counter Should<br />

50<br />

Counter And/<br />

Or Scope<br />

RF Carrier<br />

Read 19 KHz, + 100 Hz.<br />

51<br />

52<br />

Test Point<br />

"M"<br />

Scope And/Or<br />

AC VTVM<br />

Left Tape<br />

Output<br />

Right Tape<br />

Output.<br />

NOTE: Do Not Readjust Control R308 After Step 50.<br />

98 MHz<br />

1 0% Pilot<br />

(L+R)<br />

(L-R)<br />

(L Only)<br />

T302<br />

R318<br />

B. Alternate Method: Connect Test<br />

Point "M" Signal To Scope Vertical<br />

And An Accurate 19 KHz Signal<br />

To Scope Horizontal Input. Adjust<br />

For One Square Synchronized<br />

Waveform.<br />

Adjust For Separation.<br />

Maximum Left Output.<br />

— Check For Separation. Minimum<br />

Right Output.<br />

COLOR<br />

CODE<br />

CERAMIC FILTERS<br />

NOMINAL CENTER<br />

FREQUENCY<br />

FREQUENCY<br />

RANGE<br />

Black 10.64 MHz 10.61 to 10.67 MHz<br />

Blue 10.67 MHz 10.64 to 10.70 MHz<br />

Red 10.70 MHz 10.67 to 10.73 MHz<br />

Orange 10.73 MHz 10.70 to 10.76 MHz<br />

White 10.76 MHz 10.73 to 10.79 MHz<br />

15