EDUS39-802A-R1_a<br />

Dimensions<br />

RXYQ168, 192, 216, 240PTJU<br />

Model Name<br />

RXYQ144PYDN<br />

RXYQ168PYDN<br />

RXYQ192PYDN<br />

RXYQ216PYDN<br />

RXYQ240PYDN<br />

RXYQ168PTJU<br />

RXYQ192PTJU<br />

RXYQ216PTJU<br />

RXYQ240PTJU<br />

REYQ144PYDN<br />

REYQ168PYDN<br />

REYQ192PYDN<br />

REYQ216PYDN<br />

REYQ240PYDN<br />

REYQ168PTJU<br />

REYQ192PTJU<br />

REYQ216PTJU<br />

REYQ240PTJU<br />

11-13/16 or more<br />

(Front)<br />

25/32 13/32 or more<br />

or more<br />

19-11/16 or more<br />

59-1/16 h 2<br />

< Front ><br />

< Suction side ><br />

19-11/16 h 1<br />

4-19/32 × 7/8-mm-Oblong holes 31-3/16<br />

(Foundation bolt hole) (Pitch of foundation<br />

bolt holes)<br />

31-3/16<br />

(Pitch of foundation<br />

bolt holes)<br />

4-19/32×7/8-mm-Oblong holes<br />

(Foundation bolt hole)<br />

Outdoor Unit 1 Drawing No. Outdoor Unit 2 Drawing No.<br />

RXYQ72PYDN 3D058616 RXYQ72PYDN 3D058616<br />

RXYQ72PYDN 3D058616 RXYQ96PYDN 3D058616<br />

RXYQ72PYDN 3D058616 RXYQ120PYDN 3D058616<br />

RXYQ96PYDN 3D058616 RXYQ120PYDN 3D058616<br />

RXYQ120PYDN 3D058616 RXYQ120PYDN 3D058616<br />

RXYQ72PTJU 3D058616 RXYQ96PTJU 3D058616<br />

RXYQ72PTJU 3D058616 RXYQ120PTJU 3D058616<br />

RXYQ96PTJU 3D058616 RXYQ120PTJU 3D058616<br />

RXYQ120PTJU 3D058616 RXYQ120PTJU 3D058616<br />

REMQ72PYDN 3D058617 REMQ72PYDN 3D058617<br />

REMQ72PYDN 3D058617 REMQ96PYDN 3D058617<br />

REMQ72PYDN 3D058617 REMQ120PYDN 3D058617<br />

REMQ96PYDN 3D058617 REMQ120PYDN 3D058617<br />

REMQ120PYDN 3D058617 REMQ120PYDN 3D058617<br />

REMQ72PTJU 3D058617 REMQ96PTJU 3D058617<br />

REMQ72PTJU 3D058617 REMQ120PTJU 3D058617<br />

REMQ96PTJU 3D058617 REMQ120PTJU 3D058617<br />

REMQ120PTJU 3D058617 REMQ120PTJU 3D058617<br />

(Pitch of foundation<br />

bolt holes)<br />

Outdoor Unit 1<br />

Outdoor Unit 2<br />

66-1/8<br />

28-7/16 ~ 29-1/32<br />

Notes :<br />

1. Heights of walls<br />

Front : 59-1/16in<br />

Suction side : 19-11/16in<br />

Side : Height unrestricted<br />

36-5/8<br />

25/32 or more<br />

36-5/8<br />

30-1/8<br />

The installation space shown in this figure is based on the condition of cooling operation at the outdoor<br />

air temperature of 95˚F.<br />

The installation space of suction side shown above must be expanded in the following case.<br />

· Design outdoor temperature becomes over 95˚F.<br />

· Operating over Max. operating load (In case of causing a heavy heating load at indoor unit side)<br />

2. If the above wall heights are exceeded then h2/2 and h1/2 should be added to the<br />

front and suction side service spaces respectively as shown in the following figure.<br />

3. When installing the units the most appropriate pattern should be selected from those shown above<br />

in order to obtain the best fit in the space available always bearing in mind the need to leave enough room<br />

for a parson to pass between units and wall and for the air to circulate freely.<br />

(If more units are to be installed than are catered for in the above patterns your layout should take account<br />

of the possibility of short circuits. )<br />

4. The units should be installed to leave sufficient space at the front for the on site refrigerant piping work<br />

to be carried out comfortably.<br />

13/32 or more<br />

3D059677<br />

RXYQ-P <strong>Heat</strong> <strong>Pump</strong> (<strong>208</strong>-<strong>230V</strong>) 7