Transition Plan


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

1-Pedestrian Ramps:<br />

East Entrance to<br />

College Building South.<br />

60" x 60" min. top landing. NOTE: When a ramp<br />

leads directly to a door that swings out into the<br />

top landing area the top landing must measure<br />

a minimum 42"+ the door width. 2% maximum<br />

slope in any direction at bottom landing.<br />

Requires<br />

engineering/architectural<br />

evaluation.<br />

2 $7,115.62<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

2-Ramp Handrails: East<br />

Entrance to College<br />

Building South.<br />

1-1/4" to 1-1/2" grip portion diameter or cross<br />

section equivalent. 34" - 38" finish height above<br />

ramp surface to top of handrails. 12" minimum<br />

level extension beyond top and bottom of ramp,<br />

parallel to the floor or ground surface. The<br />

extensions extend the minimum 12" required<br />

distance (parallel to the floor or ground surface)<br />

before they are returned. Handrail has smooth<br />

surface with no sharp edges.<br />

Raise existing handrail height. 2 $3,429.87<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

3-Stairways: East<br />

Entrance to College<br />

Building South.<br />

5-Doors: East Entrance<br />

to College Building<br />

South at Ground Level.<br />

All steps have uniform riser height and tread<br />

width. Ext. - Top landing and all steps have<br />

color striping minimum 2" wide and a maximum<br />

4" wide parallel to, and not more than 1"<br />

maximum from tread nose or landing.<br />

Door hardware is operable with a single effort<br />

(lever type, panic bar or push pull type). 3<br />

seconds minimum for door closer to close from<br />

70 degree position to within 3" of the latch<br />

[ADAAG 404.2.8.1 Door & gate closers require<br />

a 5 second minimum closing time from open<br />

position of 90 degree to 12 degree position].<br />

Bottom 10" of door (except automatic or sliding<br />

doors) has a smooth uninterrupted surface that<br />

allows door to be opened by a wheelchair<br />

footrest without creating a trap or hazardous<br />

condition (kick plate).<br />

Provide a directional sign at<br />

the top and bottom of stairs<br />

indicating pedestrian ramp<br />

access.<br />

Remove the gate at top of<br />

stairs..<br />

1 $367.50<br />

2 $245.01<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

8-Doors: East Entrance<br />

to College Building<br />

South at Ground Level.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2. 5 lb. maximum pressure to operate<br />

exterior doors.<br />

Replace or modify the<br />

threshold. Adjust door opening<br />

pressure / closing time unless<br />

accepted by DSA Fire / Life<br />

Safety. Consider issues<br />

connected with building<br />

pressure / climate control.<br />

1 $551.26<br />

5/31/2012 Page 1 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

10-Signage: College<br />

Building South<br />

Throughout Ground<br />

Level.<br />

11-Floors and Levels:<br />

College Building South<br />

at Ground Level.<br />

14-Visual/Audible<br />

Alarms: At Ground Level<br />

of College Building<br />

South.<br />

15-Electrical Controls &<br />

Receptacles/Fire Alarm<br />

Boxes: Lobby Room<br />

#100 at Ground Level.<br />

Permanent I.D. signs, when provided, are<br />

installed on the wall adjacent to the latch side of<br />

the door NOTE: At double leaf doors, and when<br />

there is no room on the latch side, signs shall<br />

be placed on the nearest adjacent wall,<br />

preferably on the right.<br />

Carpets or carpet tiles are securely attached<br />

and do not exceed 1/2" in height. Carpet's<br />

exposed edges are fastened to floor surfaces<br />

and have trim along entire length.<br />

The alarm is integrated into the building or<br />

facility alarm system.<br />

The center of electrical receptacles or controls,<br />

and switches to control lighting, heating, cooling<br />

& appliances are 48" max. above the floor or<br />

working platform. The center of electrical outlets<br />

intended to be used by the room occupant are<br />

located a min. of 15" above the floor or working<br />

platform.<br />

Install permanent ID sign to<br />

latch side of door.<br />

1 $2,388.80<br />

Secure loose doormat. 1 $1,225.03<br />

Requires<br />

engineering/architectural<br />

evaluation.<br />

Lower electrical control or<br />

other switch. Raise electrical<br />

receptacle.<br />

1 $7,115.62<br />

3 $4,508.46<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

16-Stairways: South<br />

Entrance at Ground<br />

Level.<br />

17-Stairway Handrails:<br />

South Entrance at<br />

Ground Level.<br />

All risers are closed. All steps have uniform riser<br />

height and tread width. Ext. - Top landing and<br />

all steps have color striping minimum 2" wide<br />

and a maximum 4" wide parallel to, and not<br />

more than 1" maximum from tread nose or<br />

landing.<br />

Handrails are provided on both sides and are<br />

continuous for the full length of the stairway. 1-<br />

1/4" to 1-1/2" handgrip portion or cross section<br />

equivalent or the shape provides an equivalent<br />

gripping surface. Rails are 34" - 38" above stair<br />

nosing. 12" plus one tread width level extension<br />

beyond bottom nosing (parallel with the ground<br />

or floor surface) before being returned.<br />

Install slip-resistant color<br />

contrast striping to steps.<br />

Install new wall-mounted<br />

handrails. Install new freestanding<br />

handrails.<br />

1 $6,465.66<br />

3 $2,656.27<br />

5/31/2012 Page 2 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

18-Doors: South<br />

Entrance at Ground<br />

Level.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2. 5 lb. maximum pressure to operate<br />

exterior doors.<br />

Requires<br />

engineering/architectural<br />

evaluation. Adjust door<br />

opening pressure / closing<br />

time unless accepted by DSA<br />

Fire / Life Safety. Consider<br />

issues connected with building<br />

pressure / climate control.<br />

3 $7,421.88<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

19-Clear Space at<br />

Doors: South Entrance<br />

at Ground Level. [See<br />

Sequence #18 for<br />

additional actions.]<br />

22-Identification<br />

Symbols, Restrooms:<br />

Men's Restroom at the<br />

South End of the<br />

Building at Ground<br />

Level.<br />

23-Single<br />

Accommodation Toilet:<br />

Men's Restroom at the<br />

South End of the<br />

Building at Ground<br />

Level. [Relocate the<br />

filing cabinet.]<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach. Minimum strike side clearance<br />

on PUSH side of door: 12" front approach with<br />

latch and closer.<br />

Door mounted signage: Men's - Equilateral<br />

triangle with 12" sides, 1/4" thick with the vertex<br />

pointing up. The triangle symbol contrasts with<br />

the door, light on dark background or dark on<br />

light background. Wall mounted signage:<br />

Symbol of accessibility is mounted on wall sign<br />

adjacent to latch side of door [ADAAG 703.6.1<br />

& CBC 1117B.5.5 Item 4 Pictograms shall have<br />

a field height of 6" ADAAG 703.6.1 Characters<br />

and Braille shall not be located in the pictogram<br />

field].<br />

60" minimum diameter turning circle, or a T-<br />

shaped clear space, is provided in room with<br />

12" maximum door encroachment into the<br />

required clear space. 18" between centerline of<br />

water closet and side wall or partition [ADAAG<br />

604.2 16" - 18" to centerline of water closet]. 42"<br />

min. clearance between centerline of water<br />

closet and opposite wall. A minimum 60" wide<br />

and 48" deep clear floor space is provided in<br />

front of water closet. The top of the toilet seat is<br />

17" - 19" from the floor surface measured to the<br />

top of a maximum 2" high toilet seat (a 3" high<br />

seat shall be permitted only in alterations where<br />

the existing fixture is less than 15" high).<br />

Remove door latch and/or<br />

door closer.<br />

Install door-mounted sign on<br />

single door. Install wallmounted<br />

sign at single<br />

entrance.<br />

Requires<br />

engineering/architectural<br />

evaluation. Replace water<br />

closet. Provide a toilet seat to<br />

comply with the maximum<br />

height requirement of 17" -<br />

19". Relocate furniture to<br />

provide clear space. University<br />

staff shall be instructed to<br />

place and maintain the<br />

placement of furniture to<br />

provide a clear path of travel<br />

and avoid the obstruction of<br />

accessible required clear<br />

spaces.<br />

3 $245.01<br />

3 $367.51<br />

3 $10,550.25<br />

5/31/2012 Page 3 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

24-Toilet Grab Bars:<br />

Men's Restroom at the<br />

South End of the<br />

Building at Ground<br />

Level.<br />

25-Lavatories: Men's<br />

Restroom at the South<br />

End of the Building at<br />

Ground Level.<br />

26-Accessories: Men's<br />

Restroom at the South<br />

End of the Building at<br />

Ground Level. [See<br />

Sequence #24 for<br />

additional actions.]<br />

27-Electrical Controls &<br />

Receptacles/Fire Alarm<br />

Boxes: Men's Restroom<br />

at the South End of the<br />

Building at Ground<br />

Level.<br />

The rear grab bar is securely attached and is<br />

mounted at 33" to the center of the bar above<br />

and parallel to the floor (for tank type toilets, 36"<br />

may be allowed if tank obstructs placement of<br />

bar within 1-1/2" between the grab bar and the<br />

top of the tank). Side bar begins a max. of 12"<br />

from back wall. Area directly above grab bars or<br />

proposed grab bars is free of protruding<br />

obstructions to a height of 18" (recessed items<br />

are allowed).<br />

18" minimum from center of fixture to side wall<br />

or partition. 27" high x 8" deep knee clearance<br />

under front lip. Drain and piping is insulated or<br />

configured to prevent contact.<br />

40" max. height to all other fixtures (i.e., soap<br />

dispensers, towels, toilet seat covers, auto<br />

dryers, sanitary napkins, waste recepatacles,<br />

etc.).<br />

The center of electrical receptacles or controls,<br />

and switches to control lighting, heating, cooling<br />

& appliances are 48" max. above the floor or<br />

working platform. The center of electrical outlets<br />

intended to be used by the room occupant are<br />

located a min. of 15" above the floor or working<br />

platform.<br />

Relocate both grab bars.<br />

Relocate the toilet paper<br />

dispenser away from the top of<br />

the grab bar.<br />

Relocate existing lavatory.<br />

Insulate pipes under lavatory.<br />

Lower the paper towel<br />

dispenser. Lower the soap<br />

dispenser.<br />

Lower electrical control or<br />

other switch. Raise electrical<br />

receptacle.<br />

3 $612.51<br />

3 $3,091.26<br />

3 $245.01<br />

3 $2,709.63<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

29-Clear Space at<br />

Doors: Room #109 at<br />

Ground Level.<br />

31-Clear Space at<br />

Doors: Between Rooms<br />

#107 and #105 at<br />

Ground Level.<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach.<br />

Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

Relocate existing counter to<br />

provide minimum strike-side<br />

clearance.<br />

1M $122.51<br />

2 $3,012.02<br />

5/31/2012 Page 4 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

32-Sales and Service<br />

Counters: Room #105 at<br />

Ground Level.<br />

33-Sinks: Room #105 at<br />

Ground Level.<br />

A portion of the counter is a minimum of 36" in<br />

length, at a height between 28" - 34" above the<br />

floor and;<br />

Minimum 30" x 48" clear space is provided in<br />

front of sink that allows forward approach. 34"<br />

maximum height of rim or counter above floor<br />

surfaces. Sink is a maximum of 6-1/2" deep.<br />

Knee clearance under sink is a minimum of 27"<br />

high and 30" wide, and provides an absolute<br />

depth of 19" underneath the sink [ADAAG 606.2<br />

Exception 6 The dip of the overflow shall not be<br />

considered in determining knee and toe<br />

clearance]. Drain and hot water piping is<br />

insulated or configured to prevent contact.<br />

Install accessible counter. 2 $1,592.53<br />

Replace with accessible sink.<br />

Insulate pipes under sink.<br />

3 $3,430.07<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

34-Seating, Tables and<br />

Work Surfaces: Room<br />

#105 at Ground Level.<br />

30" x 48" min. clear floor space is provided. 27"<br />

high, 30" wide and 19" deep knee clearance<br />

provided.<br />

Provide accessible table. 1M $245.01 Until such time as<br />

accessible<br />

furniture / stations<br />

are available in<br />

this room staff<br />

shall be informed<br />

of the immediate<br />

availability of<br />

accessible<br />

furniture / stations<br />

that may be<br />

placed in the<br />

room to meet the<br />

needs of people<br />

with disabilities.<br />

5/31/2012 Page 5 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

36-Aisles: Room #105 at<br />

Ground Level. [Relocate<br />

the table to provide clear<br />

width.]<br />

37-Electrical Controls &<br />

Receptacles/Fire Alarm<br />

Boxes: Room #105 at<br />

Ground Level.<br />

38-Doors: Door to the<br />

South Stairwell at<br />

Ground Level.<br />

39-Clear Space at<br />

Doors: Door to the<br />

South Stairwell at<br />

Ground Level.<br />

40-Stairways: South<br />

Stairwell at Ground<br />

Level.<br />

41-Stairway Handrails:<br />

South Stairwell at<br />

Ground Level.<br />

36" minimum width of aisles. Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

The center of electrical receptacles or controls,<br />

and switches to control lighting, heating, cooling<br />

& appliances are 48" max. above the floor or<br />

working platform.<br />

Lower electrical control or<br />

other switch.<br />

32" minimum clear width of doorway. Replace door(s) and frame<br />

(stud wall).<br />

Floor or landing is level and clear (2% max.<br />

slope). 60" min. clear space in direction of door<br />

swing. 44" min. clear space opposite direction of<br />

door swing (48" with latch and closer).<br />

All risers are closed. 11" min. tread width. Int. -<br />

Top landing and lower tread have color striping<br />

minimum 2" wide and a maximum 4" wide<br />

parallel to, and not more than 1" maximum from<br />

tread nose or landing.<br />

Handrails are provided on both sides and are<br />

continuous for the full length of the stairway. 1-<br />

1/4" to 1-1/2" handgrip portion or cross section<br />

equivalent or the shape provides an equivalent<br />

gripping surface. 1-1/2" clearance provided<br />

between rail and wall. 12" minimum level<br />

extension beyond top nosing (parallel with the<br />

ground or floor surface) before being returned.<br />

12" plus one tread width level extension beyond<br />

bottom nosing (parallel with the ground or floor<br />

surface) before being returned.<br />

Requires<br />

engineering/architectural<br />

evaluation.<br />

Replace existing steps. Install<br />

slip-resistant color contrast<br />

striping to steps.<br />

Install new wall-mounted<br />

handrails.<br />

1M $61.25<br />

3 $7,240.86<br />

2 $3,136.07<br />

2 $7,115.62<br />

1 $10,104.07<br />

3 $4,904.66<br />

5/31/2012 Page 6 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

42-Stairway Signage:<br />

South Stairwell at<br />

Ground Level.<br />

43-Hazards: South<br />

Stairwell at Ground<br />

Level.<br />

44-Sales and Service<br />

Counters: Room #118 at<br />

Ground Level.<br />

45-Aisles: Room #118 at<br />

Ground Level.<br />

46-Controls, Operating<br />

Mechanisms & Vending<br />

Machines.: Room #118<br />

at Ground Level. [Coat<br />

rack / hook.]<br />

Tactile identification signage is located at each<br />

floor level in all enclosed stairways in buildings<br />

two or more stories in height.<br />

Any obstrution that overhangs a pedestrian way<br />

is a minimum 80" above the walking surface<br />

(measured from the bottom of the obstruction).<br />

Sidewalks are clear of hazards. If vertical<br />

clearance of an area adjoining an accessible<br />

route is reduced to less than 80", a barrier to<br />

warn blind or visually impaired persons is<br />

provided.<br />

A portion of the counter is a minimum of 36" in<br />

length, at a height between 28" - 34" above the<br />

floor and; A minimum 30" x 48" clear floor space<br />

is provided at the counter and;<br />

Install new signage at stairwell. 1 $490.00<br />

Requires<br />

engineering/architectural<br />

evaluation.<br />

Install accessible counter.<br />

Relocate furniture to provide<br />

clear space. University staff<br />

shall be instructed to place<br />

and maintain the placement of<br />

furniture to provide a clear<br />

path of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

36" minimum width of aisles. Relocate fixed shelving to<br />

comply with minimum required<br />

aisle width(s) listed above.<br />

Forward Reach to Objects: Highest operable<br />

part of object is a maximum of 48" above the<br />

floor surface.<br />

3 $0.00<br />

2 $1,653.79<br />

2 $980.02<br />

Install accessible coat hook. 3 $122.51<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

47-Electrical Controls &<br />

Receptacles/Fire Alarm<br />

Boxes: Room #118 at<br />

Ground Level.<br />

48-Doors: Office Room<br />

#116 at Ground Level.<br />

The center of electrical receptacles or controls,<br />

and switches to control lighting, heating, cooling<br />

& appliances are 48" max. above the floor or<br />

working platform.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2.<br />

Lower electrical control or<br />

other switch.<br />

Replace or modify the<br />

threshold.<br />

3 $5,430.64<br />

1 $245.01<br />

5/31/2012 Page 7 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

51-Clear Space at<br />

Doors: Between Rooms<br />

#118 and #100 at<br />

Ground Level.<br />

52-Doors: Room #114 at<br />

Ground Level.<br />

56-Protruding Objects:<br />

Room #114 at Ground<br />

Level. [Fireplace.]<br />

57-Electrical Controls &<br />

Receptacles/Fire Alarm<br />

Boxes: Room #114 at<br />

Ground Level.<br />

58-Doors: Between<br />

Rooms #112 and #114<br />

at Ground Level.<br />

59-Clear Space at<br />

Doors: Between Rooms<br />

#112 and #114 at<br />

Ground Level.<br />

60-Doors: Between<br />

Room #112 and Hall<br />

Entrance at Ground<br />

Level.<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2.<br />

Objects projecting from walls (i.e. telephones,<br />

etc.) have 4" maximum projection into walks,<br />

halls, corridors, passageways or aisles if lower<br />

edge of object is above 27" and below 80".<br />

The center of electrical outlets intended to be<br />

used by the room occupant are located a min.<br />

of 15" above the floor or working platform.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2.<br />

Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

Replace or modify the<br />

threshold.<br />

Install cane detectable barrier<br />

below object.<br />

1M $122.51<br />

1 $245.01<br />

1 $245.01<br />

Raise electrical receptacle. 3 $899.41<br />

Replace or modify the<br />

threshold.<br />

60" min. clear space in direction of door swing. Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2.<br />

Replace or modify the<br />

threshold.<br />

1 $245.01<br />

1M $61.25<br />

1 $245.01<br />

5/31/2012 Page 8 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

62-Seating, Tables and<br />

Work Surfaces: Room<br />

#112 at Ground Level.<br />

30" x 48" min. clear floor space is provided. 27"<br />

high, 30" wide and 19" deep knee clearance<br />

provided.<br />

Provide accessible table. 1M $245.01 Until such time as<br />

accessible<br />

furniture / stations<br />

are available in<br />

this room staff<br />

shall be informed<br />

of the immediate<br />

availability of<br />

accessible<br />

furniture / stations<br />

that may be<br />

placed in the<br />

room to meet the<br />

needs of people<br />

with disabilities.<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

63-Electrical Controls &<br />

Receptacles/Fire Alarm<br />

Boxes: Room #112 at<br />

Ground Level.<br />

64-Doors: Women's<br />

Restroom Left of Room<br />

#103 at Ground Level.<br />

65-Clear Space at<br />

Doors: Women's<br />

Restroom Left of Room<br />

#103 at Ground Level.<br />

The center of electrical outlets intended to be<br />

used by the room occupant are located a min.<br />

of 15" above the floor or working platform.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2.<br />

60" min. clear space in direction of door swing.<br />

44" min. clear space opposite direction of door<br />

swing (48" with latch and closer).<br />

Raise electrical receptacle. 4 $899.41<br />

Replace or modify the<br />

threshold.<br />

Requires<br />

engineering/architectural<br />

evaluation. Relocate furniture<br />

to provide clear space.<br />

University staff shall be<br />

instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear<br />

path of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

1 $245.01<br />

3 $61.25<br />

5/31/2012 Page 9 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

66-Identification<br />

Symbols, Restrooms:<br />

Women's Restroom Left<br />

of Room #103 at<br />

Ground Level.<br />

Women's - 12" diameter circle 1/4" thick. The<br />

circle symbol contrasts with the door, light on<br />

dark background or dark on light background.<br />

Wall mounted signage: Symbol of accessibility<br />

is mounted on wall sign adjacent to latch side of<br />

door [ADAAG 703.6.1 & CBC 1117B.5.5 Item 4<br />

Pictograms shall have a field height of 6"<br />

ADAAG 703.6.1 Characters and Braille shall not<br />

be located in the pictogram field].<br />

Install door-mounted sign on<br />

single door. Install wallmounted<br />

sign at single<br />

entrance.<br />

3 $367.51<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

67-Single<br />

Accommodation Toilet:<br />

Women's Restroom Left<br />

of Room #103 at<br />

Ground Level.<br />

60" minimum diameter turning circle, or a T-<br />

shaped clear space, is provided in room with<br />

12" maximum door encroachment into the<br />

required clear space. 42" min. clearance<br />

between centerline of water closet and opposite<br />

wall. A minimum 60" wide and 48" deep clear<br />

floor space is provided in front of water closet.<br />

The top of the toilet seat is 17" - 19" from the<br />

floor surface measured to the top of a maximum<br />

2" high toilet seat (a 3" high seat shall be<br />

permitted only in alterations where the existing<br />

fixture is less than 15" high).<br />

Replace water closet. Relocate<br />

furniture to provide clear<br />

space. University staff shall be<br />

instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear<br />

path of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

3 $3,246.31<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

68-Toilet Grab Bars:<br />

Women's Restroom Left<br />

of Room #103 at<br />

Ground Level.<br />

69-Lavatories: Women's<br />

Restroom Left of Room<br />

#103 at Ground Level.<br />

70-Accessories:<br />

Women's Restroom Left<br />

of Room #103 at<br />

Ground Level.<br />

72-Stairways: North<br />

Stairway.<br />

Side bar begins a max. of 12" from back wall.<br />

Area directly above grab bars or proposed grab<br />

bars is free of protruding obstructions to a<br />

height of 18" (recessed items are allowed).<br />

27" high x 8" deep knee clearance under front<br />

lip. Drain and piping is insulated or configured to<br />

prevent contact.<br />

40" max. height to all other fixtures (i.e., soap<br />

dispensers, towels, toilet seat covers, auto<br />

dryers, sanitary napkins, waste recepatacles,<br />

etc.).<br />

All risers are closed. Int. - Top landing and<br />

lower tread have color striping minimum 2" wide<br />

and a maximum 4" wide parallel to, and not<br />

more than 1" maximum from tread nose or<br />

landing.<br />

Relocate side grab bar.<br />

Relocate the toilet paper<br />

dispenser away from the top of<br />

the grab bar.<br />

Raise existing lavatory.<br />

Insulate pipes under lavatory.<br />

Lower the paper towel<br />

dispenser.<br />

Install slip-resistant color<br />

contrast striping to steps.<br />

3 $367.51<br />

3 $2,450.05<br />

3 $122.51<br />

1 $176.42<br />

5/31/2012 Page 10 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

73-Stairway Handrails:<br />

North Stairway.<br />

74-Stairway Signage:<br />

North Stairway.<br />

75-Water Fountains<br />

(Drinking): At the Hall<br />

Entrance at Ground<br />

Level.<br />

76-Stairways: North<br />

Entrance at Ground<br />

Level.<br />

77-Stairway Handrails:<br />

North Entrance at<br />

Ground Level.<br />

Handrails are provided on both sides and are<br />

continuous for the full length of the stairway. 12"<br />

minimum level extension beyond top nosing<br />

(parallel with the ground or floor surface) before<br />

being returned. 12" plus one tread width level<br />

extension beyond bottom nosing (parallel with<br />

the ground or floor surface) before being<br />

returned.<br />

Tactile identification signage is located at each<br />

floor level in all enclosed stairways in buildings<br />

two or more stories in height.<br />

18" - 19" depth of fountain. 27" high x 8" deep<br />

clear knee space under fountain. 9" high x 17"<br />

deep toe clearance. Bubbler outlet is 36"<br />

maximum from floor. Stream of bubbler is<br />

parallel to front edge. Two fountains are<br />

provided, one that is wheelchair accessible and<br />

one at normal height for those persons having<br />

difficulty bending or stooping.<br />

All risers are closed. 11" min. tread width. Int. -<br />

Top landing and lower tread have color striping<br />

minimum 2" wide and a maximum 4" wide<br />

parallel to, and not more than 1" maximum from<br />

tread nose or landing.<br />

Handrails are provided on both sides and are<br />

continuous for the full length of the stairway.<br />

Install new wall-mounted<br />

handrails. Install new freestanding<br />

handrails.<br />

2 $5,902.83<br />

Install new signage at stairwell. 1 $490.00<br />

Install new HI-LO drinking<br />

fountain.<br />

Install slip-resistant color<br />

contrast striping to steps.<br />

Install new wall-mounted<br />

handrails.<br />

2 $6,973.31 Defer.<br />

1 $58.80<br />

2 $980.94<br />

5/31/2012 Page 11 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

79-Doors: North<br />

Entrance at Ground<br />

Level.<br />

80-Clear Space at<br />

Doors: North Entrance<br />

at Ground Level.<br />

81-Stairways: Exterior<br />

North Entrance at<br />

Ground Level.<br />

82-Stairway Handrails:<br />

Exterior North Entrance<br />

at Ground Level.<br />

83-Doors: Room #104 at<br />

Ground Level.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2. 5 lb. maximum pressure to operate<br />

exterior doors. Door hardware is operable with a<br />

single effort (lever type, panic bar or push pull<br />

type). The international symbol of accessibility<br />

is posted at all primary entrances.<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach. Minimum strike side clearance<br />

on PUSH side of door: 12" front approach with<br />

latch and closer.<br />

All steps have uniform riser height and tread<br />

width. Ext. - Top landing and all steps have<br />

color striping minimum 2" wide and a maximum<br />

4" wide parallel to, and not more than 1"<br />

maximum from tread nose or landing.<br />

Handrails are provided on both sides and are<br />

continuous for the full length of the stairway.<br />

Rails are 34" - 38" above stair nosing. 12" plus<br />

one tread width level extension beyond bottom<br />

nosing (parallel with the ground or floor surface)<br />

before being returned.<br />

Bottom 10" of door (except automatic or sliding<br />

doors) has a smooth uninterrupted surface that<br />

allows door to be opened by a wheelchair<br />

footrest without creating a trap or hazardous<br />

condition (kick plate).<br />

Replace or modify the<br />

threshold. Adjust door opening<br />

pressure / closing time unless<br />

accepted by DSA Fire / Life<br />

Safety. Consider issues<br />

connected with building<br />

pressure / climate control.<br />

Replace door hardware with<br />

compliant hardware. Post a<br />

sign/decal displaying the<br />

"International Symbol of<br />

Accessibility" at the primary<br />

entrance. Install level exterior<br />

door landing.<br />

Remove door latch and/or<br />

door closer. See Sequence<br />

#79 for additional actions.<br />

Install slip-resistant color<br />

contrast striping to steps.<br />

Install new wall-mounted<br />

handrails. Install new freestanding<br />

handrails.<br />

1 $2,278.84<br />

2 $245.01<br />

1 $558.62<br />

2 $7,628.09<br />

Remove door stop. 1 $61.25<br />

5/31/2012 Page 12 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

84-Clear Space at<br />

Doors: Room #104 at<br />

Ground Level.<br />

86-Aisles: Room #104 at<br />

Ground Level.<br />

87-Electrical Controls &<br />

Receptacles/Fire Alarm<br />

Boxes: Room #104 at<br />

Ground Level.<br />

89-Clear Space at<br />

Doors: Room #104 at<br />

Ground Level.<br />

90-Signage: Room #104<br />

at Ground Level.<br />

Floor or landing is level and clear (2% max.<br />

slope). 60" min. clear space in direction of door<br />

swing. Minimum strike side clearance on PULL<br />

side of door: 18" wide x 60" depth at interior<br />

doors, front approach. Minimum strike side<br />

clearance on PUSH side of door: 12" front<br />

approach with latch and closer.<br />

Requires<br />

engineering/architectural<br />

evaluation. Relocate furniture<br />

to provide clear space.<br />

University staff shall be<br />

instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear<br />

path of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

Remove door latch and/or<br />

door closer.<br />

2 $7,483.13<br />

36" minimum width of aisles. Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

1M $61.25<br />

The center of electrical outlets intended to be Raise electrical receptacle. 4 $899.41<br />

used by the room occupant are located a min.<br />

of 15" above the floor or working platform.<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach.<br />

Mounting height is 60" from the finish floor to<br />

the centerline of the sign.<br />

Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

1M $245.01<br />

Relocate existing signage. 3 $980.02<br />

5/31/2012 Page 13 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

91-Doors: Men's<br />

Restroom in Room #104<br />

at Ground Level.<br />

92-Clear Space at<br />

Doors: Men's Restroom<br />

in Room #104 at Ground<br />

Level.<br />

93-Identification<br />

Symbols, Restrooms:<br />

Men's Restroom in<br />

Room #104 at Ground<br />

Level.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2. 32" minimum clear width of doorway. 5<br />

lb. maximum pressure to operate interior doors.<br />

3 seconds minimum for door closer to close<br />

from 70 degree position to within 3" of the latch<br />

[ADAAG 404.2.8.1 Door & gate closers require<br />

a 5 second minimum closing time from open<br />

position of 90 degree to 12 degree position].<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach.<br />

Wall mounted signage: Symbol of accessibility<br />

is mounted on wall sign adjacent to latch side of<br />

door [ADAAG 703.6.1 & CBC 1117B.5.5 Item 4<br />

Pictograms shall have a field height of 6"<br />

ADAAG 703.6.1 Characters and Braille shall not<br />

be located in the pictogram field].<br />

Replace or modify the<br />

threshold. Adjust door opening<br />

pressure / closing time unless<br />

accepted by DSA Fire / Life<br />

Safety. Consider issues<br />

connected with building<br />

pressure / climate control.<br />

Replace door(s) and frame<br />

(stud wall).<br />

Relocate furniture to provide<br />

clear space. University staff<br />

shall be instructed to place<br />

and maintain the placement of<br />

furniture to provide a clear<br />

path of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

Relocate existing trash<br />

receptacle to provide required<br />

clearance.<br />

Install wall-mounted sign at<br />

single entrance.<br />

1 $3,687.33<br />

3 $306.26<br />

3 $183.75<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

94-Single<br />

Accommodation Toilet:<br />

Men's Restroom in<br />

Room #104 at Ground<br />

Level. [Used as storage.<br />

Provide clear space by<br />

relocating all storage.]<br />

60" minimum diameter turning circle, or a T-<br />

shaped clear space, is provided in room with<br />

12" maximum door encroachment into the<br />

required clear space. A minimum 60" wide and<br />

48" deep clear floor space is provided in front of<br />

water closet. The top of the toilet seat is 17" -<br />

19" from the floor surface measured to the top<br />

of a maximum 2" high toilet seat (a 3" high seat<br />

shall be permitted only in alterations where the<br />

existing fixture is less than 15" high).<br />

Provide a toilet seat to comply<br />

with the maximum height<br />

requirement of 17" - 19". Move<br />

boxes, carts, non-fixed trash<br />

receptacles, etc. to provide<br />

required minimum door swing<br />

and/or clear space.<br />

3 $188.30<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

95-Toilet Grab Bars:<br />

Men's Restroom in<br />

Room #104 at Ground<br />

Level. [Two grab bars.]<br />

Area directly above grab bars or proposed grab<br />

bars is free of protruding obstructions to a<br />

height of 18" (recessed items are allowed).<br />

Relocate the seat cover<br />

dispenser away from the top of<br />

the grab bar. Relocate the<br />

toilet paper dispenser away<br />

from the top of the grab bar.<br />

3 $245.01<br />

5/31/2012 Page 14 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

96-Lavatories: Men's<br />

Restroom in Room #104<br />

at Ground Level.<br />

97-Accessories: Men's<br />

Restroom in Room #104<br />

at Ground Level. [See<br />

Sequence #95 for<br />

additional actions.]<br />

99-Doors: Women's<br />

Restroom in Room #104<br />

at Ground Level.<br />

27" high x 8" deep knee clearance under front<br />

lip. Drain and piping is insulated or configured to<br />

prevent contact.<br />

40" maximum height to bottom of reflective<br />

surface of mirror. Mirrors not located above<br />

lavatories or counters are required to measure<br />

no greater than 35" above the finished floor. 40"<br />

max. height to all other fixtures (i.e., soap<br />

dispensers, towels, toilet seat covers, auto<br />

dryers, sanitary napkins, waste recepatacles,<br />

etc.).<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2. 5 lb. maximum pressure to operate<br />

interior doors.<br />

Raise existing lavatory.<br />

Insulate pipes under lavatory.<br />

Lower mirror. Lower the paper<br />

towel dispenser.<br />

Replace or modify the<br />

threshold. Adjust door opening<br />

pressure / closing time unless<br />

accepted by DSA Fire / Life<br />

Safety. Consider issues<br />

connected with building<br />

pressure / climate control.<br />

3 $2,450.05<br />

3 $245.01<br />

1 $551.26<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

100-Clear Space at<br />

Doors: Women's<br />

Restroom in Room #104<br />

at Ground Level.<br />

101-Identification<br />

Symbols, Restrooms:<br />

Women's Restroom in<br />

Room #104 at Ground<br />

Level.<br />

60" min. clear space in direction of door swing. Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

Wall mounted signage: Symbol of accessibility<br />

is mounted on wall sign adjacent to latch side of<br />

door [ADAAG 703.6.1 & CBC 1117B.5.5 Item 4<br />

Pictograms shall have a field height of 6"<br />

ADAAG 703.6.1 Characters and Braille shall not<br />

be located in the pictogram field].<br />

Install wall-mounted sign at<br />

single entrance.<br />

1M $61.25<br />

3 $183.75<br />

5/31/2012 Page 15 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

102-Single<br />

Accommodation Toilet:<br />

Women's Restroom in<br />

Room #104 at Ground<br />

Level. [See Sequence<br />

#100 for additional<br />

recommendations.]<br />

60" minimum diameter turning circle, or a T-<br />

shaped clear space, is provided in room with<br />

12" maximum door encroachment into the<br />

required clear space. A minimum 60" wide and<br />

48" deep clear floor space is provided in front of<br />

water closet. The top of the toilet seat is 17" -<br />

19" from the floor surface measured to the top<br />

of a maximum 2" high toilet seat (a 3" high seat<br />

shall be permitted only in alterations where the<br />

existing fixture is less than 15" high).<br />

Relocate furniture to provide<br />

clear space. University staff<br />

shall be instructed to place<br />

and maintain the placement of<br />

furniture to provide a clear<br />

path of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces. Provide<br />

a toilet seat to comply with the<br />

maximum height requirement<br />

of 17" - 19".<br />

3 $249.56<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

103-Toilet Grab Bars:<br />

Women's Restroom in<br />

Room #104 at Ground<br />

Level. [Two bars.]<br />

104-Lavatories:<br />

Women's Restroom in<br />

Room #104 at Ground<br />

Level.<br />

105-Accessories:<br />

Women's Restroom in<br />

Room #104 at Ground<br />

Level.<br />

107-Doors: Southwest<br />

Exit Door Room #104 at<br />

Ground Level.<br />

108-Clear Space at<br />

Doors: Southwest Exit<br />

Door Room #104 at<br />

Ground Level.<br />

109-Stairways: Outside<br />

of the South Exit Door in<br />

Room #104 at Ground<br />

Level.<br />

Area directly above grab bars or proposed grab<br />

bars is free of protruding obstructions to a<br />

height of 18" (recessed items are allowed).<br />

27" high x 8" deep knee clearance under front<br />

lip.<br />

40" maximum height to bottom of reflective<br />

surface of mirror. Mirrors not located above<br />

lavatories or counters are required to measure<br />

no greater than 35" above the finished floor.<br />

5 lb. maximum pressure to operate exterior<br />

doors.<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PUSH side of<br />

door: 12" front approach with latch and closer.<br />

Ext. - Top landing and all steps have color<br />

striping minimum 2" wide and a maximum 4"<br />

wide parallel to, and not more than 1" maximum<br />

from tread nose or landing.<br />

Relocate the seat cover<br />

dispenser away from the top of<br />

the grab bar. Relocate the<br />

toilet paper dispenser away<br />

from the top of the grab bar.<br />

3 $245.01<br />

Raise existing lavatory. 3 $2,205.04<br />

Lower mirror. Lower the seat<br />

cover dispenser. Lower the<br />

paper towel dispenser. Lower<br />

the toilet paper dispenser.<br />

Adjust door opening pressure /<br />

closing time unless accepted<br />

by DSA Fire / Life Safety.<br />

Consider issues connected<br />

with building pressure / climate<br />

control.<br />

Requires<br />

engineering/architectural<br />

evaluation. Remove door latch<br />

and/or door closer.<br />

Install slip-resistant color<br />

contrast striping to steps.<br />

3 $490.00<br />

3 $306.26<br />

3 $245.01<br />

1 $29.41<br />

5/31/2012 Page 16 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

111-Tactile Exit<br />

Signage: Ground Level<br />

of College Building<br />

South.<br />

112-Doors: North Exit<br />

Door in Room #104 at<br />

Ground Level.<br />

113-Clear Space at<br />

Doors: North Exit Door<br />

in Room #104 at Ground<br />

Level.<br />

117-Pedestrian Ramps:<br />

At the North Entrance at<br />

Ground Level.<br />

118-Ramp Handrails: At<br />

the North Entrance at<br />

Ground Level.<br />

119-Stairways:<br />

Northwest Stairwell.<br />

120-Stairway Handrails:<br />

Northwest Stairwell.<br />

Each grade-level exterior exit door shall be<br />

identified by a tactile sign with the word "EXIT".<br />

5 lb. maximum pressure to operate exterior<br />

doors.<br />

Minimum strike side clearance on PUSH side of<br />

door: 12" front approach with latch and closer.<br />

Ramps do not exceed allowable lengths. (40' up<br />

to 6.25%, 37.5' up to 6.67%, 30' up to 8.33%).<br />

1-1/2" between wall and handrail(s) 34" - 38"<br />

finish height above ramp surface to top of<br />

handrails. 12" minimum level extension beyond<br />

top and bottom of ramp, parallel to the floor or<br />

ground surface. The extensions extend the<br />

minimum 12" required distance (parallel to the<br />

floor or ground surface) before they are<br />

returned.<br />

Int. - Top landing and lower tread have color<br />

striping minimum 2" wide and a maximum 4"<br />

wide parallel to, and not more than 1" maximum<br />

from tread nose or landing.<br />

1-1/4" to 1-1/2" handgrip portion or cross<br />

section equivalent or the shape provides an<br />

equivalent gripping surface. Rails are 34" - 38"<br />

above stair nosing. 12" minimum level<br />

extension beyond top nosing (parallel with the<br />

ground or floor surface) before being returned.<br />

Provide compliant sign. 1 $367.51<br />

Adjust door opening pressure /<br />

closing time unless accepted<br />

by DSA Fire / Life Safety.<br />

Consider issues connected<br />

with building pressure / climate<br />

control.<br />

Remove door latch and/or<br />

door closer.<br />

Requires<br />

engineering/architectural<br />

evaluation.<br />

Replace free-standing<br />

handrails.<br />

Install color contrast striping to<br />

carpet steps.<br />

2 $306.26<br />

2 $245.01<br />

2 $7,115.62<br />

2 $3,795.56<br />

1 $137.19<br />

Raise existing handrail height. 2 $6,261.75<br />

5/31/2012 Page 17 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

121-Stairway Signage:<br />

Northwest Stairwell.<br />

122-Corridors: 2nd Floor<br />

of College Building<br />

South.<br />

123-Aisles: 2nd Floor<br />

Corridor.<br />

125-Electrical Controls &<br />

Receptacles/Fire Alarm<br />

Boxes: 2nd Floor<br />

Corridor.<br />

126-Tactile Exit<br />

Signage: 2nd Floor.<br />

127-Doors: North Exit<br />

Door on the 2nd Floor.<br />

128-Clear Space at<br />

Doors: North Exit Door<br />

on the 2nd Floor.<br />

Tactile identification signage is located at each<br />

floor level in all enclosed stairways in buildings<br />

two or more stories in height.<br />

44" minimum width for occupant loads of 10 or<br />

more.<br />

Install new signage at stairwell. 1 $490.00<br />

Requires<br />

engineering/architectural<br />

evaluation. Relocate furniture<br />

to provide clear space.<br />

University staff shall be<br />

instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear<br />

path of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

36" minimum width of aisles. Clear aisle width(s) to comply<br />

with minimum required aisle<br />

width(s) listed above.<br />

The center of electrical outlets intended to be<br />

used by the room occupant are located a min.<br />

of 15" above the floor or working platform.<br />

Each exit door that leads directly to a gradelevel<br />

exterior exit by means of a stairway or<br />

ramp is identified by a tactile exit sign that<br />

states "EXIT STAIR DOWN", "EXIT RAMP<br />

DOWN", "EXIT STAIR UP", or "EXIT RAMP<br />

UP", as appropriate.<br />

5 lb. maximum pressure to operate exterior<br />

doors.<br />

Minimum strike side clearance on PUSH side of<br />

door: 12" front approach with latch and closer.<br />

2 $61.25<br />

2 $0.00<br />

Raise electrical receptacle. 4 $2,698.24<br />

Provide compliant sign. 1 $183.75<br />

Adjust door opening pressure /<br />

closing time unless accepted<br />

by DSA Fire / Life Safety.<br />

Consider issues connected<br />

with building pressure / climate<br />

control.<br />

Remove door latch and/or<br />

door closer.<br />

2 $306.26<br />

2 $245.01<br />

5/31/2012 Page 18 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

129-Signage:<br />

Throughout the 2nd<br />

Floor.<br />

131-Clear Space at<br />

Doors: Rooms #206,<br />

#208, #205, #201, #202<br />

and #203 on the 2nd<br />

Floor.<br />

132-Signage: All Doors<br />

on the 2nd Floor.<br />

133-Doors: Women's<br />

Restroom on the 2nd<br />

Floor.<br />

135-Identification<br />

Symbols, Restrooms:<br />

Women's Restroom on<br />

the 2nd Floor.<br />

Permanent I.D. signs, when provided, are<br />

installed on the wall adjacent to the latch side of<br />

the door NOTE: At double leaf doors, and when<br />

there is no room on the latch side, signs shall<br />

be placed on the nearest adjacent wall,<br />

preferably on the right.<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach.<br />

Mounting height is 60" from the finish floor to<br />

the centerline of the sign.<br />

Bottom 10" of door (except automatic or sliding<br />

doors) has a smooth uninterrupted surface that<br />

allows door to be opened by a wheelchair<br />

footrest without creating a trap or hazardous<br />

condition (kick plate).<br />

Wall mounted signage: Symbol of accessibility<br />

is mounted on wall sign adjacent to latch side of<br />

door [ADAAG 703.6.1 & CBC 1117B.5.5 Item 4<br />

Pictograms shall have a field height of 6"<br />

ADAAG 703.6.1 Characters and Braille shall not<br />

be located in the pictogram field].<br />

Install permanent ID sign to<br />

latch side of door.<br />

1 $1,102.52<br />

Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

1M $490.00<br />

Relocate existing signage. 3 $2,450.05<br />

Install kick-plate to bottom of<br />

door.<br />

Install door-mounted sign on<br />

single door. Install wallmounted<br />

sign at single<br />

entrance.<br />

1 $98.00<br />

3 $367.51<br />

5/31/2012 Page 19 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

136-Single<br />

Accommodation Toilet:<br />

Women's Restroom on<br />

the 2nd Floor. [Remove<br />

boxes and cabinet.]<br />

60" minimum diameter turning circle, or a T-<br />

shaped clear space, is provided in room with<br />

12" maximum door encroachment into the<br />

required clear space. 18" between centerline of<br />

water closet and side wall or partition [ADAAG<br />

604.2 16" - 18" to centerline of water closet]. A<br />

minimum 60" wide and 48" deep clear floor<br />

space is provided in front of water closet. The<br />

top of the toilet seat is 17" - 19" from the floor<br />

surface measured to the top of a maximum 2"<br />

high toilet seat (a 3" high seat shall be permitted<br />

only in alterations where the existing fixture is<br />

less than 15" high).<br />

Replace water closet. Provide<br />

a toilet seat to comply with the<br />

maximum height requirement<br />

of 17" - 19". Move boxes,<br />

carts, non-fixed trash<br />

receptacles, etc. to provide<br />

required minimum door swing<br />

and/or clear space.<br />

3 $3,373.38<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

137-Toilet Grab Bars:<br />

Women's Restroom on<br />

the 2nd Floor. [Remove<br />

window seal.]<br />

138-Lavatories:<br />

Women's Restroom on<br />

the 2nd Floor.<br />

139-Accessories:<br />

Women's Restroom on<br />

the 2nd Floor.<br />

140-Doors: Rooms<br />

#200, #210, #212 and<br />

#214 on the 2nd Floor.<br />

The rear grab bar is securely attached and is<br />

mounted at 33" to the center of the bar above<br />

and parallel to the floor (for tank type toilets, 36"<br />

may be allowed if tank obstructs placement of<br />

bar within 1-1/2" between the grab bar and the<br />

top of the tank). Area directly above grab bars<br />

or proposed grab bars is free of protruding<br />

obstructions to a height of 18" (recessed items<br />

are allowed).<br />

27" high x 8" deep knee clearance under front<br />

lip. Drain and piping is insulated or configured to<br />

prevent contact.<br />

40" max. height to all other fixtures (i.e., soap<br />

dispensers, towels, toilet seat covers, auto<br />

dryers, sanitary napkins, waste recepatacles,<br />

etc.).<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2.<br />

Relocate rear grab bar.<br />

Relocate the toilet paper<br />

dispenser away from the top of<br />

the grab bar.<br />

Raise existing lavatory.<br />

Insulate pipes under lavatory.<br />

Lower the paper towel<br />

dispenser. Lower the soap<br />

dispenser.<br />

Replace or modify the<br />

threshold.<br />

3 $367.51<br />

3 $2,450.05<br />

3 $245.01<br />

1 $980.02<br />

5/31/2012 Page 20 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

141-Clear Space at<br />

Doors: Rooms #200,<br />

#210, #212 and #214 on<br />

the 2nd Floor. [Four<br />

doors.]<br />

142-Doors: Room #213<br />

on the 2nd Floor.<br />

143-Clear Space at<br />

Doors: Room #213 on<br />

the 2nd Floor.<br />

144-Doors: Room #211<br />

on the 2nd Floor.<br />

145-Clear Space at<br />

Doors: Room #211 on<br />

the 2nd Floor.<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2.<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2. 32" minimum clear width of doorway.<br />

60" min. clear space in direction of door swing.<br />

Minimum strike side clearance on PULL side of<br />

door: 18" wide x 60" depth at interior doors,<br />

front approach.<br />

Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

Replace or modify the<br />

threshold.<br />

Requires<br />

engineering/architectural<br />

evaluation. Relocate furniture<br />

to provide clear space.<br />

University staff shall be<br />

instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear<br />

path of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

Replace or modify the<br />

threshold. Replace door(s) and<br />

frame (stud wall).<br />

Requires<br />

engineering/architectural<br />

evaluation. Relocate furniture<br />

to provide clear space.<br />

University staff shall be<br />

instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear<br />

path of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

1M $306.26<br />

1 $245.01<br />

2 $61.25<br />

1 $3,381.07<br />

2 $61.25<br />

5/31/2012 Page 21 of 22


Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

146-Aisles: Room #211<br />

on the 2nd Floor.<br />

148-Doors: South<br />

Stairwell on the 2nd<br />

Floor.<br />

149-Clear Space at<br />

Doors: South Stairwell<br />

on the 2nd Floor.<br />

36" minimum width of aisles. Clear aisle width(s) to comply<br />

with minimum required aisle<br />

width(s) listed above.<br />

32" minimum clear width of doorway. Replace door(s) and frame<br />

(stud wall).<br />

60" min. clear space in direction of door swing.<br />

44" min. clear space opposite direction of door<br />

swing (48" with latch and closer). Minimum<br />

strike side clearance on PULL side of door: 18"<br />

wide x 60" depth at interior doors, front<br />

approach.<br />

Requires<br />

engineering/architectural<br />

evaluation. Relocate furniture<br />

to provide clear space.<br />

University staff shall be<br />

instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear<br />

path of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

2 $0.00<br />

2 $3,136.07<br />

2 $61.25<br />

Grand Total $209,551.39<br />

5/31/2012 Page 22 of 22


Cost Report


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

1. Pedestrian Ramps - East Entrance to College Building South.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62<br />

TOTAL EST: $7,115.62<br />

2. Ramp Handrails - East Entrance to College Building South.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Raise/Lower existing handrail height. 70 l.f. $34.43 $2,410.10 $2,651.11 $2,982.50 $3,429.87 $3,429.87<br />

TOTAL EST: $3,429.87<br />

3. Stairways - East Entrance to College Building South.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install slip-resistant color contrast striping to steps. 7 ea. $20.66 $144.62 $159.08 $178.97 $205.82 $205.82<br />

TOTAL EST: $205.82<br />

4. Stairway Handrails - East Entrance to College Building South.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Raise/Lower existing handrail height. 20 l.f. $88.00 $1,760.00 $1,936.00 $2,178.00 $2,504.70 $2,504.70<br />

Install top or bottom extensions to existing handrail. 2 ea. $103.30 $206.60 $227.26 $255.67 $294.02 $294.02<br />

TOTAL EST: $2,798.72<br />

5. Doors - East Entrance to College Building South at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Remove the gate. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

Page 1 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

8. Doors - East Entrance to College Building South at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

Adjust door for opening pressure/closing times unless accepted 1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26<br />

by DSA / Fire Life Safety.<br />

TOTAL EST: $551.27<br />

10. Signage - College Building South Throughout Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install permanent ID sign to latch side of door. 13 ea. $129.12 $1,678.56 $1,846.42 $2,077.22 $2,388.80 $2,388.80<br />

TOTAL EST: $2,388.80<br />

11. Floors and Levels - College Building South at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Secure loose doormat. 5 ea. $172.16 $860.80 $946.88 $1,065.24 $1,225.03 $1,225.03<br />

TOTAL EST: $1,225.03<br />

14. Visual/Audible Alarms - At Ground Level of College Building South.<br />

Priority: 0<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62<br />

TOTAL EST: $7,115.62<br />

15. Electrical Controls & Receptacles/Fire Alarm Boxes - Lobby Room #100 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate electrical control or other switch. 1 ea. $1,272.00 $1,272.00 $1,399.20 $1,574.10 $1,810.21 $1,810.21<br />

Relocate electrical receptacle. 3 ea. $632.00 $1,896.00 $2,085.60 $2,346.30 $2,698.24 $2,698.24<br />

TOTAL EST: $4,508.45<br />

Page 2 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

16. Stairways - South Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new stairways or steps. 7 riser $628.38 $4,398.66 $4,838.53 $5,443.35 $6,259.85 $6,259.85<br />

Install slip-resistant color contrast striping to steps. 7 ea. $20.66 $144.62 $159.08 $178.97 $205.82 $205.82<br />

TOTAL EST: $6,465.67<br />

17. Stairway Handrails - South Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new wall-mounted handrails. 9 l.f. $86.16 $775.44 $852.98 $959.60 $1,103.54 $1,103.54<br />

Install new free-standing handrails. 9 l.f. $121.23 $1,091.07 $1,200.18 $1,350.20 $1,552.73 $1,552.73<br />

TOTAL EST: $2,656.27<br />

18. Doors - South Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62<br />

Adjust door for opening pressure/closing times unless accepted 1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26<br />

by DSA / Fire Life Safety.<br />

TOTAL EST: $7,421.88<br />

19. Clear Space at Doors - South Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Remove door latch and/or door closer. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

22. Identification Symbols, Restrooms - Men’s Restroom at the South End of the Building at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install door-mounted sign on single door. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

Install wall-mounted sign at single entrance. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

TOTAL EST: $367.50<br />

Page 3 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

23. Single Accommodation Toilet - Men’s Restroom at the South End of the Building at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62<br />

Replace water closet. 1 ea. $2,238.08 $2,238.08 $2,461.89 $2,769.63 $3,185.07 $3,185.07<br />

Provide a toilet seat to comply with the maximum height requirement<br />

1 ea. $132.32 $132.32 $145.55 $163.74 $188.30 $188.30<br />

of 17” - 19”.<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $10,550.24<br />

24. Toilet Grab Bars - Men’s Restroom at the South End of the Building at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate grab bar. 2 ea. $172.16 $344.32 $378.75 $426.09 $490.00 $490.00<br />

Relocate the toilet paper dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

TOTAL EST: $612.51<br />

25. Lavatories - Men’s Restroom at the South End of the Building at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate existing lavatory. 1 ea. $2,000.00 $2,000.00 $2,200.00 $2,475.00 $2,846.25 $2,846.25<br />

Insulate pipes under lavatory (or sink when applicable). 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $3,091.26<br />

26. Accessories - Men’s Restroom at the South End of the Building at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate the paper towel dispenser / hand dryer. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

Relocate the soap dispenser. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

TOTAL EST: $245.02<br />

Page 4 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

27. Electrical Controls & Receptacles/Fire Alarm Boxes - Men’s Restroom at the South End of the Building at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate electrical control or other switch. 1 ea. $1,272.00 $1,272.00 $1,399.20 $1,574.10 $1,810.21 $1,810.21<br />

Relocate electrical receptacle. 1 ea. $632.00 $632.00 $695.20 $782.10 $899.41 $899.41<br />

TOTAL EST: $2,709.62<br />

29. Clear Space at Doors - Room #109 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 2 ea. $43.04 $86.08 $94.69 $106.53 $122.51 $122.51<br />

TOTAL EST: $122.51<br />

31. Clear Space at Doors - Between Rooms #107 and #105 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate existing counter to provide minimum strike-side clearance.<br />

1 ea. $2,116.48 $2,116.48 $2,328.13 $2,619.15 $3,012.02 $3,012.02<br />

TOTAL EST: $3,012.02<br />

32. Sales and Service Counters - Room #105 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install accessible counter. 1 ea. $1,119.04 $1,119.04 $1,230.94 $1,384.81 $1,592.53 $1,592.53<br />

TOTAL EST: $1,592.53<br />

33. Sinks - Room #105 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace/Install accessible sink. 1 ea. $2,238.08 $2,238.08 $2,461.89 $2,769.63 $3,185.07 $3,185.07<br />

Insulate pipes under lavatory (or sink when applicable). 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $3,430.08<br />

Page 5 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

34. Seating, Tables and Work Surfaces - Room #105 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Provide accessible table. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

36. Aisles - Room #105 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $61.25<br />

37. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #105 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate electrical control or other switch. 4 ea. $1,272.00 $5,088.00 $5,596.80 $6,296.40 $7,240.86 $7,240.86<br />

TOTAL EST: $7,240.86<br />

38. Doors - Door to the South Stairwell at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace door(s) and frame (stud wall). 1 ea. $2,203.65 $2,203.65 $2,424.02 $2,727.02 $3,136.07 $3,136.07<br />

TOTAL EST: $3,136.07<br />

39. Clear Space at Doors - Door to the South Stairwell at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62<br />

TOTAL EST: $7,115.62<br />

40. Stairways - South Stairwell at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Remove/Replace existing stairways or steps. 10 riser $705.86 $7,058.60 $7,764.46 $8,735.02 $10,045.27 $10,045.27<br />

Install slip-resistant color contrast striping to steps. 2 ea. $20.66 $41.32 $45.45 $51.13 $58.80 $58.80<br />

TOTAL EST: $10,104.07<br />

Page 6 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

41. Stairway Handrails - South Stairwell at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new wall-mounted handrails. 40 l.f. $86.16 $3,446.40 $3,791.04 $4,264.92 $4,904.66 $4,904.66<br />

TOTAL EST: $4,904.66<br />

42. Stairway Signage - South Stairwell at Ground Level.<br />

Priority: 0<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new signage at stairwell. 2 ea. $172.16 $344.32 $378.75 $426.09 $490.00 $490.00<br />

TOTAL EST: $490.00<br />

43. Hazards - South Stairwell at Ground Level.<br />

Priority: 1<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

TOTAL EST: $0.00<br />

44. Sales and Service Counters - Room #118 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install accessible counter. 1 ea. $1,119.04 $1,119.04 $1,230.94 $1,384.81 $1,592.53 $1,592.53<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $1,653.78<br />

45. Aisles - Room #118 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate fixed shelving to comply with minimum required aisle<br />

width(s) listed above.<br />

1 ea. $688.64 $688.64 $757.50 $852.19 $980.02 $980.02<br />

TOTAL EST: $980.02<br />

Page 7 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

46. Controls, Operating Mechanisms & Vending Machines. - Room #118 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install accessible coat hook. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

TOTAL EST: $122.51<br />

47. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #118 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate electrical control or other switch. 3 ea. $1,272.00 $3,816.00 $4,197.60 $4,722.30 $5,430.64 $5,430.64<br />

TOTAL EST: $5,430.64<br />

48. Doors - Office Room #116 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

51. Clear Space at Doors - Between Rooms #118 and #100 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 2 ea. $43.04 $86.08 $94.69 $106.53 $122.51 $122.51<br />

TOTAL EST: $122.51<br />

52. Doors - Room #114 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

56. Protruding Objects - Room #114 at Ground Level.<br />

Priority: 1<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install cane detectable barrier below object. 2 l.f. $86.08 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

Page 8 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

57. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #114 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate electrical receptacle. 1 ea. $632.00 $632.00 $695.20 $782.10 $899.41 $899.41<br />

TOTAL EST: $899.41<br />

58. Doors - Between Rooms #112 and #114 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

59. Clear Space at Doors - Between Rooms #112 and #114 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $61.25<br />

60. Doors - Between Room #112 and Hall Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

62. Seating, Tables and Work Surfaces - Room #112 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Provide accessible table. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

63. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #112 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate electrical receptacle. 1 ea. $632.00 $632.00 $695.20 $782.10 $899.41 $899.41<br />

TOTAL EST: $899.41<br />

Page 9 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

64. Doors - Women’s Restroom Left of Room #103 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

65. Clear Space at Doors - Women’s Restroom Left of Room #103 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $61.25<br />

66. Identification Symbols, Restrooms - Women’s Restroom Left of Room #103 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install door-mounted sign on single door. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

Install wall-mounted sign at single entrance. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

TOTAL EST: $367.50<br />

67. Single Accommodation Toilet - Women’s Restroom Left of Room #103 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace water closet. 1 ea. $2,238.08 $2,238.08 $2,461.89 $2,769.63 $3,185.07 $3,185.07<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $3,246.32<br />

68. Toilet Grab Bars - Women’s Restroom Left of Room #103 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate grab bar. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

Relocate the toilet paper dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

TOTAL EST: $367.52<br />

Page 10 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

69. Lavatories - Women’s Restroom Left of Room #103 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Raise/Lower existing lavatory. 1 ea. $1,549.44 $1,549.44 $1,704.38 $1,917.43 $2,205.04 $2,205.04<br />

Insulate pipes under lavatory (or sink when applicable). 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $2,450.05<br />

70. Accessories - Women’s Restroom Left of Room #103 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate the paper towel dispenser / hand dryer. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

TOTAL EST: $122.51<br />

72. Stairways - North Stairway.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install slip-resistant color contrast striping to steps. 6 ea. $20.66 $123.96 $136.36 $153.41 $176.42 $176.42<br />

TOTAL EST: $176.42<br />

73. Stairway Handrails - North Stairway.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new wall-mounted handrails. 20 l.f. $86.16 $1,723.20 $1,895.52 $2,132.46 $2,452.33 $2,452.33<br />

Install new free-standing handrails. 20 l.f. $121.23 $2,424.60 $2,667.06 $3,000.44 $3,450.51 $3,450.51<br />

TOTAL EST: $5,902.84<br />

74. Stairway Signage - North Stairway.<br />

Priority: 0<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new signage at stairwell. 2 ea. $172.16 $344.32 $378.75 $426.09 $490.00 $490.00<br />

TOTAL EST: $490.00<br />

Page 11 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

75. Water Fountains (Drinking) - At the Hall Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new HI-LO drinking fountain. 1 ea. $4,900.00 $4,900.00 $5,390.00 $6,063.75 $6,973.31 $6,973.31<br />

TOTAL EST: $6,973.31<br />

76. Stairways - North Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install slip-resistant color contrast striping to steps. 2 ea. $20.66 $41.32 $45.45 $51.13 $58.80 $58.80<br />

TOTAL EST: $58.80<br />

77. Stairway Handrails - North Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new wall-mounted handrails. 8 l.f. $86.16 $689.28 $758.21 $852.99 $980.94 $980.94<br />

TOTAL EST: $980.94<br />

79. Doors - North Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

Adjust door for opening pressure/closing times unless accepted 1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26<br />

by DSA / Fire Life Safety.<br />

Replace door hardware with compliant hardware. 1 ea. $335.71 $335.71 $369.28 $415.44 $477.76 $477.76<br />

Post a sign/decal displaying the ”International Symbol of Accessibility”<br />

1 ea. $17.22 $17.22 $18.94 $21.31 $24.51 $24.51<br />

at the primary entrance.<br />

Install level exterior door landing. 50 s.f. $17.22 $861.00 $947.10 $1,065.49 $1,225.31 $1,225.31<br />

TOTAL EST: $2,278.85<br />

80. Clear Space at Doors - North Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Remove door latch and/or door closer. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

Page 12 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

81. Stairways - Exterior North Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install slip-resistant color contrast striping to steps. 19 ea. $20.66 $392.54 $431.79 $485.76 $558.62 $558.62<br />

TOTAL EST: $558.62<br />

82. Stairway Handrails - Exterior North Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new wall-mounted handrails. 20 l.f. $86.16 $1,723.20 $1,895.52 $2,132.46 $2,452.33 $2,452.33<br />

Install new free-standing handrails. 30 l.f. $121.23 $3,636.90 $4,000.59 $4,500.66 $5,175.76 $5,175.76<br />

TOTAL EST: $7,628.09<br />

83. Doors - Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Remove door stop. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $61.25<br />

84. Clear Space at Doors - Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62<br />

Relocate furniture to provide clear space. 2 ea. $43.04 $86.08 $94.69 $106.53 $122.51 $122.51<br />

Remove door latch and/or door closer. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $7,483.14<br />

86. Aisles - Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $61.25<br />

Page 13 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

87. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate electrical receptacle. 1 ea. $632.00 $632.00 $695.20 $782.10 $899.41 $899.41<br />

TOTAL EST: $899.41<br />

89. Clear Space at Doors - Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 4 ea. $43.04 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

90. Signage - Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate existing signage. 4 ea. $172.16 $688.64 $757.50 $852.19 $980.02 $980.02<br />

TOTAL EST: $980.02<br />

91. Doors - Men’s Restroom in Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

Adjust door for opening pressure/closing times unless accepted 1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26<br />

by DSA / Fire Life Safety.<br />

Replace door(s) and frame (stud wall). 1 ea. $2,203.65 $2,203.65 $2,424.02 $2,727.02 $3,136.07 $3,136.07<br />

TOTAL EST: $3,687.34<br />

92. Clear Space at Doors - Men’s Restroom in Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

Relocate existing trash receptacle to provide required clearance. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $306.26<br />

Page 14 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

93. Identification Symbols, Restrooms - Men’s Restroom in Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install wall-mounted sign at single entrance. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

TOTAL EST: $183.75<br />

94. Single Accommodation Toilet - Men’s Restroom in Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Provide a toilet seat to comply with the maximum height requirement<br />

1 ea. $132.32 $132.32 $145.55 $163.74 $188.30 $188.30<br />

of 17” - 19”.<br />

Move boxes, carts, non-fixed trash receptacles, etc. to provide 15 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

required minimum door swing and/or clear space.<br />

TOTAL EST: $188.30<br />

95. Toilet Grab Bars - Men’s Restroom in Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate the seat cover dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

Relocate the toilet paper dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

TOTAL EST: $245.02<br />

96. Lavatories - Men’s Restroom in Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Raise/Lower existing lavatory. 1 ea. $1,549.44 $1,549.44 $1,704.38 $1,917.43 $2,205.04 $2,205.04<br />

Insulate pipes under lavatory (or sink when applicable). 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $2,450.05<br />

97. Accessories - Men’s Restroom in Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate mirror. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

Relocate the paper towel dispenser / hand dryer. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

TOTAL EST: $245.02<br />

Page 15 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

99. Doors - Women’s Restroom in Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

Adjust door for opening pressure/closing times unless accepted 1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26<br />

by DSA / Fire Life Safety.<br />

TOTAL EST: $551.27<br />

100. Clear Space at Doors - Women’s Restroom in Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $61.25<br />

101. Identification Symbols, Restrooms - Women’s Restroom in Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install wall-mounted sign at single entrance. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

TOTAL EST: $183.75<br />

102. Single Accommodation Toilet - Women’s Restroom in Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

Provide a toilet seat to comply with the maximum height requirement<br />

1 ea. $132.32 $132.32 $145.55 $163.74 $188.30 $188.30<br />

of 17” - 19”.<br />

TOTAL EST: $249.55<br />

103. Toilet Grab Bars - Women’s Restroom in Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate the seat cover dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

Relocate the toilet paper dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

TOTAL EST: $245.02<br />

Page 16 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

104. Lavatories - Women’s Restroom in Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Raise/Lower existing lavatory. 1 ea. $1,549.44 $1,549.44 $1,704.38 $1,917.43 $2,205.04 $2,205.04<br />

TOTAL EST: $2,205.04<br />

105. Accessories - Women’s Restroom in Room #104 at Ground Level.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate mirror. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

Relocate the seat cover dispenser. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

Relocate the paper towel dispenser / hand dryer. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

Relocate the toilet paper dispenser. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

TOTAL EST: $490.04<br />

107. Doors - Southwest Exit Door Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Adjust door for opening pressure/closing times unless accepted<br />

by DSA / Fire Life Safety.<br />

1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26<br />

TOTAL EST: $306.26<br />

108. Clear Space at Doors - Southwest Exit Door Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

Remove door latch and/or door closer. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

109. Stairways - Outside of the South Exit Door in Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install slip-resistant color contrast striping to steps. 1 ea. $20.66 $20.66 $22.73 $25.57 $29.41 $29.41<br />

TOTAL EST: $29.41<br />

Page 17 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

111. Tactile Exit Signage - Ground Level of College Building South.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Provide compliant sign. 2 ea. $129.12 $258.24 $284.06 $319.57 $367.51 $367.51<br />

TOTAL EST: $367.51<br />

112. Doors - North Exit Door in Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Adjust door for opening pressure/closing times unless accepted<br />

by DSA / Fire Life Safety.<br />

1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26<br />

TOTAL EST: $306.26<br />

113. Clear Space at Doors - North Exit Door in Room #104 at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Remove door latch and/or door closer. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

117. Pedestrian Ramps - At the North Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62<br />

TOTAL EST: $7,115.62<br />

118. Ramp Handrails - At the North Entrance at Ground Level.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install/Replace free-standing handrails. 22 l.f. $121.23 $2,667.06 $2,933.77 $3,300.49 $3,795.56 $3,795.56<br />

TOTAL EST: $3,795.56<br />

119. Stairways - Northwest Stairwell.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install color contrast striping to carpet steps. 4 ea. $24.10 $96.40 $106.04 $119.30 $137.19 $137.19<br />

TOTAL EST: $137.19<br />

Page 18 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

120. Stairway Handrails - Northwest Stairwell.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Raise/Lower existing handrail height. 50 l.f. $88.00 $4,400.00 $4,840.00 $5,445.00 $6,261.75 $6,261.75<br />

TOTAL EST: $6,261.75<br />

121. Stairway Signage - Northwest Stairwell.<br />

Priority: 0<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new signage at stairwell. 2 ea. $172.16 $344.32 $378.75 $426.09 $490.00 $490.00<br />

TOTAL EST: $490.00<br />

122. Corridors - 2nd Floor of College Building South.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $61.25<br />

123. Aisles - 2nd Floor Corridor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Clear aisle width(s) to comply with minimum required aisle<br />

width(s) listed above.<br />

4 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

TOTAL EST: $0.00<br />

125. Electrical Controls & Receptacles/Fire Alarm Boxes - 2nd Floor Corridor.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate electrical receptacle. 3 ea. $632.00 $1,896.00 $2,085.60 $2,346.30 $2,698.24 $2,698.24<br />

TOTAL EST: $2,698.24<br />

Page 19 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

126. Tactile Exit Signage - 2nd Floor.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Provide compliant sign. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

TOTAL EST: $183.75<br />

127. Doors - North Exit Door on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Adjust door for opening pressure/closing times unless accepted<br />

by DSA / Fire Life Safety.<br />

1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26<br />

TOTAL EST: $306.26<br />

128. Clear Space at Doors - North Exit Door on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Remove door latch and/or door closer. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

129. Signage - Throughout the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install permanent ID sign to latch side of door. 6 ea. $129.12 $774.72 $852.19 $958.71 $1,102.52 $1,102.52<br />

TOTAL EST: $1,102.52<br />

131. Clear Space at Doors - Rooms #206, #208, #205, #201, #202 and #203 on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 8 ea. $43.04 $344.32 $378.75 $426.09 $490.00 $490.00<br />

TOTAL EST: $490.00<br />

132. Signage - All Doors on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate existing signage. 10 ea. $172.16 $1,721.60 $1,893.76 $2,130.48 $2,450.05 $2,450.05<br />

TOTAL EST: $2,450.05<br />

Page 20 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

133. Doors - Women’s Restroom on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install kick-plate to bottom of door. 1 ea. $68.86 $68.86 $75.75 $85.22 $98.00 $98.00<br />

TOTAL EST: $98.00<br />

135. Identification Symbols, Restrooms - Women’s Restroom on the 2nd Floor.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install door-mounted sign on single door. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

Install wall-mounted sign at single entrance. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

TOTAL EST: $367.50<br />

136. Single Accommodation Toilet - Women’s Restroom on the 2nd Floor.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace water closet. 1 ea. $2,238.08 $2,238.08 $2,461.89 $2,769.63 $3,185.07 $3,185.07<br />

Provide a toilet seat to comply with the maximum height requirement<br />

1 ea. $132.32 $132.32 $145.55 $163.74 $188.30 $188.30<br />

of 17” - 19”.<br />

Move boxes, carts, non-fixed trash receptacles, etc. to provide 4 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

required minimum door swing and/or clear space.<br />

TOTAL EST: $3,373.37<br />

137. Toilet Grab Bars - Women’s Restroom on the 2nd Floor.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate grab bar. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

Relocate the toilet paper dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

TOTAL EST: $367.52<br />

138. Lavatories - Women’s Restroom on the 2nd Floor.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Raise/Lower existing lavatory. 1 ea. $1,549.44 $1,549.44 $1,704.38 $1,917.43 $2,205.04 $2,205.04<br />

Insulate pipes under lavatory (or sink when applicable). 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $2,450.05<br />

Page 21 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

139. Accessories - Women’s Restroom on the 2nd Floor.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate the paper towel dispenser / hand dryer. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

Relocate the soap dispenser. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

TOTAL EST: $245.02<br />

140. Doors - Rooms #200, #210, #212 and #214 on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 4 ea. $172.16 $688.64 $757.50 $852.19 $980.02 $980.02<br />

TOTAL EST: $980.02<br />

141. Clear Space at Doors - Rooms #200, #210, #212 and #214 on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate furniture to provide clear space. 5 ea. $43.04 $215.20 $236.72 $266.31 $306.26 $306.26<br />

TOTAL EST: $306.26<br />

142. Doors - Room #213 on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $245.01<br />

143. Clear Space at Doors - Room #213 on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $61.25<br />

Page 22 of 23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

144. Doors - Room #211 on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace or modify the threshold. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

Replace door(s) and frame (stud wall). 1 ea. $2,203.65 $2,203.65 $2,424.02 $2,727.02 $3,136.07 $3,136.07<br />

TOTAL EST: $3,381.08<br />

145. Clear Space at Doors - Room #211 on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $61.25<br />

146. Aisles - Room #211 on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Clear aisle width(s) to comply with minimum required aisle<br />

width(s) listed above.<br />

1 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

TOTAL EST: $0.00<br />

148. Doors - South Stairwell on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace door(s) and frame (stud wall). 1 ea. $2,203.65 $2,203.65 $2,424.02 $2,727.02 $3,136.07 $3,136.07<br />

TOTAL EST: $3,136.07<br />

149. Clear Space at Doors - South Stairwell on the 2nd Floor.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $0.00 $0.00 $0.00 $0.00 $0.00 $0.00<br />

Relocate furniture to provide clear space. 1 ea. $43.04 $43.04 $47.34 $53.26 $61.25 $61.25<br />

TOTAL EST: $61.25<br />

REPORT TOTALS: $149,100.34 $164,010.37 $184,511.67 $212,188.42 $212,188.42<br />

Page 23 of 23


Survey


Americans with Disabilities Act of 1990<br />

Site Assessment Report<br />

Report: UCR P5281 College<br />

Building South<br />

900 University Avenue<br />

Riverside, CA 92521<br />

Inspection Date: 09/15/2009<br />

Prepared for:<br />

University of California at Riverside<br />

Prepared by:<br />

National Access Consultants, LLC<br />

2321 Abbot Kinney Blvd. Suite 200<br />

Venice, California 90291<br />

(805)497-6116


Contents<br />

1. Pedestrian Ramps - East Entrance to College Building South. . . . . . . . . . . . . . . . . . . . . . . 1<br />

2. Ramp Handrails - East Entrance to College Building South. . . . . . . . . . . . . . . . . . . . . . . . 3<br />

3. Stairways - East Entrance to College Building South. . . . . . . . . . . . . . . . . . . . . . . . . . . 4<br />

4. Stairway Handrails - East Entrance to College Building South. . . . . . . . . . . . . . . . . . . . . . 5<br />

5. Doors - East Entrance to College Building South at Ground Level. . . . . . . . . . . . . . . . . . . . 7<br />

6. Clear Space at Doors - East Entrance to College Building South at Ground Level. . . . . . . . . . . 9<br />

7. Walks and Sidewalks - East Entrance to College Building South at Ground Level. . . . . . . . . . . 10<br />

8. Doors - East Entrance to College Building South at Ground Level. . . . . . . . . . . . . . . . . . . . 11<br />

9. Clear Space at Doors - East Entrance to College Building South at Ground Level. . . . . . . . . . . 13<br />

10. Signage - College Building South Throughout Ground Level. . . . . . . . . . . . . . . . . . . . . . . 15<br />

11. Floors and Levels - College Building South at Ground Level. . . . . . . . . . . . . . . . . . . . . . . 16<br />

12. Sales and Service Counters - Lobby Room #100 at Ground Level. . . . . . . . . . . . . . . . . . . . 17<br />

13. Controls, Operating Mechanisms & Vending Machines. - Lobby Room #100 at Ground Level. . . . 18<br />

14. Visual/Audible Alarms - At Ground Level of College Building South. . . . . . . . . . . . . . . . . . . 19<br />

15. Electrical Controls & Receptacles/Fire Alarm Boxes - Lobby Room #100 at Ground Level. . . . . . 20<br />

16. Stairways - South Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21<br />

17. Stairway Handrails - South Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

18. Doors - South Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

19. Clear Space at Doors - South Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

20. Doors - Men’s Restroom at the South End of the Building at Ground Level. . . . . . . . . . . . . . 28<br />

21. Clear Space at Doors - Men’s Restroom at the South End of the Building at Ground Level. . . . . 30<br />

22. Identification Symbols, Restrooms - Men’s Restroom at the South End of the Building at Ground<br />

Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

23. Single Accommodation Toilet - Men’s Restroom at the South End of the Building at Ground Level. 33<br />

24. Toilet Grab Bars - Men’s Restroom at the South End of the Building at Ground Level. . . . . . . . 35<br />

25. Lavatories - Men’s Restroom at the South End of the Building at Ground Level. . . . . . . . . . . . 37<br />

26. Accessories - Men’s Restroom at the South End of the Building at Ground Level. . . . . . . . . . . 39<br />

27. Electrical Controls & Receptacles/Fire Alarm Boxes - Men’s Restroom at the South End of the<br />

Building at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41


28. Doors - Room #109 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

29. Clear Space at Doors - Room #109 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

30. Doors - Between Rooms #107 and #105 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . 47<br />

31. Clear Space at Doors - Between Rooms #107 and #105 at Ground Level. . . . . . . . . . . . . . . 49<br />

32. Sales and Service Counters - Room #105 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . 51<br />

33. Sinks - Room #105 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<br />

34. Seating, Tables and Work Surfaces - Room #105 at Ground Level. . . . . . . . . . . . . . . . . . . 54<br />

35. Hazards - Room #105 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

36. Aisles - Room #105 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56<br />

37. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #105 at Ground Level. . . . . . . . . . 57<br />

38. Doors - Door to the South Stairwell at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . 58<br />

39. Clear Space at Doors - Door to the South Stairwell at Ground Level. . . . . . . . . . . . . . . . . . 60<br />

40. Stairways - South Stairwell at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

41. Stairway Handrails - South Stairwell at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

42. Stairway Signage - South Stairwell at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . 65<br />

43. Hazards - South Stairwell at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />

44. Sales and Service Counters - Room #118 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . 67<br />

45. Aisles - Room #118 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

46. Controls, Operating Mechanisms & Vending Machines. - Room #118 at Ground Level. . . . . . . . 69<br />

47. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #118 at Ground Level. . . . . . . . . . 70<br />

48. Doors - Office Room #116 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br />

49. Clear Space at Doors - Office Room #116 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . 73<br />

50. Doors - Between Rooms #118 and #100 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . 75<br />

51. Clear Space at Doors - Between Rooms #118 and #100 at Ground Level. . . . . . . . . . . . . . . 77<br />

52. Doors - Room #114 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79<br />

53. Clear Space at Doors - Room #114 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

54. Assistive Listening Systems - Room #114 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . 81<br />

55. Seating, Tables and Work Surfaces - Room #114 at Ground Level. . . . . . . . . . . . . . . . . . . 82<br />

56. Protruding Objects - Room #114 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

57. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #114 at Ground Level. . . . . . . . . . 84


58. Doors - Between Rooms #112 and #114 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . 85<br />

59. Clear Space at Doors - Between Rooms #112 and #114 at Ground Level. . . . . . . . . . . . . . . 87<br />

60. Doors - Between Room #112 and Hall Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . 89<br />

61. Clear Space at Doors - Between Room #112 and Hall Entrance at Ground Level. . . . . . . . . . . 91<br />

62. Seating, Tables and Work Surfaces - Room #112 at Ground Level. . . . . . . . . . . . . . . . . . . 93<br />

63. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #112 at Ground Level. . . . . . . . . . 94<br />

64. Doors - Women’s Restroom Left of Room #103 at Ground Level. . . . . . . . . . . . . . . . . . . . 95<br />

65. Clear Space at Doors - Women’s Restroom Left of Room #103 at Ground Level. . . . . . . . . . . 97<br />

66. Identification Symbols, Restrooms - Women’s Restroom Left of Room #103 at Ground Level. . . . 99<br />

67. Single Accommodation Toilet - Women’s Restroom Left of Room #103 at Ground Level. . . . . . . 100<br />

68. Toilet Grab Bars - Women’s Restroom Left of Room #103 at Ground Level. . . . . . . . . . . . . . 102<br />

69. Lavatories - Women’s Restroom Left of Room #103 at Ground Level. . . . . . . . . . . . . . . . . . 104<br />

70. Accessories - Women’s Restroom Left of Room #103 at Ground Level. . . . . . . . . . . . . . . . . 106<br />

71. Electrical Controls & Receptacles/Fire Alarm Boxes - Women’s Restroom Left of Room #103 at<br />

Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107<br />

72. Stairways - North Stairway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108<br />

73. Stairway Handrails - North Stairway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109<br />

74. Stairway Signage - North Stairway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111<br />

75. Water Fountains (Drinking) - At the Hall Entrance at Ground Level. . . . . . . . . . . . . . . . . . . 112<br />

76. Stairways - North Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114<br />

77. Stairway Handrails - North Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . 115<br />

78. Stairway Signage - North Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . 116<br />

79. Doors - North Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117<br />

80. Clear Space at Doors - North Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . 120<br />

81. Stairways - Exterior North Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . 122<br />

82. Stairway Handrails - Exterior North Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . 123<br />

83. Doors - Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

84. Clear Space at Doors - Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . 127<br />

85. Controls, Operating Mechanisms & Vending Machines. - Room #104 at Ground Level. . . . . . . . 129<br />

86. Aisles - Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130


87. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #104 at Ground Level. . . . . . . . . . 131<br />

88. Doors - Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

89. Clear Space at Doors - Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . 135<br />

90. Signage - Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137<br />

91. Doors - Men’s Restroom in Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . 139<br />

92. Clear Space at Doors - Men’s Restroom in Room #104 at Ground Level. . . . . . . . . . . . . . . . 141<br />

93. Identification Symbols, Restrooms - Men’s Restroom in Room #104 at Ground Level. . . . . . . . . 143<br />

94. Single Accommodation Toilet - Men’s Restroom in Room #104 at Ground Level. . . . . . . . . . . 144<br />

95. Toilet Grab Bars - Men’s Restroom in Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . 146<br />

96. Lavatories - Men’s Restroom in Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . 148<br />

97. Accessories - Men’s Restroom in Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . 150<br />

98. Electrical Controls & Receptacles/Fire Alarm Boxes - Men’s Restroom in Room #104 at Ground<br />

Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

99. Doors - Women’s Restroom in Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . 154<br />

100.Clear Space at Doors - Women’s Restroom in Room #104 at Ground Level. . . . . . . . . . . . . . 156<br />

101.Identification Symbols, Restrooms - Women’s Restroom in Room #104 at Ground Level. . . . . . . 158<br />

102.Single Accommodation Toilet - Women’s Restroom in Room #104 at Ground Level. . . . . . . . . 159<br />

103.Toilet Grab Bars - Women’s Restroom in Room #104 at Ground Level. . . . . . . . . . . . . . . . . 161<br />

104.Lavatories - Women’s Restroom in Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . 163<br />

105.Accessories - Women’s Restroom in Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . 165<br />

106.Electrical Controls & Receptacles/Fire Alarm Boxes - Women’s Restroom in Room #104 at Ground<br />

Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167<br />

107.Doors - Southwest Exit Door Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . 169<br />

108.Clear Space at Doors - Southwest Exit Door Room #104 at Ground Level. . . . . . . . . . . . . . . 171<br />

109.Stairways - Outside of the South Exit Door in Room #104 at Ground Level. . . . . . . . . . . . . . 173<br />

110.Stairway Handrails - Outside of the South Exit Door in Room #104 at Ground Level. . . . . . . . . 174<br />

111.Tactile Exit Signage - Ground Level of College Building South. . . . . . . . . . . . . . . . . . . . . . 176<br />

112.Doors - North Exit Door in Room #104 at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . . 178<br />

113.Clear Space at Doors - North Exit Door in Room #104 at Ground Level. . . . . . . . . . . . . . . . 180<br />

114.Elevators - College Building South. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182<br />

115.Elevator Control (Panel & Hall Call) - College Building South. . . . . . . . . . . . . . . . . . . . . . 184


116.Visual and Audible Signals For Elevators - College Building South. . . . . . . . . . . . . . . . . . . . 186<br />

117.Pedestrian Ramps - At the North Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . 187<br />

118.Ramp Handrails - At the North Entrance at Ground Level. . . . . . . . . . . . . . . . . . . . . . . . 189<br />

119.Stairways - Northwest Stairwell. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191<br />

120.Stairway Handrails - Northwest Stairwell. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

121.Stairway Signage - Northwest Stairwell. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />

122.Corridors - 2nd Floor of College Building South. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195<br />

123.Aisles - 2nd Floor Corridor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197<br />

124.Visual/Audible Alarms - 2nd Floor Corridor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199<br />

125.Electrical Controls & Receptacles/Fire Alarm Boxes - 2nd Floor Corridor. . . . . . . . . . . . . . . . 200<br />

126.Tactile Exit Signage - 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202<br />

127.Doors - North Exit Door on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203<br />

128.Clear Space at Doors - North Exit Door on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . 205<br />

129.Signage - Throughout the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207<br />

130.Doors - Rooms #206, #208, #205, #201, #202 and #203 on the 2nd Floor. . . . . . . . . . . . . 208<br />

131.Clear Space at Doors - Rooms #206, #208, #205, #201, #202 and #203 on the 2nd Floor. . . . 210<br />

132.Signage - All Doors on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212<br />

133.Doors - Women’s Restroom on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214<br />

134.Clear Space at Doors - Women’s Restroom on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . 216<br />

135.Identification Symbols, Restrooms - Women’s Restroom on the 2nd Floor. . . . . . . . . . . . . . . 218<br />

136.Single Accommodation Toilet - Women’s Restroom on the 2nd Floor. . . . . . . . . . . . . . . . . . 219<br />

137.Toilet Grab Bars - Women’s Restroom on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . 221<br />

138.Lavatories - Women’s Restroom on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223<br />

139.Accessories - Women’s Restroom on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . 225<br />

140.Doors - Rooms #200, #210, #212 and #214 on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . 226<br />

141.Clear Space at Doors - Rooms #200, #210, #212 and #214 on the 2nd Floor. . . . . . . . . . . . 228<br />

142.Doors - Room #213 on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230<br />

143.Clear Space at Doors - Room #213 on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . 232<br />

144.Doors - Room #211 on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234<br />

145.Clear Space at Doors - Room #211 on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . 236


146.Aisles - Room #211 on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238<br />

147.Controls, Operating Mechanisms & Vending Machines. - Room #211 on the 2nd Floor. . . . . . . 239<br />

148.Doors - South Stairwell on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240<br />

149.Clear Space at Doors - South Stairwell on the 2nd Floor. . . . . . . . . . . . . . . . . . . . . . . . . 242


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

1. Pedestrian Ramps - East Entrance to College Building South.<br />

Memo:<br />

Areas noted in compliance:<br />

Ramps do not exceed allowable lengths. (40’ up to 6.25%, 37.5’ up to 6.67%, 30’ up to 8.33%).<br />

8.33% maximum surface slope at ramp.<br />

2% maximum cross slope at ramp.<br />

48” minimum width required at ramp.<br />

2% maximum slope in any direction at top landing.<br />

72” minimum bottom landing in the ramp direction.<br />

Bottom landing is as wide as ramp.<br />

Finished surface is slip resistant.<br />

Handrails are provided on both sides.<br />

Outdoor ramps are designed so water does not accumulate on walking surfaces.<br />

Areas not meeting new construction standards:<br />

60” x 60” min. top landing. NOTE: When a ramp leads directly to a door that swings out into the top landing area the<br />

top landing must measure a minimum 42”+ the door width. (47” x 56”.)<br />

2% maximum slope in any direction at bottom landing. (2.4%.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

1


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-1-1 (originally 0239-400)<br />

2


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

2. Ramp Handrails - East Entrance to College Building South.<br />

Memo:<br />

Areas noted in compliance:<br />

Handrails are on both sides and continuous the full length of the ramp.<br />

250 lb. point load capacity.<br />

Handrails do not rotate in their fittings.<br />

Ends of rails are rounded or returned smoothly to floor or wall.<br />

Ramps and landings with drop offs have edge protection consisting of either a guide curb a minimum 2” in height<br />

on each side of the ramp, or a wheel guide rail centered 3” + or - 1” on each side of the ramp.<br />

Areas not meeting new construction standards:<br />

1-1/4” to 1-1/2” grip portion diameter or cross section equivalent. (2”.)<br />

34” - 38” finish height above ramp surface to top of handrails. (32-1/2” - 33” high.)<br />

12” minimum level extension beyond top and bottom of ramp, parallel to the floor or ground surface. The extensions<br />

extend the minimum 12” required distance (parallel to the floor or ground surface) before they are returned. (0”.)<br />

Handrail has smooth surface with no sharp edges. (0”.)<br />

Recommendation:<br />

Raise/Lower existing handrail height.<br />

Photo #UCR P5281 College Building South-2-1 (originally 0240-400)<br />

3


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

3. Stairways - East Entrance to College Building South.<br />

Memo:<br />

Areas noted in compliance:<br />

44” min. width if occupant load is more than 50.<br />

All treads are slip resistant.<br />

Nosing projection is less than 1-1/2”.<br />

All risers are closed.<br />

11” min. tread width.<br />

Stairs do not accumulate water.<br />

Areas not meeting new construction standards:<br />

All steps have uniform riser height and tread width. (4” - 7”.)<br />

Ext. - Top landing and all steps have color striping minimum 2” wide and a maximum 4” wide parallel to, and not<br />

more than 1” maximum from tread nose or landing. (None.)<br />

Recommendation:<br />

Install slip-resistant color contrast striping to steps.<br />

Photo #UCR P5281 College Building South-3-1 (originally 0241-400)<br />

4


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

4. Stairway Handrails - East Entrance to College Building South.<br />

Memo:<br />

Areas noted in compliance:<br />

Handrails are provided on both sides and are continuous for the full length of the stairway.<br />

Handrails do not rotate in their fittings.<br />

Wall or adjacent surface is free of sharp or abrasive elements.<br />

Ends of rails are rounded or returned smoothly to wall or floor.<br />

Handrail is smooth with no sharp edges.<br />

Areas not meeting new construction standards:<br />

1-1/4” to 1-1/2” handgrip portion or cross section equivalent or the shape provides an equivalent gripping surface. (2”.)<br />

Rails are 34” - 38” above stair nosing. (28-1/2” - 32”.)<br />

12” minimum level extension beyond top nosing (parallel with the ground or floor surface) before being returned. (0”.)<br />

12” plus one tread width level extension beyond bottom nosing (parallel with the ground or floor surface) before being<br />

returned. (0”.)<br />

Handrails do not protrude into pathways. (Protrudes 12”.)<br />

Recommendation:<br />

Raise/Lower existing handrail height.<br />

Install top or bottom extensions to existing handrail.<br />

5


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-4-1 (originally 0242-400)<br />

Photo #UCR P5281 College Building South-4-2 (originally 0244-400)<br />

6


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

5. Doors - East Entrance to College Building South at Ground Level.<br />

Memo:<br />

Gate at top of stairs.<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate exterior doors.<br />

Areas not meeting new construction standards:<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type). (No hardware.)<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch. (2 seconds.)<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate). (Non-compliant.)<br />

Recommendation:<br />

Remove the gate.<br />

Photo #UCR P5281 College Building South-5-1 (originally 0245-400)<br />

7


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-5-2 (originally 0246-400)<br />

8


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

6. Clear Space at Doors - East Entrance to College Building South at<br />

Ground Level.<br />

Memo:<br />

See Sequence #5 for recommendation.<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

Minimum strike side clearance on PULL side of door: 24” exterior doors.<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (48-1/2”.)<br />

44” min. clear space opposite direction of door swing (48” with latch and closer). (28”.)<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-6-1 (originally 0247-400)<br />

9


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

7. Walks and Sidewalks - East Entrance to College Building South at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Continuous common surface is not interrupted by steps or abrupt changes in level (less than 1/4” vertical or 1/2” beveled<br />

at 1:2).<br />

5% max. surface slope in direction of travel.<br />

2% max. cross slope.<br />

48” minimum width of walkway.<br />

Surface is slip resistant.<br />

Grid openings at gratings are 1/2” wide maximum perpendicular to direction of travel.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-7-1 (originally 0248-400)<br />

10


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

8. Doors - East Entrance to College Building South at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1”.)<br />

5 lb. maximum pressure to operate exterior doors. (8 lbs.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.<br />

Photo #UCR P5281 College Building South-8-1 (originally 0249-400)<br />

11


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-8-2 (originally 0250-400)<br />

12


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

9. Clear Space at Doors - East Entrance to College Building South at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 24” exterior doors.<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-9-1 (originally 0251-400)<br />

13


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-9-2 (originally 0252-400)<br />

14


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

10. Signage - College Building South Throughout Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Permanent I.D. signs, when provided, are installed on the wall adjacent to the latch side of the door NOTE: At double<br />

leaf doors, and when there is no room on the latch side, signs shall be placed on the nearest adjacent wall, preferably on<br />

the right. (No signage.)<br />

Recommendation:<br />

Install permanent ID sign to latch side of door.<br />

Photo #UCR P5281 College Building South-10-1 (originally 0253-400)<br />

15


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

11. Floors and Levels - College Building South at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor surface is slip resistant.<br />

Changes in level do not exceed 1/4” vertical or 1/2” with 1:2 bevel.<br />

Areas not meeting new construction standards:<br />

Carpets or carpet tiles are securely attached and do not exceed 1/2” in height. (Not secured.)<br />

Carpet’s exposed edges are fastened to floor surfaces and have trim along entire length. (Not fastened.)<br />

Recommendation:<br />

Secure loose doormat.<br />

Photo #UCR P5281 College Building South-11-1 (originally 0254-400)<br />

16


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

12. Sales and Service Counters - Lobby Room #100 at Ground Level.<br />

Memo:<br />

Not used as a counter though.<br />

Areas noted in compliance:<br />

A portion of the counter is a minimum of 36” in length, at a height between 28” - 34” above the floor and;<br />

A minimum 30” x 48” clear floor space is provided at the counter and;<br />

One full unobstructed side of the clear floor space adjoins or overlaps an accessible route.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-12-1 (originally 0255-400)<br />

17


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

13. Controls, Operating Mechanisms & Vending Machines. - Lobby Room<br />

#100 at Ground Level.<br />

Memo:<br />

Copy machine.<br />

Areas noted in compliance:<br />

Controls and operating mechanisms (handles, coin slots, openings, buttons, etc.) are operable with one hand and do not<br />

require tight grasping, pinching or twisting of the wrist to operate.<br />

Forward Reach to Objects: Minimum 30” x 48” clear floor space for forward approach is provided at object.<br />

Forward Reach to Objects: Highest operable part of object is a maximum of 48” above the floor surface.<br />

Forward Reach to Objects: Lowest operable part of object is a minimum of 15” above the floor surface.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-13-1 (originally 0256-400)<br />

18


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

14. Visual/Audible Alarms - At Ground Level of College Building South.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

The alarm is integrated into the building or facility alarm system. (No system.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Photo #UCR P5281 College Building South-14-1 (originally 0257-400)<br />

19


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

15. Electrical Controls & Receptacles/Fire Alarm Boxes - Lobby Room<br />

#100 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform. (56” high.)<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor<br />

or working platform. (9”.)<br />

Recommendation:<br />

Relocate electrical control or other switch.<br />

Relocate electrical receptacle.<br />

Photo #UCR P5281 College Building South-15-1 (originally 0258-400)<br />

20


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

16. Stairways - South Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

36” min. width if occupant load is less than 50.<br />

All treads are slip resistant.<br />

Nosing projection is less than 1-1/2”.<br />

11” min. tread width.<br />

Stairs do not accumulate water.<br />

Areas not meeting new construction standards:<br />

All risers are closed. (Nosing protrudes.)<br />

All steps have uniform riser height and tread width. (5” - 7” riser / 12-1/2” -14” tread.)<br />

Ext. - Top landing and all steps have color striping minimum 2” wide and a maximum 4” wide parallel to, and not<br />

more than 1” maximum from tread nose or landing. (No striping.)<br />

Recommendation:<br />

Install new stairways or steps.<br />

Install slip-resistant color contrast striping to steps.<br />

Photo #UCR P5281 College Building South-16-1 (originally 0259-400)<br />

21


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

17. Stairway Handrails - South Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

12” minimum level extension beyond top nosing (parallel with the ground or floor surface) before being returned.<br />

Handrails do not rotate in their fittings.<br />

Wall or adjacent surface is free of sharp or abrasive elements.<br />

Ends of rails are rounded or returned smoothly to wall or floor.<br />

Handrail is smooth with no sharp edges.<br />

Handrails do not protrude into pathways.<br />

Areas not meeting new construction standards:<br />

Handrails are provided on both sides and are continuous for the full length of the stairway. (One side only.)<br />

1-1/4” to 1-1/2” handgrip portion or cross section equivalent or the shape provides an equivalent gripping surface.<br />

(5-1/2”.)<br />

Rails are 34” - 38” above stair nosing. (32” high.)<br />

12” plus one tread width level extension beyond bottom nosing (parallel with the ground or floor surface) before being<br />

returned. (0”.)<br />

Recommendation:<br />

Install new wall-mounted handrails.<br />

Install new free-standing handrails.<br />

22


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-17-1 (originally 0260-400)<br />

23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

18. Doors - South Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (5” step.)<br />

5 lb. maximum pressure to operate exterior doors. (6 lbs.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.<br />

Photo #UCR P5281 College Building South-18-1 (originally 0261-400)<br />

24


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-18-2 (originally 0262-400)<br />

25


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

19. Clear Space at Doors - South Entrance at Ground Level.<br />

Memo:<br />

See Sequence #18 for additional recommendations.<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Areas not meeting new construction standards:<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (2-1/4”.)<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer. (4” to the wall.)<br />

Recommendation:<br />

Remove door latch and/or door closer.<br />

Photo #UCR P5281 College Building South-19-1 (originally 0263-400)<br />

26


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-19-2 (originally 0264-400)<br />

27


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

20. Doors - Men’s Restroom at the South End of the Building at Ground<br />

Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-20-1 (originally 0265-400)<br />

28


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-20-2 (originally 0266-400)<br />

29


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

21. Clear Space at Doors - Men’s Restroom at the South End of the<br />

Building at Ground Level.<br />

Memo:<br />

See Sequence #25 for recommendations.<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (15-1/2” to the lavatory.)<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-21-1 (originally 0267-400)<br />

30


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-21-2 (originally 0268-400)<br />

31


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

22. Identification Symbols, Restrooms - Men’s Restroom at the South<br />

End of the Building at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Door mounted signage: Men’s - Equilateral triangle with 12” sides, 1/4” thick with the vertex pointing up. The triangle<br />

symbol contrasts with the door, light on dark background or dark on light background. (Incorrect.)<br />

Wall mounted signage: Symbol of accessibility is mounted on wall sign adjacent to latch side of door. (None.)<br />

Recommendation:<br />

Install door-mounted sign on single door.<br />

Install wall-mounted sign at single entrance.<br />

Photo #UCR P5281 College Building South-22-1 (originally 0269-400)<br />

32


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

23. Single Accommodation Toilet - Men’s Restroom at the South End of<br />

the Building at Ground Level.<br />

Memo:<br />

Relocate the filing cabinet.<br />

Areas noted in compliance:<br />

Space for 30” x 48” wheelchair to enter and permit door to close.<br />

Privacy lock, push button, lever release.<br />

28” minimum between the side of the water closet and any fixture or a minimum of 32” clear space between the side of<br />

the water closet to opposite wall or partition.<br />

44” max. height to flush valve.<br />

Flush valve is on wide side of the water closet<br />

5 lb. max. force is required to operate the flush valve.<br />

Front of toilet paper dispenser is within 36” of the back wall.<br />

The toilet paper dispenser is located on the side wall below the grab bar and within 12” of the front of the toilet<br />

seat.<br />

19” min. height to toilet paper dispenser.<br />

Toilet paper dispenser provides continuous flow.<br />

Areas not meeting new construction standards:<br />

60” minimum diameter turning circle, or a T-shaped clear space, is provided in room with 12” maximum door encroachment<br />

into the required clear space. (54”.)<br />

18” between centerline of water closet and side wall or partition. (18-1/2”.)<br />

42” min. clearance between centerline of water closet and opposite wall. (38-1/2” to the filing cabinet.)<br />

A minimum 60” wide and 48” deep clear floor space is provided in front of water closet.<br />

swing.)<br />

(60” x 43” to the door<br />

The top of the toilet seat is 17” - 19” from the floor surface measured to the top of a maximum 2” high toilet seat<br />

(a 3” high seat shall be permitted only in alterations where the existing fixture is less than 15” high). (19-1/2” high.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Replace water closet.<br />

Provide a toilet seat to comply with the maximum height requirement of 17” - 19”.<br />

Relocate furniture to provide clear space.<br />

33


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-23-1 (originally 0270-400)<br />

34


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

24. Toilet Grab Bars - Men’s Restroom at the South End of the Building<br />

at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

1-1/4” to 1-1/2” diameter of bars.<br />

1-1/2” clearance between bars and each wall or partition.<br />

The side grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor.<br />

Side bar has 42” min. length.<br />

The front of the side grab bar extends 54” from back wall in single accommodation stall.<br />

Back bar has 36” min. length.<br />

Back bar begins a max. of 6” from side wall.<br />

Bars are smooth with a min. edge radius of 1/8”.<br />

Grab bars do not rotate within their fittings.<br />

Min. structural strength to support 250 lb. point load.<br />

Surface of wall adjacent to grab bars are free of sharp or abrasive elements.<br />

Areas not meeting new construction standards:<br />

The rear grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor (for<br />

tank type toilets, 36” may be allowed if tank obstructs placement of bar). (37-3/4” high.)<br />

Side bar begins a max. of 12” from back wall. (13”.)<br />

Area directly above grab bars or proposed grab bars is free of protruding obstructions to a height of 18” (recessed<br />

items are allowed). (Toilet paper dispenser - 7”.)<br />

Recommendation:<br />

Relocate grab bar.<br />

Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.<br />

35


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-24-1 (originally 0271-400)<br />

36


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

25. Lavatories - Men’s Restroom at the South End of the Building at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

30” x 48” min. clear space provided in front of lavatory that allows forward approach (doors may not encroach into this<br />

space).<br />

Required clear space extends 19” max. underneath the lavatory and adjoins or over laps an accessible route.<br />

34” max. height to rim or counter above floor surface.<br />

29” min. clearance from bottom of apron to floor surface.<br />

30” wide x 9” high x 17” deep clearance from front of lavatory.<br />

There are no sharp or abrasive elements under lavatory.<br />

Faucets are lever type, electronically activated or approved self closing valves (10 second open flow).<br />

Faucets are operable with one hand and do not require tight grasping, pinching or twisting of wrist.<br />

5 lb. max. force required to operate controls.<br />

Areas not meeting new construction standards:<br />

18” minimum from center of fixture to side wall or partition. (15-1/4”.)<br />

27” high x 8” deep knee clearance under front lip. (25-1/4”.)<br />

Drain and piping is insulated or configured to prevent contact. (No insulation.)<br />

Recommendation:<br />

Relocate existing lavatory.<br />

Insulate pipes under lavatory (or sink when applicable).<br />

37


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-25-1 (originally 0272-400)<br />

38


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

26. Accessories - Men’s Restroom at the South End of the Building at<br />

Ground Level.<br />

Memo:<br />

See Sequence #24 for additional recommendations.<br />

Areas noted in compliance:<br />

40” maximum height to bottom of reflective surface of mirror.<br />

height above floor surface is recom-<br />

Coat hooks and shelving are located within appropriate reach ranges (48” max.<br />

mended).<br />

Accessories do not require tight grasping, pinching or twisting of the wrist to operate.<br />

A minimum 30” x 48” minimum clear floor or ground space is provided to allow forward or parallel approach to accessories.<br />

A maximum of 5 lbs. force is required to operate mechanisms.<br />

Areas not meeting new construction standards:<br />

40” max. height to all other fixtures (i.e., soap dispensers, towels, toilet seat covers, auto dryers, sanitary napkins, waste<br />

recepatacles, etc.). (Soap dispenser - 45-1/2” / toilet paper dispenser - 41” / paper towel dispenser - 43-1/2”.)<br />

Recommendation:<br />

Relocate the paper towel dispenser / hand dryer.<br />

Relocate the soap dispenser.<br />

Photo #UCR P5281 College Building South-26-1 (originally 0273-400)<br />

39


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-26-2 (originally 0274-400)<br />

40


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

27. Electrical Controls & Receptacles/Fire Alarm Boxes - Men’s Restroom<br />

at the South End of the Building at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform. (56” high.)<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor<br />

or working platform. (3-1/2” high.)<br />

Recommendation:<br />

Relocate electrical control or other switch.<br />

Relocate electrical receptacle.<br />

Photo #UCR P5281 College Building South-27-1 (originally 0275-400)<br />

41


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-27-2 (originally 0276-400)<br />

42


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

28. Doors - Room #109 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-28-1 (originally 0277-400)<br />

43


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-28-2 (originally 0278-400)<br />

44


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

29. Clear Space at Doors - Room #109 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (36” to the furniture.)<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (9” to shelving.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-29-1 (originally 0279-400)<br />

45


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-29-2 (originally 0280-400)<br />

46


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

30. Doors - Between Rooms #107 and #105 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-30-1 (originally 0281-400)<br />

47


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-30-2 (originally 0282-400)<br />

48


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

31. Clear Space at Doors - Between Rooms #107 and #105 at Ground<br />

Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (11-1/2” to the counter.)<br />

Recommendation:<br />

Relocate existing counter to provide minimum strike-side clearance.<br />

Photo #UCR P5281 College Building South-31-1 (originally 0283-400)<br />

49


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-31-2 (originally 0284-400)<br />

50


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

32. Sales and Service Counters - Room #105 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

A minimum 30” x 48” clear floor space is provided at the counter and;<br />

One full unobstructed side of the clear floor space adjoins or overlaps an accessible route.<br />

Areas not meeting new construction standards:<br />

A portion of the counter is a minimum of 36” in length, at a height between 28” - 34” above the floor and; (36” high.)<br />

Recommendation:<br />

Install accessible counter.<br />

Photo #UCR P5281 College Building South-32-1 (originally 0285-400)<br />

51


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

33. Sinks - Room #105 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Required clear space adjoins or overlaps an accessible route.<br />

There are no sharp or abrasive elements under sink.<br />

Faucets are lever type, electronically activated or approved self-closing valves (minimum 10 second open flow).<br />

Faucets are operable with one hand and do not require tight grasping, pinching or twisting of the wrist.<br />

5 lb. maximum force required to activate controls.<br />

Areas not meeting new construction standards:<br />

Minimum 30” x 48” clear space is provided in front of sink that allows forward approach.<br />

34” maximum height of rim or counter above floor surfaces. (36” high.)<br />

Sink is a maximum of 6-1/2” deep. (7”.)<br />

Knee clearance under sink is a minimum of 27” high and 30” wide, and provides an absolute depth of 19” underneath the<br />

sink. (25” high.)<br />

Drain and hot water piping is insulated or configured to prevent contact. (No insulation.)<br />

Recommendation:<br />

Replace/Install accessible sink.<br />

Insulate pipes under lavatory (or sink when applicable).<br />

52


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-33-1 (originally 0286-400)<br />

53


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

34. Seating, Tables and Work Surfaces - Room #105 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

One full unobstructed side of clear floor space adjoins or overlaps an accessible route or another wheelchair clear floor space.<br />

28” - 34” height of table or work surface that is 36” wide.<br />

Areas not meeting new construction standards:<br />

30” x 48” min. clear floor space is provided.<br />

27” high, 30” wide and 19” deep knee clearance provided. (25-1/2”.)<br />

Recommendation:<br />

Provide accessible table.<br />

Photo #UCR P5281 College Building South-34-1 (originally 0287-400)<br />

54


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

35. Hazards - Room #105 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

If vertical clearance of an area adjoining an accessible route is reduced to less than 80”, a barrier to warn blind or visually<br />

impaired persons is provided.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-35-1 (originally 0288-400)<br />

55


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

36. Aisles - Room #105 at Ground Level.<br />

Memo:<br />

Relocate the table to provide clear width.<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

36” minimum width of aisles. (29-3/4”.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-36-1 (originally 0289-400)<br />

56


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

37. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #105 at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor or<br />

working platform.<br />

Areas not meeting new construction standards:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform. (53” - 62”.)<br />

Recommendation:<br />

Relocate electrical control or other switch.<br />

Photo #UCR P5281 College Building South-37-1 (originally 0290-400)<br />

57


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

38. Doors - Door to the South Stairwell at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

32” minimum clear width of doorway. (27” wide.)<br />

Recommendation:<br />

Replace door(s) and frame (stud wall).<br />

Photo #UCR P5281 College Building South-38-1 (originally 0291-400)<br />

58


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-38-2 (originally 0292-400)<br />

59


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

39. Clear Space at Doors - Door to the South Stairwell at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach.<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

Floor or landing is level and clear (2% max. slope). (Step.)<br />

60” min. clear space in direction of door swing. (7” step down.)<br />

44” min. clear space opposite direction of door swing (48” with latch and closer). (5” step up.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Photo #UCR P5281 College Building South-39-1 (originally 0293-400)<br />

60


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-39-2 (originally 0294-400)<br />

61


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

40. Stairways - South Stairwell at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

36” min. width if occupant load is less than 50.<br />

All treads are slip resistant.<br />

Nosing projection is less than 1-1/2”.<br />

All steps have uniform riser height and tread width.<br />

Stairs do not accumulate water.<br />

Areas not meeting new construction standards:<br />

All risers are closed. (Nosing protrudes.)<br />

11” min. tread width. (4”.)<br />

Int. - Top landing and lower tread have color striping minimum 2” wide and a maximum 4” wide parallel to, and<br />

not more than 1” maximum from tread nose or landing. (No striping.)<br />

Recommendation:<br />

Remove/Replace existing stairways or steps.<br />

Install slip-resistant color contrast striping to steps.<br />

Photo #UCR P5281 College Building South-40-1 (originally 0295-400)<br />

62


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

41. Stairway Handrails - South Stairwell at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Rails are 34” - 38” above stair nosing.<br />

Handrails do not rotate in their fittings.<br />

Wall or adjacent surface is free of sharp or abrasive elements.<br />

Ends of rails are rounded or returned smoothly to wall or floor.<br />

Handrail is smooth with no sharp edges.<br />

Handrails do not protrude into pathways.<br />

Areas not meeting new construction standards:<br />

Handrails are provided on both sides and are continuous for the full length of the stairway. (One side only.)<br />

1-1/4” to 1-1/2” handgrip portion or cross section equivalent or the shape provides an equivalent gripping surface.<br />

(2”.)<br />

1-1/2” clearance provided between rail and wall. (1-3/4”.)<br />

12” minimum level extension beyond top nosing (parallel with the ground or floor surface) before being returned. (0”.)<br />

12” plus one tread width level extension beyond bottom nosing (parallel with the ground or floor surface) before being<br />

returned. (0”.)<br />

Recommendation:<br />

Install new wall-mounted handrails.<br />

63


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-41-1 (originally 0296-400)<br />

64


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

42. Stairway Signage - South Stairwell at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Identification signage is located at each floor level in all enclosed stairways in buildings two or more stories in height. (No<br />

signage.)<br />

Recommendation:<br />

Install new signage at stairwell.<br />

Photo #UCR P5281 College Building South-42-1 (originally 0297-400)<br />

65


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

43. Hazards - South Stairwell at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Any obstrution that overhangs a pedestrian way is a minimum 80” above the walking surface (measured from the bottom<br />

of the obstruction). (78”.)<br />

Sidewalks are clear of hazards.<br />

If vertical clearance of an area adjoining an accessible route is reduced to less than 80”, a barrier to warn blind or<br />

visually impaired persons is provided. (78”.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Photo #UCR P5281 College Building South-43-1 (originally 0298-400)<br />

66


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

44. Sales and Service Counters - Room #118 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

One full unobstructed side of the clear floor space adjoins or overlaps an accessible route.<br />

Areas not meeting new construction standards:<br />

A portion of the counter is a minimum of 36” in length, at a height between 28” - 34” above the floor and; (35-1/2” high.)<br />

A minimum 30” x 48” clear floor space is provided at the counter and; (30” x 26”.)<br />

Recommendation:<br />

Install accessible counter.<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-44-1 (originally 0299-400)<br />

67


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

45. Aisles - Room #118 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

36” minimum width of aisles. (26”.)<br />

Recommendation:<br />

Relocate fixed shelving to comply with minimum required aisle width(s) listed above.<br />

Photo #UCR P5281 College Building South-45-1 (originally 0300-400)<br />

68


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

46. Controls, Operating Mechanisms & Vending Machines. - Room #118<br />

at Ground Level.<br />

Memo:<br />

Coat rack / hook.<br />

Areas noted in compliance:<br />

Controls and operating mechanisms (handles, coin slots, openings, buttons, etc.) are operable with one hand and do not<br />

require tight grasping, pinching or twisting of the wrist to operate.<br />

Forward Reach to Objects: Minimum 30” x 48” clear floor space for forward approach is provided at object.<br />

Forward Reach to Objects: Lowest operable part of object is a minimum of 15” above the floor surface.<br />

Areas not meeting new construction standards:<br />

Forward Reach to Objects: Highest operable part of object is a maximum of 48” above the floor surface. (69” high.)<br />

Recommendation:<br />

Install accessible coat hook.<br />

Photo #UCR P5281 College Building South-46-1 (originally 0301-400)<br />

69


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

47. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #118 at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform. (56” - 60-1/2”.)<br />

Recommendation:<br />

Relocate electrical control or other switch.<br />

Photo #UCR P5281 College Building South-47-1 (originally 0302-400)<br />

70


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

48. Doors - Office Room #116 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1”.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Photo #UCR P5281 College Building South-48-1 (originally 0303-400)<br />

71


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-48-2 (originally 0304-400)<br />

Photo #UCR P5281 College Building South-48-3 (originally 0305-400)<br />

72


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

49. Clear Space at Doors - Office Room #116 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach.<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-49-1 (originally 0306-400)<br />

73


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-49-2 (originally 0307-400)<br />

74


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

50. Doors - Between Rooms #118 and #100 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-50-1 (originally 0308-400)<br />

75


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-50-2 (originally 0309-400)<br />

76


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

51. Clear Space at Doors - Between Rooms #118 and #100 at Ground<br />

Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (42” to the desk.)<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (13” to the copier.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-51-1 (originally 0310-400)<br />

77


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-51-2 (originally 0311-400)<br />

78


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

52. Doors - Room #114 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1/2” not beveled.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Photo #UCR P5281 College Building South-52-1 (originally 0312-400)<br />

79


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

53. Clear Space at Doors - Room #114 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach.<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-53-1 (originally 0313-400)<br />

80


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

54. Assistive Listening Systems - Room #114 at Ground Level.<br />

Memo:<br />

Not required here.<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-54-1 (originally 0314-400)<br />

81


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

55. Seating, Tables and Work Surfaces - Room #114 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

30” x 48” min. clear floor space is provided.<br />

One full unobstructed side of clear floor space adjoins or overlaps an accessible route or another wheelchair clear floor space.<br />

27” high, 30” wide and 19” deep knee clearance provided.<br />

28” - 34” height of table or work surface that is 36” wide.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-55-1 (originally 0315-400)<br />

82


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

56. Protruding Objects - Room #114 at Ground Level.<br />

Memo:<br />

Fireplace.<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Objects projecting from walls (i.e. telephones, etc.) have 4” maximum projection into walks, halls, corridors, passageways<br />

or aisles if lower edge of object is above 27” and below 80”. (8-1/2”.)<br />

Recommendation:<br />

Install cane detectable barrier below object.<br />

Photo #UCR P5281 College Building South-56-1 (originally 0318-400)<br />

83


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

57. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #114 at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform.<br />

Areas not meeting new construction standards:<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor or<br />

working platform. (6-1/4”.)<br />

Recommendation:<br />

Relocate electrical receptacle.<br />

Photo #UCR P5281 College Building South-57-1 (originally 0319-400)<br />

84


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

58. Doors - Between Rooms #112 and #114 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1/2” not beveled.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Photo #UCR P5281 College Building South-58-1 (originally 0320-400)<br />

85


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-58-2 (originally 0321-400)<br />

Photo #UCR P5281 College Building South-58-3 (originally 0322-400)<br />

86


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

59. Clear Space at Doors - Between Rooms #112 and #114 at Ground<br />

Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach.<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (50-1/2” to the furniture.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-59-1 (originally 0323-400)<br />

87


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-59-2 (originally 0324-400)<br />

88


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

60. Doors - Between Room #112 and Hall Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1”.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Photo #UCR P5281 College Building South-60-1 (originally 0326-400)<br />

89


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-60-2 (originally 0328-400)<br />

Photo #UCR P5281 College Building South-60-3 (originally 0329-400)<br />

90


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

61. Clear Space at Doors - Between Room #112 and Hall Entrance at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach.<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-61-1 (originally 0330-400)<br />

91


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-61-2 (originally 0331-400)<br />

92


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

62. Seating, Tables and Work Surfaces - Room #112 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

One full unobstructed side of clear floor space adjoins or overlaps an accessible route or another wheelchair clear floor space.<br />

28” - 34” height of table or work surface that is 36” wide.<br />

Areas not meeting new construction standards:<br />

30” x 48” min. clear floor space is provided.<br />

27” high, 30” wide and 19” deep knee clearance provided. (26-1/2”.)<br />

Recommendation:<br />

Provide accessible table.<br />

Photo #UCR P5281 College Building South-62-1 (originally 0332-400)<br />

93


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

63. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #112 at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform.<br />

Areas not meeting new construction standards:<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor or<br />

working platform. (6-1/2”.)<br />

Recommendation:<br />

Relocate electrical receptacle.<br />

Photo #UCR P5281 College Building South-63-1 (originally 0333-400)<br />

94


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

64. Doors - Women’s Restroom Left of Room #103 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1/2” not beveled.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Photo #UCR P5281 College Building South-64-1 (originally 0334-400)<br />

95


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-64-2 (originally 0335-400)<br />

Photo #UCR P5281 College Building South-64-3 (originally 0338-400)<br />

96


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

65. Clear Space at Doors - Women’s Restroom Left of Room #103 at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach.<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (36” to the bookcase.)<br />

44” min. clear space opposite direction of door swing (48” with latch and closer). (11” to the furniture.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-65-1 (originally 0339-400)<br />

97


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-65-2 (originally 0340-400)<br />

98


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

66. Identification Symbols, Restrooms - Women’s Restroom Left of Room<br />

#103 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Women’s - 12” diameter circle 1/4” thick. The circle symbol contrasts with the door, light on dark background or dark<br />

on light background. (Incorrect.)<br />

Wall mounted signage: Symbol of accessibility is mounted on wall sign adjacent to latch side of door. (No signage.)<br />

Recommendation:<br />

Install door-mounted sign on single door.<br />

Install wall-mounted sign at single entrance.<br />

Photo #UCR P5281 College Building South-66-1 (originally 0341-400)<br />

99


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

67. Single Accommodation Toilet - Women’s Restroom Left of Room<br />

#103 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Space for 30” x 48” wheelchair to enter and permit door to close.<br />

Privacy lock, push button, lever release.<br />

28” minimum between the side of the water closet and any fixture or a minimum of 32” clear space between the side of<br />

the water closet to opposite wall or partition.<br />

18” between centerline of water closet and side wall or partition.<br />

44” max. height to flush valve.<br />

Flush valve is on wide side of the water closet<br />

5 lb. max. force is required to operate the flush valve.<br />

Front of toilet paper dispenser is within 36” of the back wall.<br />

The toilet paper dispenser is located on the side wall below the grab bar and within 12” of the front of the toilet<br />

seat.<br />

19” min. height to toilet paper dispenser.<br />

Toilet paper dispenser provides continuous flow.<br />

Areas not meeting new construction standards:<br />

60” minimum diameter turning circle, or a T-shaped clear space, is provided in room with 12” maximum door encroachment<br />

into the required clear space. (55-1/2” to furniture.)<br />

42” min. clearance between centerline of water closet and opposite wall. (39-1/4” to the cabinet.)<br />

A minimum 60” wide and 48” deep clear floor space is provided in front of water closet. (55” x 48”.)<br />

The top of the toilet seat is 17” - 19” from the floor surface measured to the top of a maximum 2” high toilet seat<br />

(a 3” high seat shall be permitted only in alterations where the existing fixture is less than 15” high). (19-1/2”.)<br />

Recommendation:<br />

Replace water closet.<br />

Relocate furniture to provide clear space.<br />

100


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-67-1 (originally 0342-400)<br />

101


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

68. Toilet Grab Bars - Women’s Restroom Left of Room #103 at Ground<br />

Level.<br />

Memo:<br />

Areas noted in compliance:<br />

1-1/4” to 1-1/2” diameter of bars.<br />

1-1/2” clearance between bars and each wall or partition.<br />

The side grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor.<br />

(32-1/2” high.)<br />

The rear grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor (for<br />

tank type toilets, 36” may be allowed if tank obstructs placement of bar). (36” high (tank).)<br />

Side bar has 42” min. length.<br />

The front of the side grab bar extends 54” from back wall in single accommodation stall.<br />

Back bar has 36” min. length.<br />

Back bar begins a max. of 6” from side wall.<br />

Bars are smooth with a min. edge radius of 1/8”.<br />

Grab bars do not rotate within their fittings.<br />

Min. structural strength to support 250 lb. point load.<br />

Surface of wall adjacent to grab bars are free of sharp or abrasive elements.<br />

Areas not meeting new construction standards:<br />

Side bar begins a max. of 12” from back wall. (13-3/4”.)<br />

Area directly above grab bars or proposed grab bars is free of protruding obstructions to a height of 18” (recessed<br />

items are allowed). (Toilet paper dispenser - 6”.)<br />

Recommendation:<br />

Relocate grab bar.<br />

Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.<br />

102


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-68-1 (originally 0343-400)<br />

103


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

69. Lavatories - Women’s Restroom Left of Room #103 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

30” x 48” min. clear space provided in front of lavatory that allows forward approach (doors may not encroach into this<br />

space).<br />

Required clear space extends 19” max. underneath the lavatory and adjoins or over laps an accessible route.<br />

18” minimum from center of fixture to side wall or partition.<br />

34” max. height to rim or counter above floor surface.<br />

29” min. clearance from bottom of apron to floor surface.<br />

30” wide x 9” high x 17” deep clearance from front of lavatory.<br />

There are no sharp or abrasive elements under lavatory.<br />

Faucets are lever type, electronically activated or approved self closing valves (10 second open flow).<br />

Faucets are operable with one hand and do not require tight grasping, pinching or twisting of wrist.<br />

5 lb. max. force required to operate controls.<br />

Areas not meeting new construction standards:<br />

27” high x 8” deep knee clearance under front lip. (25-1/2”.)<br />

Drain and piping is insulated or configured to prevent contact. (No insulation.)<br />

Recommendation:<br />

Raise/Lower existing lavatory.<br />

Insulate pipes under lavatory (or sink when applicable).<br />

104


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-69-1 (originally 0344-400)<br />

105


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

70. Accessories - Women’s Restroom Left of Room #103 at Ground<br />

Level.<br />

Memo:<br />

Areas noted in compliance:<br />

40” maximum height to bottom of reflective surface of mirror.<br />

height above floor surface is recom-<br />

Coat hooks and shelving are located within appropriate reach ranges (48” max.<br />

mended).<br />

Accessories do not require tight grasping, pinching or twisting of the wrist to operate.<br />

A minimum 30” x 48” minimum clear floor or ground space is provided to allow forward or parallel approach to accessories.<br />

A maximum of 5 lbs. force is required to operate mechanisms.<br />

Areas not meeting new construction standards:<br />

40” max. height to all other fixtures (i.e., soap dispensers, towels, toilet seat covers, auto dryers, sanitary napkins, waste<br />

recepatacles, etc.). (Paper towel - 42” high.)<br />

Recommendation:<br />

Relocate the paper towel dispenser / hand dryer.<br />

Photo #UCR P5281 College Building South-70-1 (originally 0345-400)<br />

106


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

71. Electrical Controls & Receptacles/Fire Alarm Boxes - Women’s<br />

Restroom Left of Room #103 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform. (53-3/4” (side reach)..)<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor<br />

or working platform.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-71-1 (originally 0346-400)<br />

107


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

72. Stairways - North Stairway.<br />

Memo:<br />

Areas noted in compliance:<br />

44” min. width if occupant load is more than 50.<br />

All treads are slip resistant.<br />

Nosing projection is less than 1-1/2”.<br />

All steps have uniform riser height and tread width. (7-1/4” - 7-1/2” riser / 11-1/4” - 12-1/4” tread.)<br />

11” min. tread width.<br />

Stairs do not accumulate water.<br />

Areas not meeting new construction standards:<br />

All risers are closed. (Nosing protrudes.)<br />

Int. - Top landing and lower tread have color striping minimum 2” wide and a maximum 4” wide parallel to, and<br />

not more than 1” maximum from tread nose or landing. (No striping.)<br />

Recommendation:<br />

Install slip-resistant color contrast striping to steps.<br />

Photo #UCR P5281 College Building South-72-1 (originally 0347-400)<br />

108


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

73. Stairway Handrails - North Stairway.<br />

Memo:<br />

Areas noted in compliance:<br />

1-1/4” to 1-1/2” handgrip portion or cross section equivalent or the shape provides an equivalent gripping surface.<br />

Rails are 34” - 38” above stair nosing.<br />

Handrails do not rotate in their fittings.<br />

Ends of rails are rounded or returned smoothly to wall or floor.<br />

Handrail is smooth with no sharp edges.<br />

Handrails do not protrude into pathways.<br />

Inner rails that double back or turn are continuous.<br />

Areas not meeting new construction standards:<br />

Handrails are provided on both sides and are continuous for the full length of the stairway. (One side.)<br />

12” minimum level extension beyond top nosing (parallel with the ground or floor surface) before being returned. (0”.)<br />

12” plus one tread width level extension beyond bottom nosing (parallel with the ground or floor surface) before being<br />

returned. (0”.)<br />

Recommendation:<br />

Install new wall-mounted handrails.<br />

Install new free-standing handrails.<br />

109


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-73-1 (originally 0348-400)<br />

110


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

74. Stairway Signage - North Stairway.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Identification signage is located at each floor level in all enclosed stairways in buildings two or more stories in height. (No<br />

signage.)<br />

Recommendation:<br />

Install new signage at stairwell.<br />

Photo #UCR P5281 College Building South-74-1 (originally 0349-400)<br />

111


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

75. Water Fountains (Drinking) - At the Hall Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

32” minimum wide and 18” minimum deep alcove provided.<br />

Lever or push bar control is located 6” max. from front edge.<br />

Bubbler outlet is 6” maximum from front.<br />

4” minimum height of stream.<br />

The force required to activate controls does not exceed 5lbf.<br />

Areas not meeting new construction standards:<br />

18” minimum depth of fountain. (15”.)<br />

27” high x 8” deep clear knee space under fountain. (0”.)<br />

9” high x 17” deep toe clearance. (0”.)<br />

Bubbler outlet is 36” maximum from floor. (39-1/2”.)<br />

Stream of bubbler is parallel to front edge. (Not parallel.)<br />

Two fountains are provided, one that is wheelchair accessible and one at normal height for those persons having difficulty<br />

bending or stooping. (No Hi-Lo.)<br />

Recommendation:<br />

Install new HI-LO drinking fountain.<br />

112


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-75-1 (originally 0350-400)<br />

113


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

76. Stairways - North Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

44” min. width if occupant load is more than 50.<br />

All treads are slip resistant.<br />

Nosing projection is less than 1-1/2”.<br />

All steps have uniform riser height and tread width.<br />

Stairs do not accumulate water.<br />

Areas not meeting new construction standards:<br />

All risers are closed. (Nosing protrudes.)<br />

11” min. tread width.<br />

Int. - Top landing and lower tread have color striping minimum 2” wide and a maximum 4” wide parallel to, and<br />

not more than 1” maximum from tread nose or landing. (No striping.)<br />

Recommendation:<br />

Install slip-resistant color contrast striping to steps.<br />

Photo #UCR P5281 College Building South-76-1 (originally 0351-400)<br />

114


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

77. Stairway Handrails - North Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Handrails are provided on both sides and are continuous for the full length of the stairway.<br />

Recommendation:<br />

Install new wall-mounted handrails.<br />

Photo #UCR P5281 College Building South-77-1 (originally 0352-400)<br />

115


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

78. Stairway Signage - North Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-78-1 (originally 0353-400)<br />

116


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

79. Doors - North Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (2-3/4”.)<br />

5 lb. maximum pressure to operate exterior doors. (11 lbs.)<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type). (Knob.)<br />

The international symbol of accessibility is posted at all primary entrances. (No International Symbol of Accessibility.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.<br />

Replace door hardware with compliant hardware.<br />

Post a sign/decal displaying the ”International Symbol of Accessibility” at the primary entrance.<br />

Install level exterior door landing.<br />

117


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-79-1 (originally 0354-400)<br />

Photo #UCR P5281 College Building South-79-2 (originally 0355-400)<br />

118


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-79-3 (originally 0356-400)<br />

119


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

80. Clear Space at Doors - North Entrance at Ground Level.<br />

Memo:<br />

See Sequence #79 for additional recommendations.<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (45” to the step.)<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (11-1/2” to the wall.)<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer. (0” to the wall.)<br />

Recommendation:<br />

Remove door latch and/or door closer.<br />

Photo #UCR P5281 College Building South-80-1 (originally 0357-400)<br />

120


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-80-2 (originally 0358-400)<br />

121


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

81. Stairways - Exterior North Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

44” min. width if occupant load is more than 50.<br />

All treads are slip resistant.<br />

Nosing projection is less than 1-1/2”.<br />

All risers are closed.<br />

11” min. tread width.<br />

Stairs do not accumulate water.<br />

Areas not meeting new construction standards:<br />

All steps have uniform riser height and tread width. (12-1/2” - 30” tread.)<br />

Ext. - Top landing and all steps have color striping minimum 2” wide and a maximum 4” wide parallel to, and not<br />

more than 1” maximum from tread nose or landing. (No striping.)<br />

Recommendation:<br />

Install slip-resistant color contrast striping to steps.<br />

Photo #UCR P5281 College Building South-81-1 (originally 0359-400)<br />

122


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

82. Stairway Handrails - Exterior North Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

1-1/4” to 1-1/2” handgrip portion or cross section equivalent or the shape provides an equivalent gripping surface.<br />

12” minimum level extension beyond top nosing (parallel with the ground or floor surface) before being returned.<br />

Handrails do not rotate in their fittings.<br />

Ends of rails are rounded or returned smoothly to wall or floor.<br />

Handrail is smooth with no sharp edges.<br />

Handrails do not protrude into pathways.<br />

Inner rails that double back or turn are continuous.<br />

Areas not meeting new construction standards:<br />

Handrails are provided on both sides and are continuous for the full length of the stairway. (One side only.)<br />

Rails are 34” - 38” above stair nosing. (42” high.)<br />

12” plus one tread width level extension beyond bottom nosing (parallel with the ground or floor surface) before being<br />

returned. (0”.)<br />

Recommendation:<br />

Install new wall-mounted handrails.<br />

Install new free-standing handrails.<br />

123


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-82-1 (originally 0360-400)<br />

124


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

83. Doors - Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Areas not meeting new construction standards:<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be opened<br />

by a wheelchair footrest without creating a trap or hazardous condition (kick plate). (Door stop.)<br />

Recommendation:<br />

Remove door stop.<br />

Photo #UCR P5281 College Building South-83-1 (originally 0361)<br />

125


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-83-2 (originally 0363-400)<br />

126


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

84. Clear Space at Doors - Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Floor or landing is level and clear (2% max. slope). (7.7%.)<br />

60” min. clear space in direction of door swing. (52” to the table.)<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (17-1/2” to shelving.)<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer. (4” to the wall.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Relocate furniture to provide clear space.<br />

Remove door latch and/or door closer.<br />

Photo #UCR P5281 College Building South-84-1 (originally 0364-400)<br />

127


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-84-2 (originally 0365-400)<br />

128


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

85. Controls, Operating Mechanisms & Vending Machines. - Room #104<br />

at Ground Level.<br />

Memo:<br />

Copy machine.<br />

Areas noted in compliance:<br />

Controls and operating mechanisms (handles, coin slots, openings, buttons, etc.) are operable with one hand and do not<br />

require tight grasping, pinching or twisting of the wrist to operate.<br />

Forward Reach to Objects: Minimum 30” x 48” clear floor space for forward approach is provided at object.<br />

Forward Reach to Objects: Highest operable part of object is a maximum of 48” above the floor surface.<br />

Forward Reach to Objects: Lowest operable part of object is a minimum of 15” above the floor surface.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-85-1 (originally 0366-400)<br />

129


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

86. Aisles - Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

36” minimum width of aisles. (28-1/2”.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-86-1 (originally 0367-400)<br />

130


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

87. Electrical Controls & Receptacles/Fire Alarm Boxes - Room #104 at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform.<br />

Areas not meeting new construction standards:<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor or<br />

working platform. (10”.)<br />

Recommendation:<br />

Relocate electrical receptacle.<br />

Photo #UCR P5281 College Building South-87-1 (originally 0368-400)<br />

131


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-87-2 (originally 0369-400)<br />

132


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

88. Doors - Room #104 at Ground Level.<br />

Memo:<br />

Two doors.<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-88-1 (originally 0370-400)<br />

133


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-88-2 (originally 0371-400)<br />

134


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

89. Clear Space at Doors - Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (Varies.)<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (Varies.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-89-1 (originally 0372-400)<br />

135


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-89-2 (originally 0373-400)<br />

136


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

90. Signage - Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Signage for Permanent Rooms and Spaces: Letters are 1/32” raised, uppercase or sans serif w/ Grade II Braille.<br />

Raised characters are 5/8” to 2” high.<br />

Braille dots are 1/10” on center in each cell with 2/10” space between cells.<br />

Braille dots are raised a minimum 1/40” above the background.<br />

Permanent I.D. signs, when provided, are installed on the wall adjacent to the latch side of the door NOTE: At double<br />

leaf doors, and when there is no room on the latch side, signs shall be placed on the nearest adjacent wall, preferably<br />

on the right.<br />

Mounting location allows a person to approach within 3” of the signage without encountering protruding objects or<br />

standing w/in the swing of a door.<br />

Characters and background of sign(s) is eggshell, matte or other non-glare finish.<br />

Characters contrast with their background (light characters on a dark background, or dark characters on a light background).<br />

Areas not meeting new construction standards:<br />

Mounting height is 60” from the finish floor to the centerline of the sign. (58”.)<br />

Recommendation:<br />

Relocate existing signage.<br />

137


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-90-1 (originally 0374-400)<br />

Photo #UCR P5281 College Building South-90-2 (originally 0375-400)<br />

138


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

91. Doors - Men’s Restroom in Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1/2” threshold.)<br />

32” minimum clear width of doorway. (30”.)<br />

5 lb. maximum pressure to operate interior doors. (12 lbs.)<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch. (2 seconds.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.<br />

Replace door(s) and frame (stud wall).<br />

Photo #UCR P5281 College Building South-91-1 (originally 0376-400)<br />

139


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-91-2 (originally 0377-400)<br />

Photo #UCR P5281 College Building South-91-3 (originally 0378-400)<br />

140


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

92. Clear Space at Doors - Men’s Restroom in Room #104 at Ground<br />

Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (36” to boxes.)<br />

(11-1/2” to trash recepta-<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach.<br />

cle.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Relocate existing trash receptacle to provide required clearance.<br />

Photo #UCR P5281 College Building South-92-1 (originally 0379-400)<br />

141


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-92-2 (originally 0380-400)<br />

142


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

93. Identification Symbols, Restrooms - Men’s Restroom in Room #104<br />

at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Door mounted signage: Men’s - Equilateral triangle with 12” sides, 1/4” thick with the vertex pointing up. The triangle<br />

symbol contrasts with the door, light on dark background or dark on light background.<br />

Signs are centered on door 60” from floor.<br />

Areas not meeting new construction standards:<br />

Wall mounted signage: Symbol of accessibility is mounted on wall sign adjacent to latch side of door. (No signage.)<br />

Recommendation:<br />

Install wall-mounted sign at single entrance.<br />

Photo #UCR P5281 College Building South-93-1 (originally 0381-400)<br />

143


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

94. Single Accommodation Toilet - Men’s Restroom in Room #104 at<br />

Ground Level.<br />

Memo:<br />

Used as storage. Provide clear space by relocating all storage.<br />

Areas noted in compliance:<br />

Space for 30” x 48” wheelchair to enter and permit door to close.<br />

Privacy lock, push button, lever release.<br />

28” minimum between the side of the water closet and any fixture or a minimum of 32” clear space between the side of<br />

the water closet to opposite wall or partition.<br />

18” between centerline of water closet and side wall or partition.<br />

42” min. clearance between centerline of water closet and opposite wall.<br />

44” max. height to flush valve.<br />

Flush valve is on wide side of the water closet<br />

5 lb. max. force is required to operate the flush valve.<br />

Front of toilet paper dispenser is within 36” of the back wall.<br />

The toilet paper dispenser is located on the side wall below the grab bar and within 12” of the front of the toilet<br />

seat.<br />

19” min. height to toilet paper dispenser.<br />

Toilet paper dispenser provides continuous flow.<br />

Areas not meeting new construction standards:<br />

60” minimum diameter turning circle, or a T-shaped clear space, is provided in room with 12” maximum door encroachment<br />

into the required clear space. (30”.)<br />

A minimum 60” wide and 48” deep clear floor space is provided in front of water closet. (60” x 23”.)<br />

The top of the toilet seat is 17” - 19” from the floor surface measured to the top of a maximum 2” high toilet seat<br />

(a 3” high seat shall be permitted only in alterations where the existing fixture is less than 15” high). (16”.)<br />

Recommendation:<br />

Provide a toilet seat to comply with the maximum height requirement of 17” - 19”.<br />

Move boxes, carts, non-fixed trash receptacles, etc. to provide required minimum door swing and/or clear space.<br />

144


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-94-1 (originally 0382-400)<br />

145


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

95. Toilet Grab Bars - Men’s Restroom in Room #104 at Ground Level.<br />

Memo:<br />

Two grab bars.<br />

Areas noted in compliance:<br />

1-1/4” to 1-1/2” diameter of bars.<br />

1-1/2” clearance between bars and each wall or partition.<br />

The side grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor.<br />

(33-1/4” high.)<br />

The rear grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor (for<br />

tank type toilets, 36” may be allowed if tank obstructs placement of bar). (33-1/4” high.)<br />

Side bar has 42” min. length.<br />

The front of the side grab bar extends 54” from back wall in single accommodation stall.<br />

Side bar begins a max. of 12” from back wall.<br />

Back bar has 36” min. length.<br />

Back bar begins a max. of 6” from side wall.<br />

Bars are smooth with a min. edge radius of 1/8”.<br />

Grab bars do not rotate within their fittings.<br />

Min. structural strength to support 250 lb. point load.<br />

Surface of wall adjacent to grab bars are free of sharp or abrasive elements.<br />

Areas not meeting new construction standards:<br />

Area directly above grab bars or proposed grab bars is free of protruding obstructions to a height of 18” (recessed items<br />

are allowed). (Toilet paper dispenser - 15-1/4” / seat cover dispenser.)<br />

Recommendation:<br />

Relocate the seat cover dispenser away from the top of the grab bars or proposed grab bars.<br />

Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.<br />

146


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-95-1 (originally 0383-400)<br />

147


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

96. Lavatories - Men’s Restroom in Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

30” x 48” min. clear space provided in front of lavatory that allows forward approach (doors may not encroach into this<br />

space).<br />

Required clear space extends 19” max. underneath the lavatory and adjoins or over laps an accessible route.<br />

18” minimum from center of fixture to side wall or partition.<br />

34” max. height to rim or counter above floor surface.<br />

29” min. clearance from bottom of apron to floor surface.<br />

30” wide x 9” high x 17” deep clearance from front of lavatory.<br />

There are no sharp or abrasive elements under lavatory.<br />

Faucets are lever type, electronically activated or approved self closing valves (10 second open flow).<br />

Faucets are operable with one hand and do not require tight grasping, pinching or twisting of wrist.<br />

5 lb. max. force required to operate controls.<br />

Areas not meeting new construction standards:<br />

27” high x 8” deep knee clearance under front lip. (25” high.)<br />

Drain and piping is insulated or configured to prevent contact. (No insulation.)<br />

Recommendation:<br />

Raise/Lower existing lavatory.<br />

Insulate pipes under lavatory (or sink when applicable).<br />

148


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-96-1 (originally 0384-400)<br />

149


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

97. Accessories - Men’s Restroom in Room #104 at Ground Level.<br />

Memo:<br />

See Sequence #95 for additional recommendations.<br />

Areas noted in compliance:<br />

Coat hooks and shelving are located within appropriate reach ranges (48” max. height above floor surface is recommended).<br />

Accessories do not require tight grasping, pinching or twisting of the wrist to operate.<br />

A minimum 30” x 48” minimum clear floor or ground space is provided to allow forward or parallel approach to accessories.<br />

A maximum of 5 lbs. force is required to operate mechanisms.<br />

Areas not meeting new construction standards:<br />

40” maximum height to bottom of reflective surface of mirror. (40-1/4”.)<br />

40” max. height to all other fixtures (i.e., soap dispensers, towels, toilet seat covers, auto dryers, sanitary napkins,<br />

waste recepatacles, etc.). (Toilet paper dispenser - 49-1/2” / paper towel dispenser - 58” / seat cover dispenser - 60”.)<br />

Recommendation:<br />

Relocate mirror.<br />

Relocate the paper towel dispenser / hand dryer.<br />

Photo #UCR P5281 College Building South-97-1 (originally 0385-400)<br />

150


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-97-2 (originally 0387-400)<br />

151


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

98. Electrical Controls & Receptacles/Fire Alarm Boxes - Men’s Restroom<br />

in Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform.<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor<br />

or working platform.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-98-1 (originally 0388-400)<br />

152


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-98-2 (originally 0390-400)<br />

153


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

99. Doors - Women’s Restroom in Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1/2” not beveled.)<br />

5 lb. maximum pressure to operate interior doors. (10 lbs.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.<br />

Photo #UCR P5281 College Building South-99-1 (originally 0391-400)<br />

154


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-99-2 (originally 0392-400)<br />

Photo #UCR P5281 College Building South-99-3 (originally 0394-400)<br />

155


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

100. Clear Space at Doors - Women’s Restroom in Room #104 at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach.<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (36” to furniture.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-100-1 (originally 0395-400)<br />

156


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-100-2 (originally 0396-400)<br />

157


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

101. Identification Symbols, Restrooms - Women’s Restroom in Room<br />

#104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Women’s - 12” diameter circle 1/4” thick. The circle symbol contrasts with the door, light on dark background or dark<br />

on light background.<br />

Signs are centered on door 60” from floor.<br />

Areas not meeting new construction standards:<br />

Wall mounted signage: Symbol of accessibility is mounted on wall sign adjacent to latch side of door. (No signage.)<br />

Recommendation:<br />

Install wall-mounted sign at single entrance.<br />

Photo #UCR P5281 College Building South-101-1 (originally 0397-400)<br />

158


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

102. Single Accommodation Toilet - Women’s Restroom in Room #104<br />

at Ground Level.<br />

Memo:<br />

See Sequence #100 for additional recommendations.<br />

Areas noted in compliance:<br />

Space for 30” x 48” wheelchair to enter and permit door to close.<br />

Privacy lock, push button, lever release.<br />

28” minimum between the side of the water closet and any fixture or a minimum of 32” clear space between the side of<br />

the water closet to opposite wall or partition.<br />

18” between centerline of water closet and side wall or partition. (18-1/4” (within dimensional tolerance).)<br />

42” min. clearance between centerline of water closet and opposite wall.<br />

44” max. height to flush valve.<br />

Flush valve is on wide side of the water closet<br />

5 lb. max. force is required to operate the flush valve.<br />

Front of toilet paper dispenser is within 36” of the back wall.<br />

The toilet paper dispenser is located on the side wall below the grab bar and within 12” of the front of the toilet<br />

seat.<br />

19” min. height to toilet paper dispenser.<br />

Toilet paper dispenser provides continuous flow.<br />

Areas not meeting new construction standards:<br />

60” minimum diameter turning circle, or a T-shaped clear space, is provided in room with 12” maximum door encroachment<br />

into the required clear space. (45” to furniture.)<br />

A minimum 60” wide and 48” deep clear floor space is provided in front of water closet. (60” x 36” to furniture.)<br />

The top of the toilet seat is 17” - 19” from the floor surface measured to the top of a maximum 2” high toilet seat<br />

(a 3” high seat shall be permitted only in alterations where the existing fixture is less than 15” high). (16” high.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Provide a toilet seat to comply with the maximum height requirement of 17” - 19”.<br />

159


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-102-1 (originally 0398-400)<br />

160


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

103. Toilet Grab Bars - Women’s Restroom in Room #104 at Ground<br />

Level.<br />

Memo:<br />

Two bars.<br />

Areas noted in compliance:<br />

1-1/4” to 1-1/2” diameter of bars.<br />

1-1/2” clearance between bars and each wall or partition.<br />

The side grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor.<br />

(33-1/2”.)<br />

The rear grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor (for<br />

tank type toilets, 36” may be allowed if tank obstructs placement of bar). (33-1/2”.)<br />

Side bar has 42” min. length.<br />

The front of the side grab bar extends 54” from back wall in single accommodation stall.<br />

Side bar begins a max. of 12” from back wall.<br />

Back bar has 36” min. length.<br />

Back bar begins a max. of 6” from side wall.<br />

Bars are smooth with a min. edge radius of 1/8”.<br />

Grab bars do not rotate within their fittings.<br />

Min. structural strength to support 250 lb. point load.<br />

Surface of wall adjacent to grab bars are free of sharp or abrasive elements.<br />

Areas not meeting new construction standards:<br />

Area directly above grab bars or proposed grab bars is free of protruding obstructions to a height of 18” (recessed items<br />

are allowed). (Toilet paper dispenser - 15-1/2” / seat cover dispenser.)<br />

Recommendation:<br />

Relocate the seat cover dispenser away from the top of the grab bars or proposed grab bars.<br />

Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.<br />

161


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-103-1 (originally 0399-400)<br />

162


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

104. Lavatories - Women’s Restroom in Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

30” x 48” min. clear space provided in front of lavatory that allows forward approach (doors may not encroach into this<br />

space).<br />

Required clear space extends 19” max. underneath the lavatory and adjoins or over laps an accessible route.<br />

18” minimum from center of fixture to side wall or partition.<br />

34” max. height to rim or counter above floor surface.<br />

29” min. clearance from bottom of apron to floor surface.<br />

30” wide x 9” high x 17” deep clearance from front of lavatory.<br />

Drain and piping is insulated or configured to prevent contact.<br />

There are no sharp or abrasive elements under lavatory.<br />

Faucets are lever type, electronically activated or approved self closing valves (10 second open flow).<br />

Faucets are operable with one hand and do not require tight grasping, pinching or twisting of wrist.<br />

5 lb. max. force required to operate controls.<br />

Areas not meeting new construction standards:<br />

27” high x 8” deep knee clearance under front lip. (25” high.)<br />

Recommendation:<br />

Raise/Lower existing lavatory.<br />

163


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-104-1 (originally 0400-400)<br />

164


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

105. Accessories - Women’s Restroom in Room #104 at Ground Level.<br />

Memo:<br />

See Sequence #103 for additional recommendations.<br />

Areas noted in compliance:<br />

40” max. height to all other fixtures (i.e., soap dispensers, towels, toilet seat covers, auto dryers, sanitary napkins, waste<br />

recepatacles, etc.). (Toilet paper dispenser - 49” / paper towel dispenser - 57-1/2” / seat cover dispenser - 60”.)<br />

height above floor surface is recom-<br />

Coat hooks and shelving are located within appropriate reach ranges (48” max.<br />

mended).<br />

Accessories do not require tight grasping, pinching or twisting of the wrist to operate.<br />

A minimum 30” x 48” minimum clear floor or ground space is provided to allow forward or parallel approach to accessories.<br />

A maximum of 5 lbs. force is required to operate mechanisms.<br />

Areas not meeting new construction standards:<br />

40” maximum height to bottom of reflective surface of mirror. (40-1/2”.)<br />

Recommendation:<br />

Relocate mirror.<br />

Relocate the seat cover dispenser.<br />

Relocate the paper towel dispenser / hand dryer.<br />

Relocate the toilet paper dispenser.<br />

Photo #UCR P5281 College Building South-105-1 (originally 0401-400)<br />

165


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-105-2 (originally 0402-400)<br />

166


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

106. Electrical Controls & Receptacles/Fire Alarm Boxes - Women’s<br />

Restroom in Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform.<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor<br />

or working platform.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-106-1 (originally 0403-400)<br />

167


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-106-2 (originally 0404-400)<br />

168


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

107. Doors - Southwest Exit Door Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

5 lb. maximum pressure to operate exterior doors. (26 lbs.)<br />

Recommendation:<br />

Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.<br />

Photo #UCR P5281 College Building South-107-1 (originally 0405-400)<br />

169


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-107-2 (originally 0406-400)<br />

170


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

108. Clear Space at Doors - Southwest Exit Door Room #104 at Ground<br />

Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 24” exterior doors.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (49” to curb.)<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer. (4” to the wall partition.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Remove door latch and/or door closer.<br />

Photo #UCR P5281 College Building South-108-1 (originally 0407-400)<br />

171


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-108-2 (originally 0408-400)<br />

172


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

109. Stairways - Outside of the South Exit Door in Room #104 at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

36” min. width if occupant load is less than 50.<br />

All treads are slip resistant.<br />

Nosing projection is less than 1-1/2”.<br />

All risers are closed.<br />

All steps have uniform riser height and tread width.<br />

11” min. tread width.<br />

Stairs do not accumulate water.<br />

Areas not meeting new construction standards:<br />

Ext. - Top landing and all steps have color striping minimum 2” wide and a maximum 4” wide parallel to, and not more<br />

than 1” maximum from tread nose or landing. (No striping.)<br />

Recommendation:<br />

Install slip-resistant color contrast striping to steps.<br />

Photo #UCR P5281 College Building South-109-1 (originally 0409-400)<br />

173


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

110. Stairway Handrails - Outside of the South Exit Door in Room #104<br />

at Ground Level.<br />

Memo:<br />

Not required at one riser.<br />

Areas noted in compliance:<br />

Handrails are provided on both sides and are continuous for the full length of the stairway.<br />

1-1/2” clearance provided between rail and wall.<br />

Rails are 34” - 38” above stair nosing.<br />

12” minimum level extension beyond top nosing (parallel with the ground or floor surface) before being returned.<br />

12” plus one tread width level extension beyond bottom nosing (parallel with the ground or floor surface) before being<br />

returned.<br />

Handrails do not rotate in their fittings.<br />

Wall or adjacent surface is free of sharp or abrasive elements.<br />

Ends of rails are rounded or returned smoothly to wall or floor.<br />

Handrail is smooth with no sharp edges.<br />

Handrails do not protrude into pathways.<br />

Areas not meeting new construction standards:<br />

1-1/4” to 1-1/2” handgrip portion or cross section equivalent or the shape provides an equivalent gripping surface. (2-1/2”<br />

(see memo).)<br />

Recommendation:<br />

None.<br />

174


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-110-1 (originally 0410-400)<br />

175


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

111. Tactile Exit Signage - Ground Level of College Building South.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Each grade-level exterior exit door shall be identified by a tactile sign with the word ”EXIT”. (No signage.)<br />

Recommendation:<br />

Provide compliant sign.<br />

Photo #UCR P5281 College Building South-111-1 (originally 0411-400)<br />

176


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-111-2 (originally 0413-400)<br />

177


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

112. Doors - North Exit Door in Room #104 at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

5 lb. maximum pressure to operate exterior doors. (6 lbs.)<br />

Recommendation:<br />

Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.<br />

Photo #UCR P5281 College Building South-112-1 (originally 0413-400)<br />

178


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-112-2 (originally 0414-400)<br />

179


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

113. Clear Space at Doors - North Exit Door in Room #104 at Ground<br />

Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 24” exterior doors.<br />

Areas not meeting new construction standards:<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer. (12” wide x 30” deep.)<br />

Recommendation:<br />

Remove door latch and/or door closer.<br />

Photo #UCR P5281 College Building South-113-1 (originally 0415-400)<br />

180


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-113-2 (originally 0416-400)<br />

181


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

114. Elevators - College Building South.<br />

Memo:<br />

Areas noted in compliance:<br />

Located near major path of travel and are accessible at all times the building is occupied.<br />

68” min. width of the car platform with off-center door panels.<br />

54” min. depth of the car platform (rear wall to door)<br />

51” min. clearance from the rear wall to return panel.<br />

36” min. clear width of doorway when fully open.<br />

Handrail is provided (1 minimum) on one wall of the car (rear preferred).<br />

Operation of doors (opening and closing) is automatic.<br />

Elevator is self leveling within 1/2” of floor landings.<br />

Emergency communication device does not require voice communication.<br />

The car inside allows for the turning of a wheelchair (enter the car, maneuver within reach of controls, and exit from the car).<br />

32” (+or- 1”) height of the handrail from the floor.<br />

Minimum of 1-1/2” clearance of the handrail from the wall.<br />

Handrail is smooth, no sharp edges.<br />

Doors are side-slide type (power-operated horizontally sliding).<br />

The clearance between the car platform sill and the edge of the hoistway landing is no greater than 1-1/4”.<br />

Elevator doors have an automatic reopening device. The device opens the doors when objects pass through the opening<br />

at heights of 5” and 29” from the floor without requiring contact. Doors remain open for 20 seconds minimum.<br />

Doors remain fully open a minimum of 5 seconds when initially activated.<br />

Door jambs at all landings identify the floor by both raised Arabic numerals (minimum of 2” in height) and Braille<br />

symbols (immediately to left of numerals).<br />

Raised characters are on a contrasting background.<br />

Doorjamb markings are centered at 60” above the floor on both sides of the door.<br />

At grade level, a raised five-pointed star with an outside diameter of 2” is placed to the left of the raised character.<br />

Emergency communication device is a maximum of 48” from the floor.<br />

The level of illumination at the platform, car threshold and landing sill is at least 5 foot-candles.<br />

182


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-114-1 (originally 0417-400)<br />

Photo #UCR P5281 College Building South-114-2 (originally 0418-400)<br />

183


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

115. Elevator Control (Panel & Hall Call) - College Building South.<br />

Memo:<br />

Both floors.<br />

Areas noted in compliance:<br />

Elevator car controls are located on a front wall in cars that have center opening doors, and at the side wall or at the front<br />

wall next to the door if the car has side opening doors.<br />

Elevator floor buttons comply with reach range requirements (48” front reach; 54” side reach to centerline of buttons).<br />

Control buttons are square shouldered, and are a minimum of 3/4” and raised 1/8” plus of minus 1/32” above the<br />

sorrounding surface.<br />

Control buttons are illuminated and are activated by a mechanical motion that is detectable.<br />

All buttons are designated by a 5/8” minimum Arabic Numeral, alphabet or other standard sans serif uppercase character,<br />

or standard raised symbol immediately to the left of the control button.<br />

All raised characters are white on a black background.<br />

Grade 2 Braille symbols are located immediately below the raised characters.<br />

3/8” minimum distance between the rows of the control buttons.<br />

Emergency controls (stop and alarm) are a minimum of 35” from the floor.<br />

Hall call buttons are a minimum of 3/4” in size and raised 1/8” plus or minus 1/32” above the sorrounding surface.<br />

Hall call button provides visual indication that shows each call registered and extinguishes when answered.<br />

Objects adjacent to and below hall call buttons do not project more than 4”.<br />

Hall call buttons are internally illuminated with a white light over the entire surface of the button.<br />

Areas not meeting new construction standards:<br />

The centerline of hall call buttons in elevator lobbies are located at 42” above the floor. (40”.)<br />

Recommendation:<br />

None.<br />

184


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-115-1 (originally 0419-400)<br />

Photo #UCR P5281 College Building South-115-2 (originally 0420-400)<br />

185


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

116. Visual and Audible Signals For Elevators - College Building South.<br />

Memo:<br />

Areas noted in compliance:<br />

Elevator has visual and audible signals indicating the position of the car on or between floors. The indication is positioned<br />

above the car control panel or over the door.<br />

The visual signal for each direction is a minimum of 2-1/2” x 2-1/2”, and visible from the proximity of the hall call<br />

button. NOTE: An automatic verbal announcement of the floor number at which a car stops or which a car passes may<br />

be substituted for the audible signal.<br />

Audible signal sounds are once for up and twice for down. (or equivalent)<br />

Audible signal is no less than 20 decibels with a frequency no higher than 1500 Hz.<br />

Centerline of the fixture is a minimum of 6’ (72”) in height above the lobby floor. NOTE: The use of in-car lanterns,<br />

located in or on the door jambs, visible from the proximity of the call buttons and conforming to items 1, 2, & 3 above<br />

shall or will be acceptable.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-116-1 (originally 0421-400)<br />

186


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

117. Pedestrian Ramps - At the North Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

8.33% maximum surface slope at ramp.<br />

2% maximum cross slope at ramp.<br />

48” minimum width required at ramp.<br />

60” x 60” min. top landing. NOTE: When a ramp leads directly to a door that swings out into the top landing<br />

area the top landing must measure a minimum 42”+ the door width.<br />

2% maximum slope in any direction at top landing.<br />

72” minimum bottom landing in the ramp direction.<br />

2% maximum slope in any direction at bottom landing.<br />

Bottom landing is as wide as ramp.<br />

Finished surface is slip resistant.<br />

Handrails are provided on both sides.<br />

Outdoor ramps are designed so water does not accumulate on walking surfaces.<br />

Areas not meeting new construction standards:<br />

Ramps do not exceed allowable lengths. (40’ up to 6.25%, 37.5’ up to 6.67%, 30’ up to 8.33%). (8.6%.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

187


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-117-1 (originally 0422-400)<br />

188


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

118. Ramp Handrails - At the North Entrance at Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Handrails are on both sides and continuous the full length of the ramp.<br />

1-1/4” to 1-1/2” grip portion diameter or cross section equivalent. (1-3/4”.)<br />

Handrail has smooth surface with no sharp edges.<br />

250 lb. point load capacity.<br />

Handrails do not rotate in their fittings.<br />

Non-abrasive wall or surface adjacent to handrail.<br />

Ends of rails are rounded or returned smoothly to floor or wall.<br />

Ramps and landings with drop offs have edge protection consisting of either a guide curb a minimum 2” in height<br />

on each side of the ramp, or a wheel guide rail centered 3” + or - 1” on each side of the ramp.<br />

Areas not meeting new construction standards:<br />

1-1/2” between wall and handrail(s) (2-1/4”.)<br />

34” - 38” finish height above ramp surface to top of handrails. (38” - 40”.)<br />

12” minimum level extension beyond top and bottom of ramp, parallel to the floor or ground surface. The extensions<br />

extend the minimum 12” required distance (parallel to the floor or ground surface) before they are returned. (7-1/2”.)<br />

Recommendation:<br />

Install/Replace free-standing handrails.<br />

189


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-118-1 (originally 0423-400)<br />

190


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

119. Stairways - Northwest Stairwell.<br />

Memo:<br />

Areas noted in compliance:<br />

44” min. width if occupant load is more than 50.<br />

All treads are slip resistant.<br />

Nosing projection is less than 1-1/2”.<br />

All risers are closed.<br />

All steps have uniform riser height and tread width.<br />

11” min. tread width.<br />

Stairs do not accumulate water.<br />

Areas not meeting new construction standards:<br />

Int. - Top landing and lower tread have color striping minimum 2” wide and a maximum 4” wide parallel to, and not more<br />

than 1” maximum from tread nose or landing. (No striping.)<br />

Recommendation:<br />

Install color contrast striping to carpet steps.<br />

Photo #UCR P5281 College Building South-119-1 (originally 0424-400)<br />

191


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

120. Stairway Handrails - Northwest Stairwell.<br />

Memo:<br />

Areas noted in compliance:<br />

Handrails are provided on both sides and are continuous for the full length of the stairway.<br />

1-1/2” clearance provided between rail and wall.<br />

12” plus one tread width level extension beyond bottom nosing (parallel with the ground or floor surface) before being<br />

returned.<br />

Handrails do not rotate in their fittings.<br />

Wall or adjacent surface is free of sharp or abrasive elements.<br />

Ends of rails are rounded or returned smoothly to wall or floor.<br />

Handrail is smooth with no sharp edges.<br />

Handrails do not protrude into pathways.<br />

Areas not meeting new construction standards:<br />

1-1/4” to 1-1/2” handgrip portion or cross section equivalent or the shape provides an equivalent gripping surface. (2”.)<br />

Rails are 34” - 38” above stair nosing. (33” high.)<br />

12” minimum level extension beyond top nosing (parallel with the ground or floor surface) before being returned. (11-3/4”.)<br />

Recommendation:<br />

Raise/Lower existing handrail height.<br />

192


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-120-1 (originally 0424-400)<br />

193


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

121. Stairway Signage - Northwest Stairwell.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Identification signage is located at each floor level in all enclosed stairways in buildings two or more stories in height. (No<br />

signage.)<br />

Recommendation:<br />

Install new signage at stairwell.<br />

Photo #UCR P5281 College Building South-121-1 (originally 0426-400)<br />

194


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

122. Corridors - 2nd Floor of College Building South.<br />

Memo:<br />

Areas noted in compliance:<br />

44” wide intervening T intersection.<br />

Areas not meeting new construction standards:<br />

44” minimum width for occupant loads of 10 or more. (42”.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-122-1 (originally 0427-400)<br />

195


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-122-2 (originally 0431-400)<br />

Photo #UCR P5281 College Building South-122-3 (originally 0432-400)<br />

196


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

123. Aisles - 2nd Floor Corridor.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

36” minimum width of aisles. (28” - 35”.)<br />

Recommendation:<br />

Clear aisle width(s) to comply with minimum required aisle width(s) listed above.<br />

Photo #UCR P5281 College Building South-123-1 (originally 0433-400)<br />

197


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-123-2 (originally 0434-400)<br />

Photo #UCR P5281 College Building South-123-3 (originally 0436-400)<br />

198


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

124. Visual/Audible Alarms - 2nd Floor Corridor.<br />

Memo:<br />

See Sequence #14 for recommendation.<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

The alarm is integrated into the building or facility alarm system. (No system.)<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-124-1 (originally 0437-400)<br />

199


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

125. Electrical Controls & Receptacles/Fire Alarm Boxes - 2nd Floor<br />

Corridor.<br />

Memo:<br />

Areas noted in compliance:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform.<br />

Areas not meeting new construction standards:<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor or<br />

working platform. (9-1/2”.)<br />

Recommendation:<br />

Relocate electrical receptacle.<br />

Photo #UCR P5281 College Building South-125-1 (originally 0438-400)<br />

200


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-125-2 (originally 0439-400)<br />

201


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

126. Tactile Exit Signage - 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Each exit door that leads directly to a grade-level exterior exit by means of a stairway or ramp is identified by a tactile<br />

exit sign that states ”EXIT STAIR DOWN”, ”EXIT RAMP DOWN”, ”EXIT STAIR UP”, or ”EXIT RAMP UP”, as<br />

appropriate. (No signage.)<br />

Recommendation:<br />

Provide compliant sign.<br />

Photo #UCR P5281 College Building South-126-1 (originally 0440-400)<br />

202


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

127. Doors - North Exit Door on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

5 lb. maximum pressure to operate exterior doors. (6 lbs.)<br />

Recommendation:<br />

Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.<br />

Photo #UCR P5281 College Building South-127-1 (originally 0442-400)<br />

203


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-127-2 (originally 0443-400)<br />

204


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

128. Clear Space at Doors - North Exit Door on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 24” exterior doors.<br />

Areas not meeting new construction standards:<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer. (4-1/2”.)<br />

Recommendation:<br />

Remove door latch and/or door closer.<br />

Photo #UCR P5281 College Building South-128-1 (originally 0444-400)<br />

205


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-128-2 (originally 0445-400)<br />

206


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

129. Signage - Throughout the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

Permanent I.D. signs, when provided, are installed on the wall adjacent to the latch side of the door NOTE: At double<br />

leaf doors, and when there is no room on the latch side, signs shall be placed on the nearest adjacent wall, preferably on<br />

the right. (No sign.)<br />

Recommendation:<br />

Install permanent ID sign to latch side of door.<br />

Photo #UCR P5281 College Building South-129-1 (originally 0446-400)<br />

207


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

130. Doors - Rooms #206, #208, #205, #201, #202 and #203 on the<br />

2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-130-1 (originally 0447-400)<br />

208


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-130-2 (originally 0448-400)<br />

209


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

131. Clear Space at Doors - Rooms #206, #208, #205, #201, #202 and<br />

#203 on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (45” to the cabinet in room #202.)<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (Varies - 6” to furniture in<br />

room #202.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-131-1 (originally 0450-400)<br />

210


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-131-2 (originally 0451-400)<br />

211


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

132. Signage - All Doors on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Signage for Permanent Rooms and Spaces: Letters are 1/32” raised, uppercase or sans serif w/ Grade II Braille.<br />

Raised characters are 5/8” to 2” high.<br />

Braille dots are 1/10” on center in each cell with 2/10” space between cells.<br />

Braille dots are raised a minimum 1/40” above the background.<br />

Permanent I.D. signs, when provided, are installed on the wall adjacent to the latch side of the door NOTE: At double<br />

leaf doors, and when there is no room on the latch side, signs shall be placed on the nearest adjacent wall, preferably<br />

on the right.<br />

Mounting location allows a person to approach within 3” of the signage without encountering protruding objects or<br />

standing w/in the swing of a door.<br />

Characters and background of sign(s) is eggshell, matte or other non-glare finish.<br />

Characters contrast with their background (light characters on a dark background, or dark characters on a light background).<br />

Areas not meeting new construction standards:<br />

Mounting height is 60” from the finish floor to the centerline of the sign. (58”.)<br />

Recommendation:<br />

Relocate existing signage.<br />

212


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-132-1 (originally 0454-400)<br />

213


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

133. Doors - Women’s Restroom on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Areas not meeting new construction standards:<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be opened<br />

by a wheelchair footrest without creating a trap or hazardous condition (kick plate). (9”.)<br />

Recommendation:<br />

Install kick-plate to bottom of door.<br />

Photo #UCR P5281 College Building South-133-1 (originally 0455-400)<br />

214


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-133-2 (originally 0456-400)<br />

215


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

134. Clear Space at Doors - Women’s Restroom on the 2nd Floor.<br />

Memo:<br />

See Sequence #136 for recommendations.<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (13” to the cabinet and boxes.)<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-134-1 (originally 0457-400)<br />

216


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-134-2 (originally 0458-400)<br />

217


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

135. Identification Symbols, Restrooms - Women’s Restroom on the 2nd<br />

Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Women’s - 12” diameter circle 1/4” thick. The circle symbol contrasts with the door, light on dark background or dark<br />

on light background. (Incorrect.)<br />

Areas not meeting new construction standards:<br />

Wall mounted signage: Symbol of accessibility is mounted on wall sign adjacent to latch side of door. (None.)<br />

Recommendation:<br />

Install door-mounted sign on single door.<br />

Install wall-mounted sign at single entrance.<br />

Photo #UCR P5281 College Building South-135-1 (originally 0465-400)<br />

218


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

136. Single Accommodation Toilet - Women’s Restroom on the 2nd<br />

Floor.<br />

Memo:<br />

Remove boxes and cabinet.<br />

Areas noted in compliance:<br />

Space for 30” x 48” wheelchair to enter and permit door to close.<br />

Privacy lock, push button, lever release.<br />

28” minimum between the side of the water closet and any fixture or a minimum of 32” clear space between the side of<br />

the water closet to opposite wall or partition.<br />

42” min. clearance between centerline of water closet and opposite wall.<br />

44” max. height to flush valve.<br />

Flush valve is on wide side of the water closet<br />

5 lb. max. force is required to operate the flush valve.<br />

Front of toilet paper dispenser is within 36” of the back wall.<br />

The toilet paper dispenser is located on the side wall below the grab bar and within 12” of the front of the toilet<br />

seat.<br />

19” min. height to toilet paper dispenser.<br />

Toilet paper dispenser provides continuous flow.<br />

Areas not meeting new construction standards:<br />

60” minimum diameter turning circle, or a T-shaped clear space, is provided in room with 12” maximum door encroachment<br />

into the required clear space. (45”.)<br />

18” between centerline of water closet and side wall or partition. (19-1/2”.)<br />

A minimum 60” wide and 48” deep clear floor space is provided in front of water closet. (60” x 23” to boxes.)<br />

The top of the toilet seat is 17” - 19” from the floor surface measured to the top of a maximum 2” high toilet seat<br />

(a 3” high seat shall be permitted only in alterations where the existing fixture is less than 15” high). (19-1/2”.)<br />

Recommendation:<br />

Replace water closet.<br />

Provide a toilet seat to comply with the maximum height requirement of 17” - 19”.<br />

Move boxes, carts, non-fixed trash receptacles, etc. to provide required minimum door swing and/or clear space.<br />

219


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-136-1 (originally 0466-400)<br />

220


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

137. Toilet Grab Bars - Women’s Restroom on the 2nd Floor.<br />

Memo:<br />

Remove window seal.<br />

Areas noted in compliance:<br />

1-1/4” to 1-1/2” diameter of bars.<br />

1-1/2” clearance between bars and each wall or partition.<br />

The side grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor.<br />

Side bar has 42” min. length.<br />

The front of the side grab bar extends 54” from back wall in single accommodation stall.<br />

Side bar begins a max. of 12” from back wall.<br />

Back bar has 36” min. length.<br />

Back bar begins a max. of 6” from side wall.<br />

Bars are smooth with a min. edge radius of 1/8”.<br />

Grab bars do not rotate within their fittings.<br />

Min. structural strength to support 250 lb. point load.<br />

Surface of wall adjacent to grab bars are free of sharp or abrasive elements.<br />

Areas not meeting new construction standards:<br />

The rear grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor (for<br />

tank type toilets, 36” may be allowed if tank obstructs placement of bar). (37-1/2” high.)<br />

Area directly above grab bars or proposed grab bars is free of protruding obstructions to a height of 18” (recessed<br />

items are allowed). (Window - 9” / toilet paper dispenser - 7-3/4”.)<br />

Recommendation:<br />

Relocate grab bar.<br />

Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.<br />

221


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-137-1 (originally 0467-400)<br />

222


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

138. Lavatories - Women’s Restroom on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

30” x 48” min. clear space provided in front of lavatory that allows forward approach (doors may not encroach into this<br />

space).<br />

Required clear space extends 19” max. underneath the lavatory and adjoins or over laps an accessible route.<br />

18” minimum from center of fixture to side wall or partition.<br />

34” max. height to rim or counter above floor surface.<br />

29” min. clearance from bottom of apron to floor surface.<br />

30” wide x 9” high x 17” deep clearance from front of lavatory.<br />

There are no sharp or abrasive elements under lavatory.<br />

Faucets are lever type, electronically activated or approved self closing valves (10 second open flow).<br />

Faucets are operable with one hand and do not require tight grasping, pinching or twisting of wrist.<br />

5 lb. max. force required to operate controls.<br />

Areas not meeting new construction standards:<br />

27” high x 8” deep knee clearance under front lip. (25-1/2” high.)<br />

Drain and piping is insulated or configured to prevent contact. (No insulation.)<br />

Recommendation:<br />

Raise/Lower existing lavatory.<br />

Insulate pipes under lavatory (or sink when applicable).<br />

223


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-138-1 (originally 0468-400)<br />

224


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

139. Accessories - Women’s Restroom on the 2nd Floor.<br />

Memo:<br />

See Sequence #137 for additional recommendations.<br />

Areas noted in compliance:<br />

40” maximum height to bottom of reflective surface of mirror.<br />

Accessories do not require tight grasping, pinching or twisting of the wrist to operate.<br />

A minimum 30” x 48” minimum clear floor or ground space is provided to allow forward or parallel approach to accessories.<br />

A maximum of 5 lbs. force is required to operate mechanisms.<br />

Areas not meeting new construction standards:<br />

40” max. height to all other fixtures (i.e., soap dispensers, towels, toilet seat covers, auto dryers, sanitary napkins, waste<br />

recepatacles, etc.). (Paper towel dispenser - 42” / toilet paper dispenser - 40-1/4” / soap dispenser - 51-1/2”.)<br />

Recommendation:<br />

Relocate the paper towel dispenser / hand dryer.<br />

Relocate the soap dispenser.<br />

Photo #UCR P5281 College Building South-139-1 (originally 0469-400)<br />

225


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

140. Doors - Rooms #200, #210, #212 and #214 on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1/2” non-beveled.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Photo #UCR P5281 College Building South-140-1 (originally 0471-400)<br />

226


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-140-2 (originally 0472-400)<br />

Photo #UCR P5281 College Building South-140-3 (originally 0474-400)<br />

227


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

141. Clear Space at Doors - Rooms #200, #210, #212 and #214 on the<br />

2nd Floor.<br />

Memo:<br />

Four doors.<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (40” to shelves.)<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (6” to shelves.)<br />

Recommendation:<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-141-1 (originally 0475-400)<br />

228


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-141-2 (originally 0476-400)<br />

229


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

142. Doors - Room #213 on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1/2” non-beveled.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Photo #UCR P5281 College Building South-142-1 (originally 0477-400)<br />

230


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-142-2 (originally 0478-400)<br />

Photo #UCR P5281 College Building South-142-3 (originally 0479-400)<br />

231


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

143. Clear Space at Doors - Room #213 on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (46” to the wall.)<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (1” wide to chair x 46”<br />

deep to wall.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-143-1 (originally 0480-400)<br />

232


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-143-2 (originally 0481-400)<br />

233


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

144. Doors - Room #211 on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1/2” non-beveled.)<br />

32” minimum clear width of doorway. (25-1/2”.)<br />

Recommendation:<br />

Replace or modify the threshold.<br />

Replace door(s) and frame (stud wall).<br />

Photo #UCR P5281 College Building South-144-1 (originally 0482-400)<br />

234


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-144-2 (originally 0483-400)<br />

Photo #UCR P5281 College Building South-144-3 (originally 0484-400)<br />

235


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

145. Clear Space at Doors - Room #211 on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (48” to the table.)<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (17” wide x 48” deep.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-145-1 (originally 0485-400)<br />

236


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-145-2 (originally 0486-400)<br />

237


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

146. Aisles - Room #211 on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

None observed.<br />

Areas not meeting new construction standards:<br />

36” minimum width of aisles. (33”.)<br />

Recommendation:<br />

Clear aisle width(s) to comply with minimum required aisle width(s) listed above.<br />

Photo #UCR P5281 College Building South-146-1 (originally 0487-400)<br />

238


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

147. Controls, Operating Mechanisms & Vending Machines. - Room<br />

#211 on the 2nd Floor.<br />

Memo:<br />

Copy machine.<br />

Areas noted in compliance:<br />

Controls and operating mechanisms (handles, coin slots, openings, buttons, etc.) are operable with one hand and do not<br />

require tight grasping, pinching or twisting of the wrist to operate.<br />

Forward Reach to Objects: Minimum 30” x 48” clear floor space for forward approach is provided at object.<br />

Forward Reach to Objects: Highest operable part of object is a maximum of 48” above the floor surface.<br />

Forward Reach to Objects: Lowest operable part of object is a minimum of 15” above the floor surface.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-147-1 (originally 0488-400)<br />

239


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

148. Doors - South Stairwell on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

5 lb. maximum pressure to operate interior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

32” minimum clear width of doorway. (28”.)<br />

Recommendation:<br />

Replace door(s) and frame (stud wall).<br />

Photo #UCR P5281 College Building South-148-1 (originally 0489-400)<br />

240


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-148-2 (originally 0490-400)<br />

241


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

149. Clear Space at Doors - South Stairwell on the 2nd Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

60” min. clear space in direction of door swing. (41” to the printer table.)<br />

44” min. clear space opposite direction of door swing (48” with latch and closer). (7” to steps.)<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (18” wide x 41” deep.)<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Relocate furniture to provide clear space.<br />

Photo #UCR P5281 College Building South-149-1 (originally 0491-400)<br />

242


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5281 College Building South-149-2 (originally 0493-400)<br />

243