DR. A. <strong>Kuntze</strong><br />
product catalogue 2013<br />
<strong>pH</strong>/ <strong>ORP</strong><br />
valid from 01.01.2013<br />
subject to alterations
<strong>pH</strong>/ <strong>ORP</strong><br />
Contents<br />
Systems ....................................................................................................................................... 4<br />
BalanceCon ................................................................................................................................ 4<br />
Instruments .................................................................................................................................. 9<br />
Neon pR ..................................................................................................................................... 9<br />
K 100 (W) PR ............................................................................................................................ 17<br />
Sensors ...................................................................................................................................... 23<br />
Zirkon <strong>pH</strong> .................................................................................................................................. 23<br />
Zirkon <strong>pH</strong> process ..................................................................................................................... 28<br />
Zirkon <strong>pH</strong> fluoride ...................................................................................................................... 33<br />
Zirkon <strong>pH</strong> process refill ............................................................................................................... 38<br />
Zirkon <strong>pH</strong> pure .......................................................................................................................... 44<br />
Zirkon <strong>pH</strong> coating ...................................................................................................................... 50<br />
Zirkon <strong>pH</strong> Pool .......................................................................................................................... 55<br />
Zirkon Rx .................................................................................................................................. 60<br />
Zirkon Rx process ...................................................................................................................... 65<br />
Zirkon Rx process refill ............................................................................................................... 70<br />
Zirkon Rx Pool ........................................................................................................................... 76<br />
Zirkon REF ................................................................................................................................ 80<br />
Zirkon REF process refill ............................................................................................................ 85<br />
Zirkon T .................................................................................................................................... 90<br />
Assemblies ................................................................................................................................ 94<br />
GD 1 V(G) (PP)......................................................................................................................... 94<br />
GD 43 ....................................................................................................................................... 96<br />
GE 251 PP ................................................................................................................................ 98<br />
GE 23/3 PP ............................................................................................................................. 101<br />
Handheld Units ........................................................................................................................ 104<br />
PM 6 ....................................................................................................................................... 104<br />
PH-T ....................................................................................................................................... 107<br />
Accessories ............................................................................................................................. 110<br />
S-341 data logger .................................................................................................................... 110<br />
COAX-D-AE-X ......................................................................................................................... 112<br />
TRIAX-D-1-X ........................................................................................................................... 114<br />
IWA 11.4 ................................................................................................................................. 115<br />
2CORE-D-1-X ......................................................................................................................... 117<br />
<strong>pH</strong> buffer solutions .................................................................................................................. 118
BalanceCon<br />
Systems<br />
BalanceCon<br />
High operation safety by defined reaction time in the marble filter<br />
Low maintenance by automatic zero calibration<br />
Integrated controller for optimum decarbonisation<br />
Applications<br />
<strong>Dr</strong>inking Water /<br />
Beverages<br />
Cooling water<br />
BalanceCon in a panel<br />
Description<br />
The measurement is based on the <strong>pH</strong>-difference method described in DIN 38404-10 : 1995-04 Calcit saturation of<br />
water. Automatic zero-point calibration of the <strong>pH</strong>-difference measurement. Reaction time in the marble filter<br />
controlled by stepmotor-driven peristaltic pumps Two separate controllers both of which can be assigned to the <strong>pH</strong><br />
value of the incoming water or after the marble filter or to the <strong>pH</strong> difference.<br />
Particular characteristics<br />
2 limit values with delay, assigned to alarm relay for <strong>pH</strong> value or difference<br />
2 separate PID controllers for <strong>pH</strong> value or difference<br />
Automatic zero calibration of the <strong>pH</strong> difference in adjustable time interval<br />
Semi-automatic two-point-calibration<br />
Manual or automatic temperature compensation by integrated Pt100<br />
Background illuminated four-line LC-Display for <strong>pH</strong> value and <strong>pH</strong> difference or <strong>pH</strong> value<br />
before and after marble filter or <strong>pH</strong> value and temperature<br />
4 x scaleable, galvanically isolated 0/4 .. 20 mA outputs<br />
Option: serial interface RS 485<br />
4
BalanceCon<br />
Systems<br />
Block diagram<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
0.00.. 14.00 <strong>pH</strong> measuring value 1: before the filter<br />
0.00.. 14.00 <strong>pH</strong> measuring value 2: after the filter<br />
-0.5.. +0.5 <strong>pH</strong> <strong>pH</strong> difference (measuring value 2 - measuring value 1)<br />
Input characteristics<br />
Accuracy<br />
+/- 0.02 <strong>pH</strong><br />
Temperature measuring range -30.. +140°C display range<br />
Ambient conditions Flow min. 15 l/h<br />
Min. conductivity > 150 µS/cm<br />
Temperature 0.. 50 °C<br />
5
BalanceCon<br />
Systems<br />
Output characteristics<br />
Alarm relay<br />
1 x potential-free CO-contact, max. 250 V, 6A, 550 VA for alarm<br />
Output signal<br />
4x 0/4.. 20 mA (scaleable, galvanic isolated)<br />
Load<br />
max. 500 Ohm<br />
Registration range Scaleable within the measuring range<br />
Serial interface Option: RS 485<br />
Baud rate<br />
9600 baud<br />
Data format 8 bit<br />
Power supply<br />
Line voltage<br />
Power consumption<br />
Wide range power supply 85.. 265 V AC oder DC<br />
36 VA<br />
Ambient conditions<br />
Temperature Storage -20.. +65°C, exception sensors 0..<br />
+30°C<br />
Operation 0.. 50°C<br />
Protection class Wall mounted IP 54<br />
Controller<br />
Control mode<br />
On/off controller (adjustable hysteresis) P/PI/PID-controller (pulse-pause,<br />
pulse-frequency or continous controller output)<br />
Relay<br />
2 x potential-free NO-contact, max. 250 V, 6 A, 550 VA for activation dosing<br />
pumps / Servo-motor<br />
Start delay<br />
0.. 200 sec until controller active<br />
Digital input 1) low water 2) Ext. Initiation of the automatic zero-point calibration 3)<br />
external controller stop<br />
Design configuration<br />
Material<br />
Dimensions<br />
board: PVC, assembly: PVC, cocks: PP instrument: ABS, sensors: glass<br />
550 x 545 x 150 mm<br />
6
BalanceCon<br />
Systems<br />
Mechanical drawing<br />
BalanceCon<br />
Storage version<br />
Article number type/configuration Description<br />
77612729K BalanceCon Measuring system to measure and control calcite solubility<br />
7
BalanceCon<br />
Systems<br />
Accessories<br />
accessories<br />
BalanceCon cabinet External dimensions (W x H x D): 600 x 600 x 200<br />
mm, door with integrated inspection glass made of<br />
3mm impact resistant acryl glass<br />
<strong>pH</strong> buffer solutions<br />
The slope of <strong>pH</strong> sensors changes over the time<br />
(depending on the measuring media). We recomment<br />
a regular calibration with our buffer solutions. We offer<br />
1000 ml packages of <strong>pH</strong> 2, <strong>pH</strong> 3,56, <strong>pH</strong> 4, <strong>pH</strong> 7, and<br />
<strong>pH</strong> 9,22, and 50 ml packages of <strong>pH</strong> 4, and <strong>pH</strong> 7.<br />
BalanceCon<br />
refill-set<br />
Refill-set for the filter, 600 g pellets<br />
sensors<br />
201012100 The sensor of the Zirkon <strong>pH</strong> series are highly<br />
sophisticated sensors with a high value for money<br />
ratio. They are used in many applications e.g.<br />
industrial, process and waste water. We use our high<br />
performance AH glass with low alkaline error and a<br />
broad temperature range. We use a high class<br />
ceramic junction which increases the sensor life<br />
expectancy and our low maintenance Topax gel. As<br />
reference system we use a cartridge system which<br />
results for a constant measurement especially in<br />
applications with high temperature fluctuations.<br />
8
Neon pR<br />
Instruments<br />
Neon pR<br />
Easy handling by graphical menue<br />
Fitting for your application by modular setup<br />
Comfortable by firmware update and configuration via SD card<br />
Applications<br />
Process Water<br />
<strong>Dr</strong>inking Water /<br />
Beverages<br />
Waste Water Treatment<br />
Neon Touch wall mounted housing<br />
Description<br />
Neon is a modern measuring and control instrument, whose scope of functions you can determine according to your<br />
application. The basic version contains inputs for measurement and temperature, key operation, one digital input<br />
and one alarm relay. Via codes and add-on modules you can add one or two analog outputs, control functions either<br />
concentration-based or volume-based, as well as various digital output functions such as modbus interface,<br />
Ethernet, webserver, or datalogger. You can even adjust what information you want to see in the display. And if you<br />
have to install more than one instrument of the same type with the same settings, settings can easily be multiplied<br />
via SD card. Use the full advantages of the graphical menus with our touch screen version Neon Touch! Neon pR is<br />
used for <strong>pH</strong> and <strong>ORP</strong> measurements.<br />
9
Neon pR<br />
Instruments<br />
Particular characteristics<br />
85 .. 265 V AC power supply<br />
Guided two point calibration<br />
Logging of the last 10 calibration data<br />
Automatic or manual temperature compensation<br />
2 user levels by password function<br />
Safety by autolock function<br />
Power saving adjustable<br />
Alerts selectable for alarm relay<br />
SD card function: firmware update, configuration and diagnosis file<br />
Test menu for wiring check<br />
Real time clock<br />
Eventlog and event help<br />
Functional upgrade by activation code or with modules<br />
Option: 2 mA outputs 0/4 to 20 mA adjustable with fault current<br />
Option: data log function<br />
Option: RS 485 Modbus RTU<br />
Option: Ethernet with internal webserver<br />
Option: 24 V DC<br />
Option: 2nd digital input<br />
Option: 2 PID controller with digital output<br />
Option: volume-based dosage with measurement<br />
10
Neon pR<br />
Instruments<br />
Block diagram<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
<strong>ORP</strong><br />
-2.00.. +16.00 <strong>pH</strong><br />
-1500.. +1500 mV<br />
Input characteristics<br />
Temperature measuring range -30.0 .. +140.0 °C<br />
Temperature coefficient<br />
Non-linear<br />
Digital input<br />
1 as controller stop by external contact option: 2nd as controller stop or flow<br />
measurement for volume based dosing<br />
11
Neon pR<br />
Instruments<br />
Output characteristics<br />
Alarm relay<br />
Output signal<br />
Voltage output<br />
Storage media<br />
Serial interface<br />
1 potential-free NO contact, max. 250 V, 6 A, 550 VA (invertable)<br />
Option: 2 x 0/4 .. 20 mA (scaleable, galvanically isolated)<br />
Load<br />
500 Ohm<br />
Registration range Scaleable within the measuring range<br />
+/- 6 VDC for impedance converter<br />
Accessorie: SD card up to 2 MB - industrial standard<br />
Option: RS 485 modbus RTU<br />
Baud rate<br />
19200 bps<br />
Data format 8 bit<br />
Ethernet<br />
Option: internal webserver<br />
Power supply<br />
Line voltage<br />
Power consumption<br />
85.. 250 V AC, +6/-10%, 40.. 60Hz option: 24 V DC<br />
10 VA<br />
Ambient conditions<br />
Temperature Storage -20.. +65°C<br />
Operation<br />
-5.. +50°C<br />
Humidity<br />
max. 90% rH at 40°C (non-condensing)<br />
Protection class Wall mounted IP 65<br />
Panel mounted IP 54 (front), IP 30 (housing)<br />
Controller<br />
Control response<br />
Relay<br />
Start delay<br />
Controller stop<br />
Option: on/off controller (adjustable hysteresis) P/PI/ PID controller<br />
(pulse-pause, pulse-frequency or continuous output) servo motor control<br />
2 relays, each with a potential-free NO contact, max. 250V, 6 A, 550 VA<br />
0.. 200 sec until controller active<br />
Digital input<br />
Proportion to volume<br />
Control mode<br />
Option: quantity based by flow measurement<br />
Flow measurement Impuls measurement NPN (by digital input 2)<br />
Flow measurement Engine speed 0.030.. 9.999 l/Imp<br />
Relay 1<br />
Potential-free NO contact, max. 250V, 6 A, 550 VA output of<br />
control variable as pulse frequency or pulse pause.<br />
Relay 2<br />
Activating circulation pump<br />
Certificates and approvals<br />
CE-Symbol<br />
The product meets the requirements of the harmonized European standards.<br />
It thus complies with the legal requirements of the EC directives.<br />
EMV/EMC EN 61000 6-1 (3) EN 61000 6-2 (4) EN 61326-1<br />
12
Neon pR<br />
Instruments<br />
Design configuration<br />
Material<br />
Dimensions<br />
Mounting dimension<br />
Weight<br />
Connection<br />
ABS<br />
Panel mounted housing: 138x138x83 mm; Wall mounted housing:<br />
144x144x156 mm<br />
Panel mounted housing: 138x138x42 mm<br />
0.6 kg (wall mounted housing: 1 kg)<br />
Cable inlet: 2x M16, 2x M12 + optional: 2x M12 and 1x M25 plug-in terminal:<br />
rigid /flexible 0.2-2.5 mm² / 0.2-2.5 mm² measurement rigid /flexible 0.2-1<br />
mm² / 0.2-1.5 mm²<br />
Mechanical drawing<br />
Panel mounted housing<br />
13
Neon pR<br />
Instruments<br />
Wall mounted housing<br />
14
Neon pR<br />
Instruments<br />
Order information<br />
Choose the components you need and that´s how your "assembly version" is designed. We will have to technically<br />
inspect and approve a free combination of individual key features.<br />
15
Neon pR<br />
Instruments<br />
Accessories<br />
accessories<br />
<strong>pH</strong> buffer solutions<br />
The slope of <strong>pH</strong> sensors changes over the time<br />
(depending on the measuring media). We recomment<br />
a regular calibration with our buffer solutions. We offer<br />
1000 ml packages of <strong>pH</strong> 2, <strong>pH</strong> 3,56, <strong>pH</strong> 4, <strong>pH</strong> 7, and<br />
<strong>pH</strong> 9,22, and 50 ml packages of <strong>pH</strong> 4, and <strong>pH</strong> 7.<br />
Measuring point setup<br />
16
K 100 (W) PR<br />
Instruments<br />
K 100 (W) PR<br />
Easy and save operation by plain text menu guidance<br />
Safety by password function<br />
Applications<br />
Waste Water Treatment<br />
Cooling water<br />
<strong>Dr</strong>inking Water /<br />
Beverages<br />
K 100 W PR<br />
Process Water<br />
Description<br />
The K 100 (W) PR is a sophisticated single-channel instrument for measuring and control the <strong>pH</strong>-value or the <strong>ORP</strong>.<br />
Additionaly temperature measurement of the measuring media is possible. The instrument is available in a panel<br />
mounted housing (K100 PR) and in a wall mounted housing (K 100 W PR).<br />
Particular characteristics<br />
2 limit values with delay, assigned to alarm relay<br />
2 integrated PI-controller<br />
Dosage check<br />
Semi-automatic two-point-calibration for <strong>pH</strong><br />
Slope and zero point monitoring for <strong>pH</strong><br />
Automatic or manual <strong>pH</strong>-value compensation<br />
Background illuminated two-line LC-Display for measured value and temperature<br />
Scaleable, galvanically isolated 0/4..20 mA output<br />
Display of relay and error messages<br />
Invertible alarm output, permanent or pulse contact<br />
Option: serial interface RS 485<br />
17
K 100 (W) PR<br />
Instruments<br />
Block diagram<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
<strong>ORP</strong><br />
-2.00.. +16.00 <strong>pH</strong><br />
-1500.. +1500 mV<br />
Input characteristics<br />
Temperature measuring range<br />
Digital input<br />
-30.. +140 °C (display range)<br />
1 as controller stop as external contact<br />
18
K 100 (W) PR<br />
Instruments<br />
Output characteristics<br />
Alarm relay<br />
1 potential-free NO contact, max. 250 V, 6 A, 550 VA<br />
Output signal<br />
1 x 0/4.. 20 mA (scaleable, galvanic isolated)<br />
Load<br />
max. 500 Ohm<br />
Registration range Scaleable within the measuring range<br />
Voltage output<br />
+/- 6 VDC for impedance converter<br />
Serial interface Option: RS 485<br />
Baud rate<br />
9600 baud<br />
Data format 8 bit<br />
Power supply<br />
Line voltage<br />
Power consumption<br />
24 / 117/ 230 VAC, +6/-10%, 40.. 60 Hz<br />
10 VA<br />
Ambient conditions<br />
Temperature Storage -20.. +65°C<br />
Operation 0.. 50°C<br />
Protection class Wall mounted IP 65<br />
Panel mounted IP 54 (front), IP 30 (housing)<br />
Controller<br />
Control response<br />
Relay<br />
Start delay<br />
Controller stop<br />
on/off controller (adjustable hysteresis) P/PI controller (pulse-pause,<br />
pulse-frequency or continuous output)<br />
2 relays, each with a potential-free NO contact, max. 250V, 6 A, 550 VA<br />
0.. 200 sec until controller active<br />
Digital input<br />
Certificates and approvals<br />
CE-Symbol<br />
EMV/EMC<br />
The product meets the requirements of the harmonized European standards.<br />
It thus complies with the legal requirements of the EC directives.<br />
EN 61326 Klasse B, 2004/108/EG<br />
Design configuration<br />
Material<br />
Dimensions<br />
Mounting dimension<br />
Weight<br />
Panel mounted housing: Noryl; Wall mounted hosuing: ABS<br />
Panel mounted housing: 90x90x116 mm; Wall mounted housing: 165x160x85<br />
mm<br />
Panel mounted housing: 92x92x140 mm<br />
Panel mounted housing: 0,75 kg; Wall mounted housing: 0,95 kg<br />
19
K 100 (W) PR<br />
Instruments<br />
Mechanical drawing<br />
Wall mounted housing<br />
Panel mounted housing<br />
20
K 100 (W) PR<br />
Instruments<br />
Storage version<br />
Article number type/configuration Description<br />
100000K K 100 PR <strong>pH</strong> or <strong>ORP</strong> and T single measurement, panel mounted housing, 230 V<br />
105000K K 100 W PR <strong>pH</strong> or <strong>ORP</strong> and T single measurement<br />
21
K 100 (W) PR<br />
Instruments<br />
Accessories<br />
accessories<br />
<strong>pH</strong> buffer solutions<br />
The slope of <strong>pH</strong> sensors changes over the time<br />
(depending on the measuring media). We recomment<br />
a regular calibration with our buffer solutions. We offer<br />
1000 ml packages of <strong>pH</strong> 2, <strong>pH</strong> 3,56, <strong>pH</strong> 4, <strong>pH</strong> 7, and<br />
<strong>pH</strong> 9,22, and 50 ml packages of <strong>pH</strong> 4, and <strong>pH</strong> 7.<br />
S-341 data logger The bus data logger S-341 on the base of the RS-485<br />
with <strong>Kuntze</strong> protocol reads, shows, and stores<br />
measuring data of up to 10 <strong>Kuntze</strong> instruments with<br />
up to 8 parameters each.<br />
Measuring point setup<br />
22
Zirkon <strong>pH</strong><br />
Sensors<br />
Zirkon <strong>pH</strong><br />
Low maintenance by gel filling<br />
High precision by use of high alkaline high temperature glass<br />
Made in Germany<br />
Applications<br />
Process Water<br />
<strong>Dr</strong>inking Water /<br />
Beverages<br />
Waste Water Treatment<br />
201012103 201112400 201012100<br />
Description<br />
The sensor of the Zirkon <strong>pH</strong> series are highly sophisticated sensors with a high value for money ratio. They are used<br />
in many applications e.g. industrial, process and waste water. We use our high performance AH glass with low<br />
alkaline error and a broad temperature range. We use a high class ceramic junction which increases the sensor life<br />
expectancy and our low maintenance Topax gel. As reference system we use a cartridge system which results for a<br />
constant measurement especially in applications with high temperature fluctuations.<br />
23
Zirkon <strong>pH</strong><br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
0.. 14 <strong>pH</strong><br />
Ambient conditions<br />
Max. pressure<br />
< 2 bar<br />
Min. condutctivity<br />
> 150 µS/cm<br />
Temperature -5.. +70 °C<br />
plug PG resin shaft PG 13,5 loose<br />
Pressure < 2 bar at 20°C < 1 bar at 20°C < 1 bar at 20°C<br />
Mechanical construction<br />
Junction<br />
ceramic 1 mm<br />
Shaft material<br />
glass, resin<br />
Mechanical Construction<br />
120 mm, 160 mm<br />
Electrode material<br />
AH-Glas ball<br />
Reference system<br />
Ag/AgCl/Tepox gel Ag/AgCl/Tepoxgel - saturated KCl<br />
Internal buffer <strong>pH</strong> 7<br />
Mechanical connection<br />
S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />
cable<br />
Electrical connection<br />
2 or 6 pole connection<br />
Temperature sensor<br />
none, Pt100, Pt1000<br />
24
Zirkon <strong>pH</strong><br />
Sensors<br />
Mechanical drawing<br />
S8 plug<br />
SP Sixplug<br />
201012100 resin shaft<br />
S7 plug<br />
201012320<br />
25
Zirkon <strong>pH</strong><br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
26
Zirkon <strong>pH</strong><br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24131110K 201012100 <strong>pH</strong> sensor: Tepoxgel, 120 mm, ceramic junction, S8 screw plug,<br />
follow-up of AH-300-K-2-1-PG<br />
24131100K 201012320 <strong>pH</strong> sensor: Tepoxgel, 160 mm, ceramic junction, S7 plug, follow-up of<br />
AH-300-K-2-1<br />
Assembly version<br />
Article number type/configuration Description<br />
24132650K 201012103 <strong>pH</strong> sensor: Tepox gel, 120 mm, ceramic junction, S8 screw plug,<br />
follow-up of AH-320-K-2-1-PG<br />
24132111K 201112400 <strong>pH</strong> sensor: Tepox gel, 120 mm, ceramic junction, sixplug, follow-up of<br />
AH-305-K-2-1-PG<br />
27
Zirkon <strong>pH</strong> process<br />
Sensors<br />
Zirkon <strong>pH</strong> process<br />
Low maintenance by gel or solid filling<br />
Dirt resistant by premium-quality junctions<br />
Made in Germany<br />
Applications<br />
Waste Water Treatment<br />
Process Water<br />
Cooling water<br />
203038390 203072100 203085100<br />
Description<br />
The sensors of the Zirkon <strong>pH</strong> process series are highly sophisticated sensors with a high value for money ratio. They<br />
are used in applications like process and waste water. We use our high performance AH glass with low alkaline error<br />
and a broad temperature range. We use different materials like ceramic, platinum or PTFE as junction. The junction<br />
is among other things responsible for the salt output and the dirt resistance. As electrolyte we use our low<br />
maintenance Topax gel. As reference system we use a cartridge system which results in a constant measurement<br />
even in applications with high temperature fluctuations.<br />
28
Zirkon <strong>pH</strong> process<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
0.. 14 <strong>pH</strong><br />
Ambient conditions<br />
Max. pressure 0.. 10 bar at 20°C<br />
Min. condutctivity<br />
> 150 µS/cm<br />
Temperature -5.. +70 °C<br />
PTFE Hole Ceramic Platin<br />
Pressure < 10 bar at 20 °C < 1 bar pressure less < 2 bar at 20 °C < 2 bar at 20 °C<br />
plug PG PG 13,5 loose<br />
Pressure < 10 bar at 20 °C < 1 bar at 20°C<br />
Mechanical construction<br />
Junction<br />
ceramic 1mm, zircon, platinum, PTFE, hole<br />
Shaft material<br />
Glass<br />
Mechanical Construction<br />
120 mm, 160 mm, 220 mm (double chamber), 240 mm<br />
Electrode material<br />
AH glass ball<br />
Reference system<br />
Ag/AgCl/Tepox gel, Ag/AgCl/solid electrolyte, Ag/AgCl/Tepox gel - 3M KCl<br />
liquid<br />
Internal buffer <strong>pH</strong> 7<br />
Mechanical connection<br />
S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />
cable<br />
Electrical connection<br />
2 or 6 pole connection<br />
Temperature sensor<br />
none, Pt100, Pt1000<br />
29
Zirkon <strong>pH</strong> process<br />
Sensors<br />
Mechanical drawing<br />
S8 screw plug<br />
Sixplug<br />
203032100 ceramic PTFE hole<br />
S7 plug<br />
203038390<br />
30
Zirkon <strong>pH</strong> process<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
31
Zirkon <strong>pH</strong> process<br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24132150K 203032100 <strong>pH</strong> sensor: Tepox gel, 120 mm, platinum junction, S8 srew plug,<br />
follow-up of AH-300-K-2-3-PG<br />
24132140K 203032320 <strong>pH</strong> sensor: Tepox gel, 160 mm, platinum junction, S7 plug, follow-up of<br />
AH-300-K-2-3<br />
24132120K 203072100 <strong>pH</strong> sensor, Tepox gel, 120 mm, PTFE junction, S8 screw plug,<br />
follow-up of AH-300-K-2-7-PG<br />
24132121K 203172400 <strong>pH</strong> sensor: Tepox gel, 120 mm, PTFE junction, Pt 100, sixplug,<br />
follow-up of AH-305-K-2-7-PG<br />
Assembly version<br />
Article number type/configuration Description<br />
24132810K 203085100 <strong>pH</strong> sensor: solid electrolyte, hole, S8 srew plug, 120mm, follow-up of<br />
AH-300-K-5-8-PG<br />
24132501K 203038390 double chamber <strong>pH</strong> sensor: Tepox gel inside3M KCl liquid outside,<br />
platinum junction, S7 plug, 220mm, follow-up of AH-310-K-4-3<br />
32
Zirkon <strong>pH</strong> fluoride<br />
Sensors<br />
Zirkon <strong>pH</strong> fluoride<br />
Fluoride resistant<br />
Low maintenance by gel filling / Long life expectancy by refillable reference electrode<br />
Made in Germany<br />
Applications<br />
Fluoride Containing<br />
Media<br />
205011320 205072130 205072100<br />
Description<br />
Sensors of the series Zirkon <strong>pH</strong> fluoride are developed for the application in fluoride containing media. The special<br />
glass is resistant up to 500 m/l fluoride. The sensors are mainly used in the semiconducter industry. The sensor<br />
design such as like reference electrode and junction are mainly determined by the water characteristics.<br />
33
Zirkon <strong>pH</strong> fluoride<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
1.. 11 <strong>pH</strong><br />
Ambient conditions<br />
Max. pressure<br />
0.. 10 bar<br />
Min. condutctivity<br />
> 150 µS/cm<br />
Temperature 0.. 60 °C<br />
3M KCl Tepox gel<br />
Condutctivity > 50 µS/cm > 150 µS/cm<br />
plug PG PG 13,5 loose<br />
Pressure 0.. 10 bar at 20°C < 1 bar at 20°C<br />
PTFE hole ceramic platinum<br />
Pressure < 10 bar at 20°C < 1 bar pressureless < 2 bar at 20°C < 2 bar at 20°C<br />
Mechanical construction<br />
Junction<br />
ceramic 1 mm, zircon, PTFE, platinum, hole<br />
Shaft material<br />
Glass<br />
Mechanical Construction<br />
120 mm, 160 mm, 240 mm<br />
Electrode material<br />
S-glass-ball<br />
Reference system<br />
Ag/AgCl/3M KCl, Ag/AgCl/Tepox gel Ag/AgCl/solid electrolyte<br />
Internal buffer <strong>pH</strong> 7<br />
Mechanical connection<br />
S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />
cable<br />
Electrical connection<br />
2 or 6 pole connection<br />
Temperature sensor<br />
none, Pt100, Pt1000<br />
34
Zirkon <strong>pH</strong> fluoride<br />
Sensors<br />
Mechanical drawing<br />
S8 screw plug<br />
205012100 PTFE<br />
S7 plug<br />
205011320 hole ceramic<br />
35
Zirkon <strong>pH</strong> fluoride<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
36
Zirkon <strong>pH</strong> fluoride<br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24132410K 205012100 <strong>pH</strong> sensor: Tepox gel, 120 mm, ceramic junction, S8 screw plug,<br />
follow-up of S-300-K-2-1-PG<br />
24132400K 205012320 <strong>pH</strong> sensor: Tepox gel, 160 mm, ceramic junction, S7 plug, follow-up of<br />
S-300-K-2-1<br />
24132420K 205072100 <strong>pH</strong> sensor: Tepox gel, 120 mm, PTFE junction, S8 screw plug,<br />
follow-up of S-300-K-2-7-PG<br />
Assembly version<br />
Article number type/configuration Description<br />
24132300K 205011320 <strong>pH</strong> sensor: 3M KCl, 160 mm, ceramic junction, S7 plug, follow-up of<br />
S-300-K-1-1<br />
24132421K 205072130 <strong>pH</strong> sensor: Tepox gel, 240 mm, PTFE junction, S8 screw plug,<br />
follow-up of S-300-K-2-7-PG-240<br />
37
Zirkon <strong>pH</strong> process refill<br />
Sensors<br />
Zirkon <strong>pH</strong> process refill<br />
Long life expectancy by refillable reference electrode<br />
High precision by use of high alkaline high temperature glass<br />
Made in Germany<br />
Applications<br />
Process Water<br />
<strong>Dr</strong>inking Water /<br />
Beverages<br />
Waste Water Treatment<br />
204031320 204017390 204011320<br />
Description<br />
The sensors of the Zirkon <strong>pH</strong> process series are highly sophisticated sensors with a high value for money ratio. They<br />
are used in applications like process and waste water. We use our high performance AH glass with low alkaline error<br />
and a broad temperature range. We use different materials like ceramic, platinum or PTFE as junction. The junction<br />
and the electrolyte determine the salt output and the dirt resistance. As electrolyte we use our 3M KCl - this is<br />
refillable. As reference system we use a cartridge system which results in a constant measurement especially in<br />
applications with high temperature fluctuations.<br />
38
Zirkon <strong>pH</strong> process refill<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
0.. 14 <strong>pH</strong><br />
Ambient conditions<br />
Max. pressure<br />
< 1 bar pressureless<br />
Min. condutctivity<br />
> 50 µS/cm<br />
Temperature -5.. +100 °C<br />
plug PG PG 13,5 loose<br />
Pressure < 2 bar at 20°C < 1 bar at 20°C<br />
Mechanical construction<br />
Junction<br />
ceramic 1 mm, zircon, platinum, PTFE<br />
Shaft material<br />
Glass<br />
Mechanical Construction<br />
120 mm, 160 mm, 240 mm<br />
Electrode material<br />
AH glass ball<br />
Reference system<br />
Ag/AgCl/3M KCl liquid, Ag/AgCl/3M KCl liquid - 3M KCl liquid<br />
Internal buffer <strong>pH</strong> 7, <strong>pH</strong> 2<br />
Mechanical connection<br />
S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />
cable<br />
Electrical connection<br />
2 or 6 pole connection<br />
Temperature sensor<br />
none, Pt100, Pt1000<br />
39
Zirkon <strong>pH</strong> process refill<br />
Sensors<br />
Mechanical drawing<br />
204011320<br />
204017390<br />
40
Zirkon <strong>pH</strong> process refill<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
41
Zirkon <strong>pH</strong> process refill<br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24132040K 204011320 <strong>pH</strong> sensor: 3M KCI liquid, 160mm, ceramic junction, S7 plug, follow-up<br />
of AH-300-K-1-1<br />
24132050K 204031320 <strong>pH</strong> sensor: 3M KCl liquid, 160mm, platinum junction, S7 plug, follow-up<br />
of AH-300-K-1-3<br />
Assembly version<br />
Article number type/configuration Description<br />
24132510K 204017390 double chamber <strong>pH</strong> sensor: 3M KCI liquid inside and outside, 220mm,<br />
ceramic junction, S7 plug, follow-up model of AH-310-K-3-1<br />
42
Zirkon <strong>pH</strong> process refill<br />
Sensors<br />
Accessories<br />
accessories<br />
KCl vessel set<br />
Vessel-set for KCl liquid-filled <strong>pH</strong> or <strong>ORP</strong> sensors.<br />
The installation is possible on a wall or in the<br />
immersion assembly GE 23/3.<br />
Service-Set GE<br />
PG screw for sensors with 12 mm diameter. This<br />
screw enables the installation of liquid-filled sensors<br />
in the immersion assembly GE 23/3 or in the flow<br />
assembly GD (1) VG and GD (3) VG.<br />
43
Zirkon <strong>pH</strong> pure<br />
Sensors<br />
Zirkon <strong>pH</strong> pure<br />
Long life time by refillable reference electrode<br />
Measurement in media with very low conductivities by a higher flow rate<br />
Made in Germanry<br />
Applications<br />
Cooling water<br />
Ultra Pure Water<br />
Description<br />
202041320 202061320<br />
The sensors of the Zirkon <strong>pH</strong> pure are highly sophisticated sensors with a high value for money ratio. They are used<br />
in ion poor media. We use our high performance AH glass with low alkaline error and a broad temperature range.<br />
We use different materials like ceramic or glass sleeve as junction. The junction and the electrolyte are determine<br />
the salt output and therfore the measurement quality in ion poor media. As electrolyte we use our 3M KCl - this is<br />
refillable. As reference system we use a cartridge system which results in a constant measurement especially in<br />
applications with high temperature fluctuations.<br />
44
Zirkon <strong>pH</strong> pure<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
0.. 14 <strong>pH</strong><br />
Ambient conditions<br />
Max. pressure<br />
< 1 bar pressureless<br />
Temperature -5.. +100 °C<br />
3x2 mm ceramic glass sleeve<br />
Condutctivity > 50 µS/cm > 20 µS/cm<br />
plug PG PG 13,5 loose<br />
Pressure < 2 bar at 20 °C < 1 bar pressureless<br />
Mechanical construction<br />
Junction<br />
3 x 1 mm ceramic, glass sleeve<br />
Shaft material<br />
Glass<br />
Mechanical Construction<br />
160 mm<br />
Electrode material<br />
AH glass<br />
Reference system<br />
Ag/AgCl/3M KCl liquid<br />
Internal buffer <strong>pH</strong> 7<br />
Mechanical connection<br />
S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />
cable<br />
Electrical connection<br />
2 or 6 pole connection<br />
Temperature sensor<br />
none, Pt100, Pt1000<br />
45
Zirkon <strong>pH</strong> pure<br />
Sensors<br />
Mechanical drawing<br />
202041320<br />
202061320<br />
46
Zirkon <strong>pH</strong> pure<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
47
Zirkon <strong>pH</strong> pure<br />
Sensors<br />
Assembly version<br />
Article number type/configuration Description<br />
24132070K 202041320 <strong>pH</strong> sensor: 3M KCl liquid, 160 mm, ceramic junction, 160mm, follow-up<br />
model of AH-300-K-1-3x2<br />
24132010K 202061320 <strong>pH</strong> sensor: 3M KCl liquid, 160 mm, glass sleeve, S7 plug, 160mm,<br />
follow-up model of AH-300-K-1-6<br />
48
Zirkon <strong>pH</strong> pure<br />
Sensors<br />
Accessories<br />
accessories<br />
KCl vessel set<br />
Vessel-set for KCl liquid-filled <strong>pH</strong> or <strong>ORP</strong> sensors.<br />
The installation is possible on a wall or in the<br />
immersion assembly GE 23/3.<br />
Service-Set GE<br />
PG screw for sensors with 12 mm diameter. This<br />
screw enables the installation of liquid-filled sensors<br />
in the immersion assembly GE 23/3 or in the flow<br />
assembly GD (1) VG and GD (3) VG.<br />
49
Zirkon <strong>pH</strong> coating<br />
Sensors<br />
Zirkon <strong>pH</strong> coating<br />
Junction protectable<br />
Fluoride resistant<br />
According to DIN 55659 for <strong>pH</strong> measurement in electrophoretic dip painting<br />
Applications<br />
Laboratory<br />
Fluoride Containing<br />
Media<br />
Description<br />
206051320<br />
Sensors of the Zirkon <strong>pH</strong> coating series are developed for the use in lacquer and coatings. They are used in paint<br />
and coating industry. Crucial for the measurement in coatings is the contamination of the junction. This mainly<br />
determines the life expectancy of the sensor. In case of the Zirkon <strong>pH</strong> coating sensors the projecting junction can be<br />
protected with a membrane or a hole is used in combination with solid electrolyte instead of a junction.<br />
50
Zirkon <strong>pH</strong> coating<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value 1.00.. 11.00<br />
Ambient conditions<br />
Max. pressure<br />
< 1 bar pressure less<br />
Min. condutctivity<br />
> 50 µS/cm<br />
Temperature 0.. +60 °C<br />
KCl 3M liquid solid electrolyte<br />
Condutctivity > 50 µS/cm > 150 µS/cm<br />
Mechanical construction<br />
Junction<br />
ceramic 15 mm projecting, hole<br />
Shaft material<br />
Glass<br />
Mechanical Construction<br />
120 mm, 160 mm, 240 mm<br />
Electrode material<br />
S-Glass ball<br />
Reference system<br />
Ag/AgCl/3M KCl, Ag/AgCl/solid electrolyte<br />
Internal buffer <strong>pH</strong> 7<br />
Mechanical connection<br />
S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />
cable<br />
Electrical connection<br />
2 or 6 pole connection<br />
Temperature sensor<br />
none, Pt100, Pt1000<br />
51
Zirkon <strong>pH</strong> coating<br />
Sensors<br />
Mechanical drawing<br />
S8 screw plug<br />
206051320 hole<br />
52
Zirkon <strong>pH</strong> coating<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
53
Zirkon <strong>pH</strong> coating<br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24132320K 206051320 <strong>pH</strong> sensor: 3M KCl, 160 mm, ceramic junction (15 mm projecting), S7<br />
plug, follow-up of S-300-K-1-5<br />
54
Zirkon <strong>pH</strong> Pool<br />
Sensors<br />
Zirkon <strong>pH</strong> Pool<br />
Low maintenance<br />
Higher life expectancy by KCl reservoir<br />
Applications<br />
Swimming-Pool<br />
Description<br />
207013100 207013110<br />
Zirkon <strong>pH</strong> Pool sensors are electrodes for <strong>pH</strong> measurement in swimming pool applications. The sensor is gel filled<br />
with salt reservoir, not refillable and requires little maintenance. The 1 mm junction and the saltreservoir increase the<br />
expected life time.<br />
55
Zirkon <strong>pH</strong> Pool<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
0.00.. 14.00 <strong>pH</strong><br />
Ambient conditions<br />
Max. pressure 2 bar at 20°C<br />
Min. condutctivity<br />
> 150 µS/cm<br />
Temperature -5.. +70 °C<br />
Mechanical construction<br />
Junction<br />
Ceramic 1mm<br />
Shaft material<br />
Glass<br />
Mechanical Construction<br />
80 mm, 120 mm<br />
Electrode material<br />
AH glass ball<br />
Reference system<br />
Ag/AgCl/saturated KCl<br />
Internal buffer <strong>pH</strong> 7<br />
Mechanical connection<br />
S8 plug (PG 13,5), fixed cable<br />
Electrical connection<br />
2 pole connection<br />
Temperature sensor<br />
none<br />
Mechanical drawing<br />
207013100<br />
56
Zirkon <strong>pH</strong> Pool<br />
Sensors<br />
207013110<br />
57
Zirkon <strong>pH</strong> Pool<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
58
Zirkon <strong>pH</strong> Pool<br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24132700K 207013100 <strong>pH</strong> sensor: saturated KCl, 120 mm, ceramic junction, S8 screw plug,<br />
follow-up of AH-300-K-6-1-PG<br />
Assembly version<br />
Article number type/configuration Description<br />
24132730K 207013110 <strong>pH</strong> sensor: saturated KCl, 80 mm, ceramic junction, S8 screw plug,<br />
follow up of AH-308-K-6-1-PG<br />
59
Zirkon Rx<br />
Sensors<br />
Zirkon Rx<br />
Low maintenance by gel filling<br />
Made in Germany<br />
Applications<br />
Waste Water Treatment<br />
Disinfection<br />
Process Water<br />
211512100 211512320 211312100<br />
Description<br />
The <strong>ORP</strong> sensors Zirkon Rx allow <strong>ORP</strong> measurements in almost every kind of medium. They require little<br />
maintenance by the gel filling and the electrode assembly or the big electrode surface.<br />
60
Zirkon Rx<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>ORP</strong><br />
-1500.. +1500 mV<br />
Ambient conditions<br />
Max. pressure 2 bar at 20°C<br />
Min. condutctivity<br />
> 150 µS/cm<br />
Temperature -5.. +70 °C<br />
plug PG PG 13,5 loose<br />
Pressure < 2 bar at 20°C < 1 bar pressureless<br />
Mechanical construction<br />
Junction<br />
Shaft material<br />
Mechanical Construction<br />
Electrode material<br />
Reference system<br />
Mechanical connection<br />
Electrical connection<br />
Ceramic 1 mm<br />
Glass<br />
120 mm, 160 mm<br />
platinum ring, platinum plate, gold ring<br />
Ag/AgCl/Tepox gel<br />
S8 plug (PG 13,5), S7 plug, fixed cable<br />
2 pole connection<br />
61
Zirkon Rx<br />
Sensors<br />
Mechanical drawing<br />
S7 plug<br />
211312100<br />
211512320<br />
62
Zirkon Rx<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
63
Zirkon Rx<br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24135110K 211512320 <strong>ORP</strong> sensor: gold ring Tepox gel, ceramic junction, S7 plug, follow-up<br />
of Au-600-O-2-1<br />
24135120K 211512100 <strong>ORP</strong>sensor: gold ring Tepox gel, ceramic junction, S8 plug (PG 13,5),<br />
follow-up of Au-600-O-2-1-PG<br />
24135210K 211312320 <strong>ORP</strong> sensor: platinum cap, Tepox gel, ceramic junction, S7 plug,<br />
follow-up of Pt-600-O-2-1<br />
24135220K 211312100 <strong>ORP</strong> sensor: platinum cap, Tepox gel, ceramic junction, S8 plug (PG<br />
13,5), follow-up of Pt-600-O-2-1-PG<br />
64
Zirkon Rx process<br />
Sensors<br />
Zirkon Rx process<br />
Usable for aggressive media<br />
Low maintenance by gel filling<br />
Made in Germany<br />
Applications<br />
Waste Water Treatment<br />
Disinfection<br />
Process Water<br />
213512210<br />
Description<br />
The Zirkon Rx process sensors are have special chemical reistant materials meant for aggressive media. The<br />
sensors are equipped with gold or platinum rings for <strong>ORP</strong> measurement. The sensors are gel filled, non-refillable<br />
and require little maintenance.<br />
65
Zirkon Rx process<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>ORP</strong><br />
-1500.. +1500 mV<br />
Ambient conditions<br />
Max. pressure 2 bar at 20°C<br />
Min. condutctivity<br />
> 150 µS/cm<br />
Temperature -5.. +70 °C<br />
plug PG PG 13,5 loose<br />
Pressure < 2 bar at 20°C < 1 bar pressureless<br />
Mechanical construction<br />
Junction<br />
Shaft material<br />
Mechanical Construction<br />
Electrode material<br />
Reference system<br />
Mechanical connection<br />
Electrical connection<br />
ceramic 1 mm, zircon, platinum, PTFE, Loch<br />
Glass<br />
80 mm, 120 mm, 160 mm<br />
platinum ring, platinum plate, gold and platinum ring, gold ring<br />
Ag/AgCl/Tepox gel Ag/AgCl/ solid electrolyt<br />
S8 plug (PG 13,5), S8 plug for aggressive media, S7 plug, fixed cable<br />
2 pole connection<br />
66
Zirkon Rx process<br />
Sensors<br />
Mechanical drawing<br />
213512210<br />
67
Zirkon Rx process<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
68
Zirkon Rx process<br />
Sensors<br />
Assembly version<br />
Article number type/configuration Description<br />
24135135K 213512210 <strong>ORP</strong> sensor: gold ring, Tepox gel, 80 mm, ceramic junction, S8 plug<br />
PBT/30%GF, follow-up of Au-658-O-2-1-PG<br />
24134030K 213400320 <strong>ORP</strong> sensor: gold- and platinum ring, S7 plug, 160 mm, follow-up of<br />
AuPt-500-OO<br />
24135170K 213372100 <strong>ORP</strong> sensor: platinum cap, Tepox gel, 120 mm, ceramic junction, S8<br />
plug (PG 13,5), follow-up of Pt-600-O-2-7-PG<br />
69
Zirkon Rx process refill<br />
Sensors<br />
Zirkon Rx process refill<br />
Long life time by refillable reference electrode<br />
Broad temperature range<br />
Made in Germany<br />
Applications<br />
Waste Water Treatment<br />
Cooling water<br />
Process Water<br />
Description<br />
214311320<br />
Zirkon Rx process refill are refillable sensors for <strong>ORP</strong> measurement. The sensors have a high blocking resistance<br />
and are usable over a broad temperature range in nearly any kind of process water.<br />
70
Zirkon Rx process refill<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>ORP</strong><br />
-1500.. +1500 mV<br />
Ambient conditions<br />
Max. pressure<br />
< 1 bar drucklos<br />
Temperature -5.. +100 °C<br />
plug PG PG 13,5 loose<br />
Pressure < 2 bar at 20°C < 1 bar pressureless<br />
Mechanical construction<br />
Junction<br />
Shaft material<br />
Mechanical Construction<br />
Electrode material<br />
Reference system<br />
Mechanical connection<br />
Electrical connection<br />
ceramic, platinum<br />
Glass<br />
80 mm, 120 mm, 160 mm<br />
platinum ring, platinum plate, gold and platinum ring, platinum ring<br />
Ag/AgCl/3M KCl<br />
S7 plug, fixed cable<br />
2-pole connection<br />
71
Zirkon Rx process refill<br />
Sensors<br />
Mechanical drawing<br />
214311320<br />
72
Zirkon Rx process refill<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
73
Zirkon Rx process refill<br />
Sensors<br />
Assembly version<br />
Article number type/configuration Description<br />
24135200K 214311320 <strong>ORP</strong> sensor: platinum plate, 3M KCl liquid refillable, 160 mm, S7 plug<br />
with hose connection, ceramic junction, follow-up model of Pt-600-O-1-1<br />
74
Zirkon Rx process refill<br />
Sensors<br />
Accessories<br />
accessories<br />
KCl vessel set<br />
Vessel-set for KCl liquid-filled <strong>pH</strong> or <strong>ORP</strong> sensors.<br />
The installation is possible on a wall or in the<br />
immersion assembly GE 23/3.<br />
Service-Set GE<br />
PG screw for sensors with 12 mm diameter. This<br />
screw enables the installation of liquid-filled sensors<br />
in the immersion assembly GE 23/3 or in the flow<br />
assembly GD (1) VG and GD (3) VG.<br />
75
Zirkon Rx Pool<br />
Sensors<br />
Zirkon Rx Pool<br />
Low maintenance<br />
Higher life expectancy by KCl reservoir<br />
Made in Germany<br />
Applications<br />
Swimming-Pool<br />
Description<br />
217313100 217300100<br />
Zirkon Rx Pool sensors are sensors for <strong>ORP</strong> measurement in swimming pool applications. The sensors are gel filled<br />
with salt reservoir, not refillable and require little maintenance. The 1 mm junction and the salt reservoir increase the<br />
expected life time.<br />
76
Zirkon Rx Pool<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
<strong>ORP</strong><br />
-1500.. +1500 mV<br />
Ambient conditions<br />
Max. pressure 2 bar at 20°C<br />
Min. condutctivity<br />
> 150 µS/cm<br />
Temperature -5.. +70 °C<br />
Mechanical construction<br />
Junction<br />
Shaft material<br />
Mechanical Construction<br />
Electrode material<br />
Reference system<br />
Mechanical connection<br />
Electrical connection<br />
none, ceramic 1mm<br />
glass<br />
120 mm<br />
platinum plate<br />
None, Ag/AgCl/KCl saturated<br />
S8 plug (PG 13,5), fixed cable<br />
2-pole screw connection<br />
Mechanical drawing<br />
217313100<br />
77
Zirkon Rx Pool<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
78
Zirkon Rx Pool<br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24135285K 217313100 <strong>ORP</strong> sensor: platinum plate, KCl saturated, ceramic junction, S8 plug<br />
(PG 13,5), follow-up of Pt-600-P-6-1-PG<br />
24134010K 217300100 <strong>ORP</strong> electrode: platinum plate, S8 plug (PG 13,5), follow-up of<br />
Pt-500-P-PG<br />
79
Zirkon REF<br />
Sensors<br />
Zirkon REF<br />
Low maintenance by gel filling<br />
Made in Germany<br />
Applications<br />
Waste Water Treatment<br />
Cooling water<br />
Process Water<br />
224B12100<br />
221B12320<br />
Description<br />
Zirkon Ref are reference electrodes. They are used as reference point for other electrodes with relative potentials<br />
e.g. in <strong>pH</strong> or <strong>ORP</strong> measurement. The gel filled sensors need lower maintenance and are used in standard<br />
application.<br />
80
Zirkon REF<br />
Sensors<br />
Ambient conditions<br />
Max. pressure<br />
0.. 2 bar<br />
Min. condutctivity<br />
> 150 µS/cm<br />
Temperature -5.. +70 °C<br />
plug PG PG 13,5 loose<br />
Pressure < 2 bar at 20°C < 1 bar pressureless<br />
Mechanical construction<br />
Junction<br />
Shaft material<br />
Mechanical Construction<br />
Reference system<br />
Mechanical connection<br />
Electrical connection<br />
ceramic 1mm, platinum<br />
Glass<br />
120 mm, 160 mm, 240 mm<br />
Tepox gel<br />
S8 plug (PG 13,5), S7 plug, fixed cable<br />
2 pole connection<br />
Mechanical drawing<br />
S8 (PG 13,5)<br />
221B12320<br />
81
Zirkon REF<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
82
Zirkon REF<br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24133100K 221B12320 reference electrode: Tepox gel, 160 mm, 1 mm ceramic junction, S7<br />
plug, follow-up of B-400-B-2-1<br />
24133110K 221B22100 reference electrode: Tepox gel, 120 mm, 1 mm ceramic junction, S8<br />
(PG 13,5) plug, follow-up of B-400-B-2-1-PG<br />
Assembly version<br />
Article number type/configuration Description<br />
24133140K 221B32320 reference electrode: Tepox gel, 160 mm, platinum junction, S7 plug,<br />
follow-up of B-400-B-2-3<br />
83
Zirkon REF<br />
Sensors<br />
Accessories<br />
sensors<br />
AH-200-K<br />
The <strong>pH</strong> electrode AH-200-K is a single measuring<br />
electrode. To measure <strong>pH</strong>, it has to be used in<br />
combination with a separate reference electrode.<br />
Combination electrodes with integrated reference are<br />
easier to calibrate and to install, but in very<br />
aggressive solutions that shorten the life time of either<br />
the reference or the measuring electrode, it might still<br />
be advantageous to use separate measuring and<br />
reference electrodes.<br />
84
Zirkon REF process refill<br />
Sensors<br />
Zirkon REF process refill<br />
Long life time by refill<br />
Sensor protection via electrolyte bridge<br />
Made in Germany<br />
Applications<br />
Process Water<br />
Waste Water Treatment<br />
Ultra Pure Water<br />
224B11320 224E10000 224E30001<br />
Description<br />
Zirkon Ref refill are refillable reference electrodes. They are used as a reference point for other electrodes with<br />
relative potentials e.g. in <strong>pH</strong> or <strong>ORP</strong> measurements. The liquid filled sensor is mainly used in waste water. For highly<br />
polluted measuring media the electrolyte bridges are recommended, because the reference electrode will not be in<br />
contact with the measuring media.<br />
85
Zirkon REF process refill<br />
Sensors<br />
Ambient conditions<br />
Max. pressure<br />
1 bar pressureless<br />
Min. condutctivity<br />
> 50 µS/cm<br />
Temperature -5.. +100 °C<br />
platinum junction Keramikdiaphragma<br />
Condutctivity < 50 µS/cm > 50 µS/cm<br />
Mechanical construction<br />
Junction<br />
Shaft material<br />
Mechanical Construction<br />
Reference system<br />
Mechanical connection<br />
Electrical connection<br />
ceramic 1 mm, platinum<br />
Glass<br />
160 mm, 180 mm<br />
none, 3M KCl liquid<br />
none, S7 plug<br />
none, 2 pole connection<br />
Mechanical drawing<br />
224B11320<br />
86
Zirkon REF process refill<br />
Sensors<br />
224E10000<br />
224E30001<br />
87
Zirkon REF process refill<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
88
Zirkon REF process refill<br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24133800K 224E10000 electrolyte bridge: 1 mm ceramic junction, follow-up of EB-400-B-1x1<br />
24133830K 224E30001 electrolyte bridge: 2 x platinum junction, follow-up of EB-400-B-2x3<br />
24133000K 224B11320 reference electrode: 3M KCl liquid, ceramic junction, follow-up of<br />
B-400-B-1-1<br />
89
Zirkon T<br />
Sensors<br />
Zirkon T<br />
Fast response - t90 = 15 sec<br />
Chemical resistant<br />
Pt100 and Pt1000 available<br />
Applications<br />
Laboratory<br />
<strong>Dr</strong>inking Water /<br />
Beverages<br />
Process Water<br />
271100100 / 271200100<br />
Description<br />
Zirkon T are high quality temperature sensors based on the resistance change of platinum wire as a function of<br />
temperature. They are specially designed to give fast response, with a t90 of 15 seconds.<br />
90
Zirkon T<br />
Sensors<br />
Technical data<br />
Measuring parameter<br />
Temperature -20.0.. +130.0 °C<br />
Ambient conditions<br />
Max. pressure < 16 bar at 20°C<br />
Mechanical construction<br />
Shaft material<br />
glass<br />
Mechanical Construction<br />
80 mm, 120 mm, 160 mm, 240 mm, special length<br />
Mechanical connection<br />
S8 plug (PG 13,5), S7 plug, SP6 plug<br />
Electrical connection<br />
2 pole screw connection; 6 pole screw connection (SP plug)<br />
Temperature sensor Pt 100; Pt 1000<br />
Mechanical drawing<br />
Sixplug<br />
271100100<br />
91
Zirkon T<br />
Sensors<br />
Order information<br />
If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />
technically inspect and approve a free combination of individual key features.<br />
92
Zirkon T<br />
Sensors<br />
Storage version<br />
Article number type/configuration Description<br />
24137011K 271100100 Temperature sensor: Pt 100, 120 mm, S8 plug<br />
24137012K 271200100 Temperature sensor: Pt 1000, 120 mm, S8 plug<br />
Assembly version<br />
Article number type/configuration Description<br />
24137013K 271100600 Temperature sensor: Pt 100, 120 mm, Sixplug<br />
24137014K 271200600 Temperature sensor: Pt 1000, 120 mm, Sixplug<br />
93
GD 1 V(G) (PP)<br />
Assemblies<br />
GD 1 V(G) (PP)<br />
Easy to dismantle<br />
Ideal for sensors with thread PG 13,5<br />
Easy mounting by bonding or 1'' female thread<br />
GD 1 VG<br />
Description<br />
Flow assembly for installation of one <strong>pH</strong> or <strong>ORP</strong> sensor in pipes with adhesive coupling or pipe coupling DN 25 with<br />
1" female thread. Available in PVC and PP.<br />
Technical data<br />
Ambient conditions<br />
Max. pressure<br />
Temperature<br />
PVC: 16 bar (at 20°C) PP: 10 bar (at 20°C)<br />
max 40 °C (PVC) max. 90 °C (PP)<br />
Mechanical construction<br />
Material<br />
PVC, PP<br />
Dimensions<br />
see dimension drawing<br />
Installation GD 1 V: adhesive coupling GD 1 VG (PP): pipe coupling DN 25 with 1"<br />
female thread<br />
94
GD 1 V(G) (PP)<br />
Assemblies<br />
Mechanical drawing<br />
GD 1 V(G)<br />
product variants<br />
Article number type/configuration Description<br />
36604261K GD 1 V adhesive coupling (DN 25), PVC<br />
36604263K GD 1 VG pipe coupling (DN 25) with 1'' internal thread, PVC<br />
36604265K GD 1 VG PP pipe coupling (DN 25) with 1'' internal thread, PP<br />
95
GD 43<br />
Assemblies<br />
GD 43<br />
Easy to dismantle<br />
Ideal for sensors with S8 screw plug-in (PG 13,5)<br />
Transparent<br />
GD 43<br />
Description<br />
Flow assembly for installation of max 3 sensors(e.g. <strong>pH</strong> and/ or <strong>ORP</strong> electrodes and temperature sensors) in pipes.<br />
Particular characteristics<br />
Easy to dismantle<br />
Ideal for sensors with S8 screw plug-in (PG 13,5)<br />
Transparent<br />
Technical data<br />
Ambient conditions<br />
Max. pressure<br />
6 bar (at 20°C)<br />
Temperature max. 60 °C<br />
Mechanical construction<br />
Material<br />
Dimensions<br />
Installation<br />
PP, Makrolon<br />
see dimension drawing<br />
Fittings 6/8 mm hoses or pipes<br />
96
GD 43<br />
Assemblies<br />
Mechanical drawing<br />
GD 43<br />
product variants<br />
Article number type/configuration Description<br />
36601171K GD 43 for max. 3 sensors<br />
97
GE 251 PP<br />
Assemblies<br />
GE 251 PP<br />
With protective cage to protect the sensor<br />
Fitting head with cable gland<br />
Easy access to sensor<br />
Fastening with pipe clamps<br />
GE 251<br />
Description<br />
Immersion assembly for installation of one <strong>pH</strong> or <strong>ORP</strong> sensor<br />
Technical data<br />
Ambient conditions<br />
Temperature max. 90 °C<br />
Mechanical construction<br />
Material<br />
Dimensions<br />
PP<br />
see dimensional drawing<br />
98
GE 251 PP<br />
Assemblies<br />
Mechanical drawing<br />
GE 251 PP<br />
product variants<br />
Article number type/configuration Description<br />
36511020K GE 251 PP immersion assembly for one <strong>pH</strong> or <strong>ORP</strong> sensor<br />
99
GE 251 PP<br />
Assemblies<br />
Accessories<br />
accessories<br />
Moisture cap<br />
Moisture cap for GE 23/3 PP For a longer period <strong>pH</strong>and<br />
<strong>ORP</strong> sensor shouldn´t dry, the moistuire cap<br />
avoid this.<br />
100
GE 23/3 PP<br />
Assemblies<br />
GE 23/3 PP<br />
Protection of the sensors by protective cage<br />
Easy fastening by pipe clamps or angle braket<br />
Installation set for KCl-vessel available<br />
GE 23/3 PP<br />
Description<br />
Immersion assembly for max. 3 sensors (<strong>pH</strong>, <strong>ORP</strong> and/or temperature sensors) in tanks or basins.<br />
Technical data<br />
Ambient conditions<br />
Temperature max. 90°C<br />
Mechanical construction<br />
Material<br />
Dimensions<br />
PP<br />
see dimension drawing<br />
101
GE 23/3 PP<br />
Assemblies<br />
Mechanical drawing<br />
GE 23/3 PP<br />
product variants<br />
Article number type/configuration Description<br />
36510012K GE 23/3 PP for max. 3 sensors, PP<br />
102
GE 23/3 PP<br />
Assemblies<br />
Accessories<br />
accessories<br />
Moisture cap<br />
Moisture cap for GE 23/3 PP For a longer period <strong>pH</strong>and<br />
<strong>ORP</strong> sensor shouldn´t dry, the moistuire cap<br />
avoid this.<br />
MW/MD GE 23/3<br />
PP<br />
Angle braket for the immersion assembly GE 23/3<br />
VA-Pole for<br />
KCl-vessel<br />
For installation of KCl vessel in flow assembly GE<br />
23/3<br />
KCl vessel set<br />
Vessel-set for KCl liquid-filled <strong>pH</strong> or <strong>ORP</strong> sensors.<br />
The installation is possible on a wall or in the<br />
immersion assembly GE 23/3.<br />
Service-Set GE<br />
PG screw for sensors with 12 mm diameter. This<br />
screw enables the installation of liquid-filled sensors<br />
in the immersion assembly GE 23/3 or in the flow<br />
assembly GD (1) VG and GD (3) VG.<br />
103
PM 6<br />
Handheld Units<br />
PM 6<br />
Automatic or manual temperature compensation<br />
Test of electrode quality<br />
Min/ max value memory, hold function<br />
PM 6 Set<br />
Description<br />
All-purpose portable measuring instrument for measurement of <strong>pH</strong>, <strong>ORP</strong> and temperature. Connection of <strong>pH</strong> and<br />
<strong>ORP</strong> combination electrodes with and without Pt 100 is possible. Handheld instrument, sensor and <strong>pH</strong> 4 and <strong>pH</strong> 7<br />
buffer solution each 50 mL in a portable case are included in delivery.<br />
Particular characteristics<br />
Automatic or manual temperature compensation<br />
Automatic power shut-off<br />
Double display for measured value and temperature<br />
Power supply by battery or rechargeable<br />
Easy and safe handling by 6 soft keys<br />
Low battery indication<br />
With fold away support<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
0.. 14 <strong>pH</strong><br />
<strong>ORP</strong><br />
-1999.. +1999 mV<br />
Temperature -100.. +250 °C<br />
104
PM 6<br />
Handheld Units<br />
Power supply<br />
Line voltage<br />
Power supply<br />
Power consumption<br />
via 10-12 V (power unit not included in delivery)<br />
9V battery<br />
ca. 3 mA<br />
Ambient conditions<br />
Ambient temperature operation 0 .. 50°C storage -20° .. 70°C<br />
Relative humidity<br />
max. 90% rH at 40°C (non-condensing)<br />
Protection class IP 65<br />
Connections<br />
Sensor<br />
BNC plug (<strong>pH</strong>/<strong>ORP</strong>) female mini DIN plug (T)<br />
Certificates and approvals<br />
CE-Symbol<br />
Declaration of conformity: The product meets the requirements of the<br />
harmonized European standards. It thus complies with the legal requirements<br />
of the EC directives. The manufacturer confirms successful testing of the<br />
product by affixing the CE symbol.<br />
product variants<br />
Article number type/configuration Description<br />
65512510K PM 6 complete set measuring instrument with sensor (Zirkon <strong>pH</strong> 201012103),<br />
cable and each 50 ml buffer solution <strong>pH</strong> 4 and <strong>pH</strong> 7 including portable<br />
case<br />
105
PM 6<br />
Handheld Units<br />
Accessories<br />
accessories<br />
COAX-D-2-1,5<br />
Coaxial cable with sensor and BNC plug, length 1,5 m<br />
<strong>pH</strong> buffer solutions<br />
The slope of <strong>pH</strong> sensors changes over the time<br />
(depending on the measuring media). We recomment<br />
a regular calibration with our buffer solutions. We offer<br />
1000 ml packages of <strong>pH</strong> 2, <strong>pH</strong> 3,56, <strong>pH</strong> 4, <strong>pH</strong> 7, and<br />
<strong>pH</strong> 9,22, and 50 ml packages of <strong>pH</strong> 4, and <strong>pH</strong> 7.<br />
106
PH-T<br />
Handheld Units<br />
PH-T<br />
Testing of <strong>pH</strong>- and <strong>ORP</strong> sensors<br />
Testing of <strong>pH</strong> and <strong>ORP</strong> instruments and cables<br />
PH-T Set<br />
Description<br />
<strong>pH</strong> and mV simulator to check <strong>pH</strong> and <strong>ORP</strong> measuring instruments and electrodes. Complete set: simulator with<br />
cable and adapter in a portable case.<br />
Particular characteristics<br />
High-impedance test (>1000MOhm)<br />
Voltage measurement in mV<br />
Presetting of voltage in mV or <strong>pH</strong><br />
Power supply or rechargeable<br />
Technical data<br />
Measuring parameter<br />
<strong>ORP</strong><br />
-1500.. +1500 mV<br />
Input characteristics<br />
Accuracy<br />
+/- 1 mV<br />
Output characteristics<br />
Voltage presetting<br />
Ph-simulation<br />
-1500 .. +1500 mV<br />
0 .. 14 <strong>pH</strong><br />
107
PH-T<br />
Handheld Units<br />
Power supply<br />
Line voltage<br />
Power supply<br />
Ladestrom<br />
input voltage about 15-16 V, barrel connector AD 5 mm, ID 2mm<br />
9 V battery or 9 V rechargeable battery<br />
18 - 20 mA<br />
Ambient conditions<br />
Ambient temperature operation 0 .. +40 °C storage -20 .. +65 °C<br />
Relative humidity<br />
max. 90% rF at 40°C (non-condensing)<br />
Protection class IP 40<br />
Connections<br />
Sensor<br />
BNC plug<br />
Certificates and approvals<br />
CE-Symbol<br />
Declaration of conformity: The product meets the requirements of the<br />
harmonized European standards. It thus complies with the legal requirements<br />
of the EC directives. The manufacturer confirms successful testing of the<br />
product by affixing the CE symbol.<br />
product variants<br />
Article number type/configuration Description<br />
45512800K PH-T complete set: simulator with caable and adapter incl portable case<br />
108
PH-T<br />
Handheld Units<br />
Accessories<br />
accessories<br />
COAX-D-2-1,5<br />
Coaxial cable with sensor and BNC plug, length 1,5 m<br />
109
S-341 data logger<br />
Accessories<br />
S-341 data logger<br />
Free administration of 10 instruments with up to 8 parameter each<br />
Data storing takes place up to every second<br />
S-341 data logger<br />
Description<br />
The bus data logger S-341 on the base of the RS-485 with <strong>Kuntze</strong> protocol reads, shows, and stores measuring<br />
data of up to 10 <strong>Kuntze</strong> instruments with up to 8 parameters each.<br />
Particular characteristics<br />
available in German, English or French menu guidance<br />
data storing in 24h files in text format<br />
storage media is standard SD-card (max. 1 GB, FAT 12/16)<br />
Graphical program vario view2 is available free of charge<br />
Technical data<br />
Power supply<br />
Voltage supply<br />
20...253 VDC or 50...253 VAC<br />
Ambient conditions<br />
Ambient temperature<br />
panel mounted housing (91x44x131)<br />
110
S-341 data logger<br />
Accessories<br />
Mechanical construction<br />
Installation dimensions<br />
panel mounted housing (91x44x131)<br />
product variants<br />
Article number type/configuration Description<br />
42001000K S-341 data logger bus data logger based on RS 485 with <strong>Kuntze</strong> protocol<br />
111
COAX-D-AE-X<br />
Accessories<br />
COAX-D-AE-X<br />
Low-noise<br />
Singled screened<br />
Electrode connector<br />
Wire end ferrules<br />
Integrated semiconductor layer for antistatic protection<br />
Description<br />
Single screened cable for connecting <strong>pH</strong>- and <strong>ORP</strong> sensors, available in 3, 5 and 10.<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
0.. 14 <strong>pH</strong><br />
Ambient conditions<br />
Ambient temperature -20 .. + 70°C<br />
Mechanical construction<br />
Material<br />
PVC<br />
112
COAX-D-AE-X<br />
Accessories<br />
product variants<br />
Article number type/configuration Description<br />
44136007K COAX-D-AE-3 connection cable for <strong>pH</strong> and <strong>ORP</strong> sensors, 3 m<br />
44136009K COAX-D-AE-5 connection cable for <strong>pH</strong> and <strong>ORP</strong> sensors, 5 m<br />
44136011K CoAX-D-AE-10 connection cable for <strong>pH</strong> and <strong>ORP</strong> sensors, 10 m<br />
113
TRIAX-D-1-X<br />
Accessories<br />
TRIAX-D-1-X<br />
Low-noise<br />
Dual screened<br />
Electrode connector<br />
Integrated semiconductor layer for antistatic protection<br />
Description<br />
Dual screened cable for connecting <strong>pH</strong> sensors, available in 3 and 5 m.<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
0.. 14 <strong>pH</strong><br />
Ambient conditions<br />
Ambient temperature -20 .. + 70°C<br />
Mechanical construction<br />
Material<br />
PVC<br />
product variants<br />
Article number type/configuration Description<br />
44136120K TRIAX-D-1-3 double screened connection cable for <strong>pH</strong> sensors, 3 m<br />
44136125K TRIAX-D-1-5 double screened connection cable for <strong>pH</strong> sensors, 5 m<br />
114
IWA 11.4<br />
Accessories<br />
IWA 11.4<br />
converts the high-impedance signal into a less sensitive low-impedance signal<br />
Connection between IWA and measuring instrument is possible with standard cable (up to<br />
1000 m length)<br />
Screened PVC housing<br />
Applications<br />
Waste Water Treatment<br />
Process Water<br />
<strong>Dr</strong>inking Water /<br />
Beverages<br />
Food Industry<br />
IWA 11.4<br />
Description<br />
Impedance converter - for longer distances between electrode and measuring instrument or under unfavourable<br />
installation conditions.<br />
Technical data<br />
Input characteristics<br />
Input resistor<br />
10^12 Ohm<br />
Output characteristics<br />
Output resistor<br />
1 kOhm<br />
Power supply<br />
Voltage supply<br />
+/- 5 .. 15 V<br />
115
IWA 11.4<br />
Accessories<br />
Ambient conditions<br />
Ambient temperature max. 50°C<br />
product variants<br />
Article number type/configuration Description<br />
47890101K IWA 11.4 impedance converter<br />
116
2CORE-D-1-X<br />
Accessories<br />
2CORE-D-1-X<br />
Low cable capacitance<br />
Screened<br />
Electrode connector<br />
Description<br />
Cable for connecting temperature sensors, available in 3, 5 and 10 m.<br />
Technical data<br />
Measuring parameter<br />
<strong>pH</strong>-value<br />
0.. 14 <strong>pH</strong><br />
Ambient conditions<br />
Ambient temperature -20 .. + 70°C<br />
Mechanical construction<br />
Material<br />
PVC<br />
product variants<br />
Article number type/configuration Description<br />
44136071K 2CORE-D-1-3 connection cable for Pt 100 sensors, 3 m<br />
44136066K 2CORE-D-1-5 connection cable for Pt 100 sensors, 5 m<br />
44136081K 2CORE-D-1-10 connection cable for Pt 100 sensors, 10 m<br />
117
<strong>pH</strong> buffer solutions<br />
Accessories<br />
<strong>pH</strong> buffer solutions<br />
For calibration of <strong>pH</strong> sensors<br />
<strong>pH</strong>-buffer solution<br />
Description<br />
The slope of <strong>pH</strong> sensors changes over the time (depending on the measuring media). We recomment a regular<br />
calibration with our buffer solutions. We offer 1000 ml packages of <strong>pH</strong> 2, <strong>pH</strong> 3,56, <strong>pH</strong> 4, <strong>pH</strong> 7, and <strong>pH</strong> 9,22, and 50<br />
ml packages of <strong>pH</strong> 4, and <strong>pH</strong> 7.<br />
product variants<br />
Article number type/configuration Description<br />
95212000K <strong>pH</strong> 2 - cal 1000 ml buffer solution <strong>pH</strong> 2<br />
95212003K <strong>pH</strong> 3,56 - cal 1000 ml buffer solution <strong>pH</strong> 3,56<br />
95212007K <strong>pH</strong> 4 - cal 1000 ml buffer solution <strong>pH</strong> 4<br />
95212010K <strong>pH</strong> 4 - cal 50 ml buffer solution <strong>pH</strong> 4<br />
95212001K <strong>pH</strong> 7 - cal 1000 ml buffer solution <strong>pH</strong> 7<br />
95212009K <strong>pH</strong> 7 - cal 50 ml buffer solution <strong>pH</strong> 7<br />
95212004K <strong>pH</strong> 9,22 -cal 1000 ml buffer solution <strong>pH</strong> 9,22<br />
118
The <strong>Dr</strong>. A. <strong>Kuntze</strong> <strong>GmbH</strong> "Terms and Conditions" will be applicable.<br />
<strong>pH</strong>/ <strong>ORP</strong><br />
Notes
Powered by TCPDF (www.tcpdf.org)<br />
<strong>Dr</strong>. A. <strong>Kuntze</strong> <strong>GmbH</strong><br />
Robert-Bosch-Str. 7a | D-40668 Meerbusch | Germany<br />
Fon +49 (0) 2150 70 66 -0 | Fax +49 (0) 2150 70 66 -60<br />
info@kuntze.com | www.kuntze.com