20.01.2015 Views

pH / ORP - Dr. A. Kuntze GmbH

pH / ORP - Dr. A. Kuntze GmbH

pH / ORP - Dr. A. Kuntze GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DR. A. <strong>Kuntze</strong><br />

product catalogue 2013<br />

<strong>pH</strong>/ <strong>ORP</strong><br />

valid from 01.01.2013<br />

subject to alterations


<strong>pH</strong>/ <strong>ORP</strong><br />

Contents<br />

Systems ....................................................................................................................................... 4<br />

BalanceCon ................................................................................................................................ 4<br />

Instruments .................................................................................................................................. 9<br />

Neon pR ..................................................................................................................................... 9<br />

K 100 (W) PR ............................................................................................................................ 17<br />

Sensors ...................................................................................................................................... 23<br />

Zirkon <strong>pH</strong> .................................................................................................................................. 23<br />

Zirkon <strong>pH</strong> process ..................................................................................................................... 28<br />

Zirkon <strong>pH</strong> fluoride ...................................................................................................................... 33<br />

Zirkon <strong>pH</strong> process refill ............................................................................................................... 38<br />

Zirkon <strong>pH</strong> pure .......................................................................................................................... 44<br />

Zirkon <strong>pH</strong> coating ...................................................................................................................... 50<br />

Zirkon <strong>pH</strong> Pool .......................................................................................................................... 55<br />

Zirkon Rx .................................................................................................................................. 60<br />

Zirkon Rx process ...................................................................................................................... 65<br />

Zirkon Rx process refill ............................................................................................................... 70<br />

Zirkon Rx Pool ........................................................................................................................... 76<br />

Zirkon REF ................................................................................................................................ 80<br />

Zirkon REF process refill ............................................................................................................ 85<br />

Zirkon T .................................................................................................................................... 90<br />

Assemblies ................................................................................................................................ 94<br />

GD 1 V(G) (PP)......................................................................................................................... 94<br />

GD 43 ....................................................................................................................................... 96<br />

GE 251 PP ................................................................................................................................ 98<br />

GE 23/3 PP ............................................................................................................................. 101<br />

Handheld Units ........................................................................................................................ 104<br />

PM 6 ....................................................................................................................................... 104<br />

PH-T ....................................................................................................................................... 107<br />

Accessories ............................................................................................................................. 110<br />

S-341 data logger .................................................................................................................... 110<br />

COAX-D-AE-X ......................................................................................................................... 112<br />

TRIAX-D-1-X ........................................................................................................................... 114<br />

IWA 11.4 ................................................................................................................................. 115<br />

2CORE-D-1-X ......................................................................................................................... 117<br />

<strong>pH</strong> buffer solutions .................................................................................................................. 118


BalanceCon<br />

Systems<br />

BalanceCon<br />

High operation safety by defined reaction time in the marble filter<br />

Low maintenance by automatic zero calibration<br />

Integrated controller for optimum decarbonisation<br />

Applications<br />

<strong>Dr</strong>inking Water /<br />

Beverages<br />

Cooling water<br />

BalanceCon in a panel<br />

Description<br />

The measurement is based on the <strong>pH</strong>-difference method described in DIN 38404-10 : 1995-04 Calcit saturation of<br />

water. Automatic zero-point calibration of the <strong>pH</strong>-difference measurement. Reaction time in the marble filter<br />

controlled by stepmotor-driven peristaltic pumps Two separate controllers both of which can be assigned to the <strong>pH</strong><br />

value of the incoming water or after the marble filter or to the <strong>pH</strong> difference.<br />

Particular characteristics<br />

2 limit values with delay, assigned to alarm relay for <strong>pH</strong> value or difference<br />

2 separate PID controllers for <strong>pH</strong> value or difference<br />

Automatic zero calibration of the <strong>pH</strong> difference in adjustable time interval<br />

Semi-automatic two-point-calibration<br />

Manual or automatic temperature compensation by integrated Pt100<br />

Background illuminated four-line LC-Display for <strong>pH</strong> value and <strong>pH</strong> difference or <strong>pH</strong> value<br />

before and after marble filter or <strong>pH</strong> value and temperature<br />

4 x scaleable, galvanically isolated 0/4 .. 20 mA outputs<br />

Option: serial interface RS 485<br />

4


BalanceCon<br />

Systems<br />

Block diagram<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

0.00.. 14.00 <strong>pH</strong> measuring value 1: before the filter<br />

0.00.. 14.00 <strong>pH</strong> measuring value 2: after the filter<br />

-0.5.. +0.5 <strong>pH</strong> <strong>pH</strong> difference (measuring value 2 - measuring value 1)<br />

Input characteristics<br />

Accuracy<br />

+/- 0.02 <strong>pH</strong><br />

Temperature measuring range -30.. +140°C display range<br />

Ambient conditions Flow min. 15 l/h<br />

Min. conductivity > 150 µS/cm<br />

Temperature 0.. 50 °C<br />

5


BalanceCon<br />

Systems<br />

Output characteristics<br />

Alarm relay<br />

1 x potential-free CO-contact, max. 250 V, 6A, 550 VA for alarm<br />

Output signal<br />

4x 0/4.. 20 mA (scaleable, galvanic isolated)<br />

Load<br />

max. 500 Ohm<br />

Registration range Scaleable within the measuring range<br />

Serial interface Option: RS 485<br />

Baud rate<br />

9600 baud<br />

Data format 8 bit<br />

Power supply<br />

Line voltage<br />

Power consumption<br />

Wide range power supply 85.. 265 V AC oder DC<br />

36 VA<br />

Ambient conditions<br />

Temperature Storage -20.. +65°C, exception sensors 0..<br />

+30°C<br />

Operation 0.. 50°C<br />

Protection class Wall mounted IP 54<br />

Controller<br />

Control mode<br />

On/off controller (adjustable hysteresis) P/PI/PID-controller (pulse-pause,<br />

pulse-frequency or continous controller output)<br />

Relay<br />

2 x potential-free NO-contact, max. 250 V, 6 A, 550 VA for activation dosing<br />

pumps / Servo-motor<br />

Start delay<br />

0.. 200 sec until controller active<br />

Digital input 1) low water 2) Ext. Initiation of the automatic zero-point calibration 3)<br />

external controller stop<br />

Design configuration<br />

Material<br />

Dimensions<br />

board: PVC, assembly: PVC, cocks: PP instrument: ABS, sensors: glass<br />

550 x 545 x 150 mm<br />

6


BalanceCon<br />

Systems<br />

Mechanical drawing<br />

BalanceCon<br />

Storage version<br />

Article number type/configuration Description<br />

77612729K BalanceCon Measuring system to measure and control calcite solubility<br />

7


BalanceCon<br />

Systems<br />

Accessories<br />

accessories<br />

BalanceCon cabinet External dimensions (W x H x D): 600 x 600 x 200<br />

mm, door with integrated inspection glass made of<br />

3mm impact resistant acryl glass<br />

<strong>pH</strong> buffer solutions<br />

The slope of <strong>pH</strong> sensors changes over the time<br />

(depending on the measuring media). We recomment<br />

a regular calibration with our buffer solutions. We offer<br />

1000 ml packages of <strong>pH</strong> 2, <strong>pH</strong> 3,56, <strong>pH</strong> 4, <strong>pH</strong> 7, and<br />

<strong>pH</strong> 9,22, and 50 ml packages of <strong>pH</strong> 4, and <strong>pH</strong> 7.<br />

BalanceCon<br />

refill-set<br />

Refill-set for the filter, 600 g pellets<br />

sensors<br />

201012100 The sensor of the Zirkon <strong>pH</strong> series are highly<br />

sophisticated sensors with a high value for money<br />

ratio. They are used in many applications e.g.<br />

industrial, process and waste water. We use our high<br />

performance AH glass with low alkaline error and a<br />

broad temperature range. We use a high class<br />

ceramic junction which increases the sensor life<br />

expectancy and our low maintenance Topax gel. As<br />

reference system we use a cartridge system which<br />

results for a constant measurement especially in<br />

applications with high temperature fluctuations.<br />

8


Neon pR<br />

Instruments<br />

Neon pR<br />

Easy handling by graphical menue<br />

Fitting for your application by modular setup<br />

Comfortable by firmware update and configuration via SD card<br />

Applications<br />

Process Water<br />

<strong>Dr</strong>inking Water /<br />

Beverages<br />

Waste Water Treatment<br />

Neon Touch wall mounted housing<br />

Description<br />

Neon is a modern measuring and control instrument, whose scope of functions you can determine according to your<br />

application. The basic version contains inputs for measurement and temperature, key operation, one digital input<br />

and one alarm relay. Via codes and add-on modules you can add one or two analog outputs, control functions either<br />

concentration-based or volume-based, as well as various digital output functions such as modbus interface,<br />

Ethernet, webserver, or datalogger. You can even adjust what information you want to see in the display. And if you<br />

have to install more than one instrument of the same type with the same settings, settings can easily be multiplied<br />

via SD card. Use the full advantages of the graphical menus with our touch screen version Neon Touch! Neon pR is<br />

used for <strong>pH</strong> and <strong>ORP</strong> measurements.<br />

9


Neon pR<br />

Instruments<br />

Particular characteristics<br />

85 .. 265 V AC power supply<br />

Guided two point calibration<br />

Logging of the last 10 calibration data<br />

Automatic or manual temperature compensation<br />

2 user levels by password function<br />

Safety by autolock function<br />

Power saving adjustable<br />

Alerts selectable for alarm relay<br />

SD card function: firmware update, configuration and diagnosis file<br />

Test menu for wiring check<br />

Real time clock<br />

Eventlog and event help<br />

Functional upgrade by activation code or with modules<br />

Option: 2 mA outputs 0/4 to 20 mA adjustable with fault current<br />

Option: data log function<br />

Option: RS 485 Modbus RTU<br />

Option: Ethernet with internal webserver<br />

Option: 24 V DC<br />

Option: 2nd digital input<br />

Option: 2 PID controller with digital output<br />

Option: volume-based dosage with measurement<br />

10


Neon pR<br />

Instruments<br />

Block diagram<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

<strong>ORP</strong><br />

-2.00.. +16.00 <strong>pH</strong><br />

-1500.. +1500 mV<br />

Input characteristics<br />

Temperature measuring range -30.0 .. +140.0 °C<br />

Temperature coefficient<br />

Non-linear<br />

Digital input<br />

1 as controller stop by external contact option: 2nd as controller stop or flow<br />

measurement for volume based dosing<br />

11


Neon pR<br />

Instruments<br />

Output characteristics<br />

Alarm relay<br />

Output signal<br />

Voltage output<br />

Storage media<br />

Serial interface<br />

1 potential-free NO contact, max. 250 V, 6 A, 550 VA (invertable)<br />

Option: 2 x 0/4 .. 20 mA (scaleable, galvanically isolated)<br />

Load<br />

500 Ohm<br />

Registration range Scaleable within the measuring range<br />

+/- 6 VDC for impedance converter<br />

Accessorie: SD card up to 2 MB - industrial standard<br />

Option: RS 485 modbus RTU<br />

Baud rate<br />

19200 bps<br />

Data format 8 bit<br />

Ethernet<br />

Option: internal webserver<br />

Power supply<br />

Line voltage<br />

Power consumption<br />

85.. 250 V AC, +6/-10%, 40.. 60Hz option: 24 V DC<br />

10 VA<br />

Ambient conditions<br />

Temperature Storage -20.. +65°C<br />

Operation<br />

-5.. +50°C<br />

Humidity<br />

max. 90% rH at 40°C (non-condensing)<br />

Protection class Wall mounted IP 65<br />

Panel mounted IP 54 (front), IP 30 (housing)<br />

Controller<br />

Control response<br />

Relay<br />

Start delay<br />

Controller stop<br />

Option: on/off controller (adjustable hysteresis) P/PI/ PID controller<br />

(pulse-pause, pulse-frequency or continuous output) servo motor control<br />

2 relays, each with a potential-free NO contact, max. 250V, 6 A, 550 VA<br />

0.. 200 sec until controller active<br />

Digital input<br />

Proportion to volume<br />

Control mode<br />

Option: quantity based by flow measurement<br />

Flow measurement Impuls measurement NPN (by digital input 2)<br />

Flow measurement Engine speed 0.030.. 9.999 l/Imp<br />

Relay 1<br />

Potential-free NO contact, max. 250V, 6 A, 550 VA output of<br />

control variable as pulse frequency or pulse pause.<br />

Relay 2<br />

Activating circulation pump<br />

Certificates and approvals<br />

CE-Symbol<br />

The product meets the requirements of the harmonized European standards.<br />

It thus complies with the legal requirements of the EC directives.<br />

EMV/EMC EN 61000 6-1 (3) EN 61000 6-2 (4) EN 61326-1<br />

12


Neon pR<br />

Instruments<br />

Design configuration<br />

Material<br />

Dimensions<br />

Mounting dimension<br />

Weight<br />

Connection<br />

ABS<br />

Panel mounted housing: 138x138x83 mm; Wall mounted housing:<br />

144x144x156 mm<br />

Panel mounted housing: 138x138x42 mm<br />

0.6 kg (wall mounted housing: 1 kg)<br />

Cable inlet: 2x M16, 2x M12 + optional: 2x M12 and 1x M25 plug-in terminal:<br />

rigid /flexible 0.2-2.5 mm² / 0.2-2.5 mm² measurement rigid /flexible 0.2-1<br />

mm² / 0.2-1.5 mm²<br />

Mechanical drawing<br />

Panel mounted housing<br />

13


Neon pR<br />

Instruments<br />

Wall mounted housing<br />

14


Neon pR<br />

Instruments<br />

Order information<br />

Choose the components you need and that´s how your "assembly version" is designed. We will have to technically<br />

inspect and approve a free combination of individual key features.<br />

15


Neon pR<br />

Instruments<br />

Accessories<br />

accessories<br />

<strong>pH</strong> buffer solutions<br />

The slope of <strong>pH</strong> sensors changes over the time<br />

(depending on the measuring media). We recomment<br />

a regular calibration with our buffer solutions. We offer<br />

1000 ml packages of <strong>pH</strong> 2, <strong>pH</strong> 3,56, <strong>pH</strong> 4, <strong>pH</strong> 7, and<br />

<strong>pH</strong> 9,22, and 50 ml packages of <strong>pH</strong> 4, and <strong>pH</strong> 7.<br />

Measuring point setup<br />

16


K 100 (W) PR<br />

Instruments<br />

K 100 (W) PR<br />

Easy and save operation by plain text menu guidance<br />

Safety by password function<br />

Applications<br />

Waste Water Treatment<br />

Cooling water<br />

<strong>Dr</strong>inking Water /<br />

Beverages<br />

K 100 W PR<br />

Process Water<br />

Description<br />

The K 100 (W) PR is a sophisticated single-channel instrument for measuring and control the <strong>pH</strong>-value or the <strong>ORP</strong>.<br />

Additionaly temperature measurement of the measuring media is possible. The instrument is available in a panel<br />

mounted housing (K100 PR) and in a wall mounted housing (K 100 W PR).<br />

Particular characteristics<br />

2 limit values with delay, assigned to alarm relay<br />

2 integrated PI-controller<br />

Dosage check<br />

Semi-automatic two-point-calibration for <strong>pH</strong><br />

Slope and zero point monitoring for <strong>pH</strong><br />

Automatic or manual <strong>pH</strong>-value compensation<br />

Background illuminated two-line LC-Display for measured value and temperature<br />

Scaleable, galvanically isolated 0/4..20 mA output<br />

Display of relay and error messages<br />

Invertible alarm output, permanent or pulse contact<br />

Option: serial interface RS 485<br />

17


K 100 (W) PR<br />

Instruments<br />

Block diagram<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

<strong>ORP</strong><br />

-2.00.. +16.00 <strong>pH</strong><br />

-1500.. +1500 mV<br />

Input characteristics<br />

Temperature measuring range<br />

Digital input<br />

-30.. +140 °C (display range)<br />

1 as controller stop as external contact<br />

18


K 100 (W) PR<br />

Instruments<br />

Output characteristics<br />

Alarm relay<br />

1 potential-free NO contact, max. 250 V, 6 A, 550 VA<br />

Output signal<br />

1 x 0/4.. 20 mA (scaleable, galvanic isolated)<br />

Load<br />

max. 500 Ohm<br />

Registration range Scaleable within the measuring range<br />

Voltage output<br />

+/- 6 VDC for impedance converter<br />

Serial interface Option: RS 485<br />

Baud rate<br />

9600 baud<br />

Data format 8 bit<br />

Power supply<br />

Line voltage<br />

Power consumption<br />

24 / 117/ 230 VAC, +6/-10%, 40.. 60 Hz<br />

10 VA<br />

Ambient conditions<br />

Temperature Storage -20.. +65°C<br />

Operation 0.. 50°C<br />

Protection class Wall mounted IP 65<br />

Panel mounted IP 54 (front), IP 30 (housing)<br />

Controller<br />

Control response<br />

Relay<br />

Start delay<br />

Controller stop<br />

on/off controller (adjustable hysteresis) P/PI controller (pulse-pause,<br />

pulse-frequency or continuous output)<br />

2 relays, each with a potential-free NO contact, max. 250V, 6 A, 550 VA<br />

0.. 200 sec until controller active<br />

Digital input<br />

Certificates and approvals<br />

CE-Symbol<br />

EMV/EMC<br />

The product meets the requirements of the harmonized European standards.<br />

It thus complies with the legal requirements of the EC directives.<br />

EN 61326 Klasse B, 2004/108/EG<br />

Design configuration<br />

Material<br />

Dimensions<br />

Mounting dimension<br />

Weight<br />

Panel mounted housing: Noryl; Wall mounted hosuing: ABS<br />

Panel mounted housing: 90x90x116 mm; Wall mounted housing: 165x160x85<br />

mm<br />

Panel mounted housing: 92x92x140 mm<br />

Panel mounted housing: 0,75 kg; Wall mounted housing: 0,95 kg<br />

19


K 100 (W) PR<br />

Instruments<br />

Mechanical drawing<br />

Wall mounted housing<br />

Panel mounted housing<br />

20


K 100 (W) PR<br />

Instruments<br />

Storage version<br />

Article number type/configuration Description<br />

100000K K 100 PR <strong>pH</strong> or <strong>ORP</strong> and T single measurement, panel mounted housing, 230 V<br />

105000K K 100 W PR <strong>pH</strong> or <strong>ORP</strong> and T single measurement<br />

21


K 100 (W) PR<br />

Instruments<br />

Accessories<br />

accessories<br />

<strong>pH</strong> buffer solutions<br />

The slope of <strong>pH</strong> sensors changes over the time<br />

(depending on the measuring media). We recomment<br />

a regular calibration with our buffer solutions. We offer<br />

1000 ml packages of <strong>pH</strong> 2, <strong>pH</strong> 3,56, <strong>pH</strong> 4, <strong>pH</strong> 7, and<br />

<strong>pH</strong> 9,22, and 50 ml packages of <strong>pH</strong> 4, and <strong>pH</strong> 7.<br />

S-341 data logger The bus data logger S-341 on the base of the RS-485<br />

with <strong>Kuntze</strong> protocol reads, shows, and stores<br />

measuring data of up to 10 <strong>Kuntze</strong> instruments with<br />

up to 8 parameters each.<br />

Measuring point setup<br />

22


Zirkon <strong>pH</strong><br />

Sensors<br />

Zirkon <strong>pH</strong><br />

Low maintenance by gel filling<br />

High precision by use of high alkaline high temperature glass<br />

Made in Germany<br />

Applications<br />

Process Water<br />

<strong>Dr</strong>inking Water /<br />

Beverages<br />

Waste Water Treatment<br />

201012103 201112400 201012100<br />

Description<br />

The sensor of the Zirkon <strong>pH</strong> series are highly sophisticated sensors with a high value for money ratio. They are used<br />

in many applications e.g. industrial, process and waste water. We use our high performance AH glass with low<br />

alkaline error and a broad temperature range. We use a high class ceramic junction which increases the sensor life<br />

expectancy and our low maintenance Topax gel. As reference system we use a cartridge system which results for a<br />

constant measurement especially in applications with high temperature fluctuations.<br />

23


Zirkon <strong>pH</strong><br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

0.. 14 <strong>pH</strong><br />

Ambient conditions<br />

Max. pressure<br />

< 2 bar<br />

Min. condutctivity<br />

> 150 µS/cm<br />

Temperature -5.. +70 °C<br />

plug PG resin shaft PG 13,5 loose<br />

Pressure < 2 bar at 20°C < 1 bar at 20°C < 1 bar at 20°C<br />

Mechanical construction<br />

Junction<br />

ceramic 1 mm<br />

Shaft material<br />

glass, resin<br />

Mechanical Construction<br />

120 mm, 160 mm<br />

Electrode material<br />

AH-Glas ball<br />

Reference system<br />

Ag/AgCl/Tepox gel Ag/AgCl/Tepoxgel - saturated KCl<br />

Internal buffer <strong>pH</strong> 7<br />

Mechanical connection<br />

S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />

cable<br />

Electrical connection<br />

2 or 6 pole connection<br />

Temperature sensor<br />

none, Pt100, Pt1000<br />

24


Zirkon <strong>pH</strong><br />

Sensors<br />

Mechanical drawing<br />

S8 plug<br />

SP Sixplug<br />

201012100 resin shaft<br />

S7 plug<br />

201012320<br />

25


Zirkon <strong>pH</strong><br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

26


Zirkon <strong>pH</strong><br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24131110K 201012100 <strong>pH</strong> sensor: Tepoxgel, 120 mm, ceramic junction, S8 screw plug,<br />

follow-up of AH-300-K-2-1-PG<br />

24131100K 201012320 <strong>pH</strong> sensor: Tepoxgel, 160 mm, ceramic junction, S7 plug, follow-up of<br />

AH-300-K-2-1<br />

Assembly version<br />

Article number type/configuration Description<br />

24132650K 201012103 <strong>pH</strong> sensor: Tepox gel, 120 mm, ceramic junction, S8 screw plug,<br />

follow-up of AH-320-K-2-1-PG<br />

24132111K 201112400 <strong>pH</strong> sensor: Tepox gel, 120 mm, ceramic junction, sixplug, follow-up of<br />

AH-305-K-2-1-PG<br />

27


Zirkon <strong>pH</strong> process<br />

Sensors<br />

Zirkon <strong>pH</strong> process<br />

Low maintenance by gel or solid filling<br />

Dirt resistant by premium-quality junctions<br />

Made in Germany<br />

Applications<br />

Waste Water Treatment<br />

Process Water<br />

Cooling water<br />

203038390 203072100 203085100<br />

Description<br />

The sensors of the Zirkon <strong>pH</strong> process series are highly sophisticated sensors with a high value for money ratio. They<br />

are used in applications like process and waste water. We use our high performance AH glass with low alkaline error<br />

and a broad temperature range. We use different materials like ceramic, platinum or PTFE as junction. The junction<br />

is among other things responsible for the salt output and the dirt resistance. As electrolyte we use our low<br />

maintenance Topax gel. As reference system we use a cartridge system which results in a constant measurement<br />

even in applications with high temperature fluctuations.<br />

28


Zirkon <strong>pH</strong> process<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

0.. 14 <strong>pH</strong><br />

Ambient conditions<br />

Max. pressure 0.. 10 bar at 20°C<br />

Min. condutctivity<br />

> 150 µS/cm<br />

Temperature -5.. +70 °C<br />

PTFE Hole Ceramic Platin<br />

Pressure < 10 bar at 20 °C < 1 bar pressure less < 2 bar at 20 °C < 2 bar at 20 °C<br />

plug PG PG 13,5 loose<br />

Pressure < 10 bar at 20 °C < 1 bar at 20°C<br />

Mechanical construction<br />

Junction<br />

ceramic 1mm, zircon, platinum, PTFE, hole<br />

Shaft material<br />

Glass<br />

Mechanical Construction<br />

120 mm, 160 mm, 220 mm (double chamber), 240 mm<br />

Electrode material<br />

AH glass ball<br />

Reference system<br />

Ag/AgCl/Tepox gel, Ag/AgCl/solid electrolyte, Ag/AgCl/Tepox gel - 3M KCl<br />

liquid<br />

Internal buffer <strong>pH</strong> 7<br />

Mechanical connection<br />

S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />

cable<br />

Electrical connection<br />

2 or 6 pole connection<br />

Temperature sensor<br />

none, Pt100, Pt1000<br />

29


Zirkon <strong>pH</strong> process<br />

Sensors<br />

Mechanical drawing<br />

S8 screw plug<br />

Sixplug<br />

203032100 ceramic PTFE hole<br />

S7 plug<br />

203038390<br />

30


Zirkon <strong>pH</strong> process<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

31


Zirkon <strong>pH</strong> process<br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24132150K 203032100 <strong>pH</strong> sensor: Tepox gel, 120 mm, platinum junction, S8 srew plug,<br />

follow-up of AH-300-K-2-3-PG<br />

24132140K 203032320 <strong>pH</strong> sensor: Tepox gel, 160 mm, platinum junction, S7 plug, follow-up of<br />

AH-300-K-2-3<br />

24132120K 203072100 <strong>pH</strong> sensor, Tepox gel, 120 mm, PTFE junction, S8 screw plug,<br />

follow-up of AH-300-K-2-7-PG<br />

24132121K 203172400 <strong>pH</strong> sensor: Tepox gel, 120 mm, PTFE junction, Pt 100, sixplug,<br />

follow-up of AH-305-K-2-7-PG<br />

Assembly version<br />

Article number type/configuration Description<br />

24132810K 203085100 <strong>pH</strong> sensor: solid electrolyte, hole, S8 srew plug, 120mm, follow-up of<br />

AH-300-K-5-8-PG<br />

24132501K 203038390 double chamber <strong>pH</strong> sensor: Tepox gel inside3M KCl liquid outside,<br />

platinum junction, S7 plug, 220mm, follow-up of AH-310-K-4-3<br />

32


Zirkon <strong>pH</strong> fluoride<br />

Sensors<br />

Zirkon <strong>pH</strong> fluoride<br />

Fluoride resistant<br />

Low maintenance by gel filling / Long life expectancy by refillable reference electrode<br />

Made in Germany<br />

Applications<br />

Fluoride Containing<br />

Media<br />

205011320 205072130 205072100<br />

Description<br />

Sensors of the series Zirkon <strong>pH</strong> fluoride are developed for the application in fluoride containing media. The special<br />

glass is resistant up to 500 m/l fluoride. The sensors are mainly used in the semiconducter industry. The sensor<br />

design such as like reference electrode and junction are mainly determined by the water characteristics.<br />

33


Zirkon <strong>pH</strong> fluoride<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

1.. 11 <strong>pH</strong><br />

Ambient conditions<br />

Max. pressure<br />

0.. 10 bar<br />

Min. condutctivity<br />

> 150 µS/cm<br />

Temperature 0.. 60 °C<br />

3M KCl Tepox gel<br />

Condutctivity > 50 µS/cm > 150 µS/cm<br />

plug PG PG 13,5 loose<br />

Pressure 0.. 10 bar at 20°C < 1 bar at 20°C<br />

PTFE hole ceramic platinum<br />

Pressure < 10 bar at 20°C < 1 bar pressureless < 2 bar at 20°C < 2 bar at 20°C<br />

Mechanical construction<br />

Junction<br />

ceramic 1 mm, zircon, PTFE, platinum, hole<br />

Shaft material<br />

Glass<br />

Mechanical Construction<br />

120 mm, 160 mm, 240 mm<br />

Electrode material<br />

S-glass-ball<br />

Reference system<br />

Ag/AgCl/3M KCl, Ag/AgCl/Tepox gel Ag/AgCl/solid electrolyte<br />

Internal buffer <strong>pH</strong> 7<br />

Mechanical connection<br />

S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />

cable<br />

Electrical connection<br />

2 or 6 pole connection<br />

Temperature sensor<br />

none, Pt100, Pt1000<br />

34


Zirkon <strong>pH</strong> fluoride<br />

Sensors<br />

Mechanical drawing<br />

S8 screw plug<br />

205012100 PTFE<br />

S7 plug<br />

205011320 hole ceramic<br />

35


Zirkon <strong>pH</strong> fluoride<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

36


Zirkon <strong>pH</strong> fluoride<br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24132410K 205012100 <strong>pH</strong> sensor: Tepox gel, 120 mm, ceramic junction, S8 screw plug,<br />

follow-up of S-300-K-2-1-PG<br />

24132400K 205012320 <strong>pH</strong> sensor: Tepox gel, 160 mm, ceramic junction, S7 plug, follow-up of<br />

S-300-K-2-1<br />

24132420K 205072100 <strong>pH</strong> sensor: Tepox gel, 120 mm, PTFE junction, S8 screw plug,<br />

follow-up of S-300-K-2-7-PG<br />

Assembly version<br />

Article number type/configuration Description<br />

24132300K 205011320 <strong>pH</strong> sensor: 3M KCl, 160 mm, ceramic junction, S7 plug, follow-up of<br />

S-300-K-1-1<br />

24132421K 205072130 <strong>pH</strong> sensor: Tepox gel, 240 mm, PTFE junction, S8 screw plug,<br />

follow-up of S-300-K-2-7-PG-240<br />

37


Zirkon <strong>pH</strong> process refill<br />

Sensors<br />

Zirkon <strong>pH</strong> process refill<br />

Long life expectancy by refillable reference electrode<br />

High precision by use of high alkaline high temperature glass<br />

Made in Germany<br />

Applications<br />

Process Water<br />

<strong>Dr</strong>inking Water /<br />

Beverages<br />

Waste Water Treatment<br />

204031320 204017390 204011320<br />

Description<br />

The sensors of the Zirkon <strong>pH</strong> process series are highly sophisticated sensors with a high value for money ratio. They<br />

are used in applications like process and waste water. We use our high performance AH glass with low alkaline error<br />

and a broad temperature range. We use different materials like ceramic, platinum or PTFE as junction. The junction<br />

and the electrolyte determine the salt output and the dirt resistance. As electrolyte we use our 3M KCl - this is<br />

refillable. As reference system we use a cartridge system which results in a constant measurement especially in<br />

applications with high temperature fluctuations.<br />

38


Zirkon <strong>pH</strong> process refill<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

0.. 14 <strong>pH</strong><br />

Ambient conditions<br />

Max. pressure<br />

< 1 bar pressureless<br />

Min. condutctivity<br />

> 50 µS/cm<br />

Temperature -5.. +100 °C<br />

plug PG PG 13,5 loose<br />

Pressure < 2 bar at 20°C < 1 bar at 20°C<br />

Mechanical construction<br />

Junction<br />

ceramic 1 mm, zircon, platinum, PTFE<br />

Shaft material<br />

Glass<br />

Mechanical Construction<br />

120 mm, 160 mm, 240 mm<br />

Electrode material<br />

AH glass ball<br />

Reference system<br />

Ag/AgCl/3M KCl liquid, Ag/AgCl/3M KCl liquid - 3M KCl liquid<br />

Internal buffer <strong>pH</strong> 7, <strong>pH</strong> 2<br />

Mechanical connection<br />

S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />

cable<br />

Electrical connection<br />

2 or 6 pole connection<br />

Temperature sensor<br />

none, Pt100, Pt1000<br />

39


Zirkon <strong>pH</strong> process refill<br />

Sensors<br />

Mechanical drawing<br />

204011320<br />

204017390<br />

40


Zirkon <strong>pH</strong> process refill<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

41


Zirkon <strong>pH</strong> process refill<br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24132040K 204011320 <strong>pH</strong> sensor: 3M KCI liquid, 160mm, ceramic junction, S7 plug, follow-up<br />

of AH-300-K-1-1<br />

24132050K 204031320 <strong>pH</strong> sensor: 3M KCl liquid, 160mm, platinum junction, S7 plug, follow-up<br />

of AH-300-K-1-3<br />

Assembly version<br />

Article number type/configuration Description<br />

24132510K 204017390 double chamber <strong>pH</strong> sensor: 3M KCI liquid inside and outside, 220mm,<br />

ceramic junction, S7 plug, follow-up model of AH-310-K-3-1<br />

42


Zirkon <strong>pH</strong> process refill<br />

Sensors<br />

Accessories<br />

accessories<br />

KCl vessel set<br />

Vessel-set for KCl liquid-filled <strong>pH</strong> or <strong>ORP</strong> sensors.<br />

The installation is possible on a wall or in the<br />

immersion assembly GE 23/3.<br />

Service-Set GE<br />

PG screw for sensors with 12 mm diameter. This<br />

screw enables the installation of liquid-filled sensors<br />

in the immersion assembly GE 23/3 or in the flow<br />

assembly GD (1) VG and GD (3) VG.<br />

43


Zirkon <strong>pH</strong> pure<br />

Sensors<br />

Zirkon <strong>pH</strong> pure<br />

Long life time by refillable reference electrode<br />

Measurement in media with very low conductivities by a higher flow rate<br />

Made in Germanry<br />

Applications<br />

Cooling water<br />

Ultra Pure Water<br />

Description<br />

202041320 202061320<br />

The sensors of the Zirkon <strong>pH</strong> pure are highly sophisticated sensors with a high value for money ratio. They are used<br />

in ion poor media. We use our high performance AH glass with low alkaline error and a broad temperature range.<br />

We use different materials like ceramic or glass sleeve as junction. The junction and the electrolyte are determine<br />

the salt output and therfore the measurement quality in ion poor media. As electrolyte we use our 3M KCl - this is<br />

refillable. As reference system we use a cartridge system which results in a constant measurement especially in<br />

applications with high temperature fluctuations.<br />

44


Zirkon <strong>pH</strong> pure<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

0.. 14 <strong>pH</strong><br />

Ambient conditions<br />

Max. pressure<br />

< 1 bar pressureless<br />

Temperature -5.. +100 °C<br />

3x2 mm ceramic glass sleeve<br />

Condutctivity > 50 µS/cm > 20 µS/cm<br />

plug PG PG 13,5 loose<br />

Pressure < 2 bar at 20 °C < 1 bar pressureless<br />

Mechanical construction<br />

Junction<br />

3 x 1 mm ceramic, glass sleeve<br />

Shaft material<br />

Glass<br />

Mechanical Construction<br />

160 mm<br />

Electrode material<br />

AH glass<br />

Reference system<br />

Ag/AgCl/3M KCl liquid<br />

Internal buffer <strong>pH</strong> 7<br />

Mechanical connection<br />

S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />

cable<br />

Electrical connection<br />

2 or 6 pole connection<br />

Temperature sensor<br />

none, Pt100, Pt1000<br />

45


Zirkon <strong>pH</strong> pure<br />

Sensors<br />

Mechanical drawing<br />

202041320<br />

202061320<br />

46


Zirkon <strong>pH</strong> pure<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

47


Zirkon <strong>pH</strong> pure<br />

Sensors<br />

Assembly version<br />

Article number type/configuration Description<br />

24132070K 202041320 <strong>pH</strong> sensor: 3M KCl liquid, 160 mm, ceramic junction, 160mm, follow-up<br />

model of AH-300-K-1-3x2<br />

24132010K 202061320 <strong>pH</strong> sensor: 3M KCl liquid, 160 mm, glass sleeve, S7 plug, 160mm,<br />

follow-up model of AH-300-K-1-6<br />

48


Zirkon <strong>pH</strong> pure<br />

Sensors<br />

Accessories<br />

accessories<br />

KCl vessel set<br />

Vessel-set for KCl liquid-filled <strong>pH</strong> or <strong>ORP</strong> sensors.<br />

The installation is possible on a wall or in the<br />

immersion assembly GE 23/3.<br />

Service-Set GE<br />

PG screw for sensors with 12 mm diameter. This<br />

screw enables the installation of liquid-filled sensors<br />

in the immersion assembly GE 23/3 or in the flow<br />

assembly GD (1) VG and GD (3) VG.<br />

49


Zirkon <strong>pH</strong> coating<br />

Sensors<br />

Zirkon <strong>pH</strong> coating<br />

Junction protectable<br />

Fluoride resistant<br />

According to DIN 55659 for <strong>pH</strong> measurement in electrophoretic dip painting<br />

Applications<br />

Laboratory<br />

Fluoride Containing<br />

Media<br />

Description<br />

206051320<br />

Sensors of the Zirkon <strong>pH</strong> coating series are developed for the use in lacquer and coatings. They are used in paint<br />

and coating industry. Crucial for the measurement in coatings is the contamination of the junction. This mainly<br />

determines the life expectancy of the sensor. In case of the Zirkon <strong>pH</strong> coating sensors the projecting junction can be<br />

protected with a membrane or a hole is used in combination with solid electrolyte instead of a junction.<br />

50


Zirkon <strong>pH</strong> coating<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value 1.00.. 11.00<br />

Ambient conditions<br />

Max. pressure<br />

< 1 bar pressure less<br />

Min. condutctivity<br />

> 50 µS/cm<br />

Temperature 0.. +60 °C<br />

KCl 3M liquid solid electrolyte<br />

Condutctivity > 50 µS/cm > 150 µS/cm<br />

Mechanical construction<br />

Junction<br />

ceramic 15 mm projecting, hole<br />

Shaft material<br />

Glass<br />

Mechanical Construction<br />

120 mm, 160 mm, 240 mm<br />

Electrode material<br />

S-Glass ball<br />

Reference system<br />

Ag/AgCl/3M KCl, Ag/AgCl/solid electrolyte<br />

Internal buffer <strong>pH</strong> 7<br />

Mechanical connection<br />

S8 plug (PG 13,5), S7 plug, SP6 plug (PG 13,5), VP plug (PG 13,5), fixed<br />

cable<br />

Electrical connection<br />

2 or 6 pole connection<br />

Temperature sensor<br />

none, Pt100, Pt1000<br />

51


Zirkon <strong>pH</strong> coating<br />

Sensors<br />

Mechanical drawing<br />

S8 screw plug<br />

206051320 hole<br />

52


Zirkon <strong>pH</strong> coating<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

53


Zirkon <strong>pH</strong> coating<br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24132320K 206051320 <strong>pH</strong> sensor: 3M KCl, 160 mm, ceramic junction (15 mm projecting), S7<br />

plug, follow-up of S-300-K-1-5<br />

54


Zirkon <strong>pH</strong> Pool<br />

Sensors<br />

Zirkon <strong>pH</strong> Pool<br />

Low maintenance<br />

Higher life expectancy by KCl reservoir<br />

Applications<br />

Swimming-Pool<br />

Description<br />

207013100 207013110<br />

Zirkon <strong>pH</strong> Pool sensors are electrodes for <strong>pH</strong> measurement in swimming pool applications. The sensor is gel filled<br />

with salt reservoir, not refillable and requires little maintenance. The 1 mm junction and the saltreservoir increase the<br />

expected life time.<br />

55


Zirkon <strong>pH</strong> Pool<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

0.00.. 14.00 <strong>pH</strong><br />

Ambient conditions<br />

Max. pressure 2 bar at 20°C<br />

Min. condutctivity<br />

> 150 µS/cm<br />

Temperature -5.. +70 °C<br />

Mechanical construction<br />

Junction<br />

Ceramic 1mm<br />

Shaft material<br />

Glass<br />

Mechanical Construction<br />

80 mm, 120 mm<br />

Electrode material<br />

AH glass ball<br />

Reference system<br />

Ag/AgCl/saturated KCl<br />

Internal buffer <strong>pH</strong> 7<br />

Mechanical connection<br />

S8 plug (PG 13,5), fixed cable<br />

Electrical connection<br />

2 pole connection<br />

Temperature sensor<br />

none<br />

Mechanical drawing<br />

207013100<br />

56


Zirkon <strong>pH</strong> Pool<br />

Sensors<br />

207013110<br />

57


Zirkon <strong>pH</strong> Pool<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

58


Zirkon <strong>pH</strong> Pool<br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24132700K 207013100 <strong>pH</strong> sensor: saturated KCl, 120 mm, ceramic junction, S8 screw plug,<br />

follow-up of AH-300-K-6-1-PG<br />

Assembly version<br />

Article number type/configuration Description<br />

24132730K 207013110 <strong>pH</strong> sensor: saturated KCl, 80 mm, ceramic junction, S8 screw plug,<br />

follow up of AH-308-K-6-1-PG<br />

59


Zirkon Rx<br />

Sensors<br />

Zirkon Rx<br />

Low maintenance by gel filling<br />

Made in Germany<br />

Applications<br />

Waste Water Treatment<br />

Disinfection<br />

Process Water<br />

211512100 211512320 211312100<br />

Description<br />

The <strong>ORP</strong> sensors Zirkon Rx allow <strong>ORP</strong> measurements in almost every kind of medium. They require little<br />

maintenance by the gel filling and the electrode assembly or the big electrode surface.<br />

60


Zirkon Rx<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>ORP</strong><br />

-1500.. +1500 mV<br />

Ambient conditions<br />

Max. pressure 2 bar at 20°C<br />

Min. condutctivity<br />

> 150 µS/cm<br />

Temperature -5.. +70 °C<br />

plug PG PG 13,5 loose<br />

Pressure < 2 bar at 20°C < 1 bar pressureless<br />

Mechanical construction<br />

Junction<br />

Shaft material<br />

Mechanical Construction<br />

Electrode material<br />

Reference system<br />

Mechanical connection<br />

Electrical connection<br />

Ceramic 1 mm<br />

Glass<br />

120 mm, 160 mm<br />

platinum ring, platinum plate, gold ring<br />

Ag/AgCl/Tepox gel<br />

S8 plug (PG 13,5), S7 plug, fixed cable<br />

2 pole connection<br />

61


Zirkon Rx<br />

Sensors<br />

Mechanical drawing<br />

S7 plug<br />

211312100<br />

211512320<br />

62


Zirkon Rx<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

63


Zirkon Rx<br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24135110K 211512320 <strong>ORP</strong> sensor: gold ring Tepox gel, ceramic junction, S7 plug, follow-up<br />

of Au-600-O-2-1<br />

24135120K 211512100 <strong>ORP</strong>sensor: gold ring Tepox gel, ceramic junction, S8 plug (PG 13,5),<br />

follow-up of Au-600-O-2-1-PG<br />

24135210K 211312320 <strong>ORP</strong> sensor: platinum cap, Tepox gel, ceramic junction, S7 plug,<br />

follow-up of Pt-600-O-2-1<br />

24135220K 211312100 <strong>ORP</strong> sensor: platinum cap, Tepox gel, ceramic junction, S8 plug (PG<br />

13,5), follow-up of Pt-600-O-2-1-PG<br />

64


Zirkon Rx process<br />

Sensors<br />

Zirkon Rx process<br />

Usable for aggressive media<br />

Low maintenance by gel filling<br />

Made in Germany<br />

Applications<br />

Waste Water Treatment<br />

Disinfection<br />

Process Water<br />

213512210<br />

Description<br />

The Zirkon Rx process sensors are have special chemical reistant materials meant for aggressive media. The<br />

sensors are equipped with gold or platinum rings for <strong>ORP</strong> measurement. The sensors are gel filled, non-refillable<br />

and require little maintenance.<br />

65


Zirkon Rx process<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>ORP</strong><br />

-1500.. +1500 mV<br />

Ambient conditions<br />

Max. pressure 2 bar at 20°C<br />

Min. condutctivity<br />

> 150 µS/cm<br />

Temperature -5.. +70 °C<br />

plug PG PG 13,5 loose<br />

Pressure < 2 bar at 20°C < 1 bar pressureless<br />

Mechanical construction<br />

Junction<br />

Shaft material<br />

Mechanical Construction<br />

Electrode material<br />

Reference system<br />

Mechanical connection<br />

Electrical connection<br />

ceramic 1 mm, zircon, platinum, PTFE, Loch<br />

Glass<br />

80 mm, 120 mm, 160 mm<br />

platinum ring, platinum plate, gold and platinum ring, gold ring<br />

Ag/AgCl/Tepox gel Ag/AgCl/ solid electrolyt<br />

S8 plug (PG 13,5), S8 plug for aggressive media, S7 plug, fixed cable<br />

2 pole connection<br />

66


Zirkon Rx process<br />

Sensors<br />

Mechanical drawing<br />

213512210<br />

67


Zirkon Rx process<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

68


Zirkon Rx process<br />

Sensors<br />

Assembly version<br />

Article number type/configuration Description<br />

24135135K 213512210 <strong>ORP</strong> sensor: gold ring, Tepox gel, 80 mm, ceramic junction, S8 plug<br />

PBT/30%GF, follow-up of Au-658-O-2-1-PG<br />

24134030K 213400320 <strong>ORP</strong> sensor: gold- and platinum ring, S7 plug, 160 mm, follow-up of<br />

AuPt-500-OO<br />

24135170K 213372100 <strong>ORP</strong> sensor: platinum cap, Tepox gel, 120 mm, ceramic junction, S8<br />

plug (PG 13,5), follow-up of Pt-600-O-2-7-PG<br />

69


Zirkon Rx process refill<br />

Sensors<br />

Zirkon Rx process refill<br />

Long life time by refillable reference electrode<br />

Broad temperature range<br />

Made in Germany<br />

Applications<br />

Waste Water Treatment<br />

Cooling water<br />

Process Water<br />

Description<br />

214311320<br />

Zirkon Rx process refill are refillable sensors for <strong>ORP</strong> measurement. The sensors have a high blocking resistance<br />

and are usable over a broad temperature range in nearly any kind of process water.<br />

70


Zirkon Rx process refill<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>ORP</strong><br />

-1500.. +1500 mV<br />

Ambient conditions<br />

Max. pressure<br />

< 1 bar drucklos<br />

Temperature -5.. +100 °C<br />

plug PG PG 13,5 loose<br />

Pressure < 2 bar at 20°C < 1 bar pressureless<br />

Mechanical construction<br />

Junction<br />

Shaft material<br />

Mechanical Construction<br />

Electrode material<br />

Reference system<br />

Mechanical connection<br />

Electrical connection<br />

ceramic, platinum<br />

Glass<br />

80 mm, 120 mm, 160 mm<br />

platinum ring, platinum plate, gold and platinum ring, platinum ring<br />

Ag/AgCl/3M KCl<br />

S7 plug, fixed cable<br />

2-pole connection<br />

71


Zirkon Rx process refill<br />

Sensors<br />

Mechanical drawing<br />

214311320<br />

72


Zirkon Rx process refill<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

73


Zirkon Rx process refill<br />

Sensors<br />

Assembly version<br />

Article number type/configuration Description<br />

24135200K 214311320 <strong>ORP</strong> sensor: platinum plate, 3M KCl liquid refillable, 160 mm, S7 plug<br />

with hose connection, ceramic junction, follow-up model of Pt-600-O-1-1<br />

74


Zirkon Rx process refill<br />

Sensors<br />

Accessories<br />

accessories<br />

KCl vessel set<br />

Vessel-set for KCl liquid-filled <strong>pH</strong> or <strong>ORP</strong> sensors.<br />

The installation is possible on a wall or in the<br />

immersion assembly GE 23/3.<br />

Service-Set GE<br />

PG screw for sensors with 12 mm diameter. This<br />

screw enables the installation of liquid-filled sensors<br />

in the immersion assembly GE 23/3 or in the flow<br />

assembly GD (1) VG and GD (3) VG.<br />

75


Zirkon Rx Pool<br />

Sensors<br />

Zirkon Rx Pool<br />

Low maintenance<br />

Higher life expectancy by KCl reservoir<br />

Made in Germany<br />

Applications<br />

Swimming-Pool<br />

Description<br />

217313100 217300100<br />

Zirkon Rx Pool sensors are sensors for <strong>ORP</strong> measurement in swimming pool applications. The sensors are gel filled<br />

with salt reservoir, not refillable and require little maintenance. The 1 mm junction and the salt reservoir increase the<br />

expected life time.<br />

76


Zirkon Rx Pool<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

<strong>ORP</strong><br />

-1500.. +1500 mV<br />

Ambient conditions<br />

Max. pressure 2 bar at 20°C<br />

Min. condutctivity<br />

> 150 µS/cm<br />

Temperature -5.. +70 °C<br />

Mechanical construction<br />

Junction<br />

Shaft material<br />

Mechanical Construction<br />

Electrode material<br />

Reference system<br />

Mechanical connection<br />

Electrical connection<br />

none, ceramic 1mm<br />

glass<br />

120 mm<br />

platinum plate<br />

None, Ag/AgCl/KCl saturated<br />

S8 plug (PG 13,5), fixed cable<br />

2-pole screw connection<br />

Mechanical drawing<br />

217313100<br />

77


Zirkon Rx Pool<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

78


Zirkon Rx Pool<br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24135285K 217313100 <strong>ORP</strong> sensor: platinum plate, KCl saturated, ceramic junction, S8 plug<br />

(PG 13,5), follow-up of Pt-600-P-6-1-PG<br />

24134010K 217300100 <strong>ORP</strong> electrode: platinum plate, S8 plug (PG 13,5), follow-up of<br />

Pt-500-P-PG<br />

79


Zirkon REF<br />

Sensors<br />

Zirkon REF<br />

Low maintenance by gel filling<br />

Made in Germany<br />

Applications<br />

Waste Water Treatment<br />

Cooling water<br />

Process Water<br />

224B12100<br />

221B12320<br />

Description<br />

Zirkon Ref are reference electrodes. They are used as reference point for other electrodes with relative potentials<br />

e.g. in <strong>pH</strong> or <strong>ORP</strong> measurement. The gel filled sensors need lower maintenance and are used in standard<br />

application.<br />

80


Zirkon REF<br />

Sensors<br />

Ambient conditions<br />

Max. pressure<br />

0.. 2 bar<br />

Min. condutctivity<br />

> 150 µS/cm<br />

Temperature -5.. +70 °C<br />

plug PG PG 13,5 loose<br />

Pressure < 2 bar at 20°C < 1 bar pressureless<br />

Mechanical construction<br />

Junction<br />

Shaft material<br />

Mechanical Construction<br />

Reference system<br />

Mechanical connection<br />

Electrical connection<br />

ceramic 1mm, platinum<br />

Glass<br />

120 mm, 160 mm, 240 mm<br />

Tepox gel<br />

S8 plug (PG 13,5), S7 plug, fixed cable<br />

2 pole connection<br />

Mechanical drawing<br />

S8 (PG 13,5)<br />

221B12320<br />

81


Zirkon REF<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

82


Zirkon REF<br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24133100K 221B12320 reference electrode: Tepox gel, 160 mm, 1 mm ceramic junction, S7<br />

plug, follow-up of B-400-B-2-1<br />

24133110K 221B22100 reference electrode: Tepox gel, 120 mm, 1 mm ceramic junction, S8<br />

(PG 13,5) plug, follow-up of B-400-B-2-1-PG<br />

Assembly version<br />

Article number type/configuration Description<br />

24133140K 221B32320 reference electrode: Tepox gel, 160 mm, platinum junction, S7 plug,<br />

follow-up of B-400-B-2-3<br />

83


Zirkon REF<br />

Sensors<br />

Accessories<br />

sensors<br />

AH-200-K<br />

The <strong>pH</strong> electrode AH-200-K is a single measuring<br />

electrode. To measure <strong>pH</strong>, it has to be used in<br />

combination with a separate reference electrode.<br />

Combination electrodes with integrated reference are<br />

easier to calibrate and to install, but in very<br />

aggressive solutions that shorten the life time of either<br />

the reference or the measuring electrode, it might still<br />

be advantageous to use separate measuring and<br />

reference electrodes.<br />

84


Zirkon REF process refill<br />

Sensors<br />

Zirkon REF process refill<br />

Long life time by refill<br />

Sensor protection via electrolyte bridge<br />

Made in Germany<br />

Applications<br />

Process Water<br />

Waste Water Treatment<br />

Ultra Pure Water<br />

224B11320 224E10000 224E30001<br />

Description<br />

Zirkon Ref refill are refillable reference electrodes. They are used as a reference point for other electrodes with<br />

relative potentials e.g. in <strong>pH</strong> or <strong>ORP</strong> measurements. The liquid filled sensor is mainly used in waste water. For highly<br />

polluted measuring media the electrolyte bridges are recommended, because the reference electrode will not be in<br />

contact with the measuring media.<br />

85


Zirkon REF process refill<br />

Sensors<br />

Ambient conditions<br />

Max. pressure<br />

1 bar pressureless<br />

Min. condutctivity<br />

> 50 µS/cm<br />

Temperature -5.. +100 °C<br />

platinum junction Keramikdiaphragma<br />

Condutctivity < 50 µS/cm > 50 µS/cm<br />

Mechanical construction<br />

Junction<br />

Shaft material<br />

Mechanical Construction<br />

Reference system<br />

Mechanical connection<br />

Electrical connection<br />

ceramic 1 mm, platinum<br />

Glass<br />

160 mm, 180 mm<br />

none, 3M KCl liquid<br />

none, S7 plug<br />

none, 2 pole connection<br />

Mechanical drawing<br />

224B11320<br />

86


Zirkon REF process refill<br />

Sensors<br />

224E10000<br />

224E30001<br />

87


Zirkon REF process refill<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

88


Zirkon REF process refill<br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24133800K 224E10000 electrolyte bridge: 1 mm ceramic junction, follow-up of EB-400-B-1x1<br />

24133830K 224E30001 electrolyte bridge: 2 x platinum junction, follow-up of EB-400-B-2x3<br />

24133000K 224B11320 reference electrode: 3M KCl liquid, ceramic junction, follow-up of<br />

B-400-B-1-1<br />

89


Zirkon T<br />

Sensors<br />

Zirkon T<br />

Fast response - t90 = 15 sec<br />

Chemical resistant<br />

Pt100 and Pt1000 available<br />

Applications<br />

Laboratory<br />

<strong>Dr</strong>inking Water /<br />

Beverages<br />

Process Water<br />

271100100 / 271200100<br />

Description<br />

Zirkon T are high quality temperature sensors based on the resistance change of platinum wire as a function of<br />

temperature. They are specially designed to give fast response, with a t90 of 15 seconds.<br />

90


Zirkon T<br />

Sensors<br />

Technical data<br />

Measuring parameter<br />

Temperature -20.0.. +130.0 °C<br />

Ambient conditions<br />

Max. pressure < 16 bar at 20°C<br />

Mechanical construction<br />

Shaft material<br />

glass<br />

Mechanical Construction<br />

80 mm, 120 mm, 160 mm, 240 mm, special length<br />

Mechanical connection<br />

S8 plug (PG 13,5), S7 plug, SP6 plug<br />

Electrical connection<br />

2 pole screw connection; 6 pole screw connection (SP plug)<br />

Temperature sensor Pt 100; Pt 1000<br />

Mechanical drawing<br />

Sixplug<br />

271100100<br />

91


Zirkon T<br />

Sensors<br />

Order information<br />

If possible, choose items listed under "storage versions" or "assembly versions" for your orders. We will have to<br />

technically inspect and approve a free combination of individual key features.<br />

92


Zirkon T<br />

Sensors<br />

Storage version<br />

Article number type/configuration Description<br />

24137011K 271100100 Temperature sensor: Pt 100, 120 mm, S8 plug<br />

24137012K 271200100 Temperature sensor: Pt 1000, 120 mm, S8 plug<br />

Assembly version<br />

Article number type/configuration Description<br />

24137013K 271100600 Temperature sensor: Pt 100, 120 mm, Sixplug<br />

24137014K 271200600 Temperature sensor: Pt 1000, 120 mm, Sixplug<br />

93


GD 1 V(G) (PP)<br />

Assemblies<br />

GD 1 V(G) (PP)<br />

Easy to dismantle<br />

Ideal for sensors with thread PG 13,5<br />

Easy mounting by bonding or 1'' female thread<br />

GD 1 VG<br />

Description<br />

Flow assembly for installation of one <strong>pH</strong> or <strong>ORP</strong> sensor in pipes with adhesive coupling or pipe coupling DN 25 with<br />

1" female thread. Available in PVC and PP.<br />

Technical data<br />

Ambient conditions<br />

Max. pressure<br />

Temperature<br />

PVC: 16 bar (at 20°C) PP: 10 bar (at 20°C)<br />

max 40 °C (PVC) max. 90 °C (PP)<br />

Mechanical construction<br />

Material<br />

PVC, PP<br />

Dimensions<br />

see dimension drawing<br />

Installation GD 1 V: adhesive coupling GD 1 VG (PP): pipe coupling DN 25 with 1"<br />

female thread<br />

94


GD 1 V(G) (PP)<br />

Assemblies<br />

Mechanical drawing<br />

GD 1 V(G)<br />

product variants<br />

Article number type/configuration Description<br />

36604261K GD 1 V adhesive coupling (DN 25), PVC<br />

36604263K GD 1 VG pipe coupling (DN 25) with 1'' internal thread, PVC<br />

36604265K GD 1 VG PP pipe coupling (DN 25) with 1'' internal thread, PP<br />

95


GD 43<br />

Assemblies<br />

GD 43<br />

Easy to dismantle<br />

Ideal for sensors with S8 screw plug-in (PG 13,5)<br />

Transparent<br />

GD 43<br />

Description<br />

Flow assembly for installation of max 3 sensors(e.g. <strong>pH</strong> and/ or <strong>ORP</strong> electrodes and temperature sensors) in pipes.<br />

Particular characteristics<br />

Easy to dismantle<br />

Ideal for sensors with S8 screw plug-in (PG 13,5)<br />

Transparent<br />

Technical data<br />

Ambient conditions<br />

Max. pressure<br />

6 bar (at 20°C)<br />

Temperature max. 60 °C<br />

Mechanical construction<br />

Material<br />

Dimensions<br />

Installation<br />

PP, Makrolon<br />

see dimension drawing<br />

Fittings 6/8 mm hoses or pipes<br />

96


GD 43<br />

Assemblies<br />

Mechanical drawing<br />

GD 43<br />

product variants<br />

Article number type/configuration Description<br />

36601171K GD 43 for max. 3 sensors<br />

97


GE 251 PP<br />

Assemblies<br />

GE 251 PP<br />

With protective cage to protect the sensor<br />

Fitting head with cable gland<br />

Easy access to sensor<br />

Fastening with pipe clamps<br />

GE 251<br />

Description<br />

Immersion assembly for installation of one <strong>pH</strong> or <strong>ORP</strong> sensor<br />

Technical data<br />

Ambient conditions<br />

Temperature max. 90 °C<br />

Mechanical construction<br />

Material<br />

Dimensions<br />

PP<br />

see dimensional drawing<br />

98


GE 251 PP<br />

Assemblies<br />

Mechanical drawing<br />

GE 251 PP<br />

product variants<br />

Article number type/configuration Description<br />

36511020K GE 251 PP immersion assembly for one <strong>pH</strong> or <strong>ORP</strong> sensor<br />

99


GE 251 PP<br />

Assemblies<br />

Accessories<br />

accessories<br />

Moisture cap<br />

Moisture cap for GE 23/3 PP For a longer period <strong>pH</strong>and<br />

<strong>ORP</strong> sensor shouldn´t dry, the moistuire cap<br />

avoid this.<br />

100


GE 23/3 PP<br />

Assemblies<br />

GE 23/3 PP<br />

Protection of the sensors by protective cage<br />

Easy fastening by pipe clamps or angle braket<br />

Installation set for KCl-vessel available<br />

GE 23/3 PP<br />

Description<br />

Immersion assembly for max. 3 sensors (<strong>pH</strong>, <strong>ORP</strong> and/or temperature sensors) in tanks or basins.<br />

Technical data<br />

Ambient conditions<br />

Temperature max. 90°C<br />

Mechanical construction<br />

Material<br />

Dimensions<br />

PP<br />

see dimension drawing<br />

101


GE 23/3 PP<br />

Assemblies<br />

Mechanical drawing<br />

GE 23/3 PP<br />

product variants<br />

Article number type/configuration Description<br />

36510012K GE 23/3 PP for max. 3 sensors, PP<br />

102


GE 23/3 PP<br />

Assemblies<br />

Accessories<br />

accessories<br />

Moisture cap<br />

Moisture cap for GE 23/3 PP For a longer period <strong>pH</strong>and<br />

<strong>ORP</strong> sensor shouldn´t dry, the moistuire cap<br />

avoid this.<br />

MW/MD GE 23/3<br />

PP<br />

Angle braket for the immersion assembly GE 23/3<br />

VA-Pole for<br />

KCl-vessel<br />

For installation of KCl vessel in flow assembly GE<br />

23/3<br />

KCl vessel set<br />

Vessel-set for KCl liquid-filled <strong>pH</strong> or <strong>ORP</strong> sensors.<br />

The installation is possible on a wall or in the<br />

immersion assembly GE 23/3.<br />

Service-Set GE<br />

PG screw for sensors with 12 mm diameter. This<br />

screw enables the installation of liquid-filled sensors<br />

in the immersion assembly GE 23/3 or in the flow<br />

assembly GD (1) VG and GD (3) VG.<br />

103


PM 6<br />

Handheld Units<br />

PM 6<br />

Automatic or manual temperature compensation<br />

Test of electrode quality<br />

Min/ max value memory, hold function<br />

PM 6 Set<br />

Description<br />

All-purpose portable measuring instrument for measurement of <strong>pH</strong>, <strong>ORP</strong> and temperature. Connection of <strong>pH</strong> and<br />

<strong>ORP</strong> combination electrodes with and without Pt 100 is possible. Handheld instrument, sensor and <strong>pH</strong> 4 and <strong>pH</strong> 7<br />

buffer solution each 50 mL in a portable case are included in delivery.<br />

Particular characteristics<br />

Automatic or manual temperature compensation<br />

Automatic power shut-off<br />

Double display for measured value and temperature<br />

Power supply by battery or rechargeable<br />

Easy and safe handling by 6 soft keys<br />

Low battery indication<br />

With fold away support<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

0.. 14 <strong>pH</strong><br />

<strong>ORP</strong><br />

-1999.. +1999 mV<br />

Temperature -100.. +250 °C<br />

104


PM 6<br />

Handheld Units<br />

Power supply<br />

Line voltage<br />

Power supply<br />

Power consumption<br />

via 10-12 V (power unit not included in delivery)<br />

9V battery<br />

ca. 3 mA<br />

Ambient conditions<br />

Ambient temperature operation 0 .. 50°C storage -20° .. 70°C<br />

Relative humidity<br />

max. 90% rH at 40°C (non-condensing)<br />

Protection class IP 65<br />

Connections<br />

Sensor<br />

BNC plug (<strong>pH</strong>/<strong>ORP</strong>) female mini DIN plug (T)<br />

Certificates and approvals<br />

CE-Symbol<br />

Declaration of conformity: The product meets the requirements of the<br />

harmonized European standards. It thus complies with the legal requirements<br />

of the EC directives. The manufacturer confirms successful testing of the<br />

product by affixing the CE symbol.<br />

product variants<br />

Article number type/configuration Description<br />

65512510K PM 6 complete set measuring instrument with sensor (Zirkon <strong>pH</strong> 201012103),<br />

cable and each 50 ml buffer solution <strong>pH</strong> 4 and <strong>pH</strong> 7 including portable<br />

case<br />

105


PM 6<br />

Handheld Units<br />

Accessories<br />

accessories<br />

COAX-D-2-1,5<br />

Coaxial cable with sensor and BNC plug, length 1,5 m<br />

<strong>pH</strong> buffer solutions<br />

The slope of <strong>pH</strong> sensors changes over the time<br />

(depending on the measuring media). We recomment<br />

a regular calibration with our buffer solutions. We offer<br />

1000 ml packages of <strong>pH</strong> 2, <strong>pH</strong> 3,56, <strong>pH</strong> 4, <strong>pH</strong> 7, and<br />

<strong>pH</strong> 9,22, and 50 ml packages of <strong>pH</strong> 4, and <strong>pH</strong> 7.<br />

106


PH-T<br />

Handheld Units<br />

PH-T<br />

Testing of <strong>pH</strong>- and <strong>ORP</strong> sensors<br />

Testing of <strong>pH</strong> and <strong>ORP</strong> instruments and cables<br />

PH-T Set<br />

Description<br />

<strong>pH</strong> and mV simulator to check <strong>pH</strong> and <strong>ORP</strong> measuring instruments and electrodes. Complete set: simulator with<br />

cable and adapter in a portable case.<br />

Particular characteristics<br />

High-impedance test (>1000MOhm)<br />

Voltage measurement in mV<br />

Presetting of voltage in mV or <strong>pH</strong><br />

Power supply or rechargeable<br />

Technical data<br />

Measuring parameter<br />

<strong>ORP</strong><br />

-1500.. +1500 mV<br />

Input characteristics<br />

Accuracy<br />

+/- 1 mV<br />

Output characteristics<br />

Voltage presetting<br />

Ph-simulation<br />

-1500 .. +1500 mV<br />

0 .. 14 <strong>pH</strong><br />

107


PH-T<br />

Handheld Units<br />

Power supply<br />

Line voltage<br />

Power supply<br />

Ladestrom<br />

input voltage about 15-16 V, barrel connector AD 5 mm, ID 2mm<br />

9 V battery or 9 V rechargeable battery<br />

18 - 20 mA<br />

Ambient conditions<br />

Ambient temperature operation 0 .. +40 °C storage -20 .. +65 °C<br />

Relative humidity<br />

max. 90% rF at 40°C (non-condensing)<br />

Protection class IP 40<br />

Connections<br />

Sensor<br />

BNC plug<br />

Certificates and approvals<br />

CE-Symbol<br />

Declaration of conformity: The product meets the requirements of the<br />

harmonized European standards. It thus complies with the legal requirements<br />

of the EC directives. The manufacturer confirms successful testing of the<br />

product by affixing the CE symbol.<br />

product variants<br />

Article number type/configuration Description<br />

45512800K PH-T complete set: simulator with caable and adapter incl portable case<br />

108


PH-T<br />

Handheld Units<br />

Accessories<br />

accessories<br />

COAX-D-2-1,5<br />

Coaxial cable with sensor and BNC plug, length 1,5 m<br />

109


S-341 data logger<br />

Accessories<br />

S-341 data logger<br />

Free administration of 10 instruments with up to 8 parameter each<br />

Data storing takes place up to every second<br />

S-341 data logger<br />

Description<br />

The bus data logger S-341 on the base of the RS-485 with <strong>Kuntze</strong> protocol reads, shows, and stores measuring<br />

data of up to 10 <strong>Kuntze</strong> instruments with up to 8 parameters each.<br />

Particular characteristics<br />

available in German, English or French menu guidance<br />

data storing in 24h files in text format<br />

storage media is standard SD-card (max. 1 GB, FAT 12/16)<br />

Graphical program vario view2 is available free of charge<br />

Technical data<br />

Power supply<br />

Voltage supply<br />

20...253 VDC or 50...253 VAC<br />

Ambient conditions<br />

Ambient temperature<br />

panel mounted housing (91x44x131)<br />

110


S-341 data logger<br />

Accessories<br />

Mechanical construction<br />

Installation dimensions<br />

panel mounted housing (91x44x131)<br />

product variants<br />

Article number type/configuration Description<br />

42001000K S-341 data logger bus data logger based on RS 485 with <strong>Kuntze</strong> protocol<br />

111


COAX-D-AE-X<br />

Accessories<br />

COAX-D-AE-X<br />

Low-noise<br />

Singled screened<br />

Electrode connector<br />

Wire end ferrules<br />

Integrated semiconductor layer for antistatic protection<br />

Description<br />

Single screened cable for connecting <strong>pH</strong>- and <strong>ORP</strong> sensors, available in 3, 5 and 10.<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

0.. 14 <strong>pH</strong><br />

Ambient conditions<br />

Ambient temperature -20 .. + 70°C<br />

Mechanical construction<br />

Material<br />

PVC<br />

112


COAX-D-AE-X<br />

Accessories<br />

product variants<br />

Article number type/configuration Description<br />

44136007K COAX-D-AE-3 connection cable for <strong>pH</strong> and <strong>ORP</strong> sensors, 3 m<br />

44136009K COAX-D-AE-5 connection cable for <strong>pH</strong> and <strong>ORP</strong> sensors, 5 m<br />

44136011K CoAX-D-AE-10 connection cable for <strong>pH</strong> and <strong>ORP</strong> sensors, 10 m<br />

113


TRIAX-D-1-X<br />

Accessories<br />

TRIAX-D-1-X<br />

Low-noise<br />

Dual screened<br />

Electrode connector<br />

Integrated semiconductor layer for antistatic protection<br />

Description<br />

Dual screened cable for connecting <strong>pH</strong> sensors, available in 3 and 5 m.<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

0.. 14 <strong>pH</strong><br />

Ambient conditions<br />

Ambient temperature -20 .. + 70°C<br />

Mechanical construction<br />

Material<br />

PVC<br />

product variants<br />

Article number type/configuration Description<br />

44136120K TRIAX-D-1-3 double screened connection cable for <strong>pH</strong> sensors, 3 m<br />

44136125K TRIAX-D-1-5 double screened connection cable for <strong>pH</strong> sensors, 5 m<br />

114


IWA 11.4<br />

Accessories<br />

IWA 11.4<br />

converts the high-impedance signal into a less sensitive low-impedance signal<br />

Connection between IWA and measuring instrument is possible with standard cable (up to<br />

1000 m length)<br />

Screened PVC housing<br />

Applications<br />

Waste Water Treatment<br />

Process Water<br />

<strong>Dr</strong>inking Water /<br />

Beverages<br />

Food Industry<br />

IWA 11.4<br />

Description<br />

Impedance converter - for longer distances between electrode and measuring instrument or under unfavourable<br />

installation conditions.<br />

Technical data<br />

Input characteristics<br />

Input resistor<br />

10^12 Ohm<br />

Output characteristics<br />

Output resistor<br />

1 kOhm<br />

Power supply<br />

Voltage supply<br />

+/- 5 .. 15 V<br />

115


IWA 11.4<br />

Accessories<br />

Ambient conditions<br />

Ambient temperature max. 50°C<br />

product variants<br />

Article number type/configuration Description<br />

47890101K IWA 11.4 impedance converter<br />

116


2CORE-D-1-X<br />

Accessories<br />

2CORE-D-1-X<br />

Low cable capacitance<br />

Screened<br />

Electrode connector<br />

Description<br />

Cable for connecting temperature sensors, available in 3, 5 and 10 m.<br />

Technical data<br />

Measuring parameter<br />

<strong>pH</strong>-value<br />

0.. 14 <strong>pH</strong><br />

Ambient conditions<br />

Ambient temperature -20 .. + 70°C<br />

Mechanical construction<br />

Material<br />

PVC<br />

product variants<br />

Article number type/configuration Description<br />

44136071K 2CORE-D-1-3 connection cable for Pt 100 sensors, 3 m<br />

44136066K 2CORE-D-1-5 connection cable for Pt 100 sensors, 5 m<br />

44136081K 2CORE-D-1-10 connection cable for Pt 100 sensors, 10 m<br />

117


<strong>pH</strong> buffer solutions<br />

Accessories<br />

<strong>pH</strong> buffer solutions<br />

For calibration of <strong>pH</strong> sensors<br />

<strong>pH</strong>-buffer solution<br />

Description<br />

The slope of <strong>pH</strong> sensors changes over the time (depending on the measuring media). We recomment a regular<br />

calibration with our buffer solutions. We offer 1000 ml packages of <strong>pH</strong> 2, <strong>pH</strong> 3,56, <strong>pH</strong> 4, <strong>pH</strong> 7, and <strong>pH</strong> 9,22, and 50<br />

ml packages of <strong>pH</strong> 4, and <strong>pH</strong> 7.<br />

product variants<br />

Article number type/configuration Description<br />

95212000K <strong>pH</strong> 2 - cal 1000 ml buffer solution <strong>pH</strong> 2<br />

95212003K <strong>pH</strong> 3,56 - cal 1000 ml buffer solution <strong>pH</strong> 3,56<br />

95212007K <strong>pH</strong> 4 - cal 1000 ml buffer solution <strong>pH</strong> 4<br />

95212010K <strong>pH</strong> 4 - cal 50 ml buffer solution <strong>pH</strong> 4<br />

95212001K <strong>pH</strong> 7 - cal 1000 ml buffer solution <strong>pH</strong> 7<br />

95212009K <strong>pH</strong> 7 - cal 50 ml buffer solution <strong>pH</strong> 7<br />

95212004K <strong>pH</strong> 9,22 -cal 1000 ml buffer solution <strong>pH</strong> 9,22<br />

118


The <strong>Dr</strong>. A. <strong>Kuntze</strong> <strong>GmbH</strong> "Terms and Conditions" will be applicable.<br />

<strong>pH</strong>/ <strong>ORP</strong><br />

Notes


Powered by TCPDF (www.tcpdf.org)<br />

<strong>Dr</strong>. A. <strong>Kuntze</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 7a | D-40668 Meerbusch | Germany<br />

Fon +49 (0) 2150 70 66 -0 | Fax +49 (0) 2150 70 66 -60<br />

info@kuntze.com | www.kuntze.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!