C i r c u i t B a r ® - Industrial and Bearing Supplies
C i r c u i t B a r ® - Industrial and Bearing Supplies
C i r c u i t B a r ® - Industrial and Bearing Supplies
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
C i r c u i t B a r<br />
®
CIRCUIT BAR ®<br />
CIRCUIT BAR ® is an extruded block of aluminum with pneumatic circuits machined right in the bar.<br />
The design of these circuits can be very simple or complex depending upon the requirements of the<br />
application.<br />
CIRCUIT BAR ® are a means by which individual components (i.e. valves, regulators <strong>and</strong> flow controls)<br />
comprising a circuit, can be combined into one extruded CIRCUIT BAR ® . The CIRCUIT BAR ® will eliminate<br />
extra piping <strong>and</strong> fittings, as well as saving space <strong>and</strong> money.<br />
Contact your local MAC distributor for more information as to how MAC’S CIRCUIT BAR ® can satisfy<br />
your needs.<br />
Introduction<br />
Section 1 Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Introduction<br />
Let us show you via high performance demonstration kits <strong>and</strong> animated software,<br />
HOW MAC’S PERFORMANCE ADVANTAGES HELP MAKE YOUR<br />
EQUIPMENT MORE RELIABLE - FASTER - MORE REPEATABLE.<br />
TLD<br />
Traveling Lab Demonstration measures critical valve<br />
performance characteristics - Shifting forces,<br />
Response Time, Speed, Repeatability <strong>and</strong> Flow.<br />
PLD<br />
Proportional Lab Demonstration measures critical<br />
proportional regulation characteristics - Response<br />
Time, Accuracy, Hysterisis, Repeatability <strong>and</strong> Flow.<br />
Animation<br />
Animated Software shows inner workings of various<br />
Air Valves Designs - Powerful educational tool for<br />
learning about how air valves function.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Product range<br />
3-way solenoid operated valves<br />
#10-32 to 2 1/2” port size Cv .10 to 65.0<br />
4-way solenoid operated valves<br />
#10-32 to 1 1/2” port size Cv .10 to 15.9<br />
Proportional pressure control valves<br />
St<strong>and</strong> alone or Multi-Pressure Pak ®<br />
Analog or Digital with an overall accuracy range of ±.5% to ±2.5% of full scale<br />
Field bus products<br />
Communication Electronics with a variety of MAC Valves’ products<br />
Input <strong>and</strong> Output capability with a variety of protocols<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Section 1 Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Function Port size Flow (Max) C v Circuit bar mounting Series<br />
non plug-in<br />
cylinder ports<br />
in base<br />
non plug-in<br />
cylinder ports<br />
in valve<br />
plug-in<br />
plug-in<br />
with F. C.<br />
plug-in<br />
with Pr. Reg.<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
add-on style<br />
plug-in<br />
add-on style<br />
plug-in<br />
with F. C.<br />
add-on style<br />
plug-in<br />
with Pr. Reg.<br />
3/2<br />
M5 - #10-32<br />
0.11<br />
3/2<br />
3/2<br />
#10-32 - 1/8”<br />
M5 - #10-32<br />
0.11<br />
0.10<br />
34<br />
3/2<br />
M5 - #10-32<br />
0.09<br />
3/2<br />
1/8” NPTF - #10-32 UNF<br />
0.10<br />
35<br />
3/2<br />
1/4” - 3/8”<br />
0.5<br />
3/2<br />
1/8” - 1/4”, 6mm tube receptacle<br />
0.5<br />
37<br />
3/2<br />
1/8” - 1/4”<br />
0.5<br />
5/2 - 3/2<br />
M5 - #10-32<br />
0.093<br />
5/2 - 3/2<br />
#10-32 - 1/8”<br />
0.093<br />
5/2 - 3/2<br />
M5 - #10-32<br />
0.09<br />
44<br />
5/2 - 3/2<br />
M5 - #10-32<br />
0.08<br />
5/2 - 3/2<br />
M5 - #10-32<br />
0.07<br />
4/2<br />
1/8” NPTF - #10-32 UNF<br />
0.10<br />
45<br />
5/2<br />
5/2<br />
1/8” - 1/4”, 6mm tube receptacle<br />
1/8” - 1/4”<br />
0.5<br />
0.5<br />
47<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Function Port size Flow (Max) C v Circuit bar mounting Series<br />
add-on style<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
plug-in<br />
add-a-unit<br />
stations<br />
plug-in<br />
add-a-unit<br />
stations<br />
with F. C.<br />
plug-in<br />
add-a-unit<br />
stations<br />
with Pr. Reg.<br />
plug-in<br />
add-a-unit<br />
stations with<br />
F. C. <strong>and</strong> Pr. Reg.<br />
plug-in with<br />
pre-wired<br />
connector<br />
plug-in<br />
with F. C. <strong>and</strong><br />
pre-wired<br />
connector<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> pre-wired<br />
connector<br />
din rail,<br />
plug-in with<br />
pre-wired<br />
connector<br />
3/2<br />
M5 - #10-32<br />
0.10<br />
3/2<br />
M5 - #10-32<br />
0.09<br />
34<br />
3/2<br />
M5 - #10-32, 4mm tube receptacle<br />
0.11<br />
3/2<br />
3/2<br />
1/8” - 1/4”, 6mm tube receptacle<br />
1/8” - 1/4”<br />
0.5<br />
0.5<br />
37<br />
5/2 - 3/2<br />
M5 - #10-32<br />
0.09<br />
5/2 - 3/2<br />
M5 - #10-32<br />
0.07<br />
5/2<br />
5/2<br />
M5 - #10-32<br />
M5 - #10-32<br />
0.09<br />
0.08<br />
44<br />
5/2<br />
M5 - #10-32<br />
0.07<br />
5/2 - 3/2<br />
M5 - #10-32, 4mm tube receptacle<br />
0.10<br />
5/2<br />
5/2<br />
1/8” - 1/4”, 6mm tube receptacle<br />
1/8” - 1/4”<br />
0.5<br />
0.5<br />
47<br />
Function Port size Flow (Max) C v Circuit bar mounting Series<br />
din rail,<br />
plug-in with F. C.<br />
<strong>and</strong> pre-wired<br />
connector<br />
non plug-in<br />
non plug-in<br />
with Pr. Reg.<br />
plug-in<br />
with side<br />
Pr. Reg.<br />
plug-in<br />
with integral<br />
terminal strip<br />
plug-in with<br />
integral<br />
terminal strip<br />
<strong>and</strong> side Pr. Reg.<br />
non plug-in<br />
cylinder ports<br />
in base with<br />
Pr. Reg.<br />
non plug-in<br />
add-on style<br />
cylinder ports<br />
in base<br />
non plug-in<br />
add-a-unit<br />
stations<br />
3/2<br />
M5 - #10-32, 4mm tube receptacle<br />
0.11<br />
34<br />
3/2<br />
1/8” NPTF - #10-32 UNF<br />
0.10<br />
35<br />
3/2<br />
1/8” - 1/4”, 6mm tube receptacle<br />
0.5<br />
37<br />
4/2<br />
1/8” NPTF - #10-32 UNF<br />
0.10<br />
45<br />
5/2<br />
1/8” - 1/4”, 6mm tube receptacle<br />
0.5<br />
47<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Function Port size Flow (Max) C v Circuit bar mounting Series<br />
cylinder ports<br />
in valve<br />
add-on style<br />
cylinder ports<br />
in valve<br />
cylinder ports<br />
in base<br />
add-on style<br />
cylinder ports<br />
in base<br />
add-a-unit<br />
stations for<br />
CBM052A bar<br />
add-a-unit<br />
stations for<br />
CBP052A bar<br />
non plug-in<br />
with or<br />
without F. C.<br />
non plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
plug-in<br />
with s<strong>and</strong>wich<br />
Pr. Reg.<br />
3/2<br />
1/8” - 1/4”<br />
1.2<br />
52<br />
4/2<br />
1/8” NPTF - #10-32 UNF<br />
0.10<br />
45<br />
5/2 - 5/3<br />
1/4”<br />
1.3<br />
800<br />
Function Port size Flow (Max) C v Circuit bar mounting Series<br />
plug-in with<br />
integral terminal<br />
strip <strong>and</strong><br />
s<strong>and</strong>wich Pr. Reg.<br />
plug-in with<br />
integral<br />
terminal strip<br />
with F. C.<br />
plug-in with<br />
integral terminal<br />
strip with<br />
Pr. Reg. <strong>and</strong> F. C.<br />
non plug-in<br />
cyl. ports in<br />
valve with<br />
opt. F. C.<br />
non plug-in<br />
cyl. ports in<br />
base with<br />
opt. F. C.<br />
add-on style<br />
non plug-in cyl.<br />
ports in valve<br />
with opt. F. C.<br />
add-on style<br />
non plug-in cyl.<br />
ports in base<br />
with opt. F. C.<br />
non plug-in<br />
cyl. ports<br />
in valve with<br />
opt. Pr. Reg.<br />
add-on style<br />
non plug-in<br />
cyl. ports<br />
in base<br />
4/2<br />
1/8” NPTF - #10-32 UNF<br />
0.10<br />
45<br />
5/2<br />
5/2<br />
3/8”<br />
1/8” - 1/4”, 6mm tube receptacle<br />
0.5<br />
0.5<br />
47<br />
Function Port size Flow (Max) C v Circuit bar mounting Series<br />
add-on style<br />
non plug-in cyl.<br />
ports in base<br />
with Pr. Reg.<br />
low profile<br />
cylinder ports<br />
in valve<br />
low profile<br />
cylinder ports<br />
in base<br />
mid profile<br />
cylinder ports<br />
in valve<br />
mid profile -<br />
add on style<br />
cylinder ports<br />
in valve<br />
add-a-unit<br />
stations for<br />
CBM403A bar<br />
mid profile<br />
cylinder ports<br />
in base<br />
mid profile -<br />
add on style<br />
cylinder ports<br />
in base<br />
add-a-unit<br />
stations for<br />
CBM404A bar<br />
5/2<br />
1/8” - 1/4”, 6mm tube receptacle<br />
0.5<br />
47<br />
5/2 - 5/3<br />
5/2 - 5/3<br />
1/8” - 1/4”<br />
1/8”<br />
1.0<br />
1.0<br />
400<br />
Function Port size Flow (Max) C v Circuit bar mounting Series<br />
high profile<br />
cylinder ports<br />
in base<br />
high profile -<br />
add on style<br />
cylinder ports<br />
in base<br />
add-a-unit<br />
stations for<br />
CBM405A bar<br />
st<strong>and</strong>ard<br />
add-on style<br />
add-a-unit<br />
stations for<br />
CBM092B<br />
with shut-off<br />
valve<br />
5/2 - 5/3<br />
1/8” - 1/4”<br />
1.0<br />
400<br />
5/2 - 5/3 - 3/2<br />
1/8 - 1/4 - 3/8<br />
1.0<br />
92<br />
5/2 - 5/3<br />
1/4”<br />
1.3<br />
800<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Circuit bar mounting<br />
non plug-in<br />
cylinder ports<br />
in base<br />
non plug-in<br />
cylinder ports<br />
in valve<br />
plug-in<br />
plug-in<br />
with F. C.<br />
plug-in<br />
with Pr. Reg.<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
add-on style<br />
plug-in<br />
add-on style<br />
plug-in<br />
with F. C.<br />
add-on style<br />
plug-in<br />
with Pr. Reg.<br />
add-on style<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
plug-in<br />
add-a-unit<br />
stations<br />
plug-in<br />
add-a-unit<br />
stations<br />
with F. C.<br />
plug-in<br />
add-a-unit<br />
stations<br />
with Pr. Reg.<br />
plug-in<br />
add-a-unit<br />
stations with<br />
F. C. <strong>and</strong> Pr. Reg.<br />
plug-in with<br />
pre-wired<br />
connector<br />
plug-in with<br />
F. C. <strong>and</strong><br />
pre-wired<br />
connector<br />
plug-in with<br />
Pr. Reg. <strong>and</strong><br />
pre-wired<br />
connector<br />
din rail,<br />
plug-in with<br />
pre-wired<br />
connector<br />
din rail,<br />
plug-in with<br />
F. C. <strong>and</strong> prewired<br />
connector<br />
Manual operator<br />
Armature<br />
Coil<br />
Push pin<br />
Poppet<br />
“D” seal<br />
Valve spring<br />
SERIES FEATURES<br />
• High force MACSOLENOID ® .<br />
• Universal porting.<br />
• #10-32 or M5 ports.<br />
• Rated for lubricated or non-lubricated service.<br />
• 10mm direct operated.<br />
• Cylinder port in valve or in circuit bar.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.11C v<br />
non plug-in<br />
cylinder ports<br />
in base<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-Gxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Pressure range : 0 to 120 PSI<br />
1 3<br />
34B-LOO-GXXX-XXX<br />
1 3<br />
34B-NOO-GXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
A 18”<br />
1 Non-locking<br />
KA<br />
Mini connector<br />
DD 24VDC (2.5 W)<br />
C 36”<br />
KT<br />
Mini connector<br />
with light<br />
DF 24VDC (4.0 W)<br />
xx Other Options<br />
x<br />
Other Options<br />
BA<br />
BT<br />
xx<br />
Flying leads<br />
Flying leads with light<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
EBP34B-xxxx-xx<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
M5<br />
# 10-32<br />
EBP34B-001D-XX<br />
EBP34B-001B-XX<br />
EBP34B-002D-XX<br />
EBP34B-002B-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
1.8 mm<br />
4 W : 0.11C v , 2.5 W : 0.084C v , 1.8 W : 0.061C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 3.4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory.<br />
DIMENSIONS<br />
1/8” - NPT PORTS 1 & 3<br />
EACH END<br />
59,0<br />
52,0<br />
C L C L C L<br />
2<br />
1<br />
6,0<br />
22,0<br />
12,5<br />
3<br />
7,5<br />
2,0<br />
10,5 18,0<br />
4,5<br />
4,0<br />
14,5<br />
12,5<br />
14,0<br />
34,0<br />
18,0<br />
34,0<br />
OPTIONAL BOTTOM<br />
PORTS<br />
18,0<br />
4,5<br />
4,2 DIA.<br />
MOUNTING HOLES<br />
4,0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting<br />
3/2 NO-NC # 10-32 - 1/8“ 0.11C v<br />
non plug-in<br />
cylinder ports<br />
in valve<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-Gxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Valve port size<br />
Universal valve<br />
NC only valve<br />
2<br />
2<br />
M5<br />
# 10-32<br />
1 3<br />
34B-ABA-GXXX-XXX<br />
34B-AAA-GXXX-XXX<br />
1 3<br />
34B-ABB-GXXX-XXX<br />
34B-AAB-GXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
A 18”<br />
1 Non-locking<br />
KA<br />
Mini connector<br />
DD 24VDC (2.5 W)<br />
C 36”<br />
KT<br />
Mini connector<br />
with light<br />
DF 24VDC (4.0 W)<br />
xx Other Options<br />
x<br />
Other Options<br />
BA<br />
BT<br />
xx<br />
Flying leads<br />
Flying leads with light<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
EBM34A-xxxx-xx<br />
Port size<br />
COMMON INLET & EXHAUST<br />
# 10-32<br />
1/8” NPTF<br />
EBM34A-001B-XX<br />
EBM34A-002A-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.11C v , 2.5 W : 0.084C v , 1.8 W : 0.061C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 3.4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve fastening kit : M34001-01 (1/8” Bar); M34001-21 (#10-32 Bar) • Blanking plate : 30456-A.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory.<br />
DIMENSIONS<br />
19,0<br />
2<br />
B<br />
1<br />
3<br />
A<br />
G<br />
D<br />
10,5<br />
E<br />
14,0<br />
F<br />
C<br />
38,5<br />
Port size<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
1/8”<br />
16.0<br />
47.5<br />
57.4<br />
8.0<br />
23.0<br />
31.0<br />
8.0<br />
M5<br />
12.0<br />
43.5<br />
51.5<br />
9.0<br />
18.0<br />
26.0<br />
6.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v plug-in<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
ECD034B-00xxx-AOxx<br />
Port size<br />
Side cylinder ports<br />
(10.5 mm)<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
M5<br />
ECD034B-001AD-AOXX<br />
ECD034B-002AD-AOXX<br />
# 10-32<br />
ECD034B-001AB-AOXX<br />
ECD034B-002AB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector option (9, 15 or 25).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
32.0<br />
TYP<br />
20.0<br />
8.3<br />
TYP<br />
29.5<br />
14.7<br />
TYP<br />
3<br />
TYP<br />
83.8<br />
57.2<br />
1<br />
77.0<br />
TYP<br />
2 2 2 2<br />
23.3<br />
10.5<br />
60.80<br />
22.3<br />
25.5<br />
TYP<br />
2 2 2 2<br />
10.0<br />
24.8<br />
10.5<br />
4.5<br />
10.0<br />
20.2<br />
22.5<br />
33.0<br />
21.6<br />
23.9<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
55.5<br />
3<br />
66.0<br />
4<br />
76.5<br />
5<br />
87.0<br />
6<br />
97.5<br />
7 8 9 10<br />
108.0 118.5 129.0 139.5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v<br />
plug-in<br />
with F. C.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />
Port size<br />
M5<br />
# 10-32<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECD034B-005AD-AOXX<br />
ECD034B-005AB-AOXX<br />
ECD034B-00xxx-AOxx<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECD034B-006AD-AOXX<br />
ECD034B-006AB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector option (9, 15 or 25).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
32.0<br />
TYP<br />
20.0<br />
8.3<br />
TYP<br />
14.7<br />
TYP<br />
29.5<br />
TYP<br />
3<br />
10.2<br />
83.8<br />
57.2<br />
1<br />
77.0<br />
TYP<br />
2 2 2 2<br />
23.3<br />
22.3<br />
34.40<br />
25.8<br />
TYP<br />
10.5<br />
60.80<br />
10.0<br />
24.8<br />
10.5<br />
4.5<br />
10.0<br />
20.2<br />
2 2 2 2<br />
22.5<br />
33.0<br />
21.6<br />
23.9<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
55.5<br />
3<br />
66.0<br />
4<br />
76.5<br />
5<br />
87.0<br />
6<br />
97.5<br />
7 8 9 10<br />
108.0 118.5 129.0 139.5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v<br />
plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />
ECD034B-00xxx-AOxx<br />
Port size<br />
M5<br />
# 10-32<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECD034B-004AD-AOXX<br />
ECD034B-004AB-AOXX<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECD034B-003AD-AOXX<br />
ECD034B-003AB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector option (9, 15 or 25).<br />
** Pressure Regulators :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Blanking plate for regulator : N-44003. • Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
40.00<br />
L<br />
32.0<br />
TYP<br />
24.8<br />
10.5<br />
20.2<br />
8.3<br />
TYP<br />
144.1<br />
14.7<br />
TYP<br />
29.5<br />
3<br />
2 2 2 2<br />
23.3<br />
TYP<br />
83.8<br />
57.2<br />
1<br />
22.3<br />
77.0<br />
TYP<br />
10.0<br />
4.5<br />
10.0<br />
10.5<br />
20.0<br />
60.80<br />
25.8<br />
TYP<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
2 2 2 2<br />
22.5<br />
33.0<br />
21.6<br />
23.9<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
55.5<br />
3<br />
66.0<br />
4<br />
76.5<br />
5<br />
87.0<br />
6<br />
97.5<br />
7 8 9 10<br />
108.0 118.5 129.0 139.5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.09C v<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
ECD034B-00xxx-AOxx<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS ** (pressure regulators to be ordered separately)<br />
Port size<br />
M5<br />
# 10-32<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECD034B-007AD-AOXX<br />
ECD034B-007AB-AOXX<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECD034B-008AD-AOXX<br />
ECD034B-008AB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector option (9, 15 or 25).<br />
** Pressure Regulators :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180. • Blanking plate for regulator : N-44003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
40.00<br />
L<br />
32.0<br />
TYP<br />
24.8<br />
10.5<br />
20.2<br />
8.3<br />
TYP<br />
144.1<br />
29.5<br />
14.7<br />
TYP<br />
3<br />
2 2 2 2<br />
23.3<br />
TYP<br />
83.8<br />
57.2<br />
1<br />
22.3<br />
77.0<br />
TYP<br />
10.0<br />
4.5<br />
10.0<br />
10.5<br />
20.0<br />
60.80<br />
25.8<br />
TYP<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
2 2 2 2<br />
22.5<br />
33.0<br />
21.6<br />
23.9<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
55.5<br />
3<br />
66.0<br />
4<br />
76.5<br />
5<br />
87.0<br />
6<br />
97.5<br />
7 8 9 10<br />
108.0 118.5 129.0 139.5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v<br />
add-on style<br />
plug-in<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
ECD034B-00xxx-AOxx<br />
Port size<br />
Side cylinder ports<br />
(10.5 mm)<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
M5<br />
ECD034B-001BD-AOXX<br />
ECD034B-002BD-AOXX<br />
# 10-32<br />
ECD034B-001BB-AOXX<br />
ECD034B-002BB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector option (9, 15 or 25).<br />
add-a-unit stations may be added to above bars. Clic here for model numbers.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
32.0<br />
20.0<br />
8.3<br />
14.8<br />
29.5<br />
3<br />
83.7<br />
57.2<br />
1<br />
77.0<br />
2 2 2 2<br />
15.0<br />
10.5 16.0<br />
15.5<br />
60.8<br />
23.0<br />
22.3<br />
4.5<br />
10.0<br />
25.3<br />
41.3<br />
10.9<br />
25.8<br />
2 2 2 2<br />
20.2<br />
10.5<br />
22.5<br />
33.0<br />
23.0<br />
25.3<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
57.0<br />
3<br />
67.5<br />
4<br />
78.0<br />
5<br />
88.5<br />
6<br />
99.0<br />
7 8 9 10<br />
109.5 120.0 130.5 141.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v<br />
add-on style<br />
plug-in<br />
with F. C.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />
Port size<br />
M5<br />
# 10-32<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECD034B-005BD-AOXX<br />
ECD034B-005BB-AOXX<br />
ECD034B-00xxx-AOxx<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECD034B-006BD-AOXX<br />
ECD034B-006BB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector option (9, 15 or 25).<br />
add-a-unit stations may be added to above bars. Clic here for model numbers.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
32.0<br />
20.0<br />
8.3<br />
14.8<br />
29.5<br />
3<br />
83.7<br />
57.2<br />
1<br />
77.0<br />
2 2 2 2<br />
15.5<br />
15.0<br />
10.5 16.0<br />
60.8<br />
25.8<br />
2 2 2 2<br />
23.0<br />
22.3<br />
4.5<br />
10.0<br />
25.3<br />
41.3<br />
10.9<br />
10.5<br />
20.2<br />
22.5<br />
33.0<br />
23.0<br />
25.3<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
57.0<br />
3<br />
67.5<br />
4<br />
78.0<br />
5<br />
88.5<br />
6<br />
99.0<br />
7 8 9 10<br />
109.5 120.0 130.5 141.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v<br />
add-on style<br />
plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
ECD034B-00xxx-AOxx<br />
HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />
Port size<br />
M5<br />
# 10-32<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECD034B-004BD-AOXX<br />
ECD034B-004BB-AOXX<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECD034B-003BD-AOXX<br />
ECD034B-003BB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector option (9, 15 or 25).<br />
add-a-unit stations may be added to above bars. Clic here for model numbers.<br />
** Pressure Regulators :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180. • Blanking plate for regulator : N-44003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
32.0<br />
L<br />
20.0<br />
20.2 10.5<br />
41.3<br />
25.3<br />
14.8<br />
29.5<br />
57.2<br />
8.3<br />
1<br />
3<br />
83.7<br />
2 2 2 2<br />
77.0<br />
137.3<br />
10.5<br />
15.0<br />
16.0<br />
15.5<br />
60.8<br />
4.5<br />
22.3<br />
23.0 10.0<br />
10.9<br />
25.8<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
2 2 2 2<br />
22.5<br />
33.0<br />
23.0<br />
25.3<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
57.0<br />
3<br />
67.5<br />
4<br />
78.0<br />
5<br />
88.5<br />
6<br />
99.0<br />
7 8 9 10<br />
109.5 120.0 130.5 141.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.09C v<br />
plug-in<br />
with Pr. Reg.<br />
add-on style<br />
<strong>and</strong> F. C.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
ECD034B-00xxx-AOxx<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS ** (pressure regulators to be ordered separately)<br />
Port size<br />
M5<br />
# 10-32<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECD034B-007BD-AOXX<br />
ECD034B-007BB-AOXX<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECD034B-008BD-AOXX<br />
ECD034B-008BB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector option (9, 15 or 25).<br />
add-a-unit stations may be added to above bars. Clic here for model numbers.<br />
** Pressure Regulators :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Blanking plate for regulator : N-44003. • Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
32.0<br />
20.0<br />
20.2<br />
10.5<br />
41.3<br />
25.3<br />
14.8<br />
29.5<br />
57.2<br />
8.3<br />
83.7<br />
1<br />
3<br />
2 2 2 2<br />
77.0<br />
137.3<br />
15.5<br />
23.0<br />
22.3<br />
10.0<br />
4.5<br />
10.9<br />
15.0<br />
10.5 16.0<br />
60.8<br />
25.8<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
2 2 2 2<br />
22.5<br />
33.0<br />
23.0<br />
25.3<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
57.0<br />
3<br />
67.5<br />
4<br />
78.0<br />
5<br />
88.5<br />
6<br />
99.0<br />
7 8 9 10<br />
109.5 120.0 130.5 141.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v<br />
plug-in<br />
add-a-unit<br />
stations<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
ECD034B-00xxx-AOxx<br />
Port size<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
M5<br />
ECD034B-001CD-AOXX<br />
ECD034B-002CD-AOXX<br />
# 10-32<br />
ECD034B-001CB-AOXX<br />
ECD034B-002CB-AOXX<br />
Number of stations (03=3 stations) - Maximum length is 4 stations<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
when add-a-unit stations are added to bars with a multi-pin connector,<br />
MOD. SD03 should be included with add-a-unit model number.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
32.0<br />
20.0<br />
8.3<br />
14.8<br />
29.5<br />
3<br />
83.7<br />
57.2<br />
1<br />
77.0<br />
2 2 2 2<br />
15.0<br />
10.5 16.0<br />
15.5<br />
60.8<br />
23.0<br />
22.3<br />
4.5<br />
10.0<br />
25.3<br />
41.3<br />
10.9<br />
25.8<br />
2 2 2 2<br />
20.2<br />
10.5<br />
22.5<br />
33.0<br />
23.0<br />
25.3<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
57.0<br />
3<br />
67.5<br />
4<br />
78.0<br />
5<br />
88.5<br />
6<br />
99.0<br />
7 8 9 10<br />
109.5 120.0 130.5 141.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v<br />
add-a-unit<br />
stations with<br />
plug-in<br />
F. C.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />
Port size<br />
Side cylinder ports<br />
ECD034B-00xxx-AOxx<br />
Bottom cylinder ports<br />
M5<br />
# 10-32<br />
ECD034B-005CD-AOXX<br />
ECD034B-005CB-AOXX<br />
ECD034B-006CD-AOXX<br />
ECD034B-006CB-AOXX<br />
Number of stations (03=3 stations) - Maximum length is 4 stations<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
when add-a-unit stations are added to bars with a multi-pin connector,<br />
MOD. SD03 should be included with add-a-unit model number.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
32.0<br />
20.0<br />
8.3<br />
14.8<br />
29.5<br />
3<br />
83.7<br />
57.2<br />
1<br />
77.0<br />
2 2 2 2<br />
15.5<br />
15.0<br />
10.5 16.0<br />
60.8<br />
25.8<br />
2 2 2 2<br />
23.0<br />
22.3<br />
4.5<br />
10.0<br />
25.3<br />
41.3<br />
10.9<br />
10.5<br />
20.2<br />
22.5<br />
33.0<br />
23.0<br />
25.3<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
57.0<br />
3<br />
67.5<br />
4<br />
78.0<br />
5<br />
88.5<br />
6<br />
99.0<br />
7 8 9 10<br />
109.5 120.0 130.5 141.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v<br />
add-a-unit<br />
stations<br />
plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DD 24VDC (2.5 W)<br />
DF 24VDC (4.0 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />
DJ Plug-in<br />
DT Plug-in with light<br />
DE Plug-in with suppression diode<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
ECD034B-00xxx-AOxx<br />
Port size<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
M5<br />
# 10-32<br />
ECD034B-003CD-AOXX<br />
ECD034B-003CB-AOXX<br />
ECD034B-004CD-AOXX<br />
ECD034B-004CB-AOXX<br />
Number of stations (03=3 stations) - Maximum length is 4 stations<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
when add-a-unit stations are added to bars with a multi-pin connector,<br />
MOD. SD03 should be included with add-a-unit model number.<br />
** Regulator ordered separately-see below<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180. • Blanking plate for regulator : N-44003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
32.0<br />
L<br />
20.0<br />
20.2 10.5<br />
41.3<br />
25.3<br />
14.8<br />
29.5<br />
57.2<br />
8.3<br />
1<br />
3<br />
83.7<br />
2 2 2 2<br />
77.0<br />
137.3<br />
10.5<br />
15.0<br />
16.0<br />
15.5<br />
60.8<br />
4.5<br />
22.3<br />
23.0 10.0<br />
10.9<br />
25.8<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
2 2 2 2<br />
22.5<br />
33.0<br />
23.0<br />
25.3<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
57.0<br />
3<br />
67.5<br />
4<br />
78.0<br />
5<br />
88.5<br />
6<br />
99.0<br />
7 8 9 10<br />
109.5 120.0 130.5 141.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v<br />
add-a-unit<br />
stations with<br />
plug-in<br />
F. C. <strong>and</strong> Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ Plug-in<br />
DD 24VDC (2.5 W)<br />
DT Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE Plug-in with suppression diode<br />
xx Other Options<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
ECD034B-00xxx-AOxx<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS ** (pressure regulators to be ordered separately)<br />
Port size<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
M5<br />
# 10-32<br />
ECD034B-008CD-AOXX<br />
ECD034B-008CB-AOXX<br />
ECD034B-007CD-AOXX<br />
ECD034B-007CB-AOXX<br />
Number of stations (03=3 stations) - Maximum length is 4 stations<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
when add-a-unit stations are added to bars with a multi-pin connector,<br />
MOD. SD03 should be included with add-a-unit model number.<br />
** Regulator ordered separately-see below<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Blanking plate for regulator : N-44003. • Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
32.0<br />
20.0<br />
20.2<br />
10.5<br />
41.3<br />
25.3<br />
14.8<br />
29.5<br />
57.2<br />
8.3<br />
83.7<br />
1<br />
3<br />
2 2 2 2<br />
77.0<br />
137.3<br />
15.5<br />
23.0<br />
22.3<br />
10.0<br />
4.5<br />
10.9<br />
15.0<br />
10.5 16.0<br />
60.8<br />
25.8<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
2 2 2 2<br />
22.5<br />
33.0<br />
23.0<br />
25.3<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
57.0<br />
3<br />
67.5<br />
4<br />
78.0<br />
5<br />
88.5<br />
6<br />
99.0<br />
7 8 9 10<br />
109.5 120.0 130.5 141.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32, 0.11C v<br />
4mm tube receptacle<br />
plug-in with<br />
pre-wired<br />
connector<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
ECF34B-00xxx-xxxx<br />
Port size<br />
Side cylinder ports<br />
(10.5 mm)<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
M5<br />
ECF34B-00ADA-ZZXX<br />
ECF34B-00BDA-ZZXX<br />
# 10-32<br />
ECF34B-00ABA-ZZXX<br />
ECF34B-00BBA-ZZXX<br />
4 mm tube receptacle<br />
ECF34B-00AEA-ZZXX<br />
---------<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
ZZ Connector<br />
LA 9 Pin Sub D*<br />
LB 15 Pin Sub D*<br />
LC 25 Pin Sub D*<br />
LD 10 Pin Ribbon Cable**<br />
LE 16 Pin Ribbon Cable**<br />
LF 20 Pin Ribbon Cable**<br />
LG 26 Pin Ribbon Cable**<br />
LH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
L=Left Side; R=Right Side<br />
ZZ Connector<br />
RA 9 Pin Sub D*<br />
RB 15 Pin Sub D*<br />
RC 25 Pin Sub D*<br />
RD 10 Pin Ribbon Cable**<br />
RE 16 Pin Ribbon Cable**<br />
RF 20 Pin Ribbon Cable**<br />
RG 26 Pin Ribbon Cable**<br />
RH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
* MIL. Spec; MIL-C-24308<br />
** MIL. Spec; MIL-C-83503<br />
Note: Left <strong>and</strong> right end is determined by facing conduit passage.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
72.6<br />
9.0<br />
17.4<br />
16.7<br />
3<br />
37.9<br />
1<br />
20.0<br />
10.5 13.0<br />
5.0<br />
26.8<br />
53.5 2 2 2<br />
51.6<br />
88.7<br />
2<br />
20.2<br />
10.5<br />
10.0<br />
2 2 2<br />
2<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32, 0.11C v<br />
4mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
plug-in with<br />
F. C. <strong>and</strong><br />
pre-wired<br />
connector<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />
Port size<br />
M5<br />
# 10-32<br />
4 mm tube receptacle<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECF34B-00CDA-ZZXX<br />
ECF34B-00CBA-ZZXX<br />
ECF34B-00CEA-ZZXX<br />
ECF34B-00xxx-xxxx<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECF34B-00DDA-ZZXX<br />
ECF34B-00DBA-ZZXX<br />
---------<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
ZZ Connector<br />
LA 9 Pin Sub D*<br />
LB 15 Pin Sub D*<br />
LC 25 Pin Sub D*<br />
LD 10 Pin Ribbon Cable**<br />
LE 16 Pin Ribbon Cable**<br />
LF 20 Pin Ribbon Cable**<br />
LG 26 Pin Ribbon Cable**<br />
LH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
L=Left Side; R=Right Side<br />
ZZ Connector<br />
RA 9 Pin Sub D*<br />
RB 15 Pin Sub D*<br />
RC 25 Pin Sub D*<br />
RD 10 Pin Ribbon Cable**<br />
RE 16 Pin Ribbon Cable**<br />
RF 20 Pin Ribbon Cable**<br />
RG 26 Pin Ribbon Cable**<br />
RH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
* MIL. Spec; MIL-C-24308<br />
** MIL. Spec; MIL-C-83503<br />
Note: Left <strong>and</strong> right end is determined by facing conduit passage.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.11C v , 2.5 W : 0.09C v , 1.8 W : 0.06C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
9.0 17.4<br />
16.7<br />
3<br />
80.1<br />
37.9<br />
1<br />
20.0<br />
10.5<br />
13.0<br />
5.0<br />
26.8<br />
53.5<br />
88.7<br />
51.6<br />
2 2<br />
2<br />
2<br />
20.2 10.5<br />
10.0<br />
2<br />
2<br />
2<br />
2<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32 0.10C v<br />
Pr. Reg. <strong>and</strong><br />
pre-wired<br />
plug-in with<br />
connector<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />
Port size<br />
M5<br />
# 10-32<br />
ECF34B-00xxx-xxxx<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECF34B-00EDA-ZZXX<br />
ECF34B-00EBA-ZZXX<br />
Number of stations (03=3 stations)<br />
** Pressure Regulators :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
ZZ<br />
Connector<br />
LA 9 Pin Sub D*<br />
LB 15 Pin Sub D*<br />
LC 25 Pin Sub D*<br />
LD 10 Pin Ribbon Cable**<br />
LE 16 Pin Ribbon Cable**<br />
LF 20 Pin Ribbon Cable**<br />
LG 26 Pin Ribbon Cable**<br />
LH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
L=Left Side; R=Right Side<br />
ZZ Connector<br />
RA 9 Pin Sub D*<br />
RB 15 Pin Sub D*<br />
RC 25 Pin Sub D*<br />
RD 10 Pin Ribbon Cable**<br />
RE 16 Pin Ribbon Cable**<br />
RF 20 Pin Ribbon Cable**<br />
RG 26 Pin Ribbon Cable**<br />
RH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
* MIL. Spec; MIL-C-24308<br />
** MIL. Spec; MIL-C-83503<br />
Note: Left <strong>and</strong> right end is determined by facing conduit passage.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Blanking plate for regulator : N-44003. • Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
132.9<br />
9.0 17.4<br />
16.7<br />
3<br />
1<br />
37.9<br />
20.0<br />
5.0<br />
26.8<br />
53.5<br />
88.7<br />
51.6<br />
2 2<br />
2<br />
2<br />
K<br />
O C<br />
L<br />
K<br />
O C<br />
L<br />
K<br />
O C<br />
L<br />
K<br />
O C<br />
L<br />
2<br />
-<br />
+<br />
-<br />
+<br />
-<br />
+<br />
-<br />
+<br />
10.5<br />
13.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32, 0.11C v<br />
4mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
din rail,<br />
plug-in with<br />
pre-wired<br />
connector<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
ECF34B-00xxx-xxxx<br />
Port size<br />
M5<br />
# 10-32<br />
4 mm tube receptacle<br />
Number of stations (03=3 stations)<br />
Din rail spec. (EN50 022)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
ZZ<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECF34B-00ADB-ZZXX<br />
ECF34B-00ABB-ZZXX<br />
ECF34B-00AEB-ZZXX<br />
Connector<br />
LA 9 Pin Sub D*<br />
LB 15 Pin Sub D*<br />
LC 25 Pin Sub D*<br />
LD 10 Pin Ribbon Cable**<br />
LE 16 Pin Ribbon Cable**<br />
LF 20 Pin Ribbon Cable**<br />
LG 26 Pin Ribbon Cable**<br />
LH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
L=Left Side; R=Right Side<br />
ZZ Connector<br />
RA 9 Pin Sub D*<br />
RB 15 Pin Sub D*<br />
RC 25 Pin Sub D*<br />
RD 10 Pin Ribbon Cable**<br />
RE 16 Pin Ribbon Cable**<br />
RF 20 Pin Ribbon Cable**<br />
RG 26 Pin Ribbon Cable**<br />
RH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
* MIL. Spec; MIL-C-24308<br />
** MIL. Spec; MIL-C-83503<br />
Note: Left <strong>and</strong> right end is determined by facing conduit passage.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
2<br />
3<br />
1<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.11C v , 2.5 W : 0.09C v , 1.8 W : 0.06C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
72.6<br />
9.0<br />
17.4<br />
3<br />
16.7<br />
1<br />
37.9<br />
VAC TO 120 PSI<br />
ELECTRICAL WATTS<br />
MODEL<br />
WIXOM,MI.USA<br />
LIEGE,BELGIUM<br />
AUCKLAND,N.Z.<br />
20.0<br />
5.0<br />
MODIF.<br />
53.5<br />
88.7<br />
60.9<br />
20.2<br />
10.5<br />
10.0<br />
2 2 2 2<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 34<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC M5 - #10-32, 0.11C v<br />
4 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
din rail,<br />
plug-in with<br />
F. C. <strong>and</strong> prewired<br />
connector<br />
HOW TO ORDER<br />
34B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
34B-LOO-GXXO-XXX<br />
1 3<br />
34B-NOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DJ<br />
Plug-in<br />
DD 24VDC (2.5 W)<br />
DT<br />
Plug-in with light<br />
DF 24VDC (4.0 W)<br />
DE<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
DV<br />
xx<br />
Plug-in with light <strong>and</strong> suppression diode<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />
Port size<br />
M5<br />
# 10-32<br />
4 mm tube receptacle<br />
Number of stations (03=3 stations)<br />
Din rail spec. (EN50 022)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
ZZ<br />
ECF34B-00xxx-xxxx<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECF34B-00CDB-ZZXX<br />
ECF34B-00CBB-ZZXX<br />
ECF34B-00CEB-ZZXX<br />
Connector<br />
LA 9 Pin Sub D*<br />
LB 15 Pin Sub D*<br />
LC 25 Pin Sub D*<br />
LD 10 Pin Ribbon Cable**<br />
LE 16 Pin Ribbon Cable**<br />
LF 20 Pin Ribbon Cable**<br />
LG 26 Pin Ribbon Cable**<br />
LH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
L=Left Side; R=Right Side<br />
ZZ Connector<br />
RA 9 Pin Sub D*<br />
RB 15 Pin Sub D*<br />
RC 25 Pin Sub D*<br />
RD 10 Pin Ribbon Cable**<br />
RE 16 Pin Ribbon Cable**<br />
RF 20 Pin Ribbon Cable**<br />
RG 26 Pin Ribbon Cable**<br />
RH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
* MIL. Spec; MIL-C-24308<br />
** MIL. Spec; MIL-C-83503<br />
Note: Left <strong>and</strong> right end is determined by facing conduit passage.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
2<br />
3<br />
1<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 34<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.11C v , 2.5 W : 0.09C v , 1.8 W : 0.06C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
9.0 17.4<br />
80.1<br />
16.7<br />
3<br />
1<br />
37.9<br />
VAC TO 120 PSI<br />
ELECTRICAL<br />
WATTS<br />
MODEL<br />
WIXOM,MI.USA MODIF.<br />
LIEGE,BELGIUM<br />
AUCKLAND,N.Z.<br />
20.0<br />
5.0<br />
53.5<br />
88.7<br />
60.9<br />
20.2 10.5<br />
10.0<br />
2<br />
2<br />
2<br />
2<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Section 2 Options<br />
Consult “Precautions” before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Codification table for voltages / Manual operator / Electrical connection<br />
VALVE CODE ➤<br />
- G XX X - X XX<br />
1 2 3 4<br />
OPTIONS AVAILABLE FOR<br />
- solenoid valves 34 & 44 Series<br />
Consult “Precautions”before use, installation or service of MAC Valves.
OPTIONS<br />
Back<br />
1. VOLTAGE (type 34 Series)<br />
-G XX X - X XX VOLTAGE<br />
DC 24 VDC (1,8 W)<br />
DD 24 VDC (2,5 W)<br />
DE 24 VDC (3,0 W)<br />
DF 24 VDC (4,0 W)<br />
DJ 12 VDC (1,8 W)<br />
DK 12 VDC (2,5 W)<br />
DM 12 VDC (3,0 W)<br />
DN 12 VDC (4,0 W)<br />
1. VOLTAGE (type 44 Series)<br />
-G XX X - X XX VOLTAGE<br />
DA 24 VDC (1,0 W)<br />
DC 24 VDC (1,8 W)<br />
DD 24 VDC (2,5 W)<br />
DF 24 VDC (4,0 W)<br />
DG 12 VDC (1,0 W)<br />
DJ 12 VDC (1,8 W)<br />
DK 12 VDC (2,5 W)<br />
DN 12 VDC (4,0 W)<br />
2. WIRE LENGTH (Common options for 34 & 44 Series)<br />
-G XX X - X XX WIRE LENGTH<br />
A 18”<br />
B 24”<br />
C 36”<br />
D 48”<br />
E 72”<br />
F 96”<br />
G 120”<br />
H 144”<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Back<br />
3. MANUAL OPERATOR (COMMON OPTIONS FOR 34 & 44 SERIES)<br />
-G XX X - X XX MANUAL OPERATOR<br />
1 Non-locking recessed<br />
3 Non-locking extended<br />
4. ELECTRICAL CONNECTION (COMMON OPTIONS FOR 34 & 44 SERIES)<br />
-G XX X - X XX NO CONNECTOR<br />
BA Flying leads<br />
BB BA with ground wire<br />
BC BA with light<br />
BD BA with light <strong>and</strong> ground wire<br />
BE BA with suppression diode<br />
BF BA with suppression diode <strong>and</strong> ground wire<br />
BG BA with suppression diode <strong>and</strong> light<br />
BH BA with suppression diode, light <strong>and</strong> ground wire<br />
BN BA with suppression diode <strong>and</strong> blocking diode<br />
BP BA with suppression diode, blocking diode <strong>and</strong> ground wire<br />
BR BA with suppression diode, blocking diode <strong>and</strong> light<br />
BS BA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />
BT BA with light<br />
BU BA with light <strong>and</strong> ground wire<br />
BV BA with suppression diode <strong>and</strong> light<br />
BW BA with suppression diode, light <strong>and</strong> ground wire<br />
BX BA with suppression diode, blocking diode <strong>and</strong> light<br />
BY BA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />
-G XX X - X XX PLUG-IN CONNECTOR<br />
KA Mini connector with flying leads<br />
KB KA with ground wire<br />
KE KA with suppression diode<br />
KF KA with suppression diode <strong>and</strong> ground wire<br />
KJ Mini connector for KA option<br />
KM Mini connector for KB option<br />
KN KA with suppression diode <strong>and</strong> blocking diode<br />
KP KA with suppression diode, blocking diode <strong>and</strong> ground wire<br />
KT KA with light<br />
KU KA with light <strong>and</strong> ground wire<br />
KV KA with suppression diode <strong>and</strong> light<br />
KW KA with suppression diode, light <strong>and</strong> ground wire<br />
KX KA with suppression diode, blocking diode <strong>and</strong> light<br />
KY KA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
PIN #6<br />
PIN #9<br />
MOD. SD09<br />
PIN #1<br />
PIN #5<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 9<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 7 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 2 common wires<br />
PIN #9<br />
PIN #15<br />
MOD. SD15<br />
PIN #1<br />
PIN #8<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 15<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 12 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 3 common wires<br />
PIN #14<br />
PIN #25<br />
MOD. SD25<br />
PIN #1<br />
PIN #13<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 25<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 20 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 5 common wires<br />
Note : Use desired MOD. number after circuit bar part number
O p t i o n s<br />
OPTIONS<br />
Connector termination details<br />
CONNECTOR<br />
SOL 1<br />
SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />
Single solenoid circuit bar<br />
SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />
CONNECTOR<br />
SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />
Double solenoid circuit bar<br />
SD09 SD15 SD25<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
8<br />
COMMON (+)<br />
13<br />
COMMON (+)<br />
21<br />
COMMON (+)<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
9<br />
COMMON (+)<br />
8<br />
SOL. 8<br />
8<br />
SOL. 8<br />
14<br />
COMMON (+)<br />
22<br />
COMMON (+)<br />
9<br />
SOL. 9<br />
9<br />
SOL. 9<br />
10 SOL. 10<br />
10 SOL. 10<br />
11<br />
SOL. 11<br />
11<br />
SOL. 11<br />
12 SOL. 12<br />
12 SOL. 12<br />
15<br />
COMMON (+)<br />
23<br />
COMMON (+)<br />
13<br />
SOL. 13<br />
14 SOL. 14<br />
15<br />
SOL. 15<br />
16 SOL. 16<br />
24<br />
COMMON (+)<br />
17<br />
18 SOL. 18<br />
19<br />
20 SOL. 20<br />
SOL. 17<br />
SOL. 19<br />
25<br />
COMMON (+)
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 35<br />
Circuit bar mounting<br />
non plug-in<br />
non plug-in<br />
with Pr. Reg.<br />
plug-in<br />
plug-in<br />
with side<br />
Pr. Reg.<br />
plug-in<br />
with integral<br />
terminal strip<br />
plug-in with<br />
integral terminal<br />
strip <strong>and</strong> side<br />
Pr. Reg.<br />
Manual operator<br />
Armature<br />
Epoxy encapsulated solenoid<br />
Push pin<br />
Spring biased moveable pole piece<br />
1<br />
Bonded balanced poppet<br />
CYL.<br />
PORT<br />
2<br />
N.C.<br />
PORT<br />
Spring return<br />
3<br />
SERIES FEATURES<br />
• Patented MACSOLENOID ® for fastest possible response times.<br />
• Balanced poppet permits versatility in function :<br />
- 3 way N.C. - 3 way N.O. - Divertor - Selector<br />
• Extremely high cycle rate capability.<br />
• Various solenoid enclosures <strong>and</strong> plug-in connectors.<br />
• Low wattage DC solenoids - down to 1.8 watts.<br />
• Rated for lubricated or non-lubricated service.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 35<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v non plug-in<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
35A-xxx-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Universal valve<br />
CYL<br />
Valve less base<br />
IN EXH<br />
35A-B00-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
AA 120/60, 110/50<br />
A<br />
18” (Flying leads)<br />
1 Non-locking Recessed<br />
KA<br />
Square connector<br />
AB 240/60, 220/50<br />
J<br />
Connector<br />
2 Locking Recessed<br />
KD<br />
Square connector<br />
with light<br />
AC 24/60, 24/50<br />
x<br />
Other Options<br />
x<br />
Other Options<br />
BA<br />
Flying leads<br />
FB 24VDC (1.8 W)<br />
xx<br />
Other Options<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR**<br />
Port size<br />
1/8” NPTF<br />
# 10-32 UNF<br />
EBM35A-xxxx-xx<br />
Side cylinder ports<br />
Spacing 21 mm<br />
EBM35A-001A-XX<br />
EBM35A-001B-XX<br />
Bottom cylinder ports<br />
Spacing 21 mm<br />
EBM35A-002A-XX<br />
EBM35A-002B-XX<br />
Number of stations (03=3 stations)<br />
* * Other options available. Consult factory.<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 35<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
VALVE BLANKING<br />
PLATE<br />
21,0<br />
"A"<br />
21,0<br />
5,2 DIA.<br />
2 MTG. HOLES<br />
D<br />
7,0<br />
21,0<br />
5,0<br />
OPTIONAL<br />
BOTTOM PORTS<br />
5,0<br />
29,5<br />
2 2<br />
5,0<br />
B<br />
64,5<br />
32,5<br />
26,3<br />
50,5<br />
22,0<br />
11,5<br />
SPACING SIZE<br />
A<br />
17,0<br />
32,0<br />
40,0<br />
1/8” 2 PORTS<br />
BOTH ENDS<br />
STANDARD<br />
FOR JB<br />
SPACING SIZE<br />
21.0<br />
26.0<br />
B D<br />
1/8”<br />
# 10-32<br />
8.0<br />
5.5<br />
24.5<br />
24.2<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 35<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v<br />
non plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
35A-xxx-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Universal valve<br />
CYL<br />
Valve less base<br />
Valve less base w/ gage port<br />
IN EXH<br />
35A-B00-DXXX-XXX<br />
35A-F00-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
AA 120/60, 110/50<br />
A<br />
18” (Flying leads)<br />
1 Non-locking Recessed<br />
KA<br />
Square connector<br />
AB 240/60, 220/50<br />
J<br />
Connector<br />
2 Locking Recessed<br />
KD<br />
Square connector<br />
with light<br />
AC 24/60, 24/50<br />
x<br />
Other Options<br />
x<br />
Other Options<br />
BA<br />
Flying leads<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
xx<br />
Other Options<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
EBM35A-xxxx-xx<br />
HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY)* *<br />
Port size<br />
Side cylinder ports<br />
Spacing 21 mm<br />
Spacing 40 mm<br />
1/8” NPTF<br />
# 10-32 UNF<br />
Port size<br />
Bottom cylinder ports<br />
EBM35A-003A-XX<br />
EBM35A-003B-XX<br />
Spacing 21 mm<br />
EBM35A-023A-XX<br />
EBM35A-023B-XX<br />
Spacing 40 mm<br />
1/8” NPTF<br />
# 10-32 UNF<br />
EBM35A-004A-XX<br />
EBM35A-004B-XX<br />
EBM35A-024A-XX<br />
EBM35A-024B-XX<br />
Number of stations (03=3 stations)<br />
Other options available. Consult factory.<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
use 40 mm spacing for valves w/ gage port.<br />
** Pressure Regulators :<br />
35A-00M (Adjusting knob)<br />
35A-00L (Slotted stem)<br />
35A-00U (Locking stem)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 35<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
VALVE BLANKING<br />
PLATE<br />
B<br />
5 5<br />
5,2 DIA<br />
2 MTG. HOLES<br />
21,0 "A" 21,0<br />
21<br />
5<br />
35,5<br />
2 2<br />
1/8” 2 PORTS<br />
BOTH ENDS<br />
REGULATOR<br />
BLANKING PLATE<br />
8,0 58,3<br />
5,0<br />
32,5<br />
20,1<br />
47,5<br />
56,5<br />
28,0<br />
17,75<br />
14,0 16,0<br />
SPACING SIZE<br />
A<br />
OPTIONAL<br />
BOTTOM PORTS<br />
10,5<br />
25,5<br />
40,0<br />
91,1<br />
STANDARD<br />
FOR GAGES<br />
PORT SIZE<br />
B<br />
21.0<br />
40.0<br />
1/8”<br />
15.5<br />
# 10-32<br />
18.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 35<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v plug-in<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
35A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR "PLUG-IN" CIRCUIT BAR<br />
Universal valve<br />
CYL<br />
Valve less base<br />
IN EXH<br />
35A-B00-DXXJ-XFM<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
HOW TO ORDER "PLUG-IN" CIRCUIT BAR **<br />
ECD35A-xxxx-xx-xx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
21<br />
ECD35A-001A-A0-XX*<br />
ECD35A-002A-A0-XX*<br />
# 10-32 UNF<br />
21<br />
ECD35A-001B-A0-XX*<br />
ECD35A-002B-A0-XX*<br />
1/8” NPTF<br />
30<br />
ECD35A-031A-C0-XX*<br />
ECD35A-032A-C0-XX*<br />
# 10-32 UNF<br />
30<br />
ECD35A-031B-C0-XX*<br />
ECD35A-032B-C0-XX*<br />
Number of stations (03=3 stations)<br />
* * Other options available. Consult factory.<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector (9, 15 or 25).<br />
* A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal w/light (120V)<br />
CB = terminal w/light (240V)<br />
CD = terminal w/light (24V)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 35<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004. • Plug-in protector : 16520.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
VALVE BLANKING<br />
PLATE<br />
21,0<br />
“A” 21,0<br />
21,0<br />
22,8<br />
61,0<br />
5,1<br />
17<br />
68,5<br />
47,5<br />
2<br />
2<br />
30,0<br />
19,8<br />
17,0 20,0<br />
40<br />
13,5<br />
5,0<br />
37,0<br />
1/8” PORTS<br />
1 & 3 EACH END<br />
29,0<br />
57,3<br />
1" NPSM<br />
EACH END<br />
4,5<br />
78,0<br />
84,8<br />
2<br />
4,5<br />
5,2 DIA. (2) MOUNT-<br />
ING HOLES<br />
SPACING SIZE<br />
A<br />
37,0<br />
STANDARD<br />
FOR TERMINAL<br />
STRIPS<br />
21.0<br />
30.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 35<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v<br />
plug-in<br />
with side<br />
Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
35A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR "PLUG-IN" CIRCUIT BAR<br />
Universal valve<br />
CYL<br />
Valve less base<br />
Valve less base w/ gage port<br />
IN EXH<br />
35A-B00-DXXJ-XFM<br />
35A-F00-DXXJ-XFM<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
ECD35A-xxxx-xx-xx<br />
HOW TO ORDER "PLUG-IN" CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY)* *<br />
Port size<br />
1/8” NPTF<br />
# 10-32 UNF<br />
1/8” NPTF<br />
# 10-32 UNF<br />
1/8” NPTF<br />
# 10-32 UNF<br />
Spacing<br />
mm<br />
21<br />
21<br />
30<br />
30<br />
40<br />
40<br />
Bottom cylinder ports<br />
ECD35A-004A-A0-XX*<br />
ECD35A-004B-A0-XX*<br />
ECD35A-034A-C0-XX*<br />
ECD35A-034B-C0-XX*<br />
ECD35A-024A-A0-XX*<br />
ECD35A-024B-A0-XX*<br />
Number of stations (03=3 stations)<br />
* * Other options available. Consult factory.<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector (9, 15 or 25).<br />
minimum spacing for terminal strips is 30 mm.<br />
use 40 mm spacing for valves w/gage port.<br />
** Pressure Regulators :<br />
35A-00M (Adjusting knob)<br />
35A-00L (Slotted stem)<br />
35A-00U (Locking stem)<br />
Consult “Precautions” before use, installation or service of MAC Valves.<br />
* A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal w/light (120V)<br />
CB = terminal w/light (240V)<br />
CD = terminal w/light (24V)
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 35<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004. • Blanking plate regulator : M-35005.<br />
• Plug-in protector : 16520.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
VALVE BLANKING<br />
PLATE<br />
21,0<br />
“A” 21,0<br />
21,0<br />
22,8<br />
61,0<br />
5,1<br />
17,0<br />
68,5<br />
47,5<br />
2<br />
2<br />
30,0<br />
19,8<br />
17,0 20,0<br />
40,0<br />
13,5<br />
5,0<br />
37,0<br />
1/8” PORTS<br />
1 & 3 EACH END<br />
29,0<br />
57,3<br />
1" NPSM<br />
EACH END<br />
4,5<br />
78,0<br />
84,8<br />
5<br />
2<br />
SPACING SIZE<br />
A<br />
13,4 “B”<br />
51,0<br />
4,5<br />
37,0<br />
20,7<br />
5,2 DIA. (2)<br />
MOUNTING HOLES<br />
STANDARD<br />
FOR GAGES<br />
FOR TERMINAL<br />
STRIPS<br />
SPACING SIZE<br />
21.0<br />
40.0<br />
30.0<br />
B<br />
SLOTTED<br />
LOCKING STEM<br />
6.0<br />
ADJUSTING KNOB<br />
13.4<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 35<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v<br />
plug-in<br />
with integral<br />
terminal strip<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
35A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR "PLUG-IN" CIRCUIT BAR<br />
Universal valve<br />
CYL<br />
Valve less base<br />
IN EXH<br />
35A-B00-DXXJ-XFM<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
HOW TO ORDER "PLUG-IN" CIRCUIT BAR **<br />
ECE35A-xxxx-xx-xx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
26<br />
ECE35A-011A-C0-XX*<br />
ECE35A-012A-C0-XX*<br />
# 10-32 UNF<br />
26<br />
ECE35A-011B-C0-XX*<br />
ECE35A-012B-C0-XX*<br />
Number of stations (03=3 stations)<br />
* * Other options available. Consult factory.<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
end plate kit required: M-45017.<br />
* C0 = terminal strip<br />
CA = terminal strip w/light (120V)<br />
CB = terminal strip w/light (240V)<br />
CD = terminal strip w/light (24V)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 35<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004. • Plug-in protector : 16520.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
16.0<br />
28.5<br />
26.0<br />
LC<br />
C L<br />
C L<br />
LC<br />
30.0<br />
43.0<br />
68.5<br />
2 2 2 2<br />
1/8" - 27 N.P.T.F.<br />
1/8" - 28 B.S.P.PL.<br />
1/8" - 28 B.S.P.TR.<br />
#10-32<br />
M5 X 0.8<br />
#10-32 GAGE PORT<br />
(OPTIONAL)<br />
LC<br />
C L<br />
C L<br />
C L<br />
1/4"-18 N.P.T.F.<br />
TYP. (2) EACH END<br />
LC<br />
C L<br />
C L<br />
C L<br />
40.0<br />
5.0<br />
EX<br />
2 2<br />
IN<br />
EX<br />
IN<br />
100.4<br />
89.4<br />
58.4<br />
TYP.<br />
MODEL<br />
G<br />
33.9<br />
71.4<br />
79.7<br />
4.5<br />
TYP.<br />
158.0<br />
19.9<br />
28.9<br />
10.9<br />
1"-11 1/2 N.P.S.M.<br />
Note: Bottom & side cylinder ports not available on the same station<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 35<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v<br />
integral terminal<br />
strip <strong>and</strong> side<br />
plug-in with<br />
Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
35A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR "PLUG-IN" CIRCUIT BAR<br />
Universal valve<br />
CYL<br />
Valve less base<br />
Valve less base w/ gage port<br />
IN EXH<br />
35A-B00-DXXJ-XFM<br />
35A-F00-DXXJ-XFM<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
HOW TO ORDER "PLUG-IN" CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY) **<br />
ECE35A-xxxx-xx-xx<br />
Port size<br />
1/8” NPTF<br />
# 10-32 UNF<br />
1/8” NPTF<br />
# 10-32 UNF<br />
Spacing<br />
mm<br />
26<br />
26<br />
40<br />
40<br />
Bottom cylinder ports<br />
ECE35A-014A-C0-XX*<br />
ECE35A-014B-C0-XX*<br />
ECE35A-024A-C0-XX*<br />
ECE35A-024B-C0-XX*<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
use 40 mm spacing for valves w/ gage port.<br />
end plate kit required: M-45017.<br />
** Pressure Regulators :<br />
35A-00M (Adjusting knob)<br />
35A-00L (Slotted stem)<br />
35A-00U (Locking stem)<br />
* C0 = terminal strip<br />
CA = terminal strip w/light (120V)<br />
CB = terminal strip w/light (240V)<br />
CD = terminal strip w/light (24V)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
L O<br />
C K<br />
L O<br />
C K<br />
L O<br />
C K<br />
L O<br />
C K<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 35<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004. • Blanking plate regulator : M-35005.<br />
• Plug-in protector : 16520.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
16.0<br />
28.5<br />
LC<br />
A<br />
C L<br />
C L<br />
LC<br />
43.0<br />
68.5<br />
#10-32 GAGE PORT<br />
(OPTIONAL)<br />
B<br />
LC<br />
C L<br />
C LC<br />
C L<br />
1/4"-18 N.P.T.F.<br />
TYP. (2) EACH END<br />
1/8" - 27 N.P.T.F.<br />
1/8" - 28 B.S.P.PL.<br />
1/8" - 28 B.S.P.TR.<br />
#10-32<br />
M5 X 0.8<br />
LC<br />
C L<br />
C L<br />
C L<br />
EX<br />
2 2<br />
151.4<br />
WITH SIDE<br />
REGULATOR<br />
100.4<br />
IN<br />
IN<br />
EX<br />
89.4<br />
58.4<br />
TYP.<br />
MODEL<br />
G<br />
33.9<br />
71.4<br />
79.7<br />
4.5<br />
TYP.<br />
158.0<br />
19.9<br />
28.9<br />
10.9<br />
1"-11 1/2 N.P.S.M.<br />
Dim.<br />
B<br />
Dim.<br />
5.0<br />
40.0<br />
A<br />
SLOTTED<br />
LOCKING STEM<br />
ADJUSTABLE KNOB<br />
6.0<br />
13.4<br />
STANDARD<br />
SPACING<br />
SPACING<br />
FOR GAUGES<br />
26.0<br />
40.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Section 2 Options<br />
Consult “Precautions” before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Codification table for voltages / Wire length / Manual operators / Electrical connections<br />
VALVE CODE ➤<br />
- D XX X - X XX<br />
1 2 3 4<br />
OPTIONS AVAILABLE FOR<br />
- Solenoid valves 35 & 45 Series<br />
Consult “Precautions”before use, installation or service of MAC Valves.
OPTIONS<br />
Back<br />
1. VOLTAGE<br />
- D XX X - X XX VOLTAGE<br />
AD 24/60<br />
AE 200/60<br />
AF 240/50<br />
AG 100/50, 100/60, 110/60<br />
DB 12 VDC (5.4 W)<br />
DC 12 VDC (7.5 W)<br />
DD 24 VDC (7.3 W)<br />
DE<br />
12 VDC (12.7 W) CLSF<br />
DK 110 VDC (5.8 W)<br />
DL 64 VDC (6.0 W)<br />
DM 36 VDC (5.8 W)<br />
DN 6 VDC (6.0 W)<br />
DP 48 VDC (5.8 W)<br />
DU 24 VDC (6.0 W)<br />
EA 12 VDC (6.0 W)<br />
FA 12 VDC (1.8 W)<br />
FE 12 VDC (2.4 W)<br />
FF 24 VDC (2.4 W)<br />
2. WIRE LENGTH<br />
- D XX X - X XX WIRE LENGTH<br />
B 24”<br />
C 36”<br />
D 48”<br />
E 72”<br />
F 96”<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Back<br />
3. MANUAL OPERATOR<br />
- D XX X - X XX MANUAL OPERATOR<br />
0 No operator<br />
1 Non-locking recessed<br />
2 Locking recessed<br />
3 Non-locking extended<br />
4 Locking extended<br />
4. ELECTRICAL CONNECTION<br />
- D XX X - X XX ELECTRICAL CONNECTION<br />
BA Flying leads<br />
BK BA with protection diode<br />
BL BA with protection varistor<br />
CA 1/2" NPS conduit<br />
*FN Plug-in with diode<br />
*FP Plug-in with M.O.V.<br />
JB Rectangular connector<br />
JD Rectangular connector with light<br />
JM Rectangular connector, male only<br />
KA Square connector<br />
KB Square connector with protection diode<br />
KC Square connector with protection varistor<br />
KD Square connector with light<br />
KE Square connector with light <strong>and</strong> protection diode<br />
KF Square connector with light <strong>and</strong> protection varistor<br />
KJ Square connector (male only)<br />
KK Square connector with protection diode (male only)<br />
KL Square connector with protection varistor (male only)<br />
TA Dual tabs<br />
TB TA with protection diode<br />
TD TA with light<br />
TE TA with light <strong>and</strong> protection diode<br />
TJ Dual tabs (male only)<br />
TK TJ with protection diode<br />
TM TJ with light<br />
TN TJ with light <strong>and</strong> protection diode<br />
* For use with the ECD <strong>and</strong> ECE style circuit bars.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
PIN #6<br />
PIN #9<br />
MOD. SD09<br />
PIN #1<br />
PIN #5<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 9<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 7 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 2 common wires<br />
PIN #9<br />
PIN #15<br />
MOD. SD15<br />
PIN #1<br />
PIN #8<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 15<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 12 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 3 common wires<br />
PIN #14<br />
PIN #25<br />
MOD. SD25<br />
PIN #1<br />
PIN #13<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 25<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 20 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 5 common wires<br />
Note : Use desired MOD. number after circuit bar part number
O p t i o n s<br />
OPTIONS<br />
Connector termination details<br />
CONNECTOR<br />
SOL 1<br />
SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />
Single solenoid circuit bar<br />
SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />
CONNECTOR<br />
SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />
Double solenoid circuit bar<br />
SD09 SD15 SD25<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
8<br />
COMMON (+)<br />
13<br />
COMMON (+)<br />
21<br />
COMMON (+)<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
9<br />
COMMON (+)<br />
8<br />
SOL. 8<br />
8<br />
SOL. 8<br />
14<br />
COMMON (+)<br />
22<br />
COMMON (+)<br />
9<br />
SOL. 9<br />
9<br />
SOL. 9<br />
10 SOL. 10<br />
10 SOL. 10<br />
11<br />
SOL. 11<br />
11<br />
SOL. 11<br />
12 SOL. 12<br />
12 SOL. 12<br />
15<br />
COMMON (+)<br />
23<br />
COMMON (+)<br />
13<br />
SOL. 13<br />
14 SOL. 14<br />
15<br />
SOL. 15<br />
16 SOL. 16<br />
24<br />
COMMON (+)<br />
17<br />
18 SOL. 18<br />
19<br />
20 SOL. 20<br />
SOL. 17<br />
SOL. 19<br />
25<br />
COMMON (+)
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Circuit bar mounting<br />
non plug-in<br />
cylinder ports<br />
in valve<br />
non plug-in<br />
cylinder ports<br />
in base<br />
non plug-in<br />
cylinder ports<br />
in base with<br />
Pr. Reg.<br />
non plug-in<br />
add-on style<br />
cylinder ports<br />
in base<br />
non plug-in<br />
add-a-unit<br />
stations<br />
plug-in<br />
plug-in<br />
with Pr. Reg.<br />
add-on style<br />
plug-in<br />
add-on style<br />
plug in<br />
with Pr. Reg.<br />
plug-in<br />
add-a-unit<br />
stations<br />
plug-in<br />
add-a-unit<br />
stations<br />
with Pr. Reg.<br />
Manual operator<br />
Armature<br />
Coil<br />
Push pin<br />
Pole piece<br />
“D” seal<br />
1<br />
Poppet<br />
2<br />
3<br />
Valve return spring<br />
SERIES FEATURES<br />
• Balanced poppet equals consistent high shifting forces.<br />
• Valve shifting forces are consistent <strong>and</strong> independent of pressure fluctuations.<br />
• High solenoid <strong>and</strong> return spring forces ensure high speed <strong>and</strong> precise repeatability.<br />
• Built-in wear compensation - valve stroke is shorter than solenoid stroke.<br />
• Constant high flow maintained throughout the pressure range.<br />
• Exhaust contaminants are isolated from the solenoid.<br />
• Full flow exhaust.<br />
• Universal porting - 6 functions in one valve.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting Profile<br />
non plug-in<br />
26 mm<br />
3/2 NO-NC 1/4” - 3/8” 0.5C v cylinder ports<br />
in valve<br />
38 mm<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Valve port size<br />
Universal valve<br />
NC only valve<br />
2<br />
2<br />
1/8” NPTF<br />
1/4” NPTF<br />
1 3<br />
37A-EGO-HXXX-XXX<br />
37A-EHO-HXXX-XXX<br />
1 3<br />
37A-FGO-HXXX-XXX<br />
37A-FHO-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
A 18”<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
DA 24VDC (5.2 W)<br />
x Other Options<br />
AA 120VAC (must use with<br />
rectified connector)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />
1 Non-locking<br />
MA Plug-in wire assy<br />
MC Plug-in wire assy<br />
with light<br />
BA Flying leads<br />
BC Flying leads with light<br />
HA Plug-in connector with<br />
rectifier <strong>and</strong> light<br />
xx Other Options<br />
EBM37A-xxxxx-xx<br />
Port size<br />
COMMON INLET & EXHAUST<br />
Without regulators (20mm)<br />
With regulators (20mm)<br />
26mm Profile<br />
1/4” NPTF<br />
EBM37A-01CAK-XX<br />
-<br />
38mm Profile<br />
3/8” NPTF<br />
-<br />
EBM37A-01JAK-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
** Pressure Regulators :<br />
PR37A-GOAx<br />
X=A (0 to 120 PSI)<br />
X=B (0 to 80 PSI)<br />
X=C (0 to 30 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37002.<br />
• Regulator blanking plate : R-47003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
97.5<br />
7.0<br />
TYP.<br />
109.9<br />
29.2<br />
12<br />
12<br />
12<br />
12<br />
63.0<br />
24.5<br />
1 3<br />
10<br />
10<br />
10<br />
10<br />
21.5<br />
25.0 20.5<br />
B<br />
A<br />
Dim.<br />
26 mm<br />
38 mm<br />
“A”<br />
26.0<br />
38.0<br />
“B”<br />
75.1<br />
87.1<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
3/2 NO-NC 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
non plug-in<br />
cylinder ports<br />
in base<br />
26 mm<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
37A-C10-HXXX-XXX<br />
1 3<br />
37A-D10-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
A 18”<br />
1 Non-locking<br />
MA<br />
Plug-in wire assy<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
MC<br />
Plug-in wire assy<br />
with light<br />
DA 24VDC (5.2 W)<br />
x<br />
Other Options<br />
BA<br />
Flying leads<br />
AA<br />
120VAC (must use with<br />
BC<br />
Flying leads with light<br />
rectified connector)<br />
HA<br />
Plug-in connector with<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
EBM37A-00xxx-xx<br />
xx<br />
rectifier <strong>and</strong> light<br />
Other Options<br />
Port size<br />
Side cylinder ports (18 mm)<br />
Bottom cylinder ports (18 mm)<br />
1/8” NPTF<br />
1/4” NPTF<br />
6 mm tube receptacle<br />
EBM37A-00AAA-XX<br />
EBM37A-00AAB-XX<br />
EBM37A-00AAG-XX<br />
EBM37A-00BAA-XX<br />
EBM37A-00BAB-XX<br />
EBM37A-00BAG-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Dim.<br />
“B”<br />
1/4”<br />
16.5<br />
M6 Carstick<br />
18.5<br />
Number of 1 2 3 4 5 6 7 8 9 10<br />
stations<br />
“A” 50.0 68.0 86.0 104.0 122.0 140.0 158.0 176.0 194.0 212.0<br />
Dimensions are based on 18 mm centerline spacing<br />
75.10<br />
26.00<br />
49.00<br />
TYP.<br />
21.50<br />
TYP.<br />
3<br />
1<br />
1/4" - 18 N.P.T.F.<br />
2 HOLES<br />
BOTH ENDS<br />
1/4" - 19 B.S.P.TR<br />
2 HOLES<br />
BOTH ENDS<br />
1/4" - 19 B.P.S.PL<br />
2 HOLES<br />
BOTH ENDS<br />
35.50<br />
"B"<br />
2<br />
28.00<br />
7.00<br />
6.25 DIA.<br />
(2) MTG HOLES<br />
18.00<br />
TYP.<br />
18.00<br />
TYP.<br />
10<br />
2<br />
10<br />
"A"<br />
10<br />
10<br />
2<br />
2<br />
12<br />
12<br />
12<br />
12<br />
25.00 22.00<br />
TYP.<br />
BOTH<br />
ENDS<br />
DIM FOR 1/4" &<br />
M6 CARSTICK.<br />
7.00<br />
35.20<br />
1/4" - 18 N.P.T.F.<br />
TYP. PER STATION<br />
1/8" - 27 N.P.T.F.<br />
TYP. PER STATION<br />
1/4" - 19 B.S.P.TR<br />
TYP. PER STATION<br />
1/4" - 19 B.P.S.PL<br />
TYP. PER STATION<br />
1/8" - 28 B.S.P.TR.<br />
TYP. PER STATION<br />
1/8" - 28 B.S.P.PL.<br />
TYP. PER STATION<br />
13.00<br />
TYP.<br />
9.50<br />
TYP.<br />
3<br />
1<br />
* M6 Carstick available only on side port<br />
109.90<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
3/2 NO-NC 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
non plug-in<br />
cylinder ports<br />
in base with<br />
Pr. Reg.<br />
38 mm<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
37A-C1O-HXXX-XXX<br />
1 3<br />
37A-D1O-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
Voltage<br />
Wire length<br />
Manual operator<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
A 18”<br />
1 Non-locking<br />
MA<br />
Plug-in wire assy<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
MC<br />
Plug-in wire assy<br />
with light<br />
DA 24VDC (5.2 W)<br />
AA 120VAC (must use with<br />
x<br />
Other Options<br />
BA<br />
BC<br />
Flying leads<br />
Flying leads with light<br />
rectified connector)<br />
HA<br />
Plug-in connector with<br />
xx<br />
Other Options<br />
xx<br />
rectifier <strong>and</strong> light<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />
EBM37A-00xxx-xx<br />
Port size<br />
Side cylinder ports (18 mm)<br />
Bottom cylinder ports (18 mm)<br />
1/8” NPTF<br />
1/4” NPTF<br />
6 mm tube receptacle<br />
EBM37A-00FAA-XX<br />
EBM37A-00FAB-XX<br />
EBM37A-00FAG-XX<br />
EBM37A-00GAA-XX<br />
EBM37A-00GAB-XX<br />
EBM37A-00GAG-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
** Pressure Regulators :<br />
PR37A-GOAx<br />
X=A (0 to 120 PSI)<br />
X=B (0 to 80 PSI)<br />
X=C (0 to 30 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />
• Regulator blanking plate : R-47003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of 2 3 4 5 6 7 8 9 10 11<br />
stations<br />
“A” 63.7 81.7 99.7 117.7 135.7 153.7 171.7 189.7 207.7 225.7<br />
Dimensions are based on 18 mm centerline spacing<br />
87.6<br />
38.0<br />
1 3<br />
3/8" - 18 N.P.T.F.<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.S.P.TR<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.P.S.PL<br />
2 HOLES<br />
BOTH ENDS<br />
33.8<br />
10.0<br />
2<br />
18.0<br />
TYP.<br />
18.0<br />
TYP.<br />
2<br />
10<br />
"A"<br />
10<br />
12<br />
10<br />
12<br />
12<br />
GAGE<br />
6.25 DIA.<br />
2 MTG.<br />
HOLES<br />
2<br />
1/4" - 18 N.P.T.F.<br />
TYP. PER STATION<br />
1/8" - 27 N.P.T.F.<br />
TYP. PER STATION<br />
25.0 25.0<br />
TYP TYP BOTH<br />
BOTH ENDS<br />
ENDS<br />
2<br />
DIM. FOR 1/4" &<br />
M6 CARSTICK<br />
7.0<br />
TYP<br />
10<br />
33.8<br />
TYP<br />
12<br />
"E"<br />
1/4" - 19 B.S.P.TR<br />
TYP. PER STATION<br />
1/8" - 28 B.S.P.TR.<br />
TYP. PER STATION<br />
1/4" - 19 B.P.S.PL<br />
TYP. PER STATION<br />
1/8" - 28 B.S.P.PL.<br />
TYP. PER STATION<br />
3<br />
1<br />
Dim.<br />
“E”<br />
Regulator with locking<br />
adjusting screw<br />
135.8<br />
Regulator with<br />
adjusting screw<br />
131.8<br />
Regulator with<br />
adjusting knob<br />
139.6<br />
* M6 Carstick available only on side port<br />
Note: Bottom & side cylinder ports not available on the same station<br />
20.0<br />
TYP.<br />
21.5<br />
TYP.<br />
46.0<br />
TYP.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
3/2 NO-NC 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
non plug-in<br />
add-on style<br />
cylinder ports<br />
in base<br />
38 mm<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
37A-C1O-HXXX-XXX<br />
1 3<br />
37A-D1O-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
Voltage<br />
Wire length<br />
Manual operator<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
A 18”<br />
1 Non-locking<br />
MA<br />
Plug-in wire assy<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
MC<br />
Plug-in wire assy<br />
with light<br />
DA 24VDC (5.2 W)<br />
x<br />
Other Options<br />
BA<br />
Flying leads<br />
AA<br />
120VAC (must use with<br />
BC<br />
Flying leads with light<br />
rectified connector)<br />
HA<br />
Plug-in connector with<br />
xx<br />
Other Options<br />
xx<br />
rectifier <strong>and</strong> light<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
EBM37A-00xxx-xx<br />
Side cylinder ports (18 mm)<br />
Bottom cylinder ports (18 mm)<br />
1/8” NPTF<br />
1/4” NPTF<br />
6 mm tube receptacle<br />
EBM37A-00DBA-XX<br />
EBM37A-00DBB-XX<br />
EBM37A-00DBG-XX<br />
EBM37A-00EBA-XX<br />
EBM37A-00EBB-XX<br />
EBM37A-00EBG-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
add-a-unit stations may be added to above bars. Clic here for model numbers.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001. • End plate Kit : M-37005-0<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
12<br />
12<br />
12<br />
12<br />
1<br />
2<br />
2 2<br />
114.4<br />
63.0<br />
24.5<br />
10<br />
10<br />
10<br />
10<br />
21.5<br />
3<br />
33.8<br />
99.6<br />
7.0<br />
TYP.<br />
21.7 18.0 25.0<br />
87.6<br />
2 2 2<br />
38.0<br />
10.0<br />
25.0 18.0 21.7 26.8<br />
Note: Bottom & side cylinder ports not available on the same station<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
3/2 NO-NC 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
non plug-in<br />
add-a-unit<br />
stations<br />
38 mm<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
37A-C1O-HXXX-XXX<br />
1 3<br />
37A-D1O-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
Voltage<br />
Wire length<br />
Manual operator<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
A 18”<br />
1 Non-locking<br />
MA<br />
Plug-in wire assy<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
MC<br />
Plug-in wire assy<br />
with light<br />
DA 24VDC (5.2 W)<br />
x<br />
Other Options<br />
BA<br />
Flying leads<br />
AA<br />
120VAC (must use with<br />
BC<br />
Flying leads with light<br />
rectified connector)<br />
HA<br />
Plug-in connector with<br />
xx<br />
Other Options<br />
xx<br />
rectifier <strong>and</strong> light<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
EBM37A-00xxx-xx<br />
Side cylinder ports (18 mm)<br />
Bottom cylinder ports (18 mm)<br />
1/8” NPTF<br />
1/4” NPTF<br />
6 mm tube receptacle<br />
EBM37A-00DCA-XX<br />
EBM37A-00DCB-XX<br />
EBM37A-00DCG-XX<br />
EBM37A-00ECA-XX<br />
EBM37A-00ECB-XX<br />
EBM37A-00ECG-XX<br />
Number of stations (01, 02, 03 or 04)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />
• O-ring port seal (x2) : 17015-01. • Tie rod (x2) : 79007-01 (one station length)<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
12<br />
12<br />
12<br />
12<br />
1<br />
2<br />
2 2<br />
114.4<br />
63.0<br />
24.5<br />
10<br />
10<br />
10<br />
10<br />
21.5<br />
3<br />
33.8<br />
99.6<br />
7.0<br />
TYP.<br />
21.7 18.0 25.0<br />
87.6<br />
2 2 2<br />
38.0<br />
10.0<br />
25.0 18.0 21.7 26.8<br />
Note: Bottom & side cylinder ports not available on the same station<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
3/2 NO-NC 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
plug-in<br />
32.5 mm<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
37A-C1O-HXXP-XXX<br />
1 3<br />
37A-D1O-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
FA<br />
Plug-in<br />
DB 24VDC (2.4 W)<br />
FC<br />
Plug-in with light<br />
DA 24VDC (5.2 W)<br />
FE<br />
Plug-in with suppression diode<br />
AA<br />
120VAC (Mod. No. required see below)<br />
FG<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
xx<br />
with LED light<br />
Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR**<br />
ECD37A-xxxxx-xxxx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
18<br />
ECD37A-00AAA-A0XX<br />
ECD37A-00BAA-A0XX<br />
1/4” NPTF<br />
18<br />
ECD37A-00AAB-A0XX<br />
ECD37A-00BAB-A0XX<br />
6 mm tube receptacle<br />
18<br />
ECD37A-00AAG-A0XX<br />
ECD37A-00BAG-A0XX<br />
1/8” NPTF<br />
30<br />
ECD37A-01AAA-C0XX<br />
ECD37A-01BAA-C0XX<br />
1/4” NPTF<br />
30<br />
ECD37A-01AAB-C0XX<br />
ECD37A-01BAB-C0XX<br />
6 mm tube receptacle<br />
30<br />
ECD37A-01AAG-C0XX<br />
ECD37A-01BAG-C0XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector (9, 15 or 25).<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />
• Base wire plug-in protector : 16520.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
109.1<br />
COND.<br />
1<br />
3<br />
19.5 20.7<br />
TYP. TYP.<br />
3/8" N.P.T.F.<br />
2 HOLES<br />
BOTH ENDS<br />
28.15<br />
31.7<br />
TYP.<br />
6.0<br />
TYP.<br />
9.5<br />
22.85<br />
22.85<br />
12<br />
10<br />
12<br />
10<br />
18.0<br />
TYP.<br />
18.0<br />
TYP.<br />
A<br />
12<br />
10<br />
12<br />
10<br />
2<br />
2<br />
2<br />
2<br />
6.25 DIA.<br />
2 MTG.<br />
HOLES<br />
1/2"-14 N.P.S.M. CONDUIT<br />
68.0<br />
29.2<br />
14.6<br />
TYP.<br />
COND.<br />
1 3<br />
18.0<br />
TYP.<br />
42.1<br />
TYP.<br />
75.6<br />
TYP.<br />
32.5<br />
Number of 1 2 3 4 5 6 7 8 9 10<br />
stations<br />
“A” 45.7 63.7 81.7 99.7 117.7 135.7 153.7 171.7 189.7 207.7<br />
Dimensions are based on 18 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
3/2 NO-NC 1/8” - 1/4” 0.5C v<br />
plug-in<br />
with Pr. Reg.<br />
44 mm<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
37A-C1O-HXXP-XXX<br />
1 3<br />
37A-D1O-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
FA<br />
Plug-in<br />
DB 24VDC (2.4 W)<br />
FC<br />
Plug-in with light<br />
DA 24VDC (5.2 W)<br />
FE<br />
Plug-in with suppression diode<br />
AA<br />
120VAC (Mod. No. required see below)<br />
FG<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
xx<br />
with LED light<br />
Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />
ECD37A-xxxxx-xxxx<br />
Port size<br />
Spacing mm<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
1/4” NPTF<br />
1/8” NPTF<br />
1/4” NPTF<br />
18<br />
18<br />
30<br />
30<br />
ECD37A-00CDA-A0XX<br />
ECD37A-00CDB-A0XX<br />
ECD37A-01CDA-C0XX<br />
ECD37A-01CDB-C0XX<br />
Number of stations (03=3 stations)<br />
** Other options available, consult factory.<br />
Note :<br />
clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector (9, 15 or 25).<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
** Pressure Regulators :<br />
PR37A-GOAx<br />
X=A (0 to 120 PSI)<br />
X=B (0 to 80 PSI)<br />
X=C (0 to 30 PSI)<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />
• Base wire plug-in protector : 16520. • Regulator blanking plate : R-47003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
B<br />
D<br />
SHOWN W\ SANDWICH<br />
REGULATOR<br />
COND.<br />
116.1<br />
1"- 11 1/2 N.P.S.M.<br />
CONDUIT<br />
1<br />
3<br />
3/8" N.P.T.F.<br />
3 HOLES<br />
BOTH ENDS<br />
SHOWN W\ STANDARD<br />
REGULATOR<br />
40.7<br />
20.35<br />
COND. 1<br />
3<br />
44.0<br />
19.2 23.2<br />
TYP. TYP.<br />
33.0<br />
TYP. 6.0<br />
TYP.<br />
9.5<br />
18.5<br />
TYP.<br />
48.6<br />
TYP.<br />
87.1<br />
TYP.<br />
33.55<br />
A<br />
22.85<br />
12<br />
12<br />
10<br />
10<br />
2<br />
18.0<br />
TYP.<br />
18.0<br />
TYP.<br />
2<br />
C<br />
12<br />
10<br />
12<br />
10<br />
Dim.<br />
“A”<br />
Dim.<br />
“B”<br />
“D”<br />
1/4”<br />
25.85<br />
1/8”<br />
25.85<br />
Regulator with locking<br />
adjusting screw<br />
188.8<br />
182.5<br />
6 mm Legris<br />
22.85<br />
Regulator with<br />
adjusting screw<br />
184.7<br />
178.4<br />
6.25 DIA.<br />
2 MTG.<br />
HOLES<br />
Number of 1 2 3 4 5 6 7 8 9 10<br />
stations<br />
Regulator with<br />
“C” 45.7 63.7 81.7 99.7 117.7 135.7 153.7 171.7 189.7 207.7<br />
adjusting knob<br />
191.7<br />
Dimensions are based on 18 mm centerline spacing<br />
185.4<br />
Note: Bottom & side cylinder ports not available on the same station<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
3/2 NO-NC 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
add-on style<br />
plug-in<br />
44 mm<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
37A-C1O-HXXP-XXX<br />
1 3<br />
37A-D1O-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
FA<br />
Plug-in<br />
DB 24VDC (2.4 W)<br />
FC<br />
Plug-in with light<br />
DA 24VDC (5.2 W)<br />
FE<br />
Plug-in with suppression diode<br />
AA<br />
120VAC (Mod. No. required see below)<br />
FG<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
xx<br />
with LED light<br />
Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR**<br />
ECD37A-xxxxx-xxxx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
18<br />
ECD37A-00AEA-A0XX<br />
ECD37A-00BEA-A0XX<br />
1/4” NPTF<br />
18<br />
ECD37A-00AEB-A0XX<br />
ECD37A-00BEB-A0XX<br />
6 mm tube receptacle<br />
18<br />
ECD37A-00AEG-A0XX<br />
ECD37A-00BEG-A0XX<br />
1/8” NPTF<br />
30<br />
ECD37A-01AEA-C0XX<br />
ECD37A-01BEA-C0XX<br />
1/4” NPTF<br />
30<br />
ECD37A-01AEB-C0XX<br />
ECD37A-01BEB-C0XX<br />
6 mm tube receptacle<br />
30<br />
ECD37A-01AEG-C0XX<br />
ECD37A-01BEG-C0XX<br />
Number of stations (03=3 stations)<br />
** Other options available, consult factory.<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
clic for multi-pin connector (9, 15 or 25).<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
add-a-unit stations may be added to above bars. Clic here for model numbers.<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001. • End plate kit : M-37003-01<br />
• Base wire plug-in protector : 16520. • Isolator disc between add-a-units : 28438.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
“C” w/regulator<br />
1<br />
-<br />
2<br />
53.6<br />
3<br />
71.6<br />
4<br />
89.6<br />
5<br />
6<br />
7<br />
107.6 125.6 143.6 161.6 179.6 197.6<br />
8<br />
9<br />
10<br />
117.3<br />
1"-11 1/2 N.P.S.M. CONDUIT<br />
“C” w/o regulator<br />
-<br />
51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />
“D” 21.7 39.7 57.7 75.7 - - - - -<br />
Dimensions are based on 18 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
-<br />
3<br />
1<br />
COND.<br />
79.2<br />
3/8" N.PT.F.<br />
TYP.(2) BOTH ENDS<br />
2<br />
10.85<br />
TYP.<br />
10.85<br />
TYP.<br />
2<br />
10<br />
12<br />
16.0<br />
D<br />
10<br />
2<br />
12<br />
2<br />
B<br />
A<br />
2<br />
10<br />
12<br />
C<br />
33.55<br />
TYP.<br />
9.5<br />
TYP.<br />
6.0<br />
TYP.<br />
33.0<br />
TYP.<br />
6.25 DIA. HOLE<br />
TYP.(2)<br />
44.0<br />
23.2<br />
TYP.<br />
19.2<br />
TYP.<br />
3<br />
1<br />
COND.<br />
40.7<br />
20.35<br />
TYP.<br />
18.5<br />
TYP.<br />
48.6<br />
TYP.<br />
Dim.<br />
“A”<br />
1/8”<br />
22.65<br />
1/4”<br />
24.20<br />
6 mm Legris<br />
22.85<br />
1/8” w/regulator<br />
-<br />
1/4” w/regulator<br />
-<br />
87.1<br />
TYP.<br />
“B”<br />
22.85<br />
22.85<br />
25.85<br />
21.20<br />
22.60<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
3/2 NO-NC 1/8” - 1/4” 0.5C v<br />
add-on style<br />
plug in<br />
with Pr. Reg.<br />
44 mm<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
37A-C1O-HXXP-XXX<br />
1 3<br />
37A-D1O-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
FA<br />
Plug-in<br />
DB 24VDC (2.4 W)<br />
FC<br />
Plug-in with light<br />
DA 24VDC (5.2 W)<br />
FE<br />
Plug-in with suppression diode<br />
AA<br />
120VAC (Mod. No. required see below)<br />
FG<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
xx<br />
with LED light<br />
Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />
ECD37A-xxxxx-xxxx<br />
Port size<br />
Spacing mm<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
1/4” NPTF<br />
1/8” NPTF<br />
1/4” NPTF<br />
18<br />
18<br />
30<br />
30<br />
ECD37A-00CEA-A0XX<br />
ECD37A-00CEB-A0XX<br />
ECD37A-01CEA-C0XX<br />
ECD37A-01CEB-C0XX<br />
Number of stations (03=3 stations)<br />
** Pressure Regulators :<br />
** Other options available, consult factory.<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number. PR37A-GOAx<br />
clic for multi-pin connector (9, 15 or 25).<br />
X=A (0 to 120 PSI)<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
X=B (0 to 80 PSI)<br />
add-a-unit stations may be added to above bars. Clic here for model numbers. X=C (0 to 30 PSI)<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001. • End plate kit : M-37003-01<br />
• Base wire plug-in protector : 16520. • Isolator disc between add-a-units : 28438.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
“C” w/regulator<br />
1<br />
-<br />
2<br />
53.6<br />
3<br />
71.6<br />
4<br />
89.6<br />
5<br />
6<br />
7<br />
107.6 125.6 143.6 161.6 179.6 197.6<br />
8<br />
9<br />
10<br />
E<br />
SHOWN W/STANDARD<br />
REGULATOR<br />
117.3<br />
1"-11 1/2 N.P.S.M. CONDUIT<br />
“C” w/o regulator<br />
“D”<br />
-<br />
21.7<br />
51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />
39.7 57.7 75.7 - - - - - -<br />
3<br />
1<br />
COND.<br />
Dimensions are based on 18 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
79.2<br />
3/8" N.PT.F.<br />
TYP.(2) BOTH ENDS<br />
2<br />
10.85<br />
TYP.<br />
10.85<br />
TYP.<br />
2<br />
10<br />
12<br />
16.0<br />
D<br />
10<br />
2<br />
12<br />
2<br />
B<br />
A<br />
2<br />
10<br />
12<br />
C<br />
33.55<br />
TYP.<br />
9.5<br />
TYP.<br />
6.0<br />
TYP.<br />
33.0<br />
TYP.<br />
6.25 DIA. HOLE<br />
TYP.(2)<br />
F<br />
SHOWN W/SANDWICH<br />
REGULATOR<br />
Dim.<br />
“A”<br />
“B”<br />
1/8”<br />
22.65<br />
22.85<br />
1/4”<br />
24.20<br />
22.85<br />
6 mm Legris<br />
22.85<br />
25.85<br />
1/8” w/regulator<br />
-<br />
21.20<br />
1/4” w/regulator<br />
-<br />
22.60<br />
103.0<br />
44.0<br />
23.2<br />
TYP.<br />
19.2<br />
TYP.<br />
3<br />
1<br />
COND.<br />
40.7<br />
20.35<br />
TYP.<br />
Dim.<br />
“E”<br />
“F”<br />
Regulator with locking<br />
adjusting screw<br />
188.8<br />
182.5<br />
Regulator with<br />
adjusting screw<br />
184.7<br />
178.4<br />
Regulator with<br />
adjusting knob<br />
191.7<br />
185.4<br />
18.5<br />
TYP.<br />
48.6<br />
TYP.<br />
87.1<br />
TYP.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
3/2 NO-NC 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
plug-in<br />
add-a-unit<br />
stations<br />
44 mm<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
37A-C1O-HXXP-XXX<br />
1 3<br />
37A-D1O-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
FA<br />
Plug-in<br />
DB 24VDC (2.4 W)<br />
FC<br />
Plug-in with light<br />
DA 24VDC (5.2 W)<br />
FE<br />
Plug-in with suppression diode<br />
AA<br />
120VAC (Mod. No. required see below)<br />
FG<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
xx<br />
with LED light<br />
Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR**<br />
ECD37A-xxxxx-xxxx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
18<br />
ECD37A-00AFA-A0XX<br />
ECD37A-00BFA-A0XX<br />
1/4” NPTF<br />
18<br />
ECD37A-00AFB-A0XX<br />
ECD37A-00BFB-A0XX<br />
6 mm tube receptacle<br />
18<br />
ECD37A-00AFG-A0XX<br />
ECD37A-00BFG-A0XX<br />
1/8” NPTF<br />
30<br />
ECD37A-01AFA-C0XX<br />
ECD37A-01BFA-C0XX<br />
1/4” NPTF<br />
30<br />
ECD37A-01AFB-C0XX<br />
ECD37A-01BFB-C0XX<br />
6 mm tube receptacle<br />
30<br />
ECD37A-01AFG-C0XX<br />
ECD37A-01BFG-C0XX<br />
Number of stations (03=3 stations) - maximum length is 4 stations.<br />
** Other options available, consult factory.<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
when add-a-unit stations are added to bars with a multi-pin connector, mod SD03 should<br />
be included with add-a-unit model number.<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />
• O-ring port seal (x2) : 17015-01 • Tie rod (x2) : 79007-01 (one station length).<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
“C” w/regulator<br />
1<br />
-<br />
2<br />
53.6<br />
3<br />
71.6<br />
4<br />
89.6<br />
5 6 7 8 9 10<br />
107.6 125.6 143.6 161.6 179.6 197.6<br />
117.3<br />
1"-11 1/2 N.P.S.M. CONDUIT<br />
“C” w/o regulator<br />
“D”<br />
-<br />
21.7<br />
51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />
39.7 57.7 75.7 - - - - - -<br />
3<br />
1<br />
COND.<br />
Dimensions are based on 18 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
79.2<br />
3/8" N.PT.F.<br />
TYP.(2) BOTH ENDS<br />
2<br />
10.85<br />
TYP.<br />
10.85<br />
TYP.<br />
2<br />
10<br />
12<br />
16.0<br />
D<br />
10<br />
2<br />
12<br />
2<br />
B<br />
A<br />
2<br />
10<br />
12<br />
C<br />
33.55<br />
TYP.<br />
9.5<br />
TYP.<br />
6.0<br />
TYP.<br />
33.0<br />
TYP.<br />
6.25 DIA. HOLE<br />
TYP.(2)<br />
44.0<br />
23.2<br />
TYP.<br />
19.2<br />
TYP.<br />
3<br />
1<br />
COND.<br />
40.7<br />
20.35<br />
TYP.<br />
18.5<br />
TYP.<br />
48.6<br />
TYP.<br />
Dim.<br />
“A”<br />
1/8”<br />
22.65<br />
1/4”<br />
24.20<br />
6 mm Legris<br />
22.85<br />
1/8” w/regulator<br />
-<br />
1/4” w/regulator<br />
-<br />
87.1<br />
TYP.<br />
“B”<br />
22.85<br />
22.85<br />
25.85<br />
21.20<br />
22.60<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 37<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
3/2 NO-NC 1/8” - 1/4” 0.5C v<br />
add-a-unit<br />
stations<br />
plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
44 mm<br />
Reset<br />
HOW TO ORDER<br />
37A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Universal valve<br />
2<br />
NC only valve<br />
2<br />
Valve less base<br />
1 3<br />
37A-C1O-HXXP-XXX<br />
1 3<br />
37A-D1O-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
FA<br />
Plug-in<br />
DB 24VDC (2.4 W)<br />
FC<br />
Plug-in with light<br />
DA 24VDC (5.2 W)<br />
FE<br />
Plug-in with suppression diode<br />
AA<br />
120VAC (Mod. No. required see below)<br />
FG<br />
Plug-in with suppression diode<br />
xx<br />
Other Options<br />
xx<br />
with LED light<br />
Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />
ECD37A-xxxxx-xxxx<br />
Port size<br />
Spacing mm<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
1/4” NPTF<br />
1/8” NPTF<br />
1/4” NPTF<br />
18<br />
18<br />
30<br />
30<br />
ECD37A-00CFA-A0XX<br />
ECD37A-00CFB-A0XX<br />
ECD37A-01CFA-C0XX<br />
ECD37A-01CFB-C0XX<br />
Number of stations (03=3 stations) - maximum length is 4 stations.<br />
** Other options available, consult factory.<br />
Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
when add-a-unit stations are added to bars with a multi-pin connector, mod<br />
SD03 should be included with add-a-unit model number.<br />
** Pressure Regulators :<br />
PR37A-GOAx<br />
X=A (0 to 120 PSI)<br />
X=B (0 to 80 PSI)<br />
X=C (0 to 30 PSI)<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 37<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 17.0 ms<br />
De-energize : 6.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />
• O-ring port seal (x2) : 17015-01 • Tie rod (x2) : 79007-01 (one station length). • Regulator blanking plate : R-47003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
“C” w/regulator<br />
1<br />
-<br />
2<br />
53.6<br />
3<br />
71.6<br />
4<br />
89.6<br />
5<br />
6<br />
7<br />
107.6 125.6 143.6 161.6 179.6 197.6<br />
8<br />
9<br />
10<br />
E<br />
SHOWN W/STANDARD<br />
REGULATOR<br />
117.3<br />
1"-11 1/2 N.P.S.M. CONDUIT<br />
“C” w/o regulator<br />
“D”<br />
-<br />
21.7<br />
51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />
39.7 57.7 75.7 - - - - - -<br />
3<br />
1<br />
COND.<br />
Dimensions are based on 18 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
79.2<br />
3/8" N.PT.F.<br />
TYP.(2) BOTH ENDS<br />
2<br />
10.85<br />
TYP.<br />
10.85<br />
TYP.<br />
2<br />
10<br />
12<br />
16.0<br />
D<br />
10<br />
2<br />
12<br />
2<br />
B<br />
A<br />
2<br />
10<br />
12<br />
C<br />
33.55<br />
TYP.<br />
9.5<br />
TYP.<br />
6.0<br />
TYP.<br />
33.0<br />
TYP.<br />
6.25 DIA. HOLE<br />
TYP.(2)<br />
F<br />
SHOWN W/SANDWICH<br />
REGULATOR<br />
Dim.<br />
“A”<br />
“B”<br />
1/8”<br />
22.65<br />
22.85<br />
1/4”<br />
24.20<br />
22.85<br />
6 mm Legris<br />
22.85<br />
25.85<br />
1/8” w/regulator<br />
-<br />
21.20<br />
1/4” w/regulator<br />
-<br />
22.60<br />
103.0<br />
44.0<br />
23.2<br />
TYP.<br />
19.2<br />
TYP.<br />
3<br />
1<br />
COND.<br />
40.7<br />
20.35<br />
TYP.<br />
Dim.<br />
“E”<br />
“F”<br />
Regulator with locking<br />
adjusting screw<br />
188.8<br />
182.5<br />
Regulator with<br />
adjusting screw<br />
184.7<br />
178.4<br />
Regulator with<br />
adjusting knob<br />
191.7<br />
185.4<br />
18.5<br />
TYP.<br />
48.6<br />
TYP.<br />
87.1<br />
TYP.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Section 2 Options<br />
Consult “Precautions” before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Codification table for voltages / Wire length / Manual operators / Electrical connections<br />
VALVE CODE ➤<br />
- H XX X - X XX<br />
1 2 3 4<br />
OPTIONS AVAILABLE FOR<br />
- Solenoid valves 37 & 47 Series<br />
Consult “Precautions”before use, installation or service of MAC Valves.
OPTIONS<br />
Back<br />
1. VOLTAGE<br />
- H XX X - X XX VOLTAGE<br />
DC Options<br />
DA 24 VDC (5.2 W)<br />
DB 24 VDC (2.4 W)<br />
DC 24 VDC (1.8 W)<br />
DD 24 VDC (1.0 W)<br />
DF 12 VDC (5.2 W)<br />
DG 12 VDC (2.4 W)<br />
DH 12 VDC (1.8 W)<br />
DJ 12 VDC (1.0 W)<br />
DL 120 VDC (6.3 W)<br />
AC Options (50/60hz)<br />
AA 120 VAC (6.7 W)<br />
AB 220 VAC (5.6 W)<br />
AC 240 VAC (5.8 W)<br />
AD 24 VAC (7.8 W)<br />
Note : AC Voltages only available with “H” & “F” type connectors. MOD FWR2 must be used with the “F” type connectors.<br />
2. WIRE LENGTH<br />
- H XX X - X XX WIRE LENGTH<br />
O<br />
No lead wire<br />
A 18”<br />
B 24”<br />
C 36”<br />
D 48”<br />
E 72”<br />
F 96”<br />
G 120”<br />
H 144”<br />
P<br />
Plug-in (used only with “F”type connector Opts.)<br />
Use “O” with MJ & MM Opts.<br />
3. MANUAL OPERATOR<br />
- H XX X - X XX MANUAL OPERATOR<br />
0 No operator<br />
1 Non-locking recessed<br />
2 Locking recessed<br />
3 Non-locking extended<br />
4 Locking extended<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Back<br />
4. ELECTRICAL CONNECTION<br />
- H XX X - X XX ELECTRICAL CONNECTION<br />
BA Flying leads<br />
BB Flying leads with ground wire<br />
BC Flying leads with led light<br />
BD Flying leads with led light & ground wire<br />
BE Flying leads with suppression diode<br />
BF Flying leads with suppression diode & ground wire<br />
BG Flying leads with suppression diode plus led light<br />
BH Flying leads with suppression diode plus led light & ground wire<br />
*BN Flying leads with suppression diode plus blocking diode<br />
*BP Flying leads with suppression diode plus blocking diode & ground wire<br />
*BR Flying leads with suppression diode plus blocking diode & led light<br />
*BS Flying leads with suppression diode plus blocking diode & led light & ground wire<br />
FA<br />
FB<br />
FC<br />
FD<br />
FE<br />
FF<br />
FG<br />
FH<br />
Plug-in<br />
Plug-in with ground wire<br />
Plug-in with led light<br />
Plug-in with led light & ground wire<br />
Plug-in with suppression diode<br />
Plug-in with suppression diode & ground wire<br />
Plug-in with suppression diode plus led light<br />
Plug-in with suppression diode plus led light & ground wire<br />
Note : FA ---- FH options for use with ECD type circuit bars<br />
HA<br />
HB<br />
HC<br />
HD<br />
HL<br />
HN<br />
Circuit board plug-in with full wave rectifier & led light<br />
Circuit board with full wave rectifier & led with ground wire<br />
Same as “HA” without lead wires<br />
Same as “HB” without lead wires<br />
Circuit board plug-in with suppression diode plus blocking diode & led light<br />
Same as “HL” without lead wires<br />
MA Plug-in wire assembly<br />
MB Plug-in wire assembly with ground wire<br />
MC Plug-in wire assembly with led light<br />
MD Plug-in wire assembly led light & ground wire<br />
ME Plug-in wire assembly with suppression diode<br />
MF Plug-in wire assembly with suppression diode & ground wire<br />
*MG Plug-in wire assembly suppression diode plus led light<br />
*MH Plug-in wire assembly suppression diode plus led light & ground wire<br />
*MN Plug-in wire assembly with suppression diode plus blocking diode<br />
*MP Plug-in wire assembly with suppression diode plus blocking diode & ground wire<br />
MR Plug-in wire assembly with suppression diode plus blocking diode & led light<br />
MS Plug-in wire assembly with suppression diode plus blocking diode & led light & ground wire<br />
MJ Plug-in housing w/o wire assembly (“MA” option without wire assembly)<br />
MM Plug-in housing w/o wire assembly (“MB” option without wire assembly)<br />
* Blocking diode is in lead wire.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
PIN #6<br />
PIN #9<br />
MOD. SD09<br />
PIN #1<br />
PIN #5<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 9<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 7 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 2 common wires<br />
PIN #9<br />
PIN #15<br />
MOD. SD15<br />
PIN #1<br />
PIN #8<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 15<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 12 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 3 common wires<br />
PIN #14<br />
PIN #25<br />
MOD. SD25<br />
PIN #1<br />
PIN #13<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 25<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 20 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 5 common wires<br />
Note : Use desired MOD. number after circuit bar part number
O p t i o n s<br />
OPTIONS<br />
Connector termination details<br />
CONNECTOR<br />
SOL 1<br />
SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />
Single solenoid circuit bar<br />
SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />
CONNECTOR<br />
SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />
Double solenoid circuit bar<br />
SD09 SD15 SD25<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
8<br />
COMMON (+)<br />
13<br />
COMMON (+)<br />
21<br />
COMMON (+)<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
9<br />
COMMON (+)<br />
8<br />
SOL. 8<br />
8<br />
SOL. 8<br />
14<br />
COMMON (+)<br />
22<br />
COMMON (+)<br />
9<br />
SOL. 9<br />
9<br />
SOL. 9<br />
10 SOL. 10<br />
10 SOL. 10<br />
11<br />
SOL. 11<br />
11<br />
SOL. 11<br />
12 SOL. 12<br />
12 SOL. 12<br />
15<br />
COMMON (+)<br />
23<br />
COMMON (+)<br />
13<br />
SOL. 13<br />
14 SOL. 14<br />
15<br />
SOL. 15<br />
16 SOL. 16<br />
24<br />
COMMON (+)<br />
17<br />
18 SOL. 18<br />
19<br />
20 SOL. 20<br />
SOL. 17<br />
SOL. 19<br />
25<br />
COMMON (+)
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 52<br />
Circuit bar mounting<br />
cylinder ports<br />
in valve<br />
add-on style<br />
cylinder ports<br />
in valve<br />
cylinder ports<br />
in base<br />
add-on style<br />
cylinder ports<br />
in base<br />
add-a-unit<br />
stations for<br />
CBM052A bar<br />
add-a-unit<br />
stations for<br />
CBP052A bar<br />
Manual operator<br />
Solenoid<br />
4-way pilot with balanced poppet<br />
Bonded spool<br />
2<br />
Air return<br />
3<br />
1<br />
SERIES FEATURES<br />
• Patented MACSOLENOID ® for fastest possible response times<br />
<strong>and</strong> virtually burn-out proof AC solenoid operation.<br />
• Optional low watt DC solenoids.<br />
• Various manual operators.<br />
• Optional memory spring.<br />
• Normally closed or normally open valve function.<br />
• May be plugged for 2-way operation.<br />
• Internal or external pilot.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 52<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC 1/8” - 1/4” 1.2C v<br />
cylinder ports<br />
in valve<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
52A-xx-xxx-DM-Dxxx-xxx<br />
SOLENOID OPERATOR<br />
Port size<br />
Pilot air<br />
Single operator<br />
NO valve<br />
NC valve<br />
Double operator<br />
NO valve<br />
NC valve<br />
10<br />
2<br />
12<br />
10<br />
2<br />
12<br />
10<br />
2<br />
12<br />
10<br />
2<br />
12<br />
1/8” NPTF<br />
Internal<br />
3 1<br />
52A-31-COA-DM-DXXX-XXX<br />
52A-31-AOA-DM-DXXX-XXX<br />
3 1<br />
52A-11-AOA-DM-DXXX-XXX<br />
3 1<br />
52A-41-AOA-DM-DXXX-XXX<br />
3 1<br />
52A-21-AOA-DM-DXXX-XXX<br />
1/4” NPTF<br />
52A-31-BOA-DM-DXXX-XXX<br />
52A-11-BOA-DM-DXXX-XXX<br />
52A-41-BOA-DM-DXXX-XXX<br />
52A-21-BOA-DM-DXXX-XXX<br />
1/8” NPTF<br />
External<br />
52A-31-AOC-DM-DXXX-XXX<br />
52A-11-AOC-DM-DXXX-XXX<br />
52A-41-AOC-DM-DXXX-XXX<br />
52A-21-AOC-DM-DXXX-XXX<br />
1/4” NPTF<br />
52A-31-BOC-DM-DXXX-XXX<br />
52A-11-BOC-DM-DXXX-XXX<br />
52A-41-BOC-DM-DXXX-XXX<br />
52A-21-BOC-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X - X XX *<br />
XX Voltage<br />
X Wire length<br />
X<br />
Manual operator<br />
XX<br />
Electrical connection<br />
JA 120/60, 110/50<br />
A<br />
18” (Flying leads)<br />
1 Non-locking<br />
KA<br />
Square connector<br />
JB 240/60, 220/50<br />
J<br />
Connector<br />
2 Locking<br />
KD<br />
Square connector<br />
with light<br />
JC 24/60, 24/50<br />
x<br />
Other Options<br />
x<br />
Other Options<br />
JB<br />
Rectangular connector<br />
DA 24VDC (5.4 W)<br />
JD<br />
Rectangular connector<br />
with light<br />
FB 24VDC (1.8 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
CBM052A-xxxxx-xx<br />
BA<br />
xx<br />
Flying leads<br />
Other Options<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard<br />
19,5 mm<br />
Spacing 26 mm<br />
(Rectangular connector)<br />
3/8” NPTF<br />
Internal<br />
CBM052A-00AAA-XX<br />
CBM052A-02AAA-XX<br />
External<br />
CBM052A-00CAA-XX<br />
CBM052A-02CAA-XX<br />
Number of stations (03=3 stations)<br />
* * Other options available. Consult factory.<br />
3<br />
O P T I O N S<br />
52A-31-AOA-DM-DXXX-XXX<br />
clic for memory spring (replace by 4).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 52<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum to 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
7.3 mm<br />
1.2C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04001. • Seal (x3) : 17015-01. • Mounting screw (x2) : 35043.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
6,5 DIA.<br />
2 HOLES<br />
32,0<br />
25,0<br />
3<br />
1<br />
2<br />
10<br />
12<br />
89,0<br />
19,5<br />
10<br />
2<br />
2<br />
2<br />
12<br />
102,3<br />
2<br />
10<br />
12<br />
2<br />
40,0<br />
26,5<br />
3<br />
1<br />
7,0<br />
38,2<br />
102,5<br />
1/8” OPTIONAL COMMON<br />
EXTERNAL PILOT.<br />
14,5<br />
51,5<br />
69,5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 52<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC 1/8” - 1/4” 1.2C v<br />
add-on style<br />
cylinder ports<br />
in valve<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
52A-xx-xxx-DM-Dxxx-xxx<br />
SOLENOID OPERATOR<br />
Port size<br />
Pilot air<br />
Single operator<br />
NO valve<br />
NC valve<br />
Double operator<br />
NO valve<br />
NC valve<br />
10<br />
2<br />
12<br />
10<br />
2<br />
12<br />
10<br />
2<br />
12<br />
10<br />
2<br />
12<br />
1/8” NPTF<br />
Internal<br />
3 1<br />
52A-31-COA-DM-DXXX-XXX<br />
52A-31-AOA-DM-DXXX-XXX<br />
3 1<br />
52A-11-AOA-DM-DXXX-XXX<br />
3 1<br />
52A-41-AOA-DM-DXXX-XXX<br />
3 1<br />
52A-21-AOA-DM-DXXX-XXX<br />
1/4” NPTF<br />
52A-31-BOA-DM-DXXX-XXX<br />
52A-11-BOA-DM-DXXX-XXX<br />
52A-41-BOA-DM-DXXX-XXX<br />
52A-21-BOA-DM-DXXX-XXX<br />
1/8” NPTF<br />
External<br />
52A-31-AOC-DM-DXXX-XXX<br />
52A-11-AOC-DM-DXXX-XXX<br />
52A-41-AOC-DM-DXXX-XXX<br />
52A-21-AOC-DM-DXXX-XXX<br />
1/4” NPTF<br />
52A-31-BOC-DM-DXXX-XXX<br />
52A-11-BOC-DM-DXXX-XXX<br />
52A-41-BOC-DM-DXXX-XXX<br />
52A-21-BOC-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X - X XX *<br />
XX Voltage<br />
X Wire length<br />
X<br />
Manual operator<br />
XX<br />
Electrical connection<br />
JA 120/60, 110/50<br />
A<br />
18” (Flying leads)<br />
1 Non-locking<br />
KA<br />
Square connector<br />
JB 240/60, 220/50<br />
J<br />
Connector<br />
2 Locking<br />
KD<br />
Square connector<br />
with light<br />
JC 24/60, 24/50<br />
x<br />
Other Options<br />
x<br />
Other Options<br />
JB<br />
Rectangular connector<br />
DA 24VDC (5.4 W)<br />
JD<br />
Rectangular connector<br />
with light<br />
FB 24VDC (1.8 W)<br />
BA<br />
Flying leads<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
CBM052A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard<br />
19,5 mm<br />
Spacing 26 mm<br />
(Rectangular connector)<br />
3/8” NPTF<br />
Internal<br />
CBM052A-00ABA-XX<br />
CBM052A-02ABA-XX<br />
External<br />
CBM052A-00CBA-XX<br />
CBM052A-02CBA-XX<br />
Number of stations (03=3 stations)<br />
* * Other options available. Consult factory.<br />
O P T I O N S<br />
Note : add-a-unit stations may be added to above bars. Clic here for model numbers.<br />
52A-31-AOA-DM-DXXX-XXX<br />
clic for memory spring (replace by 4).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 52<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum to 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
7.3 mm<br />
1.2C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04001. • Seal (x3) : 17015-01. • Mounting screw (x2) : 35043. • End plate kit (Internal) : M-52001-01.<br />
• End plate kit (External) : M-52002-01.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
CL CL CL CL<br />
40.0<br />
102.3<br />
XX<br />
CL CL CL CL<br />
1/8" OR 1/4"<br />
PORTS AVAILABLE<br />
ON THE BOTTOM OR SIDE<br />
23.2<br />
21.0<br />
10.0<br />
96.0<br />
35.0<br />
1 3<br />
12 12<br />
10<br />
10<br />
12<br />
10<br />
12<br />
10<br />
1<br />
3<br />
MODEL<br />
69.5<br />
52.5<br />
29.0<br />
14.5<br />
6.5 DIA.<br />
2 MTG.<br />
HOLES<br />
1 3<br />
38.2<br />
25.0<br />
YY<br />
21.0<br />
10.8<br />
16.0<br />
3/8" N.P.T.F.<br />
2 PLACES<br />
BOTH ENDS<br />
1/8" OPTIONAL<br />
COMMON EXTERNAL<br />
PILOT<br />
CL CL CL CL<br />
7.0<br />
TYP.<br />
YY<br />
19.5<br />
26<br />
XX<br />
113<br />
119.5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 52<br />
Function Port size Flow (Max) Individual mounting<br />
3/2 NO-NC 1/8” - 1/4” 1.2C v<br />
cylinder ports<br />
in base<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
52A-xx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Pilot air<br />
Single operator<br />
Double operator<br />
NO valve<br />
2<br />
10<br />
12<br />
NC valve<br />
2<br />
10<br />
12<br />
10<br />
NO valve<br />
2<br />
12<br />
10<br />
NC valve<br />
2<br />
12<br />
Internal<br />
3 1<br />
52A-33-OOA-DM-DXXX-XXX<br />
3 1<br />
52A-13-OOA-DM-DXXX-XXX<br />
3 1<br />
52A-43-OOA-DM-DXXX-XXX<br />
3 1<br />
52A-23-OOA-DM-DXXX-XXX<br />
External<br />
52A-33-OOC-DM-DXXX-XXX<br />
52A-13-OOC-DM-DXXX-XXX<br />
52A-43-OOC-DM-DXXX-XXX<br />
52A-23-OOC-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X - X XX *<br />
Voltage<br />
Wire length<br />
Manual operator<br />
XX X X XX<br />
JA 120/60, 110/50<br />
JB 240/60, 220/50<br />
JC 24/60, 24/50<br />
DA 24VDC (5.4 W)<br />
FB 24VDC (1.8 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
A 18” (Flying leads)<br />
1 Non-locking<br />
KA<br />
J Connector<br />
2 Locking<br />
KD<br />
x Other Options<br />
x Other Options<br />
JB<br />
JD<br />
BA<br />
xx<br />
CBP052A-xxxxx-xx<br />
Electrical connection<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
Port size (NPTF)<br />
Pilot air<br />
Spacing st<strong>and</strong>ard<br />
19,5 mm<br />
Spacing 26 mm<br />
(Rectangular connector)<br />
1/8” SIDE PORT<br />
Internal<br />
CBP052A-00AAA-XX<br />
CBP052A-02AAA-XX<br />
1/4” SIDE PORT<br />
CBP052A-00AAD-XX<br />
CBP052A-02AAD-XX<br />
1/8” SIDE PORT<br />
External<br />
CBP052A-00EAA-XX<br />
CBP052A-02EAA-XX<br />
1/4” SIDE PORT<br />
CBP052A-00EAD-XX<br />
CBP052A-02EAD-XX<br />
1/8” BOTTOM PORT<br />
Internal<br />
CBP052A-00BAA-XX<br />
CBP052A-02BAA-XX<br />
1/4” BOTTOM PORT<br />
CBP052A-00BAD-XX<br />
CBP052A-02BAD-XX<br />
1/8” BOTTOM PORT<br />
External<br />
CBP052A-00FAA-XX<br />
CBP052A-02FAA-XX<br />
1/4” BOTTOM PORT<br />
CBP052A-00FAD-XX<br />
CBP052A-02FAD-XX<br />
Number of stations (03=3 stations) ** Other options available. Consult factory.<br />
O P T I O N S<br />
52A-33-OOA-DM-DXXX-XXX<br />
clic for memory spring (replace by 6).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 52<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum to 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
7.3 mm<br />
1.2C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-52003. • Seal (x3) : 17013-01. • Mounting screw (x2) : 35043.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
25,0<br />
3<br />
1<br />
2<br />
10<br />
12<br />
90,5<br />
19,5<br />
2<br />
2<br />
10<br />
12<br />
2<br />
2<br />
10,5<br />
10<br />
2<br />
12<br />
16,0<br />
3<br />
1<br />
7,0<br />
36,0<br />
96,0<br />
32,0<br />
102,3<br />
23,2<br />
21,0<br />
10,0<br />
10,0<br />
14,5<br />
29,0<br />
51,5<br />
3/8"<br />
OPTIONAL 1/8" COMMON<br />
EXTERNAL PILOT<br />
25,0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 52<br />
Function Port size Flow (Max) Individual mounting<br />
3/2 NO-NC 1/8” - 1/4” 1.2C v<br />
add-on style<br />
cylinder ports<br />
in base<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
52A-xx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Pilot air<br />
Single operator<br />
Double operator<br />
NO valve<br />
2<br />
10<br />
12<br />
NC valve<br />
2<br />
10<br />
12<br />
10<br />
NO valve<br />
2<br />
12<br />
10<br />
NC valve<br />
2<br />
12<br />
Internal<br />
3 1<br />
52A-33-OOA-DM-DXXX-XXX<br />
3 1<br />
52A-13-OOA-DM-DXXX-XXX<br />
3 1<br />
52A-43-OOA-DM-DXXX-XXX<br />
3 1<br />
52A-23-OOA-DM-DXXX-XXX<br />
External<br />
52A-33-OOC-DM-DXXX-XXX<br />
52A-13-OOC-DM-DXXX-XXX<br />
52A-43-OOC-DM-DXXX-XXX<br />
52A-23-OOC-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X - X XX *<br />
Voltage<br />
Wire length<br />
Manual operator<br />
XX X X XX<br />
JA 120/60, 110/50<br />
JB 240/60, 220/50<br />
JC 24/60, 24/50<br />
DA 24VDC (5.4 W)<br />
FB 24VDC (1.8 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
A 18” (Flying leads)<br />
1 Non-locking<br />
KA<br />
J Connector<br />
2 Locking<br />
KD<br />
x Other Options<br />
x Other Options<br />
JB<br />
JD<br />
BA<br />
xx<br />
CBP052A-xxxxx-xx<br />
Electrical connection<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
Port size (NPTF)<br />
Pilot air<br />
Spacing st<strong>and</strong>ard<br />
19,5 mm<br />
Spacing 26 mm<br />
(Rectangular connector)<br />
1/8” SIDE PORT<br />
Internal<br />
CBP052A-00ABA-XX<br />
CBP052A-02ABA-XX<br />
1/4” SIDE PORT<br />
CBP052A-00ABD-XX<br />
CBP052A-02ABD-XX<br />
1/8” SIDE PORT<br />
External<br />
CBP052A-00EBA-XX<br />
CBP052A-02EBA-XX<br />
1/4” SIDE PORT<br />
CBP052A-00EBD-XX<br />
CBP052A-02EBD-XX<br />
1/8” BOTTOM PORT<br />
Internal<br />
CBP052A-00BBA-XX<br />
CBP052A-02BBA-XX<br />
1/4” BOTTOM PORT<br />
CBP052A-00BBD-XX<br />
CBP052A-02BBD-XX<br />
1/8” BOTTOM PORT<br />
External<br />
CBP052A-00FBA-XX<br />
CBP052A-02FBA-XX<br />
1/4” BOTTOM PORT<br />
CBP052A-00FBD-XX<br />
CBP052A-02FBD-XX<br />
Number of stations (03=3 stations) ** Other options available. Consult factory.<br />
O P T I O N S<br />
Note : add-a-unit stations may be added to above bars.<br />
Clic here for model numbers.<br />
52A-33-OOA-DM-DXXX-XXX<br />
clic for memory spring (replace by 6).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 52<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum to 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
7.3 mm<br />
1.2C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-52003. • Seal (x3) : 17013-01. • Mounting screw (x2) : 35043. • End plate kit (Internal) : M-52001-01.<br />
• End plate kit (External) : M-52002-01.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
10.0<br />
CL<br />
CL<br />
CL<br />
CL<br />
1/8" OR 1/4"<br />
PORTS AVAILABLE<br />
ON THE BOTTOM OR SIDE<br />
40.0<br />
2<br />
2<br />
2<br />
2<br />
102.3<br />
XX<br />
CL<br />
CL<br />
CL<br />
CL<br />
23.2<br />
21.0<br />
10.0<br />
96.0<br />
1<br />
12<br />
12<br />
12<br />
12<br />
1<br />
MODEL<br />
69.5<br />
6.5 DIA.<br />
2 MTG.<br />
HOLES<br />
1<br />
3<br />
10<br />
10<br />
10<br />
10<br />
3<br />
14.5<br />
29.0<br />
52.5<br />
3<br />
2<br />
2<br />
2<br />
2<br />
ZZ<br />
38.2<br />
25.0<br />
YY<br />
21.0<br />
10.8<br />
16.0<br />
3/8" N.P.T.F.<br />
2 PLACES<br />
BOTH ENDS<br />
1/8" OPTIONAL<br />
COMMON EXTERNAL<br />
PILOT<br />
YY<br />
CL<br />
CL<br />
XX<br />
CL<br />
CL<br />
PORT<br />
7.0<br />
TYP.<br />
ZZ<br />
19.5<br />
113<br />
1/8”<br />
36.0<br />
26<br />
119.5<br />
1/4”<br />
40.0<br />
Note: Bottom & side cylinder ports not available on the same station<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 52<br />
Function Port size Flow (Max) Circuit bar mounting<br />
3/2 NO-NC 1/8” - 1/4” 1.2C v<br />
add-a-unit<br />
stations for<br />
CBM052A bar<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
52A-xx-xxx-DM-Dxxx-xxx<br />
SOLENOID OPERATOR<br />
Port size<br />
Pilot air<br />
Single operator<br />
NO valve<br />
NC valve<br />
Double operator<br />
NO valve<br />
NC valve<br />
10<br />
2<br />
12<br />
10<br />
2<br />
12<br />
10<br />
2<br />
12<br />
10<br />
2<br />
12<br />
1/8” NPTF<br />
Internal<br />
3 1<br />
52A-31-COA-DM-DXXX-XXX<br />
52A-31-AOA-DM-DXXX-XXX<br />
3 1<br />
52A-11-AOA-DM-DXXX-XXX<br />
3 1<br />
52A-41-AOA-DM-DXXX-XXX<br />
3 1<br />
52A-21-AOA-DM-DXXX-XXX<br />
1/4” NPTF<br />
52A-31-BOA-DM-DXXX-XXX<br />
52A-11-BOA-DM-DXXX-XXX<br />
52A-41-BOA-DM-DXXX-XXX<br />
52A-21-BOA-DM-DXXX-XXX<br />
1/8” NPTF<br />
External<br />
52A-31-AOC-DM-DXXX-XXX<br />
52A-11-AOC-DM-DXXX-XXX<br />
52A-41-AOC-DM-DXXX-XXX<br />
52A-21-AOC-DM-DXXX-XXX<br />
1/4” NPTF<br />
52A-31-BOC-DM-DXXX-XXX<br />
52A-11-BOC-DM-DXXX-XXX<br />
52A-41-BOC-DM-DXXX-XXX<br />
52A-21-BOC-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X - X XX *<br />
XX Voltage<br />
X Wire length<br />
X<br />
Manual operator<br />
XX<br />
Electrical connection<br />
JA 120/60, 110/50<br />
A<br />
18” (Flying leads)<br />
1 Non-locking<br />
KA<br />
Square connector<br />
JB 240/60, 220/50<br />
J<br />
Connector<br />
2 Locking<br />
KD<br />
Square connector<br />
with light<br />
JC 24/60, 24/50<br />
x<br />
Other Options<br />
x<br />
Other Options<br />
JB<br />
Rectangular connector<br />
DA 24VDC (5.4 W)<br />
JD<br />
Rectangular connector<br />
with light<br />
FB 24VDC (1.8 W)<br />
BA<br />
Flying leads<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
CBM052A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard<br />
21 mm<br />
Spacing 26 mm<br />
(Rectangular connector)<br />
3/8” NPTF<br />
Internal<br />
CBM052A-01AEA-XX<br />
CBM052A-02AEA-XX<br />
External<br />
CBM052A-01CEA-XX<br />
CBM052A-02CEA-XX<br />
Number of stations (01=1 station)<br />
* * Other options available. Consult factory.<br />
O P T I O N S<br />
Note : add-a-unit stations available in lengths up to 4 stations (01, 02, 03 or 04).<br />
52A-31-AOA-DM-DXXX-XXX<br />
clic for memory spring (replace by 4).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 52<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum to 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
7.3 mm<br />
1.2C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04001. • Seal (x3) : 17015-01. • Mounting screw (x2) : 35043.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
CL CL CL CL<br />
40.0<br />
102.3<br />
XX<br />
CL CL CL CL<br />
1/8" OR 1/4"<br />
PORTS AVAILABLE<br />
ON THE BOTTOM OR SIDE<br />
23.2<br />
21.0<br />
10.0<br />
96.0<br />
35.0<br />
1 3<br />
12 12<br />
10<br />
10<br />
12<br />
10<br />
12<br />
10<br />
1<br />
3<br />
MODEL<br />
69.5<br />
52.5<br />
29.0<br />
14.5<br />
6.5 DIA.<br />
2 MTG.<br />
HOLES<br />
1 3<br />
38.2<br />
25.0<br />
YY<br />
21.0<br />
10.8<br />
16.0<br />
3/8" N.P.T.F.<br />
2 PLACES<br />
BOTH ENDS<br />
1/8" OPTIONAL<br />
COMMON EXTERNAL<br />
PILOT<br />
CL CL CL CL<br />
7.0<br />
TYP.<br />
YY<br />
19.5<br />
26<br />
XX<br />
113<br />
119.5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 52<br />
Function Port size Flow (Max) Individual mounting<br />
3/2 NO-NC 1/8” - 1/4” 1.2C v<br />
add-a-unit<br />
stations for<br />
CBP052A bar<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
52A-xx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Pilot air<br />
Single operator<br />
Double operator<br />
NO valve<br />
2<br />
10<br />
12<br />
NC valve<br />
2<br />
10<br />
12<br />
10<br />
NO valve<br />
2<br />
12<br />
10<br />
NC valve<br />
2<br />
12<br />
Internal<br />
3 1<br />
52A-33-OOA-DM-DXXX-XXX<br />
3 1<br />
52A-13-OOA-DM-DXXX-XXX<br />
3 1<br />
52A-43-OOA-DM-DXXX-XXX<br />
3 1<br />
52A-23-OOA-DM-DXXX-XXX<br />
External<br />
52A-33-OOC-DM-DXXX-XXX<br />
52A-13-OOC-DM-DXXX-XXX<br />
52A-43-OOC-DM-DXXX-XXX<br />
52A-23-OOC-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X - X XX *<br />
Voltage<br />
Wire length<br />
Manual operator<br />
XX X X XX<br />
JA 120/60, 110/50<br />
JB 240/60, 220/50<br />
JC 24/60, 24/50<br />
DA 24VDC (5.4 W)<br />
FB 24VDC (1.8 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
A 18” (Flying leads)<br />
1 Non-locking<br />
KA<br />
J Connector<br />
2 Locking<br />
KD<br />
x Other Options<br />
x Other Options<br />
JB<br />
JD<br />
BA<br />
xx<br />
CBP052A-xxxxx-xx<br />
Electrical connection<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
Port size (NPTF)<br />
Pilot air<br />
Spacing st<strong>and</strong>ard<br />
21 mm<br />
Spacing 26 mm<br />
(Rectangular connector)<br />
1/8” SIDE PORT<br />
Internal<br />
CBP052A-01AEA-XX<br />
CBP052A-02AEA-XX<br />
1/4” SIDE PORT<br />
CBP052A-01AED-XX<br />
CBP052A-02AED-XX<br />
1/8” SIDE PORT<br />
External<br />
CBP052A-01EEA-XX<br />
CBP052A-02EEA-XX<br />
1/4” SIDE PORT<br />
CBP052A-01EED-XX<br />
CBP052A-02EED-XX<br />
1/8” BOTTOM PORT<br />
Internal<br />
CBP052A-01BEA-XX<br />
CBP052A-02BEA-XX<br />
1/4” BOTTOM PORT<br />
CBP052A-01BED-XX<br />
CBP052A-02BED-XX<br />
1/8” BOTTOM PORT<br />
External<br />
CBP052A-01FEA-XX<br />
CBP052A-02FEA-XX<br />
1/4” BOTTOM PORT<br />
CBP052A-01FED-XX<br />
CBP052A-02FED-XX<br />
Number of stations (03=3 stations) ** Other options available. Consult factory.<br />
O P T I O N S<br />
Note : add-a-unit stations available in lengths up to<br />
4 stations (01, 02, 03 or 04).<br />
52A-33-OOA-DM-DXXX-XXX<br />
clic for memory spring (replace by 6).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 52<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum to 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
7.3 mm<br />
1.2C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-52003. • Seal (x3) : 17013-01. • Mounting screw (x2) : 35043.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
10.0<br />
CL<br />
CL<br />
CL<br />
CL<br />
1/8" OR 1/4"<br />
PORTS AVAILABLE<br />
ON THE BOTTOM OR SIDE<br />
40.0<br />
2<br />
2<br />
2<br />
2<br />
102.3<br />
XX<br />
CL<br />
CL<br />
CL<br />
CL<br />
23.2<br />
21.0<br />
10.0<br />
96.0<br />
1<br />
12<br />
12<br />
12<br />
12<br />
1<br />
MODEL<br />
69.5<br />
6.5 DIA.<br />
2 MTG.<br />
HOLES<br />
1<br />
3<br />
10<br />
10<br />
10<br />
10<br />
3<br />
52.5<br />
29.0<br />
14.5<br />
3<br />
2<br />
2<br />
2<br />
2<br />
ZZ<br />
38.2<br />
25.0<br />
YY<br />
21.0<br />
10.8<br />
16.0<br />
3/8" N.P.T.F.<br />
2 PLACES<br />
BOTH ENDS<br />
1/8" OPTIONAL<br />
COMMON EXTERNAL<br />
PILOT<br />
YY<br />
CL<br />
CL<br />
XX<br />
CL<br />
CL<br />
PORT<br />
7.0<br />
TYP.<br />
ZZ<br />
19.5<br />
113<br />
1/8”<br />
36.0<br />
26<br />
119.5<br />
1/4”<br />
40.0<br />
Note: Bottom & side cylinder ports not available on the same station<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Section 2 Options<br />
Consult “Precautions” before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Codification table for voltages / Wire length / Manual operator / Electrical connection<br />
VALVE CODE ➤<br />
D M - D XX X - X XX<br />
1 2 3 4<br />
OPTIONS AVAILABLE FOR<br />
- pilot operated valves 400, 52 & 92 Series<br />
Consult “Precautions”before use, installation or service of MAC Valves.
OPTIONS<br />
Back<br />
1. VOLTAGE<br />
- D XX X - X XX VOLTAGE<br />
DB 12 VDC (5.4 W)<br />
DC 12 VDC (7.5 W)<br />
DD 24 VDC (7.3 W)<br />
DE 12 VDC (12.7 W)<br />
DK 110 VDC (5.8 W)<br />
DJ 28 VDC (5.7 W)<br />
DL 64 VDC (6.0 W)<br />
DM 36 VDC (5.8 W)<br />
DN 6 VDC (6.0 W)<br />
DR 90 VDC (6,6 W)<br />
DS 110 VDC (7.3 W), 100 VDC (6.0 W)<br />
DT 75 VDC (5.6 W)<br />
DP 48 VDC (5.8 W)<br />
FA 12 VDC (1.8 W)<br />
FE 12 VDC (2.4 W)<br />
FF 24 VDC (2.4 W)<br />
JD 100/60, 100/50, 110/60<br />
2. WIRE LENGTH<br />
- D XX X - X XX WIRE LENGTH<br />
B 24”<br />
C 36”<br />
D 48”<br />
E 72”<br />
F 96”<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Back<br />
3. MANUAL OPERATOR<br />
- D XX X - X XX MANUAL OPERATOR<br />
0 No operator<br />
1 Non-locking recessed<br />
2 Locking recessed<br />
3 Non-locking extended<br />
4 Locking extended<br />
4. ELECTRICAL CONNECTION<br />
- D XX X - X XX ELECTRICAL CONNECTION<br />
BA Flying leads<br />
BK BA with protection diode<br />
BL BA with protection varistor<br />
CA 1/2" NPS conduit<br />
JB Rectangular connector<br />
JD Rectangular connector with light<br />
JM Rectangular connector, male only<br />
KA Square connector<br />
KB Square connector with protection diode<br />
KC Square connector with protection varistor<br />
KD Square connector with light<br />
KE Square connector with light <strong>and</strong> protection diode<br />
KF Square connector with light <strong>and</strong> protection varistor<br />
KJ Square connector (male only)<br />
KK Square connector with protection diode (male only)<br />
KL Square connector with protection varistor (male only)<br />
TA Dual tabs<br />
TB TA with protection diode<br />
TD TA with light<br />
TE TA with light <strong>and</strong> protection diode<br />
TJ Dual tabs (male only)<br />
TK TJ with protection diode<br />
TM TJ with light<br />
TN TJ with light <strong>and</strong> protection diode<br />
*DN Plug-in with diode<br />
*DP Plug-in with M.O.V.<br />
*DH Plug-in with diode & ground<br />
*DJ Plug-in with M.O.V & ground<br />
* These options only apply to the 92 series. All others are for the 400 <strong>and</strong> 52 series.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
PIN #6<br />
PIN #9<br />
MOD. SD09<br />
PIN #1<br />
PIN #5<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 9<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 7 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 2 common wires<br />
PIN #9<br />
PIN #15<br />
MOD. SD15<br />
PIN #1<br />
PIN #8<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 15<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 12 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 3 common wires<br />
PIN #14<br />
PIN #25<br />
MOD. SD25<br />
PIN #1<br />
PIN #13<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 25<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 20 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 5 common wires<br />
Note : Use desired MOD. number after circuit bar part number
O p t i o n s<br />
OPTIONS<br />
Connector termination details<br />
CONNECTOR<br />
SOL 1<br />
SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />
Single solenoid circuit bar<br />
SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />
CONNECTOR<br />
SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />
Double solenoid circuit bar<br />
SD09 SD15 SD25<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
8<br />
COMMON (+)<br />
13<br />
COMMON (+)<br />
21<br />
COMMON (+)<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
9<br />
COMMON (+)<br />
8<br />
SOL. 8<br />
8<br />
SOL. 8<br />
14<br />
COMMON (+)<br />
22<br />
COMMON (+)<br />
9<br />
SOL. 9<br />
9<br />
SOL. 9<br />
10 SOL. 10<br />
10 SOL. 10<br />
11<br />
SOL. 11<br />
11<br />
SOL. 11<br />
12 SOL. 12<br />
12 SOL. 12<br />
15<br />
COMMON (+)<br />
23<br />
COMMON (+)<br />
13<br />
SOL. 13<br />
14 SOL. 14<br />
15<br />
SOL. 15<br />
16 SOL. 16<br />
24<br />
COMMON (+)<br />
17<br />
18 SOL. 18<br />
19<br />
20 SOL. 20<br />
SOL. 17<br />
SOL. 19<br />
25<br />
COMMON (+)
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Circuit bar mounting<br />
non plug-in<br />
cylinder ports<br />
in base<br />
non plug-in<br />
cylinder ports<br />
in valve<br />
plug-in<br />
plug-in<br />
with F. C.<br />
plug-in<br />
with Pr. Reg.<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
add-on style<br />
plug-in<br />
add-on style<br />
plug-in<br />
with F. C.<br />
add-on style<br />
plug-in<br />
with Pr. Reg.<br />
add-on style<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
plug-in<br />
add-a-unit<br />
stations<br />
plug-in<br />
add-a-unit<br />
stations<br />
with F. C.<br />
plug-in<br />
add-a-unit<br />
stations<br />
with Pr. Reg.<br />
plug-in<br />
add-a-unit<br />
stations with<br />
F. C. <strong>and</strong> Pr. Reg.<br />
plug-in with<br />
pre-wired<br />
connector<br />
plug-in with<br />
F. C. <strong>and</strong><br />
pre-wired<br />
connector<br />
plug-in with<br />
Pr. Reg. <strong>and</strong><br />
pre-wired<br />
connector<br />
din rail,<br />
plug-in with<br />
pre-wired<br />
connector<br />
Manual operator<br />
Armature<br />
Coil<br />
Push Pin<br />
B A<br />
IN<br />
EA<br />
“D” seal<br />
4 Balanced poppets<br />
Valve spring<br />
EB<br />
SERIES FEATURES<br />
• High force MACSOLENOID ® .<br />
• 10mm direct operated.<br />
• # 10-32 or M5 ports.<br />
• Rated for lubricated or non-lubricated service.<br />
• Cylinder ports in valve or in circuit bar.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.093C v<br />
non plug-in<br />
cylinder ports<br />
in base<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-Gxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Valve less base<br />
Valve<br />
44B-LOO-GXXX-XXX<br />
Valve for use with<br />
external flow controls<br />
B A<br />
IN EA B EB A<br />
IN EA<br />
EB<br />
44B-MOO-GXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
A 18”<br />
1 Non-locking<br />
BA<br />
Flying leads<br />
DC 24VDC (1.8 W)<br />
C 36”<br />
BT<br />
Flying leads<br />
with light<br />
DD 24VDC (2.5 W)<br />
x<br />
Other Options<br />
KA<br />
Mini connector<br />
DF 24VDC (4.0 W)<br />
KT<br />
Mini connector<br />
with light<br />
xx<br />
Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
EBP44B-xxxx-xx<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
M5<br />
# 10-32<br />
EBP44B-001D-XX<br />
EBP44B-001B-XX<br />
EBP44B-002D-XX<br />
EBP44B-002B-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.093 C v , 2.5 W : 0.077 C v , 1,8 W : 0.057 C v , 1.0 W : 0.048 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 3.4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult Factory.<br />
DIMENSIONS<br />
M5 VALVE MTG. SCR.<br />
24,8<br />
59,5<br />
10,0<br />
B<br />
B<br />
16,25<br />
5,3<br />
15,0<br />
A<br />
A<br />
15,0<br />
71,2<br />
15,5<br />
2,5<br />
15,5<br />
10,5 5,0<br />
EA IN EB<br />
15,5<br />
10,5<br />
10,5<br />
1/8” NPTF PORTS<br />
18,3<br />
44,8<br />
5,5<br />
4 Ø 4,3<br />
56,3<br />
57,3<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC # 10-32 - 1/8” 0.093C v<br />
non plug-in<br />
cylinder ports<br />
in valve<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-Gxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Valve port size<br />
M5<br />
# 10-32<br />
Valve<br />
44B-ABA-GXXX-XXX<br />
44B-AAA-GXXX-XXX<br />
Valve for use with<br />
external flow controls<br />
B A<br />
IN EA B EB A<br />
IN EA<br />
EB<br />
44B-BBA-GXXX-XXX<br />
44B-BAA-GXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
A 18”<br />
1 Non-locking<br />
BA<br />
Flying leads<br />
DC 24VDC (1.8 W)<br />
C 36”<br />
BT<br />
Flying leads<br />
with light<br />
DD 24VDC (2.5 W)<br />
x<br />
Other Options<br />
KA<br />
Mini connector<br />
DF 24VDC (4.0 W)<br />
KT<br />
Mini connector<br />
with light<br />
xx<br />
Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
EBM44A-xxxx-xx<br />
Port size<br />
COMMON INLET & EXHAUST<br />
# 10-32<br />
1/8” NPTF<br />
EBM44A-001B-XX<br />
EBM44A-002A-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.093 C v , 2.5 W : 0.077 C v , 1,8 W : 0.057 C v , 1.0 W : 0.048 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 3.5 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit (M5) : M-44001-21. • Valve mounting kit (1/8") : M-44001-01. • Blanking plate : 30426-A.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult Factory.<br />
DIMENSIONS<br />
J<br />
K<br />
A B<br />
B<br />
Ø 4,2 MTG. HOLES<br />
H<br />
A<br />
D<br />
E<br />
F<br />
G<br />
14,0<br />
C L C L<br />
10,50<br />
4,00<br />
C<br />
38,5<br />
Port size<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
J<br />
K<br />
1/8”<br />
16.0<br />
47.5<br />
69.2<br />
8.5<br />
24.0<br />
39.5<br />
48.0<br />
8.0<br />
31.85<br />
16.15<br />
M5<br />
12.0<br />
43.5<br />
63.2<br />
5.0<br />
17.0<br />
29.0<br />
34.0<br />
6.0<br />
23.00<br />
11.00<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.09C v plug-in<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-LOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
M5<br />
# 10-32<br />
ECD044B-00xxx-AOxx<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECD044B-001AD-AOXX<br />
ECD044B-001AB-AOXX<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECD044B-002AD-AOXX<br />
ECD044B-002AB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
clic for multi-pin connector option (9, 15 or 25).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
11.4<br />
18.5<br />
61.2<br />
L<br />
24.5<br />
13.8<br />
90.7<br />
26.0<br />
38.6<br />
84.0<br />
33.5<br />
23.0<br />
40.0<br />
32.3<br />
19.9<br />
5.0<br />
13.0<br />
20.1<br />
20.5<br />
24.9<br />
17.7<br />
22.5<br />
33.0<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
55.5<br />
3<br />
66.0<br />
4<br />
76.5<br />
5<br />
87.0<br />
6<br />
97.5<br />
7 8 9 10<br />
108.0 118.5 129.0 139.5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.08C v<br />
plug-in<br />
with F. C.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-MOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />
Port size<br />
M5<br />
# 10-32<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECD044B-005AD-AOXX<br />
ECD044B-005AB-AOXX<br />
ECD044B-00xxx-AOxx<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECD044B-006AD-AOXX<br />
ECD044B-006AB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
clic for multi-pin connector option (9, 15 or 25).<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Flow control needle (x2): N-44002.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
11.4<br />
18.5<br />
61.2<br />
24.5<br />
13.8<br />
90.7<br />
26.0<br />
38.6<br />
84.0<br />
33.5<br />
23.0<br />
40.0<br />
32.3<br />
19.9<br />
5.0<br />
17.7<br />
13.0<br />
20.1<br />
20.5<br />
24.9<br />
22.5<br />
33.0<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
55.5<br />
3<br />
66.0<br />
4<br />
76.5<br />
5<br />
87.0<br />
6<br />
97.5<br />
7 8 9 10<br />
108.0 118.5 129.0 139.5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.08C v<br />
plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-LOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS** (to be ordered separately)<br />
ECD044B-00xxx-AOxx<br />
Port size<br />
M5<br />
# 10-32<br />
Bottom cylinder ports<br />
(10,5 mm)<br />
ECD044B-004AD-A0-XX<br />
ECD044B-004AB-A0-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
clic for multi-pin connector option (9, 15 or 25).<br />
** Pressure Regulators :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Pressure range regulators : (0-100 PSI).<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
61.2<br />
18.5<br />
11.4<br />
144.3<br />
24.5<br />
13.8<br />
90.7<br />
26.0<br />
38.6<br />
84.0<br />
32.3<br />
19.9<br />
13.0<br />
20.5<br />
33.5<br />
20.1<br />
24.9<br />
23.0<br />
40.0<br />
5.0<br />
17.7<br />
22.5<br />
33.0<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
55.5<br />
3<br />
66.0<br />
4<br />
76.5<br />
5<br />
87.0<br />
6<br />
97.5<br />
7 8 9 10<br />
108.0 118.5 129.0 139.5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.07C v<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-MOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
ECD044B-00xxx-AOxx<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS** (pressure regulators to be ordered separately)<br />
Port size<br />
M5<br />
# 10-32<br />
Bottom cylinder ports<br />
(10,5 mm)<br />
ECD044B-007AD-A0-XX<br />
ECD044B-007AB-A0-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
clic for multi-pin connector option (9, 15 or 25).<br />
** Pressure Regulators :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.07 C v , 2.5 W : 0.06 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Pressure range regulators : (0-100 PSI).<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
L<br />
61.2<br />
18.5<br />
11.4<br />
24.5<br />
144.3<br />
13.8<br />
90.7<br />
26.0<br />
38.6<br />
84.0<br />
32.3<br />
19.9<br />
13.0<br />
20.5<br />
33.5<br />
20.1<br />
24.9<br />
23.0<br />
40.0<br />
5.0<br />
17.7<br />
22.5<br />
33.0<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
55.5<br />
3<br />
66.0<br />
4<br />
76.5<br />
5<br />
87.0<br />
6<br />
97.5<br />
7 8 9 10<br />
108.0 118.5 129.0 139.5<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.09C v<br />
add-on style<br />
plug-in<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-LOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
M5<br />
# 10-32<br />
ECD044B-00xxx-AOxx<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECD044B-001BD-AOXX<br />
ECD044B-001BB-AOXX<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECD044B-002BD-AOXX<br />
ECD044B-002BB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
clic for multi-pin connector option (9, 15 or 25).<br />
add-a-unit stations may be added to above bars.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
24.5<br />
41.5<br />
10.5<br />
10.5<br />
15.5<br />
20.0<br />
18.5<br />
11.3<br />
13.8<br />
26.0<br />
EXH<br />
90.7<br />
38.6<br />
IN<br />
64.2<br />
EXH<br />
84.0<br />
60.5<br />
B<br />
A A<br />
B<br />
B<br />
A<br />
A<br />
A<br />
19.9<br />
20.9<br />
31.3<br />
32.3<br />
60.5<br />
17.7<br />
5.0<br />
A<br />
A<br />
13.0<br />
B<br />
B B<br />
B<br />
20.5<br />
10.5<br />
25.0<br />
20.7<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.08C v<br />
add-on style<br />
plug-in<br />
with F. C.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-MOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />
Port size<br />
M5<br />
# 10-32<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECD044B-005BD-AOXX<br />
ECD044B-005BB-AOXX<br />
ECD044B-00xxx-AOxx<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECD044B-006BD-AOXX<br />
ECD044B-006BB-AOXX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
clic for multi-pin connector option (9, 15 or 25).<br />
add-a-unit stations may be added to above bars.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Flow control needle (x2): N-44002.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
41.5<br />
15.0<br />
15.0<br />
15.5<br />
24.5<br />
20.0<br />
18.5<br />
11.3<br />
13.8<br />
90.7<br />
26.0<br />
EXH<br />
38.6<br />
IN<br />
84.0<br />
64.2<br />
EXH<br />
60.5 17.7 5.0<br />
60.5<br />
A<br />
A<br />
A<br />
B<br />
A<br />
B<br />
B<br />
A<br />
19.9<br />
20.9<br />
31.3<br />
32.3<br />
B<br />
B<br />
A<br />
A<br />
B<br />
B<br />
13.0<br />
20.5<br />
10.9<br />
20.6<br />
25.0<br />
10.5<br />
4.4<br />
5.1<br />
23.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.08C v<br />
add-on style<br />
plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-LOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS** (to be ordered separately)<br />
ECD044B-00xxx-AOxx<br />
Port size<br />
M5<br />
# 10-32<br />
Bottom cylinder ports<br />
(10,5 mm)<br />
ECD044B-004BD-A0-XX<br />
ECD044B-004BB-A0-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
clic for multi-pin connector option (9, 15 or 25).<br />
add-a-unit stations may be added to above bars.<br />
** Pressure Regulators :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Pressure range regulators : (0-100 PSI).<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
41.5<br />
10.5<br />
10.5<br />
24.5<br />
20.0<br />
18.5<br />
11.3<br />
15.5<br />
144.3<br />
13.8<br />
90.7<br />
38.6<br />
64.2<br />
26.0<br />
IN<br />
EXH<br />
EXH<br />
25.0<br />
20.5<br />
13.0<br />
10.5<br />
84.0<br />
K<br />
C<br />
O<br />
L<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
- +<br />
A<br />
K<br />
O C<br />
L<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
-<br />
+<br />
A<br />
A<br />
A<br />
60.5<br />
17.7<br />
5.0<br />
60.5<br />
B<br />
B<br />
B<br />
19.9<br />
20.9<br />
31.3<br />
32.3<br />
20.7<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.07C v<br />
plug-in<br />
with Pr. Reg.<br />
add-on style<br />
<strong>and</strong> F. C.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-MOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
ECD044B-00xxx-AOxx<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS** (pressure regulators to be ordered separately)<br />
Port size<br />
M5<br />
# 10-32<br />
Bottom cylinder ports<br />
(10,5 mm)<br />
ECD044B-007BD-A0-XX<br />
ECD044B-007BB-A0-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
clic for multi-pin connector option (9, 15 or 25).<br />
add-a-unit stations may be added to above bars.<br />
** Pressure Regulators :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
IN<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.07 C v , 2.5 W : 0.06 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Pressure range regulators : (0-100 PSI).<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
87.0<br />
144.3<br />
90.7<br />
26.0<br />
13.8<br />
EXH<br />
10.5<br />
4.4<br />
38.6<br />
5.1<br />
84.0<br />
64.2<br />
EXH<br />
25.0<br />
20.5<br />
13.0<br />
41.5<br />
15.5<br />
11.4<br />
15.0<br />
15.0<br />
18.5<br />
60.5<br />
17.7<br />
5.0<br />
20.0<br />
24.5<br />
60.5<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
19.9 20.9 31.3 32.3<br />
10.9<br />
20.6<br />
23.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 M5 - #10-32 0.09C v<br />
plug-in<br />
add-a-unit<br />
stations<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-LOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
ECD044B-00xxx-AOxx<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
M5<br />
# 10-32<br />
ECD044B-001CD-AOXX<br />
ECD044B-001CB-AOXX<br />
ECD044B-002CD-AOXX<br />
ECD044B-002CB-AOXX<br />
Number of stations (03=3 stations) - Maximum length is 4 stations<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
when add-a-unit stations are added to bars with a multi-pin connector,<br />
MOD. SD03 should be included with add-a-unit model number.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
24.5<br />
41.5<br />
10.5<br />
10.5<br />
15.5<br />
20.0<br />
18.5<br />
11.3<br />
13.8<br />
26.0<br />
EXH<br />
90.7<br />
38.6<br />
IN<br />
64.2<br />
EXH<br />
84.0<br />
60.5<br />
B<br />
A A<br />
B<br />
B<br />
A<br />
A<br />
A<br />
19.9<br />
20.9<br />
31.3<br />
32.3<br />
60.5<br />
17.7<br />
5.0<br />
A<br />
A<br />
13.0<br />
B<br />
B B<br />
B<br />
20.5<br />
10.5<br />
25.0<br />
20.7<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 M5 - #10-32 0.08C v<br />
add-a-unit<br />
stations<br />
plug-in<br />
with F. C.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-MOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />
Port size<br />
Side cylinder ports<br />
ECD044B-00xxx-AOxx<br />
Bottom cylinder ports<br />
M5<br />
# 10-32<br />
ECD044B-005CD-AOXX<br />
ECD044B-005CB-AOXX<br />
ECD044B-006CD-AOXX<br />
ECD044B-006CB-AOXX<br />
Number of stations (03=3 stations) - Maximum length is 4 stations<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
when add-a-unit stations are added to bars with a multi-pin connector,<br />
MOD. SD03 should be included with add-a-unit model number.<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Flow control needle (x2): N-44002.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
41.5<br />
15.0<br />
15.0<br />
15.5<br />
24.5<br />
20.0<br />
18.5<br />
11.3<br />
13.8<br />
90.7<br />
26.0<br />
EXH<br />
38.6<br />
IN<br />
84.0<br />
64.2<br />
EXH<br />
60.5 17.7 5.0<br />
60.5<br />
A<br />
A<br />
A<br />
B<br />
A<br />
B<br />
B<br />
A<br />
19.9<br />
20.9<br />
31.3<br />
32.3<br />
B<br />
B<br />
A<br />
A<br />
B<br />
B<br />
13.0<br />
20.5<br />
10.9<br />
20.6<br />
25.0<br />
10.5<br />
4.4<br />
5.1<br />
23.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 M5 - #10-32 0.08C v<br />
add-a-unit<br />
stations<br />
plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-LOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />
Port size<br />
M5<br />
# 10-32<br />
ECD044B-00xxx-AOxx<br />
Bottom cylinder ports<br />
(10,5 mm)<br />
ECD044B-004CD-AOXX<br />
ECD044B-004CB-AOXX<br />
Number of stations (03=3 stations) - Maximum length is 4 stations<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
when add-a-unit stations are added to bars with a multi-pin connector,<br />
MOD. SD03 should be included with add-a-unit model number.<br />
** Regulator ordered separately-see below :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Pressure range regulators : (0-100 PSI).<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
24.5<br />
20.0<br />
41.5<br />
10.5<br />
10.5<br />
18.5<br />
11.3<br />
15.5<br />
144.3<br />
13.8<br />
90.7<br />
38.6<br />
64.2<br />
26.0<br />
IN<br />
EXH<br />
EXH<br />
25.0<br />
20.5<br />
13.0<br />
10.5<br />
84.0<br />
K<br />
C<br />
O<br />
L<br />
K<br />
C<br />
O<br />
L<br />
- +<br />
- +<br />
A<br />
K<br />
O C<br />
L<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
-<br />
+<br />
A<br />
A<br />
A<br />
60.5<br />
17.7<br />
5.0<br />
60.5<br />
B<br />
B<br />
B<br />
19.9<br />
20.9<br />
31.3<br />
32.3<br />
20.7<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 M5 - #10-32 0.07C v<br />
add-a-unit<br />
stations with<br />
plug-in<br />
F. C. <strong>and</strong> Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-MOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
ECD044B-00xxx-AOxx<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS ** (pressure regulators to be ordered separately)<br />
Port size<br />
M5<br />
# 10-32<br />
Bottom cylinder ports<br />
(10,5 mm)<br />
ECD044B-007CD-AOXX<br />
ECD044B-007CB-AOXX<br />
Number of stations (03=3 stations) - Maximum length is 4 stations<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
when add-a-unit stations are added to bars with a multi-pin connector,<br />
MOD. SD03 should be included with add-a-unit model number.<br />
** Regulator ordered separately-see below :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
Consult “Precautions” before use, installation or service of MAC Valves.
IN<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.07 C v , 2.5 W : 0.06 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Pressure range regulators : (0-100 PSI).<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />
DIMENSIONS<br />
87.0<br />
144.3<br />
90.7<br />
26.0<br />
13.8<br />
EXH<br />
10.5<br />
4.4<br />
38.6<br />
5.1<br />
84.0<br />
64.2<br />
EXH<br />
25.0<br />
20.5<br />
13.0<br />
41.5<br />
15.5<br />
11.4<br />
15.0<br />
15.0<br />
18.5<br />
60.5<br />
17.7<br />
5.0<br />
20.0<br />
24.5<br />
60.5<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
K<br />
+<br />
O C<br />
L<br />
-<br />
19.9 20.9 31.3 32.3<br />
10.9<br />
20.6<br />
23.0<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32, 0.10C v<br />
4 mm tube receptacle<br />
plug-in with<br />
pre-wired<br />
connector<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-LOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
ECF44B-00xxx-xxxx<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
Port size<br />
M5<br />
# 10-32<br />
4 mm tube receptacle<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECF44B-00BDA-ZZXX<br />
ECF44B-00BBA-ZZXX<br />
ECF44B-00BEA-ZZXX<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECF44B-00CDA-ZZXX<br />
ECF44B-00CBA-ZZXX<br />
---------<br />
Number of stations (03=3 stations)<br />
** Other options available Consult factory.<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
ZZ Connector<br />
LA 9 Pin Sub D*<br />
LB 15 Pin Sub D*<br />
LC 25 Pin Sub D*<br />
LD 10 Pin Ribbon Cable**<br />
LE 16 Pin Ribbon Cable**<br />
LF 20 Pin Ribbon Cable**<br />
LG 26 Pin Ribbon Cable**<br />
LH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
Consult “Precautions” before use, installation or service of MAC Valves.<br />
L=Left Side; R=Right Side<br />
ZZ Connector<br />
RA 9 Pin Sub D*<br />
RB 15 Pin Sub D*<br />
RC 25 Pin Sub D*<br />
RD 10 Pin Ribbon Cable**<br />
RE 16 Pin Ribbon Cable**<br />
RF 20 Pin Ribbon Cable**<br />
RG 26 Pin Ribbon Cable**<br />
RH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
* MIL. Spec; MIL-C-24308<br />
** MIL. Spec; MIL-C-83503<br />
Note: Left <strong>and</strong> right end is determined by facing conduit passage.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP threads.<br />
DIMENSIONS<br />
83.5<br />
8.7<br />
3.5<br />
2.9<br />
13.3<br />
EXH<br />
76.2<br />
70.4<br />
14.9<br />
13.6<br />
EXH<br />
IN<br />
10.5 17.4<br />
22.0<br />
A<br />
A<br />
10.6<br />
10.5<br />
49.5<br />
63.5<br />
2.8<br />
13.2<br />
51.0<br />
B<br />
B<br />
B<br />
B<br />
A<br />
A<br />
A<br />
B<br />
A A<br />
B<br />
B<br />
A<br />
B<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.09C v<br />
F. C. <strong>and</strong><br />
pre-wired<br />
plug-in with<br />
connector<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-MOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS **<br />
Port size<br />
M5<br />
# 10-32<br />
ECF44B-00xxx-xxxx<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECF44B-00EDA-ZZXX<br />
ECF44B-00EBA-ZZXX<br />
Number of stations (03=3 stations)<br />
** Other options available Consult factory.<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
ZZ Connector<br />
LA 9 Pin Sub D*<br />
LB 15 Pin Sub D*<br />
LC 25 Pin Sub D*<br />
LD 10 Pin Ribbon Cable**<br />
LE 16 Pin Ribbon Cable**<br />
LF 20 Pin Ribbon Cable**<br />
LG 26 Pin Ribbon Cable**<br />
LH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
Consult “Precautions” before use, installation or service of MAC Valves.<br />
L=Left Side; R=Right Side<br />
ZZ Connector<br />
RA 9 Pin Sub D*<br />
RB 15 Pin Sub D*<br />
RC 25 Pin Sub D*<br />
RD 10 Pin Ribbon Cable**<br />
RE 16 Pin Ribbon Cable**<br />
RF 20 Pin Ribbon Cable**<br />
RG 26 Pin Ribbon Cable**<br />
RH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
* MIL. Spec; MIL-C-24308<br />
** MIL. Spec; MIL-C-83503<br />
Note: Left <strong>and</strong> right end is determined by facing conduit passage.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Flow control needle (x2): N-44002.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP threads.<br />
DIMENSIONS<br />
83.5<br />
76.2<br />
70.4<br />
13.3<br />
14.9<br />
13.6<br />
EXH EXH<br />
IN<br />
22.0<br />
B<br />
B<br />
B<br />
B<br />
49.5<br />
63.5<br />
2.9<br />
3.5<br />
8.7<br />
A<br />
A<br />
A<br />
A<br />
10.6<br />
51.0<br />
10.5<br />
17.4<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32 0.09C v<br />
Pr. Reg. <strong>and</strong><br />
pre-wired<br />
plug-in with<br />
connector<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-LOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />
Port size<br />
M5<br />
# 10-32<br />
ECF44B-00xxx-xxxx<br />
Bottom cylinder ports<br />
(10.5 mm)<br />
ECF44B-00GDA-ZZXX<br />
ECF44B-00GBA-ZZXX<br />
Number of stations (03=3 stations)<br />
** Other options available Consult factory.<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
** Pressure Regulators :<br />
PR44A-AOxx<br />
Y=A (no gage port)<br />
Y=B (with gage port)<br />
X=A (0 to 100 PSI)<br />
X=B (0 to 60 PSI)<br />
X=C (0 to 40 PSI)<br />
X=D (0 to 15 PSI)<br />
ZZ Connector<br />
LA 9 Pin Sub D*<br />
LB 15 Pin Sub D*<br />
LC 25 Pin Sub D*<br />
LD 10 Pin Ribbon Cable**<br />
LE 16 Pin Ribbon Cable**<br />
LF 20 Pin Ribbon Cable**<br />
LG 26 Pin Ribbon Cable**<br />
LH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
Consult “Precautions” before use, installation or service of MAC Valves.<br />
L=Left Side; R=Right Side<br />
ZZ Connector<br />
RA 9 Pin Sub D*<br />
RB 15 Pin Sub D*<br />
RC 25 Pin Sub D*<br />
RD 10 Pin Ribbon Cable**<br />
RE 16 Pin Ribbon Cable**<br />
RF 20 Pin Ribbon Cable**<br />
RG 26 Pin Ribbon Cable**<br />
RH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
* MIL. Spec; MIL-C-24308<br />
** MIL. Spec; MIL-C-83503<br />
Note: Left <strong>and</strong> right end is determined by facing conduit passage.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Pressure range regulator (0-100 PSI)<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator : N-44003.<br />
• Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP threads.<br />
DIMENSIONS<br />
83.5<br />
136.5<br />
70.4<br />
13.3<br />
14.9<br />
13.6<br />
EXH EXH<br />
IN<br />
22.0<br />
K<br />
O C<br />
L<br />
K<br />
O C<br />
L<br />
K<br />
O C<br />
L<br />
K<br />
O C<br />
L<br />
-<br />
+<br />
-<br />
+<br />
-<br />
+<br />
-<br />
+<br />
B<br />
B<br />
B<br />
B<br />
49.5<br />
63.5<br />
2.9<br />
3.5<br />
8.7<br />
A<br />
A<br />
A<br />
A<br />
10.6<br />
51.0<br />
10.5<br />
17.4<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 44<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2, 3/2 NO-NC M5 - #10-32, 0.10C v<br />
4 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. 10 mm valve, direct solenoid operated.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Flow is specifically adjusted on each valve.<br />
7. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
din rail,<br />
plug-in with<br />
pre-wired<br />
connector<br />
HOW TO ORDER<br />
44B-xxx-GxxO-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
Single operator<br />
B<br />
A<br />
Valve less base<br />
EB<br />
IN EA<br />
44B-LOO-GXXO-XXX<br />
SOLENOID OPERATOR ➤<br />
G XX O- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (1.0 W)<br />
DC 24VDC (1.8 W)<br />
DD 24VDC (2.5 W)<br />
1 Non-locking<br />
DF 24VDC (4.0 W)<br />
DV Plug-in with light <strong>and</strong> suppression diode<br />
xx Other Options<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
ECF44B-00xxx-xxxx<br />
DJ<br />
DT<br />
DE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
Port size<br />
M5<br />
# 10-32<br />
4 mm tube receptacle<br />
Side cylinder ports<br />
(10.5 mm)<br />
ECF44B-00BDB-ZZXX<br />
ECF44B-00BBB-ZZXX<br />
ECF44B-00BEB-ZZXX<br />
Number of stations (03=3 stations)<br />
Din rail spec. (EN50 022)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
ZZ Connector<br />
LA 9 Pin Sub D*<br />
LB 15 Pin Sub D*<br />
LC 25 Pin Sub D*<br />
LD 10 Pin Ribbon Cable**<br />
LE 16 Pin Ribbon Cable**<br />
LF 20 Pin Ribbon Cable**<br />
LG 26 Pin Ribbon Cable**<br />
LH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
Consult “Precautions” before use, installation or service of MAC Valves.<br />
L=Left Side; R=Right Side<br />
ZZ Connector<br />
RA 9 Pin Sub D*<br />
RB 15 Pin Sub D*<br />
RC 25 Pin Sub D*<br />
RD 10 Pin Ribbon Cable**<br />
RE 16 Pin Ribbon Cable**<br />
RF 20 Pin Ribbon Cable**<br />
RG 26 Pin Ribbon Cable**<br />
RH 3/8” NPSM Conduit Port<br />
St<strong>and</strong>ard Base Wires<br />
* MIL. Spec; MIL-C-24308<br />
** MIL. Spec; MIL-C-83503<br />
Note: Left <strong>and</strong> right end is determined by facing conduit passage.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 44<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 4 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
1.8 mm<br />
4 W : 0.10 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
4 W - 2.5 W - 1.8 W - 1.0 W<br />
Energize : 4 ms<br />
De-energize : 1.5 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Base wire Plug-in protector : 24180.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP threads.<br />
DIMENSIONS<br />
83.5<br />
8.7<br />
3.5<br />
2.9<br />
76.2<br />
70.4<br />
13.3<br />
14.9<br />
13.6<br />
EXH EXH<br />
IN<br />
54.4<br />
49.5<br />
63.5<br />
60.5<br />
9.8<br />
42.6<br />
10.5<br />
2.8<br />
13.2<br />
5.4<br />
B<br />
B<br />
B<br />
B<br />
A<br />
A<br />
A<br />
A<br />
Consult “Precautions” before use, installation or service of MAC Valves.
Section 2 Options<br />
Consult “Precautions” before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Codification table for voltages / Manual operator / Electrical connection<br />
VALVE CODE ➤<br />
- G XX X - X XX<br />
1 2 3 4<br />
OPTIONS AVAILABLE FOR<br />
- solenoid valves 34 & 44 Series<br />
Consult “Precautions”before use, installation or service of MAC Valves.
OPTIONS<br />
Back<br />
1. VOLTAGE (type 34 Series)<br />
-G XX X - X XX VOLTAGE<br />
DC 24 VDC (1,8 W)<br />
DD 24 VDC (2,5 W)<br />
DE 24 VDC (3,0 W)<br />
DF 24 VDC (4,0 W)<br />
DJ 12 VDC (1,8 W)<br />
DK 12 VDC (2,5 W)<br />
DM 12 VDC (3,0 W)<br />
DN 12 VDC (4,0 W)<br />
1. VOLTAGE (type 44 Series)<br />
-G XX X - X XX VOLTAGE<br />
DA 24 VDC (1,0 W)<br />
DC 24 VDC (1,8 W)<br />
DD 24 VDC (2,5 W)<br />
DF 24 VDC (4,0 W)<br />
DG 12 VDC (1,0 W)<br />
DJ 12 VDC (1,8 W)<br />
DK 12 VDC (2,5 W)<br />
DN 12 VDC (4,0 W)<br />
2. WIRE LENGTH (Common options for 34 & 44 Series)<br />
-G XX X - X XX WIRE LENGTH<br />
A 18”<br />
B 24”<br />
C 36”<br />
D 48”<br />
E 72”<br />
F 96”<br />
G 120”<br />
H 144”<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Back<br />
3. MANUAL OPERATOR (COMMON OPTIONS FOR 34 & 44 SERIES)<br />
-G XX X - X XX MANUAL OPERATOR<br />
1 Non-locking recessed<br />
3 Non-locking extended<br />
4. ELECTRICAL CONNECTION (COMMON OPTIONS FOR 34 & 44 SERIES)<br />
-G XX X - X XX NO CONNECTOR<br />
BA Flying leads<br />
BB BA with ground wire<br />
BC BA with light<br />
BD BA with light <strong>and</strong> ground wire<br />
BE BA with suppression diode<br />
BF BA with suppression diode <strong>and</strong> ground wire<br />
BG BA with suppression diode <strong>and</strong> light<br />
BH BA with suppression diode, light <strong>and</strong> ground wire<br />
BN BA with suppression diode <strong>and</strong> blocking diode<br />
BP BA with suppression diode, blocking diode <strong>and</strong> ground wire<br />
BR BA with suppression diode, blocking diode <strong>and</strong> light<br />
BS BA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />
BT BA with light<br />
BU BA with light <strong>and</strong> ground wire<br />
BV BA with suppression diode <strong>and</strong> light<br />
BW BA with suppression diode, light <strong>and</strong> ground wire<br />
BX BA with suppression diode, blocking diode <strong>and</strong> light<br />
BY BA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />
-G XX X - X XX PLUG-IN CONNECTOR<br />
KA Mini connector with flying leads<br />
KB KA with ground wire<br />
KE KA with suppression diode<br />
KF KA with suppression diode <strong>and</strong> ground wire<br />
KJ Mini connector for KA option<br />
KM Mini connector for KB option<br />
KN KA with suppression diode <strong>and</strong> blocking diode<br />
KP KA with suppression diode, blocking diode <strong>and</strong> ground wire<br />
KT KA with light<br />
KU KA with light <strong>and</strong> ground wire<br />
KV KA with suppression diode <strong>and</strong> light<br />
KW KA with suppression diode, light <strong>and</strong> ground wire<br />
KX KA with suppression diode, blocking diode <strong>and</strong> light<br />
KY KA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
PIN #6<br />
PIN #9<br />
MOD. SD09<br />
PIN #1<br />
PIN #5<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 9<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 7 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 2 common wires<br />
PIN #9<br />
PIN #15<br />
MOD. SD15<br />
PIN #1<br />
PIN #8<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 15<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 12 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 3 common wires<br />
PIN #14<br />
PIN #25<br />
MOD. SD25<br />
PIN #1<br />
PIN #13<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 25<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 20 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 5 common wires<br />
Note : Use desired MOD. number after circuit bar part number
O p t i o n s<br />
OPTIONS<br />
Connector termination details<br />
CONNECTOR<br />
SOL 1<br />
SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />
Single solenoid circuit bar<br />
SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />
CONNECTOR<br />
SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />
Double solenoid circuit bar<br />
SD09 SD15 SD25<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
8<br />
COMMON (+)<br />
13<br />
COMMON (+)<br />
21<br />
COMMON (+)<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
9<br />
COMMON (+)<br />
8<br />
SOL. 8<br />
8<br />
SOL. 8<br />
14<br />
COMMON (+)<br />
22<br />
COMMON (+)<br />
9<br />
SOL. 9<br />
9<br />
SOL. 9<br />
10 SOL. 10<br />
10 SOL. 10<br />
11<br />
SOL. 11<br />
11<br />
SOL. 11<br />
12 SOL. 12<br />
12 SOL. 12<br />
15<br />
COMMON (+)<br />
23<br />
COMMON (+)<br />
13<br />
SOL. 13<br />
14 SOL. 14<br />
15<br />
SOL. 15<br />
16 SOL. 16<br />
24<br />
COMMON (+)<br />
17<br />
18 SOL. 18<br />
19<br />
20 SOL. 20<br />
SOL. 17<br />
SOL. 19<br />
25<br />
COMMON (+)
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Circuit bar mounting<br />
non plug-in<br />
with or<br />
without F. C.<br />
non plug-in<br />
with Pr. Reg.<br />
non plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
plug-in<br />
plug-in<br />
with side<br />
Pr. Reg.<br />
plug-in<br />
with s<strong>and</strong>wich<br />
Pr. Reg.<br />
plug-in<br />
with F. C.<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
plug-in<br />
with integral<br />
terminal strip<br />
plug-in with<br />
integral terminal<br />
strip <strong>and</strong><br />
side Pr. Reg.<br />
plug-in with<br />
integral terminal<br />
strip <strong>and</strong><br />
s<strong>and</strong>wich Pr. Reg.<br />
plug-in with<br />
integral terminal<br />
strip with F. C.<br />
plug-in with<br />
integral terminal<br />
strip with<br />
Pr. Reg. <strong>and</strong> F. C.<br />
Manual operator<br />
Armature<br />
Spool push pin<br />
Solenoid<br />
A<br />
EXH.<br />
Spring biased moveable<br />
pole piece<br />
Valve spring<br />
IN<br />
Bonded balanced poppets<br />
B<br />
SERIES FEATURES<br />
• Patented MACSOLENOID ® for fastest possible response times.<br />
• Extremely high cycle rate capability.<br />
• Rated for lubricated or non-lubricated service.<br />
• Various solenoid enclosures <strong>and</strong> plug-in connectors.<br />
• Low wattage DC solenoids - down to 1.8 watts.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
non plug-in<br />
with or<br />
without F. C.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Single operator<br />
A B<br />
A<br />
B<br />
Double operator<br />
(Minimum DC wattage 5,4W)<br />
A<br />
A B<br />
B<br />
EXH<br />
IN<br />
45A-L00-DXXX-XXX<br />
EXH<br />
IN<br />
45A-N00-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
A<br />
J<br />
18” (Flying leads)<br />
Connector<br />
HOW TO ORDER CIRCUIT BAR ** (WITHOUT FLOW CONTROLS)<br />
x<br />
Other Options<br />
1 Non-locking Recessed<br />
KA Square connector<br />
2 Locking Recessed<br />
KD Square connector<br />
with light<br />
x Other Options<br />
BA Flying leads<br />
xx Other Options<br />
EBM45A-xxxx-xx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder<br />
ports<br />
Bottom cylinder<br />
ports<br />
1/8” NPTF<br />
21<br />
EBM45A-001A-XX<br />
EBM45A-002A-XX<br />
# 10-32 UNF<br />
21<br />
EBM45A-001B-XX<br />
EBM45A-002B-XX<br />
HOW TO ORDER CIRCUIT BAR ** (WITH FLOW CONTROLS)<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder<br />
ports<br />
Bottom cylinder<br />
ports<br />
1/8” NPTF<br />
26<br />
EBM45A-015A-XX<br />
EBM45A-016A-XX<br />
# 10-32 UNF<br />
26<br />
EBM45A-015B-XX<br />
EBM45A-016B-XX<br />
1/8” NPTF<br />
40<br />
EBM45A-025A-XX<br />
EBM45A-026A-XX<br />
# 10-32 UNF<br />
40<br />
EBM45A-025B-XX<br />
EBM45A-026B-XX<br />
Number of stations (03=3 stations)<br />
** Other options available Consult factory.<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
VALVE BLANKING PLATE<br />
21,0<br />
"A"<br />
21,0<br />
94,1<br />
25,6<br />
VALVE BLANKING<br />
PLATE<br />
21,0<br />
"A"<br />
21,0<br />
33,0<br />
21,5<br />
~24.5<br />
29,5<br />
B<br />
C L<br />
C L<br />
C L<br />
B B<br />
A A A<br />
7,5<br />
17,0<br />
5,0<br />
11,0<br />
50,5<br />
22,0<br />
IN<br />
EXH<br />
5,1 LOCKING<br />
RECESSED OPERA-<br />
TOR<br />
35,5<br />
B<br />
C L<br />
C L<br />
C L<br />
B B<br />
A A A<br />
5,5<br />
11,0<br />
C<br />
B<br />
65,6<br />
OPTIONAL PRESSURE<br />
SENSING PORT<br />
(#10-32 UNF)<br />
50,5<br />
22,0<br />
18,6<br />
IN<br />
17,0<br />
32,0<br />
40,0<br />
EXH<br />
11,5<br />
~24.5<br />
5,1 LOCKING<br />
RECESSED<br />
OPERATOR<br />
1/8” 2 PORTS<br />
BOTH ENDS<br />
Ø 5,2 MTG.<br />
HOLES<br />
21,0<br />
8,0<br />
7,0<br />
5,0<br />
23,6<br />
B B B<br />
A A A<br />
OPTIONAL<br />
BOTTOM PORTS<br />
C L<br />
C L<br />
C L<br />
5,5<br />
5,5<br />
3,18<br />
13,6<br />
7,14<br />
25,4<br />
FLOW CONTROL<br />
DIMENSIONS<br />
SPACING SIZE<br />
A<br />
STANDARD<br />
21.0<br />
PORT SIZE<br />
B<br />
C<br />
PER JB<br />
26.0<br />
1/8”<br />
20.0<br />
8.0<br />
GAGES<br />
40.0<br />
M5<br />
22.0<br />
6.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
non plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Single operator<br />
A B<br />
A<br />
B<br />
Double operator<br />
(Minimum DC wattage 5,4W)<br />
A<br />
A B<br />
B<br />
Valve w/o gage port<br />
Valve w/ gage port<br />
EXH IN<br />
45A-L00-DXXX-XXX<br />
45A-M00-DXXX-XXX<br />
EXH IN<br />
45A-N00-DXXX-XXX<br />
45A-P00-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
AA 120/60, 110/50<br />
A 18” (Flying leads)<br />
1 Non-locking Recessed<br />
KA Square connector<br />
AB 240/60, 220/50<br />
J Connector<br />
2 Locking Recessed<br />
KD Square connector<br />
with light<br />
AC 24/60, 24/50<br />
x Other Options<br />
x Other Options<br />
BA Flying leads<br />
FB 24VDC (1.8 W)<br />
xx Other Options<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (ORDER REGULATORS SEPARATELY) **<br />
EBM45A-xxxx-xx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder<br />
ports<br />
Bottom cylinder<br />
ports<br />
1/8” NPTF<br />
21 (w/o gage)<br />
EBM45A-003A-XX<br />
EBM45A-004A-XX<br />
# 10-32 UNF<br />
21 (w/o gage)<br />
EBM45A-003B-XX<br />
EBM45A-004B-XX<br />
1/8” NPTF<br />
40 (w/ gage)<br />
EBM45A-023A-XX<br />
EBM45A-024A-XX<br />
# 10-32 UNF<br />
40 (w/ gage)<br />
EBM45A-023B-XX<br />
EBM45A-024B-XX<br />
Number of stations (03=3 stations)<br />
** Other options available Consult factory.<br />
Note : clic for valves <strong>and</strong> regulators mounted to circuit bar at the factory (add - 9 to the model number).<br />
gage not supplied w/circuit bar.<br />
Pressure regulators :<br />
35A-00M (Adjusting knob)<br />
35A-00L (Slotted stem)<br />
35A-00U (Locking stem)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
VALVE BLANKING PLATE<br />
64,5<br />
21,0<br />
"A"<br />
21,0<br />
17,5<br />
33,0<br />
5,1 LOCKING RECESSED<br />
OPERATOR<br />
C L<br />
C L<br />
C L<br />
35,5<br />
B<br />
B<br />
A A A<br />
5,5<br />
B<br />
C<br />
B<br />
56,5<br />
28,0<br />
14,0<br />
IN<br />
EXH<br />
10,25<br />
Ø 5,2.<br />
2 MTG HOLES<br />
11,0<br />
5,0<br />
8,0<br />
35,5<br />
22,0<br />
5,0<br />
1/8” 2 PORTS<br />
BOTH ENDS<br />
14,5<br />
29,5<br />
40,0<br />
91,1<br />
16,0<br />
13,4<br />
SPACING SIZE<br />
STANDARD<br />
PER JB<br />
GAGES<br />
A<br />
21.0<br />
26.0<br />
40.0<br />
11,0<br />
5,5<br />
B<br />
B<br />
A<br />
A<br />
A<br />
C L<br />
C L<br />
21,0<br />
REGULATOR BLANKING<br />
PLATE<br />
15,5<br />
ADJ. LOCKING KNOB<br />
Port size<br />
B<br />
C<br />
B<br />
C L<br />
1/8”<br />
M5<br />
20.0<br />
22.0<br />
8.0<br />
6.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
non plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Single operator<br />
A B<br />
A<br />
B<br />
Double operator<br />
(Minimum DC wattage 5,4W)<br />
A<br />
A B<br />
B<br />
Valve w/o gage port<br />
Valve w/ gage port<br />
EXH IN<br />
45A-L00-DXXX-XXX<br />
45A-M00-DXXX-XXX<br />
EXH IN<br />
45A-N00-DXXX-XXX<br />
45A-P00-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
AA 120/60, 110/50<br />
A 18” (Flying leads)<br />
1 Non-locking Recessed<br />
KA Square connector<br />
AB 240/60, 220/50<br />
J Connector<br />
2 Locking Recessed<br />
KD Square connector<br />
with light<br />
AC 24/60, 24/50<br />
x Other Options<br />
x Other Options<br />
BA Flying leads<br />
FB 24VDC (1.8 W)<br />
xx Other Options<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
EBM45A-xxxx-xx<br />
HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS AND FLOW CONTROLS (ORDER REGULATOR AND FLOW CONTROL SEPARATELY) **<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder<br />
ports<br />
Bottom cylinder<br />
ports<br />
1/8” NPTF<br />
21 (w/o gage)<br />
EBM45A-007A-XX<br />
EBM45A-008A-XX<br />
# 10-32 UNF<br />
21 (w/o gage)<br />
EBM45A-007B-XX<br />
EBM45A-008B-XX<br />
1/8” NPTF<br />
40 (w/ gage)<br />
EBM45A-027A-XX<br />
EBM45A-028A-XX<br />
# 10-32 UNF<br />
40 (w/ gage)<br />
EBM45A-027B-XX<br />
EBM45A-028B-XX<br />
Number of stations (03=3 stations)<br />
** Other options available Consult factory.<br />
Note : clic for valves, regulators <strong>and</strong> flow controls mounted to circuit bar at the factory (add - 9 to the model number).<br />
gage not supplied w/circuit bar<br />
Pressure regulators <strong>and</strong> flow controls:<br />
45A-001 (Slotted stem)<br />
45A-002 (Adjusting knob)<br />
45A-003 (Locking stem)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
21.0<br />
CL<br />
A<br />
CL<br />
CL<br />
CL<br />
66.5<br />
38.0<br />
A<br />
+<br />
+<br />
B<br />
+<br />
+<br />
B A<br />
LC<br />
CL<br />
LC<br />
LC<br />
LC<br />
CL<br />
LC<br />
LC<br />
B<br />
95.6<br />
APPROX.<br />
A<br />
A<br />
A<br />
A<br />
EX<br />
45.0<br />
B<br />
B<br />
B<br />
B<br />
IN<br />
19.5<br />
34.5<br />
A A<br />
B B<br />
5.0 27.0<br />
8.0<br />
LC<br />
CL<br />
LC<br />
LC<br />
15.3<br />
19.0<br />
5.0<br />
A<br />
5.0<br />
15.5<br />
A 26.5<br />
28.5<br />
8.0<br />
B<br />
A<br />
15.5<br />
A<br />
A<br />
B<br />
1/8" - 27 N.P.T.F.<br />
1/8" - 28 B.S.P.PL.<br />
1/8" - 28 B.S.P.TR.<br />
#10-32 UNF<br />
M5 X 0.8<br />
Dim.<br />
SLOTTED<br />
LOCKING STEM<br />
ADJUSTING KNOB<br />
B<br />
6.0<br />
13.4<br />
Dim.<br />
STANDARD<br />
SPACING<br />
SPACING<br />
FOR GAUGES<br />
A<br />
21.0<br />
40.0<br />
26.5<br />
A<br />
Note: Bottom & side cylinder ports not available on the same station<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v plug-in<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />
Single operator<br />
A B<br />
A<br />
B<br />
Double operator<br />
(Minimum DC wattage 5,4W)<br />
A<br />
A B<br />
B<br />
EXH<br />
IN<br />
45A-L00-DXXJ-XFM<br />
EXH<br />
IN<br />
45A-N00-DXXJ-XFM<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR**<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
ECD45A-xxxx-xx-xx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
21<br />
ECD45A-001A-A0-XX<br />
ECD45A-002A-A0-XX<br />
# 10-32 UNF<br />
21<br />
ECD45A-001B-A0-XX<br />
ECD45A-002B-A0-XX<br />
1/8” NPTF<br />
30<br />
ECD45A-031A-C0-XX<br />
ECD45A-032A-C0-XX<br />
# 10-32 UNF<br />
30<br />
ECD45A-031B-C0-XX<br />
ECD45A-032B-C0-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
for multi-pin connector (9, 15 or 25).<br />
O P T I O N S<br />
ECD45A-002A-A0-XX<br />
- clic for double operator valve (replace by 8) (Bottom cylinder ports).<br />
** A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal w/light (120V)<br />
CB = terminal w/light (240V)<br />
CD = terminal w/light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
BLANKING STATION KIT<br />
OPTIONAL PRESSURE<br />
SENSING PORT<br />
21,0<br />
30,0 30,0 21,0<br />
21,0<br />
26,8<br />
73,8<br />
5,1 LOCKING RECESSED<br />
OPERATOR<br />
C L<br />
C L<br />
C L<br />
C L<br />
47,5<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
28,5<br />
68,5<br />
19,8<br />
EX<br />
IN<br />
17,0<br />
40,0<br />
20,0<br />
11,0<br />
37,7<br />
34,5<br />
18,3<br />
6,0<br />
10,0<br />
4,5<br />
Ø 5,2 MOUNTING HOLES<br />
1,45<br />
1/8”<br />
INLET & EXHAUST<br />
PORTS EACH END<br />
13,5<br />
29,0<br />
57,3<br />
78,0<br />
84,8<br />
1” NPSM<br />
CONDUIT<br />
EACH END<br />
5,5<br />
5,5<br />
1,8<br />
4,5<br />
8,0<br />
7,8<br />
68,5<br />
40,0<br />
105,58<br />
17,0 19,0<br />
4,5<br />
29,0<br />
57,3<br />
13,5<br />
37,0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
plug-in<br />
with side<br />
Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR "PLUG-IN" CIRCUIT BAR<br />
Single operator<br />
A<br />
A<br />
B<br />
B<br />
EXH IN<br />
45A-L00-DXXJ-XFM<br />
45A-M00-DXXJ-XFM<br />
Valve w/o gage port<br />
Valve w/ gage port<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY) **<br />
ECD45A-xxxx-xx-xx<br />
Port size<br />
1/8” NPTF<br />
# 10-32 UNF<br />
1/8” NPTF<br />
# 10-32 UNF<br />
1/8” NPTF<br />
# 10-32 UNF<br />
Spacing<br />
mm<br />
21<br />
21<br />
30<br />
30<br />
40<br />
40<br />
Bottom cylinder ports<br />
ECD45A-004A-A0-XX<br />
ECD45A-004B-A0-XX<br />
ECD45A-034A-C0-XX<br />
ECD45A-034B-C0-XX<br />
ECD45A-024A-A0-XX<br />
ECD45A-024B-A0-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves <strong>and</strong> regulators mounted to circuit bar at the factory (add - 9 to<br />
the model number).<br />
for multi-pin connector (9, 15 or 25).<br />
minimum spacing for terminal strips is 30 mm.<br />
use 40 mm spacing for gages.<br />
** Pressure Regulators :<br />
35A-00M (Adjusting knob)<br />
35A-00L (Slotted stem)<br />
35A-00U (Locking stem)<br />
Consult “Precautions”before use, installation or service of MAC Valves.<br />
** A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal w/light (120V)<br />
CB = terminal w/light (240V)<br />
CD = terminal w/light (24V)
B<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
BLANKING STATION KIT<br />
21,0<br />
30,0 30,0 21,0<br />
21,0<br />
26,8<br />
OPTIONAL PRESSURE<br />
SENSING PORT<br />
73,8<br />
0,2 LOCKING RECESSED<br />
OPERATOR<br />
C L<br />
C L<br />
C L<br />
C L<br />
47,5<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
28,5<br />
68,5<br />
19,8<br />
EX<br />
IN<br />
17,0<br />
40,0<br />
20,0<br />
11,0<br />
6,0<br />
10,0<br />
4,5<br />
Ø 5,2 MOUNTING HOLES<br />
1,45<br />
1/8” INLET &<br />
EXHAUST PORTS<br />
EACH END<br />
13,5<br />
29,0<br />
57,3<br />
78,0<br />
84,8<br />
1” NPSM<br />
CONDUIT<br />
EACH END<br />
15,5<br />
4,5<br />
A<br />
5,5<br />
5,5<br />
LOCK<br />
ADJ. LOCKING KNOB<br />
60,5 20,7<br />
34,5<br />
37,0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
plug-in<br />
with s<strong>and</strong>wich<br />
Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />
Single operator<br />
A<br />
A<br />
B<br />
B<br />
EXH IN<br />
45A-L00-DXXJ-XFM<br />
45A-M00-DXXJ-XFM<br />
Valve w/o gage port<br />
Valve w/ gage port<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
ECD45A-xxxx-xx-xx<br />
HOW TO ORDER "PLUG-IN" CIRCUIT BAR WITH SANDWICH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY) **<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
21<br />
ECD45A-001A-A0-XX<br />
ECD45A-002A-A0-XX<br />
# 10-32 UNF<br />
21<br />
ECD45A-001B-A0-XX<br />
ECD45A-002B-A0-XX<br />
1/8” NPTF<br />
30<br />
ECD45A-031A-C0-XX<br />
ECD45A-032A-C0-XX<br />
# 10-32 UNF<br />
30<br />
ECD45A-031B-C0-XX<br />
ECD45A-032B-C0-XX<br />
1/8” NPTF<br />
40<br />
ECD45A-021A-A0-XX<br />
ECD45A-022A-A0-XX<br />
# 10-32 UNF<br />
40<br />
ECD45A-021B-A0-XX<br />
ECD45A-022B-A0-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves <strong>and</strong> regulators mounted to circuit bar at the factory, add - 9 to<br />
the model number.<br />
for multi-pin connector (9, 15 or 25).<br />
minimum spacing for terminal strips is 30 mm.<br />
use 40 mm spacing for gages.<br />
** Pressure Regulators :<br />
PR45A-AA0A (Adjusting knob)<br />
PR45A-AB0A (Slotted stem)<br />
PR45A-AC0A (Locking stem)<br />
Consult “Precautions”before use, installation or service of MAC Valves.<br />
** A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal w/light (120V)<br />
CB = terminal w/light (240V)<br />
CD = terminal w/light (24V)
L<br />
OCK<br />
L OCK<br />
L OCK<br />
L OCK<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
26.0<br />
15.0<br />
A<br />
A<br />
Dim.<br />
A<br />
Dim.<br />
B<br />
28.5<br />
40.0<br />
10.0<br />
B A B A B A B A<br />
1/8" - 27 N.P.T.F.<br />
1/8" - 28 B.S.P.PL.<br />
1/8" - 28 B.S.P.TR.<br />
#10-32<br />
M5 0.8<br />
STANDARD<br />
SPACING<br />
OPTIONAL<br />
SPACING<br />
SPACING<br />
FOR GAUGES<br />
21.0<br />
30.0<br />
40.0<br />
SLOTTED<br />
LOCKING STEM<br />
ADJUSTING KNOB<br />
Note: Bottom & side cylinder ports not available on the same station<br />
6.0<br />
13.4<br />
21.0<br />
A<br />
94.0<br />
APPROX.<br />
B<br />
B<br />
B<br />
B<br />
B<br />
EX<br />
123.1<br />
APPROX.<br />
37.7<br />
26.5<br />
15.5<br />
4.5<br />
TYP.<br />
20.8<br />
B<br />
A<br />
B<br />
78.0<br />
A<br />
A<br />
A<br />
A<br />
IN<br />
49.0<br />
64.5<br />
34.5 A<br />
A<br />
20.7<br />
96.0<br />
17.0<br />
19.8<br />
20.0<br />
A<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
plug-in<br />
with F. C.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />
Port size<br />
(see base)<br />
Single operator<br />
A<br />
A<br />
B<br />
B<br />
Valve less base<br />
EXH<br />
IN<br />
45A-L00-DXXJ-XFM<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER "PLUG-IN" CIRCUIT BAR WITH FLOW CONTROLS **<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
ECD45A-xxxx-xx-xx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
21<br />
--------<br />
ECD45A-006A-A0-XX<br />
# 10-32 UNF<br />
21<br />
--------<br />
ECD45A-006B-A0-XX<br />
1/8” NPTF<br />
30<br />
ECD45A-035A-A0-XX<br />
--------<br />
# 10-32 UNF<br />
30<br />
ECD45A-035B-A0-XX<br />
--------<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
for multi-pin connector (9, 15 or 25).<br />
minimum spacing for terminal strips is 30 mm.<br />
** A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal w/light (120V)<br />
CB = terminal w/light (240V)<br />
CD = terminal w/light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
L<br />
68.6<br />
40.0<br />
19.8<br />
17.0<br />
13.2<br />
Max.<br />
78.0<br />
84.3<br />
89.2 ( Optional )<br />
29.0<br />
13.5<br />
EX IN<br />
1/8 (IN + EX)<br />
43.0<br />
40.0<br />
14.5<br />
13.0<br />
8.0<br />
A<br />
B A B A B A B<br />
10.3<br />
DIA. 5.2 (2X)<br />
37.0<br />
37.0<br />
26.0<br />
21.0<br />
51.0<br />
4.5<br />
Number of<br />
stations<br />
2<br />
3<br />
4<br />
5<br />
6<br />
4.5<br />
7<br />
8<br />
9<br />
10<br />
DIM. L<br />
77.0<br />
107.0<br />
137.0<br />
167.0<br />
197.0<br />
227.0<br />
257.0<br />
287.0<br />
317.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
plug-in<br />
with Pr. Reg.<br />
<strong>and</strong> F. C.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />
Port size<br />
(see base)<br />
Single operator<br />
A<br />
A<br />
B<br />
B<br />
Valve less base (w/o gage port)<br />
Valve less base (w/ gage port)<br />
EXH IN<br />
45A-L00-DXXJ-XFM<br />
45A-M00-DXXJ-XFM<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
ECD45A-xxxx-xx-xx<br />
HOW TO ORDER "PLUG-IN" CIRCUIT BAR WITH REGULATORS AND FLOW CONTROLS (TO BE ORDERED SEPARATELY) **<br />
Port size<br />
1/8” NPTF<br />
# 10-32 UNF<br />
1/8” NPTF<br />
# 10-32 UNF<br />
Spacing<br />
mm<br />
21<br />
21<br />
30<br />
30<br />
Bottom cylinder ports<br />
ECD45A-007A-A0-XX<br />
ECD45A-007B-A0-XX<br />
ECD45A-037A-C0-XX<br />
ECD45A-037B-C0-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves <strong>and</strong> regulators mounted to circuit bar at the factory<br />
(add - 9 to the model number).<br />
for multi-pin connector (9, 15 or 25).<br />
minimum spacing for terminal strips is 30 mm.<br />
Pressure regulators <strong>and</strong> flow controls:<br />
45A-001 (Slotted stem)<br />
45A-002 (Adjusting knob)<br />
45A-003 (Locking stem)<br />
** A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
** C0 = terminal strip<br />
CA = terminal w/light (120V)<br />
CB = terminal w/light (240V)<br />
CD = terminal w/light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
L<br />
68.6<br />
40.0<br />
19.8<br />
17.0<br />
10.0<br />
21.0<br />
78.0<br />
84.3<br />
89.2 ( Optional )<br />
29.0<br />
13.5<br />
IN<br />
EX<br />
1/8 (IN + EX)<br />
7.0<br />
37.0<br />
A<br />
A<br />
A<br />
A<br />
B B B B<br />
DIA. 5.2 (2<br />
20.7<br />
34.5<br />
37.0<br />
148.2<br />
4.5<br />
4.5<br />
20.5<br />
17.3<br />
26.0<br />
21.0<br />
42.0<br />
Number of<br />
stations<br />
DIM. L<br />
2<br />
68.0<br />
3<br />
89.0<br />
4<br />
110.0<br />
5<br />
131.0<br />
6<br />
152.0<br />
7<br />
173.0<br />
8<br />
194.0<br />
9<br />
215.0<br />
10<br />
236.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting s<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
plug-in<br />
with integral<br />
terminal strip<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-LOO-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />
Single operator<br />
A<br />
A<br />
B<br />
B<br />
EXH<br />
IN<br />
45A-L00-DXXJ-XFM<br />
Valve less base<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR**<br />
ECE45A-011A-CD-02<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
26<br />
ECE45A-011A-C0-XX<br />
ECE45A-012A-C0-XX<br />
# 10-32 UNF<br />
26<br />
ECE45A-011B-C0-XX<br />
ECE45A-012B-C0-XX<br />
Number of stations (03=3 stations)<br />
End plate kit required : M-45017<br />
Note : clic for valves mounted on circuit bar at the factory (add - 9 to the<br />
model number).<br />
2<br />
** C0 = terminal strip<br />
CA = terminal strip w/light (120V)<br />
CB = terminal strip w/light (240V)<br />
CD = terminal strip w/light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
49.5<br />
38.5<br />
A<br />
A<br />
10.0<br />
28.5<br />
40.0<br />
LC<br />
C L C L C L<br />
1/4" - 18 N.P.T.F.<br />
TYP. (2) EACH END<br />
68.4<br />
C L<br />
C L<br />
C L<br />
C L<br />
IN<br />
EX<br />
B<br />
B<br />
B<br />
B<br />
EX<br />
IN<br />
89.4<br />
100.4<br />
A<br />
A<br />
A<br />
A<br />
G<br />
33.9<br />
71.4<br />
79.7<br />
65.9<br />
58.4<br />
16.0<br />
44.5<br />
26.0<br />
1" - 11 1/2 N.P.S.M<br />
19.9<br />
28.9<br />
10.9<br />
158.0<br />
A 39.0<br />
A 50.0<br />
4.5<br />
TYP.<br />
Note: Bottom & side cylinder ports not available on the same station<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
integral terminal<br />
strip <strong>and</strong><br />
plug-in with<br />
side Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />
Single operator<br />
A<br />
A<br />
B<br />
B<br />
EXH IN<br />
45A-L00-DXXJ-XFM<br />
45A-M00-DXXJ-XFM<br />
Valve less base w/o gage port<br />
Valve less base w/ gage port<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY) **<br />
ECE45A-xxxx-xx-xx<br />
Port size<br />
1/8” NPTF<br />
# 10-32 UNF<br />
1/8” NPTF<br />
# 10-32 UNF<br />
Spacing<br />
mm<br />
26<br />
26<br />
40<br />
40<br />
Bottom cylinder ports<br />
ECE45A-014A-C0-XX<br />
ECE45A-014B-C0-XX<br />
ECE45A-024A-C0-XX<br />
ECE45A-024B-C0-XX<br />
Number of stations (03=3 stations)<br />
End plate kit required : M-45017<br />
Note : clic for valves <strong>and</strong> regulators mounted to circuit<br />
bar at the factory (add - 9 to the model number).<br />
Use 40 mm spacing for valves w/ gage port.<br />
** Pressure Regulators :<br />
35A-00M (Adjusting knob)<br />
35A-00L (Slotted stem)<br />
35A-00U (Locking stem)<br />
** C0 = terminal strip<br />
CA = terminal strip w/light (120V)<br />
CB = terminal strip w/light (240V)<br />
CD = terminal strip w/light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
40.0<br />
LC<br />
LC<br />
LC<br />
68.4<br />
1/4" - 18 N.P.T.F.<br />
TYP. (2) EACH END<br />
B<br />
154.5<br />
89.4<br />
100.4<br />
71.4<br />
33.9<br />
58.4<br />
16.0<br />
44.5<br />
A<br />
C L C L C L C L C L C L C L C L<br />
4.5<br />
B<br />
B<br />
B<br />
B<br />
EX<br />
IN<br />
EX<br />
A<br />
A<br />
A<br />
A<br />
IN<br />
C L<br />
79.7<br />
65.9<br />
G<br />
1" - 11 1/2 N.P.S.M<br />
19.9<br />
28.9<br />
10.9<br />
158.0<br />
A<br />
A<br />
39.0<br />
50.0<br />
Dim.<br />
B<br />
Dim.<br />
A<br />
SLOTTED<br />
LOCKING STEM<br />
ADJUSTING KNOB<br />
6.0<br />
13.4<br />
STANDARD<br />
SPACING<br />
SPACING<br />
FOR GAUGES<br />
26.0<br />
40.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
integral terminal<br />
strip <strong>and</strong><br />
plug-in with<br />
s<strong>and</strong>wich Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />
Single operator<br />
A<br />
A<br />
B<br />
B<br />
EXH IN<br />
45A-L00-DXXJ-XFM<br />
45A-M00-DXXJ-XFM<br />
Valve w/o gage port<br />
Valve w/ gage port<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR WITH SANDWICH REGULATORS (TO BE ORDERED SEPARATELY) **<br />
ECE45A-xxxx-xx-xx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
26<br />
ECE45A-011A-C0-XX<br />
ECE45A-012A-C0-XX<br />
# 10-32 UNF<br />
26<br />
ECE45A-011B-C0-XX<br />
ECE45A-012B-C0-XX<br />
1/8” NPTF<br />
40<br />
ECE45A-021A-C0-XX<br />
ECE45A-022A-C0-XX<br />
# 10-32 UNF<br />
40<br />
ECE45A-021B-C0-XX<br />
ECE45A-022B-C0-XX<br />
Number of stations (03=3 stations)<br />
End plate kit required : M-45017<br />
Note : clic for valves <strong>and</strong> regulators mounted to circuit<br />
bar at the factory (add - 9 to the model number).<br />
Use 40 mm spacing for valves w/ gage port.<br />
** Pressure Regulators :<br />
PR45A-AA0A (Adjusting knob)<br />
PR45A-AB0A (Slotted stem)<br />
PR45A-AC0A (Locking stem)<br />
** C0 = terminal strip<br />
CA = terminal strip w/light (120V)<br />
CB = terminal strip w/light (240V)<br />
CD = terminal strip w/light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
L OCK<br />
LOCK<br />
LOCK<br />
L<br />
OCK<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
10.0<br />
49.5<br />
38.5<br />
A<br />
A<br />
Dim.<br />
A<br />
Dim.<br />
B<br />
28.5<br />
40.0<br />
1/8" - 27 N.P.T.F.<br />
1/8" - 28 B.S.P.PL.<br />
1/8" - 28 B.S.P.TR.<br />
#10-32<br />
M5 X 0.8<br />
STANDARD<br />
SPACING<br />
SPACING FOR<br />
GAUGES<br />
26.0<br />
40.0<br />
SLOTTED<br />
LOCKING STEM<br />
ADJUSTING KNOB<br />
Note: Bottom & side cylinder ports not available on the same station<br />
6.0<br />
13.4<br />
LC<br />
LC<br />
LC<br />
LC<br />
93.8<br />
1/4" - 18 N.P.T.F.<br />
TYP. (2) EACH END<br />
LC<br />
LC<br />
LC<br />
LC<br />
B<br />
144.5<br />
APPROX.<br />
IN<br />
EX<br />
B<br />
B<br />
B<br />
B<br />
EX<br />
IN<br />
89.4<br />
A<br />
A<br />
A<br />
A<br />
G<br />
33.9<br />
71.4<br />
79.7<br />
65.9<br />
58.4<br />
16.0<br />
44.5<br />
A<br />
1" - 11 1/2 N.P.S.M<br />
19.9<br />
28.9<br />
10.9<br />
A<br />
A<br />
39.0<br />
50.0<br />
4.5<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
plug-in with<br />
integral terminal<br />
strip with F. C.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />
Single operator<br />
A<br />
A<br />
B<br />
B<br />
EXH<br />
IN<br />
45A-L00-DXXJ-XFM<br />
Valve less base<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR WITH FLOW CONTROLS **<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
ECE45A-xxxx-xx-xx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
26<br />
--------<br />
ECE45A-016A-C0-XX<br />
# 10-32 UNF<br />
26<br />
--------<br />
ECE45A-016B-C0-XX<br />
1/8” NPTF<br />
30<br />
ECE45A-035A-C0-XX<br />
--------<br />
# 10-32 UNF<br />
30<br />
ECE45A-035B-C0-XX<br />
--------<br />
Number of stations (03=3 stations)<br />
End plate kit required : M-45017<br />
Note : clic for valves <strong>and</strong> regulators mounted to circuit<br />
bar at the factory (add - 9 to the model number).<br />
** C0 = terminal strip<br />
CA = terminal strip w/light (120V)<br />
CB = terminal strip w/light (240V)<br />
CD = terminal strip w/light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
27.5<br />
13.0<br />
8.0 10.3<br />
40.0<br />
B A<br />
B A<br />
B A<br />
B A<br />
+<br />
LC<br />
+<br />
+<br />
+ + + + +<br />
C L C L C L<br />
1/8" - 27 N.P.T.F.<br />
1/8" - 28 B.S.P.PL.<br />
1/8" - 28 B.S.P.TR.<br />
#10-32<br />
M5 X 0.8<br />
1/4" - 18 N.P.T.F.<br />
TYP. (2) EACH END<br />
68.4<br />
B<br />
B<br />
B<br />
B<br />
IN<br />
EX<br />
EX<br />
111.9<br />
IN<br />
89.4<br />
A<br />
A<br />
A<br />
A<br />
71.4<br />
65.9<br />
79.7<br />
G<br />
33.9<br />
58.4<br />
16.0<br />
44.5<br />
A<br />
1" - 11 1/2 N.P.S.M 10.9<br />
158.0<br />
19.9<br />
28.9<br />
A<br />
A<br />
39.0<br />
50.0<br />
4.5<br />
Dim.<br />
STANDARD<br />
SPACING<br />
OPTIONAL<br />
SPACING<br />
A<br />
26.0<br />
30.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.<br />
Note: Bottom & side cylinder ports not available on the same station
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 45<br />
Function Port size Flow (Max) Circuit bar mounting<br />
4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />
integral terminal<br />
strip with<br />
plug-in with<br />
Pr. Reg. <strong>and</strong> F. C.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Burn-out proof solenoid on AC service.<br />
Reset<br />
HOW TO ORDER<br />
45A-xxx-DxxJ-xFM<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />
Single operator<br />
A<br />
A<br />
B<br />
B<br />
EXH IN<br />
45A-L00-DXXJ-XFM<br />
45A-M00-DXXJ-XFM<br />
Valve less base<br />
Valve less base w/ gage port<br />
SOLENOID OPERATOR ➤<br />
D XX J- X FM *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
AA 120/60, 110/50<br />
AB 240/60, 220/50<br />
AC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
1 Non-locking Recessed<br />
2 Locking Recessed<br />
x Other Options<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR WITH PRESSURE AND FLOW CONTROLS (TO BE ORDERED SEPARATELY) **<br />
ECE45A-xxxx-xx-xx<br />
Port size<br />
1/8” NPTF<br />
# 10-32 UNF<br />
1/8” NPTF<br />
# 10-32 UNF<br />
Spacing<br />
mm<br />
26<br />
26<br />
40<br />
40<br />
Bottom cylinder ports<br />
ECE45A-017A-C0-XX<br />
ECE45A-017B-C0-XX<br />
ECE45A-027A-C0-XX<br />
ECE45A-027B-C0-XX<br />
Number of stations (03=3 stations)<br />
End plate kit required : M-45017<br />
Note : clic for valves <strong>and</strong> regulators mounted to circuit<br />
bar at the factory (add - 9 to the model number).<br />
Use 40 mm spacing for valves w/ gage port.<br />
** Pressure Regulators :<br />
45A-001 (Slotted stem)<br />
45A-002 (Adjusting knob)<br />
45A-003 (Locking stem)<br />
** C0 = terminal strip<br />
CA = terminal strip w/light (120V)<br />
CB = terminal strip w/light (240V)<br />
CD = terminal strip w/light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
L O<br />
CK<br />
L<br />
OCK<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 45<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
2 mm<br />
1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
Nema 4<br />
120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />
DC VOLTS = 1.8 W to 12.7 W<br />
24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />
120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />
Spare parts :<br />
Options :<br />
• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />
• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />
• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />
• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
EX<br />
B<br />
B<br />
B<br />
B<br />
B<br />
A<br />
B A<br />
B A<br />
B A<br />
L O<br />
CK<br />
L O<br />
CK<br />
Dim.<br />
B<br />
Dim.<br />
A<br />
40.0<br />
SLOTTED<br />
LOCKING STEM<br />
ADJUSTING KNOB<br />
6.0<br />
13.4<br />
STANDARD<br />
SPACING<br />
SPACING<br />
FOR GAUGES<br />
26.0<br />
40.0<br />
+<br />
+<br />
+<br />
+<br />
+<br />
+<br />
+<br />
+<br />
LC<br />
C L C L C L<br />
LC<br />
LC<br />
LC<br />
LC<br />
1/4" - 18 N.P.T.F.<br />
TYP. (2) EACH END<br />
68.4<br />
B<br />
LC<br />
LC<br />
LC<br />
LC<br />
154.5<br />
IN<br />
EX<br />
IN<br />
89.4<br />
A<br />
A<br />
A<br />
A<br />
71.4<br />
65.9<br />
79.7<br />
G<br />
33.9<br />
58.4<br />
16.0<br />
44.5<br />
A<br />
1" - 11 1/2 N.P.S.M<br />
19.9<br />
28.9<br />
10.9<br />
158.0<br />
A<br />
A<br />
39.0<br />
50.0<br />
4.5<br />
TYP.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Section 2 Options<br />
Consult “Precautions” before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Codification table for voltages / Wire length / Manual operators / Electrical connections<br />
VALVE CODE ➤<br />
- D XX X - X XX<br />
1 2 3 4<br />
OPTIONS AVAILABLE FOR<br />
- Solenoid valves 35 & 45 Series<br />
Consult “Precautions”before use, installation or service of MAC Valves.
OPTIONS<br />
Back<br />
1. VOLTAGE<br />
- D XX X - X XX VOLTAGE<br />
AD 24/60<br />
AE 200/60<br />
AF 240/50<br />
AG 100/50, 100/60, 110/60<br />
DB 12 VDC (5.4 W)<br />
DC 12 VDC (7.5 W)<br />
DD 24 VDC (7.3 W)<br />
DE<br />
12 VDC (12.7 W) CLSF<br />
DK 110 VDC (5.8 W)<br />
DL 64 VDC (6.0 W)<br />
DM 36 VDC (5.8 W)<br />
DN 6 VDC (6.0 W)<br />
DP 48 VDC (5.8 W)<br />
DU 24 VDC (6.0 W)<br />
EA 12 VDC (6.0 W)<br />
FA 12 VDC (1.8 W)<br />
FE 12 VDC (2.4 W)<br />
FF 24 VDC (2.4 W)<br />
2. WIRE LENGTH<br />
- D XX X - X XX WIRE LENGTH<br />
B 24”<br />
C 36”<br />
D 48”<br />
E 72”<br />
F 96”<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Back<br />
3. MANUAL OPERATOR<br />
- D XX X - X XX MANUAL OPERATOR<br />
0 No operator<br />
1 Non-locking recessed<br />
2 Locking recessed<br />
3 Non-locking extended<br />
4 Locking extended<br />
4. ELECTRICAL CONNECTION<br />
- D XX X - X XX ELECTRICAL CONNECTION<br />
BA Flying leads<br />
BK BA with protection diode<br />
BL BA with protection varistor<br />
CA 1/2" NPS conduit<br />
*FN Plug-in with diode<br />
*FP Plug-in with M.O.V.<br />
JB Rectangular connector<br />
JD Rectangular connector with light<br />
JM Rectangular connector, male only<br />
KA Square connector<br />
KB Square connector with protection diode<br />
KC Square connector with protection varistor<br />
KD Square connector with light<br />
KE Square connector with light <strong>and</strong> protection diode<br />
KF Square connector with light <strong>and</strong> protection varistor<br />
KJ Square connector (male only)<br />
KK Square connector with protection diode (male only)<br />
KL Square connector with protection varistor (male only)<br />
TA Dual tabs<br />
TB TA with protection diode<br />
TD TA with light<br />
TE TA with light <strong>and</strong> protection diode<br />
TJ Dual tabs (male only)<br />
TK TJ with protection diode<br />
TM TJ with light<br />
TN TJ with light <strong>and</strong> protection diode<br />
* For use with the ECD <strong>and</strong> ECE style circuit bars.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
PIN #6<br />
PIN #9<br />
MOD. SD09<br />
PIN #1<br />
PIN #5<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 9<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 7 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 2 common wires<br />
PIN #9<br />
PIN #15<br />
MOD. SD15<br />
PIN #1<br />
PIN #8<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 15<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 12 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 3 common wires<br />
PIN #14<br />
PIN #25<br />
MOD. SD25<br />
PIN #1<br />
PIN #13<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 25<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 20 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 5 common wires<br />
Note : Use desired MOD. number after circuit bar part number
O p t i o n s<br />
OPTIONS<br />
Connector termination details<br />
CONNECTOR<br />
SOL 1<br />
SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />
Single solenoid circuit bar<br />
SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />
CONNECTOR<br />
SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />
Double solenoid circuit bar<br />
SD09 SD15 SD25<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
8<br />
COMMON (+)<br />
13<br />
COMMON (+)<br />
21<br />
COMMON (+)<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
9<br />
COMMON (+)<br />
8<br />
SOL. 8<br />
8<br />
SOL. 8<br />
14<br />
COMMON (+)<br />
22<br />
COMMON (+)<br />
9<br />
SOL. 9<br />
9<br />
SOL. 9<br />
10 SOL. 10<br />
10 SOL. 10<br />
11<br />
SOL. 11<br />
11<br />
SOL. 11<br />
12 SOL. 12<br />
12 SOL. 12<br />
15<br />
COMMON (+)<br />
23<br />
COMMON (+)<br />
13<br />
SOL. 13<br />
14 SOL. 14<br />
15<br />
SOL. 15<br />
16 SOL. 16<br />
24<br />
COMMON (+)<br />
17<br />
18 SOL. 18<br />
19<br />
20 SOL. 20<br />
SOL. 17<br />
SOL. 19<br />
25<br />
COMMON (+)
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Circuit bar mounting<br />
non plug-in<br />
cyl. ports in<br />
valve with<br />
opt. F. C.<br />
non plug-in<br />
cyl. ports in<br />
base with<br />
opt. F. C.<br />
add-on style<br />
non plug-in cyl.<br />
ports in valve<br />
with opt. F. C.<br />
add-on style<br />
non plug-in cyl.<br />
ports in base<br />
with opt. F. C.<br />
non plug-in<br />
cyl. ports in<br />
valve with<br />
opt. Pr. Reg.<br />
non plug-in<br />
cyl. ports<br />
in base<br />
non plug-in<br />
cyl. ports in<br />
base with<br />
Pr. Reg.<br />
add-on style<br />
non plug-in<br />
cyl. ports in<br />
base<br />
add-on style<br />
non plug-in cyl.<br />
ports in base<br />
with Pr. Reg.<br />
plug-in<br />
plug-in<br />
with Pr. Reg.<br />
add-on style<br />
plug-in<br />
add-on style<br />
plug-in<br />
with Pr. Reg.<br />
plug-in<br />
add-a-unit<br />
stations<br />
plug-in<br />
add-a-unit<br />
stations<br />
with Pr. Reg.<br />
Manual operator<br />
Armature<br />
Coil<br />
Push pin<br />
Pole piece<br />
“D” seal<br />
Conical seat<br />
Poppet<br />
4<br />
2<br />
5<br />
1<br />
Valve return spring<br />
3<br />
SERIES FEATURES<br />
• Short stroke solenoid produces high energization shifting force.<br />
• High force return spring due to high force solenoid maximizes<br />
both energization <strong>and</strong> de-energization shifting forces.<br />
• Built-in wear compensation - valve stroke is shorter than solenoid stroke.<br />
• Four (4) bonded balanced poppets on a one-piece valve stem.<br />
• End poppets seal first on conical seats <strong>and</strong> cushion inlet poppet, eliminating cutting.<br />
• Exhaust seals are not under inlet pressure thus reducing friction.<br />
• Short stroking balanced poppet allows for direct solenoid operation with high shifting forces,<br />
minimized friction, fast response <strong>and</strong> high flow in a small package.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting Profile<br />
non plug-in<br />
5/2 3/8” 0.5C v<br />
cyl. ports in<br />
valve with<br />
29 mm<br />
opt. F. C.<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Valve port size<br />
Valve less base<br />
2<br />
4<br />
12<br />
14<br />
1/8” NPTF<br />
1/4” NPTF<br />
3 1 5<br />
47A-MG0-HXXX-XXX<br />
47A-MH0-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
A 18”<br />
1 Non-locking<br />
BA<br />
Flying leads<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
BC<br />
Flying leads with light<br />
DC 24VDC (1.8 W)<br />
x<br />
Other Options<br />
MA<br />
MC<br />
Plug-in wire assy<br />
Plug-in wire assy<br />
DD 24VDC (1.0 W)<br />
with light<br />
AA<br />
120VAC (must use with<br />
HA<br />
Plug-in connector with<br />
rectified connector)<br />
rectifier <strong>and</strong> light<br />
xx<br />
Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
COMMON INLET & EXHAUST<br />
3/8” NPTF<br />
Without flow controls<br />
(20 mm)<br />
EBM47A-01CAK-XX<br />
EBM47A-xxxxx-xx<br />
With flow controls<br />
(20 mm)<br />
EBM47A-01DAK-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
4<br />
4<br />
4<br />
4<br />
2<br />
2<br />
2<br />
2<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47002.<br />
• Flow control kit (x2) : N-37001.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
78.1<br />
25.0 20.0<br />
7.0<br />
96.0<br />
TYP.<br />
14.5<br />
132.4<br />
31.1<br />
50.6<br />
3 1 5<br />
12<br />
12<br />
12<br />
12<br />
3<br />
1<br />
5<br />
82.0<br />
26.5<br />
26.5<br />
27.8<br />
26.5<br />
14<br />
14<br />
14<br />
14<br />
29.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
5/2 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
non plug-in<br />
cyl. ports in<br />
base with<br />
opt. F. C.<br />
29 mm<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
Valve<br />
(see base)<br />
2<br />
4<br />
12<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
A 18”<br />
1 Non-locking<br />
BA<br />
Flying leads<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
BC<br />
Flying leads with light<br />
DC 24VDC (1.8 W)<br />
x<br />
Other Options<br />
MA<br />
MC<br />
Plug-in wire assy<br />
Plug-in wire assy<br />
DD 24VDC (1.0 W)<br />
with light<br />
AA<br />
120VAC (must use with<br />
HA<br />
Plug-in connector with<br />
rectified connector)<br />
rectifier <strong>and</strong> light<br />
xx<br />
Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
1/8” NPTF<br />
1/4” NPTF<br />
6 mm tube receptacle<br />
Bottom cylinder ports<br />
(18 mm)<br />
EBM47A-00AAA-XX<br />
EBM47A-00AAB-XX<br />
EBM47A-00AAG-XX<br />
EBM47A-xxxxx-xx<br />
Bottom cylinder ports with flow controls<br />
(18 mm)<br />
EBM47A-00BAA-XX<br />
EBM47A-00BAB-XX<br />
EBM47A-00BAG-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• Flow control kit (x2) : N-37001.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
104.0<br />
14.5<br />
78.1<br />
7.0<br />
90.0<br />
25.0 18.0<br />
132.4<br />
3 1 5<br />
12<br />
14<br />
12<br />
14<br />
12<br />
14<br />
12<br />
14<br />
3<br />
1<br />
5<br />
82.0<br />
26.5<br />
26.5<br />
27.8<br />
26.5<br />
2<br />
4 4<br />
2<br />
22.0<br />
30.0<br />
29.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting Profile<br />
add-on style<br />
5/2 3/8” 0.5C v<br />
non plug-in cyl.<br />
ports in valve<br />
35 mm<br />
with opt. F. C.<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Valve port size<br />
Valve<br />
2<br />
4<br />
12<br />
14<br />
1/8” NPTF<br />
1/4” NPTF<br />
3 1 5<br />
47A-MG0-HXXX-XXX<br />
47A-MH0-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
A 18”<br />
1 Non-locking<br />
BA<br />
Flying leads<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
BC<br />
Flying leads with light<br />
DC 24VDC (1.8 W)<br />
x<br />
Other Options<br />
MA<br />
MC<br />
Plug-in wire assy<br />
Plug-in wire assy<br />
DD 24VDC (1.0 W)<br />
with light<br />
AA<br />
120VAC (must use with<br />
HA<br />
Plug-in connector with<br />
rectified connector)<br />
rectifier <strong>and</strong> light<br />
xx<br />
Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
EBM47A-xxxxx-xx<br />
Port size<br />
COMMON INLET & EXHAUST<br />
3/8” NPTF<br />
Without flow controls<br />
(20 mm)<br />
EBM47A-01GBK-XX<br />
With flow controls<br />
(20 mm)<br />
EBM47A-01HBK-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
add-a-unit stations may be added to above bars.<br />
Maximum length for add-a-unit is 4 stations.<br />
O P T I O N S<br />
EBM47A-01GBK-XX<br />
- clic replace with “C” for add-a-unit.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
4<br />
4<br />
4<br />
4<br />
2<br />
2<br />
2<br />
2<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47002.<br />
• Flow control kit (x2) : N-37001. End plate kit : M-47004-01.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
57.0 XX<br />
25.0 20.0<br />
3/8" - 18 N.P.T.F.<br />
3 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.S.P.TR<br />
3 HOLES<br />
BOTH ENDS<br />
7.0<br />
7.0<br />
12.0<br />
6.7<br />
TYP.<br />
BOTH<br />
ENDS<br />
3/8" - 19 B.P.S.PL<br />
3 HOLES<br />
BOTH ENDS<br />
82.0<br />
27.8<br />
TYP.<br />
26.5<br />
TYP.<br />
5 1<br />
3<br />
12<br />
14<br />
12<br />
14<br />
12<br />
14<br />
12<br />
14<br />
3 1 5<br />
132.5<br />
30.9<br />
TYP.<br />
19.5<br />
TYP.<br />
14.5<br />
41.0<br />
67.5<br />
5.20 DIA. THRU.<br />
(4) MTG. HOLES<br />
16.0<br />
19.0<br />
23.5<br />
84.6<br />
35.0<br />
Number of<br />
stations<br />
XX<br />
1<br />
24.0<br />
2<br />
44.0<br />
3 4<br />
64.0 84.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
5/2 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
add-on style<br />
non plug-in cyl.<br />
ports in base<br />
with opt. F. C.<br />
35 mm<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
Valve<br />
(see base)<br />
2<br />
4<br />
12<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
A 18”<br />
1 Non-locking<br />
BA<br />
Flying leads<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
BC<br />
Flying leads with light<br />
DC 24VDC (1.8 W)<br />
x<br />
Other Options<br />
MA<br />
MC<br />
Plug-in wire assy<br />
Plug-in wire assy<br />
DD 24VDC (1.0 W)<br />
with light<br />
AA<br />
120VAC (must use with<br />
HA<br />
Plug-in connector with<br />
rectified connector)<br />
rectifier <strong>and</strong> light<br />
xx<br />
Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
EBM47A-xxxxx-xx<br />
Port size<br />
1/8” NPTF<br />
1/4” NPTF<br />
6 mm tube receptacle<br />
Bottom cylinder ports<br />
(18 mm)<br />
EBM47A-00EBA-XX<br />
EBM47A-00EBB-XX<br />
EBM47A-00EBG-XX<br />
Bottom cylinder ports with flow controls<br />
(18 mm)<br />
EBM47A-00FBA-XX<br />
EBM47A-00FBB-XX<br />
EBM47A-00FBG-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
add-a-unit stations may be added to above bars. Maximum length for add-a-unit is 4 stations.<br />
O P T I O N S<br />
EBM47A-00EBA-XX<br />
- clic replace with “C” for add-a-unit.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• Flow control kit (x2) : N-37001. End plate kit : M-47004-01.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
19.0<br />
6.7<br />
TYP.<br />
BOTH<br />
ENDS<br />
3/8" - 18 N.P.T.F.<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.S.P.TR<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.P.S.PL<br />
2 HOLES<br />
BOTH ENDS<br />
125.18<br />
54.25<br />
27.75<br />
5 1 3<br />
14<br />
14<br />
14<br />
12 12<br />
12<br />
12<br />
14<br />
5<br />
1<br />
3<br />
14.5<br />
41.0<br />
67.5<br />
4<br />
2<br />
4<br />
2<br />
4<br />
2<br />
22.0<br />
30.0<br />
7.00<br />
TYP<br />
99.3<br />
12.0<br />
21.0<br />
16.0<br />
5.20 DIA. THRU.<br />
(4) MTG. HOLES<br />
21.7<br />
TYP.<br />
18.0<br />
25.0<br />
84.6<br />
35.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting Profile<br />
non plug-in<br />
5/2 3/8” 0.5C v<br />
cyl. ports in<br />
valve with<br />
44 mm<br />
opt. Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Valve port size<br />
Valve<br />
2<br />
4<br />
12<br />
14<br />
1/8” NPTF<br />
1/4” NPTF<br />
3 1 5<br />
47A-MG0-HXXX-XXX<br />
47A-MH0-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
A 18”<br />
1 Non-locking<br />
BA<br />
Flying leads<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
BC<br />
Flying leads with light<br />
DC 24VDC (1.8 W)<br />
x<br />
Other Options<br />
MA<br />
MC<br />
Plug-in wire assy<br />
Plug-in wire assy<br />
DD 24VDC (1.0 W)<br />
with light<br />
AA<br />
120VAC (must use with<br />
HA<br />
Plug-in connector with<br />
rectified connector)<br />
rectifier <strong>and</strong> light<br />
xx<br />
Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR (REGULATOR ORDERED SEPARATELY)**<br />
EBM47A-xxxxx-xx<br />
Port size<br />
COMMON INLET & EXHAUST<br />
3/8” NPTF<br />
Without regulator<br />
(20 mm)<br />
EBM47A-01NAK-XX<br />
With regulator<br />
(20 mm)<br />
EBM47A-01PAK-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
** Pressure Regulators :<br />
PR47A-GOAx<br />
X=A (0 to 120 PSI)<br />
X=B (0 to 80 PSI)<br />
X=C (0 to 30 PSI)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
4<br />
4<br />
4<br />
4<br />
2<br />
2<br />
2<br />
2<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47002.<br />
• Regulator blanking plate : R-47003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Dim.<br />
“E”<br />
Regulator with locking<br />
adjusting screw<br />
159.8<br />
Regulator with<br />
adjusting screw<br />
155.6<br />
Regulator with<br />
adjusting knob<br />
163.6<br />
GAGE<br />
GAGE GAGE GAGE<br />
93.6<br />
5.20 DIA.<br />
4 MTG.<br />
HOLES<br />
14<br />
14<br />
14<br />
14<br />
3/8" - 18 N.P.T.F.<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.S.P.TR<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.P.S.PL<br />
2 HOLES<br />
BOTH ENDS<br />
60.8<br />
TYP.<br />
35.4<br />
TYP.<br />
5<br />
1<br />
3<br />
12<br />
12<br />
12<br />
12<br />
3 1 5<br />
19.5<br />
39.2<br />
73.5<br />
TYP.<br />
48.0<br />
TYP.<br />
23.0<br />
TYP.<br />
"E"<br />
10.0<br />
TYP.<br />
20.0<br />
25.0<br />
22.0<br />
TYP.<br />
26.2<br />
90.0<br />
44.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
5/2 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
non plug-in<br />
cyl. ports<br />
in base<br />
44 mm<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
Valve<br />
(see base)<br />
2<br />
4<br />
12<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
A 18”<br />
1 Non-locking<br />
BA<br />
Flying leads<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
BC<br />
Flying leads with light<br />
DC 24VDC (1.8 W)<br />
x<br />
Other Options<br />
MA<br />
MC<br />
Plug-in wire assy<br />
Plug-in wire assy<br />
DD 24VDC (1.0 W)<br />
with light<br />
AA<br />
120VAC (must use with<br />
HA<br />
Plug-in connector with<br />
rectified connector)<br />
rectifier <strong>and</strong> light<br />
xx<br />
Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
1/8” NPTF<br />
1/4” NPTF<br />
6 mm tube receptacle<br />
Side cylinder ports<br />
(18 mm)<br />
EBM47A-00JAA-XX<br />
EBM47A-00JAB-XX<br />
EBM47A-00JAG-XX<br />
EBM47A-xxxxx-xx<br />
Bottom cylinder ports<br />
(18 mm)<br />
EBM47A-00LAA-XX<br />
EBM47A-00LAB-XX<br />
EBM47A-00LAG-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
“D”<br />
DIMENSIONS<br />
Number of<br />
stations<br />
“A”<br />
“B”<br />
“C”<br />
1/4” Port<br />
M6 Carstick port<br />
1<br />
2<br />
3<br />
4<br />
5<br />
- 68.0 86.0 104.0 122.0 140.0 158.0 178.0 194.0 212.0<br />
25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90<br />
28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60<br />
25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00<br />
N/A<br />
6<br />
7<br />
8<br />
9<br />
10<br />
3/8" - 18 N.P.T.F.<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.S.P.TR<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.P.S.PL<br />
2 HOLES<br />
BOTH ENDS<br />
Dimensions are based on<br />
18 mm centerline spacing<br />
59.4<br />
38.3<br />
9.5<br />
34.5<br />
60.75<br />
TYP<br />
35.4<br />
TYP<br />
93.6<br />
2 2<br />
4 4<br />
"D"<br />
18.00<br />
18.00<br />
TYP<br />
"C" "B"<br />
4 4<br />
2 2<br />
"A"<br />
10.0<br />
TYP<br />
5 1 3<br />
12 12 12 12<br />
14 14 14 14<br />
3 1 5<br />
GAGE<br />
5.20 DIA.<br />
2 MTG.<br />
HOLES<br />
1/4" - 18 N.P.T.F.<br />
TYP. 2 PER STATION<br />
1/4" - 19 B.S.P.TR<br />
TYP. 2 PER STATION<br />
1/4" - 19 B.S.P.PL<br />
TYP. 2 PER STATION<br />
44.0<br />
26.20 22.00<br />
TYP TYP<br />
Note: Bottom & side cylinder ports not available on the same station<br />
23.00<br />
TYP<br />
48.00<br />
TYP<br />
73.50<br />
TYP<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
5/2 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
non plug-in<br />
cyl. ports in<br />
base with<br />
Pr. Reg.<br />
44 mm<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
Valve<br />
(see base)<br />
2<br />
4<br />
12<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
A 18”<br />
1 Non-locking<br />
BA<br />
Flying leads<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
BC<br />
Flying leads with light<br />
DC 24VDC (1.8 W)<br />
x<br />
Other Options<br />
MA<br />
MC<br />
Plug-in wire assy<br />
Plug-in wire assy<br />
DD 24VDC (1.0 W)<br />
with light<br />
AA<br />
120VAC (must use with<br />
HA<br />
Plug-in connector with<br />
rectified connector)<br />
rectifier <strong>and</strong> light<br />
xx<br />
Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR (REGULATOR ORDERED SEPARATELY)**<br />
EBM47A-xxxxx-xx<br />
Port size<br />
1/8” NPTF<br />
1/4” NPTF<br />
6 mm tube receptacle<br />
Side cylinder ports<br />
(18 mm)<br />
EBM47A-00KAA-XX<br />
EBM47A-00KAB-XX<br />
EBM47A-00KAG-XX<br />
Bottom cylinder ports<br />
(18 mm)<br />
EBM47A-00MAA-XX<br />
EBM47A-00MAB-XX<br />
EBM47A-00MAG-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
** Pressure Regulators :<br />
PR47A-GOAx<br />
X=A (0 to 120 PSI)<br />
X=B (0 to 80 PSI)<br />
X=C (0 to 30 PSI)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• Regulator blanking plate : R-47003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
3/8" - 18 N.P.T.F.<br />
2 HOLES<br />
BOTH ENDS<br />
“A”<br />
- 68.0 86.0 104.0 122.0 140.0 158.0 178.0 194.0 212.0<br />
“B”<br />
“C”<br />
1/4” Port<br />
25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90<br />
28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60<br />
25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00<br />
“D”<br />
M6 Carstick port<br />
N/A<br />
3/8" - 19 B.S.P.TR<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.P.S.PL<br />
2 HOLES<br />
BOTH ENDS<br />
Dimensions are based on<br />
18 mm centerline spacing<br />
59.4<br />
38.3<br />
9.5<br />
34.5<br />
60.75<br />
TYP<br />
35.4<br />
TYP<br />
93.6<br />
2 2<br />
4 4<br />
"D"<br />
18.00<br />
18.00<br />
TYP<br />
"C" "B"<br />
4 4<br />
2 2<br />
"A"<br />
10.0<br />
TYP<br />
3<br />
12 12 12 12<br />
5 1<br />
14 14 14 14<br />
3 1 5<br />
GAGE<br />
5.20 DIA.<br />
2 MTG.<br />
HOLES<br />
"E"<br />
1/4" - 18 N.P.T.F.<br />
TYP. 2 PER STATION<br />
1/4" - 19 B.S.P.TR<br />
TYP. 2 PER STATION<br />
1/4" - 19 B.S.P.PL<br />
TYP. 2 PER STATION<br />
Note: Bottom & side cylinder ports not available on the same station<br />
Dim.<br />
“E”<br />
Regulator with locking<br />
adjusting screw<br />
159.8<br />
Regulator with<br />
adjusting screw<br />
155.6<br />
Regulator with<br />
adjusting knob<br />
163.6<br />
44.0<br />
26.20 22.00<br />
TYP TYP<br />
23.00<br />
TYP<br />
48.00<br />
TYP<br />
73.50<br />
TYP<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
5/2 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
add-on style<br />
non plug-in<br />
cyl. ports in<br />
base<br />
44 mm<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
Valve<br />
(see base)<br />
2<br />
4<br />
12<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
A 18”<br />
1 Non-locking<br />
BA<br />
Flying leads<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
BC<br />
Flying leads with light<br />
DC 24VDC (1.8 W)<br />
x<br />
Other Options<br />
MA<br />
MC<br />
Plug-in wire assy<br />
Plug-in wire assy<br />
DD 24VDC (1.0 W)<br />
with light<br />
AA<br />
120VAC (must use with<br />
HA<br />
Plug-in connector with<br />
rectified connector)<br />
rectifier <strong>and</strong> light<br />
xx<br />
Other Options<br />
xx<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
EBM47A-xxxxx-xx<br />
Port size<br />
1/8” NPTF<br />
1/4” NPTF<br />
6 mm tube receptacle<br />
Side cylinder ports<br />
(18 mm)<br />
EBM47A-00JBA-XX<br />
EBM47A-00JBB-XX<br />
EBM47A-00JBG-XX<br />
Bottom cylinder ports<br />
(18 mm)<br />
EBM47A-00LBA-XX<br />
EBM47A-00LBB-XX<br />
EBM47A-00LBG-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
add-a-unit stations may be added to above bars. Maximum length for add-a-unit is 4 stations.<br />
O P T I O N S<br />
EBM47A-00JBA-XX<br />
- clic replace with “C” for add-a-unit.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• End plate kit : M-47005-01.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of 1 2 3 4 5 6 7 8 9 10<br />
stations<br />
“C” w/regulator<br />
“C” w/o regulator<br />
-<br />
-<br />
56.1<br />
56.1<br />
74.1<br />
74.1<br />
92.1<br />
92.1<br />
110.1 128.1 146.1 164.1 182.1 200.1<br />
110.1 128.1 146.1 164.1 182.1 200.1<br />
“D” 21.7 39.7 57.7 75.7 - - - - - -<br />
Dimensions are based on 18 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
44.0<br />
3/8" - 18 N.P.T.F.<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.S.P.TR<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.P.S.PL<br />
2 HOLES<br />
BOTH ENDS<br />
93.6<br />
59.4<br />
38.3<br />
9.5<br />
34.5<br />
16.0<br />
5 1 3<br />
5.20 DIA.<br />
2 MTG.<br />
HOLES<br />
2<br />
2<br />
4 4<br />
10.85<br />
18.00<br />
18.00<br />
25.00 "B" "A"<br />
4<br />
2<br />
"D"<br />
"C"<br />
10.0<br />
TYP<br />
12<br />
12 12<br />
3 1<br />
35.4<br />
TYP<br />
60.75<br />
TYP<br />
14 14<br />
14<br />
5<br />
GAGE<br />
1/4" - 18 N.P.T.F.<br />
TYP. 2 PER STATION<br />
1/4" - 19 B.S.P.TR<br />
TYP. 2 PER STATION<br />
1/4" - 19 B.S.P.PL<br />
TYP. 2 PER STATION<br />
1/8" - 27 N.P.T.F.<br />
TYP. 2 PER STATION<br />
1/8" - 28 B.S.P.TR.<br />
TYP. 2 PER STATION<br />
1/8" - 28 B.S.P.PL.<br />
TYP. 2 PER STATION<br />
26.20 22.00<br />
TYP TYP<br />
Dim.<br />
“A”<br />
1/4”<br />
25.90<br />
M6 Carstick<br />
25.90<br />
* M6 Carstick available only on side port<br />
23.00<br />
TYP<br />
48.00<br />
TYP<br />
73.50<br />
TYP<br />
“B”<br />
28.60<br />
28.60<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting Profile<br />
5/2 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
OPERATIONAL BENEFITS<br />
1. Direct solenoid operated valve.<br />
2. Balanced poppet, immune to variations of<br />
pressure.<br />
3. Short stroke with high flow.<br />
4. The patented solenoid develops high shifting<br />
forces.<br />
5. Powerful return spring.<br />
6. Manual operator st<strong>and</strong>ard on all valves.<br />
add-on style<br />
non plug-in cyl.<br />
ports in base<br />
with Pr. Reg.<br />
44 mm<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-Hxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
(see base)<br />
12<br />
2<br />
Valve<br />
4<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
A 18”<br />
DB 24VDC (2.4 W)<br />
C 36”<br />
DC 24VDC (1.8 W)<br />
x Other Options<br />
DD 24VDC (1.0 W)<br />
AA 120VAC (must use with<br />
rectified connector)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR (REGULATOR ORDERED SEPARATELY)**<br />
1 Non-locking<br />
BA Flying leads<br />
BC Flying leads with light<br />
MA Plug-in wire assy<br />
MC Plug-in wire assy<br />
with light<br />
HA Plug-in connector with<br />
rectifier <strong>and</strong> light<br />
xx Other Options<br />
EBM47A-xxxxx-xx<br />
Port size<br />
1/8” NPTF<br />
1/4” NPTF<br />
6 mm tube receptacle<br />
Side cylinder ports<br />
(18 mm)<br />
EBM47A-00KBA-XX<br />
EBM47A-00KBB-XX<br />
EBM47A-00KBG-XX<br />
Bottom cylinder ports<br />
(18 mm)<br />
EBM47A-00MBA-XX<br />
EBM47A-00MBB-XX<br />
EBM47A-00MBG-XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
add-a-unit stations may be added to above bars. Maximum length for add-a-unit is 4 stations.<br />
O P T I O N S<br />
EBM47A-00KBA-XX<br />
- clic replace with “C” for add-a-unit.<br />
Consult “Precautions”before use, installation or service of MAC Valves.<br />
** Pressure Regulators :<br />
PR47A-GOAx<br />
X=A (0 to 120 PSI)<br />
X=B (0 to 80 PSI)<br />
X=C (0 to 30 PSI)
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• End plate kit : M-47005-01. • Regulator blanking plate : R-47003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of 1 2 3 4 5 6 7 8 9 10<br />
stations<br />
“C” w/regulator<br />
“C” w/o regulator<br />
-<br />
-<br />
56.1<br />
56.1<br />
74.1<br />
74.1<br />
92.1<br />
92.1<br />
110.1 128.1 146.1 164.1 182.1 200.1<br />
110.1 128.1 146.1 164.1 182.1 200.1<br />
“D” 21.7 39.7 57.7 75.7 - - - - - -<br />
Dimensions are based on 18 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
44.0<br />
3/8" - 18 N.P.T.F.<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.S.P.TR<br />
2 HOLES<br />
BOTH ENDS<br />
3/8" - 19 B.P.S.PL<br />
2 HOLES<br />
BOTH ENDS<br />
93.6<br />
59.4<br />
38.3<br />
9.5<br />
34.5<br />
"E"<br />
16.0<br />
5 1 3<br />
5.20 DIA.<br />
2 MTG.<br />
HOLES<br />
2<br />
2<br />
4 4<br />
10.85<br />
18.00<br />
18.00<br />
25.00 "B" "A"<br />
4<br />
2<br />
"D"<br />
"C"<br />
10.0<br />
TYP<br />
12<br />
12 12<br />
3 1<br />
35.4<br />
TYP<br />
60.75<br />
TYP<br />
14 14<br />
14<br />
5<br />
GAGE<br />
1/4" - 18 N.P.T.F.<br />
TYP. 2 PER STATION<br />
1/4" - 19 B.S.P.TR<br />
TYP. 2 PER STATION<br />
1/4" - 19 B.S.P.PL<br />
TYP. 2 PER STATION<br />
1/8" - 27 N.P.T.F.<br />
TYP. 2 PER STATION<br />
1/8" - 28 B.S.P.TR.<br />
TYP. 2 PER STATION<br />
1/8" - 28 B.S.P.PL.<br />
TYP. 2 PER STATION<br />
Dim.<br />
1/4”<br />
M6 Carstick<br />
* M6 Carstick available only on side port<br />
26.20 22.00<br />
TYP TYP<br />
“A”<br />
“B”<br />
Dim.<br />
“E”<br />
25.90<br />
28.60<br />
25.90<br />
28.60<br />
Regulator with locking<br />
adjusting screw<br />
158.8<br />
Regulator with<br />
adjusting screw<br />
155.6<br />
Regulator with<br />
adjusting knob<br />
163.6<br />
23.00<br />
TYP<br />
48.00<br />
TYP<br />
73.50<br />
TYP<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
plug-in<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Direct solenoid operated.<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />
Valve<br />
2<br />
4<br />
12<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
DB 24VDC (2.4 W)<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DD 24VDC (1.0 W)<br />
FG Plug-in with suppression diode<br />
AA 120VAC (Mod. No. required see below)<br />
with LED light<br />
xx Other Options<br />
xx Other Options<br />
FA<br />
FC<br />
FE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR<br />
ECD47A-xxxxx-xxxx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
18<br />
ECD47A-00AAA-A0XX<br />
ECD47A-00BAA-A0XX<br />
1/4” NPTF<br />
18<br />
ECD47A-00AAB-A0XX<br />
ECD47A-00BAB-A0XX<br />
6 mm tube receptacle<br />
18<br />
ECD47A-00AAG-A0XX<br />
ECD47A-00BAG-A0XX<br />
1/8” NPTF<br />
30<br />
ECD47A-01AAA-C0XX<br />
ECD47A-01BAA-C0XX<br />
1/4” NPTF<br />
30<br />
ECD47A-01AAB-C0XX<br />
ECD47A-01BAB-C0XX<br />
6 mm tube receptacle<br />
30<br />
ECD47A-01AAG-C0XX<br />
ECD47A-01BAG-C0XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
for multi-pin connector (9, 15 or 25).<br />
Consult “Precautions”before use, installation or service of MAC Valves.<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• Base wire plug-in protector : 16520.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
“E”<br />
46.0<br />
64.0<br />
82.0<br />
100.0 118.0 136.0 154.0 172.0 190.0 208.0<br />
Dimensions are based on 18 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
136.5<br />
3/8 N.P.T.F.<br />
3 HOLES<br />
BOTH ENDS<br />
SHOWN W\ STANDARD<br />
REGULATOR<br />
COND.<br />
5<br />
1<br />
3<br />
79.5<br />
40.7<br />
20.35<br />
44.0<br />
19.0 23.2<br />
28.0<br />
TYP. TYP. TYP.<br />
59.05<br />
TYP. 6.0<br />
TYP.<br />
21.0<br />
TYP.<br />
45.1<br />
TYP.<br />
73.0<br />
TYP.<br />
107.5<br />
TYP.<br />
D<br />
14<br />
14<br />
12<br />
12<br />
2<br />
18.0<br />
TYP.<br />
E<br />
14<br />
14<br />
2<br />
12<br />
4<br />
2<br />
4<br />
12<br />
4<br />
COND.<br />
5<br />
1<br />
3<br />
6.25 DIA.<br />
2 MTG.<br />
HOLES<br />
1"-11 1/2 N.P.S.M. CONDUIT<br />
34.5<br />
9.5<br />
C<br />
A<br />
B<br />
23.0 23.0<br />
18.0<br />
TYP.<br />
18.0<br />
TYP.<br />
2<br />
4<br />
18.0<br />
TYP.<br />
Dim.<br />
1/4”<br />
1/8”<br />
6 mm Legris<br />
“A”<br />
26.65<br />
26.15<br />
25.65<br />
“B”<br />
26.65<br />
24.2<br />
25.65<br />
“C”<br />
33.1<br />
34.8<br />
34.8<br />
“D”<br />
58.4<br />
55.9<br />
55.9<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 1/8” - 1/4” 0.5C v<br />
plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Direct solenoid operated.<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />
Valve<br />
12<br />
2<br />
4<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
DB 24VDC (2.4 W)<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DD 24VDC (1.0 W)<br />
FG Plug-in with suppression diode<br />
AA 120VAC (Mod. No. required see below)<br />
with LED light<br />
xx Other Options<br />
xx Other Options<br />
FA<br />
FC<br />
FE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />
ECD47A-xxxxx-xxxx<br />
Port size<br />
Spacing mm<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
1/4” NPTF<br />
1/8” NPTF<br />
1/4” NPTF<br />
18<br />
18<br />
30<br />
30<br />
ECD47A-00CAA-A0XX<br />
ECD47A-00CAB-A0XX<br />
ECD47A-01CAA-C0XX<br />
ECD47A-01CAB-C0XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
for multi-pin connector (9, 15 or 25).<br />
** Pressure Regulators :<br />
PR47A-GOAx<br />
X=A (0 to 120 PSI)<br />
X=B (0 to 80 PSI)<br />
X=C (0 to 30 PSI)<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• Base wire plug-in protector : 16520. • Regulator blanking plate : R-47003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
“E”<br />
46.0<br />
64.0<br />
82.0<br />
100.0 118.0 136.0 154.0 172.0 190.0 208.0<br />
Dimensions are based on 18 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
F<br />
G<br />
SHOWN W\ SANDWICH<br />
REGULATOR<br />
136.5<br />
3/8 N.P.T.F.<br />
3 HOLES<br />
BOTH ENDS<br />
SHOWN W\ STANDARD<br />
REGULATOR<br />
COND.<br />
5<br />
1<br />
3<br />
79.5<br />
40.7<br />
20.35<br />
44.0<br />
19.0 23.2<br />
28.0<br />
TYP. TYP. TYP.<br />
59.05<br />
TYP. 6.0<br />
TYP.<br />
21.0<br />
TYP.<br />
45.1<br />
TYP.<br />
73.0<br />
TYP.<br />
107.5<br />
TYP.<br />
D<br />
14<br />
14<br />
14<br />
12<br />
12<br />
12<br />
2<br />
18.0<br />
TYP.<br />
E<br />
14<br />
12<br />
2<br />
4<br />
COND.<br />
5<br />
1<br />
3<br />
6.25 DIA.<br />
2 MTG.<br />
HOLES<br />
1"-11 1/2 N.P.S.M. CONDUIT<br />
34.5<br />
9.5<br />
C<br />
A<br />
B<br />
23.0 23.0<br />
Dim.<br />
1/4”<br />
1/8”<br />
6 mm Legris<br />
18.0<br />
TYP.<br />
18.0<br />
TYP.<br />
2<br />
4<br />
18.0<br />
TYP.<br />
“A”<br />
“B”<br />
“C”<br />
26.65<br />
26.65<br />
33.1<br />
26.15<br />
24.2<br />
34.8<br />
25.65<br />
25.65<br />
34.8<br />
4<br />
2<br />
4<br />
“D”<br />
58.4<br />
55.9<br />
55.9<br />
109.2<br />
Dim.<br />
“F”<br />
Regulator with locking<br />
adjusting screw<br />
209.3<br />
Regulator with<br />
adjusting screw<br />
205.1<br />
Regulator with<br />
adjusting knob<br />
212.1<br />
“G”<br />
204.3<br />
200.1<br />
207.1<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
add-on style<br />
plug-in<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Direct solenoid operated.<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />
Valve<br />
2<br />
4<br />
12<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
DB 24VDC (2.4 W)<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DD 24VDC (1.0 W)<br />
FG Plug-in with suppression diode<br />
AA 120VAC (Mod. No. required see below)<br />
with LED light<br />
xx Other Options<br />
xx Other Options<br />
FA<br />
FC<br />
FE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR<br />
ECD47A-xxxxx-xxxx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
18<br />
ECD47A-00ABA-A0XX<br />
ECD47A-00BBA-A0XX<br />
1/4” NPTF<br />
18<br />
ECD47A-00ABB-A0XX<br />
ECD47A-00BBB-A0XX<br />
6 mm tube receptacle<br />
18<br />
ECD47A-00ABG-A0XX<br />
ECD47A-00BBG-A0XX<br />
1/8” NPTF<br />
30<br />
ECD47A-01ABA-C0XX<br />
ECD47A-01BBA-C0XX<br />
1/4” NPTF<br />
30<br />
ECD47A-01ABB-C0XX<br />
ECD47A-01BBB-C0XX<br />
6 mm tube receptacle<br />
30<br />
ECD47A-01ABG-C0XX<br />
ECD47A-01BBG-C0XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
for multi-pin connector (9, 15 or 25).<br />
add-a-units may be added to above bars.<br />
Consult “Precautions”before use, installation or service of MAC Valves.<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)
2<br />
4<br />
2<br />
4<br />
2<br />
4<br />
2<br />
4<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• Base wire plug-in protector : 16520. • Isolator disc between add-a-units : 28438.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
“G”<br />
“H”<br />
1<br />
2<br />
3<br />
4<br />
5<br />
- 51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />
21.70 39.70 57.70 75.70 - - - - - -<br />
6<br />
7<br />
8<br />
9<br />
10<br />
137.7<br />
1"-11 1/2 N.P.S.M. CONDUIT<br />
Dimensions are based on 18 mm centerline spacing<br />
1 3<br />
COND.<br />
Note: Bottom & side cylinder ports not available on the same station<br />
5<br />
79.2<br />
3/8" N.PT.F.<br />
TYP.(3) BOTH ENDS<br />
E<br />
16.0<br />
4<br />
2<br />
12.05<br />
F<br />
12<br />
14<br />
H<br />
4<br />
2<br />
13.0<br />
12<br />
14<br />
4<br />
4<br />
2<br />
2<br />
16.7<br />
18.0<br />
TYP.<br />
26.15<br />
12<br />
A<br />
12<br />
14<br />
14<br />
G<br />
D<br />
C<br />
B<br />
9.5<br />
TYP.<br />
34.5<br />
TYP.<br />
6.0 59.05<br />
TYP. TYP.<br />
6.25 DIA. HOLE<br />
TYP.(2)<br />
44.0<br />
40.7<br />
23.2 19.0<br />
3<br />
5<br />
20.35 28.0<br />
TYP. TYP. 1 COND. TYP. TYP.<br />
Dim.<br />
“A”<br />
“B”<br />
“C”<br />
“D”<br />
“E”<br />
1/8”<br />
24.20<br />
23.00<br />
34.80<br />
55.90<br />
-<br />
1/4”<br />
24.20<br />
23.00<br />
33.10<br />
58.40<br />
-<br />
6 mm Legris<br />
25.65<br />
23.00<br />
34.80<br />
55.90<br />
-<br />
21.0<br />
TYP.<br />
45.1<br />
TYP.<br />
73.0<br />
TYP.<br />
107.5<br />
TYP.<br />
“F”<br />
12.05<br />
12.00<br />
14.00<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 1/8” - 1/4” 0.5C v<br />
add-on style<br />
plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Direct solenoid operated.<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />
Valve<br />
12<br />
2<br />
4<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
DB 24VDC (2.4 W)<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DD 24VDC (1.0 W)<br />
FG Plug-in with suppression diode<br />
AA 120VAC (Mod. No. required see below)<br />
with LED light<br />
xx Other Options<br />
xx Other Options<br />
FA<br />
FC<br />
FE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />
ECD47A-xxxxx-xxxx<br />
Port size<br />
Spacing mm<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
1/4” NPTF<br />
1/8” NPTF<br />
1/4” NPTF<br />
18<br />
18<br />
30<br />
30<br />
ECD47A-00CBA-A0XX<br />
ECD47A-00CBB-A0XX<br />
ECD47A-01CBA-C0XX<br />
ECD47A-01CBB-C0XX<br />
Number of stations (03=3 stations)<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
for multi-pin connector (9, 15 or 25).<br />
add-a-units may be added to above bars.<br />
** Pressure Regulators :<br />
PR47A-GOAx<br />
X=A (0 to 120 PSI)<br />
X=B (0 to 80 PSI)<br />
X=C (0 to 30 PSI)<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• Base wire plug-in protector : 16520. • Regulator blanking plate : R-47003. • Isolator disc between add-a-units : 28438.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
“G” w/regulator<br />
1<br />
-<br />
2<br />
3<br />
4<br />
5<br />
6<br />
54.40 72.40 90.40 108.40 126.40 144.40 162.40 180.40 199.40<br />
7<br />
8<br />
9<br />
10<br />
SHOWN W/STANDARD<br />
REGULATOR<br />
J<br />
137.7<br />
1"-11 1/2 N.P.S.M. CONDUIT<br />
“G” w/o regulator - 51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />
“H” w/regulator 24.25 42.25 60.25 78.25 - - - - - -<br />
1 3<br />
COND.<br />
“H” w/o regulator 21.70 39.70 57.70 75.70<br />
Dimensions are based on 18 mm<br />
centerline spacing<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
3/8" N.PT.F.<br />
TYP.(3) BOTH ENDS<br />
5<br />
79.2<br />
Note: Bottom & side cylinder ports not<br />
available on the same station<br />
E<br />
16.0<br />
4<br />
2<br />
12.05<br />
F<br />
12<br />
14<br />
H<br />
4<br />
2<br />
13.0<br />
4<br />
2<br />
12<br />
14<br />
4<br />
16.7<br />
18.0<br />
TYP.<br />
26.15<br />
12<br />
4<br />
2<br />
2<br />
A<br />
2<br />
4<br />
12<br />
14<br />
14<br />
G<br />
D<br />
C<br />
B<br />
9.5<br />
TYP.<br />
34.5<br />
TYP.<br />
6.0 59.05<br />
TYP. TYP.<br />
K<br />
SHOWN W/SANDWICH<br />
REGULATOR<br />
6.25 DIA. HOLE<br />
TYP.(2)<br />
Dim.<br />
“A”<br />
“B”<br />
“C”<br />
“D”<br />
“E”<br />
“F”<br />
Dim.<br />
“J”<br />
“K”<br />
1/8”<br />
24.20<br />
23.00<br />
34.80<br />
55.90<br />
-<br />
12.05<br />
1/4”<br />
24.20<br />
23.00<br />
33.10<br />
58.40<br />
-<br />
12.00<br />
Regulator with locking<br />
adjusting screw<br />
209.3<br />
204.3<br />
6 mm Legris<br />
25.65<br />
23.00<br />
34.80<br />
55.90<br />
-<br />
14.00<br />
1/8” w/regulator<br />
-<br />
-<br />
34.80<br />
55.90<br />
10.75<br />
-<br />
1/4” w/regulator<br />
-<br />
23.00<br />
33.10<br />
58.40<br />
10.85<br />
-<br />
Regulator with<br />
adjusting screw<br />
205.1<br />
200.1<br />
Regulator with<br />
adjusting knob<br />
212.1<br />
207.1<br />
103.0<br />
44.0<br />
40.7<br />
23.2 19.0<br />
3<br />
5<br />
20.35 28.0<br />
TYP. TYP. 1 COND. TYP. TYP.<br />
21.0<br />
TYP.<br />
45.1<br />
TYP.<br />
73.0<br />
TYP.<br />
107.5<br />
TYP.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 1/8” - 1/4” 0.5C v<br />
6 mm tube receptacle<br />
plug-in<br />
add-a-unit<br />
stations<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Direct solenoid operated.<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />
Valve<br />
2<br />
4<br />
12<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
DB 24VDC (2.4 W)<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DD 24VDC (1.0 W)<br />
FG Plug-in with suppression diode<br />
AA 120VAC (Mod. No. required see below)<br />
with LED light<br />
xx Other Options<br />
xx Other Options<br />
FA<br />
FC<br />
FE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR<br />
ECD47A-xxxxx-xxxx<br />
Port size<br />
Spacing<br />
mm<br />
Side cylinder ports<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
18<br />
ECD47A-00ACA-A0XX<br />
ECD47A-00BCA-A0XX<br />
1/4” NPTF<br />
18<br />
ECD47A-00ACB-A0XX<br />
ECD47A-00BCB-A0XX<br />
6 mm tube receptacle<br />
18<br />
ECD47A-00ACG-A0XX<br />
ECD47A-00BCG-A0XX<br />
1/8” NPTF<br />
30<br />
ECD47A-01ACA-C0XX<br />
ECD47A-01BCA-C0XX<br />
1/4” NPTF<br />
30<br />
ECD47A-01ACB-C0XX<br />
ECD47A-01BCB-C0XX<br />
6 mm tube receptacle<br />
30<br />
ECD47A-01ACG-C0XX<br />
ECD47A-01BCG-C0XX<br />
Number of stations (01=1 station). Maximum length is 4 stations<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
when add-a-unit stations are added to bars with a multi-pin connector,<br />
MOD SD03 should be included with add-a-unit model number.<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
Consult “Precautions”before use, installation or service of MAC Valves.<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)
2<br />
4<br />
2<br />
4<br />
2<br />
4<br />
2<br />
4<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• O-ring port seal (x3) : 17015-01 • Tie rod (x2) : 79007-01 (one station length).<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
“G”<br />
“H”<br />
1<br />
2<br />
3<br />
4<br />
5<br />
- 51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />
21.70 39.70 57.70 75.70 - - - - - -<br />
6<br />
7<br />
8<br />
9<br />
10<br />
137.7<br />
1"-11 1/2 N.P.S.M. CONDUIT<br />
Dimensions are based on 18 mm centerline spacing<br />
1 3<br />
COND.<br />
Note: Bottom & side cylinder ports not available on the same station<br />
5<br />
79.2<br />
3/8" N.PT.F.<br />
TYP.(3) BOTH ENDS<br />
E<br />
16.0<br />
4<br />
2<br />
12.05<br />
F<br />
12<br />
14<br />
H<br />
4<br />
2<br />
13.0<br />
12<br />
14<br />
4<br />
4<br />
2<br />
2<br />
16.7<br />
18.0<br />
TYP.<br />
26.15<br />
12<br />
A<br />
12<br />
14<br />
14<br />
G<br />
D<br />
C<br />
B<br />
9.5<br />
TYP.<br />
34.5<br />
TYP.<br />
6.0 59.05<br />
TYP. TYP.<br />
6.25 DIA. HOLE<br />
TYP.(2)<br />
44.0<br />
40.7<br />
23.2 19.0<br />
3<br />
5<br />
20.35 28.0<br />
TYP. TYP. 1 COND. TYP. TYP.<br />
Dim.<br />
“A”<br />
“B”<br />
“C”<br />
“D”<br />
“E”<br />
1/8”<br />
24.20<br />
23.00<br />
34.80<br />
55.90<br />
-<br />
1/4”<br />
24.20<br />
23.00<br />
33.10<br />
58.40<br />
-<br />
6 mm Legris<br />
25.65<br />
23.00<br />
34.80<br />
55.90<br />
-<br />
21.0<br />
TYP.<br />
45.1<br />
TYP.<br />
73.0<br />
TYP.<br />
107.5<br />
TYP.<br />
“F”<br />
12.05<br />
12.00<br />
14.00<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 47<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 1/8” - 1/4” 0.5C v<br />
add-a-unit<br />
stations<br />
plug-in<br />
with Pr. Reg.<br />
OPERATIONAL BENEFITS<br />
1. Balanced poppet, immune to variations of<br />
pressure.<br />
2. Short stroke with high flow.<br />
3. The patented solenoid develops high shifting<br />
forces.<br />
4. Powerful return spring.<br />
5. Manual operator st<strong>and</strong>ard on all valves.<br />
6. Direct solenoid operated.<br />
Reset<br />
HOW TO ORDER<br />
47A-xxx-HxxP-xxx<br />
HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />
Valve<br />
12<br />
2<br />
4<br />
14<br />
Valve less base<br />
3 1 5<br />
47A-LI0-HXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
H XX P- X XX *<br />
XX Voltage<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
DA 24VDC (5.2 W)<br />
DB 24VDC (2.4 W)<br />
DC 24VDC (1.8 W)<br />
1 Non-locking<br />
DD 24VDC (1.0 W)<br />
FG Plug-in with suppression diode<br />
AA 120VAC (Mod. No. required see below)<br />
with LED light<br />
xx Other Options<br />
xx Other Options<br />
FA<br />
FC<br />
FE<br />
Plug-in<br />
Plug-in with light<br />
Plug-in with suppression diode<br />
HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />
ECD47A-xxxxx-xxxx<br />
Port size<br />
Spacing mm<br />
Bottom cylinder ports<br />
1/8” NPTF<br />
1/4” NPTF<br />
1/8” NPTF<br />
1/4” NPTF<br />
18<br />
18<br />
30<br />
30<br />
ECD47A-00CCA-A0XX<br />
ECD47A-00CCB-A0XX<br />
ECD47A-01CCA-C0XX<br />
ECD47A-01CCB-C0XX<br />
Number of stations (01=1 station). Maximum length is 4 stations<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
when add-a-unit stations are added to bars with a multi-pin connector,<br />
MOD SD03 should be included with add-a-unit model number.<br />
for AC voltage use mod. FWR2 after circuit bar model number.<br />
** Pressure Regulators :<br />
PR47A-GOAx<br />
X=A (0 to 120 PSI)<br />
X=B (0 to 80 PSI)<br />
X=C (0 to 30 PSI)<br />
A0 = without light<br />
AA = with light (120V)<br />
AB = with light (240V)<br />
AD = with light (24V)<br />
C0 = terminal strip<br />
CA = terminal strip with light (120V)<br />
CB = terminal strip with light (240V)<br />
CD = terminal strip with light (24V)<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 47<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Power :<br />
Response times :<br />
(with 5.2 W coil)<br />
Compressed air, vacuum, inert gases<br />
Vacuum to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to 50°C)<br />
4.3 mm<br />
5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
5.2 W - 2.4 W - 1.8 W - 1.0 W<br />
Energize : 14.0 ms<br />
De-energize : 5.0 ms<br />
Note :<br />
Spare parts :<br />
Options :<br />
• Valve <strong>and</strong> coil are not interchangeable.<br />
• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />
• O-ring port seal (x3) : 17015-01 • Tie rod (x2) : 79007-01 (one station length). • Regulator blanking plate : R-47003.<br />
• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />
DIMENSIONS<br />
Number of<br />
stations<br />
“G” w/regulator<br />
1<br />
-<br />
2<br />
3<br />
4<br />
5<br />
6<br />
54.40 72.40 90.40 108.40 126.40 144.40 162.40 180.40 199.40<br />
7<br />
8<br />
9<br />
10<br />
SHOWN W/STANDARD<br />
REGULATOR<br />
J<br />
137.7<br />
1"-11 1/2 N.P.S.M. CONDUIT<br />
“G” w/o regulator - 51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />
“H” w/regulator 24.25 42.25 60.25 78.25 - - - - - -<br />
1 3<br />
COND.<br />
“H” w/o regulator 21.70 39.70 57.70 75.70<br />
Dimensions are based on 18 mm<br />
centerline spacing<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
3/8" N.PT.F.<br />
TYP.(3) BOTH ENDS<br />
5<br />
79.2<br />
Note: Bottom & side cylinder ports not<br />
available on the same station<br />
E<br />
16.0<br />
4<br />
2<br />
12.05<br />
F<br />
12<br />
14<br />
H<br />
4<br />
2<br />
13.0<br />
4<br />
2<br />
12<br />
14<br />
4<br />
16.7<br />
18.0<br />
TYP.<br />
26.15<br />
12<br />
4<br />
2<br />
2<br />
A<br />
2<br />
4<br />
12<br />
14<br />
14<br />
G<br />
D<br />
C<br />
B<br />
9.5<br />
TYP.<br />
34.5<br />
TYP.<br />
6.0 59.05<br />
TYP. TYP.<br />
K<br />
SHOWN W/SANDWICH<br />
REGULATOR<br />
6.25 DIA. HOLE<br />
TYP.(2)<br />
Dim.<br />
“A”<br />
“B”<br />
“C”<br />
“D”<br />
“E”<br />
“F”<br />
Dim.<br />
“J”<br />
“K”<br />
1/8”<br />
24.20<br />
23.00<br />
34.80<br />
55.90<br />
-<br />
12.05<br />
1/4”<br />
24.20<br />
23.00<br />
33.10<br />
58.40<br />
-<br />
12.00<br />
Regulator with locking<br />
adjusting screw<br />
209.3<br />
204.3<br />
6 mm Legris<br />
25.65<br />
23.00<br />
34.80<br />
55.90<br />
-<br />
14.00<br />
1/8” w/regulator<br />
-<br />
-<br />
34.80<br />
55.90<br />
10.75<br />
-<br />
1/4” w/regulator<br />
-<br />
23.00<br />
33.10<br />
58.40<br />
10.85<br />
-<br />
Regulator with<br />
adjusting screw<br />
205.1<br />
200.1<br />
Regulator with<br />
adjusting knob<br />
212.1<br />
207.1<br />
103.0<br />
44.0<br />
40.7<br />
23.2 19.0<br />
3<br />
5<br />
20.35 28.0<br />
TYP. TYP. 1 COND. TYP. TYP.<br />
21.0<br />
TYP.<br />
45.1<br />
TYP.<br />
73.0<br />
TYP.<br />
107.5<br />
TYP.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Section 2 Options<br />
Consult “Precautions” before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Codification table for voltages / Wire length / Manual operators / Electrical connections<br />
VALVE CODE ➤<br />
- H XX X - X XX<br />
1 2 3 4<br />
OPTIONS AVAILABLE FOR<br />
- Solenoid valves 37 & 47 Series<br />
Consult “Precautions”before use, installation or service of MAC Valves.
OPTIONS<br />
Back<br />
1. VOLTAGE<br />
- H XX X - X XX VOLTAGE<br />
DC Options<br />
DA 24 VDC (5.2 W)<br />
DB 24 VDC (2.4 W)<br />
DC 24 VDC (1.8 W)<br />
DD 24 VDC (1.0 W)<br />
DF 12 VDC (5.2 W)<br />
DG 12 VDC (2.4 W)<br />
DH 12 VDC (1.8 W)<br />
DJ 12 VDC (1.0 W)<br />
DL 120 VDC (6.3 W)<br />
AC Options (50/60hz)<br />
AA 120 VAC (6.7 W)<br />
AB 220 VAC (5.6 W)<br />
AC 240 VAC (5.8 W)<br />
AD 24 VAC (7.8 W)<br />
Note : AC Voltages only available with “H” & “F” type connectors. MOD FWR2 must be used with the “F” type connectors.<br />
2. WIRE LENGTH<br />
- H XX X - X XX WIRE LENGTH<br />
O<br />
No lead wire<br />
A 18”<br />
B 24”<br />
C 36”<br />
D 48”<br />
E 72”<br />
F 96”<br />
G 120”<br />
H 144”<br />
P<br />
Plug-in (used only with “F”type connector Opts.)<br />
Use “O” with MJ & MM Opts.<br />
3. MANUAL OPERATOR<br />
- H XX X - X XX MANUAL OPERATOR<br />
0 No operator<br />
1 Non-locking recessed<br />
2 Locking recessed<br />
3 Non-locking extended<br />
4 Locking extended<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Back<br />
4. ELECTRICAL CONNECTION<br />
- H XX X - X XX ELECTRICAL CONNECTION<br />
BA Flying leads<br />
BB Flying leads with ground wire<br />
BC Flying leads with led light<br />
BD Flying leads with led light & ground wire<br />
BE Flying leads with suppression diode<br />
BF Flying leads with suppression diode & ground wire<br />
BG Flying leads with suppression diode plus led light<br />
BH Flying leads with suppression diode plus led light & ground wire<br />
*BN Flying leads with suppression diode plus blocking diode<br />
*BP Flying leads with suppression diode plus blocking diode & ground wire<br />
*BR Flying leads with suppression diode plus blocking diode & led light<br />
*BS Flying leads with suppression diode plus blocking diode & led light & ground wire<br />
FA<br />
FB<br />
FC<br />
FD<br />
FE<br />
FF<br />
FG<br />
FH<br />
Plug-in<br />
Plug-in with ground wire<br />
Plug-in with led light<br />
Plug-in with led light & ground wire<br />
Plug-in with suppression diode<br />
Plug-in with suppression diode & ground wire<br />
Plug-in with suppression diode plus led light<br />
Plug-in with suppression diode plus led light & ground wire<br />
Note : FA ---- FH options for use with ECD type circuit bars<br />
HA<br />
HB<br />
HC<br />
HD<br />
HL<br />
HN<br />
Circuit board plug-in with full wave rectifier & led light<br />
Circuit board with full wave rectifier & led with ground wire<br />
Same as “HA” without lead wires<br />
Same as “HB” without lead wires<br />
Circuit board plug-in with suppression diode plus blocking diode & led light<br />
Same as “HL” without lead wires<br />
MA Plug-in wire assembly<br />
MB Plug-in wire assembly with ground wire<br />
MC Plug-in wire assembly with led light<br />
MD Plug-in wire assembly led light & ground wire<br />
ME Plug-in wire assembly with suppression diode<br />
MF Plug-in wire assembly with suppression diode & ground wire<br />
*MG Plug-in wire assembly suppression diode plus led light<br />
*MH Plug-in wire assembly suppression diode plus led light & ground wire<br />
*MN Plug-in wire assembly with suppression diode plus blocking diode<br />
*MP Plug-in wire assembly with suppression diode plus blocking diode & ground wire<br />
MR Plug-in wire assembly with suppression diode plus blocking diode & led light<br />
MS Plug-in wire assembly with suppression diode plus blocking diode & led light & ground wire<br />
MJ Plug-in housing w/o wire assembly (“MA” option without wire assembly)<br />
MM Plug-in housing w/o wire assembly (“MB” option without wire assembly)<br />
* Blocking diode is in lead wire.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
PIN #6<br />
PIN #9<br />
MOD. SD09<br />
PIN #1<br />
PIN #5<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 9<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 7 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 2 common wires<br />
PIN #9<br />
PIN #15<br />
MOD. SD15<br />
PIN #1<br />
PIN #8<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 15<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 12 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 3 common wires<br />
PIN #14<br />
PIN #25<br />
MOD. SD25<br />
PIN #1<br />
PIN #13<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 25<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 20 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 5 common wires<br />
Note : Use desired MOD. number after circuit bar part number
O p t i o n s<br />
OPTIONS<br />
Connector termination details<br />
CONNECTOR<br />
SOL 1<br />
SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />
Single solenoid circuit bar<br />
SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />
CONNECTOR<br />
SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />
Double solenoid circuit bar<br />
SD09 SD15 SD25<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
8<br />
COMMON (+)<br />
13<br />
COMMON (+)<br />
21<br />
COMMON (+)<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
9<br />
COMMON (+)<br />
8<br />
SOL. 8<br />
8<br />
SOL. 8<br />
14<br />
COMMON (+)<br />
22<br />
COMMON (+)<br />
9<br />
SOL. 9<br />
9<br />
SOL. 9<br />
10 SOL. 10<br />
10 SOL. 10<br />
11<br />
SOL. 11<br />
11<br />
SOL. 11<br />
12 SOL. 12<br />
12 SOL. 12<br />
15<br />
COMMON (+)<br />
23<br />
COMMON (+)<br />
13<br />
SOL. 13<br />
14 SOL. 14<br />
15<br />
SOL. 15<br />
16 SOL. 16<br />
24<br />
COMMON (+)<br />
17<br />
18 SOL. 18<br />
19<br />
20 SOL. 20<br />
SOL. 17<br />
SOL. 19<br />
25<br />
COMMON (+)
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Circuit bar mounting<br />
low profile<br />
cylinder ports<br />
in valve<br />
low profile<br />
cylinder ports<br />
in base<br />
mid profile<br />
cylinder ports<br />
in valve<br />
mid profile -<br />
add on style<br />
cylinder ports<br />
in valve<br />
add-a-unit<br />
stations for<br />
CBM403A bar<br />
mid profile<br />
cylinder ports<br />
in base<br />
mid profile -<br />
add on style<br />
cylinder ports<br />
in base<br />
add-a-unit<br />
stations for<br />
CBM404A bar<br />
high profile<br />
cylinder ports<br />
in base<br />
high profile -<br />
add on style<br />
cylinder ports<br />
in base<br />
add-a-unit<br />
stations for<br />
CBM405A bar<br />
Manual operator<br />
Solenoid<br />
4-way pilot with balanced poppet<br />
Bonded spool<br />
2 4<br />
Air return<br />
3<br />
1 5<br />
SERIES FEATURES<br />
• Patented MACSOLENOID ® for fastest possible response times<br />
<strong>and</strong> virtually burn-out proof AC solenoid operation.<br />
• Optional low watt DC solenoids.<br />
• Various manual operators.<br />
• Optional memory spring.<br />
• 2 position or 3 position valve configurations.<br />
• Internal or external pilot.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” - 1/4” 1.0C v<br />
low profile<br />
cylinder ports<br />
in valve<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
1/8” NPT<br />
Internal<br />
315<br />
411A-AOA-DM-DXXX-XXX<br />
411A-COA-DM-DXXX-XXX<br />
315<br />
421A-AOA-DM-DXXX-XXX<br />
315<br />
451A-AOA-DM-DXXX-XXX<br />
315<br />
461A-AOA-DM-DXXX-XXX<br />
315<br />
471A-AOA-DM-DXXX-XXX<br />
1/4” NPT<br />
411A-BOA-DM-DXXX-XXX<br />
421A-BOA-DM-DXXX-XXX<br />
451A-BOA-DM-DXXX-XXX<br />
461A-BOA-DM-DXXX-XXX<br />
471A-BOA-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
JA 120/60, 110/50<br />
JC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
A<br />
J<br />
x<br />
18” (Flying leads)<br />
Connector<br />
Other Options<br />
1 Non-locking<br />
2 Locking<br />
x Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
CBM401A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard 19,5 mm<br />
w/o flow controls<br />
w/ flow controls<br />
Spacing 26 mm (Rectangular connector)<br />
w/o flow controls<br />
w/ flow controls<br />
3/8” NPTF<br />
Internal<br />
CBM401A-00AAA-XX<br />
CBM401A-00BAA-XX<br />
CBM401A-02AAA-XX<br />
CBM401A-02BAA-XX<br />
Number of stations (03=3 stations)<br />
** Other options available. Consult factory.<br />
O P T I O N S<br />
411A-AOA-DM-DXXX-XXX<br />
- clic with memory spring (replace by 4).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Compressed air, vacuum, inert gases<br />
20 - 150 PSI<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.<br />
• Mounting screw (x2) : 35043.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
108.5 94.3<br />
18.5<br />
16.0<br />
C L<br />
14.5<br />
14<br />
14<br />
14<br />
14<br />
3<br />
5 1<br />
12<br />
12<br />
12<br />
12<br />
3 1 5<br />
82.0<br />
118.0 DOUBLE<br />
108.2 SINGLE<br />
41.0<br />
67.5<br />
94.5<br />
7.0<br />
25.0 39.0 19.5<br />
6.7<br />
21.5<br />
32.0<br />
C L<br />
3/8" PORTS<br />
TYP.<br />
É” 6.50 TYP.<br />
1/8" PORTS<br />
TYP.<br />
27.8<br />
31.5<br />
50.7<br />
25.0<br />
64.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” 1.0C v<br />
low profile<br />
cylinder ports<br />
in base<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
Internal<br />
315<br />
413A-OOA-DM-DXXX-XXX<br />
315<br />
423A-OOA-DM-DXXX-XXX<br />
315<br />
453A-OOA-DM-DXXX-XXX<br />
315<br />
463A-OOA-DM-DXXX-XXX<br />
315<br />
473A-OOA-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
JA 120/60, 110/50<br />
JC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
A<br />
J<br />
x<br />
18” (Flying leads)<br />
Connector<br />
Other Options<br />
1 Non-locking<br />
2 Locking<br />
x Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) **<br />
CBM402A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard 19,5 mm<br />
w/o flow controls<br />
w/ flow controls<br />
Spacing 26 mm (Rectangular connector)<br />
w/o flow controls<br />
w/ flow controls<br />
1/8” NPTF<br />
Internal<br />
CBM402A-00AAA-XX<br />
CBM402A-00BAA-XX<br />
CBM402A-02AAA-XX<br />
CBM402A-02BAA-XX<br />
Number of stations (03=3 stations)<br />
** Other options available. Consult factory.<br />
O P T I O N S<br />
413A-OOA-DM-DXXX-XXX<br />
- clic with memory spring (replace by 6).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Compressed air, vacuum, inert gases<br />
20 - 150 PSI<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.<br />
• Mounting screw (x2) : 35043.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
108.5 94.3<br />
18.5<br />
16.0<br />
C L<br />
14.5<br />
14<br />
14<br />
14<br />
14<br />
3<br />
5 1<br />
12<br />
12<br />
12<br />
12<br />
3 1 5<br />
82.0<br />
118.0 DOUBLE<br />
108.2 SINGLE<br />
41.0<br />
67.5<br />
94.5<br />
7.0<br />
6.7<br />
21.5<br />
32.0<br />
C L<br />
3/8" PORTS<br />
TYP.<br />
Ø 6.50 TYP.<br />
1/8" PORTS<br />
TYP.<br />
27.8<br />
31.5<br />
50.7<br />
25.0<br />
64.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” - 1/4” 1.0C v<br />
mid profile<br />
cylinder ports<br />
in valve<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
1/8” NPT<br />
Internal<br />
315<br />
411A-AOA-DM-DXXX-XXX<br />
411A-COA-DM-DXXX-XXX<br />
315<br />
421A-AOA-DM-DXXX-XXX<br />
315<br />
451A-AOA-DM-DXXX-XXX<br />
315<br />
461A-AOA-DM-DXXX-XXX<br />
315<br />
471A-AOA-DM-DXXX-XXX<br />
1/4” NPT<br />
411A-BOA-DM-DXXX-XXX<br />
421A-BOA-DM-DXXX-XXX<br />
451A-BOA-DM-DXXX-XXX<br />
461A-BOA-DM-DXXX-XXX<br />
471A-BOA-DM-DXXX-XXX<br />
1/8” NPT<br />
External<br />
411A-AOD-DM-DXXX-XXX<br />
421A-AOD-DM-DXXX-XXX<br />
451A-AOD-DM-DXXX-XXX<br />
461A-AOD-DM-DXXX-XXX<br />
471A-AOD-DM-DXXX-XXX<br />
1/4” NPT<br />
411A-BOD-DM-DXXX-XXX<br />
421A-BOD-DM-DXXX-XXX<br />
451A-BOD-DM-DXXX-XXX<br />
461A-BOD-DM-DXXX-XXX<br />
471A-BOD-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
JA 120/60, 110/50<br />
JC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
A<br />
J<br />
x<br />
18” (Flying leads)<br />
Connector<br />
Other Options<br />
1 Non-locking<br />
2 Locking<br />
x<br />
Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
CBM403A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard 19,5 mm<br />
w/o flow controls<br />
w/ flow controls<br />
Spacing 26 mm (Rectangular connector)<br />
w/o flow controls<br />
w/ flow controls<br />
3/8” NPTF<br />
Internal<br />
CBM403A-00AAA-XX<br />
CBM403A-00BAA-XX<br />
CBM403A-02AAA-XX<br />
CBM403A-02BAA-XX<br />
Common external<br />
CBM403A-00CAA-XX<br />
CBM403A-00DAA-XX<br />
CBM403A-02CAA-XX<br />
CBM403A-02DAA-XX<br />
Number of stations (03=3 stations)<br />
** Other options available. Consult factory.<br />
O P T I O N S<br />
411A-AOA-DM-DXXX-XXX<br />
- clic with memory spring (replace by 4).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum - 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.<br />
• Mounting screw (x2) : 35043.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
32,0<br />
125,0 DOUBLE (45)<br />
96,0 SINGLE (45)<br />
27,75<br />
5 1 3<br />
7,0<br />
C L<br />
4 2<br />
19,5<br />
69,5<br />
100,3<br />
C L<br />
4 2<br />
25,0<br />
5 1 3<br />
26,5<br />
21,0<br />
8,0<br />
15,0 20,5<br />
24,5<br />
38,0<br />
Ø 6,5<br />
3/8"<br />
67,5<br />
32,0<br />
41,0<br />
14,5<br />
1/8” EXTERNAL<br />
PILOT PORT<br />
(OPTIONAL)<br />
82,0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” - 1/4” 1.0C v<br />
add on style<br />
cylinder ports<br />
mid profile -<br />
in valve<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
1/8” NPT<br />
Internal<br />
315<br />
411A-AOA-DM-DXXX-XXX<br />
411A-COA-DM-DXXX-XXX<br />
315<br />
421A-AOA-DM-DXXX-XXX<br />
315<br />
451A-AOA-DM-DXXX-XXX<br />
315<br />
461A-AOA-DM-DXXX-XXX<br />
315<br />
471A-AOA-DM-DXXX-XXX<br />
1/4” NPT<br />
411A-BOA-DM-DXXX-XXX<br />
421A-BOA-DM-DXXX-XXX<br />
451A-BOA-DM-DXXX-XXX<br />
461A-BOA-DM-DXXX-XXX<br />
471A-BOA-DM-DXXX-XXX<br />
1/8” NPT<br />
External<br />
411A-AOD-DM-DXXX-XXX<br />
421A-AOD-DM-DXXX-XXX<br />
451A-AOD-DM-DXXX-XXX<br />
461A-AOD-DM-DXXX-XXX<br />
471A-AOD-DM-DXXX-XXX<br />
1/4” NPT<br />
411A-BOD-DM-DXXX-XXX<br />
421A-BOD-DM-DXXX-XXX<br />
451A-BOD-DM-DXXX-XXX<br />
461A-BOD-DM-DXXX-XXX<br />
471A-BOD-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
JA 120/60, 110/50<br />
JC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
A<br />
J<br />
x<br />
18” (Flying leads)<br />
Connector<br />
Other Options<br />
1 Non-locking<br />
2 Locking<br />
x<br />
Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
CBM403A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard 19,5 mm<br />
w/o flow controls<br />
w/ flow controls<br />
Spacing 26 mm (Rectangular connector)<br />
w/o flow controls<br />
w/ flow controls<br />
3/8” NPTF<br />
Internal<br />
CBM403A-00ABA-XX<br />
CBM403A-00BBA-XX<br />
CBM403A-02ABA-XX<br />
CBM403A-02BBA-XX<br />
Common external<br />
CBM403A-00CBA-XX<br />
CBM403A-00DBA-XX<br />
CBM403A-02CBA-XX<br />
CBM403A-02DBA-XX<br />
Number of stations (03=3 stations)<br />
** Other options available. Consult factory.<br />
Note: add-a-unit stations may be added to above bars.<br />
O P T I O N S<br />
411A-AOA-DM-DXXX-XXX<br />
- clic with memory spring (replace by 4).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
4<br />
2<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum - 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.<br />
• Mounting screw (x2) : 35043. • End plate kit : M-04003-01. • End plate kit for common external : M-04004-01.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
113.0 99.0<br />
100.3<br />
24.5<br />
Ø 6.5 TYP.<br />
21.0<br />
C L<br />
C L<br />
15.0<br />
7.0<br />
5 1 3<br />
14<br />
12<br />
14<br />
4 2<br />
12<br />
14<br />
4 2<br />
12<br />
14<br />
4 2<br />
12<br />
3<br />
1 5<br />
117.5 DOUBLE<br />
32.0<br />
82.0<br />
107.9 SINGLE<br />
18.0<br />
14.5<br />
32.0<br />
41.0<br />
67.5<br />
27.8<br />
1/8" EXTERNAL<br />
PILOT PORT<br />
25.0<br />
19.5<br />
6.5<br />
8.0<br />
OPTIONAL<br />
55.0<br />
40.5<br />
21.0<br />
16.0<br />
1/8" PORTS<br />
TYP. 8 PLACES<br />
3/8" PORTS<br />
TYP.<br />
20.5<br />
380<br />
C L<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” - 1/4” 1.0C v<br />
add-a-unit<br />
stations for<br />
CBM403A bar<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
1/8” NPT<br />
Internal<br />
315<br />
411A-AOA-DM-DXXX-XXX<br />
411A-COA-DM-DXXX-XXX<br />
315<br />
421A-AOA-DM-DXXX-XXX<br />
315<br />
451A-AOA-DM-DXXX-XXX<br />
315<br />
461A-AOA-DM-DXXX-XXX<br />
315<br />
471A-AOA-DM-DXXX-XXX<br />
1/4” NPT<br />
411A-BOA-DM-DXXX-XXX<br />
421A-BOA-DM-DXXX-XXX<br />
451A-BOA-DM-DXXX-XXX<br />
461A-BOA-DM-DXXX-XXX<br />
471A-BOA-DM-DXXX-XXX<br />
1/8” NPT<br />
External<br />
411A-AOD-DM-DXXX-XXX<br />
421A-AOD-DM-DXXX-XXX<br />
451A-AOD-DM-DXXX-XXX<br />
461A-AOD-DM-DXXX-XXX<br />
471A-AOD-DM-DXXX-XXX<br />
1/4” NPT<br />
411A-BOD-DM-DXXX-XXX<br />
421A-BOD-DM-DXXX-XXX<br />
451A-BOD-DM-DXXX-XXX<br />
461A-BOD-DM-DXXX-XXX<br />
471A-BOD-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
JA 120/60, 110/50<br />
JC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR **<br />
A<br />
J<br />
x<br />
18” (Flying leads)<br />
Connector<br />
Other Options<br />
1 Non-locking<br />
2 Locking<br />
x<br />
Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
CBM403A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing 21 mm<br />
w/o flow controls<br />
w/ flow controls<br />
Spacing 26 mm (Rectangular connector)<br />
w/o flow controls<br />
w/ flow controls<br />
3/8” NPTF<br />
Internal<br />
CBM403A-01AEA-XX<br />
CBM403A-01BEA-XX<br />
CBM403A-02AEA-XX<br />
CBM403A-02BEA-XX<br />
Common external<br />
CBM403A-01CEA-XX<br />
CBM403A-01DEA-XX<br />
CBM403A-02CEA-XX<br />
CBM403A-02DEA-XX<br />
Number of stations (01, 02, 03, or 04)<br />
** Other options available. Consult factory.<br />
O P T I O N S<br />
411A-AOA-DM-DXXX-XXX<br />
- clic with memory spring (replace by 4).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
4<br />
2<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum - 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.<br />
• Mounting screw (x2) : 35043. • End plate kit : M-04003-01. • End plate kit for common external : M-04004-01.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
113.0 99.0<br />
100.3<br />
24.5<br />
Ø 6.5 TYP.<br />
21.0<br />
C L<br />
C L<br />
15.0<br />
7.0<br />
5 1 3<br />
14<br />
12<br />
14<br />
4 2<br />
12<br />
14<br />
4 2<br />
12<br />
14<br />
4 2<br />
12<br />
3<br />
1 5<br />
117.5 DOUBLE<br />
32.0<br />
82.0<br />
107.9 SINGLE<br />
18.0<br />
14.5<br />
32.0<br />
41.0<br />
67.5<br />
27.8<br />
1/8" EXTERNAL<br />
PILOT PORT<br />
25.0<br />
19.5<br />
6.5<br />
8.0<br />
OPTIONAL<br />
55.0<br />
40.5<br />
21.0<br />
16.0<br />
1/8" PORTS<br />
TYP. 8 PLACES<br />
3/8" PORTS<br />
TYP.<br />
20.5<br />
380<br />
C L<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” - 1/4” 1.0C v<br />
mid profile<br />
cylinder ports<br />
in base<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
Internal<br />
315<br />
413A-OOA-DM-DXXX-XXX<br />
315<br />
423A-OOA-DM-DXXX-XXX<br />
315<br />
453A-OOA-DM-DXXX-XXX<br />
315<br />
463A-OOA-DM-DXXX-XXX<br />
315<br />
473A-OOA-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
A 18” (Flying leads)<br />
JA 120/60, 110/50<br />
J Connector<br />
JC 24/60, 24/50<br />
x Other Options<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) **<br />
1 Non-locking<br />
2 Locking<br />
x<br />
Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
CBM404A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard 19,5 mm<br />
w/o flow controls<br />
w/ flow controls<br />
Spacing 26 mm (Rectangular connector)<br />
w/o flow controls<br />
w/ flow controls<br />
1/8” NPTF<br />
1/4” NPTF<br />
Internal<br />
Internal<br />
CBM404A-00AAA-XX<br />
CBM404A-00AAD-XX<br />
CBM404A-00BAA-XX<br />
CBM404A-00BAD-XX<br />
CBM404A-02AAA-XX<br />
CBM404A-02AAD-XX<br />
CBM404A-02BAA-XX<br />
CBM404A-02BAD-XX<br />
Number of stations (03=3 stations)<br />
** Other options available. Consult factory.<br />
O P T I O N S<br />
413A-OOA-DM-DXXX-XXX<br />
- clic with memory spring (replace by 6).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Compressed air, vacuum, inert gases<br />
20 - 150 PSI<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.<br />
• Mounting screw (x2) : 35043.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
32,0<br />
125,0 DOUBLE (45)<br />
96,0 SINGLE (45)<br />
27,8<br />
100,3<br />
C L<br />
5 1 3<br />
4 2<br />
7,0<br />
C L<br />
4 2<br />
19,5<br />
69,5<br />
25,0<br />
5 1 3<br />
26,5<br />
21,0<br />
15,0 20,5<br />
24,5<br />
38,0<br />
3/8 " PORTS<br />
4 2<br />
14,5<br />
B A<br />
41,0<br />
67,5<br />
82,0<br />
Port size<br />
A<br />
B<br />
1/8”<br />
1/4”<br />
31.5<br />
32.0<br />
19.0<br />
20.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” - 1/4” 1.0C v<br />
add on style<br />
cylinder ports<br />
mid profile -<br />
in base<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
Internal<br />
315<br />
413A-OOA-DM-DXXX-XXX<br />
315<br />
423A-OOA-DM-DXXX-XXX<br />
315<br />
453A-OOA-DM-DXXX-XXX<br />
315<br />
463A-OOA-DM-DXXX-XXX<br />
315<br />
473A-OOA-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
A 18” (Flying leads)<br />
JA 120/60, 110/50<br />
J Connector<br />
JC 24/60, 24/50<br />
x Other Options<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) **<br />
1 Non-locking<br />
2 Locking<br />
x<br />
Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
CBM404A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard 19,5 mm<br />
w/o flow controls<br />
w/ flow controls<br />
Spacing 26 mm (Rectangular connector)<br />
w/o flow controls<br />
w/ flow controls<br />
1/8” NPTF<br />
1/4” NPTF<br />
Internal<br />
Internal<br />
CBM404A-00ABA-XX<br />
CBM404A-00ABD-XX<br />
CBM404A-00BBA-XX<br />
CBM404A-00BBD-XX<br />
CBM404A-02ABA-XX<br />
CBM404A-02ABD-XX<br />
CBM404A-02BBA-XX<br />
CBM404A-02BBD-XX<br />
Number of stations (03=3 stations)<br />
** Other options available. Consult factory.<br />
Note: add-a-unit stations may be added to above bars.<br />
O P T I O N S<br />
413A-OOA-DM-DXXX-XXX<br />
- clic with memory spring, replace by 6.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Compressed air, vacuum, inert gases<br />
20 - 150 PSI<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.<br />
• Mounting screw (x2) : 35043. • End plate kit : M-04003-01.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
113.0<br />
100.3<br />
É” 6.5 TYP.<br />
24.5<br />
21.0<br />
15.0<br />
5 1 3<br />
14<br />
12<br />
14<br />
12<br />
14<br />
12<br />
CL<br />
14<br />
12<br />
CL LC<br />
3<br />
1<br />
5<br />
82.0<br />
117.5 DOUBLE<br />
107.9 SINGLE<br />
14.5<br />
32.0<br />
41.0<br />
67.5<br />
99.0<br />
7.0<br />
25.0<br />
19.5<br />
6.5<br />
8.0<br />
1/8" EXTERNAL<br />
PILOT PORT<br />
OPTIONAL<br />
2<br />
2<br />
2<br />
2<br />
27.8<br />
31.5<br />
50.5<br />
40.5<br />
3/8" PORTS<br />
TYP.<br />
4<br />
4<br />
4<br />
4<br />
1/8" PORTS<br />
55.0 21.0<br />
16.0<br />
TYP. 8 PLACES<br />
20.5<br />
38.0<br />
42.0<br />
26.5<br />
C L<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” - 1/4” 1.0C v<br />
add-a-unit<br />
stations for<br />
CBM404A bar<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
Internal<br />
315<br />
413A-OOA-DM-DXXX-XXX<br />
315<br />
423A-OOA-DM-DXXX-XXX<br />
315<br />
453A-OOA-DM-DXXX-XXX<br />
315<br />
463A-OOA-DM-DXXX-XXX<br />
315<br />
473A-OOA-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
A 18” (Flying leads)<br />
JA 120/60, 110/50<br />
J Connector<br />
JC 24/60, 24/50<br />
x Other Options<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) **<br />
1 Non-locking<br />
2 Locking<br />
x<br />
Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
CBM404A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing 21 mm<br />
w/o flow controls<br />
w/ flow controls<br />
Spacing 26 mm (Rectangular connector)<br />
w/o flow controls<br />
w/ flow controls<br />
1/8” NPTF<br />
1/4” NPTF<br />
Internal<br />
Internal<br />
CBM404A-01AEA-XX<br />
CBM404A-01AED-XX<br />
CBM404A-01BEA-XX<br />
CBM404A-01BED-XX<br />
CBM404A-02AEA-XX<br />
CBM404A-02AED-XX<br />
CBM404A-02BEA-XX<br />
CBM404A-02BED-XX<br />
Number of stations (01, 02, 03, or 04)<br />
** Other options available. Consult factory.<br />
O P T I O N S<br />
413A-OOA-DM-DXXX-XXX<br />
- clic with memory spring (replace by 6).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Compressed air, vacuum, inert gases<br />
20 - 150 PSI<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.<br />
• Mounting screw (x2) : 35043. • End plate kit : M-04003-01.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
113.0<br />
100.3<br />
É” 6.5 TYP.<br />
24.5<br />
21.0<br />
15.0<br />
5 1 3<br />
14<br />
12<br />
14<br />
12<br />
14<br />
12<br />
CL<br />
14<br />
12<br />
CL LC<br />
3<br />
1<br />
5<br />
82.0<br />
117.5 DOUBLE<br />
107.9 SINGLE<br />
14.5<br />
32.0<br />
41.0<br />
67.5<br />
99.0<br />
7.0<br />
25.0<br />
19.5<br />
6.5<br />
8.0<br />
1/8" EXTERNAL<br />
PILOT PORT<br />
OPTIONAL<br />
2<br />
2<br />
2<br />
2<br />
27.8<br />
31.5<br />
50.5<br />
40.5<br />
3/8" PORTS<br />
TYP.<br />
4<br />
4<br />
4<br />
4<br />
1/8" PORTS<br />
55.0 21.0<br />
16.0<br />
TYP. 8 PLACES<br />
20.5<br />
38.0<br />
42.0<br />
26.5<br />
C L<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” - 1/4” 1.0C v<br />
high profile<br />
cylinder ports<br />
in base<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
Internal<br />
315<br />
413A-OOA-DM-DXXX-XXX<br />
315<br />
423A-OOA-DM-DXXX-XXX<br />
315<br />
453A-OOA-DM-DXXX-XXX<br />
315<br />
463A-OOA-DM-DXXX-XXX<br />
315<br />
473A-OOA-DM-DXXX-XXX<br />
External<br />
413A-OOD-DM-DXXX-XXX<br />
423A-OOD-DM-DXXX-XXX<br />
453A-OOD-DM-DXXX-XXX<br />
463A-OOD-DM-DXXX-XXX<br />
473A-OOD-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
A 18” (Flying leads)<br />
JA 120/60, 110/50<br />
J Connector<br />
JC 24/60, 24/50<br />
x Other Options<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR (SIDE CYLINDER PORTS) **<br />
1 Non-locking<br />
2 Locking<br />
x<br />
Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
CBM405A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard 19,5 mm<br />
Spacing 26 mm<br />
(Rectangular connector)<br />
1/8” NPTF<br />
1/4” NPTF<br />
Internal<br />
Common external<br />
Internal<br />
Common external<br />
CBM405A-00AAA-XX<br />
CBM405A-00BAA-XX<br />
CBM405A-00AAD-XX<br />
CBM405A-00BAD-XX<br />
CBM405A-02AAA-XX<br />
CBM405A-02BAA-XX<br />
CBM405A-02AAD-XX<br />
CBM405A-02BAD-XX<br />
Number of stations (03=3 stations)<br />
** Other options available. Consult factory.<br />
O P T I O N S<br />
413A-OOA-DM-DXXX-XXX<br />
- clic with memory spring (replace by 6).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum - 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04002. • Seal : 16525. • Mounting screw (x2) : 35043.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
5 1 3<br />
7,0<br />
C L<br />
4 2<br />
69,5<br />
4 2<br />
25,0<br />
19,5<br />
5 1 3<br />
59,0<br />
32,0<br />
125,0 DOUBLE (45)<br />
96,0 SINGLE (45)<br />
114,3<br />
2<br />
40,0<br />
33,5<br />
22,0<br />
52,0<br />
19,0<br />
4<br />
9,5<br />
3/8" PORTS<br />
1/8” EXTERNAL<br />
PILOT PORT<br />
(OPTIONAL)<br />
72,0<br />
46,0<br />
35,0<br />
20,0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” - 1/4” 1.0C v<br />
add on style<br />
cylinder ports<br />
high profile -<br />
in base<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
Internal<br />
315<br />
413A-OOA-DM-DXXX-XXX<br />
315<br />
423A-OOA-DM-DXXX-XXX<br />
315<br />
453A-OOA-DM-DXXX-XXX<br />
315<br />
463A-OOA-DM-DXXX-XXX<br />
315<br />
473A-OOA-DM-DXXX-XXX<br />
External<br />
413A-OOD-DM-DXXX-XXX<br />
423A-OOD-DM-DXXX-XXX<br />
453A-OOD-DM-DXXX-XXX<br />
463A-OOD-DM-DXXX-XXX<br />
473A-OOD-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
A 18” (Flying leads)<br />
JA 120/60, 110/50<br />
J Connector<br />
JC 24/60, 24/50<br />
x Other Options<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR (SIDE CYLINDER PORTS) **<br />
1 Non-locking<br />
2 Locking<br />
x<br />
Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
CBM405A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing st<strong>and</strong>ard 19,5 mm<br />
Spacing 26 mm<br />
(Rectangular connector)<br />
1/8” NPTF<br />
1/4” NPTF<br />
Internal<br />
Common external<br />
Internal<br />
Common external<br />
CBM405A-00ABA-XX<br />
CBM405A-00BCA-XX<br />
CBM405A-00ABD-XX<br />
CBM405A-00BCD-XX<br />
CBM405A-02ABA-XX<br />
CBM405A-02BCA-XX<br />
CBM405A-02ABD-XX<br />
CBM405A-02BCD-XX<br />
Number of stations (03=3 stations)<br />
** Other options available. Consult factory.<br />
Note: add-a-unit stations may be added to above bars.<br />
O P T I O N S<br />
413A-OOA-DM-DXXX-XXX<br />
- clic with memory spring (replace by 6).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum - 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04002. • Seal : 16525. • Mounting screw (x2) : 35043.<br />
• End plate kit : M-04005-01. • End plate kit for common external pilot : M-04006-01.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
113.0<br />
114.3<br />
40.0<br />
33.5<br />
19.0<br />
84.0<br />
5 1 3<br />
12<br />
14<br />
12<br />
14<br />
12<br />
14 14<br />
12<br />
3<br />
1<br />
5<br />
118.0 DOUBLE<br />
98.5 SINGLE<br />
20.0<br />
35.0<br />
46.0<br />
72.0<br />
99.0<br />
7.0<br />
1/8" EXTERNAL<br />
PILOT PORT<br />
21.0<br />
21.0<br />
3/8" PORTS<br />
TYP.<br />
OPTIONAL<br />
59.0<br />
10.5<br />
16.0<br />
55.0<br />
9.5<br />
Ø 6.50<br />
TYP 2<br />
16.0<br />
4<br />
2<br />
52.0<br />
20.0<br />
21.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 400<br />
Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/8” - 1/4” 1.0C v<br />
add-a-unit<br />
stations for<br />
CBM405A bar<br />
OPERATIONAL BENEFITS<br />
1. The 4-way pilot develops maximum shifting forces<br />
both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of pressure,<br />
also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />
consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-xxx-DM-Dxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Pilot air<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
2 4<br />
12 14<br />
2 4<br />
12 14<br />
12 2 4 14<br />
12 2 4 14<br />
12 2 4 14<br />
Internal<br />
315<br />
413A-OOA-DM-DXXX-XXX<br />
315<br />
423A-OOA-DM-DXXX-XXX<br />
315<br />
453A-OOA-DM-DXXX-XXX<br />
315<br />
463A-OOA-DM-DXXX-XXX<br />
315<br />
473A-OOA-DM-DXXX-XXX<br />
External<br />
413A-OOD-DM-DXXX-XXX<br />
423A-OOD-DM-DXXX-XXX<br />
453A-OOD-DM-DXXX-XXX<br />
463A-OOD-DM-DXXX-XXX<br />
473A-OOD-DM-DXXX-XXX<br />
SOLENOID OPERATOR ➤<br />
D XX X- X XX *<br />
XX Voltage<br />
X Wire length<br />
X Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
A 18” (Flying leads)<br />
JA 120/60, 110/50<br />
J Connector<br />
JC 24/60, 24/50<br />
x Other Options<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR (SIDE CYLINDER PORTS) **<br />
1 Non-locking<br />
2 Locking<br />
x<br />
Other Options<br />
KA<br />
KD<br />
JB<br />
JD<br />
BA<br />
xx<br />
Square connector<br />
Square connector<br />
with light<br />
Rectangular connector<br />
Rectangular connector<br />
with light<br />
Flying leads<br />
Other Options<br />
CBM405A-xxxxx-xx<br />
Port size<br />
Pilot air<br />
Spacing 21 mm<br />
Spacing 26 mm<br />
(Rectangular connector)<br />
1/8” NPTF<br />
1/4” NPTF<br />
Internal<br />
Common external<br />
Internal<br />
Common external<br />
CBM405A-01AEA-XX<br />
CBM405A-01BEA-XX<br />
CBM405A-01AED-XX<br />
CBM405A-01BED-XX<br />
CBM405A-02AEA-XX<br />
CBM405A-02BEA-XX<br />
CBM405A-02AED-XX<br />
CBM405A-02BED-XX<br />
Number of stations (01, 02, 03, or 04)<br />
** Other options available. Consult factory.<br />
O P T I O N S<br />
413A-OOA-DM-DXXX-XXX<br />
- clic with memory spring (replace by 6).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 400<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Accessories :<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 - 150 PSI<br />
External pilot : vacuum - 150 PSI<br />
20 - 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 10.9 VA Holding : 7.7 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />
• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />
• Blanking plate : M-04002. • Seal : 16525. • Mounting screw (x2) : 35043.<br />
• End plate kit : M-04005-01. • End plate kit for common external pilot : M-04006-01.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />
DIMENSIONS<br />
113.0<br />
114.3<br />
40.0<br />
33.5<br />
19.0<br />
84.0<br />
5 1 3<br />
12<br />
14<br />
12<br />
14<br />
12<br />
14 14<br />
12<br />
3<br />
1<br />
5<br />
118.0 DOUBLE<br />
98.5 SINGLE<br />
20.0<br />
35.0<br />
46.0<br />
72.0<br />
99.0<br />
7.0<br />
1/8" EXTERNAL<br />
PILOT PORT<br />
21.0<br />
21.0<br />
3/8" PORTS<br />
TYP.<br />
OPTIONAL<br />
59.0<br />
10.5<br />
16.0<br />
55.0<br />
9.5<br />
Ø 6.50<br />
TYP 2<br />
16.0<br />
4<br />
2<br />
52.0<br />
20.0<br />
21.0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Section 2 Options<br />
Consult “Precautions” before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Codification table for voltages / Wire length / Manual operator / Electrical connection<br />
VALVE CODE ➤<br />
D M - D XX X - X XX<br />
1 2 3 4<br />
OPTIONS AVAILABLE FOR<br />
- pilot operated valves 400, 52 & 92 Series<br />
Consult “Precautions”before use, installation or service of MAC Valves.
OPTIONS<br />
Back<br />
1. VOLTAGE<br />
- D XX X - X XX VOLTAGE<br />
DB 12 VDC (5.4 W)<br />
DC 12 VDC (7.5 W)<br />
DD 24 VDC (7.3 W)<br />
DE 12 VDC (12.7 W)<br />
DK 110 VDC (5.8 W)<br />
DJ 28 VDC (5.7 W)<br />
DL 64 VDC (6.0 W)<br />
DM 36 VDC (5.8 W)<br />
DN 6 VDC (6.0 W)<br />
DR 90 VDC (6,6 W)<br />
DS 110 VDC (7.3 W), 100 VDC (6.0 W)<br />
DT 75 VDC (5.6 W)<br />
DP 48 VDC (5.8 W)<br />
FA 12 VDC (1.8 W)<br />
FE 12 VDC (2.4 W)<br />
FF 24 VDC (2.4 W)<br />
JD 100/60, 100/50, 110/60<br />
2. WIRE LENGTH<br />
- D XX X - X XX WIRE LENGTH<br />
B 24”<br />
C 36”<br />
D 48”<br />
E 72”<br />
F 96”<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Back<br />
3. MANUAL OPERATOR<br />
- D XX X - X XX MANUAL OPERATOR<br />
0 No operator<br />
1 Non-locking recessed<br />
2 Locking recessed<br />
3 Non-locking extended<br />
4 Locking extended<br />
4. ELECTRICAL CONNECTION<br />
- D XX X - X XX ELECTRICAL CONNECTION<br />
BA Flying leads<br />
BK BA with protection diode<br />
BL BA with protection varistor<br />
CA 1/2" NPS conduit<br />
JB Rectangular connector<br />
JD Rectangular connector with light<br />
JM Rectangular connector, male only<br />
KA Square connector<br />
KB Square connector with protection diode<br />
KC Square connector with protection varistor<br />
KD Square connector with light<br />
KE Square connector with light <strong>and</strong> protection diode<br />
KF Square connector with light <strong>and</strong> protection varistor<br />
KJ Square connector (male only)<br />
KK Square connector with protection diode (male only)<br />
KL Square connector with protection varistor (male only)<br />
TA Dual tabs<br />
TB TA with protection diode<br />
TD TA with light<br />
TE TA with light <strong>and</strong> protection diode<br />
TJ Dual tabs (male only)<br />
TK TJ with protection diode<br />
TM TJ with light<br />
TN TJ with light <strong>and</strong> protection diode<br />
*DN Plug-in with diode<br />
*DP Plug-in with M.O.V.<br />
*DH Plug-in with diode & ground<br />
*DJ Plug-in with M.O.V & ground<br />
* These options only apply to the 92 series. All others are for the 400 <strong>and</strong> 52 series.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
PIN #6<br />
PIN #9<br />
MOD. SD09<br />
PIN #1<br />
PIN #5<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 9<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 7 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 2 common wires<br />
PIN #9<br />
PIN #15<br />
MOD. SD15<br />
PIN #1<br />
PIN #8<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 15<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 12 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 3 common wires<br />
PIN #14<br />
PIN #25<br />
MOD. SD25<br />
PIN #1<br />
PIN #13<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 25<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 20 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 5 common wires<br />
Note : Use desired MOD. number after circuit bar part number
O p t i o n s<br />
OPTIONS<br />
Connector termination details<br />
CONNECTOR<br />
SOL 1<br />
SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />
Single solenoid circuit bar<br />
SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />
CONNECTOR<br />
SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />
Double solenoid circuit bar<br />
SD09 SD15 SD25<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
8<br />
COMMON (+)<br />
13<br />
COMMON (+)<br />
21<br />
COMMON (+)<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
9<br />
COMMON (+)<br />
8<br />
SOL. 8<br />
8<br />
SOL. 8<br />
14<br />
COMMON (+)<br />
22<br />
COMMON (+)<br />
9<br />
SOL. 9<br />
9<br />
SOL. 9<br />
10 SOL. 10<br />
10 SOL. 10<br />
11<br />
SOL. 11<br />
11<br />
SOL. 11<br />
12 SOL. 12<br />
12 SOL. 12<br />
15<br />
COMMON (+)<br />
23<br />
COMMON (+)<br />
13<br />
SOL. 13<br />
14 SOL. 14<br />
15<br />
SOL. 15<br />
16 SOL. 16<br />
24<br />
COMMON (+)<br />
17<br />
18 SOL. 18<br />
19<br />
20 SOL. 20<br />
SOL. 17<br />
SOL. 19<br />
25<br />
COMMON (+)
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 92<br />
Circuit bar mounting<br />
st<strong>and</strong>ard<br />
add-on style<br />
add-a-unit<br />
stations<br />
for CBM092B<br />
Optional light<br />
Plug-in solenoid<br />
Manual operator<br />
Solenoid<br />
Bonded spool<br />
Air return<br />
EXH.<br />
B<br />
IN.<br />
A<br />
EXH.<br />
EXH.<br />
IN.<br />
4-way pilot with balanced poppet<br />
SERIES FEATURES<br />
• Patented MACSOLENOID ® for fastest possible response times<br />
<strong>and</strong> virtually burn-out proof AC solenoid operation.<br />
• Optional low watt DC solenoids.<br />
• Optional memory spring.<br />
• Plug-in design of valves <strong>and</strong> bases for ease of maintenance.<br />
• 2 position or 3 position valve configurations.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves with multi-pin connector<br />
Series 92<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 - 3/2 1/8 - 1/4 - 3/8 1.0C v st<strong>and</strong>ard<br />
OPERATIONAL BENEFITS<br />
1. The 4--way pilot develops maximum shifting<br />
forces both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of<br />
pressure, also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded seal spool with minimum friction,<br />
shifting in a glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short<br />
<strong>and</strong> consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
SINGLE PRESSURE MODELS<br />
92B-xxx-000-DM-DxxP-xxx<br />
Port size<br />
(see circuit bar)<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
Valve less base<br />
92B-AAA-000-DM-DXXP-XXX<br />
92B-BAA-000-DM-DXXP-XXX<br />
92B-EAA-000-DM-DXXP-XXX<br />
92B-FAA-000-DM-DXXP-XXX<br />
92B-GAA-000-DM-DXXP-XXX<br />
DUAL PRESSURE MODELS (REQUIRES SANDWICH PRESSURE REGULATOR)<br />
Port size<br />
(see circuit bar)<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
Valve less base<br />
92B-CAA-000-DM-DXXP-XXX<br />
92B-DAA-000-DM-DXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
DM-DXX P- X XX *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
JA 120/60, 110/50<br />
JC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
1 Non-locking<br />
2 Locking<br />
xx Other Options<br />
DM<br />
DG<br />
Plug-in<br />
Plug-in w/ground<br />
Note : Ground wire required for solenoids 30 volts<br />
<strong>and</strong> above.<br />
xx Other Options<br />
CBM092B-01xxx-AOxx<br />
Port size<br />
Pilot air<br />
Side cylinder ports<br />
(25 mm)<br />
Bottom cylinder ports<br />
(25 mm)<br />
1/8 NPTF<br />
Internal<br />
CBM092B-01AAA-A0*XX<br />
CBM092B-01BAA-A0*XX<br />
Common external<br />
CBM092B-01CAA-A0*XX<br />
CBM092B-01DAA-A0*XX<br />
1/4 NPTF<br />
Internal<br />
CBM092B-01AAD-A0*XX<br />
CBM092B-01BAD-A0*XX<br />
Common external<br />
CBM092B-01CAD-A0*XX<br />
CBM092B-01DAD-A0*XX<br />
3/8 NPTF<br />
Internal<br />
CBM092B-01AAG-A0*XX<br />
CBM092B-01BAG-A0*XX<br />
Common external<br />
CBM092B-01CAG-A0*XX<br />
CBM092B-01DAG-A0*XX<br />
Number of stations (03=3 stations)<br />
* If replaced by BO : circuit bar for single operator valves only.<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
for multi-pin connector (9, 15 or 25).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 92<br />
O P T I O N S<br />
S<strong>and</strong>wich flow controls available, consult factory.<br />
92B-AAA-000-DM-DXXP-1DM<br />
T E C H N I C A L<br />
D A T A<br />
For lights on valve, replace by B.<br />
For lights <strong>and</strong> diode on valve, replace by F.<br />
For lights <strong>and</strong> MOV on valve, replace by H.<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 to 120 PSI<br />
3 positions : 35 to 120 PSI<br />
External pilot : vacuum to 120 PSI<br />
3 positions : 35 to 120 PSI<br />
20 to 120 PSI 3 positions : 35 to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 7.6 VA Holding : 4.8 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 8 ms De-energize : 7 ms<br />
60Hz/2.9 W Energize : 7-13 ms De-energize : 12-20 ms<br />
• Pilot valve : DMB-DXXP-XXX-1 including mounting screws 35069 (x2) <strong>and</strong> seal 16544.<br />
• Pressure seal between valve <strong>and</strong> base : 16543. • Mounting screws valve to base (x2) : 35050. • Blanking plate : M-92002.<br />
Options :<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust. • Circuit bar for number of stations > 24.<br />
DIMENSIONS<br />
C<br />
34.0 D<br />
118.7<br />
B 25.0<br />
TYP.<br />
A 25.0<br />
18.4<br />
TYP.<br />
B B B EXT.P<br />
A A A<br />
A<br />
B<br />
1/8",1/4",3/8",PORTS<br />
AVAILABE ON SIDE<br />
OR BOTTOM<br />
164.3<br />
APROX.<br />
W/DOUBLE<br />
SIOLENOID<br />
148.3<br />
APROX.<br />
W/ SINGLE<br />
SOLENOID<br />
MODEL<br />
A<br />
B<br />
MODEL<br />
A<br />
B<br />
MODEL<br />
A<br />
B<br />
MODEL<br />
A<br />
7.0<br />
TYP.<br />
B<br />
5.5<br />
TYP.<br />
81.5<br />
TYP.<br />
1/8" PORTS EXTERNAL<br />
PILOT PORT 3 PLACES<br />
52.0<br />
42.0<br />
36.5<br />
25.5<br />
21.5<br />
EXT.P<br />
EA<br />
IN<br />
EB<br />
25.5<br />
3/8" PORTS<br />
3 PLACES<br />
BOTH ENDS<br />
27.0<br />
51.2<br />
73.1<br />
115.5<br />
B<br />
COND.<br />
25.0 G<br />
TYP.<br />
1 1/4" N.P.S.M.<br />
CONDUIT BOTH<br />
ENDS<br />
25.6<br />
6.3 DIA. MT'G<br />
HOLES 4 PLACES<br />
B<br />
A<br />
B<br />
A<br />
A<br />
B<br />
A<br />
B<br />
40.4<br />
F<br />
Number of<br />
stations<br />
“H”<br />
1<br />
60.0<br />
2<br />
85.0<br />
3<br />
4<br />
5<br />
6<br />
110.0 135.0 160.0 185.0 210.0 235.0 260.0 285.0<br />
7<br />
8<br />
9<br />
10<br />
Dim.<br />
“A”<br />
“B”<br />
“C”<br />
“D”<br />
1/8”<br />
30.0<br />
39.0<br />
10.0<br />
33.0<br />
1/4”<br />
30.0<br />
39.0<br />
10.0<br />
33.0<br />
3/8”<br />
32.5<br />
36.5<br />
11.0<br />
34.0<br />
25.0 E<br />
TYP.<br />
H<br />
Dimensions are based on 25 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
“E”<br />
“F”<br />
“G”<br />
40.9<br />
61.1<br />
30.1<br />
36.9<br />
61.1<br />
30.9<br />
35.5<br />
62.6<br />
30.7<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves with multi-pin connector<br />
Series 92<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 - 3/2 1/8 - 1/4 - 3/8 1.0C v add-on style<br />
OPERATIONAL BENEFITS<br />
1. The 4--way pilot develops maximum shifting<br />
forces both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of<br />
pressure, also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded seal spool with minimum friction,<br />
shifting in a glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short<br />
<strong>and</strong> consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
SINGLE PRESSURE MODELS<br />
92B-xxx-000-DM-DxxP-xxx<br />
Port size<br />
(see circuit bar)<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
Valve less base<br />
92B-AAA-000-DM-DXXP-XXX<br />
92B-BAA-000-DM-DXXP-XXX<br />
92B-EAA-000-DM-DXXP-XXX<br />
92B-FAA-000-DM-DXXP-XXX<br />
92B-GAA-000-DM-DXXP-XXX<br />
DUAL PRESSURE MODELS (REQUIRES SANDWICH PRESSURE REGULATOR)<br />
Port size<br />
(see circuit bar)<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
Valve less base<br />
92B-CAA-000-DM-DXXP-XXX<br />
92B-DAA-000-DM-DXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
DM-DXX P- X XX *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
JA 120/60, 110/50<br />
JC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
1 Non-locking<br />
2 Locking<br />
xx Other Options<br />
DM<br />
DG<br />
Plug-in<br />
Plug-in w/ground<br />
Note : Ground wire required for solenoids 30 volts<br />
<strong>and</strong> above.<br />
xx Other Options<br />
CBM092B-01xxx-AOxx<br />
Port size<br />
Pilot air<br />
Side cylinder ports<br />
(25 mm)<br />
Bottom cylinder ports<br />
(25 mm)<br />
1/8 NPTF<br />
Internal<br />
CBM092B-01ABA-A0*XX<br />
CBM092B-01BBA-A0*XX<br />
Common external<br />
CBM092B-01CBA-A0*XX<br />
CBM092B-01DBA-A0*XX<br />
1/4 NPTF<br />
Internal<br />
CBM092B-01ABD-A0*XX<br />
CBM092B-01BBD-A0*XX<br />
Common external<br />
CBM092B-01CBD-A0*XX<br />
CBM092B-01DBD-A0*XX<br />
3/8 NPTF<br />
Internal<br />
CBM092B-01ABG-A0*XX<br />
CBM092B-01BBG-A0*XX<br />
Common external<br />
CBM092B-01CBG-A0*XX<br />
CBM092B-01DBG-A0*XX<br />
* If replaced by BO : circuit bar for single operator valves only.<br />
Number of stations (03=3 stations)<br />
Note : add-a-unit stations may be added to above bars. See<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
page for model numbers<br />
for multi-pin connector (9, 15 or 25).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
GAGE<br />
EA<br />
IN<br />
EB<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 92<br />
O P T I O N S<br />
S<strong>and</strong>wich flow controls available, consult factory.<br />
92B-AAA-000-DM-DXXP-1DM<br />
For lights on valve, replace by B.<br />
For lights <strong>and</strong> diode on valve, replace by F.<br />
For lights <strong>and</strong> MOV on valve, replace by H.<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Options :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 to 120 PSI<br />
3 positions : 35 to 120 PSI<br />
External pilot : vacuum to 120 PSI<br />
3 positions : 35 to 120 PSI<br />
20 to 120 PSI 3 positions : 35 to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 7.6 VA Holding : 4.8 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 8 ms De-energize : 7 ms<br />
60Hz/2.9 W Energize : 7-13 ms De-energize : 12-20 ms<br />
• Pilot valve : DMB-DXXP-XXX-1 including mounting screws 35069 (x2) <strong>and</strong> seal 16544.<br />
• Pressure seal between valve <strong>and</strong> base : 16543. • Mounting screws valve to base (x2) : 35050. • Blanking plate : M-92002.<br />
• End plate kit : M-92001-01 • Isolator disc between add-a-units : 28413.<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust. • Circuit bar for number of stations > 24.<br />
DIMENSIONS<br />
EA<br />
EB IN<br />
164.0<br />
APPROX.<br />
W/SINGLE<br />
REGULATOR<br />
192.3<br />
APPROX.<br />
SINGLE REG.<br />
W/ DOUBLE<br />
REGULATOR<br />
241.0<br />
APPROX.<br />
W/DOUBLE<br />
REGULATOR<br />
34.0<br />
137.0 118.7<br />
APPROX.<br />
W/ FLOW<br />
CONTROLS<br />
D<br />
B<br />
A<br />
18.4<br />
C<br />
A<br />
EXT.P<br />
25.0<br />
TYP.<br />
25.0<br />
TYP.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
15.0<br />
B<br />
60.5<br />
APPROX.<br />
FROM C L OF<br />
FLOW CONTROL<br />
1/8",1/4",3/8",<br />
PORTS AVAILABE ON<br />
SIDE OR BOTTOM<br />
70.0<br />
APPROX.<br />
FROM C L OF<br />
REGULATOR<br />
Number of<br />
stations<br />
“H”<br />
1<br />
63.0<br />
2<br />
3<br />
Dimensions are based on 25 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
4<br />
5<br />
6<br />
88.0 113.0 138.0 163.0 188.0 213.0 238.0 263.0 288.0<br />
7<br />
8<br />
9<br />
10<br />
MODEL<br />
157.5<br />
APPROX.<br />
W/ REGULATOR<br />
25.0<br />
7.0<br />
TYP.<br />
E<br />
G<br />
25.0<br />
TYP.<br />
25.0<br />
TYP.<br />
1/8" EXTERNAL PILOT<br />
PORT 3 PLACES<br />
52.0<br />
42.0<br />
36.5<br />
25.5<br />
21.5<br />
27.0<br />
162.6<br />
APPROX.<br />
W/DOUBLE<br />
SOLENOID<br />
148.3<br />
APPROX.<br />
W/ SINGLE<br />
SOLENOID<br />
5.5<br />
TYP.<br />
81.5<br />
TYP.<br />
F<br />
40.4<br />
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
MODIF.<br />
EXT.P<br />
COND<br />
25.5<br />
51.2<br />
73.1<br />
3/8" PORTS<br />
3 HOLES<br />
BOTH ENDS<br />
115.5<br />
Dim.<br />
“A”<br />
“B”<br />
“C”<br />
“D”<br />
1/8”<br />
32.0<br />
39.0<br />
10.0<br />
33.4<br />
1/4”<br />
32.0<br />
39.0<br />
10.0<br />
33.4<br />
3/8”<br />
34.5<br />
36.5<br />
11.0<br />
33.0<br />
6.3 DIA.MT'G<br />
HOLE 4 PLACES<br />
73.0<br />
2-STATION<br />
ADD-ON BAR<br />
H<br />
25.0<br />
TYP.<br />
ADD<br />
A-UNIT<br />
25.6<br />
1 1/4" N.P.S.M.<br />
CONDUIT BOTH<br />
ENDS<br />
“E”<br />
“F”<br />
“G”<br />
40.9<br />
61.1<br />
30.1<br />
37.9<br />
61.1<br />
31.9<br />
36.5<br />
62.6<br />
34.5<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves with multi-pin connector<br />
Series 92<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 - 3/2 1/8 - 1/4 - 3/8 1.0C v<br />
add-a-unit<br />
stations<br />
for CBM092B<br />
OPERATIONAL BENEFITS<br />
1. The 4--way pilot develops maximum shifting<br />
forces both ways.<br />
2. Memory spring available.<br />
3. Balanced spool, immune to variations of<br />
pressure, also provides high flow.<br />
4. Short stroke with high flow.<br />
5. Bonded seal spool with minimum friction,<br />
shifting in a glass-like finished bore.<br />
6. Pilot with balanced poppet, high flow, short<br />
<strong>and</strong> consistent response times.<br />
7. Wiping effect eliminates sticking.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
SINGLE PRESSURE MODELS<br />
92B-xxx-000-DM-DxxP-xxx<br />
Port size<br />
(see circuit bar)<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
Valve less base<br />
92B-AAA-000-DM-DXXP-XXX<br />
92B-BAA-000-DM-DXXP-XXX<br />
92B-EAA-000-DM-DXXP-XXX<br />
92B-FAA-000-DM-DXXP-XXX<br />
92B-GAA-000-DM-DXXP-XXX<br />
DUAL PRESSURE MODELS (REQUIRES SANDWICH PRESSURE REGULATOR)<br />
Port size<br />
(see circuit bar)<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
Valve less base<br />
92B-CAA-000-DM-DXXP-XXX<br />
92B-DAA-000-DM-DXXP-XXX<br />
SOLENOID OPERATOR ➤<br />
DM-DXX P- X XX *<br />
XX<br />
Voltage<br />
X<br />
Manual operator<br />
XX<br />
Electrical connection<br />
JB 240/60, 220/50<br />
JA 120/60, 110/50<br />
JC 24/60, 24/50<br />
FB 24VDC (1.8 W)<br />
DA 24VDC (5.4 W)<br />
DF 24VDC (12.7 W)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR<br />
Port size<br />
1/8 NPTF<br />
1/4 NPTF<br />
3/8 NPTF<br />
1 Non-locking<br />
2 Locking<br />
xx Other Options<br />
Side cylinder ports<br />
(25 mm)<br />
CBM092B-01ACA-A0*XX<br />
CBM092B-01ACD-A0*XX<br />
CBM092B-01ACG-A0*XX<br />
DM<br />
DG<br />
Plug-in<br />
Plug-in w/ground<br />
Note : Ground wire required for solenoids 30 volts<br />
<strong>and</strong> above.<br />
xx Other Options<br />
CBM092B-01xxx-AOxx<br />
Bottom cylinder ports<br />
(25 mm)<br />
CBM092B-01BCA-A0*XX<br />
CBM092B-01BCD-A0*XX<br />
CBM092B-01BCG-A0*XX<br />
Number of stations (01=1 stations). Available in one (1) or two (2) station lenghts.<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
when add-a-units are added to bars with a multi-pin connector, MOD SD03 should be<br />
included with add-a-unit model number.<br />
* If replaced by BO : circuit bar for single operator valves only.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
GAGE<br />
EA<br />
IN<br />
EB<br />
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 92<br />
O P T I O N S<br />
S<strong>and</strong>wich flow controls available, consult factory.<br />
92B-AAA-000-DM-DXXP-1DM<br />
T E C H N I C A L<br />
D A T A<br />
For lights on valve, replace by B.<br />
For lights <strong>and</strong> diode on valve, replace by F.<br />
For lights <strong>and</strong> MOV on valve, replace by H.<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : 20 to 120 PSI<br />
3 positions : 35 to 120 PSI<br />
External pilot : vacuum to 120 PSI<br />
3 positions : 35 to 120 PSI<br />
20 to 120 PSI 3 positions : 35 to 120 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
6.2 mm<br />
1.0 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 7.6 VA Holding : 4.8 VA<br />
= 1.8 to 12.7 W<br />
24 V=/5.4 W Energize : 8 ms De-energize : 7 ms<br />
60Hz/2.9 W Energize : 7-13 ms De-energize : 12-20 ms<br />
• Pilot valve : DMB-DXXP-XXX-1 including mounting screws 35069 (x2) <strong>and</strong> seal 16544.<br />
• Pressure seal between valve <strong>and</strong> base : 16543. • Mounting screws valve to base (x2) : 35050. • Blanking plate : M-92002.<br />
Options :<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust. • Circuit bar for number of stations > 24.<br />
DIMENSIONS<br />
EA<br />
EB IN<br />
164.0<br />
APPROX.<br />
W/SINGLE<br />
REGULATOR<br />
192.3<br />
APPROX.<br />
SINGLE REG.<br />
W/ DOUBLE<br />
REGULATOR<br />
241.0<br />
APPROX.<br />
W/DOUBLE<br />
REGULATOR<br />
34.0<br />
137.0 118.7<br />
APPROX.<br />
W/ FLOW<br />
CONTROLS<br />
D<br />
B<br />
A<br />
18.4<br />
C<br />
A<br />
EXT.P<br />
25.0<br />
TYP.<br />
25.0<br />
TYP.<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
15.0<br />
B<br />
60.5<br />
APPROX.<br />
FROM C L OF<br />
FLOW CONTROL<br />
1/8",1/4",3/8",<br />
PORTS AVAILABE ON<br />
SIDE OR BOTTOM<br />
70.0<br />
APPROX.<br />
FROM C L OF<br />
REGULATOR<br />
Number of<br />
stations<br />
“H”<br />
1<br />
63.0<br />
2<br />
3<br />
Dimensions are based on 25 mm centerline spacing<br />
Note: Bottom & side cylinder ports not available on the same station<br />
4<br />
5<br />
6<br />
88.0 113.0 138.0 163.0 188.0 213.0 238.0 263.0 288.0<br />
7<br />
8<br />
9<br />
10<br />
MODEL<br />
157.5<br />
APPROX.<br />
W/ REGULATOR<br />
25.0<br />
7.0<br />
TYP.<br />
E<br />
G<br />
25.0<br />
TYP.<br />
25.0<br />
TYP.<br />
1/8" EXTERNAL PILOT<br />
PORT 3 PLACES<br />
52.0<br />
42.0<br />
36.5<br />
25.5<br />
21.5<br />
27.0<br />
162.6<br />
APPROX.<br />
W/DOUBLE<br />
SOLENOID<br />
148.3<br />
APPROX.<br />
W/ SINGLE<br />
SOLENOID<br />
5.5<br />
TYP.<br />
81.5<br />
TYP.<br />
F<br />
40.4<br />
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
A<br />
B<br />
MODIF.<br />
EXT.P<br />
COND<br />
25.5<br />
51.2<br />
73.1<br />
3/8" PORTS<br />
3 HOLES<br />
BOTH ENDS<br />
115.5<br />
Dim.<br />
“A”<br />
“B”<br />
“C”<br />
“D”<br />
1/8”<br />
32.0<br />
39.0<br />
10.0<br />
33.4<br />
1/4”<br />
32.0<br />
39.0<br />
10.0<br />
33.4<br />
3/8”<br />
34.5<br />
36.5<br />
11.0<br />
33.0<br />
6.3 DIA.MT'G<br />
HOLE 4 PLACES<br />
73.0<br />
2-STATION<br />
ADD-ON BAR<br />
H<br />
25.0<br />
TYP.<br />
ADD<br />
A-UNIT<br />
25.6<br />
1 1/4" N.P.S.M.<br />
CONDUIT BOTH<br />
ENDS<br />
“E”<br />
“F”<br />
“G”<br />
40.9<br />
61.1<br />
30.1<br />
37.9<br />
61.1<br />
31.9<br />
36.5<br />
62.6<br />
34.5<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Section 2 Options<br />
Consult “Precautions” before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Codification table for voltages / Wire length / Manual operator / Electrical connection<br />
VALVE CODE ➤<br />
D M - D XX X - X XX<br />
1 2 3 4<br />
OPTIONS AVAILABLE FOR<br />
- pilot operated valves 400, 52 & 92 Series<br />
Consult “Precautions”before use, installation or service of MAC Valves.
OPTIONS<br />
Back<br />
1. VOLTAGE<br />
- D XX X - X XX VOLTAGE<br />
DB 12 VDC (5.4 W)<br />
DC 12 VDC (7.5 W)<br />
DD 24 VDC (7.3 W)<br />
DE 12 VDC (12.7 W)<br />
DK 110 VDC (5.8 W)<br />
DJ 28 VDC (5.7 W)<br />
DL 64 VDC (6.0 W)<br />
DM 36 VDC (5.8 W)<br />
DN 6 VDC (6.0 W)<br />
DR 90 VDC (6,6 W)<br />
DS 110 VDC (7.3 W), 100 VDC (6.0 W)<br />
DT 75 VDC (5.6 W)<br />
DP 48 VDC (5.8 W)<br />
FA 12 VDC (1.8 W)<br />
FE 12 VDC (2.4 W)<br />
FF 24 VDC (2.4 W)<br />
JD 100/60, 100/50, 110/60<br />
2. WIRE LENGTH<br />
- D XX X - X XX WIRE LENGTH<br />
B 24”<br />
C 36”<br />
D 48”<br />
E 72”<br />
F 96”<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Back<br />
3. MANUAL OPERATOR<br />
- D XX X - X XX MANUAL OPERATOR<br />
0 No operator<br />
1 Non-locking recessed<br />
2 Locking recessed<br />
3 Non-locking extended<br />
4 Locking extended<br />
4. ELECTRICAL CONNECTION<br />
- D XX X - X XX ELECTRICAL CONNECTION<br />
BA Flying leads<br />
BK BA with protection diode<br />
BL BA with protection varistor<br />
CA 1/2" NPS conduit<br />
JB Rectangular connector<br />
JD Rectangular connector with light<br />
JM Rectangular connector, male only<br />
KA Square connector<br />
KB Square connector with protection diode<br />
KC Square connector with protection varistor<br />
KD Square connector with light<br />
KE Square connector with light <strong>and</strong> protection diode<br />
KF Square connector with light <strong>and</strong> protection varistor<br />
KJ Square connector (male only)<br />
KK Square connector with protection diode (male only)<br />
KL Square connector with protection varistor (male only)<br />
TA Dual tabs<br />
TB TA with protection diode<br />
TD TA with light<br />
TE TA with light <strong>and</strong> protection diode<br />
TJ Dual tabs (male only)<br />
TK TJ with protection diode<br />
TM TJ with light<br />
TN TJ with light <strong>and</strong> protection diode<br />
*DN Plug-in with diode<br />
*DP Plug-in with M.O.V.<br />
*DH Plug-in with diode & ground<br />
*DJ Plug-in with M.O.V & ground<br />
* These options only apply to the 92 series. All others are for the 400 <strong>and</strong> 52 series.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
PIN #6<br />
PIN #9<br />
MOD. SD09<br />
PIN #1<br />
PIN #5<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 9<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 7 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 2 common wires<br />
PIN #9<br />
PIN #15<br />
MOD. SD15<br />
PIN #1<br />
PIN #8<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 15<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 12 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 3 common wires<br />
PIN #14<br />
PIN #25<br />
MOD. SD25<br />
PIN #1<br />
PIN #13<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 25<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 20 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 5 common wires<br />
Note : Use desired MOD. number after circuit bar part number
O p t i o n s<br />
OPTIONS<br />
Connector termination details<br />
CONNECTOR<br />
SOL 1<br />
SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />
Single solenoid circuit bar<br />
SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />
CONNECTOR<br />
SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />
Double solenoid circuit bar<br />
SD09 SD15 SD25<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
8<br />
COMMON (+)<br />
13<br />
COMMON (+)<br />
21<br />
COMMON (+)<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
9<br />
COMMON (+)<br />
8<br />
SOL. 8<br />
8<br />
SOL. 8<br />
14<br />
COMMON (+)<br />
22<br />
COMMON (+)<br />
9<br />
SOL. 9<br />
9<br />
SOL. 9<br />
10 SOL. 10<br />
10 SOL. 10<br />
11<br />
SOL. 11<br />
11<br />
SOL. 11<br />
12 SOL. 12<br />
12 SOL. 12<br />
15<br />
COMMON (+)<br />
23<br />
COMMON (+)<br />
13<br />
SOL. 13<br />
14 SOL. 14<br />
15<br />
SOL. 15<br />
16 SOL. 16<br />
24<br />
COMMON (+)<br />
17<br />
18 SOL. 18<br />
19<br />
20 SOL. 20<br />
SOL. 17<br />
SOL. 19<br />
25<br />
COMMON (+)
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 800<br />
Circuit bar mounting<br />
cylinder ports<br />
in valve<br />
with shut-off<br />
valve<br />
Sealed solenoid enclosure<br />
Piston assembly<br />
Manual operator<br />
Piston adapter<br />
Bonded spool<br />
2<br />
3<br />
Air/spring return<br />
4 1 5<br />
Internal pilot supply<br />
Optional pilot exhaust<br />
tapped port or<br />
Integral muffler<br />
SERIES FEATURES<br />
• Patented MACSOLENOID ® with its non-burn out feature on AC service.<br />
• Air/spring return on single solenoid valves.<br />
• Use for lube or non-lube service.<br />
• Optional low wattage DC solenoids down to 1 watt.<br />
• Various types of manual operators <strong>and</strong> solenoid enclosures.<br />
• 2 position or 3 position valve configurations.<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 800<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/4” 1.3C v<br />
cylinder ports<br />
in valve<br />
OPERATIONAL BENEFITS<br />
1. Balanced spool, immune to variations of pressure.<br />
2. Short stroke with high flow.<br />
3. The piston (booster) provides maximum shifting<br />
forces.<br />
4. Powerful return force thanks to the combination of<br />
mechanical <strong>and</strong> air springs.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Wiping effect eliminates sticking.<br />
7. Pilot valve with balanced poppet, high flow, short<br />
<strong>and</strong> consistent response times.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-PM-xxxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
A 3 2 B<br />
A 3 2 B<br />
B 2 3 A<br />
B 2 3 A<br />
B 2 3 A<br />
5 1<br />
4<br />
5 1<br />
4<br />
4 1 5<br />
4 1 5<br />
4 1 5<br />
1/4” NPTF<br />
811C-PM-XXYZZ-172<br />
821C-PM-XXYZZ-172<br />
825C-PM-XXYZZ-572<br />
825C-PM-XXYZZ-672<br />
825C-PM-XXYZZ-872<br />
SOLENOID OPERATOR ➤<br />
XX Y ZZ *<br />
Voltage<br />
11 120/60, 110/50<br />
12 240/60, 220/50<br />
22 24/50, 24/60<br />
59 24VDC (2.5 W)<br />
87 24VDC (17.1 W)<br />
61 24VDC (8.5 W)<br />
xx Other Options<br />
Manual operator<br />
1 Non-locking<br />
2 Locking<br />
xx Other Options<br />
Electrical connection<br />
JB Rectangular connector<br />
JD Rectangular connector<br />
with light<br />
BA Flying leads (18”)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR**<br />
Port size<br />
(Spacing 31 mm)<br />
3/8” NPTF<br />
St<strong>and</strong>ard circuit bar<br />
EBM800A-001A-XX<br />
EBM800A-xxxx-xx<br />
Circuit bar with flow controls<br />
(2 per station)<br />
EBM800A-002A-XX<br />
Number of stations (03=3 stations)<br />
Other options available. Consult factory.<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 800<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : single operator <strong>and</strong> 3 positions : 20 to 150 PSI<br />
double operator : 10 to 150 PSI<br />
External pilot : vacuum to 200 PSI<br />
Single operator <strong>and</strong> 3 positions : 20 to 150 PSI<br />
Double operator : 20 to 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
7 mm<br />
1/4" : 1.3 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 14.8 VA Holding : 10.9 VA<br />
= 1 to 17.1 W<br />
24 V=/8.5 W Energize : 8 ms De-energize : 10ms<br />
60Hz/6 W Energize : 5-11 ms De-energize : 9-16 ms<br />
• Pilot valve : PME-XXYZZ. • Mounting screw pilot to main valve : 34364. • Blanking plate : M-08008.<br />
• Mounting screw valve to bar (x2): 35249. • Flow control : N08006.<br />
Options :<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust. • Explosion-proof model.<br />
DIMENSIONS<br />
183,2<br />
136,0<br />
91,5<br />
56,0<br />
89,2<br />
IN<br />
18,5<br />
EXH<br />
EXH<br />
15,5<br />
7,0<br />
EX IN EX<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
3<br />
15,0 12,7<br />
15,0 12,7<br />
4<br />
3<br />
4<br />
3<br />
4<br />
EX IN EX<br />
Ø 6,7<br />
2 MTG HOLES<br />
12,0<br />
42,0<br />
72,0<br />
84,0<br />
FLOW CONTROL<br />
3/8”<br />
7,0<br />
31,0<br />
31,5<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />
Series 800<br />
Function Port size Flow (Max) Circuit bar mounting<br />
5/2 - 5/3 1/4” 1.3C v<br />
with shut-off<br />
valve<br />
OPERATIONAL BENEFITS<br />
1. Balanced spool, immune to variations of pressure.<br />
2. Short stroke with high flow.<br />
3. The piston (booster) provides maximum shifting<br />
forces.<br />
4. Powerful return force thanks to the combination of<br />
mechanical <strong>and</strong> air springs.<br />
5. Bonded spool with minimum friction, shifting in a<br />
glass-like finished bore.<br />
6. Wiping effect eliminates sticking.<br />
7. Pilot valve with balanced poppet, high flow, short<br />
<strong>and</strong> consistent response times.<br />
8. Long service life.<br />
Reset<br />
HOW TO ORDER<br />
xxxx-PM-xxxxx-xxx<br />
HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />
Port size<br />
5/2<br />
Single operator<br />
5/2<br />
Double operator<br />
5/3<br />
Closed center<br />
5/3<br />
Open center<br />
5/3<br />
Pressure center<br />
A 3 2 B<br />
A 3 2 B<br />
B 2 3 A<br />
B 2 3 A<br />
B 2 3 A<br />
5 1<br />
4<br />
5 1<br />
4<br />
4 1 5<br />
4 1 5<br />
4 1 5<br />
1/4” NPTF<br />
811C-PM-XXYZZ-172<br />
821C-PM-XXYZZ-172<br />
825C-PM-XXYZZ-572<br />
825C-PM-XXYZZ-672<br />
825C-PM-XXYZZ-872<br />
SOLENOID OPERATOR ➤<br />
XX Y ZZ *<br />
Voltage<br />
11 120/60, 110/50<br />
12 240/60, 220/50<br />
22 24/50, 24/60<br />
59 24VDC (2.5 W)<br />
87 24VDC (17.1 W)<br />
61 24VDC (8.5 W)<br />
xx Other Options<br />
Manual operator<br />
1 Non-locking<br />
2 Locking<br />
xx Other Options<br />
Electrical connection<br />
JB Rectangular connector<br />
JD Rectangular connector<br />
with light<br />
BA Flying leads (18”)<br />
xx Other Options<br />
HOW TO ORDER CIRCUIT BAR**<br />
Port size<br />
(Spacing 31 mm)<br />
w/o inlet shut-off valve<br />
EBI800A-xxxx-xx<br />
w/ inlet shut-off valve<br />
3/8" NPTF<br />
EBI800A-001A-XX<br />
EBI800A-002A-XX<br />
Number of stations (03=3 stations)<br />
Other options available. Consult factory.<br />
Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />
Consult “Precautions”before use, installation or service of MAC Valves.
100%<br />
100%<br />
WARRANTY<br />
18<br />
O F<br />
P R O D U C T I O N<br />
T E S T E D<br />
100% MONTHS<br />
Series 800<br />
T E C H N I C A L<br />
D A T A<br />
Fluid :<br />
Pressure range :<br />
Pilot pressure :<br />
Lubrication :<br />
Filtration :<br />
Temperature range :<br />
Orifice :<br />
Flow (at 6 bar, P=1bar) :<br />
Leak rate :<br />
Coil :<br />
Voltage range :<br />
Protection :<br />
Power :<br />
Response times :<br />
Spare parts :<br />
Compressed air, vacuum, inert gases<br />
Internal pilot : single operator <strong>and</strong> 3 positions : 20 to 150 PSI<br />
double operator : 10 to 150 PSI<br />
External pilot : vacuum to 200 PSI<br />
Single operator <strong>and</strong> 3 positions : 20 to 150 PSI<br />
Double operator : 20 to 150 PSI<br />
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />
40 μ<br />
0°F to 120°F (-18°C to +50°C)<br />
7 mm<br />
1/4" : 1.3 C v<br />
50 cm 3 /min<br />
General purpose class A, continuous duty, encapsulated<br />
-15% to +10% of nominal voltage<br />
NEMA 4<br />
Inrush : 14.8 VA Holding : 10.9 VA<br />
= 1 to 17.1 W<br />
24 V=/8.5 W Energize : 8 ms De-energize : 10ms<br />
60Hz/6 W Energize : 5-11 ms De-energize : 9-16 ms<br />
• Pilot valve : PME-XXYZZ. • Mounting screw pilot to main valve : 34364. • Blanking plate : M-08011.<br />
• Shut-off valve : M-08010. • Mounting screw valve to bar (x2): 35249.<br />
Options :<br />
• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust. • Explosion-proof model.<br />
DIMENSIONS<br />
183,2<br />
91,6<br />
56,0<br />
19,0<br />
K<br />
C<br />
O<br />
L<br />
3<br />
2<br />
K<br />
C<br />
O<br />
L<br />
102,2<br />
L<br />
K<br />
L<br />
O<br />
C<br />
O<br />
O<br />
K<br />
C<br />
L<br />
K<br />
C<br />
3<br />
3<br />
3<br />
2<br />
2<br />
2<br />
L<br />
K<br />
L<br />
O<br />
C<br />
O<br />
K<br />
C<br />
O<br />
L<br />
K<br />
C<br />
13,0<br />
SHOWN IN OPEN<br />
POSITION<br />
3/8”<br />
Ø 4<br />
MTG. HOLES<br />
9,5<br />
19,0<br />
26,0<br />
13,0<br />
19,0<br />
SHOWN IN<br />
CLOSED POSITION<br />
EXH<br />
40,0<br />
111,0<br />
71,0<br />
Consult “Precautions”before use, installation or service of MAC Valves.
Section 2 Options<br />
Consult “Precautions” before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Codification table for voltages / Manual operator / Electrical connection / Wire length<br />
VALVE CODE ➤<br />
- XX Y ZZ (-VV)<br />
1 2 3 4<br />
OPTIONS AVAILABLE FOR<br />
- valves type 800 Series<br />
Consult “Precautions”before use, installation or service of MAC Valves.
OPTIONS<br />
Back<br />
1. VOLTAGE<br />
- XX Y ZZ VOLTAGE<br />
11 120/60 - 110/50<br />
12 240/60 - 220/50<br />
13 100/60 - 100/50<br />
15 200/60 - 200 V~/50 Hz<br />
16 10/60<br />
20 6/60<br />
21 12/50 - 12/60<br />
22 24/60 - 24/50<br />
23 32/60 - 32/50<br />
24 48/60 - 42/50<br />
26 380/50, 440/50 -440/60,<br />
480/60-CLSF<br />
29 200/60<br />
34 127/50 - 120/50<br />
35 48/50<br />
36 16/60<br />
B1 24/50<br />
50 24 VDC (6W)<br />
51 24 VDC (4W)<br />
54 12 VDC (4W)<br />
55 12 VDC (6W)<br />
57 12 VDC (2.5W)<br />
59 24 VDC (2.5W)<br />
60 12 VDC (8.5W)<br />
61 24 VDC (8.5W)<br />
64 6 VDC (6W)<br />
65 32 VDC (7W)<br />
66 48 VDC (5.8W)<br />
67 64 VDC (7.5W)<br />
68 120 VDC (6.4W)<br />
75 90 VDC (8.8W)<br />
76 100 VDC (6.9W)<br />
*84 125 VDC (10.9W)<br />
*87 24 VDC (17.1W)<br />
*88 12 VDC (17.4W)<br />
*89 36 VDC (18.8W)<br />
90 28 VDC (8.2W)<br />
*91 6 VDC (10.6W)<br />
92 190 VDC (6.5W)<br />
94 3 VDC (7W)<br />
95 38 VDC (6.4W)<br />
A1<br />
24 VDC (1.0W)<br />
A2<br />
12 VDC (1.0W)<br />
A3<br />
9 VDC (1.0W)<br />
MOD. DD01 : Protection diode (DC)<br />
MOD. MOV1 : Protection varistor (AC)<br />
MOD. DD01 : max. 8,5 W<br />
MOD. MOV1 : max. 8,5 W<br />
* Voltages are CLSF only<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
Back<br />
2. MANUAL OPERATOR<br />
- XX Y ZZ MANUAL OPERATOR<br />
0 No operator<br />
1 Non-locking recessed<br />
2 Locking recessed<br />
3 Non-locking extended<br />
4 Locking extended<br />
3. ELECTRICAL CONNECTION<br />
- XX Y ZZ ELECTRICAL CONNECTION<br />
AA Wiring box with 1/2" NPS conduit<br />
BA Flying leads<br />
CA 1/2" NPS conduit<br />
CC 1/2" NPT conduit<br />
FA Military type 2 PIN<br />
GA Military type 3 PIN<br />
HA AA with ground wire<br />
JA Square connector<br />
JB Rectangular connector<br />
JC Square connector with light<br />
JD Rectangular connector with light<br />
JJ Square connector, male only<br />
JM Rectangular connector, male only<br />
NA CA with ground wire<br />
NC CC with ground wire<br />
RA 3/8" NPS conduit<br />
CD 20 mm conduit<br />
4. WIRE LENGTH<br />
- XX Y ZZ (-VV) WIRE LENGTH<br />
AA 18”<br />
AB 24”<br />
AD 36”<br />
AE 48”<br />
AF 72”<br />
AG 6”<br />
AR 12”<br />
AU 120”<br />
BA 60”<br />
BB 144”<br />
Consult “Precautions”before use, installation or service of MAC Valves.
O p t i o n s<br />
OPTIONS<br />
PIN #6<br />
PIN #9<br />
MOD. SD09<br />
PIN #1<br />
PIN #5<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 9<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 7 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 2 common wires<br />
PIN #9<br />
PIN #15<br />
MOD. SD15<br />
PIN #1<br />
PIN #8<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 15<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 12 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 3 common wires<br />
PIN #14<br />
PIN #25<br />
MOD. SD25<br />
PIN #1<br />
PIN #13<br />
TECHNICAL DATA<br />
• Type «SUB_D»<br />
• Number of contacts : 25<br />
• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />
• Operating current 5 A/contact<br />
• Rated voltage 125 V~<br />
• Temp. range –40° to +125°C<br />
• Insulation resistance 5.0 9 <br />
• Protection class IP40 (DIN 40050)<br />
• Number of solenoids : 20 max.<br />
• Max. 24 V=/5.4 W per solenoid<br />
• 5 common wires<br />
Note : Use desired MOD. number after circuit bar part number
O p t i o n s<br />
OPTIONS<br />
Connector termination details<br />
CONNECTOR<br />
SOL 1<br />
SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />
Single solenoid circuit bar<br />
SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />
CONNECTOR<br />
SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />
Double solenoid circuit bar<br />
SD09 SD15 SD25<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
1<br />
SOL. 1<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
2<br />
SOL. 2<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
3<br />
SOL. 3<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
4<br />
SOL. 4<br />
8<br />
COMMON (+)<br />
13<br />
COMMON (+)<br />
21<br />
COMMON (+)<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
5<br />
SOL. 5<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
6<br />
SOL. 6<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
7<br />
SOL. 7<br />
9<br />
COMMON (+)<br />
8<br />
SOL. 8<br />
8<br />
SOL. 8<br />
14<br />
COMMON (+)<br />
22<br />
COMMON (+)<br />
9<br />
SOL. 9<br />
9<br />
SOL. 9<br />
10 SOL. 10<br />
10 SOL. 10<br />
11<br />
SOL. 11<br />
11<br />
SOL. 11<br />
12 SOL. 12<br />
12 SOL. 12<br />
15<br />
COMMON (+)<br />
23<br />
COMMON (+)<br />
13<br />
SOL. 13<br />
14 SOL. 14<br />
15<br />
SOL. 15<br />
16 SOL. 16<br />
24<br />
COMMON (+)<br />
17<br />
18 SOL. 18<br />
19<br />
20 SOL. 20<br />
SOL. 17<br />
SOL. 19<br />
25<br />
COMMON (+)
364<br />
PRECAUTIONS AND WARNINGS<br />
CONCERNING THE APPLICATION, INSTALLATION AND SERVICE OF MAC VALVES AND OTHER MAC VALVES PRODUCTS<br />
The warnings <strong>and</strong> precautions below are important to be read <strong>and</strong> understood before<br />
designing into a system any MAC Valves products, <strong>and</strong> before installing or servicing any MAC Valves<br />
product. Improper use, installation or servicing of any MAC Valves product in some systems could<br />
create a hazard to personnel or equipment. No distinction in importance should be made between<br />
the terms warnings <strong>and</strong> precautions.<br />
WARNING : .<br />
Under no circumstances are MAC Valves products to be used in any application or in any manner<br />
where failure of the MAC Valves product to operate as intended could in any way jeopardize the<br />
safety of the operator or any other person or property.<br />
• Do not operate outside of pressure range listed on a valve label or outside of the designated<br />
temperature range.<br />
• Air supply must be clean <strong>and</strong> dry. Moisture or contamination can affect proper operation of the<br />
valve.<br />
• Before attempting to repair, adjust or clean a MAC Valves product, consult catalog, parts & operation<br />
sheet, or factory for proper maintenance procedures, lubrication <strong>and</strong> cleaning agents. Never<br />
attempt to repair or perform other maintenance with air pressure to the valve.<br />
• If air line lubrication is used do not use any lubrication other than those recommended in the<br />
catalog, parts & operation sheet or by the factory.<br />
APPLICATION PRECAUTIONS : .<br />
INDUSTRIAL USE -<br />
• MAC Valve products are intended for general use in industrial pneumatic <strong>and</strong>/or vacuum systems.<br />
They are general purpose industrial products with literally thous<strong>and</strong>s of different applications in<br />
industrial systems. These products are not inherently dangerous, but they are only a component of<br />
an overall system. The system in which they are used must provide adequate safeguards to prevent<br />
injury or damage in the event failure occurs, whether it be failure of switches, regulators, cylinders,<br />
valves or any other component.<br />
POWER PRESSES -<br />
MAC Valve products are not designed nor intended to be used to operate <strong>and</strong>/or control the<br />
operation of clutch <strong>and</strong>/or brake systems on power presses. There are special products on the market<br />
for such use.<br />
2-POSITION VALVES -<br />
Some MAC valves are 2-position, 4-way valves. When air is supplied to the inlet port(s) of these valves,<br />
there will always be a flow path from the inlet to one of the outlets regardless of which of the two<br />
positions the valve is situated. Therefore, if pressurized air retained in the system would present a<br />
hazard in the application or servicing of the valve or system, a separate method in the system must<br />
be provided to remove the trapped air.<br />
3- POSITION VALVES-<br />
Some MAC valves are 3-position, 4-way valves. These valves are either double solenoid or double<br />
remote air operated.<br />
If either of the two operators is in control, air supplied to the inlet port(s) will pass through the valve<br />
to one of the outlets as on 2-position, 4-way valves. However, if neither operator is in control, the<br />
valve moves to a center position. Listed below are the various center position functions :<br />
A. CLOSED CENTER-<br />
With this type valve, when in the center position all ports are blocked (inlets <strong>and</strong> exhausts) meaning<br />
the air at both outlet ports is trapped. If trapping the air in both outlet ports would present a hazard<br />
in the application or servicing, a separate method in the system must be provided to remove the<br />
trapped air or this type valve should not be used.<br />
B. OPEN CENTER-<br />
With this type valve, when in the center position, the inlet port(s) is blocked <strong>and</strong> the two outlet ports<br />
are open to the exhaust port(s) of the valve. If having no air in either outlet port would present a<br />
hazard in the application or servicing, this type valve should not be used.<br />
C. PRESSURE CENTER-<br />
With this type valve, when in the center position, the inlet port(s) is connected to both outlet ports of<br />
the valve. If having pressurized air to either or both outlet ports would present a hazard in the<br />
application or servicing of the valve or system, a separate method in the system must be<br />
provided to remove the retained air or this type valve should not be used.<br />
OPERATING SPECIFICATIONS -<br />
MAC Valves products are to be installed only on applications that meet all operating specifications<br />
described in the MAC catalog for the MAC Valves product.<br />
MANUAL OPERATORS-<br />
Most MAC valves can be ordered with manual operators. Manual operators when depressed, are<br />
designed to shift the valve to the same position as would the corresponding solenoid or remote air<br />
pilot operator if it were activated. Care must be taken to order a type, if any, that will be safe for the<br />
physical location of the manual operator in the system. If intentional or accidental operation of a<br />
valve by a manual operator could cause personal injury or property damage, a manual operator<br />
should not be used.<br />
REMOTE AIR OPERATED VALVES<br />
Pilot valves supplying signal pressure to remote air operated valves should be 3-way valves with<br />
adequate supply <strong>and</strong> exhaust capacity to provide positive pressurizing <strong>and</strong> exhausting of the pilot<br />
supply line. Pilot lines should be open to exhaust when valves are deenergized.<br />
INSTALLATION PRECAUTIONS : .<br />
A. Do not install any MAC Valves product without first turning off air (bleed system completely) <strong>and</strong><br />
electricity to the machine.<br />
B. MAC Valves products should only be installed by qualified, knowledgeable personnel who<br />
underst<strong>and</strong> how the specific valve is to be pneumatically piped <strong>and</strong> electrically connected (where<br />
applicable). Flow paths through the valve are shown in the catalog <strong>and</strong> on the valve by use of ANSI<br />
or ISO type st<strong>and</strong>ard graphic symbols. Do not install unless these symbols <strong>and</strong> the valve functions<br />
<strong>and</strong> operations are thoroughly understood.<br />
C. If air line lubrication is used do not use any lubrication other than those recommended in the<br />
catalog, parts & operation sheet or by the factory.<br />
SERVICE PRECAUTIONS :<br />
A. Do not service or remove from service any MAC Valves product without first shutting off both the<br />
air <strong>and</strong> electricity to the valve <strong>and</strong> making certain no pressurized air which could present a hazard<br />
is retained in the system.<br />
B. MAC Valves products should only be serviced or removed from service by qualified, knowledgeable<br />
personnel who underst<strong>and</strong> how the specific product is used <strong>and</strong>/or how the specific valve is piped<br />
<strong>and</strong> used <strong>and</strong> whether there is air retained in the connecting lines to the valve or electric power still<br />
connected to the valve.<br />
C. Before attempting to repair, adjust or clean a MAC Valves product, consult catalog, parts &<br />
operation sheet, or factory for proper maintenance procedures, lubrication <strong>and</strong> cleaning agents.<br />
Never attempt to repair or perform other maintenance with air pressure to the valve.<br />
D. MAC Valves products are never to be stepped on while working on a machine. Damage to a MAC<br />
valve, or other product or lines to the product (either air or electrical lines) or accidental activation<br />
of a manual operator on the valve could result in personal injury or property damage.<br />
LIMITATION OF GUARANTEE .<br />
This Guarantee is limited to the replacement or rebuilding of any valve or other product which should<br />
fail to operate properly. Valves or other products, under the MAC Guarantee, must be returned (with<br />
or without bases) transportation prepaid <strong>and</strong> received at our factory within the Guarantee period.<br />
They will be returned to the customer at the expense of MAC Valves, Inc., <strong>and</strong> will carry the same<br />
guarantee as provided under the Flat Rate Rebuild Program.<br />
DISCLAIMER OF GUARANTEE .<br />
No claims for labor, material, time, damage, or transportation are allowable nor will any valve or other<br />
product be replaced or rebuilt under this guarantee which has been damaged by the purchaser not<br />
in the normal course of its use <strong>and</strong> maintenance during the warranty period. The guarantee does not<br />
apply to loss or damage caused by fire, theft, riot, explosion, labor dispute, act of God, or other causes<br />
beyond the control of MAC Valves,Inc. MAC Valves, Inc. shall in no event be liable for remote, special<br />
or consequential damages under the MAC Guarantee, nor under any implied warranties, including<br />
the implied warranty of merchantability.<br />
The above Guarantee is our manner of extending the engineering <strong>and</strong> service resources of the MAC<br />
Valves, Inc. organization to assure our customer long, <strong>and</strong> continued satisfaction.