C i r c u i t B a r<br />

®


CIRCUIT BAR ®<br />

CIRCUIT BAR ® is an extruded block of aluminum with pneumatic circuits machined right in the bar.<br />

The design of these circuits can be very simple or complex depending upon the requirements of the<br />

application.<br />

CIRCUIT BAR ® are a means by which individual components (i.e. valves, regulators <strong>and</strong> flow controls)<br />

comprising a circuit, can be combined into one extruded CIRCUIT BAR ® . The CIRCUIT BAR ® will eliminate<br />

extra piping <strong>and</strong> fittings, as well as saving space <strong>and</strong> money.<br />

Contact your local MAC distributor for more information as to how MAC’S CIRCUIT BAR ® can satisfy<br />

your needs.<br />

Introduction<br />

Section 1 Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Introduction<br />

Let us show you via high performance demonstration kits <strong>and</strong> animated software,<br />

HOW MAC’S PERFORMANCE ADVANTAGES HELP MAKE YOUR<br />

EQUIPMENT MORE RELIABLE - FASTER - MORE REPEATABLE.<br />

TLD<br />

Traveling Lab Demonstration measures critical valve<br />

performance characteristics - Shifting forces,<br />

Response Time, Speed, Repeatability <strong>and</strong> Flow.<br />

PLD<br />

Proportional Lab Demonstration measures critical<br />

proportional regulation characteristics - Response<br />

Time, Accuracy, Hysterisis, Repeatability <strong>and</strong> Flow.<br />

Animation<br />

Animated Software shows inner workings of various<br />

Air Valves Designs - Powerful educational tool for<br />

learning about how air valves function.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Product range<br />

3-way solenoid operated valves<br />

#10-32 to 2 1/2” port size Cv .10 to 65.0<br />

4-way solenoid operated valves<br />

#10-32 to 1 1/2” port size Cv .10 to 15.9<br />

Proportional pressure control valves<br />

St<strong>and</strong> alone or Multi-Pressure Pak ®<br />

Analog or Digital with an overall accuracy range of ±.5% to ±2.5% of full scale<br />

Field bus products<br />

Communication Electronics with a variety of MAC Valves’ products<br />

Input <strong>and</strong> Output capability with a variety of protocols<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Section 1 Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Function Port size Flow (Max) C v Circuit bar mounting Series<br />

non plug-in<br />

cylinder ports<br />

in base<br />

non plug-in<br />

cylinder ports<br />

in valve<br />

plug-in<br />

plug-in<br />

with F. C.<br />

plug-in<br />

with Pr. Reg.<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

add-on style<br />

plug-in<br />

add-on style<br />

plug-in<br />

with F. C.<br />

add-on style<br />

plug-in<br />

with Pr. Reg.<br />

3/2<br />

M5 - #10-32<br />

0.11<br />

3/2<br />

3/2<br />

#10-32 - 1/8”<br />

M5 - #10-32<br />

0.11<br />

0.10<br />

34<br />

3/2<br />

M5 - #10-32<br />

0.09<br />

3/2<br />

1/8” NPTF - #10-32 UNF<br />

0.10<br />

35<br />

3/2<br />

1/4” - 3/8”<br />

0.5<br />

3/2<br />

1/8” - 1/4”, 6mm tube receptacle<br />

0.5<br />

37<br />

3/2<br />

1/8” - 1/4”<br />

0.5<br />

5/2 - 3/2<br />

M5 - #10-32<br />

0.093<br />

5/2 - 3/2<br />

#10-32 - 1/8”<br />

0.093<br />

5/2 - 3/2<br />

M5 - #10-32<br />

0.09<br />

44<br />

5/2 - 3/2<br />

M5 - #10-32<br />

0.08<br />

5/2 - 3/2<br />

M5 - #10-32<br />

0.07<br />

4/2<br />

1/8” NPTF - #10-32 UNF<br />

0.10<br />

45<br />

5/2<br />

5/2<br />

1/8” - 1/4”, 6mm tube receptacle<br />

1/8” - 1/4”<br />

0.5<br />

0.5<br />

47<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Function Port size Flow (Max) C v Circuit bar mounting Series<br />

add-on style<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

plug-in<br />

add-a-unit<br />

stations<br />

plug-in<br />

add-a-unit<br />

stations<br />

with F. C.<br />

plug-in<br />

add-a-unit<br />

stations<br />

with Pr. Reg.<br />

plug-in<br />

add-a-unit<br />

stations with<br />

F. C. <strong>and</strong> Pr. Reg.<br />

plug-in with<br />

pre-wired<br />

connector<br />

plug-in<br />

with F. C. <strong>and</strong><br />

pre-wired<br />

connector<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> pre-wired<br />

connector<br />

din rail,<br />

plug-in with<br />

pre-wired<br />

connector<br />

3/2<br />

M5 - #10-32<br />

0.10<br />

3/2<br />

M5 - #10-32<br />

0.09<br />

34<br />

3/2<br />

M5 - #10-32, 4mm tube receptacle<br />

0.11<br />

3/2<br />

3/2<br />

1/8” - 1/4”, 6mm tube receptacle<br />

1/8” - 1/4”<br />

0.5<br />

0.5<br />

37<br />

5/2 - 3/2<br />

M5 - #10-32<br />

0.09<br />

5/2 - 3/2<br />

M5 - #10-32<br />

0.07<br />

5/2<br />

5/2<br />

M5 - #10-32<br />

M5 - #10-32<br />

0.09<br />

0.08<br />

44<br />

5/2<br />

M5 - #10-32<br />

0.07<br />

5/2 - 3/2<br />

M5 - #10-32, 4mm tube receptacle<br />

0.10<br />

5/2<br />

5/2<br />

1/8” - 1/4”, 6mm tube receptacle<br />

1/8” - 1/4”<br />

0.5<br />

0.5<br />

47<br />

Function Port size Flow (Max) C v Circuit bar mounting Series<br />

din rail,<br />

plug-in with F. C.<br />

<strong>and</strong> pre-wired<br />

connector<br />

non plug-in<br />

non plug-in<br />

with Pr. Reg.<br />

plug-in<br />

with side<br />

Pr. Reg.<br />

plug-in<br />

with integral<br />

terminal strip<br />

plug-in with<br />

integral<br />

terminal strip<br />

<strong>and</strong> side Pr. Reg.<br />

non plug-in<br />

cylinder ports<br />

in base with<br />

Pr. Reg.<br />

non plug-in<br />

add-on style<br />

cylinder ports<br />

in base<br />

non plug-in<br />

add-a-unit<br />

stations<br />

3/2<br />

M5 - #10-32, 4mm tube receptacle<br />

0.11<br />

34<br />

3/2<br />

1/8” NPTF - #10-32 UNF<br />

0.10<br />

35<br />

3/2<br />

1/8” - 1/4”, 6mm tube receptacle<br />

0.5<br />

37<br />

4/2<br />

1/8” NPTF - #10-32 UNF<br />

0.10<br />

45<br />

5/2<br />

1/8” - 1/4”, 6mm tube receptacle<br />

0.5<br />

47<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Function Port size Flow (Max) C v Circuit bar mounting Series<br />

cylinder ports<br />

in valve<br />

add-on style<br />

cylinder ports<br />

in valve<br />

cylinder ports<br />

in base<br />

add-on style<br />

cylinder ports<br />

in base<br />

add-a-unit<br />

stations for<br />

CBM052A bar<br />

add-a-unit<br />

stations for<br />

CBP052A bar<br />

non plug-in<br />

with or<br />

without F. C.<br />

non plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

plug-in<br />

with s<strong>and</strong>wich<br />

Pr. Reg.<br />

3/2<br />

1/8” - 1/4”<br />

1.2<br />

52<br />

4/2<br />

1/8” NPTF - #10-32 UNF<br />

0.10<br />

45<br />

5/2 - 5/3<br />

1/4”<br />

1.3<br />

800<br />

Function Port size Flow (Max) C v Circuit bar mounting Series<br />

plug-in with<br />

integral terminal<br />

strip <strong>and</strong><br />

s<strong>and</strong>wich Pr. Reg.<br />

plug-in with<br />

integral<br />

terminal strip<br />

with F. C.<br />

plug-in with<br />

integral terminal<br />

strip with<br />

Pr. Reg. <strong>and</strong> F. C.<br />

non plug-in<br />

cyl. ports in<br />

valve with<br />

opt. F. C.<br />

non plug-in<br />

cyl. ports in<br />

base with<br />

opt. F. C.<br />

add-on style<br />

non plug-in cyl.<br />

ports in valve<br />

with opt. F. C.<br />

add-on style<br />

non plug-in cyl.<br />

ports in base<br />

with opt. F. C.<br />

non plug-in<br />

cyl. ports<br />

in valve with<br />

opt. Pr. Reg.<br />

add-on style<br />

non plug-in<br />

cyl. ports<br />

in base<br />

4/2<br />

1/8” NPTF - #10-32 UNF<br />

0.10<br />

45<br />

5/2<br />

5/2<br />

3/8”<br />

1/8” - 1/4”, 6mm tube receptacle<br />

0.5<br />

0.5<br />

47<br />

Function Port size Flow (Max) C v Circuit bar mounting Series<br />

add-on style<br />

non plug-in cyl.<br />

ports in base<br />

with Pr. Reg.<br />

low profile<br />

cylinder ports<br />

in valve<br />

low profile<br />

cylinder ports<br />

in base<br />

mid profile<br />

cylinder ports<br />

in valve<br />

mid profile -<br />

add on style<br />

cylinder ports<br />

in valve<br />

add-a-unit<br />

stations for<br />

CBM403A bar<br />

mid profile<br />

cylinder ports<br />

in base<br />

mid profile -<br />

add on style<br />

cylinder ports<br />

in base<br />

add-a-unit<br />

stations for<br />

CBM404A bar<br />

5/2<br />

1/8” - 1/4”, 6mm tube receptacle<br />

0.5<br />

47<br />

5/2 - 5/3<br />

5/2 - 5/3<br />

1/8” - 1/4”<br />

1/8”<br />

1.0<br />

1.0<br />

400<br />

Function Port size Flow (Max) C v Circuit bar mounting Series<br />

high profile<br />

cylinder ports<br />

in base<br />

high profile -<br />

add on style<br />

cylinder ports<br />

in base<br />

add-a-unit<br />

stations for<br />

CBM405A bar<br />

st<strong>and</strong>ard<br />

add-on style<br />

add-a-unit<br />

stations for<br />

CBM092B<br />

with shut-off<br />

valve<br />

5/2 - 5/3<br />

1/8” - 1/4”<br />

1.0<br />

400<br />

5/2 - 5/3 - 3/2<br />

1/8 - 1/4 - 3/8<br />

1.0<br />

92<br />

5/2 - 5/3<br />

1/4”<br />

1.3<br />

800<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Circuit bar mounting<br />

non plug-in<br />

cylinder ports<br />

in base<br />

non plug-in<br />

cylinder ports<br />

in valve<br />

plug-in<br />

plug-in<br />

with F. C.<br />

plug-in<br />

with Pr. Reg.<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

add-on style<br />

plug-in<br />

add-on style<br />

plug-in<br />

with F. C.<br />

add-on style<br />

plug-in<br />

with Pr. Reg.<br />

add-on style<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

plug-in<br />

add-a-unit<br />

stations<br />

plug-in<br />

add-a-unit<br />

stations<br />

with F. C.<br />

plug-in<br />

add-a-unit<br />

stations<br />

with Pr. Reg.<br />

plug-in<br />

add-a-unit<br />

stations with<br />

F. C. <strong>and</strong> Pr. Reg.<br />

plug-in with<br />

pre-wired<br />

connector<br />

plug-in with<br />

F. C. <strong>and</strong><br />

pre-wired<br />

connector<br />

plug-in with<br />

Pr. Reg. <strong>and</strong><br />

pre-wired<br />

connector<br />

din rail,<br />

plug-in with<br />

pre-wired<br />

connector<br />

din rail,<br />

plug-in with<br />

F. C. <strong>and</strong> prewired<br />

connector<br />

Manual operator<br />

Armature<br />

Coil<br />

Push pin<br />

Poppet<br />

“D” seal<br />

Valve spring<br />

SERIES FEATURES<br />

• High force MACSOLENOID ® .<br />

• Universal porting.<br />

• #10-32 or M5 ports.<br />

• Rated for lubricated or non-lubricated service.<br />

• 10mm direct operated.<br />

• Cylinder port in valve or in circuit bar.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.11C v<br />

non plug-in<br />

cylinder ports<br />

in base<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-Gxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Pressure range : 0 to 120 PSI<br />

1 3<br />

34B-LOO-GXXX-XXX<br />

1 3<br />

34B-NOO-GXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

A 18”<br />

1 Non-locking<br />

KA<br />

Mini connector<br />

DD 24VDC (2.5 W)<br />

C 36”<br />

KT<br />

Mini connector<br />

with light<br />

DF 24VDC (4.0 W)<br />

xx Other Options<br />

x<br />

Other Options<br />

BA<br />

BT<br />

xx<br />

Flying leads<br />

Flying leads with light<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

EBP34B-xxxx-xx<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

M5<br />

# 10-32<br />

EBP34B-001D-XX<br />

EBP34B-001B-XX<br />

EBP34B-002D-XX<br />

EBP34B-002B-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

1.8 mm<br />

4 W : 0.11C v , 2.5 W : 0.084C v , 1.8 W : 0.061C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 3.4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory.<br />

DIMENSIONS<br />

1/8” - NPT PORTS 1 & 3<br />

EACH END<br />

59,0<br />

52,0<br />

C L C L C L<br />

2<br />

1<br />

6,0<br />

22,0<br />

12,5<br />

3<br />

7,5<br />

2,0<br />

10,5 18,0<br />

4,5<br />

4,0<br />

14,5<br />

12,5<br />

14,0<br />

34,0<br />

18,0<br />

34,0<br />

OPTIONAL BOTTOM<br />

PORTS<br />

18,0<br />

4,5<br />

4,2 DIA.<br />

MOUNTING HOLES<br />

4,0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting<br />

3/2 NO-NC # 10-32 - 1/8“ 0.11C v<br />

non plug-in<br />

cylinder ports<br />

in valve<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-Gxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Valve port size<br />

Universal valve<br />

NC only valve<br />

2<br />

2<br />

M5<br />

# 10-32<br />

1 3<br />

34B-ABA-GXXX-XXX<br />

34B-AAA-GXXX-XXX<br />

1 3<br />

34B-ABB-GXXX-XXX<br />

34B-AAB-GXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

A 18”<br />

1 Non-locking<br />

KA<br />

Mini connector<br />

DD 24VDC (2.5 W)<br />

C 36”<br />

KT<br />

Mini connector<br />

with light<br />

DF 24VDC (4.0 W)<br />

xx Other Options<br />

x<br />

Other Options<br />

BA<br />

BT<br />

xx<br />

Flying leads<br />

Flying leads with light<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

EBM34A-xxxx-xx<br />

Port size<br />

COMMON INLET & EXHAUST<br />

# 10-32<br />

1/8” NPTF<br />

EBM34A-001B-XX<br />

EBM34A-002A-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.11C v , 2.5 W : 0.084C v , 1.8 W : 0.061C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 3.4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve fastening kit : M34001-01 (1/8” Bar); M34001-21 (#10-32 Bar) • Blanking plate : 30456-A.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory.<br />

DIMENSIONS<br />

19,0<br />

2<br />

B<br />

1<br />

3<br />

A<br />

G<br />

D<br />

10,5<br />

E<br />

14,0<br />

F<br />

C<br />

38,5<br />

Port size<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

1/8”<br />

16.0<br />

47.5<br />

57.4<br />

8.0<br />

23.0<br />

31.0<br />

8.0<br />

M5<br />

12.0<br />

43.5<br />

51.5<br />

9.0<br />

18.0<br />

26.0<br />

6.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v plug-in<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

ECD034B-00xxx-AOxx<br />

Port size<br />

Side cylinder ports<br />

(10.5 mm)<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

M5<br />

ECD034B-001AD-AOXX<br />

ECD034B-002AD-AOXX<br />

# 10-32<br />

ECD034B-001AB-AOXX<br />

ECD034B-002AB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector option (9, 15 or 25).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

32.0<br />

TYP<br />

20.0<br />

8.3<br />

TYP<br />

29.5<br />

14.7<br />

TYP<br />

3<br />

TYP<br />

83.8<br />

57.2<br />

1<br />

77.0<br />

TYP<br />

2 2 2 2<br />

23.3<br />

10.5<br />

60.80<br />

22.3<br />

25.5<br />

TYP<br />

2 2 2 2<br />

10.0<br />

24.8<br />

10.5<br />

4.5<br />

10.0<br />

20.2<br />

22.5<br />

33.0<br />

21.6<br />

23.9<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

55.5<br />

3<br />

66.0<br />

4<br />

76.5<br />

5<br />

87.0<br />

6<br />

97.5<br />

7 8 9 10<br />

108.0 118.5 129.0 139.5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v<br />

plug-in<br />

with F. C.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />

Port size<br />

M5<br />

# 10-32<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECD034B-005AD-AOXX<br />

ECD034B-005AB-AOXX<br />

ECD034B-00xxx-AOxx<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECD034B-006AD-AOXX<br />

ECD034B-006AB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector option (9, 15 or 25).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

32.0<br />

TYP<br />

20.0<br />

8.3<br />

TYP<br />

14.7<br />

TYP<br />

29.5<br />

TYP<br />

3<br />

10.2<br />

83.8<br />

57.2<br />

1<br />

77.0<br />

TYP<br />

2 2 2 2<br />

23.3<br />

22.3<br />

34.40<br />

25.8<br />

TYP<br />

10.5<br />

60.80<br />

10.0<br />

24.8<br />

10.5<br />

4.5<br />

10.0<br />

20.2<br />

2 2 2 2<br />

22.5<br />

33.0<br />

21.6<br />

23.9<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

55.5<br />

3<br />

66.0<br />

4<br />

76.5<br />

5<br />

87.0<br />

6<br />

97.5<br />

7 8 9 10<br />

108.0 118.5 129.0 139.5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v<br />

plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />

ECD034B-00xxx-AOxx<br />

Port size<br />

M5<br />

# 10-32<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECD034B-004AD-AOXX<br />

ECD034B-004AB-AOXX<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECD034B-003AD-AOXX<br />

ECD034B-003AB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector option (9, 15 or 25).<br />

** Pressure Regulators :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Blanking plate for regulator : N-44003. • Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

40.00<br />

L<br />

32.0<br />

TYP<br />

24.8<br />

10.5<br />

20.2<br />

8.3<br />

TYP<br />

144.1<br />

14.7<br />

TYP<br />

29.5<br />

3<br />

2 2 2 2<br />

23.3<br />

TYP<br />

83.8<br />

57.2<br />

1<br />

22.3<br />

77.0<br />

TYP<br />

10.0<br />

4.5<br />

10.0<br />

10.5<br />

20.0<br />

60.80<br />

25.8<br />

TYP<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

2 2 2 2<br />

22.5<br />

33.0<br />

21.6<br />

23.9<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

55.5<br />

3<br />

66.0<br />

4<br />

76.5<br />

5<br />

87.0<br />

6<br />

97.5<br />

7 8 9 10<br />

108.0 118.5 129.0 139.5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.09C v<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

ECD034B-00xxx-AOxx<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS ** (pressure regulators to be ordered separately)<br />

Port size<br />

M5<br />

# 10-32<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECD034B-007AD-AOXX<br />

ECD034B-007AB-AOXX<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECD034B-008AD-AOXX<br />

ECD034B-008AB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector option (9, 15 or 25).<br />

** Pressure Regulators :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180. • Blanking plate for regulator : N-44003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

40.00<br />

L<br />

32.0<br />

TYP<br />

24.8<br />

10.5<br />

20.2<br />

8.3<br />

TYP<br />

144.1<br />

29.5<br />

14.7<br />

TYP<br />

3<br />

2 2 2 2<br />

23.3<br />

TYP<br />

83.8<br />

57.2<br />

1<br />

22.3<br />

77.0<br />

TYP<br />

10.0<br />

4.5<br />

10.0<br />

10.5<br />

20.0<br />

60.80<br />

25.8<br />

TYP<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

2 2 2 2<br />

22.5<br />

33.0<br />

21.6<br />

23.9<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

55.5<br />

3<br />

66.0<br />

4<br />

76.5<br />

5<br />

87.0<br />

6<br />

97.5<br />

7 8 9 10<br />

108.0 118.5 129.0 139.5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v<br />

add-on style<br />

plug-in<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

ECD034B-00xxx-AOxx<br />

Port size<br />

Side cylinder ports<br />

(10.5 mm)<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

M5<br />

ECD034B-001BD-AOXX<br />

ECD034B-002BD-AOXX<br />

# 10-32<br />

ECD034B-001BB-AOXX<br />

ECD034B-002BB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector option (9, 15 or 25).<br />

add-a-unit stations may be added to above bars. Clic here for model numbers.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

32.0<br />

20.0<br />

8.3<br />

14.8<br />

29.5<br />

3<br />

83.7<br />

57.2<br />

1<br />

77.0<br />

2 2 2 2<br />

15.0<br />

10.5 16.0<br />

15.5<br />

60.8<br />

23.0<br />

22.3<br />

4.5<br />

10.0<br />

25.3<br />

41.3<br />

10.9<br />

25.8<br />

2 2 2 2<br />

20.2<br />

10.5<br />

22.5<br />

33.0<br />

23.0<br />

25.3<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

57.0<br />

3<br />

67.5<br />

4<br />

78.0<br />

5<br />

88.5<br />

6<br />

99.0<br />

7 8 9 10<br />

109.5 120.0 130.5 141.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v<br />

add-on style<br />

plug-in<br />

with F. C.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />

Port size<br />

M5<br />

# 10-32<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECD034B-005BD-AOXX<br />

ECD034B-005BB-AOXX<br />

ECD034B-00xxx-AOxx<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECD034B-006BD-AOXX<br />

ECD034B-006BB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector option (9, 15 or 25).<br />

add-a-unit stations may be added to above bars. Clic here for model numbers.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

32.0<br />

20.0<br />

8.3<br />

14.8<br />

29.5<br />

3<br />

83.7<br />

57.2<br />

1<br />

77.0<br />

2 2 2 2<br />

15.5<br />

15.0<br />

10.5 16.0<br />

60.8<br />

25.8<br />

2 2 2 2<br />

23.0<br />

22.3<br />

4.5<br />

10.0<br />

25.3<br />

41.3<br />

10.9<br />

10.5<br />

20.2<br />

22.5<br />

33.0<br />

23.0<br />

25.3<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

57.0<br />

3<br />

67.5<br />

4<br />

78.0<br />

5<br />

88.5<br />

6<br />

99.0<br />

7 8 9 10<br />

109.5 120.0 130.5 141.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v<br />

add-on style<br />

plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

ECD034B-00xxx-AOxx<br />

HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />

Port size<br />

M5<br />

# 10-32<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECD034B-004BD-AOXX<br />

ECD034B-004BB-AOXX<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECD034B-003BD-AOXX<br />

ECD034B-003BB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector option (9, 15 or 25).<br />

add-a-unit stations may be added to above bars. Clic here for model numbers.<br />

** Pressure Regulators :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180. • Blanking plate for regulator : N-44003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

32.0<br />

L<br />

20.0<br />

20.2 10.5<br />

41.3<br />

25.3<br />

14.8<br />

29.5<br />

57.2<br />

8.3<br />

1<br />

3<br />

83.7<br />

2 2 2 2<br />

77.0<br />

137.3<br />

10.5<br />

15.0<br />

16.0<br />

15.5<br />

60.8<br />

4.5<br />

22.3<br />

23.0 10.0<br />

10.9<br />

25.8<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

2 2 2 2<br />

22.5<br />

33.0<br />

23.0<br />

25.3<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

57.0<br />

3<br />

67.5<br />

4<br />

78.0<br />

5<br />

88.5<br />

6<br />

99.0<br />

7 8 9 10<br />

109.5 120.0 130.5 141.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.09C v<br />

plug-in<br />

with Pr. Reg.<br />

add-on style<br />

<strong>and</strong> F. C.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

ECD034B-00xxx-AOxx<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS ** (pressure regulators to be ordered separately)<br />

Port size<br />

M5<br />

# 10-32<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECD034B-007BD-AOXX<br />

ECD034B-007BB-AOXX<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECD034B-008BD-AOXX<br />

ECD034B-008BB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector option (9, 15 or 25).<br />

add-a-unit stations may be added to above bars. Clic here for model numbers.<br />

** Pressure Regulators :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Blanking plate for regulator : N-44003. • Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

32.0<br />

20.0<br />

20.2<br />

10.5<br />

41.3<br />

25.3<br />

14.8<br />

29.5<br />

57.2<br />

8.3<br />

83.7<br />

1<br />

3<br />

2 2 2 2<br />

77.0<br />

137.3<br />

15.5<br />

23.0<br />

22.3<br />

10.0<br />

4.5<br />

10.9<br />

15.0<br />

10.5 16.0<br />

60.8<br />

25.8<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

2 2 2 2<br />

22.5<br />

33.0<br />

23.0<br />

25.3<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

57.0<br />

3<br />

67.5<br />

4<br />

78.0<br />

5<br />

88.5<br />

6<br />

99.0<br />

7 8 9 10<br />

109.5 120.0 130.5 141.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v<br />

plug-in<br />

add-a-unit<br />

stations<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

ECD034B-00xxx-AOxx<br />

Port size<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

M5<br />

ECD034B-001CD-AOXX<br />

ECD034B-002CD-AOXX<br />

# 10-32<br />

ECD034B-001CB-AOXX<br />

ECD034B-002CB-AOXX<br />

Number of stations (03=3 stations) - Maximum length is 4 stations<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

when add-a-unit stations are added to bars with a multi-pin connector,<br />

MOD. SD03 should be included with add-a-unit model number.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

32.0<br />

20.0<br />

8.3<br />

14.8<br />

29.5<br />

3<br />

83.7<br />

57.2<br />

1<br />

77.0<br />

2 2 2 2<br />

15.0<br />

10.5 16.0<br />

15.5<br />

60.8<br />

23.0<br />

22.3<br />

4.5<br />

10.0<br />

25.3<br />

41.3<br />

10.9<br />

25.8<br />

2 2 2 2<br />

20.2<br />

10.5<br />

22.5<br />

33.0<br />

23.0<br />

25.3<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

57.0<br />

3<br />

67.5<br />

4<br />

78.0<br />

5<br />

88.5<br />

6<br />

99.0<br />

7 8 9 10<br />

109.5 120.0 130.5 141.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v<br />

add-a-unit<br />

stations with<br />

plug-in<br />

F. C.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />

Port size<br />

Side cylinder ports<br />

ECD034B-00xxx-AOxx<br />

Bottom cylinder ports<br />

M5<br />

# 10-32<br />

ECD034B-005CD-AOXX<br />

ECD034B-005CB-AOXX<br />

ECD034B-006CD-AOXX<br />

ECD034B-006CB-AOXX<br />

Number of stations (03=3 stations) - Maximum length is 4 stations<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

when add-a-unit stations are added to bars with a multi-pin connector,<br />

MOD. SD03 should be included with add-a-unit model number.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

32.0<br />

20.0<br />

8.3<br />

14.8<br />

29.5<br />

3<br />

83.7<br />

57.2<br />

1<br />

77.0<br />

2 2 2 2<br />

15.5<br />

15.0<br />

10.5 16.0<br />

60.8<br />

25.8<br />

2 2 2 2<br />

23.0<br />

22.3<br />

4.5<br />

10.0<br />

25.3<br />

41.3<br />

10.9<br />

10.5<br />

20.2<br />

22.5<br />

33.0<br />

23.0<br />

25.3<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

57.0<br />

3<br />

67.5<br />

4<br />

78.0<br />

5<br />

88.5<br />

6<br />

99.0<br />

7 8 9 10<br />

109.5 120.0 130.5 141.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v<br />

add-a-unit<br />

stations<br />

plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DD 24VDC (2.5 W)<br />

DF 24VDC (4.0 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />

DJ Plug-in<br />

DT Plug-in with light<br />

DE Plug-in with suppression diode<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

ECD034B-00xxx-AOxx<br />

Port size<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

M5<br />

# 10-32<br />

ECD034B-003CD-AOXX<br />

ECD034B-003CB-AOXX<br />

ECD034B-004CD-AOXX<br />

ECD034B-004CB-AOXX<br />

Number of stations (03=3 stations) - Maximum length is 4 stations<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

when add-a-unit stations are added to bars with a multi-pin connector,<br />

MOD. SD03 should be included with add-a-unit model number.<br />

** Regulator ordered separately-see below<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180. • Blanking plate for regulator : N-44003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

32.0<br />

L<br />

20.0<br />

20.2 10.5<br />

41.3<br />

25.3<br />

14.8<br />

29.5<br />

57.2<br />

8.3<br />

1<br />

3<br />

83.7<br />

2 2 2 2<br />

77.0<br />

137.3<br />

10.5<br />

15.0<br />

16.0<br />

15.5<br />

60.8<br />

4.5<br />

22.3<br />

23.0 10.0<br />

10.9<br />

25.8<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

2 2 2 2<br />

22.5<br />

33.0<br />

23.0<br />

25.3<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

57.0<br />

3<br />

67.5<br />

4<br />

78.0<br />

5<br />

88.5<br />

6<br />

99.0<br />

7 8 9 10<br />

109.5 120.0 130.5 141.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v<br />

add-a-unit<br />

stations with<br />

plug-in<br />

F. C. <strong>and</strong> Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ Plug-in<br />

DD 24VDC (2.5 W)<br />

DT Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE Plug-in with suppression diode<br />

xx Other Options<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

ECD034B-00xxx-AOxx<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS ** (pressure regulators to be ordered separately)<br />

Port size<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

M5<br />

# 10-32<br />

ECD034B-008CD-AOXX<br />

ECD034B-008CB-AOXX<br />

ECD034B-007CD-AOXX<br />

ECD034B-007CB-AOXX<br />

Number of stations (03=3 stations) - Maximum length is 4 stations<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

when add-a-unit stations are added to bars with a multi-pin connector,<br />

MOD. SD03 should be included with add-a-unit model number.<br />

** Regulator ordered separately-see below<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Blanking plate for regulator : N-44003. • Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

32.0<br />

20.0<br />

20.2<br />

10.5<br />

41.3<br />

25.3<br />

14.8<br />

29.5<br />

57.2<br />

8.3<br />

83.7<br />

1<br />

3<br />

2 2 2 2<br />

77.0<br />

137.3<br />

15.5<br />

23.0<br />

22.3<br />

10.0<br />

4.5<br />

10.9<br />

15.0<br />

10.5 16.0<br />

60.8<br />

25.8<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

2 2 2 2<br />

22.5<br />

33.0<br />

23.0<br />

25.3<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

57.0<br />

3<br />

67.5<br />

4<br />

78.0<br />

5<br />

88.5<br />

6<br />

99.0<br />

7 8 9 10<br />

109.5 120.0 130.5 141.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32, 0.11C v<br />

4mm tube receptacle<br />

plug-in with<br />

pre-wired<br />

connector<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

ECF34B-00xxx-xxxx<br />

Port size<br />

Side cylinder ports<br />

(10.5 mm)<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

M5<br />

ECF34B-00ADA-ZZXX<br />

ECF34B-00BDA-ZZXX<br />

# 10-32<br />

ECF34B-00ABA-ZZXX<br />

ECF34B-00BBA-ZZXX<br />

4 mm tube receptacle<br />

ECF34B-00AEA-ZZXX<br />

---------<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

ZZ Connector<br />

LA 9 Pin Sub D*<br />

LB 15 Pin Sub D*<br />

LC 25 Pin Sub D*<br />

LD 10 Pin Ribbon Cable**<br />

LE 16 Pin Ribbon Cable**<br />

LF 20 Pin Ribbon Cable**<br />

LG 26 Pin Ribbon Cable**<br />

LH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

L=Left Side; R=Right Side<br />

ZZ Connector<br />

RA 9 Pin Sub D*<br />

RB 15 Pin Sub D*<br />

RC 25 Pin Sub D*<br />

RD 10 Pin Ribbon Cable**<br />

RE 16 Pin Ribbon Cable**<br />

RF 20 Pin Ribbon Cable**<br />

RG 26 Pin Ribbon Cable**<br />

RH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

* MIL. Spec; MIL-C-24308<br />

** MIL. Spec; MIL-C-83503<br />

Note: Left <strong>and</strong> right end is determined by facing conduit passage.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

72.6<br />

9.0<br />

17.4<br />

16.7<br />

3<br />

37.9<br />

1<br />

20.0<br />

10.5 13.0<br />

5.0<br />

26.8<br />

53.5 2 2 2<br />

51.6<br />

88.7<br />

2<br />

20.2<br />

10.5<br />

10.0<br />

2 2 2<br />

2<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32, 0.11C v<br />

4mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

plug-in with<br />

F. C. <strong>and</strong><br />

pre-wired<br />

connector<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />

Port size<br />

M5<br />

# 10-32<br />

4 mm tube receptacle<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECF34B-00CDA-ZZXX<br />

ECF34B-00CBA-ZZXX<br />

ECF34B-00CEA-ZZXX<br />

ECF34B-00xxx-xxxx<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECF34B-00DDA-ZZXX<br />

ECF34B-00DBA-ZZXX<br />

---------<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

ZZ Connector<br />

LA 9 Pin Sub D*<br />

LB 15 Pin Sub D*<br />

LC 25 Pin Sub D*<br />

LD 10 Pin Ribbon Cable**<br />

LE 16 Pin Ribbon Cable**<br />

LF 20 Pin Ribbon Cable**<br />

LG 26 Pin Ribbon Cable**<br />

LH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

L=Left Side; R=Right Side<br />

ZZ Connector<br />

RA 9 Pin Sub D*<br />

RB 15 Pin Sub D*<br />

RC 25 Pin Sub D*<br />

RD 10 Pin Ribbon Cable**<br />

RE 16 Pin Ribbon Cable**<br />

RF 20 Pin Ribbon Cable**<br />

RG 26 Pin Ribbon Cable**<br />

RH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

* MIL. Spec; MIL-C-24308<br />

** MIL. Spec; MIL-C-83503<br />

Note: Left <strong>and</strong> right end is determined by facing conduit passage.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.11C v , 2.5 W : 0.09C v , 1.8 W : 0.06C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

9.0 17.4<br />

16.7<br />

3<br />

80.1<br />

37.9<br />

1<br />

20.0<br />

10.5<br />

13.0<br />

5.0<br />

26.8<br />

53.5<br />

88.7<br />

51.6<br />

2 2<br />

2<br />

2<br />

20.2 10.5<br />

10.0<br />

2<br />

2<br />

2<br />

2<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32 0.10C v<br />

Pr. Reg. <strong>and</strong><br />

pre-wired<br />

plug-in with<br />

connector<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />

Port size<br />

M5<br />

# 10-32<br />

ECF34B-00xxx-xxxx<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECF34B-00EDA-ZZXX<br />

ECF34B-00EBA-ZZXX<br />

Number of stations (03=3 stations)<br />

** Pressure Regulators :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

ZZ<br />

Connector<br />

LA 9 Pin Sub D*<br />

LB 15 Pin Sub D*<br />

LC 25 Pin Sub D*<br />

LD 10 Pin Ribbon Cable**<br />

LE 16 Pin Ribbon Cable**<br />

LF 20 Pin Ribbon Cable**<br />

LG 26 Pin Ribbon Cable**<br />

LH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

L=Left Side; R=Right Side<br />

ZZ Connector<br />

RA 9 Pin Sub D*<br />

RB 15 Pin Sub D*<br />

RC 25 Pin Sub D*<br />

RD 10 Pin Ribbon Cable**<br />

RE 16 Pin Ribbon Cable**<br />

RF 20 Pin Ribbon Cable**<br />

RG 26 Pin Ribbon Cable**<br />

RH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

* MIL. Spec; MIL-C-24308<br />

** MIL. Spec; MIL-C-83503<br />

Note: Left <strong>and</strong> right end is determined by facing conduit passage.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10C v , 2.5 W : 0.09C v , 1.8 W : 0.07C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Blanking plate for regulator : N-44003. • Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

132.9<br />

9.0 17.4<br />

16.7<br />

3<br />

1<br />

37.9<br />

20.0<br />

5.0<br />

26.8<br />

53.5<br />

88.7<br />

51.6<br />

2 2<br />

2<br />

2<br />

K<br />

O C<br />

L<br />

K<br />

O C<br />

L<br />

K<br />

O C<br />

L<br />

K<br />

O C<br />

L<br />

2<br />

-<br />

+<br />

-<br />

+<br />

-<br />

+<br />

-<br />

+<br />

10.5<br />

13.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32, 0.11C v<br />

4mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

din rail,<br />

plug-in with<br />

pre-wired<br />

connector<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

ECF34B-00xxx-xxxx<br />

Port size<br />

M5<br />

# 10-32<br />

4 mm tube receptacle<br />

Number of stations (03=3 stations)<br />

Din rail spec. (EN50 022)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

ZZ<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECF34B-00ADB-ZZXX<br />

ECF34B-00ABB-ZZXX<br />

ECF34B-00AEB-ZZXX<br />

Connector<br />

LA 9 Pin Sub D*<br />

LB 15 Pin Sub D*<br />

LC 25 Pin Sub D*<br />

LD 10 Pin Ribbon Cable**<br />

LE 16 Pin Ribbon Cable**<br />

LF 20 Pin Ribbon Cable**<br />

LG 26 Pin Ribbon Cable**<br />

LH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

L=Left Side; R=Right Side<br />

ZZ Connector<br />

RA 9 Pin Sub D*<br />

RB 15 Pin Sub D*<br />

RC 25 Pin Sub D*<br />

RD 10 Pin Ribbon Cable**<br />

RE 16 Pin Ribbon Cable**<br />

RF 20 Pin Ribbon Cable**<br />

RG 26 Pin Ribbon Cable**<br />

RH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

* MIL. Spec; MIL-C-24308<br />

** MIL. Spec; MIL-C-83503<br />

Note: Left <strong>and</strong> right end is determined by facing conduit passage.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


2<br />

3<br />

1<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.11C v , 2.5 W : 0.09C v , 1.8 W : 0.06C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

72.6<br />

9.0<br />

17.4<br />

3<br />

16.7<br />

1<br />

37.9<br />

VAC TO 120 PSI<br />

ELECTRICAL WATTS<br />

MODEL<br />

WIXOM,MI.USA<br />

LIEGE,BELGIUM<br />

AUCKLAND,N.Z.<br />

20.0<br />

5.0<br />

MODIF.<br />

53.5<br />

88.7<br />

60.9<br />

20.2<br />

10.5<br />

10.0<br />

2 2 2 2<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 34<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC M5 - #10-32, 0.11C v<br />

4 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

din rail,<br />

plug-in with<br />

F. C. <strong>and</strong> prewired<br />

connector<br />

HOW TO ORDER<br />

34B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

34B-LOO-GXXO-XXX<br />

1 3<br />

34B-NOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DJ<br />

Plug-in<br />

DD 24VDC (2.5 W)<br />

DT<br />

Plug-in with light<br />

DF 24VDC (4.0 W)<br />

DE<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

DV<br />

xx<br />

Plug-in with light <strong>and</strong> suppression diode<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />

Port size<br />

M5<br />

# 10-32<br />

4 mm tube receptacle<br />

Number of stations (03=3 stations)<br />

Din rail spec. (EN50 022)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

ZZ<br />

ECF34B-00xxx-xxxx<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECF34B-00CDB-ZZXX<br />

ECF34B-00CBB-ZZXX<br />

ECF34B-00CEB-ZZXX<br />

Connector<br />

LA 9 Pin Sub D*<br />

LB 15 Pin Sub D*<br />

LC 25 Pin Sub D*<br />

LD 10 Pin Ribbon Cable**<br />

LE 16 Pin Ribbon Cable**<br />

LF 20 Pin Ribbon Cable**<br />

LG 26 Pin Ribbon Cable**<br />

LH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

L=Left Side; R=Right Side<br />

ZZ Connector<br />

RA 9 Pin Sub D*<br />

RB 15 Pin Sub D*<br />

RC 25 Pin Sub D*<br />

RD 10 Pin Ribbon Cable**<br />

RE 16 Pin Ribbon Cable**<br />

RF 20 Pin Ribbon Cable**<br />

RG 26 Pin Ribbon Cable**<br />

RH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

* MIL. Spec; MIL-C-24308<br />

** MIL. Spec; MIL-C-83503<br />

Note: Left <strong>and</strong> right end is determined by facing conduit passage.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


2<br />

3<br />

1<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 34<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.11C v , 2.5 W : 0.09C v , 1.8 W : 0.06C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16595. • Mounting screw (x2) : 35031. • Blanking plate : M-34005.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

9.0 17.4<br />

80.1<br />

16.7<br />

3<br />

1<br />

37.9<br />

VAC TO 120 PSI<br />

ELECTRICAL<br />

WATTS<br />

MODEL<br />

WIXOM,MI.USA MODIF.<br />

LIEGE,BELGIUM<br />

AUCKLAND,N.Z.<br />

20.0<br />

5.0<br />

53.5<br />

88.7<br />

60.9<br />

20.2 10.5<br />

10.0<br />

2<br />

2<br />

2<br />

2<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Section 2 Options<br />

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Codification table for voltages / Manual operator / Electrical connection<br />

VALVE CODE ➤<br />

- G XX X - X XX<br />

1 2 3 4<br />

OPTIONS AVAILABLE FOR<br />

- solenoid valves 34 & 44 Series<br />

Consult “Precautions”before use, installation or service of MAC Valves.


OPTIONS<br />

Back<br />

1. VOLTAGE (type 34 Series)<br />

-G XX X - X XX VOLTAGE<br />

DC 24 VDC (1,8 W)<br />

DD 24 VDC (2,5 W)<br />

DE 24 VDC (3,0 W)<br />

DF 24 VDC (4,0 W)<br />

DJ 12 VDC (1,8 W)<br />

DK 12 VDC (2,5 W)<br />

DM 12 VDC (3,0 W)<br />

DN 12 VDC (4,0 W)<br />

1. VOLTAGE (type 44 Series)<br />

-G XX X - X XX VOLTAGE<br />

DA 24 VDC (1,0 W)<br />

DC 24 VDC (1,8 W)<br />

DD 24 VDC (2,5 W)<br />

DF 24 VDC (4,0 W)<br />

DG 12 VDC (1,0 W)<br />

DJ 12 VDC (1,8 W)<br />

DK 12 VDC (2,5 W)<br />

DN 12 VDC (4,0 W)<br />

2. WIRE LENGTH (Common options for 34 & 44 Series)<br />

-G XX X - X XX WIRE LENGTH<br />

A 18”<br />

B 24”<br />

C 36”<br />

D 48”<br />

E 72”<br />

F 96”<br />

G 120”<br />

H 144”<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Back<br />

3. MANUAL OPERATOR (COMMON OPTIONS FOR 34 & 44 SERIES)<br />

-G XX X - X XX MANUAL OPERATOR<br />

1 Non-locking recessed<br />

3 Non-locking extended<br />

4. ELECTRICAL CONNECTION (COMMON OPTIONS FOR 34 & 44 SERIES)<br />

-G XX X - X XX NO CONNECTOR<br />

BA Flying leads<br />

BB BA with ground wire<br />

BC BA with light<br />

BD BA with light <strong>and</strong> ground wire<br />

BE BA with suppression diode<br />

BF BA with suppression diode <strong>and</strong> ground wire<br />

BG BA with suppression diode <strong>and</strong> light<br />

BH BA with suppression diode, light <strong>and</strong> ground wire<br />

BN BA with suppression diode <strong>and</strong> blocking diode<br />

BP BA with suppression diode, blocking diode <strong>and</strong> ground wire<br />

BR BA with suppression diode, blocking diode <strong>and</strong> light<br />

BS BA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />

BT BA with light<br />

BU BA with light <strong>and</strong> ground wire<br />

BV BA with suppression diode <strong>and</strong> light<br />

BW BA with suppression diode, light <strong>and</strong> ground wire<br />

BX BA with suppression diode, blocking diode <strong>and</strong> light<br />

BY BA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />

-G XX X - X XX PLUG-IN CONNECTOR<br />

KA Mini connector with flying leads<br />

KB KA with ground wire<br />

KE KA with suppression diode<br />

KF KA with suppression diode <strong>and</strong> ground wire<br />

KJ Mini connector for KA option<br />

KM Mini connector for KB option<br />

KN KA with suppression diode <strong>and</strong> blocking diode<br />

KP KA with suppression diode, blocking diode <strong>and</strong> ground wire<br />

KT KA with light<br />

KU KA with light <strong>and</strong> ground wire<br />

KV KA with suppression diode <strong>and</strong> light<br />

KW KA with suppression diode, light <strong>and</strong> ground wire<br />

KX KA with suppression diode, blocking diode <strong>and</strong> light<br />

KY KA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

PIN #6<br />

PIN #9<br />

MOD. SD09<br />

PIN #1<br />

PIN #5<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 9<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 7 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 2 common wires<br />

PIN #9<br />

PIN #15<br />

MOD. SD15<br />

PIN #1<br />

PIN #8<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 15<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 12 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 3 common wires<br />

PIN #14<br />

PIN #25<br />

MOD. SD25<br />

PIN #1<br />

PIN #13<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 25<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 20 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 5 common wires<br />

Note : Use desired MOD. number after circuit bar part number


O p t i o n s<br />

OPTIONS<br />

Connector termination details<br />

CONNECTOR<br />

SOL 1<br />

SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />

Single solenoid circuit bar<br />

SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />

CONNECTOR<br />

SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />

Double solenoid circuit bar<br />

SD09 SD15 SD25<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

8<br />

COMMON (+)<br />

13<br />

COMMON (+)<br />

21<br />

COMMON (+)<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

9<br />

COMMON (+)<br />

8<br />

SOL. 8<br />

8<br />

SOL. 8<br />

14<br />

COMMON (+)<br />

22<br />

COMMON (+)<br />

9<br />

SOL. 9<br />

9<br />

SOL. 9<br />

10 SOL. 10<br />

10 SOL. 10<br />

11<br />

SOL. 11<br />

11<br />

SOL. 11<br />

12 SOL. 12<br />

12 SOL. 12<br />

15<br />

COMMON (+)<br />

23<br />

COMMON (+)<br />

13<br />

SOL. 13<br />

14 SOL. 14<br />

15<br />

SOL. 15<br />

16 SOL. 16<br />

24<br />

COMMON (+)<br />

17<br />

18 SOL. 18<br />

19<br />

20 SOL. 20<br />

SOL. 17<br />

SOL. 19<br />

25<br />

COMMON (+)


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 35<br />

Circuit bar mounting<br />

non plug-in<br />

non plug-in<br />

with Pr. Reg.<br />

plug-in<br />

plug-in<br />

with side<br />

Pr. Reg.<br />

plug-in<br />

with integral<br />

terminal strip<br />

plug-in with<br />

integral terminal<br />

strip <strong>and</strong> side<br />

Pr. Reg.<br />

Manual operator<br />

Armature<br />

Epoxy encapsulated solenoid<br />

Push pin<br />

Spring biased moveable pole piece<br />

1<br />

Bonded balanced poppet<br />

CYL.<br />

PORT<br />

2<br />

N.C.<br />

PORT<br />

Spring return<br />

3<br />

SERIES FEATURES<br />

• Patented MACSOLENOID ® for fastest possible response times.<br />

• Balanced poppet permits versatility in function :<br />

- 3 way N.C. - 3 way N.O. - Divertor - Selector<br />

• Extremely high cycle rate capability.<br />

• Various solenoid enclosures <strong>and</strong> plug-in connectors.<br />

• Low wattage DC solenoids - down to 1.8 watts.<br />

• Rated for lubricated or non-lubricated service.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 35<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v non plug-in<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

35A-xxx-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Universal valve<br />

CYL<br />

Valve less base<br />

IN EXH<br />

35A-B00-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

AA 120/60, 110/50<br />

A<br />

18” (Flying leads)<br />

1 Non-locking Recessed<br />

KA<br />

Square connector<br />

AB 240/60, 220/50<br />

J<br />

Connector<br />

2 Locking Recessed<br />

KD<br />

Square connector<br />

with light<br />

AC 24/60, 24/50<br />

x<br />

Other Options<br />

x<br />

Other Options<br />

BA<br />

Flying leads<br />

FB 24VDC (1.8 W)<br />

xx<br />

Other Options<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR**<br />

Port size<br />

1/8” NPTF<br />

# 10-32 UNF<br />

EBM35A-xxxx-xx<br />

Side cylinder ports<br />

Spacing 21 mm<br />

EBM35A-001A-XX<br />

EBM35A-001B-XX<br />

Bottom cylinder ports<br />

Spacing 21 mm<br />

EBM35A-002A-XX<br />

EBM35A-002B-XX<br />

Number of stations (03=3 stations)<br />

* * Other options available. Consult factory.<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 35<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

VALVE BLANKING<br />

PLATE<br />

21,0<br />

"A"<br />

21,0<br />

5,2 DIA.<br />

2 MTG. HOLES<br />

D<br />

7,0<br />

21,0<br />

5,0<br />

OPTIONAL<br />

BOTTOM PORTS<br />

5,0<br />

29,5<br />

2 2<br />

5,0<br />

B<br />

64,5<br />

32,5<br />

26,3<br />

50,5<br />

22,0<br />

11,5<br />

SPACING SIZE<br />

A<br />

17,0<br />

32,0<br />

40,0<br />

1/8” 2 PORTS<br />

BOTH ENDS<br />

STANDARD<br />

FOR JB<br />

SPACING SIZE<br />

21.0<br />

26.0<br />

B D<br />

1/8”<br />

# 10-32<br />

8.0<br />

5.5<br />

24.5<br />

24.2<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 35<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v<br />

non plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

35A-xxx-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Universal valve<br />

CYL<br />

Valve less base<br />

Valve less base w/ gage port<br />

IN EXH<br />

35A-B00-DXXX-XXX<br />

35A-F00-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

AA 120/60, 110/50<br />

A<br />

18” (Flying leads)<br />

1 Non-locking Recessed<br />

KA<br />

Square connector<br />

AB 240/60, 220/50<br />

J<br />

Connector<br />

2 Locking Recessed<br />

KD<br />

Square connector<br />

with light<br />

AC 24/60, 24/50<br />

x<br />

Other Options<br />

x<br />

Other Options<br />

BA<br />

Flying leads<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

xx<br />

Other Options<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

EBM35A-xxxx-xx<br />

HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY)* *<br />

Port size<br />

Side cylinder ports<br />

Spacing 21 mm<br />

Spacing 40 mm<br />

1/8” NPTF<br />

# 10-32 UNF<br />

Port size<br />

Bottom cylinder ports<br />

EBM35A-003A-XX<br />

EBM35A-003B-XX<br />

Spacing 21 mm<br />

EBM35A-023A-XX<br />

EBM35A-023B-XX<br />

Spacing 40 mm<br />

1/8” NPTF<br />

# 10-32 UNF<br />

EBM35A-004A-XX<br />

EBM35A-004B-XX<br />

EBM35A-024A-XX<br />

EBM35A-024B-XX<br />

Number of stations (03=3 stations)<br />

Other options available. Consult factory.<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

use 40 mm spacing for valves w/ gage port.<br />

** Pressure Regulators :<br />

35A-00M (Adjusting knob)<br />

35A-00L (Slotted stem)<br />

35A-00U (Locking stem)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 35<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

VALVE BLANKING<br />

PLATE<br />

B<br />

5 5<br />

5,2 DIA<br />

2 MTG. HOLES<br />

21,0 "A" 21,0<br />

21<br />

5<br />

35,5<br />

2 2<br />

1/8” 2 PORTS<br />

BOTH ENDS<br />

REGULATOR<br />

BLANKING PLATE<br />

8,0 58,3<br />

5,0<br />

32,5<br />

20,1<br />

47,5<br />

56,5<br />

28,0<br />

17,75<br />

14,0 16,0<br />

SPACING SIZE<br />

A<br />

OPTIONAL<br />

BOTTOM PORTS<br />

10,5<br />

25,5<br />

40,0<br />

91,1<br />

STANDARD<br />

FOR GAGES<br />

PORT SIZE<br />

B<br />

21.0<br />

40.0<br />

1/8”<br />

15.5<br />

# 10-32<br />

18.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 35<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v plug-in<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

35A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR "PLUG-IN" CIRCUIT BAR<br />

Universal valve<br />

CYL<br />

Valve less base<br />

IN EXH<br />

35A-B00-DXXJ-XFM<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

HOW TO ORDER "PLUG-IN" CIRCUIT BAR **<br />

ECD35A-xxxx-xx-xx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

21<br />

ECD35A-001A-A0-XX*<br />

ECD35A-002A-A0-XX*<br />

# 10-32 UNF<br />

21<br />

ECD35A-001B-A0-XX*<br />

ECD35A-002B-A0-XX*<br />

1/8” NPTF<br />

30<br />

ECD35A-031A-C0-XX*<br />

ECD35A-032A-C0-XX*<br />

# 10-32 UNF<br />

30<br />

ECD35A-031B-C0-XX*<br />

ECD35A-032B-C0-XX*<br />

Number of stations (03=3 stations)<br />

* * Other options available. Consult factory.<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector (9, 15 or 25).<br />

* A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal w/light (120V)<br />

CB = terminal w/light (240V)<br />

CD = terminal w/light (24V)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 35<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004. • Plug-in protector : 16520.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

VALVE BLANKING<br />

PLATE<br />

21,0<br />

“A” 21,0<br />

21,0<br />

22,8<br />

61,0<br />

5,1<br />

17<br />

68,5<br />

47,5<br />

2<br />

2<br />

30,0<br />

19,8<br />

17,0 20,0<br />

40<br />

13,5<br />

5,0<br />

37,0<br />

1/8” PORTS<br />

1 & 3 EACH END<br />

29,0<br />

57,3<br />

1" NPSM<br />

EACH END<br />

4,5<br />

78,0<br />

84,8<br />

2<br />

4,5<br />

5,2 DIA. (2) MOUNT-<br />

ING HOLES<br />

SPACING SIZE<br />

A<br />

37,0<br />

STANDARD<br />

FOR TERMINAL<br />

STRIPS<br />

21.0<br />

30.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 35<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v<br />

plug-in<br />

with side<br />

Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

35A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR "PLUG-IN" CIRCUIT BAR<br />

Universal valve<br />

CYL<br />

Valve less base<br />

Valve less base w/ gage port<br />

IN EXH<br />

35A-B00-DXXJ-XFM<br />

35A-F00-DXXJ-XFM<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

ECD35A-xxxx-xx-xx<br />

HOW TO ORDER "PLUG-IN" CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY)* *<br />

Port size<br />

1/8” NPTF<br />

# 10-32 UNF<br />

1/8” NPTF<br />

# 10-32 UNF<br />

1/8” NPTF<br />

# 10-32 UNF<br />

Spacing<br />

mm<br />

21<br />

21<br />

30<br />

30<br />

40<br />

40<br />

Bottom cylinder ports<br />

ECD35A-004A-A0-XX*<br />

ECD35A-004B-A0-XX*<br />

ECD35A-034A-C0-XX*<br />

ECD35A-034B-C0-XX*<br />

ECD35A-024A-A0-XX*<br />

ECD35A-024B-A0-XX*<br />

Number of stations (03=3 stations)<br />

* * Other options available. Consult factory.<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector (9, 15 or 25).<br />

minimum spacing for terminal strips is 30 mm.<br />

use 40 mm spacing for valves w/gage port.<br />

** Pressure Regulators :<br />

35A-00M (Adjusting knob)<br />

35A-00L (Slotted stem)<br />

35A-00U (Locking stem)<br />

Consult “Precautions” before use, installation or service of MAC Valves.<br />

* A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal w/light (120V)<br />

CB = terminal w/light (240V)<br />

CD = terminal w/light (24V)


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 35<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004. • Blanking plate regulator : M-35005.<br />

• Plug-in protector : 16520.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

VALVE BLANKING<br />

PLATE<br />

21,0<br />

“A” 21,0<br />

21,0<br />

22,8<br />

61,0<br />

5,1<br />

17,0<br />

68,5<br />

47,5<br />

2<br />

2<br />

30,0<br />

19,8<br />

17,0 20,0<br />

40,0<br />

13,5<br />

5,0<br />

37,0<br />

1/8” PORTS<br />

1 & 3 EACH END<br />

29,0<br />

57,3<br />

1" NPSM<br />

EACH END<br />

4,5<br />

78,0<br />

84,8<br />

5<br />

2<br />

SPACING SIZE<br />

A<br />

13,4 “B”<br />

51,0<br />

4,5<br />

37,0<br />

20,7<br />

5,2 DIA. (2)<br />

MOUNTING HOLES<br />

STANDARD<br />

FOR GAGES<br />

FOR TERMINAL<br />

STRIPS<br />

SPACING SIZE<br />

21.0<br />

40.0<br />

30.0<br />

B<br />

SLOTTED<br />

LOCKING STEM<br />

6.0<br />

ADJUSTING KNOB<br />

13.4<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 35<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v<br />

plug-in<br />

with integral<br />

terminal strip<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

35A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR "PLUG-IN" CIRCUIT BAR<br />

Universal valve<br />

CYL<br />

Valve less base<br />

IN EXH<br />

35A-B00-DXXJ-XFM<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

HOW TO ORDER "PLUG-IN" CIRCUIT BAR **<br />

ECE35A-xxxx-xx-xx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

26<br />

ECE35A-011A-C0-XX*<br />

ECE35A-012A-C0-XX*<br />

# 10-32 UNF<br />

26<br />

ECE35A-011B-C0-XX*<br />

ECE35A-012B-C0-XX*<br />

Number of stations (03=3 stations)<br />

* * Other options available. Consult factory.<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

end plate kit required: M-45017.<br />

* C0 = terminal strip<br />

CA = terminal strip w/light (120V)<br />

CB = terminal strip w/light (240V)<br />

CD = terminal strip w/light (24V)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 35<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004. • Plug-in protector : 16520.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

16.0<br />

28.5<br />

26.0<br />

LC<br />

C L<br />

C L<br />

LC<br />

30.0<br />

43.0<br />

68.5<br />

2 2 2 2<br />

1/8" - 27 N.P.T.F.<br />

1/8" - 28 B.S.P.PL.<br />

1/8" - 28 B.S.P.TR.<br />

#10-32<br />

M5 X 0.8<br />

#10-32 GAGE PORT<br />

(OPTIONAL)<br />

LC<br />

C L<br />

C L<br />

C L<br />

1/4"-18 N.P.T.F.<br />

TYP. (2) EACH END<br />

LC<br />

C L<br />

C L<br />

C L<br />

40.0<br />

5.0<br />

EX<br />

2 2<br />

IN<br />

EX<br />

IN<br />

100.4<br />

89.4<br />

58.4<br />

TYP.<br />

MODEL<br />

G<br />

33.9<br />

71.4<br />

79.7<br />

4.5<br />

TYP.<br />

158.0<br />

19.9<br />

28.9<br />

10.9<br />

1"-11 1/2 N.P.S.M.<br />

Note: Bottom & side cylinder ports not available on the same station<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 35<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC 1/8” NPTF - #10-32 UNF 0.10C v<br />

integral terminal<br />

strip <strong>and</strong> side<br />

plug-in with<br />

Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

35A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR "PLUG-IN" CIRCUIT BAR<br />

Universal valve<br />

CYL<br />

Valve less base<br />

Valve less base w/ gage port<br />

IN EXH<br />

35A-B00-DXXJ-XFM<br />

35A-F00-DXXJ-XFM<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

HOW TO ORDER "PLUG-IN" CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY) **<br />

ECE35A-xxxx-xx-xx<br />

Port size<br />

1/8” NPTF<br />

# 10-32 UNF<br />

1/8” NPTF<br />

# 10-32 UNF<br />

Spacing<br />

mm<br />

26<br />

26<br />

40<br />

40<br />

Bottom cylinder ports<br />

ECE35A-014A-C0-XX*<br />

ECE35A-014B-C0-XX*<br />

ECE35A-024A-C0-XX*<br />

ECE35A-024B-C0-XX*<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

use 40 mm spacing for valves w/ gage port.<br />

end plate kit required: M-45017.<br />

** Pressure Regulators :<br />

35A-00M (Adjusting knob)<br />

35A-00L (Slotted stem)<br />

35A-00U (Locking stem)<br />

* C0 = terminal strip<br />

CA = terminal strip w/light (120V)<br />

CB = terminal strip w/light (240V)<br />

CD = terminal strip w/light (24V)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


L O<br />

C K<br />

L O<br />

C K<br />

L O<br />

C K<br />

L O<br />

C K<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 35<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16447.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-35004. • Blanking plate regulator : M-35005.<br />

• Plug-in protector : 16520.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

16.0<br />

28.5<br />

LC<br />

A<br />

C L<br />

C L<br />

LC<br />

43.0<br />

68.5<br />

#10-32 GAGE PORT<br />

(OPTIONAL)<br />

B<br />

LC<br />

C L<br />

C LC<br />

C L<br />

1/4"-18 N.P.T.F.<br />

TYP. (2) EACH END<br />

1/8" - 27 N.P.T.F.<br />

1/8" - 28 B.S.P.PL.<br />

1/8" - 28 B.S.P.TR.<br />

#10-32<br />

M5 X 0.8<br />

LC<br />

C L<br />

C L<br />

C L<br />

EX<br />

2 2<br />

151.4<br />

WITH SIDE<br />

REGULATOR<br />

100.4<br />

IN<br />

IN<br />

EX<br />

89.4<br />

58.4<br />

TYP.<br />

MODEL<br />

G<br />

33.9<br />

71.4<br />

79.7<br />

4.5<br />

TYP.<br />

158.0<br />

19.9<br />

28.9<br />

10.9<br />

1"-11 1/2 N.P.S.M.<br />

Dim.<br />

B<br />

Dim.<br />

5.0<br />

40.0<br />

A<br />

SLOTTED<br />

LOCKING STEM<br />

ADJUSTABLE KNOB<br />

6.0<br />

13.4<br />

STANDARD<br />

SPACING<br />

SPACING<br />

FOR GAUGES<br />

26.0<br />

40.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Section 2 Options<br />

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Codification table for voltages / Wire length / Manual operators / Electrical connections<br />

VALVE CODE ➤<br />

- D XX X - X XX<br />

1 2 3 4<br />

OPTIONS AVAILABLE FOR<br />

- Solenoid valves 35 & 45 Series<br />

Consult “Precautions”before use, installation or service of MAC Valves.


OPTIONS<br />

Back<br />

1. VOLTAGE<br />

- D XX X - X XX VOLTAGE<br />

AD 24/60<br />

AE 200/60<br />

AF 240/50<br />

AG 100/50, 100/60, 110/60<br />

DB 12 VDC (5.4 W)<br />

DC 12 VDC (7.5 W)<br />

DD 24 VDC (7.3 W)<br />

DE<br />

12 VDC (12.7 W) CLSF<br />

DK 110 VDC (5.8 W)<br />

DL 64 VDC (6.0 W)<br />

DM 36 VDC (5.8 W)<br />

DN 6 VDC (6.0 W)<br />

DP 48 VDC (5.8 W)<br />

DU 24 VDC (6.0 W)<br />

EA 12 VDC (6.0 W)<br />

FA 12 VDC (1.8 W)<br />

FE 12 VDC (2.4 W)<br />

FF 24 VDC (2.4 W)<br />

2. WIRE LENGTH<br />

- D XX X - X XX WIRE LENGTH<br />

B 24”<br />

C 36”<br />

D 48”<br />

E 72”<br />

F 96”<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Back<br />

3. MANUAL OPERATOR<br />

- D XX X - X XX MANUAL OPERATOR<br />

0 No operator<br />

1 Non-locking recessed<br />

2 Locking recessed<br />

3 Non-locking extended<br />

4 Locking extended<br />

4. ELECTRICAL CONNECTION<br />

- D XX X - X XX ELECTRICAL CONNECTION<br />

BA Flying leads<br />

BK BA with protection diode<br />

BL BA with protection varistor<br />

CA 1/2" NPS conduit<br />

*FN Plug-in with diode<br />

*FP Plug-in with M.O.V.<br />

JB Rectangular connector<br />

JD Rectangular connector with light<br />

JM Rectangular connector, male only<br />

KA Square connector<br />

KB Square connector with protection diode<br />

KC Square connector with protection varistor<br />

KD Square connector with light<br />

KE Square connector with light <strong>and</strong> protection diode<br />

KF Square connector with light <strong>and</strong> protection varistor<br />

KJ Square connector (male only)<br />

KK Square connector with protection diode (male only)<br />

KL Square connector with protection varistor (male only)<br />

TA Dual tabs<br />

TB TA with protection diode<br />

TD TA with light<br />

TE TA with light <strong>and</strong> protection diode<br />

TJ Dual tabs (male only)<br />

TK TJ with protection diode<br />

TM TJ with light<br />

TN TJ with light <strong>and</strong> protection diode<br />

* For use with the ECD <strong>and</strong> ECE style circuit bars.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

PIN #6<br />

PIN #9<br />

MOD. SD09<br />

PIN #1<br />

PIN #5<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 9<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 7 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 2 common wires<br />

PIN #9<br />

PIN #15<br />

MOD. SD15<br />

PIN #1<br />

PIN #8<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 15<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 12 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 3 common wires<br />

PIN #14<br />

PIN #25<br />

MOD. SD25<br />

PIN #1<br />

PIN #13<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 25<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 20 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 5 common wires<br />

Note : Use desired MOD. number after circuit bar part number


O p t i o n s<br />

OPTIONS<br />

Connector termination details<br />

CONNECTOR<br />

SOL 1<br />

SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />

Single solenoid circuit bar<br />

SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />

CONNECTOR<br />

SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />

Double solenoid circuit bar<br />

SD09 SD15 SD25<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

8<br />

COMMON (+)<br />

13<br />

COMMON (+)<br />

21<br />

COMMON (+)<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

9<br />

COMMON (+)<br />

8<br />

SOL. 8<br />

8<br />

SOL. 8<br />

14<br />

COMMON (+)<br />

22<br />

COMMON (+)<br />

9<br />

SOL. 9<br />

9<br />

SOL. 9<br />

10 SOL. 10<br />

10 SOL. 10<br />

11<br />

SOL. 11<br />

11<br />

SOL. 11<br />

12 SOL. 12<br />

12 SOL. 12<br />

15<br />

COMMON (+)<br />

23<br />

COMMON (+)<br />

13<br />

SOL. 13<br />

14 SOL. 14<br />

15<br />

SOL. 15<br />

16 SOL. 16<br />

24<br />

COMMON (+)<br />

17<br />

18 SOL. 18<br />

19<br />

20 SOL. 20<br />

SOL. 17<br />

SOL. 19<br />

25<br />

COMMON (+)


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Circuit bar mounting<br />

non plug-in<br />

cylinder ports<br />

in valve<br />

non plug-in<br />

cylinder ports<br />

in base<br />

non plug-in<br />

cylinder ports<br />

in base with<br />

Pr. Reg.<br />

non plug-in<br />

add-on style<br />

cylinder ports<br />

in base<br />

non plug-in<br />

add-a-unit<br />

stations<br />

plug-in<br />

plug-in<br />

with Pr. Reg.<br />

add-on style<br />

plug-in<br />

add-on style<br />

plug in<br />

with Pr. Reg.<br />

plug-in<br />

add-a-unit<br />

stations<br />

plug-in<br />

add-a-unit<br />

stations<br />

with Pr. Reg.<br />

Manual operator<br />

Armature<br />

Coil<br />

Push pin<br />

Pole piece<br />

“D” seal<br />

1<br />

Poppet<br />

2<br />

3<br />

Valve return spring<br />

SERIES FEATURES<br />

• Balanced poppet equals consistent high shifting forces.<br />

• Valve shifting forces are consistent <strong>and</strong> independent of pressure fluctuations.<br />

• High solenoid <strong>and</strong> return spring forces ensure high speed <strong>and</strong> precise repeatability.<br />

• Built-in wear compensation - valve stroke is shorter than solenoid stroke.<br />

• Constant high flow maintained throughout the pressure range.<br />

• Exhaust contaminants are isolated from the solenoid.<br />

• Full flow exhaust.<br />

• Universal porting - 6 functions in one valve.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting Profile<br />

non plug-in<br />

26 mm<br />

3/2 NO-NC 1/4” - 3/8” 0.5C v cylinder ports<br />

in valve<br />

38 mm<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Valve port size<br />

Universal valve<br />

NC only valve<br />

2<br />

2<br />

1/8” NPTF<br />

1/4” NPTF<br />

1 3<br />

37A-EGO-HXXX-XXX<br />

37A-EHO-HXXX-XXX<br />

1 3<br />

37A-FGO-HXXX-XXX<br />

37A-FHO-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

A 18”<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

DA 24VDC (5.2 W)<br />

x Other Options<br />

AA 120VAC (must use with<br />

rectified connector)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />

1 Non-locking<br />

MA Plug-in wire assy<br />

MC Plug-in wire assy<br />

with light<br />

BA Flying leads<br />

BC Flying leads with light<br />

HA Plug-in connector with<br />

rectifier <strong>and</strong> light<br />

xx Other Options<br />

EBM37A-xxxxx-xx<br />

Port size<br />

COMMON INLET & EXHAUST<br />

Without regulators (20mm)<br />

With regulators (20mm)<br />

26mm Profile<br />

1/4” NPTF<br />

EBM37A-01CAK-XX<br />

-<br />

38mm Profile<br />

3/8” NPTF<br />

-<br />

EBM37A-01JAK-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

** Pressure Regulators :<br />

PR37A-GOAx<br />

X=A (0 to 120 PSI)<br />

X=B (0 to 80 PSI)<br />

X=C (0 to 30 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37002.<br />

• Regulator blanking plate : R-47003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

97.5<br />

7.0<br />

TYP.<br />

109.9<br />

29.2<br />

12<br />

12<br />

12<br />

12<br />

63.0<br />

24.5<br />

1 3<br />

10<br />

10<br />

10<br />

10<br />

21.5<br />

25.0 20.5<br />

B<br />

A<br />

Dim.<br />

26 mm<br />

38 mm<br />

“A”<br />

26.0<br />

38.0<br />

“B”<br />

75.1<br />

87.1<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

3/2 NO-NC 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

non plug-in<br />

cylinder ports<br />

in base<br />

26 mm<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

37A-C10-HXXX-XXX<br />

1 3<br />

37A-D10-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

A 18”<br />

1 Non-locking<br />

MA<br />

Plug-in wire assy<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

MC<br />

Plug-in wire assy<br />

with light<br />

DA 24VDC (5.2 W)<br />

x<br />

Other Options<br />

BA<br />

Flying leads<br />

AA<br />

120VAC (must use with<br />

BC<br />

Flying leads with light<br />

rectified connector)<br />

HA<br />

Plug-in connector with<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

EBM37A-00xxx-xx<br />

xx<br />

rectifier <strong>and</strong> light<br />

Other Options<br />

Port size<br />

Side cylinder ports (18 mm)<br />

Bottom cylinder ports (18 mm)<br />

1/8” NPTF<br />

1/4” NPTF<br />

6 mm tube receptacle<br />

EBM37A-00AAA-XX<br />

EBM37A-00AAB-XX<br />

EBM37A-00AAG-XX<br />

EBM37A-00BAA-XX<br />

EBM37A-00BAB-XX<br />

EBM37A-00BAG-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Dim.<br />

“B”<br />

1/4”<br />

16.5<br />

M6 Carstick<br />

18.5<br />

Number of 1 2 3 4 5 6 7 8 9 10<br />

stations<br />

“A” 50.0 68.0 86.0 104.0 122.0 140.0 158.0 176.0 194.0 212.0<br />

Dimensions are based on 18 mm centerline spacing<br />

75.10<br />

26.00<br />

49.00<br />

TYP.<br />

21.50<br />

TYP.<br />

3<br />

1<br />

1/4" - 18 N.P.T.F.<br />

2 HOLES<br />

BOTH ENDS<br />

1/4" - 19 B.S.P.TR<br />

2 HOLES<br />

BOTH ENDS<br />

1/4" - 19 B.P.S.PL<br />

2 HOLES<br />

BOTH ENDS<br />

35.50<br />

"B"<br />

2<br />

28.00<br />

7.00<br />

6.25 DIA.<br />

(2) MTG HOLES<br />

18.00<br />

TYP.<br />

18.00<br />

TYP.<br />

10<br />

2<br />

10<br />

"A"<br />

10<br />

10<br />

2<br />

2<br />

12<br />

12<br />

12<br />

12<br />

25.00 22.00<br />

TYP.<br />

BOTH<br />

ENDS<br />

DIM FOR 1/4" &<br />

M6 CARSTICK.<br />

7.00<br />

35.20<br />

1/4" - 18 N.P.T.F.<br />

TYP. PER STATION<br />

1/8" - 27 N.P.T.F.<br />

TYP. PER STATION<br />

1/4" - 19 B.S.P.TR<br />

TYP. PER STATION<br />

1/4" - 19 B.P.S.PL<br />

TYP. PER STATION<br />

1/8" - 28 B.S.P.TR.<br />

TYP. PER STATION<br />

1/8" - 28 B.S.P.PL.<br />

TYP. PER STATION<br />

13.00<br />

TYP.<br />

9.50<br />

TYP.<br />

3<br />

1<br />

* M6 Carstick available only on side port<br />

109.90<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

3/2 NO-NC 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

non plug-in<br />

cylinder ports<br />

in base with<br />

Pr. Reg.<br />

38 mm<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

37A-C1O-HXXX-XXX<br />

1 3<br />

37A-D1O-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

Voltage<br />

Wire length<br />

Manual operator<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

A 18”<br />

1 Non-locking<br />

MA<br />

Plug-in wire assy<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

MC<br />

Plug-in wire assy<br />

with light<br />

DA 24VDC (5.2 W)<br />

AA 120VAC (must use with<br />

x<br />

Other Options<br />

BA<br />

BC<br />

Flying leads<br />

Flying leads with light<br />

rectified connector)<br />

HA<br />

Plug-in connector with<br />

xx<br />

Other Options<br />

xx<br />

rectifier <strong>and</strong> light<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />

EBM37A-00xxx-xx<br />

Port size<br />

Side cylinder ports (18 mm)<br />

Bottom cylinder ports (18 mm)<br />

1/8” NPTF<br />

1/4” NPTF<br />

6 mm tube receptacle<br />

EBM37A-00FAA-XX<br />

EBM37A-00FAB-XX<br />

EBM37A-00FAG-XX<br />

EBM37A-00GAA-XX<br />

EBM37A-00GAB-XX<br />

EBM37A-00GAG-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

** Pressure Regulators :<br />

PR37A-GOAx<br />

X=A (0 to 120 PSI)<br />

X=B (0 to 80 PSI)<br />

X=C (0 to 30 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />

• Regulator blanking plate : R-47003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of 2 3 4 5 6 7 8 9 10 11<br />

stations<br />

“A” 63.7 81.7 99.7 117.7 135.7 153.7 171.7 189.7 207.7 225.7<br />

Dimensions are based on 18 mm centerline spacing<br />

87.6<br />

38.0<br />

1 3<br />

3/8" - 18 N.P.T.F.<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.S.P.TR<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.P.S.PL<br />

2 HOLES<br />

BOTH ENDS<br />

33.8<br />

10.0<br />

2<br />

18.0<br />

TYP.<br />

18.0<br />

TYP.<br />

2<br />

10<br />

"A"<br />

10<br />

12<br />

10<br />

12<br />

12<br />

GAGE<br />

6.25 DIA.<br />

2 MTG.<br />

HOLES<br />

2<br />

1/4" - 18 N.P.T.F.<br />

TYP. PER STATION<br />

1/8" - 27 N.P.T.F.<br />

TYP. PER STATION<br />

25.0 25.0<br />

TYP TYP BOTH<br />

BOTH ENDS<br />

ENDS<br />

2<br />

DIM. FOR 1/4" &<br />

M6 CARSTICK<br />

7.0<br />

TYP<br />

10<br />

33.8<br />

TYP<br />

12<br />

"E"<br />

1/4" - 19 B.S.P.TR<br />

TYP. PER STATION<br />

1/8" - 28 B.S.P.TR.<br />

TYP. PER STATION<br />

1/4" - 19 B.P.S.PL<br />

TYP. PER STATION<br />

1/8" - 28 B.S.P.PL.<br />

TYP. PER STATION<br />

3<br />

1<br />

Dim.<br />

“E”<br />

Regulator with locking<br />

adjusting screw<br />

135.8<br />

Regulator with<br />

adjusting screw<br />

131.8<br />

Regulator with<br />

adjusting knob<br />

139.6<br />

* M6 Carstick available only on side port<br />

Note: Bottom & side cylinder ports not available on the same station<br />

20.0<br />

TYP.<br />

21.5<br />

TYP.<br />

46.0<br />

TYP.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

3/2 NO-NC 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

non plug-in<br />

add-on style<br />

cylinder ports<br />

in base<br />

38 mm<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

37A-C1O-HXXX-XXX<br />

1 3<br />

37A-D1O-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

Voltage<br />

Wire length<br />

Manual operator<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

A 18”<br />

1 Non-locking<br />

MA<br />

Plug-in wire assy<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

MC<br />

Plug-in wire assy<br />

with light<br />

DA 24VDC (5.2 W)<br />

x<br />

Other Options<br />

BA<br />

Flying leads<br />

AA<br />

120VAC (must use with<br />

BC<br />

Flying leads with light<br />

rectified connector)<br />

HA<br />

Plug-in connector with<br />

xx<br />

Other Options<br />

xx<br />

rectifier <strong>and</strong> light<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

EBM37A-00xxx-xx<br />

Side cylinder ports (18 mm)<br />

Bottom cylinder ports (18 mm)<br />

1/8” NPTF<br />

1/4” NPTF<br />

6 mm tube receptacle<br />

EBM37A-00DBA-XX<br />

EBM37A-00DBB-XX<br />

EBM37A-00DBG-XX<br />

EBM37A-00EBA-XX<br />

EBM37A-00EBB-XX<br />

EBM37A-00EBG-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

add-a-unit stations may be added to above bars. Clic here for model numbers.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001. • End plate Kit : M-37005-0<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

12<br />

12<br />

12<br />

12<br />

1<br />

2<br />

2 2<br />

114.4<br />

63.0<br />

24.5<br />

10<br />

10<br />

10<br />

10<br />

21.5<br />

3<br />

33.8<br />

99.6<br />

7.0<br />

TYP.<br />

21.7 18.0 25.0<br />

87.6<br />

2 2 2<br />

38.0<br />

10.0<br />

25.0 18.0 21.7 26.8<br />

Note: Bottom & side cylinder ports not available on the same station<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

3/2 NO-NC 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

non plug-in<br />

add-a-unit<br />

stations<br />

38 mm<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

37A-C1O-HXXX-XXX<br />

1 3<br />

37A-D1O-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

Voltage<br />

Wire length<br />

Manual operator<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

A 18”<br />

1 Non-locking<br />

MA<br />

Plug-in wire assy<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

MC<br />

Plug-in wire assy<br />

with light<br />

DA 24VDC (5.2 W)<br />

x<br />

Other Options<br />

BA<br />

Flying leads<br />

AA<br />

120VAC (must use with<br />

BC<br />

Flying leads with light<br />

rectified connector)<br />

HA<br />

Plug-in connector with<br />

xx<br />

Other Options<br />

xx<br />

rectifier <strong>and</strong> light<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

EBM37A-00xxx-xx<br />

Side cylinder ports (18 mm)<br />

Bottom cylinder ports (18 mm)<br />

1/8” NPTF<br />

1/4” NPTF<br />

6 mm tube receptacle<br />

EBM37A-00DCA-XX<br />

EBM37A-00DCB-XX<br />

EBM37A-00DCG-XX<br />

EBM37A-00ECA-XX<br />

EBM37A-00ECB-XX<br />

EBM37A-00ECG-XX<br />

Number of stations (01, 02, 03 or 04)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />

• O-ring port seal (x2) : 17015-01. • Tie rod (x2) : 79007-01 (one station length)<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

12<br />

12<br />

12<br />

12<br />

1<br />

2<br />

2 2<br />

114.4<br />

63.0<br />

24.5<br />

10<br />

10<br />

10<br />

10<br />

21.5<br />

3<br />

33.8<br />

99.6<br />

7.0<br />

TYP.<br />

21.7 18.0 25.0<br />

87.6<br />

2 2 2<br />

38.0<br />

10.0<br />

25.0 18.0 21.7 26.8<br />

Note: Bottom & side cylinder ports not available on the same station<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

3/2 NO-NC 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

plug-in<br />

32.5 mm<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

37A-C1O-HXXP-XXX<br />

1 3<br />

37A-D1O-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

FA<br />

Plug-in<br />

DB 24VDC (2.4 W)<br />

FC<br />

Plug-in with light<br />

DA 24VDC (5.2 W)<br />

FE<br />

Plug-in with suppression diode<br />

AA<br />

120VAC (Mod. No. required see below)<br />

FG<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

xx<br />

with LED light<br />

Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR**<br />

ECD37A-xxxxx-xxxx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

18<br />

ECD37A-00AAA-A0XX<br />

ECD37A-00BAA-A0XX<br />

1/4” NPTF<br />

18<br />

ECD37A-00AAB-A0XX<br />

ECD37A-00BAB-A0XX<br />

6 mm tube receptacle<br />

18<br />

ECD37A-00AAG-A0XX<br />

ECD37A-00BAG-A0XX<br />

1/8” NPTF<br />

30<br />

ECD37A-01AAA-C0XX<br />

ECD37A-01BAA-C0XX<br />

1/4” NPTF<br />

30<br />

ECD37A-01AAB-C0XX<br />

ECD37A-01BAB-C0XX<br />

6 mm tube receptacle<br />

30<br />

ECD37A-01AAG-C0XX<br />

ECD37A-01BAG-C0XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector (9, 15 or 25).<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />

• Base wire plug-in protector : 16520.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

109.1<br />

COND.<br />

1<br />

3<br />

19.5 20.7<br />

TYP. TYP.<br />

3/8" N.P.T.F.<br />

2 HOLES<br />

BOTH ENDS<br />

28.15<br />

31.7<br />

TYP.<br />

6.0<br />

TYP.<br />

9.5<br />

22.85<br />

22.85<br />

12<br />

10<br />

12<br />

10<br />

18.0<br />

TYP.<br />

18.0<br />

TYP.<br />

A<br />

12<br />

10<br />

12<br />

10<br />

2<br />

2<br />

2<br />

2<br />

6.25 DIA.<br />

2 MTG.<br />

HOLES<br />

1/2"-14 N.P.S.M. CONDUIT<br />

68.0<br />

29.2<br />

14.6<br />

TYP.<br />

COND.<br />

1 3<br />

18.0<br />

TYP.<br />

42.1<br />

TYP.<br />

75.6<br />

TYP.<br />

32.5<br />

Number of 1 2 3 4 5 6 7 8 9 10<br />

stations<br />

“A” 45.7 63.7 81.7 99.7 117.7 135.7 153.7 171.7 189.7 207.7<br />

Dimensions are based on 18 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

3/2 NO-NC 1/8” - 1/4” 0.5C v<br />

plug-in<br />

with Pr. Reg.<br />

44 mm<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

37A-C1O-HXXP-XXX<br />

1 3<br />

37A-D1O-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

FA<br />

Plug-in<br />

DB 24VDC (2.4 W)<br />

FC<br />

Plug-in with light<br />

DA 24VDC (5.2 W)<br />

FE<br />

Plug-in with suppression diode<br />

AA<br />

120VAC (Mod. No. required see below)<br />

FG<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

xx<br />

with LED light<br />

Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />

ECD37A-xxxxx-xxxx<br />

Port size<br />

Spacing mm<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

1/4” NPTF<br />

1/8” NPTF<br />

1/4” NPTF<br />

18<br />

18<br />

30<br />

30<br />

ECD37A-00CDA-A0XX<br />

ECD37A-00CDB-A0XX<br />

ECD37A-01CDA-C0XX<br />

ECD37A-01CDB-C0XX<br />

Number of stations (03=3 stations)<br />

** Other options available, consult factory.<br />

Note :<br />

clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector (9, 15 or 25).<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

** Pressure Regulators :<br />

PR37A-GOAx<br />

X=A (0 to 120 PSI)<br />

X=B (0 to 80 PSI)<br />

X=C (0 to 30 PSI)<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />

• Base wire plug-in protector : 16520. • Regulator blanking plate : R-47003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

B<br />

D<br />

SHOWN W\ SANDWICH<br />

REGULATOR<br />

COND.<br />

116.1<br />

1"- 11 1/2 N.P.S.M.<br />

CONDUIT<br />

1<br />

3<br />

3/8" N.P.T.F.<br />

3 HOLES<br />

BOTH ENDS<br />

SHOWN W\ STANDARD<br />

REGULATOR<br />

40.7<br />

20.35<br />

COND. 1<br />

3<br />

44.0<br />

19.2 23.2<br />

TYP. TYP.<br />

33.0<br />

TYP. 6.0<br />

TYP.<br />

9.5<br />

18.5<br />

TYP.<br />

48.6<br />

TYP.<br />

87.1<br />

TYP.<br />

33.55<br />

A<br />

22.85<br />

12<br />

12<br />

10<br />

10<br />

2<br />

18.0<br />

TYP.<br />

18.0<br />

TYP.<br />

2<br />

C<br />

12<br />

10<br />

12<br />

10<br />

Dim.<br />

“A”<br />

Dim.<br />

“B”<br />

“D”<br />

1/4”<br />

25.85<br />

1/8”<br />

25.85<br />

Regulator with locking<br />

adjusting screw<br />

188.8<br />

182.5<br />

6 mm Legris<br />

22.85<br />

Regulator with<br />

adjusting screw<br />

184.7<br />

178.4<br />

6.25 DIA.<br />

2 MTG.<br />

HOLES<br />

Number of 1 2 3 4 5 6 7 8 9 10<br />

stations<br />

Regulator with<br />

“C” 45.7 63.7 81.7 99.7 117.7 135.7 153.7 171.7 189.7 207.7<br />

adjusting knob<br />

191.7<br />

Dimensions are based on 18 mm centerline spacing<br />

185.4<br />

Note: Bottom & side cylinder ports not available on the same station<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

3/2 NO-NC 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

add-on style<br />

plug-in<br />

44 mm<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

37A-C1O-HXXP-XXX<br />

1 3<br />

37A-D1O-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

FA<br />

Plug-in<br />

DB 24VDC (2.4 W)<br />

FC<br />

Plug-in with light<br />

DA 24VDC (5.2 W)<br />

FE<br />

Plug-in with suppression diode<br />

AA<br />

120VAC (Mod. No. required see below)<br />

FG<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

xx<br />

with LED light<br />

Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR**<br />

ECD37A-xxxxx-xxxx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

18<br />

ECD37A-00AEA-A0XX<br />

ECD37A-00BEA-A0XX<br />

1/4” NPTF<br />

18<br />

ECD37A-00AEB-A0XX<br />

ECD37A-00BEB-A0XX<br />

6 mm tube receptacle<br />

18<br />

ECD37A-00AEG-A0XX<br />

ECD37A-00BEG-A0XX<br />

1/8” NPTF<br />

30<br />

ECD37A-01AEA-C0XX<br />

ECD37A-01BEA-C0XX<br />

1/4” NPTF<br />

30<br />

ECD37A-01AEB-C0XX<br />

ECD37A-01BEB-C0XX<br />

6 mm tube receptacle<br />

30<br />

ECD37A-01AEG-C0XX<br />

ECD37A-01BEG-C0XX<br />

Number of stations (03=3 stations)<br />

** Other options available, consult factory.<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

clic for multi-pin connector (9, 15 or 25).<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

add-a-unit stations may be added to above bars. Clic here for model numbers.<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001. • End plate kit : M-37003-01<br />

• Base wire plug-in protector : 16520. • Isolator disc between add-a-units : 28438.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

“C” w/regulator<br />

1<br />

-<br />

2<br />

53.6<br />

3<br />

71.6<br />

4<br />

89.6<br />

5<br />

6<br />

7<br />

107.6 125.6 143.6 161.6 179.6 197.6<br />

8<br />

9<br />

10<br />

117.3<br />

1"-11 1/2 N.P.S.M. CONDUIT<br />

“C” w/o regulator<br />

-<br />

51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />

“D” 21.7 39.7 57.7 75.7 - - - - -<br />

Dimensions are based on 18 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

-<br />

3<br />

1<br />

COND.<br />

79.2<br />

3/8" N.PT.F.<br />

TYP.(2) BOTH ENDS<br />

2<br />

10.85<br />

TYP.<br />

10.85<br />

TYP.<br />

2<br />

10<br />

12<br />

16.0<br />

D<br />

10<br />

2<br />

12<br />

2<br />

B<br />

A<br />

2<br />

10<br />

12<br />

C<br />

33.55<br />

TYP.<br />

9.5<br />

TYP.<br />

6.0<br />

TYP.<br />

33.0<br />

TYP.<br />

6.25 DIA. HOLE<br />

TYP.(2)<br />

44.0<br />

23.2<br />

TYP.<br />

19.2<br />

TYP.<br />

3<br />

1<br />

COND.<br />

40.7<br />

20.35<br />

TYP.<br />

18.5<br />

TYP.<br />

48.6<br />

TYP.<br />

Dim.<br />

“A”<br />

1/8”<br />

22.65<br />

1/4”<br />

24.20<br />

6 mm Legris<br />

22.85<br />

1/8” w/regulator<br />

-<br />

1/4” w/regulator<br />

-<br />

87.1<br />

TYP.<br />

“B”<br />

22.85<br />

22.85<br />

25.85<br />

21.20<br />

22.60<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

3/2 NO-NC 1/8” - 1/4” 0.5C v<br />

add-on style<br />

plug in<br />

with Pr. Reg.<br />

44 mm<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

37A-C1O-HXXP-XXX<br />

1 3<br />

37A-D1O-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

FA<br />

Plug-in<br />

DB 24VDC (2.4 W)<br />

FC<br />

Plug-in with light<br />

DA 24VDC (5.2 W)<br />

FE<br />

Plug-in with suppression diode<br />

AA<br />

120VAC (Mod. No. required see below)<br />

FG<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

xx<br />

with LED light<br />

Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />

ECD37A-xxxxx-xxxx<br />

Port size<br />

Spacing mm<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

1/4” NPTF<br />

1/8” NPTF<br />

1/4” NPTF<br />

18<br />

18<br />

30<br />

30<br />

ECD37A-00CEA-A0XX<br />

ECD37A-00CEB-A0XX<br />

ECD37A-01CEA-C0XX<br />

ECD37A-01CEB-C0XX<br />

Number of stations (03=3 stations)<br />

** Pressure Regulators :<br />

** Other options available, consult factory.<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number. PR37A-GOAx<br />

clic for multi-pin connector (9, 15 or 25).<br />

X=A (0 to 120 PSI)<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

X=B (0 to 80 PSI)<br />

add-a-unit stations may be added to above bars. Clic here for model numbers. X=C (0 to 30 PSI)<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001. • End plate kit : M-37003-01<br />

• Base wire plug-in protector : 16520. • Isolator disc between add-a-units : 28438.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

“C” w/regulator<br />

1<br />

-<br />

2<br />

53.6<br />

3<br />

71.6<br />

4<br />

89.6<br />

5<br />

6<br />

7<br />

107.6 125.6 143.6 161.6 179.6 197.6<br />

8<br />

9<br />

10<br />

E<br />

SHOWN W/STANDARD<br />

REGULATOR<br />

117.3<br />

1"-11 1/2 N.P.S.M. CONDUIT<br />

“C” w/o regulator<br />

“D”<br />

-<br />

21.7<br />

51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />

39.7 57.7 75.7 - - - - - -<br />

3<br />

1<br />

COND.<br />

Dimensions are based on 18 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

79.2<br />

3/8" N.PT.F.<br />

TYP.(2) BOTH ENDS<br />

2<br />

10.85<br />

TYP.<br />

10.85<br />

TYP.<br />

2<br />

10<br />

12<br />

16.0<br />

D<br />

10<br />

2<br />

12<br />

2<br />

B<br />

A<br />

2<br />

10<br />

12<br />

C<br />

33.55<br />

TYP.<br />

9.5<br />

TYP.<br />

6.0<br />

TYP.<br />

33.0<br />

TYP.<br />

6.25 DIA. HOLE<br />

TYP.(2)<br />

F<br />

SHOWN W/SANDWICH<br />

REGULATOR<br />

Dim.<br />

“A”<br />

“B”<br />

1/8”<br />

22.65<br />

22.85<br />

1/4”<br />

24.20<br />

22.85<br />

6 mm Legris<br />

22.85<br />

25.85<br />

1/8” w/regulator<br />

-<br />

21.20<br />

1/4” w/regulator<br />

-<br />

22.60<br />

103.0<br />

44.0<br />

23.2<br />

TYP.<br />

19.2<br />

TYP.<br />

3<br />

1<br />

COND.<br />

40.7<br />

20.35<br />

TYP.<br />

Dim.<br />

“E”<br />

“F”<br />

Regulator with locking<br />

adjusting screw<br />

188.8<br />

182.5<br />

Regulator with<br />

adjusting screw<br />

184.7<br />

178.4<br />

Regulator with<br />

adjusting knob<br />

191.7<br />

185.4<br />

18.5<br />

TYP.<br />

48.6<br />

TYP.<br />

87.1<br />

TYP.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

3/2 NO-NC 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

plug-in<br />

add-a-unit<br />

stations<br />

44 mm<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

37A-C1O-HXXP-XXX<br />

1 3<br />

37A-D1O-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

FA<br />

Plug-in<br />

DB 24VDC (2.4 W)<br />

FC<br />

Plug-in with light<br />

DA 24VDC (5.2 W)<br />

FE<br />

Plug-in with suppression diode<br />

AA<br />

120VAC (Mod. No. required see below)<br />

FG<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

xx<br />

with LED light<br />

Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR**<br />

ECD37A-xxxxx-xxxx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

18<br />

ECD37A-00AFA-A0XX<br />

ECD37A-00BFA-A0XX<br />

1/4” NPTF<br />

18<br />

ECD37A-00AFB-A0XX<br />

ECD37A-00BFB-A0XX<br />

6 mm tube receptacle<br />

18<br />

ECD37A-00AFG-A0XX<br />

ECD37A-00BFG-A0XX<br />

1/8” NPTF<br />

30<br />

ECD37A-01AFA-C0XX<br />

ECD37A-01BFA-C0XX<br />

1/4” NPTF<br />

30<br />

ECD37A-01AFB-C0XX<br />

ECD37A-01BFB-C0XX<br />

6 mm tube receptacle<br />

30<br />

ECD37A-01AFG-C0XX<br />

ECD37A-01BFG-C0XX<br />

Number of stations (03=3 stations) - maximum length is 4 stations.<br />

** Other options available, consult factory.<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

when add-a-unit stations are added to bars with a multi-pin connector, mod SD03 should<br />

be included with add-a-unit model number.<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />

• O-ring port seal (x2) : 17015-01 • Tie rod (x2) : 79007-01 (one station length).<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

“C” w/regulator<br />

1<br />

-<br />

2<br />

53.6<br />

3<br />

71.6<br />

4<br />

89.6<br />

5 6 7 8 9 10<br />

107.6 125.6 143.6 161.6 179.6 197.6<br />

117.3<br />

1"-11 1/2 N.P.S.M. CONDUIT<br />

“C” w/o regulator<br />

“D”<br />

-<br />

21.7<br />

51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />

39.7 57.7 75.7 - - - - - -<br />

3<br />

1<br />

COND.<br />

Dimensions are based on 18 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

79.2<br />

3/8" N.PT.F.<br />

TYP.(2) BOTH ENDS<br />

2<br />

10.85<br />

TYP.<br />

10.85<br />

TYP.<br />

2<br />

10<br />

12<br />

16.0<br />

D<br />

10<br />

2<br />

12<br />

2<br />

B<br />

A<br />

2<br />

10<br />

12<br />

C<br />

33.55<br />

TYP.<br />

9.5<br />

TYP.<br />

6.0<br />

TYP.<br />

33.0<br />

TYP.<br />

6.25 DIA. HOLE<br />

TYP.(2)<br />

44.0<br />

23.2<br />

TYP.<br />

19.2<br />

TYP.<br />

3<br />

1<br />

COND.<br />

40.7<br />

20.35<br />

TYP.<br />

18.5<br />

TYP.<br />

48.6<br />

TYP.<br />

Dim.<br />

“A”<br />

1/8”<br />

22.65<br />

1/4”<br />

24.20<br />

6 mm Legris<br />

22.85<br />

1/8” w/regulator<br />

-<br />

1/4” w/regulator<br />

-<br />

87.1<br />

TYP.<br />

“B”<br />

22.85<br />

22.85<br />

25.85<br />

21.20<br />

22.60<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 37<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

3/2 NO-NC 1/8” - 1/4” 0.5C v<br />

add-a-unit<br />

stations<br />

plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

44 mm<br />

Reset<br />

HOW TO ORDER<br />

37A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Universal valve<br />

2<br />

NC only valve<br />

2<br />

Valve less base<br />

1 3<br />

37A-C1O-HXXP-XXX<br />

1 3<br />

37A-D1O-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

FA<br />

Plug-in<br />

DB 24VDC (2.4 W)<br />

FC<br />

Plug-in with light<br />

DA 24VDC (5.2 W)<br />

FE<br />

Plug-in with suppression diode<br />

AA<br />

120VAC (Mod. No. required see below)<br />

FG<br />

Plug-in with suppression diode<br />

xx<br />

Other Options<br />

xx<br />

with LED light<br />

Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />

ECD37A-xxxxx-xxxx<br />

Port size<br />

Spacing mm<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

1/4” NPTF<br />

1/8” NPTF<br />

1/4” NPTF<br />

18<br />

18<br />

30<br />

30<br />

ECD37A-00CFA-A0XX<br />

ECD37A-00CFB-A0XX<br />

ECD37A-01CFA-C0XX<br />

ECD37A-01CFB-C0XX<br />

Number of stations (03=3 stations) - maximum length is 4 stations.<br />

** Other options available, consult factory.<br />

Note : clic for valves mounted on base at the factory, add - 9 to the model number.<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

when add-a-unit stations are added to bars with a multi-pin connector, mod<br />

SD03 should be included with add-a-unit model number.<br />

** Pressure Regulators :<br />

PR37A-GOAx<br />

X=A (0 to 120 PSI)<br />

X=B (0 to 80 PSI)<br />

X=C (0 to 30 PSI)<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 37<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.25C v , 1.8 W : 0.15C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 17.0 ms<br />

De-energize : 6.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16630. • Mounting screw (x2) : 35043. • Blanking plate : M-37001.<br />

• O-ring port seal (x2) : 17015-01 • Tie rod (x2) : 79007-01 (one station length). • Regulator blanking plate : R-47003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

“C” w/regulator<br />

1<br />

-<br />

2<br />

53.6<br />

3<br />

71.6<br />

4<br />

89.6<br />

5<br />

6<br />

7<br />

107.6 125.6 143.6 161.6 179.6 197.6<br />

8<br />

9<br />

10<br />

E<br />

SHOWN W/STANDARD<br />

REGULATOR<br />

117.3<br />

1"-11 1/2 N.P.S.M. CONDUIT<br />

“C” w/o regulator<br />

“D”<br />

-<br />

21.7<br />

51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />

39.7 57.7 75.7 - - - - - -<br />

3<br />

1<br />

COND.<br />

Dimensions are based on 18 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

79.2<br />

3/8" N.PT.F.<br />

TYP.(2) BOTH ENDS<br />

2<br />

10.85<br />

TYP.<br />

10.85<br />

TYP.<br />

2<br />

10<br />

12<br />

16.0<br />

D<br />

10<br />

2<br />

12<br />

2<br />

B<br />

A<br />

2<br />

10<br />

12<br />

C<br />

33.55<br />

TYP.<br />

9.5<br />

TYP.<br />

6.0<br />

TYP.<br />

33.0<br />

TYP.<br />

6.25 DIA. HOLE<br />

TYP.(2)<br />

F<br />

SHOWN W/SANDWICH<br />

REGULATOR<br />

Dim.<br />

“A”<br />

“B”<br />

1/8”<br />

22.65<br />

22.85<br />

1/4”<br />

24.20<br />

22.85<br />

6 mm Legris<br />

22.85<br />

25.85<br />

1/8” w/regulator<br />

-<br />

21.20<br />

1/4” w/regulator<br />

-<br />

22.60<br />

103.0<br />

44.0<br />

23.2<br />

TYP.<br />

19.2<br />

TYP.<br />

3<br />

1<br />

COND.<br />

40.7<br />

20.35<br />

TYP.<br />

Dim.<br />

“E”<br />

“F”<br />

Regulator with locking<br />

adjusting screw<br />

188.8<br />

182.5<br />

Regulator with<br />

adjusting screw<br />

184.7<br />

178.4<br />

Regulator with<br />

adjusting knob<br />

191.7<br />

185.4<br />

18.5<br />

TYP.<br />

48.6<br />

TYP.<br />

87.1<br />

TYP.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Section 2 Options<br />

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Codification table for voltages / Wire length / Manual operators / Electrical connections<br />

VALVE CODE ➤<br />

- H XX X - X XX<br />

1 2 3 4<br />

OPTIONS AVAILABLE FOR<br />

- Solenoid valves 37 & 47 Series<br />

Consult “Precautions”before use, installation or service of MAC Valves.


OPTIONS<br />

Back<br />

1. VOLTAGE<br />

- H XX X - X XX VOLTAGE<br />

DC Options<br />

DA 24 VDC (5.2 W)<br />

DB 24 VDC (2.4 W)<br />

DC 24 VDC (1.8 W)<br />

DD 24 VDC (1.0 W)<br />

DF 12 VDC (5.2 W)<br />

DG 12 VDC (2.4 W)<br />

DH 12 VDC (1.8 W)<br />

DJ 12 VDC (1.0 W)<br />

DL 120 VDC (6.3 W)<br />

AC Options (50/60hz)<br />

AA 120 VAC (6.7 W)<br />

AB 220 VAC (5.6 W)<br />

AC 240 VAC (5.8 W)<br />

AD 24 VAC (7.8 W)<br />

Note : AC Voltages only available with “H” & “F” type connectors. MOD FWR2 must be used with the “F” type connectors.<br />

2. WIRE LENGTH<br />

- H XX X - X XX WIRE LENGTH<br />

O<br />

No lead wire<br />

A 18”<br />

B 24”<br />

C 36”<br />

D 48”<br />

E 72”<br />

F 96”<br />

G 120”<br />

H 144”<br />

P<br />

Plug-in (used only with “F”type connector Opts.)<br />

Use “O” with MJ & MM Opts.<br />

3. MANUAL OPERATOR<br />

- H XX X - X XX MANUAL OPERATOR<br />

0 No operator<br />

1 Non-locking recessed<br />

2 Locking recessed<br />

3 Non-locking extended<br />

4 Locking extended<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Back<br />

4. ELECTRICAL CONNECTION<br />

- H XX X - X XX ELECTRICAL CONNECTION<br />

BA Flying leads<br />

BB Flying leads with ground wire<br />

BC Flying leads with led light<br />

BD Flying leads with led light & ground wire<br />

BE Flying leads with suppression diode<br />

BF Flying leads with suppression diode & ground wire<br />

BG Flying leads with suppression diode plus led light<br />

BH Flying leads with suppression diode plus led light & ground wire<br />

*BN Flying leads with suppression diode plus blocking diode<br />

*BP Flying leads with suppression diode plus blocking diode & ground wire<br />

*BR Flying leads with suppression diode plus blocking diode & led light<br />

*BS Flying leads with suppression diode plus blocking diode & led light & ground wire<br />

FA<br />

FB<br />

FC<br />

FD<br />

FE<br />

FF<br />

FG<br />

FH<br />

Plug-in<br />

Plug-in with ground wire<br />

Plug-in with led light<br />

Plug-in with led light & ground wire<br />

Plug-in with suppression diode<br />

Plug-in with suppression diode & ground wire<br />

Plug-in with suppression diode plus led light<br />

Plug-in with suppression diode plus led light & ground wire<br />

Note : FA ---- FH options for use with ECD type circuit bars<br />

HA<br />

HB<br />

HC<br />

HD<br />

HL<br />

HN<br />

Circuit board plug-in with full wave rectifier & led light<br />

Circuit board with full wave rectifier & led with ground wire<br />

Same as “HA” without lead wires<br />

Same as “HB” without lead wires<br />

Circuit board plug-in with suppression diode plus blocking diode & led light<br />

Same as “HL” without lead wires<br />

MA Plug-in wire assembly<br />

MB Plug-in wire assembly with ground wire<br />

MC Plug-in wire assembly with led light<br />

MD Plug-in wire assembly led light & ground wire<br />

ME Plug-in wire assembly with suppression diode<br />

MF Plug-in wire assembly with suppression diode & ground wire<br />

*MG Plug-in wire assembly suppression diode plus led light<br />

*MH Plug-in wire assembly suppression diode plus led light & ground wire<br />

*MN Plug-in wire assembly with suppression diode plus blocking diode<br />

*MP Plug-in wire assembly with suppression diode plus blocking diode & ground wire<br />

MR Plug-in wire assembly with suppression diode plus blocking diode & led light<br />

MS Plug-in wire assembly with suppression diode plus blocking diode & led light & ground wire<br />

MJ Plug-in housing w/o wire assembly (“MA” option without wire assembly)<br />

MM Plug-in housing w/o wire assembly (“MB” option without wire assembly)<br />

* Blocking diode is in lead wire.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

PIN #6<br />

PIN #9<br />

MOD. SD09<br />

PIN #1<br />

PIN #5<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 9<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 7 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 2 common wires<br />

PIN #9<br />

PIN #15<br />

MOD. SD15<br />

PIN #1<br />

PIN #8<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 15<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 12 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 3 common wires<br />

PIN #14<br />

PIN #25<br />

MOD. SD25<br />

PIN #1<br />

PIN #13<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 25<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 20 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 5 common wires<br />

Note : Use desired MOD. number after circuit bar part number


O p t i o n s<br />

OPTIONS<br />

Connector termination details<br />

CONNECTOR<br />

SOL 1<br />

SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />

Single solenoid circuit bar<br />

SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />

CONNECTOR<br />

SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />

Double solenoid circuit bar<br />

SD09 SD15 SD25<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

8<br />

COMMON (+)<br />

13<br />

COMMON (+)<br />

21<br />

COMMON (+)<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

9<br />

COMMON (+)<br />

8<br />

SOL. 8<br />

8<br />

SOL. 8<br />

14<br />

COMMON (+)<br />

22<br />

COMMON (+)<br />

9<br />

SOL. 9<br />

9<br />

SOL. 9<br />

10 SOL. 10<br />

10 SOL. 10<br />

11<br />

SOL. 11<br />

11<br />

SOL. 11<br />

12 SOL. 12<br />

12 SOL. 12<br />

15<br />

COMMON (+)<br />

23<br />

COMMON (+)<br />

13<br />

SOL. 13<br />

14 SOL. 14<br />

15<br />

SOL. 15<br />

16 SOL. 16<br />

24<br />

COMMON (+)<br />

17<br />

18 SOL. 18<br />

19<br />

20 SOL. 20<br />

SOL. 17<br />

SOL. 19<br />

25<br />

COMMON (+)


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 52<br />

Circuit bar mounting<br />

cylinder ports<br />

in valve<br />

add-on style<br />

cylinder ports<br />

in valve<br />

cylinder ports<br />

in base<br />

add-on style<br />

cylinder ports<br />

in base<br />

add-a-unit<br />

stations for<br />

CBM052A bar<br />

add-a-unit<br />

stations for<br />

CBP052A bar<br />

Manual operator<br />

Solenoid<br />

4-way pilot with balanced poppet<br />

Bonded spool<br />

2<br />

Air return<br />

3<br />

1<br />

SERIES FEATURES<br />

• Patented MACSOLENOID ® for fastest possible response times<br />

<strong>and</strong> virtually burn-out proof AC solenoid operation.<br />

• Optional low watt DC solenoids.<br />

• Various manual operators.<br />

• Optional memory spring.<br />

• Normally closed or normally open valve function.<br />

• May be plugged for 2-way operation.<br />

• Internal or external pilot.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 52<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC 1/8” - 1/4” 1.2C v<br />

cylinder ports<br />

in valve<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

52A-xx-xxx-DM-Dxxx-xxx<br />

SOLENOID OPERATOR<br />

Port size<br />

Pilot air<br />

Single operator<br />

NO valve<br />

NC valve<br />

Double operator<br />

NO valve<br />

NC valve<br />

10<br />

2<br />

12<br />

10<br />

2<br />

12<br />

10<br />

2<br />

12<br />

10<br />

2<br />

12<br />

1/8” NPTF<br />

Internal<br />

3 1<br />

52A-31-COA-DM-DXXX-XXX<br />

52A-31-AOA-DM-DXXX-XXX<br />

3 1<br />

52A-11-AOA-DM-DXXX-XXX<br />

3 1<br />

52A-41-AOA-DM-DXXX-XXX<br />

3 1<br />

52A-21-AOA-DM-DXXX-XXX<br />

1/4” NPTF<br />

52A-31-BOA-DM-DXXX-XXX<br />

52A-11-BOA-DM-DXXX-XXX<br />

52A-41-BOA-DM-DXXX-XXX<br />

52A-21-BOA-DM-DXXX-XXX<br />

1/8” NPTF<br />

External<br />

52A-31-AOC-DM-DXXX-XXX<br />

52A-11-AOC-DM-DXXX-XXX<br />

52A-41-AOC-DM-DXXX-XXX<br />

52A-21-AOC-DM-DXXX-XXX<br />

1/4” NPTF<br />

52A-31-BOC-DM-DXXX-XXX<br />

52A-11-BOC-DM-DXXX-XXX<br />

52A-41-BOC-DM-DXXX-XXX<br />

52A-21-BOC-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X - X XX *<br />

XX Voltage<br />

X Wire length<br />

X<br />

Manual operator<br />

XX<br />

Electrical connection<br />

JA 120/60, 110/50<br />

A<br />

18” (Flying leads)<br />

1 Non-locking<br />

KA<br />

Square connector<br />

JB 240/60, 220/50<br />

J<br />

Connector<br />

2 Locking<br />

KD<br />

Square connector<br />

with light<br />

JC 24/60, 24/50<br />

x<br />

Other Options<br />

x<br />

Other Options<br />

JB<br />

Rectangular connector<br />

DA 24VDC (5.4 W)<br />

JD<br />

Rectangular connector<br />

with light<br />

FB 24VDC (1.8 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

CBM052A-xxxxx-xx<br />

BA<br />

xx<br />

Flying leads<br />

Other Options<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard<br />

19,5 mm<br />

Spacing 26 mm<br />

(Rectangular connector)<br />

3/8” NPTF<br />

Internal<br />

CBM052A-00AAA-XX<br />

CBM052A-02AAA-XX<br />

External<br />

CBM052A-00CAA-XX<br />

CBM052A-02CAA-XX<br />

Number of stations (03=3 stations)<br />

* * Other options available. Consult factory.<br />

3<br />

O P T I O N S<br />

52A-31-AOA-DM-DXXX-XXX<br />

clic for memory spring (replace by 4).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 52<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum to 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

7.3 mm<br />

1.2C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04001. • Seal (x3) : 17015-01. • Mounting screw (x2) : 35043.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

6,5 DIA.<br />

2 HOLES<br />

32,0<br />

25,0<br />

3<br />

1<br />

2<br />

10<br />

12<br />

89,0<br />

19,5<br />

10<br />

2<br />

2<br />

2<br />

12<br />

102,3<br />

2<br />

10<br />

12<br />

2<br />

40,0<br />

26,5<br />

3<br />

1<br />

7,0<br />

38,2<br />

102,5<br />

1/8” OPTIONAL COMMON<br />

EXTERNAL PILOT.<br />

14,5<br />

51,5<br />

69,5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 52<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC 1/8” - 1/4” 1.2C v<br />

add-on style<br />

cylinder ports<br />

in valve<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

52A-xx-xxx-DM-Dxxx-xxx<br />

SOLENOID OPERATOR<br />

Port size<br />

Pilot air<br />

Single operator<br />

NO valve<br />

NC valve<br />

Double operator<br />

NO valve<br />

NC valve<br />

10<br />

2<br />

12<br />

10<br />

2<br />

12<br />

10<br />

2<br />

12<br />

10<br />

2<br />

12<br />

1/8” NPTF<br />

Internal<br />

3 1<br />

52A-31-COA-DM-DXXX-XXX<br />

52A-31-AOA-DM-DXXX-XXX<br />

3 1<br />

52A-11-AOA-DM-DXXX-XXX<br />

3 1<br />

52A-41-AOA-DM-DXXX-XXX<br />

3 1<br />

52A-21-AOA-DM-DXXX-XXX<br />

1/4” NPTF<br />

52A-31-BOA-DM-DXXX-XXX<br />

52A-11-BOA-DM-DXXX-XXX<br />

52A-41-BOA-DM-DXXX-XXX<br />

52A-21-BOA-DM-DXXX-XXX<br />

1/8” NPTF<br />

External<br />

52A-31-AOC-DM-DXXX-XXX<br />

52A-11-AOC-DM-DXXX-XXX<br />

52A-41-AOC-DM-DXXX-XXX<br />

52A-21-AOC-DM-DXXX-XXX<br />

1/4” NPTF<br />

52A-31-BOC-DM-DXXX-XXX<br />

52A-11-BOC-DM-DXXX-XXX<br />

52A-41-BOC-DM-DXXX-XXX<br />

52A-21-BOC-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X - X XX *<br />

XX Voltage<br />

X Wire length<br />

X<br />

Manual operator<br />

XX<br />

Electrical connection<br />

JA 120/60, 110/50<br />

A<br />

18” (Flying leads)<br />

1 Non-locking<br />

KA<br />

Square connector<br />

JB 240/60, 220/50<br />

J<br />

Connector<br />

2 Locking<br />

KD<br />

Square connector<br />

with light<br />

JC 24/60, 24/50<br />

x<br />

Other Options<br />

x<br />

Other Options<br />

JB<br />

Rectangular connector<br />

DA 24VDC (5.4 W)<br />

JD<br />

Rectangular connector<br />

with light<br />

FB 24VDC (1.8 W)<br />

BA<br />

Flying leads<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

CBM052A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard<br />

19,5 mm<br />

Spacing 26 mm<br />

(Rectangular connector)<br />

3/8” NPTF<br />

Internal<br />

CBM052A-00ABA-XX<br />

CBM052A-02ABA-XX<br />

External<br />

CBM052A-00CBA-XX<br />

CBM052A-02CBA-XX<br />

Number of stations (03=3 stations)<br />

* * Other options available. Consult factory.<br />

O P T I O N S<br />

Note : add-a-unit stations may be added to above bars. Clic here for model numbers.<br />

52A-31-AOA-DM-DXXX-XXX<br />

clic for memory spring (replace by 4).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 52<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum to 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

7.3 mm<br />

1.2C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04001. • Seal (x3) : 17015-01. • Mounting screw (x2) : 35043. • End plate kit (Internal) : M-52001-01.<br />

• End plate kit (External) : M-52002-01.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

CL CL CL CL<br />

40.0<br />

102.3<br />

XX<br />

CL CL CL CL<br />

1/8" OR 1/4"<br />

PORTS AVAILABLE<br />

ON THE BOTTOM OR SIDE<br />

23.2<br />

21.0<br />

10.0<br />

96.0<br />

35.0<br />

1 3<br />

12 12<br />

10<br />

10<br />

12<br />

10<br />

12<br />

10<br />

1<br />

3<br />

MODEL<br />

69.5<br />

52.5<br />

29.0<br />

14.5<br />

6.5 DIA.<br />

2 MTG.<br />

HOLES<br />

1 3<br />

38.2<br />

25.0<br />

YY<br />

21.0<br />

10.8<br />

16.0<br />

3/8" N.P.T.F.<br />

2 PLACES<br />

BOTH ENDS<br />

1/8" OPTIONAL<br />

COMMON EXTERNAL<br />

PILOT<br />

CL CL CL CL<br />

7.0<br />

TYP.<br />

YY<br />

19.5<br />

26<br />

XX<br />

113<br />

119.5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 52<br />

Function Port size Flow (Max) Individual mounting<br />

3/2 NO-NC 1/8” - 1/4” 1.2C v<br />

cylinder ports<br />

in base<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

52A-xx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Pilot air<br />

Single operator<br />

Double operator<br />

NO valve<br />

2<br />

10<br />

12<br />

NC valve<br />

2<br />

10<br />

12<br />

10<br />

NO valve<br />

2<br />

12<br />

10<br />

NC valve<br />

2<br />

12<br />

Internal<br />

3 1<br />

52A-33-OOA-DM-DXXX-XXX<br />

3 1<br />

52A-13-OOA-DM-DXXX-XXX<br />

3 1<br />

52A-43-OOA-DM-DXXX-XXX<br />

3 1<br />

52A-23-OOA-DM-DXXX-XXX<br />

External<br />

52A-33-OOC-DM-DXXX-XXX<br />

52A-13-OOC-DM-DXXX-XXX<br />

52A-43-OOC-DM-DXXX-XXX<br />

52A-23-OOC-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X - X XX *<br />

Voltage<br />

Wire length<br />

Manual operator<br />

XX X X XX<br />

JA 120/60, 110/50<br />

JB 240/60, 220/50<br />

JC 24/60, 24/50<br />

DA 24VDC (5.4 W)<br />

FB 24VDC (1.8 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

A 18” (Flying leads)<br />

1 Non-locking<br />

KA<br />

J Connector<br />

2 Locking<br />

KD<br />

x Other Options<br />

x Other Options<br />

JB<br />

JD<br />

BA<br />

xx<br />

CBP052A-xxxxx-xx<br />

Electrical connection<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

Port size (NPTF)<br />

Pilot air<br />

Spacing st<strong>and</strong>ard<br />

19,5 mm<br />

Spacing 26 mm<br />

(Rectangular connector)<br />

1/8” SIDE PORT<br />

Internal<br />

CBP052A-00AAA-XX<br />

CBP052A-02AAA-XX<br />

1/4” SIDE PORT<br />

CBP052A-00AAD-XX<br />

CBP052A-02AAD-XX<br />

1/8” SIDE PORT<br />

External<br />

CBP052A-00EAA-XX<br />

CBP052A-02EAA-XX<br />

1/4” SIDE PORT<br />

CBP052A-00EAD-XX<br />

CBP052A-02EAD-XX<br />

1/8” BOTTOM PORT<br />

Internal<br />

CBP052A-00BAA-XX<br />

CBP052A-02BAA-XX<br />

1/4” BOTTOM PORT<br />

CBP052A-00BAD-XX<br />

CBP052A-02BAD-XX<br />

1/8” BOTTOM PORT<br />

External<br />

CBP052A-00FAA-XX<br />

CBP052A-02FAA-XX<br />

1/4” BOTTOM PORT<br />

CBP052A-00FAD-XX<br />

CBP052A-02FAD-XX<br />

Number of stations (03=3 stations) ** Other options available. Consult factory.<br />

O P T I O N S<br />

52A-33-OOA-DM-DXXX-XXX<br />

clic for memory spring (replace by 6).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 52<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum to 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

7.3 mm<br />

1.2C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-52003. • Seal (x3) : 17013-01. • Mounting screw (x2) : 35043.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

25,0<br />

3<br />

1<br />

2<br />

10<br />

12<br />

90,5<br />

19,5<br />

2<br />

2<br />

10<br />

12<br />

2<br />

2<br />

10,5<br />

10<br />

2<br />

12<br />

16,0<br />

3<br />

1<br />

7,0<br />

36,0<br />

96,0<br />

32,0<br />

102,3<br />

23,2<br />

21,0<br />

10,0<br />

10,0<br />

14,5<br />

29,0<br />

51,5<br />

3/8"<br />

OPTIONAL 1/8" COMMON<br />

EXTERNAL PILOT<br />

25,0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 52<br />

Function Port size Flow (Max) Individual mounting<br />

3/2 NO-NC 1/8” - 1/4” 1.2C v<br />

add-on style<br />

cylinder ports<br />

in base<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

52A-xx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Pilot air<br />

Single operator<br />

Double operator<br />

NO valve<br />

2<br />

10<br />

12<br />

NC valve<br />

2<br />

10<br />

12<br />

10<br />

NO valve<br />

2<br />

12<br />

10<br />

NC valve<br />

2<br />

12<br />

Internal<br />

3 1<br />

52A-33-OOA-DM-DXXX-XXX<br />

3 1<br />

52A-13-OOA-DM-DXXX-XXX<br />

3 1<br />

52A-43-OOA-DM-DXXX-XXX<br />

3 1<br />

52A-23-OOA-DM-DXXX-XXX<br />

External<br />

52A-33-OOC-DM-DXXX-XXX<br />

52A-13-OOC-DM-DXXX-XXX<br />

52A-43-OOC-DM-DXXX-XXX<br />

52A-23-OOC-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X - X XX *<br />

Voltage<br />

Wire length<br />

Manual operator<br />

XX X X XX<br />

JA 120/60, 110/50<br />

JB 240/60, 220/50<br />

JC 24/60, 24/50<br />

DA 24VDC (5.4 W)<br />

FB 24VDC (1.8 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

A 18” (Flying leads)<br />

1 Non-locking<br />

KA<br />

J Connector<br />

2 Locking<br />

KD<br />

x Other Options<br />

x Other Options<br />

JB<br />

JD<br />

BA<br />

xx<br />

CBP052A-xxxxx-xx<br />

Electrical connection<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

Port size (NPTF)<br />

Pilot air<br />

Spacing st<strong>and</strong>ard<br />

19,5 mm<br />

Spacing 26 mm<br />

(Rectangular connector)<br />

1/8” SIDE PORT<br />

Internal<br />

CBP052A-00ABA-XX<br />

CBP052A-02ABA-XX<br />

1/4” SIDE PORT<br />

CBP052A-00ABD-XX<br />

CBP052A-02ABD-XX<br />

1/8” SIDE PORT<br />

External<br />

CBP052A-00EBA-XX<br />

CBP052A-02EBA-XX<br />

1/4” SIDE PORT<br />

CBP052A-00EBD-XX<br />

CBP052A-02EBD-XX<br />

1/8” BOTTOM PORT<br />

Internal<br />

CBP052A-00BBA-XX<br />

CBP052A-02BBA-XX<br />

1/4” BOTTOM PORT<br />

CBP052A-00BBD-XX<br />

CBP052A-02BBD-XX<br />

1/8” BOTTOM PORT<br />

External<br />

CBP052A-00FBA-XX<br />

CBP052A-02FBA-XX<br />

1/4” BOTTOM PORT<br />

CBP052A-00FBD-XX<br />

CBP052A-02FBD-XX<br />

Number of stations (03=3 stations) ** Other options available. Consult factory.<br />

O P T I O N S<br />

Note : add-a-unit stations may be added to above bars.<br />

Clic here for model numbers.<br />

52A-33-OOA-DM-DXXX-XXX<br />

clic for memory spring (replace by 6).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 52<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum to 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

7.3 mm<br />

1.2C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-52003. • Seal (x3) : 17013-01. • Mounting screw (x2) : 35043. • End plate kit (Internal) : M-52001-01.<br />

• End plate kit (External) : M-52002-01.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

10.0<br />

CL<br />

CL<br />

CL<br />

CL<br />

1/8" OR 1/4"<br />

PORTS AVAILABLE<br />

ON THE BOTTOM OR SIDE<br />

40.0<br />

2<br />

2<br />

2<br />

2<br />

102.3<br />

XX<br />

CL<br />

CL<br />

CL<br />

CL<br />

23.2<br />

21.0<br />

10.0<br />

96.0<br />

1<br />

12<br />

12<br />

12<br />

12<br />

1<br />

MODEL<br />

69.5<br />

6.5 DIA.<br />

2 MTG.<br />

HOLES<br />

1<br />

3<br />

10<br />

10<br />

10<br />

10<br />

3<br />

14.5<br />

29.0<br />

52.5<br />

3<br />

2<br />

2<br />

2<br />

2<br />

ZZ<br />

38.2<br />

25.0<br />

YY<br />

21.0<br />

10.8<br />

16.0<br />

3/8" N.P.T.F.<br />

2 PLACES<br />

BOTH ENDS<br />

1/8" OPTIONAL<br />

COMMON EXTERNAL<br />

PILOT<br />

YY<br />

CL<br />

CL<br />

XX<br />

CL<br />

CL<br />

PORT<br />

7.0<br />

TYP.<br />

ZZ<br />

19.5<br />

113<br />

1/8”<br />

36.0<br />

26<br />

119.5<br />

1/4”<br />

40.0<br />

Note: Bottom & side cylinder ports not available on the same station<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 52<br />

Function Port size Flow (Max) Circuit bar mounting<br />

3/2 NO-NC 1/8” - 1/4” 1.2C v<br />

add-a-unit<br />

stations for<br />

CBM052A bar<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

52A-xx-xxx-DM-Dxxx-xxx<br />

SOLENOID OPERATOR<br />

Port size<br />

Pilot air<br />

Single operator<br />

NO valve<br />

NC valve<br />

Double operator<br />

NO valve<br />

NC valve<br />

10<br />

2<br />

12<br />

10<br />

2<br />

12<br />

10<br />

2<br />

12<br />

10<br />

2<br />

12<br />

1/8” NPTF<br />

Internal<br />

3 1<br />

52A-31-COA-DM-DXXX-XXX<br />

52A-31-AOA-DM-DXXX-XXX<br />

3 1<br />

52A-11-AOA-DM-DXXX-XXX<br />

3 1<br />

52A-41-AOA-DM-DXXX-XXX<br />

3 1<br />

52A-21-AOA-DM-DXXX-XXX<br />

1/4” NPTF<br />

52A-31-BOA-DM-DXXX-XXX<br />

52A-11-BOA-DM-DXXX-XXX<br />

52A-41-BOA-DM-DXXX-XXX<br />

52A-21-BOA-DM-DXXX-XXX<br />

1/8” NPTF<br />

External<br />

52A-31-AOC-DM-DXXX-XXX<br />

52A-11-AOC-DM-DXXX-XXX<br />

52A-41-AOC-DM-DXXX-XXX<br />

52A-21-AOC-DM-DXXX-XXX<br />

1/4” NPTF<br />

52A-31-BOC-DM-DXXX-XXX<br />

52A-11-BOC-DM-DXXX-XXX<br />

52A-41-BOC-DM-DXXX-XXX<br />

52A-21-BOC-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X - X XX *<br />

XX Voltage<br />

X Wire length<br />

X<br />

Manual operator<br />

XX<br />

Electrical connection<br />

JA 120/60, 110/50<br />

A<br />

18” (Flying leads)<br />

1 Non-locking<br />

KA<br />

Square connector<br />

JB 240/60, 220/50<br />

J<br />

Connector<br />

2 Locking<br />

KD<br />

Square connector<br />

with light<br />

JC 24/60, 24/50<br />

x<br />

Other Options<br />

x<br />

Other Options<br />

JB<br />

Rectangular connector<br />

DA 24VDC (5.4 W)<br />

JD<br />

Rectangular connector<br />

with light<br />

FB 24VDC (1.8 W)<br />

BA<br />

Flying leads<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

CBM052A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard<br />

21 mm<br />

Spacing 26 mm<br />

(Rectangular connector)<br />

3/8” NPTF<br />

Internal<br />

CBM052A-01AEA-XX<br />

CBM052A-02AEA-XX<br />

External<br />

CBM052A-01CEA-XX<br />

CBM052A-02CEA-XX<br />

Number of stations (01=1 station)<br />

* * Other options available. Consult factory.<br />

O P T I O N S<br />

Note : add-a-unit stations available in lengths up to 4 stations (01, 02, 03 or 04).<br />

52A-31-AOA-DM-DXXX-XXX<br />

clic for memory spring (replace by 4).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 52<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum to 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

7.3 mm<br />

1.2C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04001. • Seal (x3) : 17015-01. • Mounting screw (x2) : 35043.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

CL CL CL CL<br />

40.0<br />

102.3<br />

XX<br />

CL CL CL CL<br />

1/8" OR 1/4"<br />

PORTS AVAILABLE<br />

ON THE BOTTOM OR SIDE<br />

23.2<br />

21.0<br />

10.0<br />

96.0<br />

35.0<br />

1 3<br />

12 12<br />

10<br />

10<br />

12<br />

10<br />

12<br />

10<br />

1<br />

3<br />

MODEL<br />

69.5<br />

52.5<br />

29.0<br />

14.5<br />

6.5 DIA.<br />

2 MTG.<br />

HOLES<br />

1 3<br />

38.2<br />

25.0<br />

YY<br />

21.0<br />

10.8<br />

16.0<br />

3/8" N.P.T.F.<br />

2 PLACES<br />

BOTH ENDS<br />

1/8" OPTIONAL<br />

COMMON EXTERNAL<br />

PILOT<br />

CL CL CL CL<br />

7.0<br />

TYP.<br />

YY<br />

19.5<br />

26<br />

XX<br />

113<br />

119.5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 52<br />

Function Port size Flow (Max) Individual mounting<br />

3/2 NO-NC 1/8” - 1/4” 1.2C v<br />

add-a-unit<br />

stations for<br />

CBP052A bar<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

52A-xx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Pilot air<br />

Single operator<br />

Double operator<br />

NO valve<br />

2<br />

10<br />

12<br />

NC valve<br />

2<br />

10<br />

12<br />

10<br />

NO valve<br />

2<br />

12<br />

10<br />

NC valve<br />

2<br />

12<br />

Internal<br />

3 1<br />

52A-33-OOA-DM-DXXX-XXX<br />

3 1<br />

52A-13-OOA-DM-DXXX-XXX<br />

3 1<br />

52A-43-OOA-DM-DXXX-XXX<br />

3 1<br />

52A-23-OOA-DM-DXXX-XXX<br />

External<br />

52A-33-OOC-DM-DXXX-XXX<br />

52A-13-OOC-DM-DXXX-XXX<br />

52A-43-OOC-DM-DXXX-XXX<br />

52A-23-OOC-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X - X XX *<br />

Voltage<br />

Wire length<br />

Manual operator<br />

XX X X XX<br />

JA 120/60, 110/50<br />

JB 240/60, 220/50<br />

JC 24/60, 24/50<br />

DA 24VDC (5.4 W)<br />

FB 24VDC (1.8 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

A 18” (Flying leads)<br />

1 Non-locking<br />

KA<br />

J Connector<br />

2 Locking<br />

KD<br />

x Other Options<br />

x Other Options<br />

JB<br />

JD<br />

BA<br />

xx<br />

CBP052A-xxxxx-xx<br />

Electrical connection<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

Port size (NPTF)<br />

Pilot air<br />

Spacing st<strong>and</strong>ard<br />

21 mm<br />

Spacing 26 mm<br />

(Rectangular connector)<br />

1/8” SIDE PORT<br />

Internal<br />

CBP052A-01AEA-XX<br />

CBP052A-02AEA-XX<br />

1/4” SIDE PORT<br />

CBP052A-01AED-XX<br />

CBP052A-02AED-XX<br />

1/8” SIDE PORT<br />

External<br />

CBP052A-01EEA-XX<br />

CBP052A-02EEA-XX<br />

1/4” SIDE PORT<br />

CBP052A-01EED-XX<br />

CBP052A-02EED-XX<br />

1/8” BOTTOM PORT<br />

Internal<br />

CBP052A-01BEA-XX<br />

CBP052A-02BEA-XX<br />

1/4” BOTTOM PORT<br />

CBP052A-01BED-XX<br />

CBP052A-02BED-XX<br />

1/8” BOTTOM PORT<br />

External<br />

CBP052A-01FEA-XX<br />

CBP052A-02FEA-XX<br />

1/4” BOTTOM PORT<br />

CBP052A-01FED-XX<br />

CBP052A-02FED-XX<br />

Number of stations (03=3 stations) ** Other options available. Consult factory.<br />

O P T I O N S<br />

Note : add-a-unit stations available in lengths up to<br />

4 stations (01, 02, 03 or 04).<br />

52A-33-OOA-DM-DXXX-XXX<br />

clic for memory spring (replace by 6).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 52<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum to 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

7.3 mm<br />

1.2C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35043 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-52003. • Seal (x3) : 17013-01. • Mounting screw (x2) : 35043.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

10.0<br />

CL<br />

CL<br />

CL<br />

CL<br />

1/8" OR 1/4"<br />

PORTS AVAILABLE<br />

ON THE BOTTOM OR SIDE<br />

40.0<br />

2<br />

2<br />

2<br />

2<br />

102.3<br />

XX<br />

CL<br />

CL<br />

CL<br />

CL<br />

23.2<br />

21.0<br />

10.0<br />

96.0<br />

1<br />

12<br />

12<br />

12<br />

12<br />

1<br />

MODEL<br />

69.5<br />

6.5 DIA.<br />

2 MTG.<br />

HOLES<br />

1<br />

3<br />

10<br />

10<br />

10<br />

10<br />

3<br />

52.5<br />

29.0<br />

14.5<br />

3<br />

2<br />

2<br />

2<br />

2<br />

ZZ<br />

38.2<br />

25.0<br />

YY<br />

21.0<br />

10.8<br />

16.0<br />

3/8" N.P.T.F.<br />

2 PLACES<br />

BOTH ENDS<br />

1/8" OPTIONAL<br />

COMMON EXTERNAL<br />

PILOT<br />

YY<br />

CL<br />

CL<br />

XX<br />

CL<br />

CL<br />

PORT<br />

7.0<br />

TYP.<br />

ZZ<br />

19.5<br />

113<br />

1/8”<br />

36.0<br />

26<br />

119.5<br />

1/4”<br />

40.0<br />

Note: Bottom & side cylinder ports not available on the same station<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Section 2 Options<br />

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Codification table for voltages / Wire length / Manual operator / Electrical connection<br />

VALVE CODE ➤<br />

D M - D XX X - X XX<br />

1 2 3 4<br />

OPTIONS AVAILABLE FOR<br />

- pilot operated valves 400, 52 & 92 Series<br />

Consult “Precautions”before use, installation or service of MAC Valves.


OPTIONS<br />

Back<br />

1. VOLTAGE<br />

- D XX X - X XX VOLTAGE<br />

DB 12 VDC (5.4 W)<br />

DC 12 VDC (7.5 W)<br />

DD 24 VDC (7.3 W)<br />

DE 12 VDC (12.7 W)<br />

DK 110 VDC (5.8 W)<br />

DJ 28 VDC (5.7 W)<br />

DL 64 VDC (6.0 W)<br />

DM 36 VDC (5.8 W)<br />

DN 6 VDC (6.0 W)<br />

DR 90 VDC (6,6 W)<br />

DS 110 VDC (7.3 W), 100 VDC (6.0 W)<br />

DT 75 VDC (5.6 W)<br />

DP 48 VDC (5.8 W)<br />

FA 12 VDC (1.8 W)<br />

FE 12 VDC (2.4 W)<br />

FF 24 VDC (2.4 W)<br />

JD 100/60, 100/50, 110/60<br />

2. WIRE LENGTH<br />

- D XX X - X XX WIRE LENGTH<br />

B 24”<br />

C 36”<br />

D 48”<br />

E 72”<br />

F 96”<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Back<br />

3. MANUAL OPERATOR<br />

- D XX X - X XX MANUAL OPERATOR<br />

0 No operator<br />

1 Non-locking recessed<br />

2 Locking recessed<br />

3 Non-locking extended<br />

4 Locking extended<br />

4. ELECTRICAL CONNECTION<br />

- D XX X - X XX ELECTRICAL CONNECTION<br />

BA Flying leads<br />

BK BA with protection diode<br />

BL BA with protection varistor<br />

CA 1/2" NPS conduit<br />

JB Rectangular connector<br />

JD Rectangular connector with light<br />

JM Rectangular connector, male only<br />

KA Square connector<br />

KB Square connector with protection diode<br />

KC Square connector with protection varistor<br />

KD Square connector with light<br />

KE Square connector with light <strong>and</strong> protection diode<br />

KF Square connector with light <strong>and</strong> protection varistor<br />

KJ Square connector (male only)<br />

KK Square connector with protection diode (male only)<br />

KL Square connector with protection varistor (male only)<br />

TA Dual tabs<br />

TB TA with protection diode<br />

TD TA with light<br />

TE TA with light <strong>and</strong> protection diode<br />

TJ Dual tabs (male only)<br />

TK TJ with protection diode<br />

TM TJ with light<br />

TN TJ with light <strong>and</strong> protection diode<br />

*DN Plug-in with diode<br />

*DP Plug-in with M.O.V.<br />

*DH Plug-in with diode & ground<br />

*DJ Plug-in with M.O.V & ground<br />

* These options only apply to the 92 series. All others are for the 400 <strong>and</strong> 52 series.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

PIN #6<br />

PIN #9<br />

MOD. SD09<br />

PIN #1<br />

PIN #5<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 9<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 7 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 2 common wires<br />

PIN #9<br />

PIN #15<br />

MOD. SD15<br />

PIN #1<br />

PIN #8<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 15<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 12 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 3 common wires<br />

PIN #14<br />

PIN #25<br />

MOD. SD25<br />

PIN #1<br />

PIN #13<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 25<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 20 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 5 common wires<br />

Note : Use desired MOD. number after circuit bar part number


O p t i o n s<br />

OPTIONS<br />

Connector termination details<br />

CONNECTOR<br />

SOL 1<br />

SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />

Single solenoid circuit bar<br />

SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />

CONNECTOR<br />

SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />

Double solenoid circuit bar<br />

SD09 SD15 SD25<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

8<br />

COMMON (+)<br />

13<br />

COMMON (+)<br />

21<br />

COMMON (+)<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

9<br />

COMMON (+)<br />

8<br />

SOL. 8<br />

8<br />

SOL. 8<br />

14<br />

COMMON (+)<br />

22<br />

COMMON (+)<br />

9<br />

SOL. 9<br />

9<br />

SOL. 9<br />

10 SOL. 10<br />

10 SOL. 10<br />

11<br />

SOL. 11<br />

11<br />

SOL. 11<br />

12 SOL. 12<br />

12 SOL. 12<br />

15<br />

COMMON (+)<br />

23<br />

COMMON (+)<br />

13<br />

SOL. 13<br />

14 SOL. 14<br />

15<br />

SOL. 15<br />

16 SOL. 16<br />

24<br />

COMMON (+)<br />

17<br />

18 SOL. 18<br />

19<br />

20 SOL. 20<br />

SOL. 17<br />

SOL. 19<br />

25<br />

COMMON (+)


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Circuit bar mounting<br />

non plug-in<br />

cylinder ports<br />

in base<br />

non plug-in<br />

cylinder ports<br />

in valve<br />

plug-in<br />

plug-in<br />

with F. C.<br />

plug-in<br />

with Pr. Reg.<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

add-on style<br />

plug-in<br />

add-on style<br />

plug-in<br />

with F. C.<br />

add-on style<br />

plug-in<br />

with Pr. Reg.<br />

add-on style<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

plug-in<br />

add-a-unit<br />

stations<br />

plug-in<br />

add-a-unit<br />

stations<br />

with F. C.<br />

plug-in<br />

add-a-unit<br />

stations<br />

with Pr. Reg.<br />

plug-in<br />

add-a-unit<br />

stations with<br />

F. C. <strong>and</strong> Pr. Reg.<br />

plug-in with<br />

pre-wired<br />

connector<br />

plug-in with<br />

F. C. <strong>and</strong><br />

pre-wired<br />

connector<br />

plug-in with<br />

Pr. Reg. <strong>and</strong><br />

pre-wired<br />

connector<br />

din rail,<br />

plug-in with<br />

pre-wired<br />

connector<br />

Manual operator<br />

Armature<br />

Coil<br />

Push Pin<br />

B A<br />

IN<br />

EA<br />

“D” seal<br />

4 Balanced poppets<br />

Valve spring<br />

EB<br />

SERIES FEATURES<br />

• High force MACSOLENOID ® .<br />

• 10mm direct operated.<br />

• # 10-32 or M5 ports.<br />

• Rated for lubricated or non-lubricated service.<br />

• Cylinder ports in valve or in circuit bar.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.093C v<br />

non plug-in<br />

cylinder ports<br />

in base<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-Gxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Valve less base<br />

Valve<br />

44B-LOO-GXXX-XXX<br />

Valve for use with<br />

external flow controls<br />

B A<br />

IN EA B EB A<br />

IN EA<br />

EB<br />

44B-MOO-GXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

A 18”<br />

1 Non-locking<br />

BA<br />

Flying leads<br />

DC 24VDC (1.8 W)<br />

C 36”<br />

BT<br />

Flying leads<br />

with light<br />

DD 24VDC (2.5 W)<br />

x<br />

Other Options<br />

KA<br />

Mini connector<br />

DF 24VDC (4.0 W)<br />

KT<br />

Mini connector<br />

with light<br />

xx<br />

Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

EBP44B-xxxx-xx<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

M5<br />

# 10-32<br />

EBP44B-001D-XX<br />

EBP44B-001B-XX<br />

EBP44B-002D-XX<br />

EBP44B-002B-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.093 C v , 2.5 W : 0.077 C v , 1,8 W : 0.057 C v , 1.0 W : 0.048 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 3.4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult Factory.<br />

DIMENSIONS<br />

M5 VALVE MTG. SCR.<br />

24,8<br />

59,5<br />

10,0<br />

B<br />

B<br />

16,25<br />

5,3<br />

15,0<br />

A<br />

A<br />

15,0<br />

71,2<br />

15,5<br />

2,5<br />

15,5<br />

10,5 5,0<br />

EA IN EB<br />

15,5<br />

10,5<br />

10,5<br />

1/8” NPTF PORTS<br />

18,3<br />

44,8<br />

5,5<br />

4 Ø 4,3<br />

56,3<br />

57,3<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC # 10-32 - 1/8” 0.093C v<br />

non plug-in<br />

cylinder ports<br />

in valve<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-Gxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Valve port size<br />

M5<br />

# 10-32<br />

Valve<br />

44B-ABA-GXXX-XXX<br />

44B-AAA-GXXX-XXX<br />

Valve for use with<br />

external flow controls<br />

B A<br />

IN EA B EB A<br />

IN EA<br />

EB<br />

44B-BBA-GXXX-XXX<br />

44B-BAA-GXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

A 18”<br />

1 Non-locking<br />

BA<br />

Flying leads<br />

DC 24VDC (1.8 W)<br />

C 36”<br />

BT<br />

Flying leads<br />

with light<br />

DD 24VDC (2.5 W)<br />

x<br />

Other Options<br />

KA<br />

Mini connector<br />

DF 24VDC (4.0 W)<br />

KT<br />

Mini connector<br />

with light<br />

xx<br />

Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

EBM44A-xxxx-xx<br />

Port size<br />

COMMON INLET & EXHAUST<br />

# 10-32<br />

1/8” NPTF<br />

EBM44A-001B-XX<br />

EBM44A-002A-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.093 C v , 2.5 W : 0.077 C v , 1,8 W : 0.057 C v , 1.0 W : 0.048 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 3.5 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit (M5) : M-44001-21. • Valve mounting kit (1/8") : M-44001-01. • Blanking plate : 30426-A.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult Factory.<br />

DIMENSIONS<br />

J<br />

K<br />

A B<br />

B<br />

Ø 4,2 MTG. HOLES<br />

H<br />

A<br />

D<br />

E<br />

F<br />

G<br />

14,0<br />

C L C L<br />

10,50<br />

4,00<br />

C<br />

38,5<br />

Port size<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

H<br />

J<br />

K<br />

1/8”<br />

16.0<br />

47.5<br />

69.2<br />

8.5<br />

24.0<br />

39.5<br />

48.0<br />

8.0<br />

31.85<br />

16.15<br />

M5<br />

12.0<br />

43.5<br />

63.2<br />

5.0<br />

17.0<br />

29.0<br />

34.0<br />

6.0<br />

23.00<br />

11.00<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.09C v plug-in<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-LOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

M5<br />

# 10-32<br />

ECD044B-00xxx-AOxx<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECD044B-001AD-AOXX<br />

ECD044B-001AB-AOXX<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECD044B-002AD-AOXX<br />

ECD044B-002AB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

clic for multi-pin connector option (9, 15 or 25).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

11.4<br />

18.5<br />

61.2<br />

L<br />

24.5<br />

13.8<br />

90.7<br />

26.0<br />

38.6<br />

84.0<br />

33.5<br />

23.0<br />

40.0<br />

32.3<br />

19.9<br />

5.0<br />

13.0<br />

20.1<br />

20.5<br />

24.9<br />

17.7<br />

22.5<br />

33.0<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

55.5<br />

3<br />

66.0<br />

4<br />

76.5<br />

5<br />

87.0<br />

6<br />

97.5<br />

7 8 9 10<br />

108.0 118.5 129.0 139.5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.08C v<br />

plug-in<br />

with F. C.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-MOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />

Port size<br />

M5<br />

# 10-32<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECD044B-005AD-AOXX<br />

ECD044B-005AB-AOXX<br />

ECD044B-00xxx-AOxx<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECD044B-006AD-AOXX<br />

ECD044B-006AB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

clic for multi-pin connector option (9, 15 or 25).<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Flow control needle (x2): N-44002.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

11.4<br />

18.5<br />

61.2<br />

24.5<br />

13.8<br />

90.7<br />

26.0<br />

38.6<br />

84.0<br />

33.5<br />

23.0<br />

40.0<br />

32.3<br />

19.9<br />

5.0<br />

17.7<br />

13.0<br />

20.1<br />

20.5<br />

24.9<br />

22.5<br />

33.0<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

55.5<br />

3<br />

66.0<br />

4<br />

76.5<br />

5<br />

87.0<br />

6<br />

97.5<br />

7 8 9 10<br />

108.0 118.5 129.0 139.5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.08C v<br />

plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-LOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS** (to be ordered separately)<br />

ECD044B-00xxx-AOxx<br />

Port size<br />

M5<br />

# 10-32<br />

Bottom cylinder ports<br />

(10,5 mm)<br />

ECD044B-004AD-A0-XX<br />

ECD044B-004AB-A0-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

clic for multi-pin connector option (9, 15 or 25).<br />

** Pressure Regulators :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Pressure range regulators : (0-100 PSI).<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

61.2<br />

18.5<br />

11.4<br />

144.3<br />

24.5<br />

13.8<br />

90.7<br />

26.0<br />

38.6<br />

84.0<br />

32.3<br />

19.9<br />

13.0<br />

20.5<br />

33.5<br />

20.1<br />

24.9<br />

23.0<br />

40.0<br />

5.0<br />

17.7<br />

22.5<br />

33.0<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

55.5<br />

3<br />

66.0<br />

4<br />

76.5<br />

5<br />

87.0<br />

6<br />

97.5<br />

7 8 9 10<br />

108.0 118.5 129.0 139.5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.07C v<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-MOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

ECD044B-00xxx-AOxx<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS** (pressure regulators to be ordered separately)<br />

Port size<br />

M5<br />

# 10-32<br />

Bottom cylinder ports<br />

(10,5 mm)<br />

ECD044B-007AD-A0-XX<br />

ECD044B-007AB-A0-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

clic for multi-pin connector option (9, 15 or 25).<br />

** Pressure Regulators :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.07 C v , 2.5 W : 0.06 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Pressure range regulators : (0-100 PSI).<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

L<br />

61.2<br />

18.5<br />

11.4<br />

24.5<br />

144.3<br />

13.8<br />

90.7<br />

26.0<br />

38.6<br />

84.0<br />

32.3<br />

19.9<br />

13.0<br />

20.5<br />

33.5<br />

20.1<br />

24.9<br />

23.0<br />

40.0<br />

5.0<br />

17.7<br />

22.5<br />

33.0<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

55.5<br />

3<br />

66.0<br />

4<br />

76.5<br />

5<br />

87.0<br />

6<br />

97.5<br />

7 8 9 10<br />

108.0 118.5 129.0 139.5<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.09C v<br />

add-on style<br />

plug-in<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-LOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

M5<br />

# 10-32<br />

ECD044B-00xxx-AOxx<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECD044B-001BD-AOXX<br />

ECD044B-001BB-AOXX<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECD044B-002BD-AOXX<br />

ECD044B-002BB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

clic for multi-pin connector option (9, 15 or 25).<br />

add-a-unit stations may be added to above bars.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

24.5<br />

41.5<br />

10.5<br />

10.5<br />

15.5<br />

20.0<br />

18.5<br />

11.3<br />

13.8<br />

26.0<br />

EXH<br />

90.7<br />

38.6<br />

IN<br />

64.2<br />

EXH<br />

84.0<br />

60.5<br />

B<br />

A A<br />

B<br />

B<br />

A<br />

A<br />

A<br />

19.9<br />

20.9<br />

31.3<br />

32.3<br />

60.5<br />

17.7<br />

5.0<br />

A<br />

A<br />

13.0<br />

B<br />

B B<br />

B<br />

20.5<br />

10.5<br />

25.0<br />

20.7<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.08C v<br />

add-on style<br />

plug-in<br />

with F. C.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-MOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />

Port size<br />

M5<br />

# 10-32<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECD044B-005BD-AOXX<br />

ECD044B-005BB-AOXX<br />

ECD044B-00xxx-AOxx<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECD044B-006BD-AOXX<br />

ECD044B-006BB-AOXX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

clic for multi-pin connector option (9, 15 or 25).<br />

add-a-unit stations may be added to above bars.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Flow control needle (x2): N-44002.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

41.5<br />

15.0<br />

15.0<br />

15.5<br />

24.5<br />

20.0<br />

18.5<br />

11.3<br />

13.8<br />

90.7<br />

26.0<br />

EXH<br />

38.6<br />

IN<br />

84.0<br />

64.2<br />

EXH<br />

60.5 17.7 5.0<br />

60.5<br />

A<br />

A<br />

A<br />

B<br />

A<br />

B<br />

B<br />

A<br />

19.9<br />

20.9<br />

31.3<br />

32.3<br />

B<br />

B<br />

A<br />

A<br />

B<br />

B<br />

13.0<br />

20.5<br />

10.9<br />

20.6<br />

25.0<br />

10.5<br />

4.4<br />

5.1<br />

23.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.08C v<br />

add-on style<br />

plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-LOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS** (to be ordered separately)<br />

ECD044B-00xxx-AOxx<br />

Port size<br />

M5<br />

# 10-32<br />

Bottom cylinder ports<br />

(10,5 mm)<br />

ECD044B-004BD-A0-XX<br />

ECD044B-004BB-A0-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

clic for multi-pin connector option (9, 15 or 25).<br />

add-a-unit stations may be added to above bars.<br />

** Pressure Regulators :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Pressure range regulators : (0-100 PSI).<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

41.5<br />

10.5<br />

10.5<br />

24.5<br />

20.0<br />

18.5<br />

11.3<br />

15.5<br />

144.3<br />

13.8<br />

90.7<br />

38.6<br />

64.2<br />

26.0<br />

IN<br />

EXH<br />

EXH<br />

25.0<br />

20.5<br />

13.0<br />

10.5<br />

84.0<br />

K<br />

C<br />

O<br />

L<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

- +<br />

A<br />

K<br />

O C<br />

L<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

-<br />

+<br />

A<br />

A<br />

A<br />

60.5<br />

17.7<br />

5.0<br />

60.5<br />

B<br />

B<br />

B<br />

19.9<br />

20.9<br />

31.3<br />

32.3<br />

20.7<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.07C v<br />

plug-in<br />

with Pr. Reg.<br />

add-on style<br />

<strong>and</strong> F. C.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-MOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

ECD044B-00xxx-AOxx<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS** (pressure regulators to be ordered separately)<br />

Port size<br />

M5<br />

# 10-32<br />

Bottom cylinder ports<br />

(10,5 mm)<br />

ECD044B-007BD-A0-XX<br />

ECD044B-007BB-A0-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

clic for multi-pin connector option (9, 15 or 25).<br />

add-a-unit stations may be added to above bars.<br />

** Pressure Regulators :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


IN<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.07 C v , 2.5 W : 0.06 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Pressure range regulators : (0-100 PSI).<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

87.0<br />

144.3<br />

90.7<br />

26.0<br />

13.8<br />

EXH<br />

10.5<br />

4.4<br />

38.6<br />

5.1<br />

84.0<br />

64.2<br />

EXH<br />

25.0<br />

20.5<br />

13.0<br />

41.5<br />

15.5<br />

11.4<br />

15.0<br />

15.0<br />

18.5<br />

60.5<br />

17.7<br />

5.0<br />

20.0<br />

24.5<br />

60.5<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

19.9 20.9 31.3 32.3<br />

10.9<br />

20.6<br />

23.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 M5 - #10-32 0.09C v<br />

plug-in<br />

add-a-unit<br />

stations<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-LOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

ECD044B-00xxx-AOxx<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

M5<br />

# 10-32<br />

ECD044B-001CD-AOXX<br />

ECD044B-001CB-AOXX<br />

ECD044B-002CD-AOXX<br />

ECD044B-002CB-AOXX<br />

Number of stations (03=3 stations) - Maximum length is 4 stations<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

when add-a-unit stations are added to bars with a multi-pin connector,<br />

MOD. SD03 should be included with add-a-unit model number.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

24.5<br />

41.5<br />

10.5<br />

10.5<br />

15.5<br />

20.0<br />

18.5<br />

11.3<br />

13.8<br />

26.0<br />

EXH<br />

90.7<br />

38.6<br />

IN<br />

64.2<br />

EXH<br />

84.0<br />

60.5<br />

B<br />

A A<br />

B<br />

B<br />

A<br />

A<br />

A<br />

19.9<br />

20.9<br />

31.3<br />

32.3<br />

60.5<br />

17.7<br />

5.0<br />

A<br />

A<br />

13.0<br />

B<br />

B B<br />

B<br />

20.5<br />

10.5<br />

25.0<br />

20.7<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 M5 - #10-32 0.08C v<br />

add-a-unit<br />

stations<br />

plug-in<br />

with F. C.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-MOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS<br />

Port size<br />

Side cylinder ports<br />

ECD044B-00xxx-AOxx<br />

Bottom cylinder ports<br />

M5<br />

# 10-32<br />

ECD044B-005CD-AOXX<br />

ECD044B-005CB-AOXX<br />

ECD044B-006CD-AOXX<br />

ECD044B-006CB-AOXX<br />

Number of stations (03=3 stations) - Maximum length is 4 stations<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

when add-a-unit stations are added to bars with a multi-pin connector,<br />

MOD. SD03 should be included with add-a-unit model number.<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Flow control needle (x2): N-44002.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

41.5<br />

15.0<br />

15.0<br />

15.5<br />

24.5<br />

20.0<br />

18.5<br />

11.3<br />

13.8<br />

90.7<br />

26.0<br />

EXH<br />

38.6<br />

IN<br />

84.0<br />

64.2<br />

EXH<br />

60.5 17.7 5.0<br />

60.5<br />

A<br />

A<br />

A<br />

B<br />

A<br />

B<br />

B<br />

A<br />

19.9<br />

20.9<br />

31.3<br />

32.3<br />

B<br />

B<br />

A<br />

A<br />

B<br />

B<br />

13.0<br />

20.5<br />

10.9<br />

20.6<br />

25.0<br />

10.5<br />

4.4<br />

5.1<br />

23.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 M5 - #10-32 0.08C v<br />

add-a-unit<br />

stations<br />

plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-LOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />

Port size<br />

M5<br />

# 10-32<br />

ECD044B-00xxx-AOxx<br />

Bottom cylinder ports<br />

(10,5 mm)<br />

ECD044B-004CD-AOXX<br />

ECD044B-004CB-AOXX<br />

Number of stations (03=3 stations) - Maximum length is 4 stations<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

when add-a-unit stations are added to bars with a multi-pin connector,<br />

MOD. SD03 should be included with add-a-unit model number.<br />

** Regulator ordered separately-see below :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Pressure range regulators : (0-100 PSI).<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

24.5<br />

20.0<br />

41.5<br />

10.5<br />

10.5<br />

18.5<br />

11.3<br />

15.5<br />

144.3<br />

13.8<br />

90.7<br />

38.6<br />

64.2<br />

26.0<br />

IN<br />

EXH<br />

EXH<br />

25.0<br />

20.5<br />

13.0<br />

10.5<br />

84.0<br />

K<br />

C<br />

O<br />

L<br />

K<br />

C<br />

O<br />

L<br />

- +<br />

- +<br />

A<br />

K<br />

O C<br />

L<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

-<br />

+<br />

A<br />

A<br />

A<br />

60.5<br />

17.7<br />

5.0<br />

60.5<br />

B<br />

B<br />

B<br />

19.9<br />

20.9<br />

31.3<br />

32.3<br />

20.7<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 M5 - #10-32 0.07C v<br />

add-a-unit<br />

stations with<br />

plug-in<br />

F. C. <strong>and</strong> Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-MOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

ECD044B-00xxx-AOxx<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS AND PRESSURE REGULATORS ** (pressure regulators to be ordered separately)<br />

Port size<br />

M5<br />

# 10-32<br />

Bottom cylinder ports<br />

(10,5 mm)<br />

ECD044B-007CD-AOXX<br />

ECD044B-007CB-AOXX<br />

Number of stations (03=3 stations) - Maximum length is 4 stations<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

when add-a-unit stations are added to bars with a multi-pin connector,<br />

MOD. SD03 should be included with add-a-unit model number.<br />

** Regulator ordered separately-see below :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

Consult “Precautions” before use, installation or service of MAC Valves.


IN<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.07 C v , 2.5 W : 0.06 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Pressure range regulators : (0-100 PSI).<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator: N-44003.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP Threads.<br />

DIMENSIONS<br />

87.0<br />

144.3<br />

90.7<br />

26.0<br />

13.8<br />

EXH<br />

10.5<br />

4.4<br />

38.6<br />

5.1<br />

84.0<br />

64.2<br />

EXH<br />

25.0<br />

20.5<br />

13.0<br />

41.5<br />

15.5<br />

11.4<br />

15.0<br />

15.0<br />

18.5<br />

60.5<br />

17.7<br />

5.0<br />

20.0<br />

24.5<br />

60.5<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

K<br />

+<br />

O C<br />

L<br />

-<br />

19.9 20.9 31.3 32.3<br />

10.9<br />

20.6<br />

23.0<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32, 0.10C v<br />

4 mm tube receptacle<br />

plug-in with<br />

pre-wired<br />

connector<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-LOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

ECF44B-00xxx-xxxx<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

Port size<br />

M5<br />

# 10-32<br />

4 mm tube receptacle<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECF44B-00BDA-ZZXX<br />

ECF44B-00BBA-ZZXX<br />

ECF44B-00BEA-ZZXX<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECF44B-00CDA-ZZXX<br />

ECF44B-00CBA-ZZXX<br />

---------<br />

Number of stations (03=3 stations)<br />

** Other options available Consult factory.<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

ZZ Connector<br />

LA 9 Pin Sub D*<br />

LB 15 Pin Sub D*<br />

LC 25 Pin Sub D*<br />

LD 10 Pin Ribbon Cable**<br />

LE 16 Pin Ribbon Cable**<br />

LF 20 Pin Ribbon Cable**<br />

LG 26 Pin Ribbon Cable**<br />

LH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

Consult “Precautions” before use, installation or service of MAC Valves.<br />

L=Left Side; R=Right Side<br />

ZZ Connector<br />

RA 9 Pin Sub D*<br />

RB 15 Pin Sub D*<br />

RC 25 Pin Sub D*<br />

RD 10 Pin Ribbon Cable**<br />

RE 16 Pin Ribbon Cable**<br />

RF 20 Pin Ribbon Cable**<br />

RG 26 Pin Ribbon Cable**<br />

RH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

* MIL. Spec; MIL-C-24308<br />

** MIL. Spec; MIL-C-83503<br />

Note: Left <strong>and</strong> right end is determined by facing conduit passage.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP threads.<br />

DIMENSIONS<br />

83.5<br />

8.7<br />

3.5<br />

2.9<br />

13.3<br />

EXH<br />

76.2<br />

70.4<br />

14.9<br />

13.6<br />

EXH<br />

IN<br />

10.5 17.4<br />

22.0<br />

A<br />

A<br />

10.6<br />

10.5<br />

49.5<br />

63.5<br />

2.8<br />

13.2<br />

51.0<br />

B<br />

B<br />

B<br />

B<br />

A<br />

A<br />

A<br />

B<br />

A A<br />

B<br />

B<br />

A<br />

B<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.09C v<br />

F. C. <strong>and</strong><br />

pre-wired<br />

plug-in with<br />

connector<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-MOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR WITH FLOW CONTROLS **<br />

Port size<br />

M5<br />

# 10-32<br />

ECF44B-00xxx-xxxx<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECF44B-00EDA-ZZXX<br />

ECF44B-00EBA-ZZXX<br />

Number of stations (03=3 stations)<br />

** Other options available Consult factory.<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

ZZ Connector<br />

LA 9 Pin Sub D*<br />

LB 15 Pin Sub D*<br />

LC 25 Pin Sub D*<br />

LD 10 Pin Ribbon Cable**<br />

LE 16 Pin Ribbon Cable**<br />

LF 20 Pin Ribbon Cable**<br />

LG 26 Pin Ribbon Cable**<br />

LH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

Consult “Precautions” before use, installation or service of MAC Valves.<br />

L=Left Side; R=Right Side<br />

ZZ Connector<br />

RA 9 Pin Sub D*<br />

RB 15 Pin Sub D*<br />

RC 25 Pin Sub D*<br />

RD 10 Pin Ribbon Cable**<br />

RE 16 Pin Ribbon Cable**<br />

RF 20 Pin Ribbon Cable**<br />

RG 26 Pin Ribbon Cable**<br />

RH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

* MIL. Spec; MIL-C-24308<br />

** MIL. Spec; MIL-C-83503<br />

Note: Left <strong>and</strong> right end is determined by facing conduit passage.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Flow control needle (x2): N-44002.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP threads.<br />

DIMENSIONS<br />

83.5<br />

76.2<br />

70.4<br />

13.3<br />

14.9<br />

13.6<br />

EXH EXH<br />

IN<br />

22.0<br />

B<br />

B<br />

B<br />

B<br />

49.5<br />

63.5<br />

2.9<br />

3.5<br />

8.7<br />

A<br />

A<br />

A<br />

A<br />

10.6<br />

51.0<br />

10.5<br />

17.4<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32 0.09C v<br />

Pr. Reg. <strong>and</strong><br />

pre-wired<br />

plug-in with<br />

connector<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-LOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER CIRCUIT BAR FOR PRESSURE REGULATORS ** (to be ordered separately)<br />

Port size<br />

M5<br />

# 10-32<br />

ECF44B-00xxx-xxxx<br />

Bottom cylinder ports<br />

(10.5 mm)<br />

ECF44B-00GDA-ZZXX<br />

ECF44B-00GBA-ZZXX<br />

Number of stations (03=3 stations)<br />

** Other options available Consult factory.<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

** Pressure Regulators :<br />

PR44A-AOxx<br />

Y=A (no gage port)<br />

Y=B (with gage port)<br />

X=A (0 to 100 PSI)<br />

X=B (0 to 60 PSI)<br />

X=C (0 to 40 PSI)<br />

X=D (0 to 15 PSI)<br />

ZZ Connector<br />

LA 9 Pin Sub D*<br />

LB 15 Pin Sub D*<br />

LC 25 Pin Sub D*<br />

LD 10 Pin Ribbon Cable**<br />

LE 16 Pin Ribbon Cable**<br />

LF 20 Pin Ribbon Cable**<br />

LG 26 Pin Ribbon Cable**<br />

LH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

Consult “Precautions” before use, installation or service of MAC Valves.<br />

L=Left Side; R=Right Side<br />

ZZ Connector<br />

RA 9 Pin Sub D*<br />

RB 15 Pin Sub D*<br />

RC 25 Pin Sub D*<br />

RD 10 Pin Ribbon Cable**<br />

RE 16 Pin Ribbon Cable**<br />

RF 20 Pin Ribbon Cable**<br />

RG 26 Pin Ribbon Cable**<br />

RH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

* MIL. Spec; MIL-C-24308<br />

** MIL. Spec; MIL-C-83503<br />

Note: Left <strong>and</strong> right end is determined by facing conduit passage.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.09 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Pressure range regulator (0-100 PSI)<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Blanking plate regulator : N-44003.<br />

• Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP threads.<br />

DIMENSIONS<br />

83.5<br />

136.5<br />

70.4<br />

13.3<br />

14.9<br />

13.6<br />

EXH EXH<br />

IN<br />

22.0<br />

K<br />

O C<br />

L<br />

K<br />

O C<br />

L<br />

K<br />

O C<br />

L<br />

K<br />

O C<br />

L<br />

-<br />

+<br />

-<br />

+<br />

-<br />

+<br />

-<br />

+<br />

B<br />

B<br />

B<br />

B<br />

49.5<br />

63.5<br />

2.9<br />

3.5<br />

8.7<br />

A<br />

A<br />

A<br />

A<br />

10.6<br />

51.0<br />

10.5<br />

17.4<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 44<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2, 3/2 NO-NC M5 - #10-32, 0.10C v<br />

4 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. 10 mm valve, direct solenoid operated.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Flow is specifically adjusted on each valve.<br />

7. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

din rail,<br />

plug-in with<br />

pre-wired<br />

connector<br />

HOW TO ORDER<br />

44B-xxx-GxxO-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

Single operator<br />

B<br />

A<br />

Valve less base<br />

EB<br />

IN EA<br />

44B-LOO-GXXO-XXX<br />

SOLENOID OPERATOR ➤<br />

G XX O- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (1.0 W)<br />

DC 24VDC (1.8 W)<br />

DD 24VDC (2.5 W)<br />

1 Non-locking<br />

DF 24VDC (4.0 W)<br />

DV Plug-in with light <strong>and</strong> suppression diode<br />

xx Other Options<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

ECF44B-00xxx-xxxx<br />

DJ<br />

DT<br />

DE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

Port size<br />

M5<br />

# 10-32<br />

4 mm tube receptacle<br />

Side cylinder ports<br />

(10.5 mm)<br />

ECF44B-00BDB-ZZXX<br />

ECF44B-00BBB-ZZXX<br />

ECF44B-00BEB-ZZXX<br />

Number of stations (03=3 stations)<br />

Din rail spec. (EN50 022)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

ZZ Connector<br />

LA 9 Pin Sub D*<br />

LB 15 Pin Sub D*<br />

LC 25 Pin Sub D*<br />

LD 10 Pin Ribbon Cable**<br />

LE 16 Pin Ribbon Cable**<br />

LF 20 Pin Ribbon Cable**<br />

LG 26 Pin Ribbon Cable**<br />

LH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

Consult “Precautions” before use, installation or service of MAC Valves.<br />

L=Left Side; R=Right Side<br />

ZZ Connector<br />

RA 9 Pin Sub D*<br />

RB 15 Pin Sub D*<br />

RC 25 Pin Sub D*<br />

RD 10 Pin Ribbon Cable**<br />

RE 16 Pin Ribbon Cable**<br />

RF 20 Pin Ribbon Cable**<br />

RG 26 Pin Ribbon Cable**<br />

RH 3/8” NPSM Conduit Port<br />

St<strong>and</strong>ard Base Wires<br />

* MIL. Spec; MIL-C-24308<br />

** MIL. Spec; MIL-C-83503<br />

Note: Left <strong>and</strong> right end is determined by facing conduit passage.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 44<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 4 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

1.8 mm<br />

4 W : 0.10 C v , 2.5 W : 0.08 C v , 1,8 W : 0.06 C v , 1.0 W : 0.05 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

4 W - 2.5 W - 1.8 W - 1.0 W<br />

Energize : 4 ms<br />

De-energize : 1.5 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Valve mounting kit : N-44001-03. • Blanking plate : M-44003. • Base wire Plug-in protector : 24180.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. • BSPP threads.<br />

DIMENSIONS<br />

83.5<br />

8.7<br />

3.5<br />

2.9<br />

76.2<br />

70.4<br />

13.3<br />

14.9<br />

13.6<br />

EXH EXH<br />

IN<br />

54.4<br />

49.5<br />

63.5<br />

60.5<br />

9.8<br />

42.6<br />

10.5<br />

2.8<br />

13.2<br />

5.4<br />

B<br />

B<br />

B<br />

B<br />

A<br />

A<br />

A<br />

A<br />

Consult “Precautions” before use, installation or service of MAC Valves.


Section 2 Options<br />

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Codification table for voltages / Manual operator / Electrical connection<br />

VALVE CODE ➤<br />

- G XX X - X XX<br />

1 2 3 4<br />

OPTIONS AVAILABLE FOR<br />

- solenoid valves 34 & 44 Series<br />

Consult “Precautions”before use, installation or service of MAC Valves.


OPTIONS<br />

Back<br />

1. VOLTAGE (type 34 Series)<br />

-G XX X - X XX VOLTAGE<br />

DC 24 VDC (1,8 W)<br />

DD 24 VDC (2,5 W)<br />

DE 24 VDC (3,0 W)<br />

DF 24 VDC (4,0 W)<br />

DJ 12 VDC (1,8 W)<br />

DK 12 VDC (2,5 W)<br />

DM 12 VDC (3,0 W)<br />

DN 12 VDC (4,0 W)<br />

1. VOLTAGE (type 44 Series)<br />

-G XX X - X XX VOLTAGE<br />

DA 24 VDC (1,0 W)<br />

DC 24 VDC (1,8 W)<br />

DD 24 VDC (2,5 W)<br />

DF 24 VDC (4,0 W)<br />

DG 12 VDC (1,0 W)<br />

DJ 12 VDC (1,8 W)<br />

DK 12 VDC (2,5 W)<br />

DN 12 VDC (4,0 W)<br />

2. WIRE LENGTH (Common options for 34 & 44 Series)<br />

-G XX X - X XX WIRE LENGTH<br />

A 18”<br />

B 24”<br />

C 36”<br />

D 48”<br />

E 72”<br />

F 96”<br />

G 120”<br />

H 144”<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Back<br />

3. MANUAL OPERATOR (COMMON OPTIONS FOR 34 & 44 SERIES)<br />

-G XX X - X XX MANUAL OPERATOR<br />

1 Non-locking recessed<br />

3 Non-locking extended<br />

4. ELECTRICAL CONNECTION (COMMON OPTIONS FOR 34 & 44 SERIES)<br />

-G XX X - X XX NO CONNECTOR<br />

BA Flying leads<br />

BB BA with ground wire<br />

BC BA with light<br />

BD BA with light <strong>and</strong> ground wire<br />

BE BA with suppression diode<br />

BF BA with suppression diode <strong>and</strong> ground wire<br />

BG BA with suppression diode <strong>and</strong> light<br />

BH BA with suppression diode, light <strong>and</strong> ground wire<br />

BN BA with suppression diode <strong>and</strong> blocking diode<br />

BP BA with suppression diode, blocking diode <strong>and</strong> ground wire<br />

BR BA with suppression diode, blocking diode <strong>and</strong> light<br />

BS BA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />

BT BA with light<br />

BU BA with light <strong>and</strong> ground wire<br />

BV BA with suppression diode <strong>and</strong> light<br />

BW BA with suppression diode, light <strong>and</strong> ground wire<br />

BX BA with suppression diode, blocking diode <strong>and</strong> light<br />

BY BA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />

-G XX X - X XX PLUG-IN CONNECTOR<br />

KA Mini connector with flying leads<br />

KB KA with ground wire<br />

KE KA with suppression diode<br />

KF KA with suppression diode <strong>and</strong> ground wire<br />

KJ Mini connector for KA option<br />

KM Mini connector for KB option<br />

KN KA with suppression diode <strong>and</strong> blocking diode<br />

KP KA with suppression diode, blocking diode <strong>and</strong> ground wire<br />

KT KA with light<br />

KU KA with light <strong>and</strong> ground wire<br />

KV KA with suppression diode <strong>and</strong> light<br />

KW KA with suppression diode, light <strong>and</strong> ground wire<br />

KX KA with suppression diode, blocking diode <strong>and</strong> light<br />

KY KA with suppression diode, blocking diode, light <strong>and</strong> ground wire<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

PIN #6<br />

PIN #9<br />

MOD. SD09<br />

PIN #1<br />

PIN #5<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 9<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 7 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 2 common wires<br />

PIN #9<br />

PIN #15<br />

MOD. SD15<br />

PIN #1<br />

PIN #8<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 15<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 12 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 3 common wires<br />

PIN #14<br />

PIN #25<br />

MOD. SD25<br />

PIN #1<br />

PIN #13<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 25<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 20 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 5 common wires<br />

Note : Use desired MOD. number after circuit bar part number


O p t i o n s<br />

OPTIONS<br />

Connector termination details<br />

CONNECTOR<br />

SOL 1<br />

SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />

Single solenoid circuit bar<br />

SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />

CONNECTOR<br />

SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />

Double solenoid circuit bar<br />

SD09 SD15 SD25<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

8<br />

COMMON (+)<br />

13<br />

COMMON (+)<br />

21<br />

COMMON (+)<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

9<br />

COMMON (+)<br />

8<br />

SOL. 8<br />

8<br />

SOL. 8<br />

14<br />

COMMON (+)<br />

22<br />

COMMON (+)<br />

9<br />

SOL. 9<br />

9<br />

SOL. 9<br />

10 SOL. 10<br />

10 SOL. 10<br />

11<br />

SOL. 11<br />

11<br />

SOL. 11<br />

12 SOL. 12<br />

12 SOL. 12<br />

15<br />

COMMON (+)<br />

23<br />

COMMON (+)<br />

13<br />

SOL. 13<br />

14 SOL. 14<br />

15<br />

SOL. 15<br />

16 SOL. 16<br />

24<br />

COMMON (+)<br />

17<br />

18 SOL. 18<br />

19<br />

20 SOL. 20<br />

SOL. 17<br />

SOL. 19<br />

25<br />

COMMON (+)


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Circuit bar mounting<br />

non plug-in<br />

with or<br />

without F. C.<br />

non plug-in<br />

with Pr. Reg.<br />

non plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

plug-in<br />

plug-in<br />

with side<br />

Pr. Reg.<br />

plug-in<br />

with s<strong>and</strong>wich<br />

Pr. Reg.<br />

plug-in<br />

with F. C.<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

plug-in<br />

with integral<br />

terminal strip<br />

plug-in with<br />

integral terminal<br />

strip <strong>and</strong><br />

side Pr. Reg.<br />

plug-in with<br />

integral terminal<br />

strip <strong>and</strong><br />

s<strong>and</strong>wich Pr. Reg.<br />

plug-in with<br />

integral terminal<br />

strip with F. C.<br />

plug-in with<br />

integral terminal<br />

strip with<br />

Pr. Reg. <strong>and</strong> F. C.<br />

Manual operator<br />

Armature<br />

Spool push pin<br />

Solenoid<br />

A<br />

EXH.<br />

Spring biased moveable<br />

pole piece<br />

Valve spring<br />

IN<br />

Bonded balanced poppets<br />

B<br />

SERIES FEATURES<br />

• Patented MACSOLENOID ® for fastest possible response times.<br />

• Extremely high cycle rate capability.<br />

• Rated for lubricated or non-lubricated service.<br />

• Various solenoid enclosures <strong>and</strong> plug-in connectors.<br />

• Low wattage DC solenoids - down to 1.8 watts.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

non plug-in<br />

with or<br />

without F. C.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Single operator<br />

A B<br />

A<br />

B<br />

Double operator<br />

(Minimum DC wattage 5,4W)<br />

A<br />

A B<br />

B<br />

EXH<br />

IN<br />

45A-L00-DXXX-XXX<br />

EXH<br />

IN<br />

45A-N00-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

A<br />

J<br />

18” (Flying leads)<br />

Connector<br />

HOW TO ORDER CIRCUIT BAR ** (WITHOUT FLOW CONTROLS)<br />

x<br />

Other Options<br />

1 Non-locking Recessed<br />

KA Square connector<br />

2 Locking Recessed<br />

KD Square connector<br />

with light<br />

x Other Options<br />

BA Flying leads<br />

xx Other Options<br />

EBM45A-xxxx-xx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder<br />

ports<br />

Bottom cylinder<br />

ports<br />

1/8” NPTF<br />

21<br />

EBM45A-001A-XX<br />

EBM45A-002A-XX<br />

# 10-32 UNF<br />

21<br />

EBM45A-001B-XX<br />

EBM45A-002B-XX<br />

HOW TO ORDER CIRCUIT BAR ** (WITH FLOW CONTROLS)<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder<br />

ports<br />

Bottom cylinder<br />

ports<br />

1/8” NPTF<br />

26<br />

EBM45A-015A-XX<br />

EBM45A-016A-XX<br />

# 10-32 UNF<br />

26<br />

EBM45A-015B-XX<br />

EBM45A-016B-XX<br />

1/8” NPTF<br />

40<br />

EBM45A-025A-XX<br />

EBM45A-026A-XX<br />

# 10-32 UNF<br />

40<br />

EBM45A-025B-XX<br />

EBM45A-026B-XX<br />

Number of stations (03=3 stations)<br />

** Other options available Consult factory.<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

VALVE BLANKING PLATE<br />

21,0<br />

"A"<br />

21,0<br />

94,1<br />

25,6<br />

VALVE BLANKING<br />

PLATE<br />

21,0<br />

"A"<br />

21,0<br />

33,0<br />

21,5<br />

~24.5<br />

29,5<br />

B<br />

C L<br />

C L<br />

C L<br />

B B<br />

A A A<br />

7,5<br />

17,0<br />

5,0<br />

11,0<br />

50,5<br />

22,0<br />

IN<br />

EXH<br />

5,1 LOCKING<br />

RECESSED OPERA-<br />

TOR<br />

35,5<br />

B<br />

C L<br />

C L<br />

C L<br />

B B<br />

A A A<br />

5,5<br />

11,0<br />

C<br />

B<br />

65,6<br />

OPTIONAL PRESSURE<br />

SENSING PORT<br />

(#10-32 UNF)<br />

50,5<br />

22,0<br />

18,6<br />

IN<br />

17,0<br />

32,0<br />

40,0<br />

EXH<br />

11,5<br />

~24.5<br />

5,1 LOCKING<br />

RECESSED<br />

OPERATOR<br />

1/8” 2 PORTS<br />

BOTH ENDS<br />

Ø 5,2 MTG.<br />

HOLES<br />

21,0<br />

8,0<br />

7,0<br />

5,0<br />

23,6<br />

B B B<br />

A A A<br />

OPTIONAL<br />

BOTTOM PORTS<br />

C L<br />

C L<br />

C L<br />

5,5<br />

5,5<br />

3,18<br />

13,6<br />

7,14<br />

25,4<br />

FLOW CONTROL<br />

DIMENSIONS<br />

SPACING SIZE<br />

A<br />

STANDARD<br />

21.0<br />

PORT SIZE<br />

B<br />

C<br />

PER JB<br />

26.0<br />

1/8”<br />

20.0<br />

8.0<br />

GAGES<br />

40.0<br />

M5<br />

22.0<br />

6.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

non plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Single operator<br />

A B<br />

A<br />

B<br />

Double operator<br />

(Minimum DC wattage 5,4W)<br />

A<br />

A B<br />

B<br />

Valve w/o gage port<br />

Valve w/ gage port<br />

EXH IN<br />

45A-L00-DXXX-XXX<br />

45A-M00-DXXX-XXX<br />

EXH IN<br />

45A-N00-DXXX-XXX<br />

45A-P00-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

AA 120/60, 110/50<br />

A 18” (Flying leads)<br />

1 Non-locking Recessed<br />

KA Square connector<br />

AB 240/60, 220/50<br />

J Connector<br />

2 Locking Recessed<br />

KD Square connector<br />

with light<br />

AC 24/60, 24/50<br />

x Other Options<br />

x Other Options<br />

BA Flying leads<br />

FB 24VDC (1.8 W)<br />

xx Other Options<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (ORDER REGULATORS SEPARATELY) **<br />

EBM45A-xxxx-xx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder<br />

ports<br />

Bottom cylinder<br />

ports<br />

1/8” NPTF<br />

21 (w/o gage)<br />

EBM45A-003A-XX<br />

EBM45A-004A-XX<br />

# 10-32 UNF<br />

21 (w/o gage)<br />

EBM45A-003B-XX<br />

EBM45A-004B-XX<br />

1/8” NPTF<br />

40 (w/ gage)<br />

EBM45A-023A-XX<br />

EBM45A-024A-XX<br />

# 10-32 UNF<br />

40 (w/ gage)<br />

EBM45A-023B-XX<br />

EBM45A-024B-XX<br />

Number of stations (03=3 stations)<br />

** Other options available Consult factory.<br />

Note : clic for valves <strong>and</strong> regulators mounted to circuit bar at the factory (add - 9 to the model number).<br />

gage not supplied w/circuit bar.<br />

Pressure regulators :<br />

35A-00M (Adjusting knob)<br />

35A-00L (Slotted stem)<br />

35A-00U (Locking stem)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

VALVE BLANKING PLATE<br />

64,5<br />

21,0<br />

"A"<br />

21,0<br />

17,5<br />

33,0<br />

5,1 LOCKING RECESSED<br />

OPERATOR<br />

C L<br />

C L<br />

C L<br />

35,5<br />

B<br />

B<br />

A A A<br />

5,5<br />

B<br />

C<br />

B<br />

56,5<br />

28,0<br />

14,0<br />

IN<br />

EXH<br />

10,25<br />

Ø 5,2.<br />

2 MTG HOLES<br />

11,0<br />

5,0<br />

8,0<br />

35,5<br />

22,0<br />

5,0<br />

1/8” 2 PORTS<br />

BOTH ENDS<br />

14,5<br />

29,5<br />

40,0<br />

91,1<br />

16,0<br />

13,4<br />

SPACING SIZE<br />

STANDARD<br />

PER JB<br />

GAGES<br />

A<br />

21.0<br />

26.0<br />

40.0<br />

11,0<br />

5,5<br />

B<br />

B<br />

A<br />

A<br />

A<br />

C L<br />

C L<br />

21,0<br />

REGULATOR BLANKING<br />

PLATE<br />

15,5<br />

ADJ. LOCKING KNOB<br />

Port size<br />

B<br />

C<br />

B<br />

C L<br />

1/8”<br />

M5<br />

20.0<br />

22.0<br />

8.0<br />

6.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

non plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Single operator<br />

A B<br />

A<br />

B<br />

Double operator<br />

(Minimum DC wattage 5,4W)<br />

A<br />

A B<br />

B<br />

Valve w/o gage port<br />

Valve w/ gage port<br />

EXH IN<br />

45A-L00-DXXX-XXX<br />

45A-M00-DXXX-XXX<br />

EXH IN<br />

45A-N00-DXXX-XXX<br />

45A-P00-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

AA 120/60, 110/50<br />

A 18” (Flying leads)<br />

1 Non-locking Recessed<br />

KA Square connector<br />

AB 240/60, 220/50<br />

J Connector<br />

2 Locking Recessed<br />

KD Square connector<br />

with light<br />

AC 24/60, 24/50<br />

x Other Options<br />

x Other Options<br />

BA Flying leads<br />

FB 24VDC (1.8 W)<br />

xx Other Options<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

EBM45A-xxxx-xx<br />

HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS AND FLOW CONTROLS (ORDER REGULATOR AND FLOW CONTROL SEPARATELY) **<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder<br />

ports<br />

Bottom cylinder<br />

ports<br />

1/8” NPTF<br />

21 (w/o gage)<br />

EBM45A-007A-XX<br />

EBM45A-008A-XX<br />

# 10-32 UNF<br />

21 (w/o gage)<br />

EBM45A-007B-XX<br />

EBM45A-008B-XX<br />

1/8” NPTF<br />

40 (w/ gage)<br />

EBM45A-027A-XX<br />

EBM45A-028A-XX<br />

# 10-32 UNF<br />

40 (w/ gage)<br />

EBM45A-027B-XX<br />

EBM45A-028B-XX<br />

Number of stations (03=3 stations)<br />

** Other options available Consult factory.<br />

Note : clic for valves, regulators <strong>and</strong> flow controls mounted to circuit bar at the factory (add - 9 to the model number).<br />

gage not supplied w/circuit bar<br />

Pressure regulators <strong>and</strong> flow controls:<br />

45A-001 (Slotted stem)<br />

45A-002 (Adjusting knob)<br />

45A-003 (Locking stem)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

21.0<br />

CL<br />

A<br />

CL<br />

CL<br />

CL<br />

66.5<br />

38.0<br />

A<br />

+<br />

+<br />

B<br />

+<br />

+<br />

B A<br />

LC<br />

CL<br />

LC<br />

LC<br />

LC<br />

CL<br />

LC<br />

LC<br />

B<br />

95.6<br />

APPROX.<br />

A<br />

A<br />

A<br />

A<br />

EX<br />

45.0<br />

B<br />

B<br />

B<br />

B<br />

IN<br />

19.5<br />

34.5<br />

A A<br />

B B<br />

5.0 27.0<br />

8.0<br />

LC<br />

CL<br />

LC<br />

LC<br />

15.3<br />

19.0<br />

5.0<br />

A<br />

5.0<br />

15.5<br />

A 26.5<br />

28.5<br />

8.0<br />

B<br />

A<br />

15.5<br />

A<br />

A<br />

B<br />

1/8" - 27 N.P.T.F.<br />

1/8" - 28 B.S.P.PL.<br />

1/8" - 28 B.S.P.TR.<br />

#10-32 UNF<br />

M5 X 0.8<br />

Dim.<br />

SLOTTED<br />

LOCKING STEM<br />

ADJUSTING KNOB<br />

B<br />

6.0<br />

13.4<br />

Dim.<br />

STANDARD<br />

SPACING<br />

SPACING<br />

FOR GAUGES<br />

A<br />

21.0<br />

40.0<br />

26.5<br />

A<br />

Note: Bottom & side cylinder ports not available on the same station<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v plug-in<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />

Single operator<br />

A B<br />

A<br />

B<br />

Double operator<br />

(Minimum DC wattage 5,4W)<br />

A<br />

A B<br />

B<br />

EXH<br />

IN<br />

45A-L00-DXXJ-XFM<br />

EXH<br />

IN<br />

45A-N00-DXXJ-XFM<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR**<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

ECD45A-xxxx-xx-xx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

21<br />

ECD45A-001A-A0-XX<br />

ECD45A-002A-A0-XX<br />

# 10-32 UNF<br />

21<br />

ECD45A-001B-A0-XX<br />

ECD45A-002B-A0-XX<br />

1/8” NPTF<br />

30<br />

ECD45A-031A-C0-XX<br />

ECD45A-032A-C0-XX<br />

# 10-32 UNF<br />

30<br />

ECD45A-031B-C0-XX<br />

ECD45A-032B-C0-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

for multi-pin connector (9, 15 or 25).<br />

O P T I O N S<br />

ECD45A-002A-A0-XX<br />

- clic for double operator valve (replace by 8) (Bottom cylinder ports).<br />

** A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal w/light (120V)<br />

CB = terminal w/light (240V)<br />

CD = terminal w/light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

BLANKING STATION KIT<br />

OPTIONAL PRESSURE<br />

SENSING PORT<br />

21,0<br />

30,0 30,0 21,0<br />

21,0<br />

26,8<br />

73,8<br />

5,1 LOCKING RECESSED<br />

OPERATOR<br />

C L<br />

C L<br />

C L<br />

C L<br />

47,5<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

28,5<br />

68,5<br />

19,8<br />

EX<br />

IN<br />

17,0<br />

40,0<br />

20,0<br />

11,0<br />

37,7<br />

34,5<br />

18,3<br />

6,0<br />

10,0<br />

4,5<br />

Ø 5,2 MOUNTING HOLES<br />

1,45<br />

1/8”<br />

INLET & EXHAUST<br />

PORTS EACH END<br />

13,5<br />

29,0<br />

57,3<br />

78,0<br />

84,8<br />

1” NPSM<br />

CONDUIT<br />

EACH END<br />

5,5<br />

5,5<br />

1,8<br />

4,5<br />

8,0<br />

7,8<br />

68,5<br />

40,0<br />

105,58<br />

17,0 19,0<br />

4,5<br />

29,0<br />

57,3<br />

13,5<br />

37,0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

plug-in<br />

with side<br />

Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR "PLUG-IN" CIRCUIT BAR<br />

Single operator<br />

A<br />

A<br />

B<br />

B<br />

EXH IN<br />

45A-L00-DXXJ-XFM<br />

45A-M00-DXXJ-XFM<br />

Valve w/o gage port<br />

Valve w/ gage port<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY) **<br />

ECD45A-xxxx-xx-xx<br />

Port size<br />

1/8” NPTF<br />

# 10-32 UNF<br />

1/8” NPTF<br />

# 10-32 UNF<br />

1/8” NPTF<br />

# 10-32 UNF<br />

Spacing<br />

mm<br />

21<br />

21<br />

30<br />

30<br />

40<br />

40<br />

Bottom cylinder ports<br />

ECD45A-004A-A0-XX<br />

ECD45A-004B-A0-XX<br />

ECD45A-034A-C0-XX<br />

ECD45A-034B-C0-XX<br />

ECD45A-024A-A0-XX<br />

ECD45A-024B-A0-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves <strong>and</strong> regulators mounted to circuit bar at the factory (add - 9 to<br />

the model number).<br />

for multi-pin connector (9, 15 or 25).<br />

minimum spacing for terminal strips is 30 mm.<br />

use 40 mm spacing for gages.<br />

** Pressure Regulators :<br />

35A-00M (Adjusting knob)<br />

35A-00L (Slotted stem)<br />

35A-00U (Locking stem)<br />

Consult “Precautions”before use, installation or service of MAC Valves.<br />

** A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal w/light (120V)<br />

CB = terminal w/light (240V)<br />

CD = terminal w/light (24V)


B<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

BLANKING STATION KIT<br />

21,0<br />

30,0 30,0 21,0<br />

21,0<br />

26,8<br />

OPTIONAL PRESSURE<br />

SENSING PORT<br />

73,8<br />

0,2 LOCKING RECESSED<br />

OPERATOR<br />

C L<br />

C L<br />

C L<br />

C L<br />

47,5<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

28,5<br />

68,5<br />

19,8<br />

EX<br />

IN<br />

17,0<br />

40,0<br />

20,0<br />

11,0<br />

6,0<br />

10,0<br />

4,5<br />

Ø 5,2 MOUNTING HOLES<br />

1,45<br />

1/8” INLET &<br />

EXHAUST PORTS<br />

EACH END<br />

13,5<br />

29,0<br />

57,3<br />

78,0<br />

84,8<br />

1” NPSM<br />

CONDUIT<br />

EACH END<br />

15,5<br />

4,5<br />

A<br />

5,5<br />

5,5<br />

LOCK<br />

ADJ. LOCKING KNOB<br />

60,5 20,7<br />

34,5<br />

37,0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

plug-in<br />

with s<strong>and</strong>wich<br />

Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />

Single operator<br />

A<br />

A<br />

B<br />

B<br />

EXH IN<br />

45A-L00-DXXJ-XFM<br />

45A-M00-DXXJ-XFM<br />

Valve w/o gage port<br />

Valve w/ gage port<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

ECD45A-xxxx-xx-xx<br />

HOW TO ORDER "PLUG-IN" CIRCUIT BAR WITH SANDWICH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY) **<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

21<br />

ECD45A-001A-A0-XX<br />

ECD45A-002A-A0-XX<br />

# 10-32 UNF<br />

21<br />

ECD45A-001B-A0-XX<br />

ECD45A-002B-A0-XX<br />

1/8” NPTF<br />

30<br />

ECD45A-031A-C0-XX<br />

ECD45A-032A-C0-XX<br />

# 10-32 UNF<br />

30<br />

ECD45A-031B-C0-XX<br />

ECD45A-032B-C0-XX<br />

1/8” NPTF<br />

40<br />

ECD45A-021A-A0-XX<br />

ECD45A-022A-A0-XX<br />

# 10-32 UNF<br />

40<br />

ECD45A-021B-A0-XX<br />

ECD45A-022B-A0-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves <strong>and</strong> regulators mounted to circuit bar at the factory, add - 9 to<br />

the model number.<br />

for multi-pin connector (9, 15 or 25).<br />

minimum spacing for terminal strips is 30 mm.<br />

use 40 mm spacing for gages.<br />

** Pressure Regulators :<br />

PR45A-AA0A (Adjusting knob)<br />

PR45A-AB0A (Slotted stem)<br />

PR45A-AC0A (Locking stem)<br />

Consult “Precautions”before use, installation or service of MAC Valves.<br />

** A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal w/light (120V)<br />

CB = terminal w/light (240V)<br />

CD = terminal w/light (24V)


L<br />

OCK<br />

L OCK<br />

L OCK<br />

L OCK<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

26.0<br />

15.0<br />

A<br />

A<br />

Dim.<br />

A<br />

Dim.<br />

B<br />

28.5<br />

40.0<br />

10.0<br />

B A B A B A B A<br />

1/8" - 27 N.P.T.F.<br />

1/8" - 28 B.S.P.PL.<br />

1/8" - 28 B.S.P.TR.<br />

#10-32<br />

M5 0.8<br />

STANDARD<br />

SPACING<br />

OPTIONAL<br />

SPACING<br />

SPACING<br />

FOR GAUGES<br />

21.0<br />

30.0<br />

40.0<br />

SLOTTED<br />

LOCKING STEM<br />

ADJUSTING KNOB<br />

Note: Bottom & side cylinder ports not available on the same station<br />

6.0<br />

13.4<br />

21.0<br />

A<br />

94.0<br />

APPROX.<br />

B<br />

B<br />

B<br />

B<br />

B<br />

EX<br />

123.1<br />

APPROX.<br />

37.7<br />

26.5<br />

15.5<br />

4.5<br />

TYP.<br />

20.8<br />

B<br />

A<br />

B<br />

78.0<br />

A<br />

A<br />

A<br />

A<br />

IN<br />

49.0<br />

64.5<br />

34.5 A<br />

A<br />

20.7<br />

96.0<br />

17.0<br />

19.8<br />

20.0<br />

A<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

plug-in<br />

with F. C.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />

Port size<br />

(see base)<br />

Single operator<br />

A<br />

A<br />

B<br />

B<br />

Valve less base<br />

EXH<br />

IN<br />

45A-L00-DXXJ-XFM<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER "PLUG-IN" CIRCUIT BAR WITH FLOW CONTROLS **<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

ECD45A-xxxx-xx-xx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

21<br />

--------<br />

ECD45A-006A-A0-XX<br />

# 10-32 UNF<br />

21<br />

--------<br />

ECD45A-006B-A0-XX<br />

1/8” NPTF<br />

30<br />

ECD45A-035A-A0-XX<br />

--------<br />

# 10-32 UNF<br />

30<br />

ECD45A-035B-A0-XX<br />

--------<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

for multi-pin connector (9, 15 or 25).<br />

minimum spacing for terminal strips is 30 mm.<br />

** A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal w/light (120V)<br />

CB = terminal w/light (240V)<br />

CD = terminal w/light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

L<br />

68.6<br />

40.0<br />

19.8<br />

17.0<br />

13.2<br />

Max.<br />

78.0<br />

84.3<br />

89.2 ( Optional )<br />

29.0<br />

13.5<br />

EX IN<br />

1/8 (IN + EX)<br />

43.0<br />

40.0<br />

14.5<br />

13.0<br />

8.0<br />

A<br />

B A B A B A B<br />

10.3<br />

DIA. 5.2 (2X)<br />

37.0<br />

37.0<br />

26.0<br />

21.0<br />

51.0<br />

4.5<br />

Number of<br />

stations<br />

2<br />

3<br />

4<br />

5<br />

6<br />

4.5<br />

7<br />

8<br />

9<br />

10<br />

DIM. L<br />

77.0<br />

107.0<br />

137.0<br />

167.0<br />

197.0<br />

227.0<br />

257.0<br />

287.0<br />

317.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

plug-in<br />

with Pr. Reg.<br />

<strong>and</strong> F. C.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />

Port size<br />

(see base)<br />

Single operator<br />

A<br />

A<br />

B<br />

B<br />

Valve less base (w/o gage port)<br />

Valve less base (w/ gage port)<br />

EXH IN<br />

45A-L00-DXXJ-XFM<br />

45A-M00-DXXJ-XFM<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

ECD45A-xxxx-xx-xx<br />

HOW TO ORDER "PLUG-IN" CIRCUIT BAR WITH REGULATORS AND FLOW CONTROLS (TO BE ORDERED SEPARATELY) **<br />

Port size<br />

1/8” NPTF<br />

# 10-32 UNF<br />

1/8” NPTF<br />

# 10-32 UNF<br />

Spacing<br />

mm<br />

21<br />

21<br />

30<br />

30<br />

Bottom cylinder ports<br />

ECD45A-007A-A0-XX<br />

ECD45A-007B-A0-XX<br />

ECD45A-037A-C0-XX<br />

ECD45A-037B-C0-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves <strong>and</strong> regulators mounted to circuit bar at the factory<br />

(add - 9 to the model number).<br />

for multi-pin connector (9, 15 or 25).<br />

minimum spacing for terminal strips is 30 mm.<br />

Pressure regulators <strong>and</strong> flow controls:<br />

45A-001 (Slotted stem)<br />

45A-002 (Adjusting knob)<br />

45A-003 (Locking stem)<br />

** A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

** C0 = terminal strip<br />

CA = terminal w/light (120V)<br />

CB = terminal w/light (240V)<br />

CD = terminal w/light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

L<br />

68.6<br />

40.0<br />

19.8<br />

17.0<br />

10.0<br />

21.0<br />

78.0<br />

84.3<br />

89.2 ( Optional )<br />

29.0<br />

13.5<br />

IN<br />

EX<br />

1/8 (IN + EX)<br />

7.0<br />

37.0<br />

A<br />

A<br />

A<br />

A<br />

B B B B<br />

DIA. 5.2 (2<br />

20.7<br />

34.5<br />

37.0<br />

148.2<br />

4.5<br />

4.5<br />

20.5<br />

17.3<br />

26.0<br />

21.0<br />

42.0<br />

Number of<br />

stations<br />

DIM. L<br />

2<br />

68.0<br />

3<br />

89.0<br />

4<br />

110.0<br />

5<br />

131.0<br />

6<br />

152.0<br />

7<br />

173.0<br />

8<br />

194.0<br />

9<br />

215.0<br />

10<br />

236.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting s<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

plug-in<br />

with integral<br />

terminal strip<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-LOO-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />

Single operator<br />

A<br />

A<br />

B<br />

B<br />

EXH<br />

IN<br />

45A-L00-DXXJ-XFM<br />

Valve less base<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR**<br />

ECE45A-011A-CD-02<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

26<br />

ECE45A-011A-C0-XX<br />

ECE45A-012A-C0-XX<br />

# 10-32 UNF<br />

26<br />

ECE45A-011B-C0-XX<br />

ECE45A-012B-C0-XX<br />

Number of stations (03=3 stations)<br />

End plate kit required : M-45017<br />

Note : clic for valves mounted on circuit bar at the factory (add - 9 to the<br />

model number).<br />

2<br />

** C0 = terminal strip<br />

CA = terminal strip w/light (120V)<br />

CB = terminal strip w/light (240V)<br />

CD = terminal strip w/light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

49.5<br />

38.5<br />

A<br />

A<br />

10.0<br />

28.5<br />

40.0<br />

LC<br />

C L C L C L<br />

1/4" - 18 N.P.T.F.<br />

TYP. (2) EACH END<br />

68.4<br />

C L<br />

C L<br />

C L<br />

C L<br />

IN<br />

EX<br />

B<br />

B<br />

B<br />

B<br />

EX<br />

IN<br />

89.4<br />

100.4<br />

A<br />

A<br />

A<br />

A<br />

G<br />

33.9<br />

71.4<br />

79.7<br />

65.9<br />

58.4<br />

16.0<br />

44.5<br />

26.0<br />

1" - 11 1/2 N.P.S.M<br />

19.9<br />

28.9<br />

10.9<br />

158.0<br />

A 39.0<br />

A 50.0<br />

4.5<br />

TYP.<br />

Note: Bottom & side cylinder ports not available on the same station<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

integral terminal<br />

strip <strong>and</strong><br />

plug-in with<br />

side Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />

Single operator<br />

A<br />

A<br />

B<br />

B<br />

EXH IN<br />

45A-L00-DXXJ-XFM<br />

45A-M00-DXXJ-XFM<br />

Valve less base w/o gage port<br />

Valve less base w/ gage port<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY) **<br />

ECE45A-xxxx-xx-xx<br />

Port size<br />

1/8” NPTF<br />

# 10-32 UNF<br />

1/8” NPTF<br />

# 10-32 UNF<br />

Spacing<br />

mm<br />

26<br />

26<br />

40<br />

40<br />

Bottom cylinder ports<br />

ECE45A-014A-C0-XX<br />

ECE45A-014B-C0-XX<br />

ECE45A-024A-C0-XX<br />

ECE45A-024B-C0-XX<br />

Number of stations (03=3 stations)<br />

End plate kit required : M-45017<br />

Note : clic for valves <strong>and</strong> regulators mounted to circuit<br />

bar at the factory (add - 9 to the model number).<br />

Use 40 mm spacing for valves w/ gage port.<br />

** Pressure Regulators :<br />

35A-00M (Adjusting knob)<br />

35A-00L (Slotted stem)<br />

35A-00U (Locking stem)<br />

** C0 = terminal strip<br />

CA = terminal strip w/light (120V)<br />

CB = terminal strip w/light (240V)<br />

CD = terminal strip w/light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

40.0<br />

LC<br />

LC<br />

LC<br />

68.4<br />

1/4" - 18 N.P.T.F.<br />

TYP. (2) EACH END<br />

B<br />

154.5<br />

89.4<br />

100.4<br />

71.4<br />

33.9<br />

58.4<br />

16.0<br />

44.5<br />

A<br />

C L C L C L C L C L C L C L C L<br />

4.5<br />

B<br />

B<br />

B<br />

B<br />

EX<br />

IN<br />

EX<br />

A<br />

A<br />

A<br />

A<br />

IN<br />

C L<br />

79.7<br />

65.9<br />

G<br />

1" - 11 1/2 N.P.S.M<br />

19.9<br />

28.9<br />

10.9<br />

158.0<br />

A<br />

A<br />

39.0<br />

50.0<br />

Dim.<br />

B<br />

Dim.<br />

A<br />

SLOTTED<br />

LOCKING STEM<br />

ADJUSTING KNOB<br />

6.0<br />

13.4<br />

STANDARD<br />

SPACING<br />

SPACING<br />

FOR GAUGES<br />

26.0<br />

40.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

integral terminal<br />

strip <strong>and</strong><br />

plug-in with<br />

s<strong>and</strong>wich Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />

Single operator<br />

A<br />

A<br />

B<br />

B<br />

EXH IN<br />

45A-L00-DXXJ-XFM<br />

45A-M00-DXXJ-XFM<br />

Valve w/o gage port<br />

Valve w/ gage port<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR WITH SANDWICH REGULATORS (TO BE ORDERED SEPARATELY) **<br />

ECE45A-xxxx-xx-xx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

26<br />

ECE45A-011A-C0-XX<br />

ECE45A-012A-C0-XX<br />

# 10-32 UNF<br />

26<br />

ECE45A-011B-C0-XX<br />

ECE45A-012B-C0-XX<br />

1/8” NPTF<br />

40<br />

ECE45A-021A-C0-XX<br />

ECE45A-022A-C0-XX<br />

# 10-32 UNF<br />

40<br />

ECE45A-021B-C0-XX<br />

ECE45A-022B-C0-XX<br />

Number of stations (03=3 stations)<br />

End plate kit required : M-45017<br />

Note : clic for valves <strong>and</strong> regulators mounted to circuit<br />

bar at the factory (add - 9 to the model number).<br />

Use 40 mm spacing for valves w/ gage port.<br />

** Pressure Regulators :<br />

PR45A-AA0A (Adjusting knob)<br />

PR45A-AB0A (Slotted stem)<br />

PR45A-AC0A (Locking stem)<br />

** C0 = terminal strip<br />

CA = terminal strip w/light (120V)<br />

CB = terminal strip w/light (240V)<br />

CD = terminal strip w/light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


L OCK<br />

LOCK<br />

LOCK<br />

L<br />

OCK<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

10.0<br />

49.5<br />

38.5<br />

A<br />

A<br />

Dim.<br />

A<br />

Dim.<br />

B<br />

28.5<br />

40.0<br />

1/8" - 27 N.P.T.F.<br />

1/8" - 28 B.S.P.PL.<br />

1/8" - 28 B.S.P.TR.<br />

#10-32<br />

M5 X 0.8<br />

STANDARD<br />

SPACING<br />

SPACING FOR<br />

GAUGES<br />

26.0<br />

40.0<br />

SLOTTED<br />

LOCKING STEM<br />

ADJUSTING KNOB<br />

Note: Bottom & side cylinder ports not available on the same station<br />

6.0<br />

13.4<br />

LC<br />

LC<br />

LC<br />

LC<br />

93.8<br />

1/4" - 18 N.P.T.F.<br />

TYP. (2) EACH END<br />

LC<br />

LC<br />

LC<br />

LC<br />

B<br />

144.5<br />

APPROX.<br />

IN<br />

EX<br />

B<br />

B<br />

B<br />

B<br />

EX<br />

IN<br />

89.4<br />

A<br />

A<br />

A<br />

A<br />

G<br />

33.9<br />

71.4<br />

79.7<br />

65.9<br />

58.4<br />

16.0<br />

44.5<br />

A<br />

1" - 11 1/2 N.P.S.M<br />

19.9<br />

28.9<br />

10.9<br />

A<br />

A<br />

39.0<br />

50.0<br />

4.5<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

plug-in with<br />

integral terminal<br />

strip with F. C.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />

Single operator<br />

A<br />

A<br />

B<br />

B<br />

EXH<br />

IN<br />

45A-L00-DXXJ-XFM<br />

Valve less base<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR WITH FLOW CONTROLS **<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

ECE45A-xxxx-xx-xx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

26<br />

--------<br />

ECE45A-016A-C0-XX<br />

# 10-32 UNF<br />

26<br />

--------<br />

ECE45A-016B-C0-XX<br />

1/8” NPTF<br />

30<br />

ECE45A-035A-C0-XX<br />

--------<br />

# 10-32 UNF<br />

30<br />

ECE45A-035B-C0-XX<br />

--------<br />

Number of stations (03=3 stations)<br />

End plate kit required : M-45017<br />

Note : clic for valves <strong>and</strong> regulators mounted to circuit<br />

bar at the factory (add - 9 to the model number).<br />

** C0 = terminal strip<br />

CA = terminal strip w/light (120V)<br />

CB = terminal strip w/light (240V)<br />

CD = terminal strip w/light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

27.5<br />

13.0<br />

8.0 10.3<br />

40.0<br />

B A<br />

B A<br />

B A<br />

B A<br />

+<br />

LC<br />

+<br />

+<br />

+ + + + +<br />

C L C L C L<br />

1/8" - 27 N.P.T.F.<br />

1/8" - 28 B.S.P.PL.<br />

1/8" - 28 B.S.P.TR.<br />

#10-32<br />

M5 X 0.8<br />

1/4" - 18 N.P.T.F.<br />

TYP. (2) EACH END<br />

68.4<br />

B<br />

B<br />

B<br />

B<br />

IN<br />

EX<br />

EX<br />

111.9<br />

IN<br />

89.4<br />

A<br />

A<br />

A<br />

A<br />

71.4<br />

65.9<br />

79.7<br />

G<br />

33.9<br />

58.4<br />

16.0<br />

44.5<br />

A<br />

1" - 11 1/2 N.P.S.M 10.9<br />

158.0<br />

19.9<br />

28.9<br />

A<br />

A<br />

39.0<br />

50.0<br />

4.5<br />

Dim.<br />

STANDARD<br />

SPACING<br />

OPTIONAL<br />

SPACING<br />

A<br />

26.0<br />

30.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.<br />

Note: Bottom & side cylinder ports not available on the same station


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 45<br />

Function Port size Flow (Max) Circuit bar mounting<br />

4/2 1/8” NPTF - #10-32 UNF 0.10C v<br />

integral terminal<br />

strip with<br />

plug-in with<br />

Pr. Reg. <strong>and</strong> F. C.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Burn-out proof solenoid on AC service.<br />

Reset<br />

HOW TO ORDER<br />

45A-xxx-DxxJ-xFM<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING “PLUG-IN”<br />

Single operator<br />

A<br />

A<br />

B<br />

B<br />

EXH IN<br />

45A-L00-DXXJ-XFM<br />

45A-M00-DXXJ-XFM<br />

Valve less base<br />

Valve less base w/ gage port<br />

SOLENOID OPERATOR ➤<br />

D XX J- X FM *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

AA 120/60, 110/50<br />

AB 240/60, 220/50<br />

AC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

1 Non-locking Recessed<br />

2 Locking Recessed<br />

x Other Options<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR WITH PRESSURE AND FLOW CONTROLS (TO BE ORDERED SEPARATELY) **<br />

ECE45A-xxxx-xx-xx<br />

Port size<br />

1/8” NPTF<br />

# 10-32 UNF<br />

1/8” NPTF<br />

# 10-32 UNF<br />

Spacing<br />

mm<br />

26<br />

26<br />

40<br />

40<br />

Bottom cylinder ports<br />

ECE45A-017A-C0-XX<br />

ECE45A-017B-C0-XX<br />

ECE45A-027A-C0-XX<br />

ECE45A-027B-C0-XX<br />

Number of stations (03=3 stations)<br />

End plate kit required : M-45017<br />

Note : clic for valves <strong>and</strong> regulators mounted to circuit<br />

bar at the factory (add - 9 to the model number).<br />

Use 40 mm spacing for valves w/ gage port.<br />

** Pressure Regulators :<br />

45A-001 (Slotted stem)<br />

45A-002 (Adjusting knob)<br />

45A-003 (Locking stem)<br />

** C0 = terminal strip<br />

CA = terminal strip w/light (120V)<br />

CB = terminal strip w/light (240V)<br />

CD = terminal strip w/light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


L O<br />

CK<br />

L<br />

OCK<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 45<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

2 mm<br />

1.8 W : 0.08 C v , 5.4 W : 0.1 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

Nema 4<br />

120 VAC/60 = Inrush : 10.9 VA (0.09 AMPS) Holding : 7. 7VA (0.06 AMPS)<br />

DC VOLTS = 1.8 W to 12.7 W<br />

24 VDC (5.4W) Energize : 6 ms De-energize : 2 ms<br />

120 VAC Energize : 3-8 ms De-energize : 2-7 ms<br />

Spare parts :<br />

Options :<br />

• Solenoid operator (power 5.4 W) : DXXJ-XFM, including mounting screws 35013.<br />

• Seal between solenoid <strong>and</strong> valve body : 16402. • Seal between base <strong>and</strong> valve : 16453.<br />

• Valve mounting screw (x2) : 35020. • Blanking plate valve : M-45010. • Blanking plate regulator : M-35005.<br />

• BSPP threads. • High flow up to 0.14C v , according to wattage. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

EX<br />

B<br />

B<br />

B<br />

B<br />

B<br />

A<br />

B A<br />

B A<br />

B A<br />

L O<br />

CK<br />

L O<br />

CK<br />

Dim.<br />

B<br />

Dim.<br />

A<br />

40.0<br />

SLOTTED<br />

LOCKING STEM<br />

ADJUSTING KNOB<br />

6.0<br />

13.4<br />

STANDARD<br />

SPACING<br />

SPACING<br />

FOR GAUGES<br />

26.0<br />

40.0<br />

+<br />

+<br />

+<br />

+<br />

+<br />

+<br />

+<br />

+<br />

LC<br />

C L C L C L<br />

LC<br />

LC<br />

LC<br />

LC<br />

1/4" - 18 N.P.T.F.<br />

TYP. (2) EACH END<br />

68.4<br />

B<br />

LC<br />

LC<br />

LC<br />

LC<br />

154.5<br />

IN<br />

EX<br />

IN<br />

89.4<br />

A<br />

A<br />

A<br />

A<br />

71.4<br />

65.9<br />

79.7<br />

G<br />

33.9<br />

58.4<br />

16.0<br />

44.5<br />

A<br />

1" - 11 1/2 N.P.S.M<br />

19.9<br />

28.9<br />

10.9<br />

158.0<br />

A<br />

A<br />

39.0<br />

50.0<br />

4.5<br />

TYP.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Section 2 Options<br />

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Codification table for voltages / Wire length / Manual operators / Electrical connections<br />

VALVE CODE ➤<br />

- D XX X - X XX<br />

1 2 3 4<br />

OPTIONS AVAILABLE FOR<br />

- Solenoid valves 35 & 45 Series<br />

Consult “Precautions”before use, installation or service of MAC Valves.


OPTIONS<br />

Back<br />

1. VOLTAGE<br />

- D XX X - X XX VOLTAGE<br />

AD 24/60<br />

AE 200/60<br />

AF 240/50<br />

AG 100/50, 100/60, 110/60<br />

DB 12 VDC (5.4 W)<br />

DC 12 VDC (7.5 W)<br />

DD 24 VDC (7.3 W)<br />

DE<br />

12 VDC (12.7 W) CLSF<br />

DK 110 VDC (5.8 W)<br />

DL 64 VDC (6.0 W)<br />

DM 36 VDC (5.8 W)<br />

DN 6 VDC (6.0 W)<br />

DP 48 VDC (5.8 W)<br />

DU 24 VDC (6.0 W)<br />

EA 12 VDC (6.0 W)<br />

FA 12 VDC (1.8 W)<br />

FE 12 VDC (2.4 W)<br />

FF 24 VDC (2.4 W)<br />

2. WIRE LENGTH<br />

- D XX X - X XX WIRE LENGTH<br />

B 24”<br />

C 36”<br />

D 48”<br />

E 72”<br />

F 96”<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Back<br />

3. MANUAL OPERATOR<br />

- D XX X - X XX MANUAL OPERATOR<br />

0 No operator<br />

1 Non-locking recessed<br />

2 Locking recessed<br />

3 Non-locking extended<br />

4 Locking extended<br />

4. ELECTRICAL CONNECTION<br />

- D XX X - X XX ELECTRICAL CONNECTION<br />

BA Flying leads<br />

BK BA with protection diode<br />

BL BA with protection varistor<br />

CA 1/2" NPS conduit<br />

*FN Plug-in with diode<br />

*FP Plug-in with M.O.V.<br />

JB Rectangular connector<br />

JD Rectangular connector with light<br />

JM Rectangular connector, male only<br />

KA Square connector<br />

KB Square connector with protection diode<br />

KC Square connector with protection varistor<br />

KD Square connector with light<br />

KE Square connector with light <strong>and</strong> protection diode<br />

KF Square connector with light <strong>and</strong> protection varistor<br />

KJ Square connector (male only)<br />

KK Square connector with protection diode (male only)<br />

KL Square connector with protection varistor (male only)<br />

TA Dual tabs<br />

TB TA with protection diode<br />

TD TA with light<br />

TE TA with light <strong>and</strong> protection diode<br />

TJ Dual tabs (male only)<br />

TK TJ with protection diode<br />

TM TJ with light<br />

TN TJ with light <strong>and</strong> protection diode<br />

* For use with the ECD <strong>and</strong> ECE style circuit bars.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

PIN #6<br />

PIN #9<br />

MOD. SD09<br />

PIN #1<br />

PIN #5<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 9<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 7 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 2 common wires<br />

PIN #9<br />

PIN #15<br />

MOD. SD15<br />

PIN #1<br />

PIN #8<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 15<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 12 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 3 common wires<br />

PIN #14<br />

PIN #25<br />

MOD. SD25<br />

PIN #1<br />

PIN #13<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 25<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 20 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 5 common wires<br />

Note : Use desired MOD. number after circuit bar part number


O p t i o n s<br />

OPTIONS<br />

Connector termination details<br />

CONNECTOR<br />

SOL 1<br />

SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />

Single solenoid circuit bar<br />

SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />

CONNECTOR<br />

SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />

Double solenoid circuit bar<br />

SD09 SD15 SD25<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

8<br />

COMMON (+)<br />

13<br />

COMMON (+)<br />

21<br />

COMMON (+)<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

9<br />

COMMON (+)<br />

8<br />

SOL. 8<br />

8<br />

SOL. 8<br />

14<br />

COMMON (+)<br />

22<br />

COMMON (+)<br />

9<br />

SOL. 9<br />

9<br />

SOL. 9<br />

10 SOL. 10<br />

10 SOL. 10<br />

11<br />

SOL. 11<br />

11<br />

SOL. 11<br />

12 SOL. 12<br />

12 SOL. 12<br />

15<br />

COMMON (+)<br />

23<br />

COMMON (+)<br />

13<br />

SOL. 13<br />

14 SOL. 14<br />

15<br />

SOL. 15<br />

16 SOL. 16<br />

24<br />

COMMON (+)<br />

17<br />

18 SOL. 18<br />

19<br />

20 SOL. 20<br />

SOL. 17<br />

SOL. 19<br />

25<br />

COMMON (+)


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Circuit bar mounting<br />

non plug-in<br />

cyl. ports in<br />

valve with<br />

opt. F. C.<br />

non plug-in<br />

cyl. ports in<br />

base with<br />

opt. F. C.<br />

add-on style<br />

non plug-in cyl.<br />

ports in valve<br />

with opt. F. C.<br />

add-on style<br />

non plug-in cyl.<br />

ports in base<br />

with opt. F. C.<br />

non plug-in<br />

cyl. ports in<br />

valve with<br />

opt. Pr. Reg.<br />

non plug-in<br />

cyl. ports<br />

in base<br />

non plug-in<br />

cyl. ports in<br />

base with<br />

Pr. Reg.<br />

add-on style<br />

non plug-in<br />

cyl. ports in<br />

base<br />

add-on style<br />

non plug-in cyl.<br />

ports in base<br />

with Pr. Reg.<br />

plug-in<br />

plug-in<br />

with Pr. Reg.<br />

add-on style<br />

plug-in<br />

add-on style<br />

plug-in<br />

with Pr. Reg.<br />

plug-in<br />

add-a-unit<br />

stations<br />

plug-in<br />

add-a-unit<br />

stations<br />

with Pr. Reg.<br />

Manual operator<br />

Armature<br />

Coil<br />

Push pin<br />

Pole piece<br />

“D” seal<br />

Conical seat<br />

Poppet<br />

4<br />

2<br />

5<br />

1<br />

Valve return spring<br />

3<br />

SERIES FEATURES<br />

• Short stroke solenoid produces high energization shifting force.<br />

• High force return spring due to high force solenoid maximizes<br />

both energization <strong>and</strong> de-energization shifting forces.<br />

• Built-in wear compensation - valve stroke is shorter than solenoid stroke.<br />

• Four (4) bonded balanced poppets on a one-piece valve stem.<br />

• End poppets seal first on conical seats <strong>and</strong> cushion inlet poppet, eliminating cutting.<br />

• Exhaust seals are not under inlet pressure thus reducing friction.<br />

• Short stroking balanced poppet allows for direct solenoid operation with high shifting forces,<br />

minimized friction, fast response <strong>and</strong> high flow in a small package.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting Profile<br />

non plug-in<br />

5/2 3/8” 0.5C v<br />

cyl. ports in<br />

valve with<br />

29 mm<br />

opt. F. C.<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Valve port size<br />

Valve less base<br />

2<br />

4<br />

12<br />

14<br />

1/8” NPTF<br />

1/4” NPTF<br />

3 1 5<br />

47A-MG0-HXXX-XXX<br />

47A-MH0-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

A 18”<br />

1 Non-locking<br />

BA<br />

Flying leads<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

BC<br />

Flying leads with light<br />

DC 24VDC (1.8 W)<br />

x<br />

Other Options<br />

MA<br />

MC<br />

Plug-in wire assy<br />

Plug-in wire assy<br />

DD 24VDC (1.0 W)<br />

with light<br />

AA<br />

120VAC (must use with<br />

HA<br />

Plug-in connector with<br />

rectified connector)<br />

rectifier <strong>and</strong> light<br />

xx<br />

Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

COMMON INLET & EXHAUST<br />

3/8” NPTF<br />

Without flow controls<br />

(20 mm)<br />

EBM47A-01CAK-XX<br />

EBM47A-xxxxx-xx<br />

With flow controls<br />

(20 mm)<br />

EBM47A-01DAK-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


4<br />

4<br />

4<br />

4<br />

2<br />

2<br />

2<br />

2<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47002.<br />

• Flow control kit (x2) : N-37001.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

78.1<br />

25.0 20.0<br />

7.0<br />

96.0<br />

TYP.<br />

14.5<br />

132.4<br />

31.1<br />

50.6<br />

3 1 5<br />

12<br />

12<br />

12<br />

12<br />

3<br />

1<br />

5<br />

82.0<br />

26.5<br />

26.5<br />

27.8<br />

26.5<br />

14<br />

14<br />

14<br />

14<br />

29.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

5/2 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

non plug-in<br />

cyl. ports in<br />

base with<br />

opt. F. C.<br />

29 mm<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

Valve<br />

(see base)<br />

2<br />

4<br />

12<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

A 18”<br />

1 Non-locking<br />

BA<br />

Flying leads<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

BC<br />

Flying leads with light<br />

DC 24VDC (1.8 W)<br />

x<br />

Other Options<br />

MA<br />

MC<br />

Plug-in wire assy<br />

Plug-in wire assy<br />

DD 24VDC (1.0 W)<br />

with light<br />

AA<br />

120VAC (must use with<br />

HA<br />

Plug-in connector with<br />

rectified connector)<br />

rectifier <strong>and</strong> light<br />

xx<br />

Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

1/8” NPTF<br />

1/4” NPTF<br />

6 mm tube receptacle<br />

Bottom cylinder ports<br />

(18 mm)<br />

EBM47A-00AAA-XX<br />

EBM47A-00AAB-XX<br />

EBM47A-00AAG-XX<br />

EBM47A-xxxxx-xx<br />

Bottom cylinder ports with flow controls<br />

(18 mm)<br />

EBM47A-00BAA-XX<br />

EBM47A-00BAB-XX<br />

EBM47A-00BAG-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• Flow control kit (x2) : N-37001.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

104.0<br />

14.5<br />

78.1<br />

7.0<br />

90.0<br />

25.0 18.0<br />

132.4<br />

3 1 5<br />

12<br />

14<br />

12<br />

14<br />

12<br />

14<br />

12<br />

14<br />

3<br />

1<br />

5<br />

82.0<br />

26.5<br />

26.5<br />

27.8<br />

26.5<br />

2<br />

4 4<br />

2<br />

22.0<br />

30.0<br />

29.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting Profile<br />

add-on style<br />

5/2 3/8” 0.5C v<br />

non plug-in cyl.<br />

ports in valve<br />

35 mm<br />

with opt. F. C.<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Valve port size<br />

Valve<br />

2<br />

4<br />

12<br />

14<br />

1/8” NPTF<br />

1/4” NPTF<br />

3 1 5<br />

47A-MG0-HXXX-XXX<br />

47A-MH0-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

A 18”<br />

1 Non-locking<br />

BA<br />

Flying leads<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

BC<br />

Flying leads with light<br />

DC 24VDC (1.8 W)<br />

x<br />

Other Options<br />

MA<br />

MC<br />

Plug-in wire assy<br />

Plug-in wire assy<br />

DD 24VDC (1.0 W)<br />

with light<br />

AA<br />

120VAC (must use with<br />

HA<br />

Plug-in connector with<br />

rectified connector)<br />

rectifier <strong>and</strong> light<br />

xx<br />

Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

EBM47A-xxxxx-xx<br />

Port size<br />

COMMON INLET & EXHAUST<br />

3/8” NPTF<br />

Without flow controls<br />

(20 mm)<br />

EBM47A-01GBK-XX<br />

With flow controls<br />

(20 mm)<br />

EBM47A-01HBK-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

add-a-unit stations may be added to above bars.<br />

Maximum length for add-a-unit is 4 stations.<br />

O P T I O N S<br />

EBM47A-01GBK-XX<br />

- clic replace with “C” for add-a-unit.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


4<br />

4<br />

4<br />

4<br />

2<br />

2<br />

2<br />

2<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47002.<br />

• Flow control kit (x2) : N-37001. End plate kit : M-47004-01.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

57.0 XX<br />

25.0 20.0<br />

3/8" - 18 N.P.T.F.<br />

3 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.S.P.TR<br />

3 HOLES<br />

BOTH ENDS<br />

7.0<br />

7.0<br />

12.0<br />

6.7<br />

TYP.<br />

BOTH<br />

ENDS<br />

3/8" - 19 B.P.S.PL<br />

3 HOLES<br />

BOTH ENDS<br />

82.0<br />

27.8<br />

TYP.<br />

26.5<br />

TYP.<br />

5 1<br />

3<br />

12<br />

14<br />

12<br />

14<br />

12<br />

14<br />

12<br />

14<br />

3 1 5<br />

132.5<br />

30.9<br />

TYP.<br />

19.5<br />

TYP.<br />

14.5<br />

41.0<br />

67.5<br />

5.20 DIA. THRU.<br />

(4) MTG. HOLES<br />

16.0<br />

19.0<br />

23.5<br />

84.6<br />

35.0<br />

Number of<br />

stations<br />

XX<br />

1<br />

24.0<br />

2<br />

44.0<br />

3 4<br />

64.0 84.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

5/2 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

add-on style<br />

non plug-in cyl.<br />

ports in base<br />

with opt. F. C.<br />

35 mm<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

Valve<br />

(see base)<br />

2<br />

4<br />

12<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

A 18”<br />

1 Non-locking<br />

BA<br />

Flying leads<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

BC<br />

Flying leads with light<br />

DC 24VDC (1.8 W)<br />

x<br />

Other Options<br />

MA<br />

MC<br />

Plug-in wire assy<br />

Plug-in wire assy<br />

DD 24VDC (1.0 W)<br />

with light<br />

AA<br />

120VAC (must use with<br />

HA<br />

Plug-in connector with<br />

rectified connector)<br />

rectifier <strong>and</strong> light<br />

xx<br />

Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

EBM47A-xxxxx-xx<br />

Port size<br />

1/8” NPTF<br />

1/4” NPTF<br />

6 mm tube receptacle<br />

Bottom cylinder ports<br />

(18 mm)<br />

EBM47A-00EBA-XX<br />

EBM47A-00EBB-XX<br />

EBM47A-00EBG-XX<br />

Bottom cylinder ports with flow controls<br />

(18 mm)<br />

EBM47A-00FBA-XX<br />

EBM47A-00FBB-XX<br />

EBM47A-00FBG-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

add-a-unit stations may be added to above bars. Maximum length for add-a-unit is 4 stations.<br />

O P T I O N S<br />

EBM47A-00EBA-XX<br />

- clic replace with “C” for add-a-unit.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• Flow control kit (x2) : N-37001. End plate kit : M-47004-01.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

19.0<br />

6.7<br />

TYP.<br />

BOTH<br />

ENDS<br />

3/8" - 18 N.P.T.F.<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.S.P.TR<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.P.S.PL<br />

2 HOLES<br />

BOTH ENDS<br />

125.18<br />

54.25<br />

27.75<br />

5 1 3<br />

14<br />

14<br />

14<br />

12 12<br />

12<br />

12<br />

14<br />

5<br />

1<br />

3<br />

14.5<br />

41.0<br />

67.5<br />

4<br />

2<br />

4<br />

2<br />

4<br />

2<br />

22.0<br />

30.0<br />

7.00<br />

TYP<br />

99.3<br />

12.0<br />

21.0<br />

16.0<br />

5.20 DIA. THRU.<br />

(4) MTG. HOLES<br />

21.7<br />

TYP.<br />

18.0<br />

25.0<br />

84.6<br />

35.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size (Inlet & Exhaust) Flow (Max) Circuit bar mounting Profile<br />

non plug-in<br />

5/2 3/8” 0.5C v<br />

cyl. ports in<br />

valve with<br />

44 mm<br />

opt. Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Valve port size<br />

Valve<br />

2<br />

4<br />

12<br />

14<br />

1/8” NPTF<br />

1/4” NPTF<br />

3 1 5<br />

47A-MG0-HXXX-XXX<br />

47A-MH0-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

A 18”<br />

1 Non-locking<br />

BA<br />

Flying leads<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

BC<br />

Flying leads with light<br />

DC 24VDC (1.8 W)<br />

x<br />

Other Options<br />

MA<br />

MC<br />

Plug-in wire assy<br />

Plug-in wire assy<br />

DD 24VDC (1.0 W)<br />

with light<br />

AA<br />

120VAC (must use with<br />

HA<br />

Plug-in connector with<br />

rectified connector)<br />

rectifier <strong>and</strong> light<br />

xx<br />

Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR (REGULATOR ORDERED SEPARATELY)**<br />

EBM47A-xxxxx-xx<br />

Port size<br />

COMMON INLET & EXHAUST<br />

3/8” NPTF<br />

Without regulator<br />

(20 mm)<br />

EBM47A-01NAK-XX<br />

With regulator<br />

(20 mm)<br />

EBM47A-01PAK-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

** Pressure Regulators :<br />

PR47A-GOAx<br />

X=A (0 to 120 PSI)<br />

X=B (0 to 80 PSI)<br />

X=C (0 to 30 PSI)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


4<br />

4<br />

4<br />

4<br />

2<br />

2<br />

2<br />

2<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47002.<br />

• Regulator blanking plate : R-47003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Dim.<br />

“E”<br />

Regulator with locking<br />

adjusting screw<br />

159.8<br />

Regulator with<br />

adjusting screw<br />

155.6<br />

Regulator with<br />

adjusting knob<br />

163.6<br />

GAGE<br />

GAGE GAGE GAGE<br />

93.6<br />

5.20 DIA.<br />

4 MTG.<br />

HOLES<br />

14<br />

14<br />

14<br />

14<br />

3/8" - 18 N.P.T.F.<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.S.P.TR<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.P.S.PL<br />

2 HOLES<br />

BOTH ENDS<br />

60.8<br />

TYP.<br />

35.4<br />

TYP.<br />

5<br />

1<br />

3<br />

12<br />

12<br />

12<br />

12<br />

3 1 5<br />

19.5<br />

39.2<br />

73.5<br />

TYP.<br />

48.0<br />

TYP.<br />

23.0<br />

TYP.<br />

"E"<br />

10.0<br />

TYP.<br />

20.0<br />

25.0<br />

22.0<br />

TYP.<br />

26.2<br />

90.0<br />

44.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

5/2 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

non plug-in<br />

cyl. ports<br />

in base<br />

44 mm<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

Valve<br />

(see base)<br />

2<br />

4<br />

12<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

A 18”<br />

1 Non-locking<br />

BA<br />

Flying leads<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

BC<br />

Flying leads with light<br />

DC 24VDC (1.8 W)<br />

x<br />

Other Options<br />

MA<br />

MC<br />

Plug-in wire assy<br />

Plug-in wire assy<br />

DD 24VDC (1.0 W)<br />

with light<br />

AA<br />

120VAC (must use with<br />

HA<br />

Plug-in connector with<br />

rectified connector)<br />

rectifier <strong>and</strong> light<br />

xx<br />

Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

1/8” NPTF<br />

1/4” NPTF<br />

6 mm tube receptacle<br />

Side cylinder ports<br />

(18 mm)<br />

EBM47A-00JAA-XX<br />

EBM47A-00JAB-XX<br />

EBM47A-00JAG-XX<br />

EBM47A-xxxxx-xx<br />

Bottom cylinder ports<br />

(18 mm)<br />

EBM47A-00LAA-XX<br />

EBM47A-00LAB-XX<br />

EBM47A-00LAG-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

“D”<br />

DIMENSIONS<br />

Number of<br />

stations<br />

“A”<br />

“B”<br />

“C”<br />

1/4” Port<br />

M6 Carstick port<br />

1<br />

2<br />

3<br />

4<br />

5<br />

- 68.0 86.0 104.0 122.0 140.0 158.0 178.0 194.0 212.0<br />

25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90<br />

28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60<br />

25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00<br />

N/A<br />

6<br />

7<br />

8<br />

9<br />

10<br />

3/8" - 18 N.P.T.F.<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.S.P.TR<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.P.S.PL<br />

2 HOLES<br />

BOTH ENDS<br />

Dimensions are based on<br />

18 mm centerline spacing<br />

59.4<br />

38.3<br />

9.5<br />

34.5<br />

60.75<br />

TYP<br />

35.4<br />

TYP<br />

93.6<br />

2 2<br />

4 4<br />

"D"<br />

18.00<br />

18.00<br />

TYP<br />

"C" "B"<br />

4 4<br />

2 2<br />

"A"<br />

10.0<br />

TYP<br />

5 1 3<br />

12 12 12 12<br />

14 14 14 14<br />

3 1 5<br />

GAGE<br />

5.20 DIA.<br />

2 MTG.<br />

HOLES<br />

1/4" - 18 N.P.T.F.<br />

TYP. 2 PER STATION<br />

1/4" - 19 B.S.P.TR<br />

TYP. 2 PER STATION<br />

1/4" - 19 B.S.P.PL<br />

TYP. 2 PER STATION<br />

44.0<br />

26.20 22.00<br />

TYP TYP<br />

Note: Bottom & side cylinder ports not available on the same station<br />

23.00<br />

TYP<br />

48.00<br />

TYP<br />

73.50<br />

TYP<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

5/2 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

non plug-in<br />

cyl. ports in<br />

base with<br />

Pr. Reg.<br />

44 mm<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

Valve<br />

(see base)<br />

2<br />

4<br />

12<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

A 18”<br />

1 Non-locking<br />

BA<br />

Flying leads<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

BC<br />

Flying leads with light<br />

DC 24VDC (1.8 W)<br />

x<br />

Other Options<br />

MA<br />

MC<br />

Plug-in wire assy<br />

Plug-in wire assy<br />

DD 24VDC (1.0 W)<br />

with light<br />

AA<br />

120VAC (must use with<br />

HA<br />

Plug-in connector with<br />

rectified connector)<br />

rectifier <strong>and</strong> light<br />

xx<br />

Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR (REGULATOR ORDERED SEPARATELY)**<br />

EBM47A-xxxxx-xx<br />

Port size<br />

1/8” NPTF<br />

1/4” NPTF<br />

6 mm tube receptacle<br />

Side cylinder ports<br />

(18 mm)<br />

EBM47A-00KAA-XX<br />

EBM47A-00KAB-XX<br />

EBM47A-00KAG-XX<br />

Bottom cylinder ports<br />

(18 mm)<br />

EBM47A-00MAA-XX<br />

EBM47A-00MAB-XX<br />

EBM47A-00MAG-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

** Pressure Regulators :<br />

PR47A-GOAx<br />

X=A (0 to 120 PSI)<br />

X=B (0 to 80 PSI)<br />

X=C (0 to 30 PSI)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• Regulator blanking plate : R-47003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

3/8" - 18 N.P.T.F.<br />

2 HOLES<br />

BOTH ENDS<br />

“A”<br />

- 68.0 86.0 104.0 122.0 140.0 158.0 178.0 194.0 212.0<br />

“B”<br />

“C”<br />

1/4” Port<br />

25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90 25.90<br />

28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60 28.60<br />

25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00<br />

“D”<br />

M6 Carstick port<br />

N/A<br />

3/8" - 19 B.S.P.TR<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.P.S.PL<br />

2 HOLES<br />

BOTH ENDS<br />

Dimensions are based on<br />

18 mm centerline spacing<br />

59.4<br />

38.3<br />

9.5<br />

34.5<br />

60.75<br />

TYP<br />

35.4<br />

TYP<br />

93.6<br />

2 2<br />

4 4<br />

"D"<br />

18.00<br />

18.00<br />

TYP<br />

"C" "B"<br />

4 4<br />

2 2<br />

"A"<br />

10.0<br />

TYP<br />

3<br />

12 12 12 12<br />

5 1<br />

14 14 14 14<br />

3 1 5<br />

GAGE<br />

5.20 DIA.<br />

2 MTG.<br />

HOLES<br />

"E"<br />

1/4" - 18 N.P.T.F.<br />

TYP. 2 PER STATION<br />

1/4" - 19 B.S.P.TR<br />

TYP. 2 PER STATION<br />

1/4" - 19 B.S.P.PL<br />

TYP. 2 PER STATION<br />

Note: Bottom & side cylinder ports not available on the same station<br />

Dim.<br />

“E”<br />

Regulator with locking<br />

adjusting screw<br />

159.8<br />

Regulator with<br />

adjusting screw<br />

155.6<br />

Regulator with<br />

adjusting knob<br />

163.6<br />

44.0<br />

26.20 22.00<br />

TYP TYP<br />

23.00<br />

TYP<br />

48.00<br />

TYP<br />

73.50<br />

TYP<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

5/2 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

add-on style<br />

non plug-in<br />

cyl. ports in<br />

base<br />

44 mm<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

Valve<br />

(see base)<br />

2<br />

4<br />

12<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

A 18”<br />

1 Non-locking<br />

BA<br />

Flying leads<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

BC<br />

Flying leads with light<br />

DC 24VDC (1.8 W)<br />

x<br />

Other Options<br />

MA<br />

MC<br />

Plug-in wire assy<br />

Plug-in wire assy<br />

DD 24VDC (1.0 W)<br />

with light<br />

AA<br />

120VAC (must use with<br />

HA<br />

Plug-in connector with<br />

rectified connector)<br />

rectifier <strong>and</strong> light<br />

xx<br />

Other Options<br />

xx<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

EBM47A-xxxxx-xx<br />

Port size<br />

1/8” NPTF<br />

1/4” NPTF<br />

6 mm tube receptacle<br />

Side cylinder ports<br />

(18 mm)<br />

EBM47A-00JBA-XX<br />

EBM47A-00JBB-XX<br />

EBM47A-00JBG-XX<br />

Bottom cylinder ports<br />

(18 mm)<br />

EBM47A-00LBA-XX<br />

EBM47A-00LBB-XX<br />

EBM47A-00LBG-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

add-a-unit stations may be added to above bars. Maximum length for add-a-unit is 4 stations.<br />

O P T I O N S<br />

EBM47A-00JBA-XX<br />

- clic replace with “C” for add-a-unit.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• End plate kit : M-47005-01.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of 1 2 3 4 5 6 7 8 9 10<br />

stations<br />

“C” w/regulator<br />

“C” w/o regulator<br />

-<br />

-<br />

56.1<br />

56.1<br />

74.1<br />

74.1<br />

92.1<br />

92.1<br />

110.1 128.1 146.1 164.1 182.1 200.1<br />

110.1 128.1 146.1 164.1 182.1 200.1<br />

“D” 21.7 39.7 57.7 75.7 - - - - - -<br />

Dimensions are based on 18 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

44.0<br />

3/8" - 18 N.P.T.F.<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.S.P.TR<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.P.S.PL<br />

2 HOLES<br />

BOTH ENDS<br />

93.6<br />

59.4<br />

38.3<br />

9.5<br />

34.5<br />

16.0<br />

5 1 3<br />

5.20 DIA.<br />

2 MTG.<br />

HOLES<br />

2<br />

2<br />

4 4<br />

10.85<br />

18.00<br />

18.00<br />

25.00 "B" "A"<br />

4<br />

2<br />

"D"<br />

"C"<br />

10.0<br />

TYP<br />

12<br />

12 12<br />

3 1<br />

35.4<br />

TYP<br />

60.75<br />

TYP<br />

14 14<br />

14<br />

5<br />

GAGE<br />

1/4" - 18 N.P.T.F.<br />

TYP. 2 PER STATION<br />

1/4" - 19 B.S.P.TR<br />

TYP. 2 PER STATION<br />

1/4" - 19 B.S.P.PL<br />

TYP. 2 PER STATION<br />

1/8" - 27 N.P.T.F.<br />

TYP. 2 PER STATION<br />

1/8" - 28 B.S.P.TR.<br />

TYP. 2 PER STATION<br />

1/8" - 28 B.S.P.PL.<br />

TYP. 2 PER STATION<br />

26.20 22.00<br />

TYP TYP<br />

Dim.<br />

“A”<br />

1/4”<br />

25.90<br />

M6 Carstick<br />

25.90<br />

* M6 Carstick available only on side port<br />

23.00<br />

TYP<br />

48.00<br />

TYP<br />

73.50<br />

TYP<br />

“B”<br />

28.60<br />

28.60<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting Profile<br />

5/2 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

OPERATIONAL BENEFITS<br />

1. Direct solenoid operated valve.<br />

2. Balanced poppet, immune to variations of<br />

pressure.<br />

3. Short stroke with high flow.<br />

4. The patented solenoid develops high shifting<br />

forces.<br />

5. Powerful return spring.<br />

6. Manual operator st<strong>and</strong>ard on all valves.<br />

add-on style<br />

non plug-in cyl.<br />

ports in base<br />

with Pr. Reg.<br />

44 mm<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-Hxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

(see base)<br />

12<br />

2<br />

Valve<br />

4<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

A 18”<br />

DB 24VDC (2.4 W)<br />

C 36”<br />

DC 24VDC (1.8 W)<br />

x Other Options<br />

DD 24VDC (1.0 W)<br />

AA 120VAC (must use with<br />

rectified connector)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR (REGULATOR ORDERED SEPARATELY)**<br />

1 Non-locking<br />

BA Flying leads<br />

BC Flying leads with light<br />

MA Plug-in wire assy<br />

MC Plug-in wire assy<br />

with light<br />

HA Plug-in connector with<br />

rectifier <strong>and</strong> light<br />

xx Other Options<br />

EBM47A-xxxxx-xx<br />

Port size<br />

1/8” NPTF<br />

1/4” NPTF<br />

6 mm tube receptacle<br />

Side cylinder ports<br />

(18 mm)<br />

EBM47A-00KBA-XX<br />

EBM47A-00KBB-XX<br />

EBM47A-00KBG-XX<br />

Bottom cylinder ports<br />

(18 mm)<br />

EBM47A-00MBA-XX<br />

EBM47A-00MBB-XX<br />

EBM47A-00MBG-XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

add-a-unit stations may be added to above bars. Maximum length for add-a-unit is 4 stations.<br />

O P T I O N S<br />

EBM47A-00KBA-XX<br />

- clic replace with “C” for add-a-unit.<br />

Consult “Precautions”before use, installation or service of MAC Valves.<br />

** Pressure Regulators :<br />

PR47A-GOAx<br />

X=A (0 to 120 PSI)<br />

X=B (0 to 80 PSI)<br />

X=C (0 to 30 PSI)


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• End plate kit : M-47005-01. • Regulator blanking plate : R-47003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of 1 2 3 4 5 6 7 8 9 10<br />

stations<br />

“C” w/regulator<br />

“C” w/o regulator<br />

-<br />

-<br />

56.1<br />

56.1<br />

74.1<br />

74.1<br />

92.1<br />

92.1<br />

110.1 128.1 146.1 164.1 182.1 200.1<br />

110.1 128.1 146.1 164.1 182.1 200.1<br />

“D” 21.7 39.7 57.7 75.7 - - - - - -<br />

Dimensions are based on 18 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

44.0<br />

3/8" - 18 N.P.T.F.<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.S.P.TR<br />

2 HOLES<br />

BOTH ENDS<br />

3/8" - 19 B.P.S.PL<br />

2 HOLES<br />

BOTH ENDS<br />

93.6<br />

59.4<br />

38.3<br />

9.5<br />

34.5<br />

"E"<br />

16.0<br />

5 1 3<br />

5.20 DIA.<br />

2 MTG.<br />

HOLES<br />

2<br />

2<br />

4 4<br />

10.85<br />

18.00<br />

18.00<br />

25.00 "B" "A"<br />

4<br />

2<br />

"D"<br />

"C"<br />

10.0<br />

TYP<br />

12<br />

12 12<br />

3 1<br />

35.4<br />

TYP<br />

60.75<br />

TYP<br />

14 14<br />

14<br />

5<br />

GAGE<br />

1/4" - 18 N.P.T.F.<br />

TYP. 2 PER STATION<br />

1/4" - 19 B.S.P.TR<br />

TYP. 2 PER STATION<br />

1/4" - 19 B.S.P.PL<br />

TYP. 2 PER STATION<br />

1/8" - 27 N.P.T.F.<br />

TYP. 2 PER STATION<br />

1/8" - 28 B.S.P.TR.<br />

TYP. 2 PER STATION<br />

1/8" - 28 B.S.P.PL.<br />

TYP. 2 PER STATION<br />

Dim.<br />

1/4”<br />

M6 Carstick<br />

* M6 Carstick available only on side port<br />

26.20 22.00<br />

TYP TYP<br />

“A”<br />

“B”<br />

Dim.<br />

“E”<br />

25.90<br />

28.60<br />

25.90<br />

28.60<br />

Regulator with locking<br />

adjusting screw<br />

158.8<br />

Regulator with<br />

adjusting screw<br />

155.6<br />

Regulator with<br />

adjusting knob<br />

163.6<br />

23.00<br />

TYP<br />

48.00<br />

TYP<br />

73.50<br />

TYP<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

plug-in<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Direct solenoid operated.<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />

Valve<br />

2<br />

4<br />

12<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

DB 24VDC (2.4 W)<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DD 24VDC (1.0 W)<br />

FG Plug-in with suppression diode<br />

AA 120VAC (Mod. No. required see below)<br />

with LED light<br />

xx Other Options<br />

xx Other Options<br />

FA<br />

FC<br />

FE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR<br />

ECD47A-xxxxx-xxxx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

18<br />

ECD47A-00AAA-A0XX<br />

ECD47A-00BAA-A0XX<br />

1/4” NPTF<br />

18<br />

ECD47A-00AAB-A0XX<br />

ECD47A-00BAB-A0XX<br />

6 mm tube receptacle<br />

18<br />

ECD47A-00AAG-A0XX<br />

ECD47A-00BAG-A0XX<br />

1/8” NPTF<br />

30<br />

ECD47A-01AAA-C0XX<br />

ECD47A-01BAA-C0XX<br />

1/4” NPTF<br />

30<br />

ECD47A-01AAB-C0XX<br />

ECD47A-01BAB-C0XX<br />

6 mm tube receptacle<br />

30<br />

ECD47A-01AAG-C0XX<br />

ECD47A-01BAG-C0XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

for multi-pin connector (9, 15 or 25).<br />

Consult “Precautions”before use, installation or service of MAC Valves.<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• Base wire plug-in protector : 16520.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

“E”<br />

46.0<br />

64.0<br />

82.0<br />

100.0 118.0 136.0 154.0 172.0 190.0 208.0<br />

Dimensions are based on 18 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

136.5<br />

3/8 N.P.T.F.<br />

3 HOLES<br />

BOTH ENDS<br />

SHOWN W\ STANDARD<br />

REGULATOR<br />

COND.<br />

5<br />

1<br />

3<br />

79.5<br />

40.7<br />

20.35<br />

44.0<br />

19.0 23.2<br />

28.0<br />

TYP. TYP. TYP.<br />

59.05<br />

TYP. 6.0<br />

TYP.<br />

21.0<br />

TYP.<br />

45.1<br />

TYP.<br />

73.0<br />

TYP.<br />

107.5<br />

TYP.<br />

D<br />

14<br />

14<br />

12<br />

12<br />

2<br />

18.0<br />

TYP.<br />

E<br />

14<br />

14<br />

2<br />

12<br />

4<br />

2<br />

4<br />

12<br />

4<br />

COND.<br />

5<br />

1<br />

3<br />

6.25 DIA.<br />

2 MTG.<br />

HOLES<br />

1"-11 1/2 N.P.S.M. CONDUIT<br />

34.5<br />

9.5<br />

C<br />

A<br />

B<br />

23.0 23.0<br />

18.0<br />

TYP.<br />

18.0<br />

TYP.<br />

2<br />

4<br />

18.0<br />

TYP.<br />

Dim.<br />

1/4”<br />

1/8”<br />

6 mm Legris<br />

“A”<br />

26.65<br />

26.15<br />

25.65<br />

“B”<br />

26.65<br />

24.2<br />

25.65<br />

“C”<br />

33.1<br />

34.8<br />

34.8<br />

“D”<br />

58.4<br />

55.9<br />

55.9<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 1/8” - 1/4” 0.5C v<br />

plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Direct solenoid operated.<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />

Valve<br />

12<br />

2<br />

4<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

DB 24VDC (2.4 W)<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DD 24VDC (1.0 W)<br />

FG Plug-in with suppression diode<br />

AA 120VAC (Mod. No. required see below)<br />

with LED light<br />

xx Other Options<br />

xx Other Options<br />

FA<br />

FC<br />

FE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />

ECD47A-xxxxx-xxxx<br />

Port size<br />

Spacing mm<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

1/4” NPTF<br />

1/8” NPTF<br />

1/4” NPTF<br />

18<br />

18<br />

30<br />

30<br />

ECD47A-00CAA-A0XX<br />

ECD47A-00CAB-A0XX<br />

ECD47A-01CAA-C0XX<br />

ECD47A-01CAB-C0XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

for multi-pin connector (9, 15 or 25).<br />

** Pressure Regulators :<br />

PR47A-GOAx<br />

X=A (0 to 120 PSI)<br />

X=B (0 to 80 PSI)<br />

X=C (0 to 30 PSI)<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• Base wire plug-in protector : 16520. • Regulator blanking plate : R-47003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

“E”<br />

46.0<br />

64.0<br />

82.0<br />

100.0 118.0 136.0 154.0 172.0 190.0 208.0<br />

Dimensions are based on 18 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

F<br />

G<br />

SHOWN W\ SANDWICH<br />

REGULATOR<br />

136.5<br />

3/8 N.P.T.F.<br />

3 HOLES<br />

BOTH ENDS<br />

SHOWN W\ STANDARD<br />

REGULATOR<br />

COND.<br />

5<br />

1<br />

3<br />

79.5<br />

40.7<br />

20.35<br />

44.0<br />

19.0 23.2<br />

28.0<br />

TYP. TYP. TYP.<br />

59.05<br />

TYP. 6.0<br />

TYP.<br />

21.0<br />

TYP.<br />

45.1<br />

TYP.<br />

73.0<br />

TYP.<br />

107.5<br />

TYP.<br />

D<br />

14<br />

14<br />

14<br />

12<br />

12<br />

12<br />

2<br />

18.0<br />

TYP.<br />

E<br />

14<br />

12<br />

2<br />

4<br />

COND.<br />

5<br />

1<br />

3<br />

6.25 DIA.<br />

2 MTG.<br />

HOLES<br />

1"-11 1/2 N.P.S.M. CONDUIT<br />

34.5<br />

9.5<br />

C<br />

A<br />

B<br />

23.0 23.0<br />

Dim.<br />

1/4”<br />

1/8”<br />

6 mm Legris<br />

18.0<br />

TYP.<br />

18.0<br />

TYP.<br />

2<br />

4<br />

18.0<br />

TYP.<br />

“A”<br />

“B”<br />

“C”<br />

26.65<br />

26.65<br />

33.1<br />

26.15<br />

24.2<br />

34.8<br />

25.65<br />

25.65<br />

34.8<br />

4<br />

2<br />

4<br />

“D”<br />

58.4<br />

55.9<br />

55.9<br />

109.2<br />

Dim.<br />

“F”<br />

Regulator with locking<br />

adjusting screw<br />

209.3<br />

Regulator with<br />

adjusting screw<br />

205.1<br />

Regulator with<br />

adjusting knob<br />

212.1<br />

“G”<br />

204.3<br />

200.1<br />

207.1<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

add-on style<br />

plug-in<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Direct solenoid operated.<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />

Valve<br />

2<br />

4<br />

12<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

DB 24VDC (2.4 W)<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DD 24VDC (1.0 W)<br />

FG Plug-in with suppression diode<br />

AA 120VAC (Mod. No. required see below)<br />

with LED light<br />

xx Other Options<br />

xx Other Options<br />

FA<br />

FC<br />

FE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR<br />

ECD47A-xxxxx-xxxx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

18<br />

ECD47A-00ABA-A0XX<br />

ECD47A-00BBA-A0XX<br />

1/4” NPTF<br />

18<br />

ECD47A-00ABB-A0XX<br />

ECD47A-00BBB-A0XX<br />

6 mm tube receptacle<br />

18<br />

ECD47A-00ABG-A0XX<br />

ECD47A-00BBG-A0XX<br />

1/8” NPTF<br />

30<br />

ECD47A-01ABA-C0XX<br />

ECD47A-01BBA-C0XX<br />

1/4” NPTF<br />

30<br />

ECD47A-01ABB-C0XX<br />

ECD47A-01BBB-C0XX<br />

6 mm tube receptacle<br />

30<br />

ECD47A-01ABG-C0XX<br />

ECD47A-01BBG-C0XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

for multi-pin connector (9, 15 or 25).<br />

add-a-units may be added to above bars.<br />

Consult “Precautions”before use, installation or service of MAC Valves.<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)


2<br />

4<br />

2<br />

4<br />

2<br />

4<br />

2<br />

4<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• Base wire plug-in protector : 16520. • Isolator disc between add-a-units : 28438.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

“G”<br />

“H”<br />

1<br />

2<br />

3<br />

4<br />

5<br />

- 51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />

21.70 39.70 57.70 75.70 - - - - - -<br />

6<br />

7<br />

8<br />

9<br />

10<br />

137.7<br />

1"-11 1/2 N.P.S.M. CONDUIT<br />

Dimensions are based on 18 mm centerline spacing<br />

1 3<br />

COND.<br />

Note: Bottom & side cylinder ports not available on the same station<br />

5<br />

79.2<br />

3/8" N.PT.F.<br />

TYP.(3) BOTH ENDS<br />

E<br />

16.0<br />

4<br />

2<br />

12.05<br />

F<br />

12<br />

14<br />

H<br />

4<br />

2<br />

13.0<br />

12<br />

14<br />

4<br />

4<br />

2<br />

2<br />

16.7<br />

18.0<br />

TYP.<br />

26.15<br />

12<br />

A<br />

12<br />

14<br />

14<br />

G<br />

D<br />

C<br />

B<br />

9.5<br />

TYP.<br />

34.5<br />

TYP.<br />

6.0 59.05<br />

TYP. TYP.<br />

6.25 DIA. HOLE<br />

TYP.(2)<br />

44.0<br />

40.7<br />

23.2 19.0<br />

3<br />

5<br />

20.35 28.0<br />

TYP. TYP. 1 COND. TYP. TYP.<br />

Dim.<br />

“A”<br />

“B”<br />

“C”<br />

“D”<br />

“E”<br />

1/8”<br />

24.20<br />

23.00<br />

34.80<br />

55.90<br />

-<br />

1/4”<br />

24.20<br />

23.00<br />

33.10<br />

58.40<br />

-<br />

6 mm Legris<br />

25.65<br />

23.00<br />

34.80<br />

55.90<br />

-<br />

21.0<br />

TYP.<br />

45.1<br />

TYP.<br />

73.0<br />

TYP.<br />

107.5<br />

TYP.<br />

“F”<br />

12.05<br />

12.00<br />

14.00<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 1/8” - 1/4” 0.5C v<br />

add-on style<br />

plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Direct solenoid operated.<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />

Valve<br />

12<br />

2<br />

4<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

DB 24VDC (2.4 W)<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DD 24VDC (1.0 W)<br />

FG Plug-in with suppression diode<br />

AA 120VAC (Mod. No. required see below)<br />

with LED light<br />

xx Other Options<br />

xx Other Options<br />

FA<br />

FC<br />

FE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />

ECD47A-xxxxx-xxxx<br />

Port size<br />

Spacing mm<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

1/4” NPTF<br />

1/8” NPTF<br />

1/4” NPTF<br />

18<br />

18<br />

30<br />

30<br />

ECD47A-00CBA-A0XX<br />

ECD47A-00CBB-A0XX<br />

ECD47A-01CBA-C0XX<br />

ECD47A-01CBB-C0XX<br />

Number of stations (03=3 stations)<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

for multi-pin connector (9, 15 or 25).<br />

add-a-units may be added to above bars.<br />

** Pressure Regulators :<br />

PR47A-GOAx<br />

X=A (0 to 120 PSI)<br />

X=B (0 to 80 PSI)<br />

X=C (0 to 30 PSI)<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• Base wire plug-in protector : 16520. • Regulator blanking plate : R-47003. • Isolator disc between add-a-units : 28438.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

“G” w/regulator<br />

1<br />

-<br />

2<br />

3<br />

4<br />

5<br />

6<br />

54.40 72.40 90.40 108.40 126.40 144.40 162.40 180.40 199.40<br />

7<br />

8<br />

9<br />

10<br />

SHOWN W/STANDARD<br />

REGULATOR<br />

J<br />

137.7<br />

1"-11 1/2 N.P.S.M. CONDUIT<br />

“G” w/o regulator - 51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />

“H” w/regulator 24.25 42.25 60.25 78.25 - - - - - -<br />

1 3<br />

COND.<br />

“H” w/o regulator 21.70 39.70 57.70 75.70<br />

Dimensions are based on 18 mm<br />

centerline spacing<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

3/8" N.PT.F.<br />

TYP.(3) BOTH ENDS<br />

5<br />

79.2<br />

Note: Bottom & side cylinder ports not<br />

available on the same station<br />

E<br />

16.0<br />

4<br />

2<br />

12.05<br />

F<br />

12<br />

14<br />

H<br />

4<br />

2<br />

13.0<br />

4<br />

2<br />

12<br />

14<br />

4<br />

16.7<br />

18.0<br />

TYP.<br />

26.15<br />

12<br />

4<br />

2<br />

2<br />

A<br />

2<br />

4<br />

12<br />

14<br />

14<br />

G<br />

D<br />

C<br />

B<br />

9.5<br />

TYP.<br />

34.5<br />

TYP.<br />

6.0 59.05<br />

TYP. TYP.<br />

K<br />

SHOWN W/SANDWICH<br />

REGULATOR<br />

6.25 DIA. HOLE<br />

TYP.(2)<br />

Dim.<br />

“A”<br />

“B”<br />

“C”<br />

“D”<br />

“E”<br />

“F”<br />

Dim.<br />

“J”<br />

“K”<br />

1/8”<br />

24.20<br />

23.00<br />

34.80<br />

55.90<br />

-<br />

12.05<br />

1/4”<br />

24.20<br />

23.00<br />

33.10<br />

58.40<br />

-<br />

12.00<br />

Regulator with locking<br />

adjusting screw<br />

209.3<br />

204.3<br />

6 mm Legris<br />

25.65<br />

23.00<br />

34.80<br />

55.90<br />

-<br />

14.00<br />

1/8” w/regulator<br />

-<br />

-<br />

34.80<br />

55.90<br />

10.75<br />

-<br />

1/4” w/regulator<br />

-<br />

23.00<br />

33.10<br />

58.40<br />

10.85<br />

-<br />

Regulator with<br />

adjusting screw<br />

205.1<br />

200.1<br />

Regulator with<br />

adjusting knob<br />

212.1<br />

207.1<br />

103.0<br />

44.0<br />

40.7<br />

23.2 19.0<br />

3<br />

5<br />

20.35 28.0<br />

TYP. TYP. 1 COND. TYP. TYP.<br />

21.0<br />

TYP.<br />

45.1<br />

TYP.<br />

73.0<br />

TYP.<br />

107.5<br />

TYP.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 1/8” - 1/4” 0.5C v<br />

6 mm tube receptacle<br />

plug-in<br />

add-a-unit<br />

stations<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Direct solenoid operated.<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />

Valve<br />

2<br />

4<br />

12<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

DB 24VDC (2.4 W)<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DD 24VDC (1.0 W)<br />

FG Plug-in with suppression diode<br />

AA 120VAC (Mod. No. required see below)<br />

with LED light<br />

xx Other Options<br />

xx Other Options<br />

FA<br />

FC<br />

FE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR<br />

ECD47A-xxxxx-xxxx<br />

Port size<br />

Spacing<br />

mm<br />

Side cylinder ports<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

18<br />

ECD47A-00ACA-A0XX<br />

ECD47A-00BCA-A0XX<br />

1/4” NPTF<br />

18<br />

ECD47A-00ACB-A0XX<br />

ECD47A-00BCB-A0XX<br />

6 mm tube receptacle<br />

18<br />

ECD47A-00ACG-A0XX<br />

ECD47A-00BCG-A0XX<br />

1/8” NPTF<br />

30<br />

ECD47A-01ACA-C0XX<br />

ECD47A-01BCA-C0XX<br />

1/4” NPTF<br />

30<br />

ECD47A-01ACB-C0XX<br />

ECD47A-01BCB-C0XX<br />

6 mm tube receptacle<br />

30<br />

ECD47A-01ACG-C0XX<br />

ECD47A-01BCG-C0XX<br />

Number of stations (01=1 station). Maximum length is 4 stations<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

when add-a-unit stations are added to bars with a multi-pin connector,<br />

MOD SD03 should be included with add-a-unit model number.<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

Consult “Precautions”before use, installation or service of MAC Valves.<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)


2<br />

4<br />

2<br />

4<br />

2<br />

4<br />

2<br />

4<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• O-ring port seal (x3) : 17015-01 • Tie rod (x2) : 79007-01 (one station length).<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

“G”<br />

“H”<br />

1<br />

2<br />

3<br />

4<br />

5<br />

- 51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />

21.70 39.70 57.70 75.70 - - - - - -<br />

6<br />

7<br />

8<br />

9<br />

10<br />

137.7<br />

1"-11 1/2 N.P.S.M. CONDUIT<br />

Dimensions are based on 18 mm centerline spacing<br />

1 3<br />

COND.<br />

Note: Bottom & side cylinder ports not available on the same station<br />

5<br />

79.2<br />

3/8" N.PT.F.<br />

TYP.(3) BOTH ENDS<br />

E<br />

16.0<br />

4<br />

2<br />

12.05<br />

F<br />

12<br />

14<br />

H<br />

4<br />

2<br />

13.0<br />

12<br />

14<br />

4<br />

4<br />

2<br />

2<br />

16.7<br />

18.0<br />

TYP.<br />

26.15<br />

12<br />

A<br />

12<br />

14<br />

14<br />

G<br />

D<br />

C<br />

B<br />

9.5<br />

TYP.<br />

34.5<br />

TYP.<br />

6.0 59.05<br />

TYP. TYP.<br />

6.25 DIA. HOLE<br />

TYP.(2)<br />

44.0<br />

40.7<br />

23.2 19.0<br />

3<br />

5<br />

20.35 28.0<br />

TYP. TYP. 1 COND. TYP. TYP.<br />

Dim.<br />

“A”<br />

“B”<br />

“C”<br />

“D”<br />

“E”<br />

1/8”<br />

24.20<br />

23.00<br />

34.80<br />

55.90<br />

-<br />

1/4”<br />

24.20<br />

23.00<br />

33.10<br />

58.40<br />

-<br />

6 mm Legris<br />

25.65<br />

23.00<br />

34.80<br />

55.90<br />

-<br />

21.0<br />

TYP.<br />

45.1<br />

TYP.<br />

73.0<br />

TYP.<br />

107.5<br />

TYP.<br />

“F”<br />

12.05<br />

12.00<br />

14.00<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 47<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 1/8” - 1/4” 0.5C v<br />

add-a-unit<br />

stations<br />

plug-in<br />

with Pr. Reg.<br />

OPERATIONAL BENEFITS<br />

1. Balanced poppet, immune to variations of<br />

pressure.<br />

2. Short stroke with high flow.<br />

3. The patented solenoid develops high shifting<br />

forces.<br />

4. Powerful return spring.<br />

5. Manual operator st<strong>and</strong>ard on all valves.<br />

6. Direct solenoid operated.<br />

Reset<br />

HOW TO ORDER<br />

47A-xxx-HxxP-xxx<br />

HOW TO ORDER VALVE FOR “PLUG-IN” CIRCUIT BAR<br />

Valve<br />

12<br />

2<br />

4<br />

14<br />

Valve less base<br />

3 1 5<br />

47A-LI0-HXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

H XX P- X XX *<br />

XX Voltage<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

DA 24VDC (5.2 W)<br />

DB 24VDC (2.4 W)<br />

DC 24VDC (1.8 W)<br />

1 Non-locking<br />

DD 24VDC (1.0 W)<br />

FG Plug-in with suppression diode<br />

AA 120VAC (Mod. No. required see below)<br />

with LED light<br />

xx Other Options<br />

xx Other Options<br />

FA<br />

FC<br />

FE<br />

Plug-in<br />

Plug-in with light<br />

Plug-in with suppression diode<br />

HOW TO ORDER “PLUG-IN” CIRCUIT BAR (REGULATORS ORDERED SEPARATELY)**<br />

ECD47A-xxxxx-xxxx<br />

Port size<br />

Spacing mm<br />

Bottom cylinder ports<br />

1/8” NPTF<br />

1/4” NPTF<br />

1/8” NPTF<br />

1/4” NPTF<br />

18<br />

18<br />

30<br />

30<br />

ECD47A-00CCA-A0XX<br />

ECD47A-00CCB-A0XX<br />

ECD47A-01CCA-C0XX<br />

ECD47A-01CCB-C0XX<br />

Number of stations (01=1 station). Maximum length is 4 stations<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

when add-a-unit stations are added to bars with a multi-pin connector,<br />

MOD SD03 should be included with add-a-unit model number.<br />

for AC voltage use mod. FWR2 after circuit bar model number.<br />

** Pressure Regulators :<br />

PR47A-GOAx<br />

X=A (0 to 120 PSI)<br />

X=B (0 to 80 PSI)<br />

X=C (0 to 30 PSI)<br />

A0 = without light<br />

AA = with light (120V)<br />

AB = with light (240V)<br />

AD = with light (24V)<br />

C0 = terminal strip<br />

CA = terminal strip with light (120V)<br />

CB = terminal strip with light (240V)<br />

CD = terminal strip with light (24V)<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 47<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Power :<br />

Response times :<br />

(with 5.2 W coil)<br />

Compressed air, vacuum, inert gases<br />

Vacuum to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F <strong>and</strong> 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to 50°C)<br />

4.3 mm<br />

5.2 W : 0.50C v , 2.4 W : 0.30C v , 1.8 W : 0.25C v , 1.0 W : 0.25C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

5.2 W - 2.4 W - 1.8 W - 1.0 W<br />

Energize : 14.0 ms<br />

De-energize : 5.0 ms<br />

Note :<br />

Spare parts :<br />

Options :<br />

• Valve <strong>and</strong> coil are not interchangeable.<br />

• Seal between valve <strong>and</strong> bar : 16629. • Mounting screw (x2) : 35043. • Valve blanking plate : M-47001.<br />

• O-ring port seal (x3) : 17015-01 • Tie rod (x2) : 79007-01 (one station length). • Regulator blanking plate : R-47003.<br />

• Isolation of inlet <strong>and</strong>/or exhaust. Special bar. Consult factory. • BSPP Threads.<br />

DIMENSIONS<br />

Number of<br />

stations<br />

“G” w/regulator<br />

1<br />

-<br />

2<br />

3<br />

4<br />

5<br />

6<br />

54.40 72.40 90.40 108.40 126.40 144.40 162.40 180.40 199.40<br />

7<br />

8<br />

9<br />

10<br />

SHOWN W/STANDARD<br />

REGULATOR<br />

J<br />

137.7<br />

1"-11 1/2 N.P.S.M. CONDUIT<br />

“G” w/o regulator - 51.85 69.85 87.85 105.85 123.85 141.85 159.85 177.85 195.85<br />

“H” w/regulator 24.25 42.25 60.25 78.25 - - - - - -<br />

1 3<br />

COND.<br />

“H” w/o regulator 21.70 39.70 57.70 75.70<br />

Dimensions are based on 18 mm<br />

centerline spacing<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

3/8" N.PT.F.<br />

TYP.(3) BOTH ENDS<br />

5<br />

79.2<br />

Note: Bottom & side cylinder ports not<br />

available on the same station<br />

E<br />

16.0<br />

4<br />

2<br />

12.05<br />

F<br />

12<br />

14<br />

H<br />

4<br />

2<br />

13.0<br />

4<br />

2<br />

12<br />

14<br />

4<br />

16.7<br />

18.0<br />

TYP.<br />

26.15<br />

12<br />

4<br />

2<br />

2<br />

A<br />

2<br />

4<br />

12<br />

14<br />

14<br />

G<br />

D<br />

C<br />

B<br />

9.5<br />

TYP.<br />

34.5<br />

TYP.<br />

6.0 59.05<br />

TYP. TYP.<br />

K<br />

SHOWN W/SANDWICH<br />

REGULATOR<br />

6.25 DIA. HOLE<br />

TYP.(2)<br />

Dim.<br />

“A”<br />

“B”<br />

“C”<br />

“D”<br />

“E”<br />

“F”<br />

Dim.<br />

“J”<br />

“K”<br />

1/8”<br />

24.20<br />

23.00<br />

34.80<br />

55.90<br />

-<br />

12.05<br />

1/4”<br />

24.20<br />

23.00<br />

33.10<br />

58.40<br />

-<br />

12.00<br />

Regulator with locking<br />

adjusting screw<br />

209.3<br />

204.3<br />

6 mm Legris<br />

25.65<br />

23.00<br />

34.80<br />

55.90<br />

-<br />

14.00<br />

1/8” w/regulator<br />

-<br />

-<br />

34.80<br />

55.90<br />

10.75<br />

-<br />

1/4” w/regulator<br />

-<br />

23.00<br />

33.10<br />

58.40<br />

10.85<br />

-<br />

Regulator with<br />

adjusting screw<br />

205.1<br />

200.1<br />

Regulator with<br />

adjusting knob<br />

212.1<br />

207.1<br />

103.0<br />

44.0<br />

40.7<br />

23.2 19.0<br />

3<br />

5<br />

20.35 28.0<br />

TYP. TYP. 1 COND. TYP. TYP.<br />

21.0<br />

TYP.<br />

45.1<br />

TYP.<br />

73.0<br />

TYP.<br />

107.5<br />

TYP.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Section 2 Options<br />

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Codification table for voltages / Wire length / Manual operators / Electrical connections<br />

VALVE CODE ➤<br />

- H XX X - X XX<br />

1 2 3 4<br />

OPTIONS AVAILABLE FOR<br />

- Solenoid valves 37 & 47 Series<br />

Consult “Precautions”before use, installation or service of MAC Valves.


OPTIONS<br />

Back<br />

1. VOLTAGE<br />

- H XX X - X XX VOLTAGE<br />

DC Options<br />

DA 24 VDC (5.2 W)<br />

DB 24 VDC (2.4 W)<br />

DC 24 VDC (1.8 W)<br />

DD 24 VDC (1.0 W)<br />

DF 12 VDC (5.2 W)<br />

DG 12 VDC (2.4 W)<br />

DH 12 VDC (1.8 W)<br />

DJ 12 VDC (1.0 W)<br />

DL 120 VDC (6.3 W)<br />

AC Options (50/60hz)<br />

AA 120 VAC (6.7 W)<br />

AB 220 VAC (5.6 W)<br />

AC 240 VAC (5.8 W)<br />

AD 24 VAC (7.8 W)<br />

Note : AC Voltages only available with “H” & “F” type connectors. MOD FWR2 must be used with the “F” type connectors.<br />

2. WIRE LENGTH<br />

- H XX X - X XX WIRE LENGTH<br />

O<br />

No lead wire<br />

A 18”<br />

B 24”<br />

C 36”<br />

D 48”<br />

E 72”<br />

F 96”<br />

G 120”<br />

H 144”<br />

P<br />

Plug-in (used only with “F”type connector Opts.)<br />

Use “O” with MJ & MM Opts.<br />

3. MANUAL OPERATOR<br />

- H XX X - X XX MANUAL OPERATOR<br />

0 No operator<br />

1 Non-locking recessed<br />

2 Locking recessed<br />

3 Non-locking extended<br />

4 Locking extended<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Back<br />

4. ELECTRICAL CONNECTION<br />

- H XX X - X XX ELECTRICAL CONNECTION<br />

BA Flying leads<br />

BB Flying leads with ground wire<br />

BC Flying leads with led light<br />

BD Flying leads with led light & ground wire<br />

BE Flying leads with suppression diode<br />

BF Flying leads with suppression diode & ground wire<br />

BG Flying leads with suppression diode plus led light<br />

BH Flying leads with suppression diode plus led light & ground wire<br />

*BN Flying leads with suppression diode plus blocking diode<br />

*BP Flying leads with suppression diode plus blocking diode & ground wire<br />

*BR Flying leads with suppression diode plus blocking diode & led light<br />

*BS Flying leads with suppression diode plus blocking diode & led light & ground wire<br />

FA<br />

FB<br />

FC<br />

FD<br />

FE<br />

FF<br />

FG<br />

FH<br />

Plug-in<br />

Plug-in with ground wire<br />

Plug-in with led light<br />

Plug-in with led light & ground wire<br />

Plug-in with suppression diode<br />

Plug-in with suppression diode & ground wire<br />

Plug-in with suppression diode plus led light<br />

Plug-in with suppression diode plus led light & ground wire<br />

Note : FA ---- FH options for use with ECD type circuit bars<br />

HA<br />

HB<br />

HC<br />

HD<br />

HL<br />

HN<br />

Circuit board plug-in with full wave rectifier & led light<br />

Circuit board with full wave rectifier & led with ground wire<br />

Same as “HA” without lead wires<br />

Same as “HB” without lead wires<br />

Circuit board plug-in with suppression diode plus blocking diode & led light<br />

Same as “HL” without lead wires<br />

MA Plug-in wire assembly<br />

MB Plug-in wire assembly with ground wire<br />

MC Plug-in wire assembly with led light<br />

MD Plug-in wire assembly led light & ground wire<br />

ME Plug-in wire assembly with suppression diode<br />

MF Plug-in wire assembly with suppression diode & ground wire<br />

*MG Plug-in wire assembly suppression diode plus led light<br />

*MH Plug-in wire assembly suppression diode plus led light & ground wire<br />

*MN Plug-in wire assembly with suppression diode plus blocking diode<br />

*MP Plug-in wire assembly with suppression diode plus blocking diode & ground wire<br />

MR Plug-in wire assembly with suppression diode plus blocking diode & led light<br />

MS Plug-in wire assembly with suppression diode plus blocking diode & led light & ground wire<br />

MJ Plug-in housing w/o wire assembly (“MA” option without wire assembly)<br />

MM Plug-in housing w/o wire assembly (“MB” option without wire assembly)<br />

* Blocking diode is in lead wire.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

PIN #6<br />

PIN #9<br />

MOD. SD09<br />

PIN #1<br />

PIN #5<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 9<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 7 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 2 common wires<br />

PIN #9<br />

PIN #15<br />

MOD. SD15<br />

PIN #1<br />

PIN #8<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 15<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 12 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 3 common wires<br />

PIN #14<br />

PIN #25<br />

MOD. SD25<br />

PIN #1<br />

PIN #13<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 25<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 20 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 5 common wires<br />

Note : Use desired MOD. number after circuit bar part number


O p t i o n s<br />

OPTIONS<br />

Connector termination details<br />

CONNECTOR<br />

SOL 1<br />

SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />

Single solenoid circuit bar<br />

SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />

CONNECTOR<br />

SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />

Double solenoid circuit bar<br />

SD09 SD15 SD25<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

8<br />

COMMON (+)<br />

13<br />

COMMON (+)<br />

21<br />

COMMON (+)<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

9<br />

COMMON (+)<br />

8<br />

SOL. 8<br />

8<br />

SOL. 8<br />

14<br />

COMMON (+)<br />

22<br />

COMMON (+)<br />

9<br />

SOL. 9<br />

9<br />

SOL. 9<br />

10 SOL. 10<br />

10 SOL. 10<br />

11<br />

SOL. 11<br />

11<br />

SOL. 11<br />

12 SOL. 12<br />

12 SOL. 12<br />

15<br />

COMMON (+)<br />

23<br />

COMMON (+)<br />

13<br />

SOL. 13<br />

14 SOL. 14<br />

15<br />

SOL. 15<br />

16 SOL. 16<br />

24<br />

COMMON (+)<br />

17<br />

18 SOL. 18<br />

19<br />

20 SOL. 20<br />

SOL. 17<br />

SOL. 19<br />

25<br />

COMMON (+)


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Circuit bar mounting<br />

low profile<br />

cylinder ports<br />

in valve<br />

low profile<br />

cylinder ports<br />

in base<br />

mid profile<br />

cylinder ports<br />

in valve<br />

mid profile -<br />

add on style<br />

cylinder ports<br />

in valve<br />

add-a-unit<br />

stations for<br />

CBM403A bar<br />

mid profile<br />

cylinder ports<br />

in base<br />

mid profile -<br />

add on style<br />

cylinder ports<br />

in base<br />

add-a-unit<br />

stations for<br />

CBM404A bar<br />

high profile<br />

cylinder ports<br />

in base<br />

high profile -<br />

add on style<br />

cylinder ports<br />

in base<br />

add-a-unit<br />

stations for<br />

CBM405A bar<br />

Manual operator<br />

Solenoid<br />

4-way pilot with balanced poppet<br />

Bonded spool<br />

2 4<br />

Air return<br />

3<br />

1 5<br />

SERIES FEATURES<br />

• Patented MACSOLENOID ® for fastest possible response times<br />

<strong>and</strong> virtually burn-out proof AC solenoid operation.<br />

• Optional low watt DC solenoids.<br />

• Various manual operators.<br />

• Optional memory spring.<br />

• 2 position or 3 position valve configurations.<br />

• Internal or external pilot.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” - 1/4” 1.0C v<br />

low profile<br />

cylinder ports<br />

in valve<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

1/8” NPT<br />

Internal<br />

315<br />

411A-AOA-DM-DXXX-XXX<br />

411A-COA-DM-DXXX-XXX<br />

315<br />

421A-AOA-DM-DXXX-XXX<br />

315<br />

451A-AOA-DM-DXXX-XXX<br />

315<br />

461A-AOA-DM-DXXX-XXX<br />

315<br />

471A-AOA-DM-DXXX-XXX<br />

1/4” NPT<br />

411A-BOA-DM-DXXX-XXX<br />

421A-BOA-DM-DXXX-XXX<br />

451A-BOA-DM-DXXX-XXX<br />

461A-BOA-DM-DXXX-XXX<br />

471A-BOA-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

JA 120/60, 110/50<br />

JC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

A<br />

J<br />

x<br />

18” (Flying leads)<br />

Connector<br />

Other Options<br />

1 Non-locking<br />

2 Locking<br />

x Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

CBM401A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard 19,5 mm<br />

w/o flow controls<br />

w/ flow controls<br />

Spacing 26 mm (Rectangular connector)<br />

w/o flow controls<br />

w/ flow controls<br />

3/8” NPTF<br />

Internal<br />

CBM401A-00AAA-XX<br />

CBM401A-00BAA-XX<br />

CBM401A-02AAA-XX<br />

CBM401A-02BAA-XX<br />

Number of stations (03=3 stations)<br />

** Other options available. Consult factory.<br />

O P T I O N S<br />

411A-AOA-DM-DXXX-XXX<br />

- clic with memory spring (replace by 4).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Compressed air, vacuum, inert gases<br />

20 - 150 PSI<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.<br />

• Mounting screw (x2) : 35043.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

108.5 94.3<br />

18.5<br />

16.0<br />

C L<br />

14.5<br />

14<br />

14<br />

14<br />

14<br />

3<br />

5 1<br />

12<br />

12<br />

12<br />

12<br />

3 1 5<br />

82.0<br />

118.0 DOUBLE<br />

108.2 SINGLE<br />

41.0<br />

67.5<br />

94.5<br />

7.0<br />

25.0 39.0 19.5<br />

6.7<br />

21.5<br />

32.0<br />

C L<br />

3/8" PORTS<br />

TYP.<br />

É” 6.50 TYP.<br />

1/8" PORTS<br />

TYP.<br />

27.8<br />

31.5<br />

50.7<br />

25.0<br />

64.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” 1.0C v<br />

low profile<br />

cylinder ports<br />

in base<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

Internal<br />

315<br />

413A-OOA-DM-DXXX-XXX<br />

315<br />

423A-OOA-DM-DXXX-XXX<br />

315<br />

453A-OOA-DM-DXXX-XXX<br />

315<br />

463A-OOA-DM-DXXX-XXX<br />

315<br />

473A-OOA-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

JA 120/60, 110/50<br />

JC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

A<br />

J<br />

x<br />

18” (Flying leads)<br />

Connector<br />

Other Options<br />

1 Non-locking<br />

2 Locking<br />

x Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) **<br />

CBM402A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard 19,5 mm<br />

w/o flow controls<br />

w/ flow controls<br />

Spacing 26 mm (Rectangular connector)<br />

w/o flow controls<br />

w/ flow controls<br />

1/8” NPTF<br />

Internal<br />

CBM402A-00AAA-XX<br />

CBM402A-00BAA-XX<br />

CBM402A-02AAA-XX<br />

CBM402A-02BAA-XX<br />

Number of stations (03=3 stations)<br />

** Other options available. Consult factory.<br />

O P T I O N S<br />

413A-OOA-DM-DXXX-XXX<br />

- clic with memory spring (replace by 6).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Compressed air, vacuum, inert gases<br />

20 - 150 PSI<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.<br />

• Mounting screw (x2) : 35043.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

108.5 94.3<br />

18.5<br />

16.0<br />

C L<br />

14.5<br />

14<br />

14<br />

14<br />

14<br />

3<br />

5 1<br />

12<br />

12<br />

12<br />

12<br />

3 1 5<br />

82.0<br />

118.0 DOUBLE<br />

108.2 SINGLE<br />

41.0<br />

67.5<br />

94.5<br />

7.0<br />

6.7<br />

21.5<br />

32.0<br />

C L<br />

3/8" PORTS<br />

TYP.<br />

Ø 6.50 TYP.<br />

1/8" PORTS<br />

TYP.<br />

27.8<br />

31.5<br />

50.7<br />

25.0<br />

64.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” - 1/4” 1.0C v<br />

mid profile<br />

cylinder ports<br />

in valve<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

1/8” NPT<br />

Internal<br />

315<br />

411A-AOA-DM-DXXX-XXX<br />

411A-COA-DM-DXXX-XXX<br />

315<br />

421A-AOA-DM-DXXX-XXX<br />

315<br />

451A-AOA-DM-DXXX-XXX<br />

315<br />

461A-AOA-DM-DXXX-XXX<br />

315<br />

471A-AOA-DM-DXXX-XXX<br />

1/4” NPT<br />

411A-BOA-DM-DXXX-XXX<br />

421A-BOA-DM-DXXX-XXX<br />

451A-BOA-DM-DXXX-XXX<br />

461A-BOA-DM-DXXX-XXX<br />

471A-BOA-DM-DXXX-XXX<br />

1/8” NPT<br />

External<br />

411A-AOD-DM-DXXX-XXX<br />

421A-AOD-DM-DXXX-XXX<br />

451A-AOD-DM-DXXX-XXX<br />

461A-AOD-DM-DXXX-XXX<br />

471A-AOD-DM-DXXX-XXX<br />

1/4” NPT<br />

411A-BOD-DM-DXXX-XXX<br />

421A-BOD-DM-DXXX-XXX<br />

451A-BOD-DM-DXXX-XXX<br />

461A-BOD-DM-DXXX-XXX<br />

471A-BOD-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

JA 120/60, 110/50<br />

JC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

A<br />

J<br />

x<br />

18” (Flying leads)<br />

Connector<br />

Other Options<br />

1 Non-locking<br />

2 Locking<br />

x<br />

Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

CBM403A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard 19,5 mm<br />

w/o flow controls<br />

w/ flow controls<br />

Spacing 26 mm (Rectangular connector)<br />

w/o flow controls<br />

w/ flow controls<br />

3/8” NPTF<br />

Internal<br />

CBM403A-00AAA-XX<br />

CBM403A-00BAA-XX<br />

CBM403A-02AAA-XX<br />

CBM403A-02BAA-XX<br />

Common external<br />

CBM403A-00CAA-XX<br />

CBM403A-00DAA-XX<br />

CBM403A-02CAA-XX<br />

CBM403A-02DAA-XX<br />

Number of stations (03=3 stations)<br />

** Other options available. Consult factory.<br />

O P T I O N S<br />

411A-AOA-DM-DXXX-XXX<br />

- clic with memory spring (replace by 4).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum - 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.<br />

• Mounting screw (x2) : 35043.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

32,0<br />

125,0 DOUBLE (45)<br />

96,0 SINGLE (45)<br />

27,75<br />

5 1 3<br />

7,0<br />

C L<br />

4 2<br />

19,5<br />

69,5<br />

100,3<br />

C L<br />

4 2<br />

25,0<br />

5 1 3<br />

26,5<br />

21,0<br />

8,0<br />

15,0 20,5<br />

24,5<br />

38,0<br />

Ø 6,5<br />

3/8"<br />

67,5<br />

32,0<br />

41,0<br />

14,5<br />

1/8” EXTERNAL<br />

PILOT PORT<br />

(OPTIONAL)<br />

82,0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” - 1/4” 1.0C v<br />

add on style<br />

cylinder ports<br />

mid profile -<br />

in valve<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

1/8” NPT<br />

Internal<br />

315<br />

411A-AOA-DM-DXXX-XXX<br />

411A-COA-DM-DXXX-XXX<br />

315<br />

421A-AOA-DM-DXXX-XXX<br />

315<br />

451A-AOA-DM-DXXX-XXX<br />

315<br />

461A-AOA-DM-DXXX-XXX<br />

315<br />

471A-AOA-DM-DXXX-XXX<br />

1/4” NPT<br />

411A-BOA-DM-DXXX-XXX<br />

421A-BOA-DM-DXXX-XXX<br />

451A-BOA-DM-DXXX-XXX<br />

461A-BOA-DM-DXXX-XXX<br />

471A-BOA-DM-DXXX-XXX<br />

1/8” NPT<br />

External<br />

411A-AOD-DM-DXXX-XXX<br />

421A-AOD-DM-DXXX-XXX<br />

451A-AOD-DM-DXXX-XXX<br />

461A-AOD-DM-DXXX-XXX<br />

471A-AOD-DM-DXXX-XXX<br />

1/4” NPT<br />

411A-BOD-DM-DXXX-XXX<br />

421A-BOD-DM-DXXX-XXX<br />

451A-BOD-DM-DXXX-XXX<br />

461A-BOD-DM-DXXX-XXX<br />

471A-BOD-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

JA 120/60, 110/50<br />

JC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

A<br />

J<br />

x<br />

18” (Flying leads)<br />

Connector<br />

Other Options<br />

1 Non-locking<br />

2 Locking<br />

x<br />

Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

CBM403A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard 19,5 mm<br />

w/o flow controls<br />

w/ flow controls<br />

Spacing 26 mm (Rectangular connector)<br />

w/o flow controls<br />

w/ flow controls<br />

3/8” NPTF<br />

Internal<br />

CBM403A-00ABA-XX<br />

CBM403A-00BBA-XX<br />

CBM403A-02ABA-XX<br />

CBM403A-02BBA-XX<br />

Common external<br />

CBM403A-00CBA-XX<br />

CBM403A-00DBA-XX<br />

CBM403A-02CBA-XX<br />

CBM403A-02DBA-XX<br />

Number of stations (03=3 stations)<br />

** Other options available. Consult factory.<br />

Note: add-a-unit stations may be added to above bars.<br />

O P T I O N S<br />

411A-AOA-DM-DXXX-XXX<br />

- clic with memory spring (replace by 4).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


4<br />

2<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum - 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.<br />

• Mounting screw (x2) : 35043. • End plate kit : M-04003-01. • End plate kit for common external : M-04004-01.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

113.0 99.0<br />

100.3<br />

24.5<br />

Ø 6.5 TYP.<br />

21.0<br />

C L<br />

C L<br />

15.0<br />

7.0<br />

5 1 3<br />

14<br />

12<br />

14<br />

4 2<br />

12<br />

14<br />

4 2<br />

12<br />

14<br />

4 2<br />

12<br />

3<br />

1 5<br />

117.5 DOUBLE<br />

32.0<br />

82.0<br />

107.9 SINGLE<br />

18.0<br />

14.5<br />

32.0<br />

41.0<br />

67.5<br />

27.8<br />

1/8" EXTERNAL<br />

PILOT PORT<br />

25.0<br />

19.5<br />

6.5<br />

8.0<br />

OPTIONAL<br />

55.0<br />

40.5<br />

21.0<br />

16.0<br />

1/8" PORTS<br />

TYP. 8 PLACES<br />

3/8" PORTS<br />

TYP.<br />

20.5<br />

380<br />

C L<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” - 1/4” 1.0C v<br />

add-a-unit<br />

stations for<br />

CBM403A bar<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

1/8” NPT<br />

Internal<br />

315<br />

411A-AOA-DM-DXXX-XXX<br />

411A-COA-DM-DXXX-XXX<br />

315<br />

421A-AOA-DM-DXXX-XXX<br />

315<br />

451A-AOA-DM-DXXX-XXX<br />

315<br />

461A-AOA-DM-DXXX-XXX<br />

315<br />

471A-AOA-DM-DXXX-XXX<br />

1/4” NPT<br />

411A-BOA-DM-DXXX-XXX<br />

421A-BOA-DM-DXXX-XXX<br />

451A-BOA-DM-DXXX-XXX<br />

461A-BOA-DM-DXXX-XXX<br />

471A-BOA-DM-DXXX-XXX<br />

1/8” NPT<br />

External<br />

411A-AOD-DM-DXXX-XXX<br />

421A-AOD-DM-DXXX-XXX<br />

451A-AOD-DM-DXXX-XXX<br />

461A-AOD-DM-DXXX-XXX<br />

471A-AOD-DM-DXXX-XXX<br />

1/4” NPT<br />

411A-BOD-DM-DXXX-XXX<br />

421A-BOD-DM-DXXX-XXX<br />

451A-BOD-DM-DXXX-XXX<br />

461A-BOD-DM-DXXX-XXX<br />

471A-BOD-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

JA 120/60, 110/50<br />

JC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR **<br />

A<br />

J<br />

x<br />

18” (Flying leads)<br />

Connector<br />

Other Options<br />

1 Non-locking<br />

2 Locking<br />

x<br />

Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

CBM403A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing 21 mm<br />

w/o flow controls<br />

w/ flow controls<br />

Spacing 26 mm (Rectangular connector)<br />

w/o flow controls<br />

w/ flow controls<br />

3/8” NPTF<br />

Internal<br />

CBM403A-01AEA-XX<br />

CBM403A-01BEA-XX<br />

CBM403A-02AEA-XX<br />

CBM403A-02BEA-XX<br />

Common external<br />

CBM403A-01CEA-XX<br />

CBM403A-01DEA-XX<br />

CBM403A-02CEA-XX<br />

CBM403A-02DEA-XX<br />

Number of stations (01, 02, 03, or 04)<br />

** Other options available. Consult factory.<br />

O P T I O N S<br />

411A-AOA-DM-DXXX-XXX<br />

- clic with memory spring (replace by 4).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


4<br />

2<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum - 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.<br />

• Mounting screw (x2) : 35043. • End plate kit : M-04003-01. • End plate kit for common external : M-04004-01.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

113.0 99.0<br />

100.3<br />

24.5<br />

Ø 6.5 TYP.<br />

21.0<br />

C L<br />

C L<br />

15.0<br />

7.0<br />

5 1 3<br />

14<br />

12<br />

14<br />

4 2<br />

12<br />

14<br />

4 2<br />

12<br />

14<br />

4 2<br />

12<br />

3<br />

1 5<br />

117.5 DOUBLE<br />

32.0<br />

82.0<br />

107.9 SINGLE<br />

18.0<br />

14.5<br />

32.0<br />

41.0<br />

67.5<br />

27.8<br />

1/8" EXTERNAL<br />

PILOT PORT<br />

25.0<br />

19.5<br />

6.5<br />

8.0<br />

OPTIONAL<br />

55.0<br />

40.5<br />

21.0<br />

16.0<br />

1/8" PORTS<br />

TYP. 8 PLACES<br />

3/8" PORTS<br />

TYP.<br />

20.5<br />

380<br />

C L<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” - 1/4” 1.0C v<br />

mid profile<br />

cylinder ports<br />

in base<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

Internal<br />

315<br />

413A-OOA-DM-DXXX-XXX<br />

315<br />

423A-OOA-DM-DXXX-XXX<br />

315<br />

453A-OOA-DM-DXXX-XXX<br />

315<br />

463A-OOA-DM-DXXX-XXX<br />

315<br />

473A-OOA-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

A 18” (Flying leads)<br />

JA 120/60, 110/50<br />

J Connector<br />

JC 24/60, 24/50<br />

x Other Options<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) **<br />

1 Non-locking<br />

2 Locking<br />

x<br />

Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

CBM404A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard 19,5 mm<br />

w/o flow controls<br />

w/ flow controls<br />

Spacing 26 mm (Rectangular connector)<br />

w/o flow controls<br />

w/ flow controls<br />

1/8” NPTF<br />

1/4” NPTF<br />

Internal<br />

Internal<br />

CBM404A-00AAA-XX<br />

CBM404A-00AAD-XX<br />

CBM404A-00BAA-XX<br />

CBM404A-00BAD-XX<br />

CBM404A-02AAA-XX<br />

CBM404A-02AAD-XX<br />

CBM404A-02BAA-XX<br />

CBM404A-02BAD-XX<br />

Number of stations (03=3 stations)<br />

** Other options available. Consult factory.<br />

O P T I O N S<br />

413A-OOA-DM-DXXX-XXX<br />

- clic with memory spring (replace by 6).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Compressed air, vacuum, inert gases<br />

20 - 150 PSI<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.<br />

• Mounting screw (x2) : 35043.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

32,0<br />

125,0 DOUBLE (45)<br />

96,0 SINGLE (45)<br />

27,8<br />

100,3<br />

C L<br />

5 1 3<br />

4 2<br />

7,0<br />

C L<br />

4 2<br />

19,5<br />

69,5<br />

25,0<br />

5 1 3<br />

26,5<br />

21,0<br />

15,0 20,5<br />

24,5<br />

38,0<br />

3/8 " PORTS<br />

4 2<br />

14,5<br />

B A<br />

41,0<br />

67,5<br />

82,0<br />

Port size<br />

A<br />

B<br />

1/8”<br />

1/4”<br />

31.5<br />

32.0<br />

19.0<br />

20.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” - 1/4” 1.0C v<br />

add on style<br />

cylinder ports<br />

mid profile -<br />

in base<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

Internal<br />

315<br />

413A-OOA-DM-DXXX-XXX<br />

315<br />

423A-OOA-DM-DXXX-XXX<br />

315<br />

453A-OOA-DM-DXXX-XXX<br />

315<br />

463A-OOA-DM-DXXX-XXX<br />

315<br />

473A-OOA-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

A 18” (Flying leads)<br />

JA 120/60, 110/50<br />

J Connector<br />

JC 24/60, 24/50<br />

x Other Options<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) **<br />

1 Non-locking<br />

2 Locking<br />

x<br />

Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

CBM404A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard 19,5 mm<br />

w/o flow controls<br />

w/ flow controls<br />

Spacing 26 mm (Rectangular connector)<br />

w/o flow controls<br />

w/ flow controls<br />

1/8” NPTF<br />

1/4” NPTF<br />

Internal<br />

Internal<br />

CBM404A-00ABA-XX<br />

CBM404A-00ABD-XX<br />

CBM404A-00BBA-XX<br />

CBM404A-00BBD-XX<br />

CBM404A-02ABA-XX<br />

CBM404A-02ABD-XX<br />

CBM404A-02BBA-XX<br />

CBM404A-02BBD-XX<br />

Number of stations (03=3 stations)<br />

** Other options available. Consult factory.<br />

Note: add-a-unit stations may be added to above bars.<br />

O P T I O N S<br />

413A-OOA-DM-DXXX-XXX<br />

- clic with memory spring, replace by 6.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Compressed air, vacuum, inert gases<br />

20 - 150 PSI<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.<br />

• Mounting screw (x2) : 35043. • End plate kit : M-04003-01.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

113.0<br />

100.3<br />

É” 6.5 TYP.<br />

24.5<br />

21.0<br />

15.0<br />

5 1 3<br />

14<br />

12<br />

14<br />

12<br />

14<br />

12<br />

CL<br />

14<br />

12<br />

CL LC<br />

3<br />

1<br />

5<br />

82.0<br />

117.5 DOUBLE<br />

107.9 SINGLE<br />

14.5<br />

32.0<br />

41.0<br />

67.5<br />

99.0<br />

7.0<br />

25.0<br />

19.5<br />

6.5<br />

8.0<br />

1/8" EXTERNAL<br />

PILOT PORT<br />

OPTIONAL<br />

2<br />

2<br />

2<br />

2<br />

27.8<br />

31.5<br />

50.5<br />

40.5<br />

3/8" PORTS<br />

TYP.<br />

4<br />

4<br />

4<br />

4<br />

1/8" PORTS<br />

55.0 21.0<br />

16.0<br />

TYP. 8 PLACES<br />

20.5<br />

38.0<br />

42.0<br />

26.5<br />

C L<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” - 1/4” 1.0C v<br />

add-a-unit<br />

stations for<br />

CBM404A bar<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

Internal<br />

315<br />

413A-OOA-DM-DXXX-XXX<br />

315<br />

423A-OOA-DM-DXXX-XXX<br />

315<br />

453A-OOA-DM-DXXX-XXX<br />

315<br />

463A-OOA-DM-DXXX-XXX<br />

315<br />

473A-OOA-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

A 18” (Flying leads)<br />

JA 120/60, 110/50<br />

J Connector<br />

JC 24/60, 24/50<br />

x Other Options<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) **<br />

1 Non-locking<br />

2 Locking<br />

x<br />

Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

CBM404A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing 21 mm<br />

w/o flow controls<br />

w/ flow controls<br />

Spacing 26 mm (Rectangular connector)<br />

w/o flow controls<br />

w/ flow controls<br />

1/8” NPTF<br />

1/4” NPTF<br />

Internal<br />

Internal<br />

CBM404A-01AEA-XX<br />

CBM404A-01AED-XX<br />

CBM404A-01BEA-XX<br />

CBM404A-01BED-XX<br />

CBM404A-02AEA-XX<br />

CBM404A-02AED-XX<br />

CBM404A-02BEA-XX<br />

CBM404A-02BED-XX<br />

Number of stations (01, 02, 03, or 04)<br />

** Other options available. Consult factory.<br />

O P T I O N S<br />

413A-OOA-DM-DXXX-XXX<br />

- clic with memory spring (replace by 6).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Compressed air, vacuum, inert gases<br />

20 - 150 PSI<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.<br />

• Mounting screw (x2) : 35043. • End plate kit : M-04003-01.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

113.0<br />

100.3<br />

É” 6.5 TYP.<br />

24.5<br />

21.0<br />

15.0<br />

5 1 3<br />

14<br />

12<br />

14<br />

12<br />

14<br />

12<br />

CL<br />

14<br />

12<br />

CL LC<br />

3<br />

1<br />

5<br />

82.0<br />

117.5 DOUBLE<br />

107.9 SINGLE<br />

14.5<br />

32.0<br />

41.0<br />

67.5<br />

99.0<br />

7.0<br />

25.0<br />

19.5<br />

6.5<br />

8.0<br />

1/8" EXTERNAL<br />

PILOT PORT<br />

OPTIONAL<br />

2<br />

2<br />

2<br />

2<br />

27.8<br />

31.5<br />

50.5<br />

40.5<br />

3/8" PORTS<br />

TYP.<br />

4<br />

4<br />

4<br />

4<br />

1/8" PORTS<br />

55.0 21.0<br />

16.0<br />

TYP. 8 PLACES<br />

20.5<br />

38.0<br />

42.0<br />

26.5<br />

C L<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” - 1/4” 1.0C v<br />

high profile<br />

cylinder ports<br />

in base<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

Internal<br />

315<br />

413A-OOA-DM-DXXX-XXX<br />

315<br />

423A-OOA-DM-DXXX-XXX<br />

315<br />

453A-OOA-DM-DXXX-XXX<br />

315<br />

463A-OOA-DM-DXXX-XXX<br />

315<br />

473A-OOA-DM-DXXX-XXX<br />

External<br />

413A-OOD-DM-DXXX-XXX<br />

423A-OOD-DM-DXXX-XXX<br />

453A-OOD-DM-DXXX-XXX<br />

463A-OOD-DM-DXXX-XXX<br />

473A-OOD-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

A 18” (Flying leads)<br />

JA 120/60, 110/50<br />

J Connector<br />

JC 24/60, 24/50<br />

x Other Options<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR (SIDE CYLINDER PORTS) **<br />

1 Non-locking<br />

2 Locking<br />

x<br />

Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

CBM405A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard 19,5 mm<br />

Spacing 26 mm<br />

(Rectangular connector)<br />

1/8” NPTF<br />

1/4” NPTF<br />

Internal<br />

Common external<br />

Internal<br />

Common external<br />

CBM405A-00AAA-XX<br />

CBM405A-00BAA-XX<br />

CBM405A-00AAD-XX<br />

CBM405A-00BAD-XX<br />

CBM405A-02AAA-XX<br />

CBM405A-02BAA-XX<br />

CBM405A-02AAD-XX<br />

CBM405A-02BAD-XX<br />

Number of stations (03=3 stations)<br />

** Other options available. Consult factory.<br />

O P T I O N S<br />

413A-OOA-DM-DXXX-XXX<br />

- clic with memory spring (replace by 6).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum - 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04002. • Seal : 16525. • Mounting screw (x2) : 35043.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

5 1 3<br />

7,0<br />

C L<br />

4 2<br />

69,5<br />

4 2<br />

25,0<br />

19,5<br />

5 1 3<br />

59,0<br />

32,0<br />

125,0 DOUBLE (45)<br />

96,0 SINGLE (45)<br />

114,3<br />

2<br />

40,0<br />

33,5<br />

22,0<br />

52,0<br />

19,0<br />

4<br />

9,5<br />

3/8" PORTS<br />

1/8” EXTERNAL<br />

PILOT PORT<br />

(OPTIONAL)<br />

72,0<br />

46,0<br />

35,0<br />

20,0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” - 1/4” 1.0C v<br />

add on style<br />

cylinder ports<br />

high profile -<br />

in base<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

Internal<br />

315<br />

413A-OOA-DM-DXXX-XXX<br />

315<br />

423A-OOA-DM-DXXX-XXX<br />

315<br />

453A-OOA-DM-DXXX-XXX<br />

315<br />

463A-OOA-DM-DXXX-XXX<br />

315<br />

473A-OOA-DM-DXXX-XXX<br />

External<br />

413A-OOD-DM-DXXX-XXX<br />

423A-OOD-DM-DXXX-XXX<br />

453A-OOD-DM-DXXX-XXX<br />

463A-OOD-DM-DXXX-XXX<br />

473A-OOD-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

A 18” (Flying leads)<br />

JA 120/60, 110/50<br />

J Connector<br />

JC 24/60, 24/50<br />

x Other Options<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR (SIDE CYLINDER PORTS) **<br />

1 Non-locking<br />

2 Locking<br />

x<br />

Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

CBM405A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing st<strong>and</strong>ard 19,5 mm<br />

Spacing 26 mm<br />

(Rectangular connector)<br />

1/8” NPTF<br />

1/4” NPTF<br />

Internal<br />

Common external<br />

Internal<br />

Common external<br />

CBM405A-00ABA-XX<br />

CBM405A-00BCA-XX<br />

CBM405A-00ABD-XX<br />

CBM405A-00BCD-XX<br />

CBM405A-02ABA-XX<br />

CBM405A-02BCA-XX<br />

CBM405A-02ABD-XX<br />

CBM405A-02BCD-XX<br />

Number of stations (03=3 stations)<br />

** Other options available. Consult factory.<br />

Note: add-a-unit stations may be added to above bars.<br />

O P T I O N S<br />

413A-OOA-DM-DXXX-XXX<br />

- clic with memory spring (replace by 6).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum - 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04002. • Seal : 16525. • Mounting screw (x2) : 35043.<br />

• End plate kit : M-04005-01. • End plate kit for common external pilot : M-04006-01.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

113.0<br />

114.3<br />

40.0<br />

33.5<br />

19.0<br />

84.0<br />

5 1 3<br />

12<br />

14<br />

12<br />

14<br />

12<br />

14 14<br />

12<br />

3<br />

1<br />

5<br />

118.0 DOUBLE<br />

98.5 SINGLE<br />

20.0<br />

35.0<br />

46.0<br />

72.0<br />

99.0<br />

7.0<br />

1/8" EXTERNAL<br />

PILOT PORT<br />

21.0<br />

21.0<br />

3/8" PORTS<br />

TYP.<br />

OPTIONAL<br />

59.0<br />

10.5<br />

16.0<br />

55.0<br />

9.5<br />

Ø 6.50<br />

TYP 2<br />

16.0<br />

4<br />

2<br />

52.0<br />

20.0<br />

21.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 400<br />

Function Port size (NPTF) Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/8” - 1/4” 1.0C v<br />

add-a-unit<br />

stations for<br />

CBM405A bar<br />

OPERATIONAL BENEFITS<br />

1. The 4-way pilot develops maximum shifting forces<br />

both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of pressure,<br />

also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short <strong>and</strong><br />

consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-xxx-DM-Dxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Pilot air<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

2 4<br />

12 14<br />

2 4<br />

12 14<br />

12 2 4 14<br />

12 2 4 14<br />

12 2 4 14<br />

Internal<br />

315<br />

413A-OOA-DM-DXXX-XXX<br />

315<br />

423A-OOA-DM-DXXX-XXX<br />

315<br />

453A-OOA-DM-DXXX-XXX<br />

315<br />

463A-OOA-DM-DXXX-XXX<br />

315<br />

473A-OOA-DM-DXXX-XXX<br />

External<br />

413A-OOD-DM-DXXX-XXX<br />

423A-OOD-DM-DXXX-XXX<br />

453A-OOD-DM-DXXX-XXX<br />

463A-OOD-DM-DXXX-XXX<br />

473A-OOD-DM-DXXX-XXX<br />

SOLENOID OPERATOR ➤<br />

D XX X- X XX *<br />

XX Voltage<br />

X Wire length<br />

X Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

A 18” (Flying leads)<br />

JA 120/60, 110/50<br />

J Connector<br />

JC 24/60, 24/50<br />

x Other Options<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR (SIDE CYLINDER PORTS) **<br />

1 Non-locking<br />

2 Locking<br />

x<br />

Other Options<br />

KA<br />

KD<br />

JB<br />

JD<br />

BA<br />

xx<br />

Square connector<br />

Square connector<br />

with light<br />

Rectangular connector<br />

Rectangular connector<br />

with light<br />

Flying leads<br />

Other Options<br />

CBM405A-xxxxx-xx<br />

Port size<br />

Pilot air<br />

Spacing 21 mm<br />

Spacing 26 mm<br />

(Rectangular connector)<br />

1/8” NPTF<br />

1/4” NPTF<br />

Internal<br />

Common external<br />

Internal<br />

Common external<br />

CBM405A-01AEA-XX<br />

CBM405A-01BEA-XX<br />

CBM405A-01AED-XX<br />

CBM405A-01BED-XX<br />

CBM405A-02AEA-XX<br />

CBM405A-02BEA-XX<br />

CBM405A-02AED-XX<br />

CBM405A-02BED-XX<br />

Number of stations (01, 02, 03, or 04)<br />

** Other options available. Consult factory.<br />

O P T I O N S<br />

413A-OOA-DM-DXXX-XXX<br />

- clic with memory spring (replace by 6).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 400<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Accessories :<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 - 150 PSI<br />

External pilot : vacuum - 150 PSI<br />

20 - 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 10.9 VA Holding : 7.7 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms<br />

60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms<br />

• Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 <strong>and</strong> seal 16524.<br />

• Blanking plate : M-04002. • Seal : 16525. • Mounting screw (x2) : 35043.<br />

• End plate kit : M-04005-01. • End plate kit for common external pilot : M-04006-01.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust.<br />

DIMENSIONS<br />

113.0<br />

114.3<br />

40.0<br />

33.5<br />

19.0<br />

84.0<br />

5 1 3<br />

12<br />

14<br />

12<br />

14<br />

12<br />

14 14<br />

12<br />

3<br />

1<br />

5<br />

118.0 DOUBLE<br />

98.5 SINGLE<br />

20.0<br />

35.0<br />

46.0<br />

72.0<br />

99.0<br />

7.0<br />

1/8" EXTERNAL<br />

PILOT PORT<br />

21.0<br />

21.0<br />

3/8" PORTS<br />

TYP.<br />

OPTIONAL<br />

59.0<br />

10.5<br />

16.0<br />

55.0<br />

9.5<br />

Ø 6.50<br />

TYP 2<br />

16.0<br />

4<br />

2<br />

52.0<br />

20.0<br />

21.0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Section 2 Options<br />

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Codification table for voltages / Wire length / Manual operator / Electrical connection<br />

VALVE CODE ➤<br />

D M - D XX X - X XX<br />

1 2 3 4<br />

OPTIONS AVAILABLE FOR<br />

- pilot operated valves 400, 52 & 92 Series<br />

Consult “Precautions”before use, installation or service of MAC Valves.


OPTIONS<br />

Back<br />

1. VOLTAGE<br />

- D XX X - X XX VOLTAGE<br />

DB 12 VDC (5.4 W)<br />

DC 12 VDC (7.5 W)<br />

DD 24 VDC (7.3 W)<br />

DE 12 VDC (12.7 W)<br />

DK 110 VDC (5.8 W)<br />

DJ 28 VDC (5.7 W)<br />

DL 64 VDC (6.0 W)<br />

DM 36 VDC (5.8 W)<br />

DN 6 VDC (6.0 W)<br />

DR 90 VDC (6,6 W)<br />

DS 110 VDC (7.3 W), 100 VDC (6.0 W)<br />

DT 75 VDC (5.6 W)<br />

DP 48 VDC (5.8 W)<br />

FA 12 VDC (1.8 W)<br />

FE 12 VDC (2.4 W)<br />

FF 24 VDC (2.4 W)<br />

JD 100/60, 100/50, 110/60<br />

2. WIRE LENGTH<br />

- D XX X - X XX WIRE LENGTH<br />

B 24”<br />

C 36”<br />

D 48”<br />

E 72”<br />

F 96”<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Back<br />

3. MANUAL OPERATOR<br />

- D XX X - X XX MANUAL OPERATOR<br />

0 No operator<br />

1 Non-locking recessed<br />

2 Locking recessed<br />

3 Non-locking extended<br />

4 Locking extended<br />

4. ELECTRICAL CONNECTION<br />

- D XX X - X XX ELECTRICAL CONNECTION<br />

BA Flying leads<br />

BK BA with protection diode<br />

BL BA with protection varistor<br />

CA 1/2" NPS conduit<br />

JB Rectangular connector<br />

JD Rectangular connector with light<br />

JM Rectangular connector, male only<br />

KA Square connector<br />

KB Square connector with protection diode<br />

KC Square connector with protection varistor<br />

KD Square connector with light<br />

KE Square connector with light <strong>and</strong> protection diode<br />

KF Square connector with light <strong>and</strong> protection varistor<br />

KJ Square connector (male only)<br />

KK Square connector with protection diode (male only)<br />

KL Square connector with protection varistor (male only)<br />

TA Dual tabs<br />

TB TA with protection diode<br />

TD TA with light<br />

TE TA with light <strong>and</strong> protection diode<br />

TJ Dual tabs (male only)<br />

TK TJ with protection diode<br />

TM TJ with light<br />

TN TJ with light <strong>and</strong> protection diode<br />

*DN Plug-in with diode<br />

*DP Plug-in with M.O.V.<br />

*DH Plug-in with diode & ground<br />

*DJ Plug-in with M.O.V & ground<br />

* These options only apply to the 92 series. All others are for the 400 <strong>and</strong> 52 series.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

PIN #6<br />

PIN #9<br />

MOD. SD09<br />

PIN #1<br />

PIN #5<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 9<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 7 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 2 common wires<br />

PIN #9<br />

PIN #15<br />

MOD. SD15<br />

PIN #1<br />

PIN #8<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 15<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 12 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 3 common wires<br />

PIN #14<br />

PIN #25<br />

MOD. SD25<br />

PIN #1<br />

PIN #13<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 25<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 20 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 5 common wires<br />

Note : Use desired MOD. number after circuit bar part number


O p t i o n s<br />

OPTIONS<br />

Connector termination details<br />

CONNECTOR<br />

SOL 1<br />

SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />

Single solenoid circuit bar<br />

SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />

CONNECTOR<br />

SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />

Double solenoid circuit bar<br />

SD09 SD15 SD25<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

8<br />

COMMON (+)<br />

13<br />

COMMON (+)<br />

21<br />

COMMON (+)<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

9<br />

COMMON (+)<br />

8<br />

SOL. 8<br />

8<br />

SOL. 8<br />

14<br />

COMMON (+)<br />

22<br />

COMMON (+)<br />

9<br />

SOL. 9<br />

9<br />

SOL. 9<br />

10 SOL. 10<br />

10 SOL. 10<br />

11<br />

SOL. 11<br />

11<br />

SOL. 11<br />

12 SOL. 12<br />

12 SOL. 12<br />

15<br />

COMMON (+)<br />

23<br />

COMMON (+)<br />

13<br />

SOL. 13<br />

14 SOL. 14<br />

15<br />

SOL. 15<br />

16 SOL. 16<br />

24<br />

COMMON (+)<br />

17<br />

18 SOL. 18<br />

19<br />

20 SOL. 20<br />

SOL. 17<br />

SOL. 19<br />

25<br />

COMMON (+)


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 92<br />

Circuit bar mounting<br />

st<strong>and</strong>ard<br />

add-on style<br />

add-a-unit<br />

stations<br />

for CBM092B<br />

Optional light<br />

Plug-in solenoid<br />

Manual operator<br />

Solenoid<br />

Bonded spool<br />

Air return<br />

EXH.<br />

B<br />

IN.<br />

A<br />

EXH.<br />

EXH.<br />

IN.<br />

4-way pilot with balanced poppet<br />

SERIES FEATURES<br />

• Patented MACSOLENOID ® for fastest possible response times<br />

<strong>and</strong> virtually burn-out proof AC solenoid operation.<br />

• Optional low watt DC solenoids.<br />

• Optional memory spring.<br />

• Plug-in design of valves <strong>and</strong> bases for ease of maintenance.<br />

• 2 position or 3 position valve configurations.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves with multi-pin connector<br />

Series 92<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 - 3/2 1/8 - 1/4 - 3/8 1.0C v st<strong>and</strong>ard<br />

OPERATIONAL BENEFITS<br />

1. The 4--way pilot develops maximum shifting<br />

forces both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of<br />

pressure, also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded seal spool with minimum friction,<br />

shifting in a glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short<br />

<strong>and</strong> consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

SINGLE PRESSURE MODELS<br />

92B-xxx-000-DM-DxxP-xxx<br />

Port size<br />

(see circuit bar)<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

Valve less base<br />

92B-AAA-000-DM-DXXP-XXX<br />

92B-BAA-000-DM-DXXP-XXX<br />

92B-EAA-000-DM-DXXP-XXX<br />

92B-FAA-000-DM-DXXP-XXX<br />

92B-GAA-000-DM-DXXP-XXX<br />

DUAL PRESSURE MODELS (REQUIRES SANDWICH PRESSURE REGULATOR)<br />

Port size<br />

(see circuit bar)<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

Valve less base<br />

92B-CAA-000-DM-DXXP-XXX<br />

92B-DAA-000-DM-DXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

DM-DXX P- X XX *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

JA 120/60, 110/50<br />

JC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

1 Non-locking<br />

2 Locking<br />

xx Other Options<br />

DM<br />

DG<br />

Plug-in<br />

Plug-in w/ground<br />

Note : Ground wire required for solenoids 30 volts<br />

<strong>and</strong> above.<br />

xx Other Options<br />

CBM092B-01xxx-AOxx<br />

Port size<br />

Pilot air<br />

Side cylinder ports<br />

(25 mm)<br />

Bottom cylinder ports<br />

(25 mm)<br />

1/8 NPTF<br />

Internal<br />

CBM092B-01AAA-A0*XX<br />

CBM092B-01BAA-A0*XX<br />

Common external<br />

CBM092B-01CAA-A0*XX<br />

CBM092B-01DAA-A0*XX<br />

1/4 NPTF<br />

Internal<br />

CBM092B-01AAD-A0*XX<br />

CBM092B-01BAD-A0*XX<br />

Common external<br />

CBM092B-01CAD-A0*XX<br />

CBM092B-01DAD-A0*XX<br />

3/8 NPTF<br />

Internal<br />

CBM092B-01AAG-A0*XX<br />

CBM092B-01BAG-A0*XX<br />

Common external<br />

CBM092B-01CAG-A0*XX<br />

CBM092B-01DAG-A0*XX<br />

Number of stations (03=3 stations)<br />

* If replaced by BO : circuit bar for single operator valves only.<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

for multi-pin connector (9, 15 or 25).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 92<br />

O P T I O N S<br />

S<strong>and</strong>wich flow controls available, consult factory.<br />

92B-AAA-000-DM-DXXP-1DM<br />

T E C H N I C A L<br />

D A T A<br />

For lights on valve, replace by B.<br />

For lights <strong>and</strong> diode on valve, replace by F.<br />

For lights <strong>and</strong> MOV on valve, replace by H.<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 to 120 PSI<br />

3 positions : 35 to 120 PSI<br />

External pilot : vacuum to 120 PSI<br />

3 positions : 35 to 120 PSI<br />

20 to 120 PSI 3 positions : 35 to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 7.6 VA Holding : 4.8 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 8 ms De-energize : 7 ms<br />

60Hz/2.9 W Energize : 7-13 ms De-energize : 12-20 ms<br />

• Pilot valve : DMB-DXXP-XXX-1 including mounting screws 35069 (x2) <strong>and</strong> seal 16544.<br />

• Pressure seal between valve <strong>and</strong> base : 16543. • Mounting screws valve to base (x2) : 35050. • Blanking plate : M-92002.<br />

Options :<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust. • Circuit bar for number of stations > 24.<br />

DIMENSIONS<br />

C<br />

34.0 D<br />

118.7<br />

B 25.0<br />

TYP.<br />

A 25.0<br />

18.4<br />

TYP.<br />

B B B EXT.P<br />

A A A<br />

A<br />

B<br />

1/8",1/4",3/8",PORTS<br />

AVAILABE ON SIDE<br />

OR BOTTOM<br />

164.3<br />

APROX.<br />

W/DOUBLE<br />

SIOLENOID<br />

148.3<br />

APROX.<br />

W/ SINGLE<br />

SOLENOID<br />

MODEL<br />

A<br />

B<br />

MODEL<br />

A<br />

B<br />

MODEL<br />

A<br />

B<br />

MODEL<br />

A<br />

7.0<br />

TYP.<br />

B<br />

5.5<br />

TYP.<br />

81.5<br />

TYP.<br />

1/8" PORTS EXTERNAL<br />

PILOT PORT 3 PLACES<br />

52.0<br />

42.0<br />

36.5<br />

25.5<br />

21.5<br />

EXT.P<br />

EA<br />

IN<br />

EB<br />

25.5<br />

3/8" PORTS<br />

3 PLACES<br />

BOTH ENDS<br />

27.0<br />

51.2<br />

73.1<br />

115.5<br />

B<br />

COND.<br />

25.0 G<br />

TYP.<br />

1 1/4" N.P.S.M.<br />

CONDUIT BOTH<br />

ENDS<br />

25.6<br />

6.3 DIA. MT'G<br />

HOLES 4 PLACES<br />

B<br />

A<br />

B<br />

A<br />

A<br />

B<br />

A<br />

B<br />

40.4<br />

F<br />

Number of<br />

stations<br />

“H”<br />

1<br />

60.0<br />

2<br />

85.0<br />

3<br />

4<br />

5<br />

6<br />

110.0 135.0 160.0 185.0 210.0 235.0 260.0 285.0<br />

7<br />

8<br />

9<br />

10<br />

Dim.<br />

“A”<br />

“B”<br />

“C”<br />

“D”<br />

1/8”<br />

30.0<br />

39.0<br />

10.0<br />

33.0<br />

1/4”<br />

30.0<br />

39.0<br />

10.0<br />

33.0<br />

3/8”<br />

32.5<br />

36.5<br />

11.0<br />

34.0<br />

25.0 E<br />

TYP.<br />

H<br />

Dimensions are based on 25 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

“E”<br />

“F”<br />

“G”<br />

40.9<br />

61.1<br />

30.1<br />

36.9<br />

61.1<br />

30.9<br />

35.5<br />

62.6<br />

30.7<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves with multi-pin connector<br />

Series 92<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 - 3/2 1/8 - 1/4 - 3/8 1.0C v add-on style<br />

OPERATIONAL BENEFITS<br />

1. The 4--way pilot develops maximum shifting<br />

forces both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of<br />

pressure, also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded seal spool with minimum friction,<br />

shifting in a glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short<br />

<strong>and</strong> consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

SINGLE PRESSURE MODELS<br />

92B-xxx-000-DM-DxxP-xxx<br />

Port size<br />

(see circuit bar)<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

Valve less base<br />

92B-AAA-000-DM-DXXP-XXX<br />

92B-BAA-000-DM-DXXP-XXX<br />

92B-EAA-000-DM-DXXP-XXX<br />

92B-FAA-000-DM-DXXP-XXX<br />

92B-GAA-000-DM-DXXP-XXX<br />

DUAL PRESSURE MODELS (REQUIRES SANDWICH PRESSURE REGULATOR)<br />

Port size<br />

(see circuit bar)<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

Valve less base<br />

92B-CAA-000-DM-DXXP-XXX<br />

92B-DAA-000-DM-DXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

DM-DXX P- X XX *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

JA 120/60, 110/50<br />

JC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

1 Non-locking<br />

2 Locking<br />

xx Other Options<br />

DM<br />

DG<br />

Plug-in<br />

Plug-in w/ground<br />

Note : Ground wire required for solenoids 30 volts<br />

<strong>and</strong> above.<br />

xx Other Options<br />

CBM092B-01xxx-AOxx<br />

Port size<br />

Pilot air<br />

Side cylinder ports<br />

(25 mm)<br />

Bottom cylinder ports<br />

(25 mm)<br />

1/8 NPTF<br />

Internal<br />

CBM092B-01ABA-A0*XX<br />

CBM092B-01BBA-A0*XX<br />

Common external<br />

CBM092B-01CBA-A0*XX<br />

CBM092B-01DBA-A0*XX<br />

1/4 NPTF<br />

Internal<br />

CBM092B-01ABD-A0*XX<br />

CBM092B-01BBD-A0*XX<br />

Common external<br />

CBM092B-01CBD-A0*XX<br />

CBM092B-01DBD-A0*XX<br />

3/8 NPTF<br />

Internal<br />

CBM092B-01ABG-A0*XX<br />

CBM092B-01BBG-A0*XX<br />

Common external<br />

CBM092B-01CBG-A0*XX<br />

CBM092B-01DBG-A0*XX<br />

* If replaced by BO : circuit bar for single operator valves only.<br />

Number of stations (03=3 stations)<br />

Note : add-a-unit stations may be added to above bars. See<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

page for model numbers<br />

for multi-pin connector (9, 15 or 25).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

GAGE<br />

EA<br />

IN<br />

EB<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 92<br />

O P T I O N S<br />

S<strong>and</strong>wich flow controls available, consult factory.<br />

92B-AAA-000-DM-DXXP-1DM<br />

For lights on valve, replace by B.<br />

For lights <strong>and</strong> diode on valve, replace by F.<br />

For lights <strong>and</strong> MOV on valve, replace by H.<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Options :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 to 120 PSI<br />

3 positions : 35 to 120 PSI<br />

External pilot : vacuum to 120 PSI<br />

3 positions : 35 to 120 PSI<br />

20 to 120 PSI 3 positions : 35 to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 7.6 VA Holding : 4.8 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 8 ms De-energize : 7 ms<br />

60Hz/2.9 W Energize : 7-13 ms De-energize : 12-20 ms<br />

• Pilot valve : DMB-DXXP-XXX-1 including mounting screws 35069 (x2) <strong>and</strong> seal 16544.<br />

• Pressure seal between valve <strong>and</strong> base : 16543. • Mounting screws valve to base (x2) : 35050. • Blanking plate : M-92002.<br />

• End plate kit : M-92001-01 • Isolator disc between add-a-units : 28413.<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust. • Circuit bar for number of stations > 24.<br />

DIMENSIONS<br />

EA<br />

EB IN<br />

164.0<br />

APPROX.<br />

W/SINGLE<br />

REGULATOR<br />

192.3<br />

APPROX.<br />

SINGLE REG.<br />

W/ DOUBLE<br />

REGULATOR<br />

241.0<br />

APPROX.<br />

W/DOUBLE<br />

REGULATOR<br />

34.0<br />

137.0 118.7<br />

APPROX.<br />

W/ FLOW<br />

CONTROLS<br />

D<br />

B<br />

A<br />

18.4<br />

C<br />

A<br />

EXT.P<br />

25.0<br />

TYP.<br />

25.0<br />

TYP.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

15.0<br />

B<br />

60.5<br />

APPROX.<br />

FROM C L OF<br />

FLOW CONTROL<br />

1/8",1/4",3/8",<br />

PORTS AVAILABE ON<br />

SIDE OR BOTTOM<br />

70.0<br />

APPROX.<br />

FROM C L OF<br />

REGULATOR<br />

Number of<br />

stations<br />

“H”<br />

1<br />

63.0<br />

2<br />

3<br />

Dimensions are based on 25 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

4<br />

5<br />

6<br />

88.0 113.0 138.0 163.0 188.0 213.0 238.0 263.0 288.0<br />

7<br />

8<br />

9<br />

10<br />

MODEL<br />

157.5<br />

APPROX.<br />

W/ REGULATOR<br />

25.0<br />

7.0<br />

TYP.<br />

E<br />

G<br />

25.0<br />

TYP.<br />

25.0<br />

TYP.<br />

1/8" EXTERNAL PILOT<br />

PORT 3 PLACES<br />

52.0<br />

42.0<br />

36.5<br />

25.5<br />

21.5<br />

27.0<br />

162.6<br />

APPROX.<br />

W/DOUBLE<br />

SOLENOID<br />

148.3<br />

APPROX.<br />

W/ SINGLE<br />

SOLENOID<br />

5.5<br />

TYP.<br />

81.5<br />

TYP.<br />

F<br />

40.4<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

MODIF.<br />

EXT.P<br />

COND<br />

25.5<br />

51.2<br />

73.1<br />

3/8" PORTS<br />

3 HOLES<br />

BOTH ENDS<br />

115.5<br />

Dim.<br />

“A”<br />

“B”<br />

“C”<br />

“D”<br />

1/8”<br />

32.0<br />

39.0<br />

10.0<br />

33.4<br />

1/4”<br />

32.0<br />

39.0<br />

10.0<br />

33.4<br />

3/8”<br />

34.5<br />

36.5<br />

11.0<br />

33.0<br />

6.3 DIA.MT'G<br />

HOLE 4 PLACES<br />

73.0<br />

2-STATION<br />

ADD-ON BAR<br />

H<br />

25.0<br />

TYP.<br />

ADD<br />

A-UNIT<br />

25.6<br />

1 1/4" N.P.S.M.<br />

CONDUIT BOTH<br />

ENDS<br />

“E”<br />

“F”<br />

“G”<br />

40.9<br />

61.1<br />

30.1<br />

37.9<br />

61.1<br />

31.9<br />

36.5<br />

62.6<br />

34.5<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves with multi-pin connector<br />

Series 92<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 - 3/2 1/8 - 1/4 - 3/8 1.0C v<br />

add-a-unit<br />

stations<br />

for CBM092B<br />

OPERATIONAL BENEFITS<br />

1. The 4--way pilot develops maximum shifting<br />

forces both ways.<br />

2. Memory spring available.<br />

3. Balanced spool, immune to variations of<br />

pressure, also provides high flow.<br />

4. Short stroke with high flow.<br />

5. Bonded seal spool with minimum friction,<br />

shifting in a glass-like finished bore.<br />

6. Pilot with balanced poppet, high flow, short<br />

<strong>and</strong> consistent response times.<br />

7. Wiping effect eliminates sticking.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

SINGLE PRESSURE MODELS<br />

92B-xxx-000-DM-DxxP-xxx<br />

Port size<br />

(see circuit bar)<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

Valve less base<br />

92B-AAA-000-DM-DXXP-XXX<br />

92B-BAA-000-DM-DXXP-XXX<br />

92B-EAA-000-DM-DXXP-XXX<br />

92B-FAA-000-DM-DXXP-XXX<br />

92B-GAA-000-DM-DXXP-XXX<br />

DUAL PRESSURE MODELS (REQUIRES SANDWICH PRESSURE REGULATOR)<br />

Port size<br />

(see circuit bar)<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

Valve less base<br />

92B-CAA-000-DM-DXXP-XXX<br />

92B-DAA-000-DM-DXXP-XXX<br />

SOLENOID OPERATOR ➤<br />

DM-DXX P- X XX *<br />

XX<br />

Voltage<br />

X<br />

Manual operator<br />

XX<br />

Electrical connection<br />

JB 240/60, 220/50<br />

JA 120/60, 110/50<br />

JC 24/60, 24/50<br />

FB 24VDC (1.8 W)<br />

DA 24VDC (5.4 W)<br />

DF 24VDC (12.7 W)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR<br />

Port size<br />

1/8 NPTF<br />

1/4 NPTF<br />

3/8 NPTF<br />

1 Non-locking<br />

2 Locking<br />

xx Other Options<br />

Side cylinder ports<br />

(25 mm)<br />

CBM092B-01ACA-A0*XX<br />

CBM092B-01ACD-A0*XX<br />

CBM092B-01ACG-A0*XX<br />

DM<br />

DG<br />

Plug-in<br />

Plug-in w/ground<br />

Note : Ground wire required for solenoids 30 volts<br />

<strong>and</strong> above.<br />

xx Other Options<br />

CBM092B-01xxx-AOxx<br />

Bottom cylinder ports<br />

(25 mm)<br />

CBM092B-01BCA-A0*XX<br />

CBM092B-01BCD-A0*XX<br />

CBM092B-01BCG-A0*XX<br />

Number of stations (01=1 stations). Available in one (1) or two (2) station lenghts.<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

when add-a-units are added to bars with a multi-pin connector, MOD SD03 should be<br />

included with add-a-unit model number.<br />

* If replaced by BO : circuit bar for single operator valves only.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

GAGE<br />

EA<br />

IN<br />

EB<br />

100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 92<br />

O P T I O N S<br />

S<strong>and</strong>wich flow controls available, consult factory.<br />

92B-AAA-000-DM-DXXP-1DM<br />

T E C H N I C A L<br />

D A T A<br />

For lights on valve, replace by B.<br />

For lights <strong>and</strong> diode on valve, replace by F.<br />

For lights <strong>and</strong> MOV on valve, replace by H.<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : 20 to 120 PSI<br />

3 positions : 35 to 120 PSI<br />

External pilot : vacuum to 120 PSI<br />

3 positions : 35 to 120 PSI<br />

20 to 120 PSI 3 positions : 35 to 120 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

6.2 mm<br />

1.0 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 7.6 VA Holding : 4.8 VA<br />

= 1.8 to 12.7 W<br />

24 V=/5.4 W Energize : 8 ms De-energize : 7 ms<br />

60Hz/2.9 W Energize : 7-13 ms De-energize : 12-20 ms<br />

• Pilot valve : DMB-DXXP-XXX-1 including mounting screws 35069 (x2) <strong>and</strong> seal 16544.<br />

• Pressure seal between valve <strong>and</strong> base : 16543. • Mounting screws valve to base (x2) : 35050. • Blanking plate : M-92002.<br />

Options :<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust. • Circuit bar for number of stations > 24.<br />

DIMENSIONS<br />

EA<br />

EB IN<br />

164.0<br />

APPROX.<br />

W/SINGLE<br />

REGULATOR<br />

192.3<br />

APPROX.<br />

SINGLE REG.<br />

W/ DOUBLE<br />

REGULATOR<br />

241.0<br />

APPROX.<br />

W/DOUBLE<br />

REGULATOR<br />

34.0<br />

137.0 118.7<br />

APPROX.<br />

W/ FLOW<br />

CONTROLS<br />

D<br />

B<br />

A<br />

18.4<br />

C<br />

A<br />

EXT.P<br />

25.0<br />

TYP.<br />

25.0<br />

TYP.<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

15.0<br />

B<br />

60.5<br />

APPROX.<br />

FROM C L OF<br />

FLOW CONTROL<br />

1/8",1/4",3/8",<br />

PORTS AVAILABE ON<br />

SIDE OR BOTTOM<br />

70.0<br />

APPROX.<br />

FROM C L OF<br />

REGULATOR<br />

Number of<br />

stations<br />

“H”<br />

1<br />

63.0<br />

2<br />

3<br />

Dimensions are based on 25 mm centerline spacing<br />

Note: Bottom & side cylinder ports not available on the same station<br />

4<br />

5<br />

6<br />

88.0 113.0 138.0 163.0 188.0 213.0 238.0 263.0 288.0<br />

7<br />

8<br />

9<br />

10<br />

MODEL<br />

157.5<br />

APPROX.<br />

W/ REGULATOR<br />

25.0<br />

7.0<br />

TYP.<br />

E<br />

G<br />

25.0<br />

TYP.<br />

25.0<br />

TYP.<br />

1/8" EXTERNAL PILOT<br />

PORT 3 PLACES<br />

52.0<br />

42.0<br />

36.5<br />

25.5<br />

21.5<br />

27.0<br />

162.6<br />

APPROX.<br />

W/DOUBLE<br />

SOLENOID<br />

148.3<br />

APPROX.<br />

W/ SINGLE<br />

SOLENOID<br />

5.5<br />

TYP.<br />

81.5<br />

TYP.<br />

F<br />

40.4<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

MODIF.<br />

EXT.P<br />

COND<br />

25.5<br />

51.2<br />

73.1<br />

3/8" PORTS<br />

3 HOLES<br />

BOTH ENDS<br />

115.5<br />

Dim.<br />

“A”<br />

“B”<br />

“C”<br />

“D”<br />

1/8”<br />

32.0<br />

39.0<br />

10.0<br />

33.4<br />

1/4”<br />

32.0<br />

39.0<br />

10.0<br />

33.4<br />

3/8”<br />

34.5<br />

36.5<br />

11.0<br />

33.0<br />

6.3 DIA.MT'G<br />

HOLE 4 PLACES<br />

73.0<br />

2-STATION<br />

ADD-ON BAR<br />

H<br />

25.0<br />

TYP.<br />

ADD<br />

A-UNIT<br />

25.6<br />

1 1/4" N.P.S.M.<br />

CONDUIT BOTH<br />

ENDS<br />

“E”<br />

“F”<br />

“G”<br />

40.9<br />

61.1<br />

30.1<br />

37.9<br />

61.1<br />

31.9<br />

36.5<br />

62.6<br />

34.5<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Section 2 Options<br />

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Codification table for voltages / Wire length / Manual operator / Electrical connection<br />

VALVE CODE ➤<br />

D M - D XX X - X XX<br />

1 2 3 4<br />

OPTIONS AVAILABLE FOR<br />

- pilot operated valves 400, 52 & 92 Series<br />

Consult “Precautions”before use, installation or service of MAC Valves.


OPTIONS<br />

Back<br />

1. VOLTAGE<br />

- D XX X - X XX VOLTAGE<br />

DB 12 VDC (5.4 W)<br />

DC 12 VDC (7.5 W)<br />

DD 24 VDC (7.3 W)<br />

DE 12 VDC (12.7 W)<br />

DK 110 VDC (5.8 W)<br />

DJ 28 VDC (5.7 W)<br />

DL 64 VDC (6.0 W)<br />

DM 36 VDC (5.8 W)<br />

DN 6 VDC (6.0 W)<br />

DR 90 VDC (6,6 W)<br />

DS 110 VDC (7.3 W), 100 VDC (6.0 W)<br />

DT 75 VDC (5.6 W)<br />

DP 48 VDC (5.8 W)<br />

FA 12 VDC (1.8 W)<br />

FE 12 VDC (2.4 W)<br />

FF 24 VDC (2.4 W)<br />

JD 100/60, 100/50, 110/60<br />

2. WIRE LENGTH<br />

- D XX X - X XX WIRE LENGTH<br />

B 24”<br />

C 36”<br />

D 48”<br />

E 72”<br />

F 96”<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Back<br />

3. MANUAL OPERATOR<br />

- D XX X - X XX MANUAL OPERATOR<br />

0 No operator<br />

1 Non-locking recessed<br />

2 Locking recessed<br />

3 Non-locking extended<br />

4 Locking extended<br />

4. ELECTRICAL CONNECTION<br />

- D XX X - X XX ELECTRICAL CONNECTION<br />

BA Flying leads<br />

BK BA with protection diode<br />

BL BA with protection varistor<br />

CA 1/2" NPS conduit<br />

JB Rectangular connector<br />

JD Rectangular connector with light<br />

JM Rectangular connector, male only<br />

KA Square connector<br />

KB Square connector with protection diode<br />

KC Square connector with protection varistor<br />

KD Square connector with light<br />

KE Square connector with light <strong>and</strong> protection diode<br />

KF Square connector with light <strong>and</strong> protection varistor<br />

KJ Square connector (male only)<br />

KK Square connector with protection diode (male only)<br />

KL Square connector with protection varistor (male only)<br />

TA Dual tabs<br />

TB TA with protection diode<br />

TD TA with light<br />

TE TA with light <strong>and</strong> protection diode<br />

TJ Dual tabs (male only)<br />

TK TJ with protection diode<br />

TM TJ with light<br />

TN TJ with light <strong>and</strong> protection diode<br />

*DN Plug-in with diode<br />

*DP Plug-in with M.O.V.<br />

*DH Plug-in with diode & ground<br />

*DJ Plug-in with M.O.V & ground<br />

* These options only apply to the 92 series. All others are for the 400 <strong>and</strong> 52 series.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

PIN #6<br />

PIN #9<br />

MOD. SD09<br />

PIN #1<br />

PIN #5<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 9<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 7 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 2 common wires<br />

PIN #9<br />

PIN #15<br />

MOD. SD15<br />

PIN #1<br />

PIN #8<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 15<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 12 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 3 common wires<br />

PIN #14<br />

PIN #25<br />

MOD. SD25<br />

PIN #1<br />

PIN #13<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 25<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 20 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 5 common wires<br />

Note : Use desired MOD. number after circuit bar part number


O p t i o n s<br />

OPTIONS<br />

Connector termination details<br />

CONNECTOR<br />

SOL 1<br />

SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />

Single solenoid circuit bar<br />

SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />

CONNECTOR<br />

SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />

Double solenoid circuit bar<br />

SD09 SD15 SD25<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

8<br />

COMMON (+)<br />

13<br />

COMMON (+)<br />

21<br />

COMMON (+)<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

9<br />

COMMON (+)<br />

8<br />

SOL. 8<br />

8<br />

SOL. 8<br />

14<br />

COMMON (+)<br />

22<br />

COMMON (+)<br />

9<br />

SOL. 9<br />

9<br />

SOL. 9<br />

10 SOL. 10<br />

10 SOL. 10<br />

11<br />

SOL. 11<br />

11<br />

SOL. 11<br />

12 SOL. 12<br />

12 SOL. 12<br />

15<br />

COMMON (+)<br />

23<br />

COMMON (+)<br />

13<br />

SOL. 13<br />

14 SOL. 14<br />

15<br />

SOL. 15<br />

16 SOL. 16<br />

24<br />

COMMON (+)<br />

17<br />

18 SOL. 18<br />

19<br />

20 SOL. 20<br />

SOL. 17<br />

SOL. 19<br />

25<br />

COMMON (+)


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 800<br />

Circuit bar mounting<br />

cylinder ports<br />

in valve<br />

with shut-off<br />

valve<br />

Sealed solenoid enclosure<br />

Piston assembly<br />

Manual operator<br />

Piston adapter<br />

Bonded spool<br />

2<br />

3<br />

Air/spring return<br />

4 1 5<br />

Internal pilot supply<br />

Optional pilot exhaust<br />

tapped port or<br />

Integral muffler<br />

SERIES FEATURES<br />

• Patented MACSOLENOID ® with its non-burn out feature on AC service.<br />

• Air/spring return on single solenoid valves.<br />

• Use for lube or non-lube service.<br />

• Optional low wattage DC solenoids down to 1 watt.<br />

• Various types of manual operators <strong>and</strong> solenoid enclosures.<br />

• 2 position or 3 position valve configurations.<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 800<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/4” 1.3C v<br />

cylinder ports<br />

in valve<br />

OPERATIONAL BENEFITS<br />

1. Balanced spool, immune to variations of pressure.<br />

2. Short stroke with high flow.<br />

3. The piston (booster) provides maximum shifting<br />

forces.<br />

4. Powerful return force thanks to the combination of<br />

mechanical <strong>and</strong> air springs.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Wiping effect eliminates sticking.<br />

7. Pilot valve with balanced poppet, high flow, short<br />

<strong>and</strong> consistent response times.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-PM-xxxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

A 3 2 B<br />

A 3 2 B<br />

B 2 3 A<br />

B 2 3 A<br />

B 2 3 A<br />

5 1<br />

4<br />

5 1<br />

4<br />

4 1 5<br />

4 1 5<br />

4 1 5<br />

1/4” NPTF<br />

811C-PM-XXYZZ-172<br />

821C-PM-XXYZZ-172<br />

825C-PM-XXYZZ-572<br />

825C-PM-XXYZZ-672<br />

825C-PM-XXYZZ-872<br />

SOLENOID OPERATOR ➤<br />

XX Y ZZ *<br />

Voltage<br />

11 120/60, 110/50<br />

12 240/60, 220/50<br />

22 24/50, 24/60<br />

59 24VDC (2.5 W)<br />

87 24VDC (17.1 W)<br />

61 24VDC (8.5 W)<br />

xx Other Options<br />

Manual operator<br />

1 Non-locking<br />

2 Locking<br />

xx Other Options<br />

Electrical connection<br />

JB Rectangular connector<br />

JD Rectangular connector<br />

with light<br />

BA Flying leads (18”)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR**<br />

Port size<br />

(Spacing 31 mm)<br />

3/8” NPTF<br />

St<strong>and</strong>ard circuit bar<br />

EBM800A-001A-XX<br />

EBM800A-xxxx-xx<br />

Circuit bar with flow controls<br />

(2 per station)<br />

EBM800A-002A-XX<br />

Number of stations (03=3 stations)<br />

Other options available. Consult factory.<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 800<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : single operator <strong>and</strong> 3 positions : 20 to 150 PSI<br />

double operator : 10 to 150 PSI<br />

External pilot : vacuum to 200 PSI<br />

Single operator <strong>and</strong> 3 positions : 20 to 150 PSI<br />

Double operator : 20 to 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

7 mm<br />

1/4" : 1.3 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 14.8 VA Holding : 10.9 VA<br />

= 1 to 17.1 W<br />

24 V=/8.5 W Energize : 8 ms De-energize : 10ms<br />

60Hz/6 W Energize : 5-11 ms De-energize : 9-16 ms<br />

• Pilot valve : PME-XXYZZ. • Mounting screw pilot to main valve : 34364. • Blanking plate : M-08008.<br />

• Mounting screw valve to bar (x2): 35249. • Flow control : N08006.<br />

Options :<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust. • Explosion-proof model.<br />

DIMENSIONS<br />

183,2<br />

136,0<br />

91,5<br />

56,0<br />

89,2<br />

IN<br />

18,5<br />

EXH<br />

EXH<br />

15,5<br />

7,0<br />

EX IN EX<br />

3<br />

4<br />

3<br />

4<br />

3<br />

4<br />

3<br />

15,0 12,7<br />

15,0 12,7<br />

4<br />

3<br />

4<br />

3<br />

4<br />

EX IN EX<br />

Ø 6,7<br />

2 MTG HOLES<br />

12,0<br />

42,0<br />

72,0<br />

84,0<br />

FLOW CONTROL<br />

3/8”<br />

7,0<br />

31,0<br />

31,5<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid <strong>and</strong> solenoid pilot operated valves<br />

Series 800<br />

Function Port size Flow (Max) Circuit bar mounting<br />

5/2 - 5/3 1/4” 1.3C v<br />

with shut-off<br />

valve<br />

OPERATIONAL BENEFITS<br />

1. Balanced spool, immune to variations of pressure.<br />

2. Short stroke with high flow.<br />

3. The piston (booster) provides maximum shifting<br />

forces.<br />

4. Powerful return force thanks to the combination of<br />

mechanical <strong>and</strong> air springs.<br />

5. Bonded spool with minimum friction, shifting in a<br />

glass-like finished bore.<br />

6. Wiping effect eliminates sticking.<br />

7. Pilot valve with balanced poppet, high flow, short<br />

<strong>and</strong> consistent response times.<br />

8. Long service life.<br />

Reset<br />

HOW TO ORDER<br />

xxxx-PM-xxxxx-xxx<br />

HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING<br />

Port size<br />

5/2<br />

Single operator<br />

5/2<br />

Double operator<br />

5/3<br />

Closed center<br />

5/3<br />

Open center<br />

5/3<br />

Pressure center<br />

A 3 2 B<br />

A 3 2 B<br />

B 2 3 A<br />

B 2 3 A<br />

B 2 3 A<br />

5 1<br />

4<br />

5 1<br />

4<br />

4 1 5<br />

4 1 5<br />

4 1 5<br />

1/4” NPTF<br />

811C-PM-XXYZZ-172<br />

821C-PM-XXYZZ-172<br />

825C-PM-XXYZZ-572<br />

825C-PM-XXYZZ-672<br />

825C-PM-XXYZZ-872<br />

SOLENOID OPERATOR ➤<br />

XX Y ZZ *<br />

Voltage<br />

11 120/60, 110/50<br />

12 240/60, 220/50<br />

22 24/50, 24/60<br />

59 24VDC (2.5 W)<br />

87 24VDC (17.1 W)<br />

61 24VDC (8.5 W)<br />

xx Other Options<br />

Manual operator<br />

1 Non-locking<br />

2 Locking<br />

xx Other Options<br />

Electrical connection<br />

JB Rectangular connector<br />

JD Rectangular connector<br />

with light<br />

BA Flying leads (18”)<br />

xx Other Options<br />

HOW TO ORDER CIRCUIT BAR**<br />

Port size<br />

(Spacing 31 mm)<br />

w/o inlet shut-off valve<br />

EBI800A-xxxx-xx<br />

w/ inlet shut-off valve<br />

3/8" NPTF<br />

EBI800A-001A-XX<br />

EBI800A-002A-XX<br />

Number of stations (03=3 stations)<br />

Other options available. Consult factory.<br />

Note : clic for valves mounted on base at the factory (add - 9 to the model number).<br />

Consult “Precautions”before use, installation or service of MAC Valves.


100%<br />

100%<br />

WARRANTY<br />

18<br />

O F<br />

P R O D U C T I O N<br />

T E S T E D<br />

100% MONTHS<br />

Series 800<br />

T E C H N I C A L<br />

D A T A<br />

Fluid :<br />

Pressure range :<br />

Pilot pressure :<br />

Lubrication :<br />

Filtration :<br />

Temperature range :<br />

Orifice :<br />

Flow (at 6 bar, P=1bar) :<br />

Leak rate :<br />

Coil :<br />

Voltage range :<br />

Protection :<br />

Power :<br />

Response times :<br />

Spare parts :<br />

Compressed air, vacuum, inert gases<br />

Internal pilot : single operator <strong>and</strong> 3 positions : 20 to 150 PSI<br />

double operator : 10 to 150 PSI<br />

External pilot : vacuum to 200 PSI<br />

Single operator <strong>and</strong> 3 positions : 20 to 150 PSI<br />

Double operator : 20 to 150 PSI<br />

Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)<br />

40 μ<br />

0°F to 120°F (-18°C to +50°C)<br />

7 mm<br />

1/4" : 1.3 C v<br />

50 cm 3 /min<br />

General purpose class A, continuous duty, encapsulated<br />

-15% to +10% of nominal voltage<br />

NEMA 4<br />

Inrush : 14.8 VA Holding : 10.9 VA<br />

= 1 to 17.1 W<br />

24 V=/8.5 W Energize : 8 ms De-energize : 10ms<br />

60Hz/6 W Energize : 5-11 ms De-energize : 9-16 ms<br />

• Pilot valve : PME-XXYZZ. • Mounting screw pilot to main valve : 34364. • Blanking plate : M-08011.<br />

• Shut-off valve : M-08010. • Mounting screw valve to bar (x2): 35249.<br />

Options :<br />

• BSPP threads. • Isolation of inlet <strong>and</strong>/or exhaust. • Explosion-proof model.<br />

DIMENSIONS<br />

183,2<br />

91,6<br />

56,0<br />

19,0<br />

K<br />

C<br />

O<br />

L<br />

3<br />

2<br />

K<br />

C<br />

O<br />

L<br />

102,2<br />

L<br />

K<br />

L<br />

O<br />

C<br />

O<br />

O<br />

K<br />

C<br />

L<br />

K<br />

C<br />

3<br />

3<br />

3<br />

2<br />

2<br />

2<br />

L<br />

K<br />

L<br />

O<br />

C<br />

O<br />

K<br />

C<br />

O<br />

L<br />

K<br />

C<br />

13,0<br />

SHOWN IN OPEN<br />

POSITION<br />

3/8”<br />

Ø 4<br />

MTG. HOLES<br />

9,5<br />

19,0<br />

26,0<br />

13,0<br />

19,0<br />

SHOWN IN<br />

CLOSED POSITION<br />

EXH<br />

40,0<br />

111,0<br />

71,0<br />

Consult “Precautions”before use, installation or service of MAC Valves.


Section 2 Options<br />

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Codification table for voltages / Manual operator / Electrical connection / Wire length<br />

VALVE CODE ➤<br />

- XX Y ZZ (-VV)<br />

1 2 3 4<br />

OPTIONS AVAILABLE FOR<br />

- valves type 800 Series<br />

Consult “Precautions”before use, installation or service of MAC Valves.


OPTIONS<br />

Back<br />

1. VOLTAGE<br />

- XX Y ZZ VOLTAGE<br />

11 120/60 - 110/50<br />

12 240/60 - 220/50<br />

13 100/60 - 100/50<br />

15 200/60 - 200 V~/50 Hz<br />

16 10/60<br />

20 6/60<br />

21 12/50 - 12/60<br />

22 24/60 - 24/50<br />

23 32/60 - 32/50<br />

24 48/60 - 42/50<br />

26 380/50, 440/50 -440/60,<br />

480/60-CLSF<br />

29 200/60<br />

34 127/50 - 120/50<br />

35 48/50<br />

36 16/60<br />

B1 24/50<br />

50 24 VDC (6W)<br />

51 24 VDC (4W)<br />

54 12 VDC (4W)<br />

55 12 VDC (6W)<br />

57 12 VDC (2.5W)<br />

59 24 VDC (2.5W)<br />

60 12 VDC (8.5W)<br />

61 24 VDC (8.5W)<br />

64 6 VDC (6W)<br />

65 32 VDC (7W)<br />

66 48 VDC (5.8W)<br />

67 64 VDC (7.5W)<br />

68 120 VDC (6.4W)<br />

75 90 VDC (8.8W)<br />

76 100 VDC (6.9W)<br />

*84 125 VDC (10.9W)<br />

*87 24 VDC (17.1W)<br />

*88 12 VDC (17.4W)<br />

*89 36 VDC (18.8W)<br />

90 28 VDC (8.2W)<br />

*91 6 VDC (10.6W)<br />

92 190 VDC (6.5W)<br />

94 3 VDC (7W)<br />

95 38 VDC (6.4W)<br />

A1<br />

24 VDC (1.0W)<br />

A2<br />

12 VDC (1.0W)<br />

A3<br />

9 VDC (1.0W)<br />

MOD. DD01 : Protection diode (DC)<br />

MOD. MOV1 : Protection varistor (AC)<br />

MOD. DD01 : max. 8,5 W<br />

MOD. MOV1 : max. 8,5 W<br />

* Voltages are CLSF only<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

Back<br />

2. MANUAL OPERATOR<br />

- XX Y ZZ MANUAL OPERATOR<br />

0 No operator<br />

1 Non-locking recessed<br />

2 Locking recessed<br />

3 Non-locking extended<br />

4 Locking extended<br />

3. ELECTRICAL CONNECTION<br />

- XX Y ZZ ELECTRICAL CONNECTION<br />

AA Wiring box with 1/2" NPS conduit<br />

BA Flying leads<br />

CA 1/2" NPS conduit<br />

CC 1/2" NPT conduit<br />

FA Military type 2 PIN<br />

GA Military type 3 PIN<br />

HA AA with ground wire<br />

JA Square connector<br />

JB Rectangular connector<br />

JC Square connector with light<br />

JD Rectangular connector with light<br />

JJ Square connector, male only<br />

JM Rectangular connector, male only<br />

NA CA with ground wire<br />

NC CC with ground wire<br />

RA 3/8" NPS conduit<br />

CD 20 mm conduit<br />

4. WIRE LENGTH<br />

- XX Y ZZ (-VV) WIRE LENGTH<br />

AA 18”<br />

AB 24”<br />

AD 36”<br />

AE 48”<br />

AF 72”<br />

AG 6”<br />

AR 12”<br />

AU 120”<br />

BA 60”<br />

BB 144”<br />

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s<br />

OPTIONS<br />

PIN #6<br />

PIN #9<br />

MOD. SD09<br />

PIN #1<br />

PIN #5<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 9<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 7 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 2 common wires<br />

PIN #9<br />

PIN #15<br />

MOD. SD15<br />

PIN #1<br />

PIN #8<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 15<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 12 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 3 common wires<br />

PIN #14<br />

PIN #25<br />

MOD. SD25<br />

PIN #1<br />

PIN #13<br />

TECHNICAL DATA<br />

• Type «SUB_D»<br />

• Number of contacts : 25<br />

• Solder termination (Dia. 0.6 mm/0.14 mm 2 /26-22 AWG)<br />

• Operating current 5 A/contact<br />

• Rated voltage 125 V~<br />

• Temp. range –40° to +125°C<br />

• Insulation resistance 5.0 9 <br />

• Protection class IP40 (DIN 40050)<br />

• Number of solenoids : 20 max.<br />

• Max. 24 V=/5.4 W per solenoid<br />

• 5 common wires<br />

Note : Use desired MOD. number after circuit bar part number


O p t i o n s<br />

OPTIONS<br />

Connector termination details<br />

CONNECTOR<br />

SOL 1<br />

SOL 2 SOL 3 SOL .. SOL 20 SOL 21 SOL 22 SOL 23 SOL 24<br />

Single solenoid circuit bar<br />

SOL 2 SOL 4 SOL 6 SOL 8 SOL 16 SOL 18 SOL 20 SOL 22 SOL 24<br />

CONNECTOR<br />

SOL 1 SOL 3 SOL 5 SOL 13 SOL 15 SOL 17 SOL 19 SOL 21 SOL 23<br />

Double solenoid circuit bar<br />

SD09 SD15 SD25<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

1<br />

SOL. 1<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

2<br />

SOL. 2<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

3<br />

SOL. 3<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

4<br />

SOL. 4<br />

8<br />

COMMON (+)<br />

13<br />

COMMON (+)<br />

21<br />

COMMON (+)<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

5<br />

SOL. 5<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

6<br />

SOL. 6<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

7<br />

SOL. 7<br />

9<br />

COMMON (+)<br />

8<br />

SOL. 8<br />

8<br />

SOL. 8<br />

14<br />

COMMON (+)<br />

22<br />

COMMON (+)<br />

9<br />

SOL. 9<br />

9<br />

SOL. 9<br />

10 SOL. 10<br />

10 SOL. 10<br />

11<br />

SOL. 11<br />

11<br />

SOL. 11<br />

12 SOL. 12<br />

12 SOL. 12<br />

15<br />

COMMON (+)<br />

23<br />

COMMON (+)<br />

13<br />

SOL. 13<br />

14 SOL. 14<br />

15<br />

SOL. 15<br />

16 SOL. 16<br />

24<br />

COMMON (+)<br />

17<br />

18 SOL. 18<br />

19<br />

20 SOL. 20<br />

SOL. 17<br />

SOL. 19<br />

25<br />

COMMON (+)


364<br />

PRECAUTIONS AND WARNINGS<br />

CONCERNING THE APPLICATION, INSTALLATION AND SERVICE OF MAC VALVES AND OTHER MAC VALVES PRODUCTS<br />

The warnings <strong>and</strong> precautions below are important to be read <strong>and</strong> understood before<br />

designing into a system any MAC Valves products, <strong>and</strong> before installing or servicing any MAC Valves<br />

product. Improper use, installation or servicing of any MAC Valves product in some systems could<br />

create a hazard to personnel or equipment. No distinction in importance should be made between<br />

the terms warnings <strong>and</strong> precautions.<br />

WARNING : .<br />

Under no circumstances are MAC Valves products to be used in any application or in any manner<br />

where failure of the MAC Valves product to operate as intended could in any way jeopardize the<br />

safety of the operator or any other person or property.<br />

• Do not operate outside of pressure range listed on a valve label or outside of the designated<br />

temperature range.<br />

• Air supply must be clean <strong>and</strong> dry. Moisture or contamination can affect proper operation of the<br />

valve.<br />

• Before attempting to repair, adjust or clean a MAC Valves product, consult catalog, parts & operation<br />

sheet, or factory for proper maintenance procedures, lubrication <strong>and</strong> cleaning agents. Never<br />

attempt to repair or perform other maintenance with air pressure to the valve.<br />

• If air line lubrication is used do not use any lubrication other than those recommended in the<br />

catalog, parts & operation sheet or by the factory.<br />

APPLICATION PRECAUTIONS : .<br />

INDUSTRIAL USE -<br />

• MAC Valve products are intended for general use in industrial pneumatic <strong>and</strong>/or vacuum systems.<br />

They are general purpose industrial products with literally thous<strong>and</strong>s of different applications in<br />

industrial systems. These products are not inherently dangerous, but they are only a component of<br />

an overall system. The system in which they are used must provide adequate safeguards to prevent<br />

injury or damage in the event failure occurs, whether it be failure of switches, regulators, cylinders,<br />

valves or any other component.<br />

POWER PRESSES -<br />

MAC Valve products are not designed nor intended to be used to operate <strong>and</strong>/or control the<br />

operation of clutch <strong>and</strong>/or brake systems on power presses. There are special products on the market<br />

for such use.<br />

2-POSITION VALVES -<br />

Some MAC valves are 2-position, 4-way valves. When air is supplied to the inlet port(s) of these valves,<br />

there will always be a flow path from the inlet to one of the outlets regardless of which of the two<br />

positions the valve is situated. Therefore, if pressurized air retained in the system would present a<br />

hazard in the application or servicing of the valve or system, a separate method in the system must<br />

be provided to remove the trapped air.<br />

3- POSITION VALVES-<br />

Some MAC valves are 3-position, 4-way valves. These valves are either double solenoid or double<br />

remote air operated.<br />

If either of the two operators is in control, air supplied to the inlet port(s) will pass through the valve<br />

to one of the outlets as on 2-position, 4-way valves. However, if neither operator is in control, the<br />

valve moves to a center position. Listed below are the various center position functions :<br />

A. CLOSED CENTER-<br />

With this type valve, when in the center position all ports are blocked (inlets <strong>and</strong> exhausts) meaning<br />

the air at both outlet ports is trapped. If trapping the air in both outlet ports would present a hazard<br />

in the application or servicing, a separate method in the system must be provided to remove the<br />

trapped air or this type valve should not be used.<br />

B. OPEN CENTER-<br />

With this type valve, when in the center position, the inlet port(s) is blocked <strong>and</strong> the two outlet ports<br />

are open to the exhaust port(s) of the valve. If having no air in either outlet port would present a<br />

hazard in the application or servicing, this type valve should not be used.<br />

C. PRESSURE CENTER-<br />

With this type valve, when in the center position, the inlet port(s) is connected to both outlet ports of<br />

the valve. If having pressurized air to either or both outlet ports would present a hazard in the<br />

application or servicing of the valve or system, a separate method in the system must be<br />

provided to remove the retained air or this type valve should not be used.<br />

OPERATING SPECIFICATIONS -<br />

MAC Valves products are to be installed only on applications that meet all operating specifications<br />

described in the MAC catalog for the MAC Valves product.<br />

MANUAL OPERATORS-<br />

Most MAC valves can be ordered with manual operators. Manual operators when depressed, are<br />

designed to shift the valve to the same position as would the corresponding solenoid or remote air<br />

pilot operator if it were activated. Care must be taken to order a type, if any, that will be safe for the<br />

physical location of the manual operator in the system. If intentional or accidental operation of a<br />

valve by a manual operator could cause personal injury or property damage, a manual operator<br />

should not be used.<br />

REMOTE AIR OPERATED VALVES<br />

Pilot valves supplying signal pressure to remote air operated valves should be 3-way valves with<br />

adequate supply <strong>and</strong> exhaust capacity to provide positive pressurizing <strong>and</strong> exhausting of the pilot<br />

supply line. Pilot lines should be open to exhaust when valves are deenergized.<br />

INSTALLATION PRECAUTIONS : .<br />

A. Do not install any MAC Valves product without first turning off air (bleed system completely) <strong>and</strong><br />

electricity to the machine.<br />

B. MAC Valves products should only be installed by qualified, knowledgeable personnel who<br />

underst<strong>and</strong> how the specific valve is to be pneumatically piped <strong>and</strong> electrically connected (where<br />

applicable). Flow paths through the valve are shown in the catalog <strong>and</strong> on the valve by use of ANSI<br />

or ISO type st<strong>and</strong>ard graphic symbols. Do not install unless these symbols <strong>and</strong> the valve functions<br />

<strong>and</strong> operations are thoroughly understood.<br />

C. If air line lubrication is used do not use any lubrication other than those recommended in the<br />

catalog, parts & operation sheet or by the factory.<br />

SERVICE PRECAUTIONS :<br />

A. Do not service or remove from service any MAC Valves product without first shutting off both the<br />

air <strong>and</strong> electricity to the valve <strong>and</strong> making certain no pressurized air which could present a hazard<br />

is retained in the system.<br />

B. MAC Valves products should only be serviced or removed from service by qualified, knowledgeable<br />

personnel who underst<strong>and</strong> how the specific product is used <strong>and</strong>/or how the specific valve is piped<br />

<strong>and</strong> used <strong>and</strong> whether there is air retained in the connecting lines to the valve or electric power still<br />

connected to the valve.<br />

C. Before attempting to repair, adjust or clean a MAC Valves product, consult catalog, parts &<br />

operation sheet, or factory for proper maintenance procedures, lubrication <strong>and</strong> cleaning agents.<br />

Never attempt to repair or perform other maintenance with air pressure to the valve.<br />

D. MAC Valves products are never to be stepped on while working on a machine. Damage to a MAC<br />

valve, or other product or lines to the product (either air or electrical lines) or accidental activation<br />

of a manual operator on the valve could result in personal injury or property damage.<br />

LIMITATION OF GUARANTEE .<br />

This Guarantee is limited to the replacement or rebuilding of any valve or other product which should<br />

fail to operate properly. Valves or other products, under the MAC Guarantee, must be returned (with<br />

or without bases) transportation prepaid <strong>and</strong> received at our factory within the Guarantee period.<br />

They will be returned to the customer at the expense of MAC Valves, Inc., <strong>and</strong> will carry the same<br />

guarantee as provided under the Flat Rate Rebuild Program.<br />

DISCLAIMER OF GUARANTEE .<br />

No claims for labor, material, time, damage, or transportation are allowable nor will any valve or other<br />

product be replaced or rebuilt under this guarantee which has been damaged by the purchaser not<br />

in the normal course of its use <strong>and</strong> maintenance during the warranty period. The guarantee does not<br />

apply to loss or damage caused by fire, theft, riot, explosion, labor dispute, act of God, or other causes<br />

beyond the control of MAC Valves,Inc. MAC Valves, Inc. shall in no event be liable for remote, special<br />

or consequential damages under the MAC Guarantee, nor under any implied warranties, including<br />

the implied warranty of merchantability.<br />

The above Guarantee is our manner of extending the engineering <strong>and</strong> service resources of the MAC<br />

Valves, Inc. organization to assure our customer long, <strong>and</strong> continued satisfaction.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!