RUBBER <strong>CABLES</strong><br />

Type Standard Rated voltage Similar Application<br />

NGFLGöu<br />

MGG<br />

MGCG<br />

FMGCG<br />

DIN VDE<br />

0250-609<br />

Production<br />

Specification<br />

of <strong>Novkabel</strong><br />

Production<br />

Specification<br />

of <strong>Novkabel</strong><br />

DIN 89159<br />

DIN 89158<br />

DIN 89160<br />

300/500 V<br />

300/500 V<br />

450/750 V<br />

0,6/1 kV<br />

0,6/1 kV<br />

250/250 V<br />

NFK SiSi/J<br />

NFK TES<br />

HALOGEN FREE <strong>CABLES</strong><br />

Rubber flexible flat cable is used for<br />

connecting mobile parts of the machines,<br />

conveyor systems and large machines with<br />

medium mechanical stresses and torsion.<br />

Silicone flexible flat cable is used for<br />

connecting mobile parts of the machines,<br />

conveyor systems and large machines as<br />

power, signal and control cable.<br />

Flexible rubber cable is intended<br />

for pumps under water.<br />

Rubber insulated cable is intended for fixed<br />

laying on ships and off-shore units, use in<br />

all rooms and on open board, as power,<br />

signalling and control cables.<br />

Rubber insulated cable with protective<br />

conductor is used for fixed laying on ships<br />

and off-shore units, use in all rooms and<br />

on open board, as power, signalling and<br />

control cables.<br />

Teledommunication shipboard cable is<br />

used for fixed laying on ships and off-shore<br />

units, use in all rooms and on open board,<br />

as signalling and control cables.<br />

H05Z-U<br />

H05Z-K<br />

DIN VDE<br />

0282-9<br />

DIN VDE<br />

0282-9<br />

300/500 V<br />

300/500 V<br />

Halogen free single core non sheated<br />

cables with improved characteristics in<br />

the case of fire are intended for wiring,<br />

for installations in the dry room, lighting<br />

equipment and control instruments.<br />

H07Z-U<br />

H07Z- R<br />

H07Z-K<br />

DIN VDE<br />

0282-9<br />

DIN VDE<br />

0282-9<br />

DIN VDE<br />

0282-9<br />

450/750 V<br />

450/750 V<br />

450/750 V<br />

Halogen free single core non sheated<br />

cables with improved characteristics<br />

in the case of fire are intended for wiring<br />

in pipes or raceways, for installations in<br />

the dry room, lighting equipment and<br />

control instruments.<br />

H07ZZ-F<br />

DIN VDE<br />

0282-13<br />

450/750 V<br />

These cables are used for connecting<br />

electrical appliances and tools,<br />

and installations with medium<br />

mechanical stresses.<br />

NHXHX<br />

NHXCHX<br />

DIN VDE<br />

0266<br />

DIN VDE<br />

0266<br />

0,6/1 kV<br />

0,6/1 kV<br />

Halogen free cables, with concentric<br />

conductor (C) or not, are intended for<br />

installation in the object where there<br />

are rather large requirements for safety<br />

of people.<br />

NHXHX<br />

FE180<br />

NHXCHX<br />

FE180<br />

DIN VDE<br />

0266<br />

DIN VDE<br />

0266<br />

0,6/1 kV<br />

0,6/1 kV<br />

These cables, with concentric conductor<br />

(C) or not, are particularly suitable for<br />

installation which should be functional in<br />

the case of the fire (power supply pumps,<br />

equipment to extinguish a fire, ventilators<br />

for pulling out of smoke, panic lighting, etc).<br />

6 <strong>CABLES</strong> <strong>AND</strong> <strong>WIRES</strong>