C3.1.2 - Terminal blocks and type<br />

of cable gland for <strong>PLS</strong> 315 MG to<br />

400 <strong>motors</strong><br />

Whatever the number of poles, cable glands<br />

are optional because of the large number of<br />

power cable combinations. <strong>PLS</strong> 315 MG to<br />

400 <strong>motors</strong> with 2, 4, 6 and 8 poles are<br />

supplied with a removable and undrilled<br />

cable gland mounting plate.<br />

If you wish to receive a pre-drilled plate<br />

fitted with cable glands, your order must<br />

specify the number of cables, their diameter<br />

and the type of cable gland required.<br />

<strong>PLS</strong> 315 MG/LG/VLG/VLGU <strong>motors</strong> are<br />

supplied with M 12 terminal blocks.<br />

Motors of frame size 355 and 400 are<br />

supplied with M14 insulators.<br />

C3.2 - WIRING DIAGRAMS<br />

All standard <strong>motors</strong> are supplied with a<br />

wiring diagram in the terminal box.<br />

The diagram normally used is shown below.<br />

C3.3 - EARTH TERMINAL<br />

This is situated inside the terminal box.<br />

Consisting of a threaded stud with a<br />

hexagonal nut, it is used to connect cables<br />

with cross-sections at least as large as the<br />

cross-section of the <strong>phase</strong> conductors.<br />

It is indicated by the sign in the terminal<br />

box moulding.<br />

On request, a second earth terminal can be<br />

fitted on the motor casing.<br />

16<br />

W2 U2 V2<br />

3-PHASE MOTOR<br />

1 SPEED - 2 VOLTAGES<br />

U1 V1 W1<br />

L1 - L2 - L3<br />

L1 L2 L3 L1 L2 L3<br />

LOWER VOLTAGE HIGHER VOLTAGE<br />

<strong>PLS</strong><br />

<strong>Drip</strong>-<strong>proof</strong> 3-<strong>phase</strong> <strong>induction</strong> <strong>motors</strong><br />

Construction<br />

W2 U2 V2<br />

U1 V1 W1<br />

C3 - Mains connection<br />

C3.4 - FLYING LEADS<br />

Motors can be supplied with flying leads or<br />

multicore cables (ask for estimate). Please<br />

state cable characteristics (type and<br />

supplier, cross-section, length, number of<br />

conductors), connection method (on stator<br />

coil end turns, or on a separate panel), and<br />

the cable gland position required.