VOLTS<br />
VOLTS<br />
CAT ® BATTERY SPECIFICATIONS<br />
CAT ®<br />
GENERAL SERVICE BATTERIES<br />
— AVAILABLE WORLDWIDE —<br />
VALVE REGULATED LEAD ACID (VRLA) BATTERIES<br />
GENERAL INFORMATION<br />
BCI<br />
GROUP<br />
SIZE<br />
PART NO.<br />
CCA ≈<br />
RC<br />
MINS<br />
†<br />
AMP HR<br />
CAP.<br />
@ 20<br />
HRS.<br />
CONST.<br />
NOTES<br />
LENGTH<br />
IN (MM)<br />
GELLED (GEL) ELECTROLYTE - MARINE / RECREATIONAL - DEEP CYCLE CAPABILITY<br />
BCI OVERALL DIMENSIONS<br />
WIDTH<br />
IN (MM)<br />
HEIGHT<br />
IN (MM)<br />
NOMINAL<br />
WEIGHT<br />
WET<br />
LB (KG)<br />
4D 152-8006 970 375 12 183 MF-G/VRLA 20.8 (528) 8.5 (216) 10 (254) 129.8 (59)<br />
8D 152-7242 1150 475 12 225 MF-G/VRLA 20.8 (528) 11.1 (282) 10 (254) 160.8 (73)<br />
MF-G/VRLA - Maintenance Free-Gel Battery. Sealed, Valve-Regulated Lead<br />
Acid (VRLA) battery with gelled electrolyte.<br />
≈ - Cold Cranking Amps for 30 seconds at 0°F (-18°C)<br />
† - Reserve Capacity Minutes minimum of 25 amp output at 80°F (27°C)<br />
• Starting/Deep Cycle Marine or Recreational Use Battery. Could be used<br />
for Gen-Sets or UPS type applications requiring a sealed battery.<br />
• VRLA batteries use recombination reaction to prevent the escape of<br />
hydrogen and oxygen gases normally lost in a flooded lead acid battery.<br />
They are non-spillable, never need watering and should never be opened.<br />
BCI<br />
GROUP<br />
SIZE<br />
PART NO. A B<br />
C<br />
CONST.<br />
NOTES<br />
TERM.<br />
LENGTH<br />
IN (MM)<br />
BCI OVERALL DIMENSIONS<br />
WIDTH<br />
IN (MM)<br />
TERMINAL<br />
HEIGHT<br />
IN (MM)<br />
CONTAINER<br />
HEIGHT<br />
IN (MM)<br />
NOMINAL<br />
ABSORBED GLASS MAT (AGM) BATTERIES - DESIGNED FOR HIGH-RATE UNINTERRUPTIBLE POWER SUPPLIES (UPS) OR STANDBY APPLICATIONS<br />
U1 250-0474 116 62 1.63 12 MF-AGM/VRLA 1 7.7 (196) 5.1 (132) 7.1 (182) 6.2 (157) 24 (11)<br />
45 250-0475 156 84.3 2.75 12 MF-AGM/VRLA 2 8.8 (225) 5.3 (135) 8.7 (221) 8.1 (207) 38.5 (18)<br />
24 250-0476 262 140 3.95 12 MF-AGM/VRLA 2 10.2 (259) 6.8 (173) 9.1 (232) 8.1 (206) 53 (24)<br />
27 250-0477 304 165 4.61 12 MF-AGM/VRLA 2 12.7 (323) 6.8 (173) 8.7 (220) 8.1 (206) 63 (29)<br />
31 250-0478 350 186 5.25 12 MF-AGM/VRLA 3 12.9 (329) 6.7 (171) 8.7 (222) 8.5 (218) 69 (31)<br />
31 250-0479 475 261 6.66 12 MF-AGM/VRLA 3 13.5 (342) 6.7 (172) 11.2 (286) 11.1 (281) 98 (45)<br />
4D 250-0483 624 338 9.91 12 MF-AGM/VRLA 4 21.7 (552) 8.8 (210) 9.3 (237) 8.7 (22) 129 (59)<br />
A - Power Watts per Cell for 15 minutes to 1.67 Volts Per Cell<br />
@ 77°F (25°C)<br />
B - Amp Hour @ 20 Hour Rate to 1.75 Volts Per Cell @ 77°F (25°C)<br />
C - Amp Hour @ 10 Hour Rate to 1.80 Volts Per Cell @ 68°F (20°C)<br />
MF-AGM/VRLA - Maintenance Free-Absorbed Glass Mat (AGM) Battery.<br />
• Sealed Valve-Regulated Lead Acid (VRLA) with electrolyte absorbed in<br />
separators consisting of a sponge-like mass of matted glass fibers.<br />
• Preferred for high-rate performance in uninterruptible power supply<br />
(UPS) or standby applications.<br />
• VRLA batteries use recombination reaction to prevent the escape of<br />
hydrogen and oxygen gases normally lost in a flooded lead acid battery.<br />
They are non-spillable, never need watering and should never be opened.<br />
Terminals:<br />
1 - Lead terminal. L Shaped. Terminals have square holes.<br />
2 - Lead terminal with brass inserts. 1/4-20 x .25 Deep Female Thread.<br />
3 - Lead terminal with brass inserts. 1/4-20 x .25 Deep Female Thread.<br />
4 - Lead terminal with brass inserts. 1/4-20 x Female Thread.<br />
• Ratings conform to IEEE-485 Standards.<br />
1 - BCI<br />
Group U1<br />
2 - BCI<br />
Groups 45,<br />
24, 27<br />
3 - BCI<br />
Group 31<br />
4 - BCI<br />
Group 4D<br />
Transit Bus Terminal for 8D Part # 250-0473<br />
One piece end terminal. Right end of Battery.<br />
1/2" - 13 Steel Postitive Stud<br />
3/8" - 16 Steel Negative Stud<br />
Battery Accessories:<br />
• Group 31 - Charging Posts for Stud Terminals - Part # 4C-5637<br />
• Screw-in Charging Posts for Side Terminals - Part # 4C-5638<br />
• Wing Nut for Part # 175-4390/175-4370/175-4360/8C-3628 - Part # 2B-9498<br />
• Wing Nut for Part # 8C-3638 & 8C-3639 Marine <strong>Batteries</strong> - Part # 3B-0723<br />
• Digital Battery Analyzer - Part # 177-2330<br />
• Battery Voltmeter - Part # 4C-6600<br />
• Battery Load Tester - Part # 4C-4911<br />
• Booster Cable 12' (3.66 m) - Part # 4C-4933<br />
• Booster Cable 20' (6.00 m) - Part # 4C-4937<br />
* Note: Ratings and Part Numbers are subject to change without notice.<br />