CONTA-<strong>ELECTRONICS</strong><br />
Potentiometric converter units CML<br />
CML-POT-UI<br />
· Mount on TS 35<br />
· Compact design, width: 6.2mm<br />
· Screw-clamp connection<br />
· Conversion of potentiometer signals into standard<br />
analog signals<br />
· Suitable for 1 k to 20 k Ω potentiometer<br />
· Output: 0 to 10 V, 0 to 20 mA, or 4 to 20 mA<br />
· Output signal is adjustable via DIP switch<br />
· OFFSET and SPAN setting is always accessible<br />
Circuit diagram<br />
Type<br />
Cat. no./Qty. p.pck.<br />
Size (L x W x H) with TS 35 x 7.5<br />
Weight<br />
General information<br />
DIN-VDE specifications<br />
Electro-magnetic compatibility<br />
Protection class<br />
Operating temperature<br />
Connection type<br />
Insulation stripping length<br />
Conductor cross-section<br />
Screw-clamp / tension-spring connection<br />
Conversion error<br />
Temperature coefficient<br />
Frequency limit (- 3dB)<br />
Power supply<br />
Input data<br />
Potentiometer<br />
Minimal use of potentiometer<br />
for OFFSET/SPAN adjustment<br />
Remarks:<br />
Output data<br />
Voltage of output signal<br />
Max. voltage of output signal<br />
Load resistance<br />
Current of outputs (adjustable via DIP switch)<br />
Max. output current<br />
Load resistance<br />
Offset<br />
Remarks:<br />
CML-POT-UI<br />
15641.2/1<br />
93.1 x 6.2 x 102.5 mm<br />
66 g<br />
DIN EN 50178:1987; DIN VDE 0110 pollution degree 2, overvoltage category III<br />
CE compliant<br />
IP 20<br />
-20 to +55°C<br />
Screw-clamp/tension-spring connection<br />
12mm/8mm<br />
0.2-2.5mm 2<br />
AWG 22-14<br />
< 0.2% of end value<br />
< 0.02%/K<br />
10 Hz<br />
24 V DC -15% +10%/40 mA<br />
0 to 1 kΩ to 0 to 20 kΩ<br />
60%<br />
first adjust offset, then span<br />
0 to 10 V (default)<br />
approx. 11 V<br />
> 1 kΩ<br />
0 to 20 or 4 to 20 mA (default is 4 to 20 mA)<br />
approx. 22 mA<br />
< 500 Ω<br />
< 10 mV/20 mA<br />
when the current and voltage outputs are used simultaneously, the load resistance must be<br />
> 10 kΩ on the voltage output.<br />