www.schneider-electric.us<br />

Enclosed Starters<br />

TeSys ® D in Metal Enclosures<br />

Refer to Catalog 8502CT9901<br />

TeSys D enclosed full voltage starters are available in Type 1 and Type 12/3R enclosures through 50 hp at 460 V. The<br />

enclosed D-line accepts standard D-Line accessories and all Insta-Kits control units and control power transformer<br />

kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure.<br />

For extra capacity, please refer to your local distributor or nearest Square D/Schneider Electric sales office.<br />

Table 18.69: Enclosed Full Voltage Non-reversing Starters<br />

Max. Horsepower Ratings (AC3)<br />

1 Phase 3 Phase<br />

Auxiliary Contacts Current Rating Catalog Number<br />

Catalog Number<br />

of Contactor<br />

$ Price<br />

$ Price<br />

115 230 200 V 230 V 460 V 575V N.O. N.C. Type 1 Type 12/3R<br />

0.333 1 2 2 5 7.5 1 1 9 LE1D093A62••••• 109. LE1D093A72••••• 175.<br />

0.5 2 3 3 7.5 10 1 1 12 LE1D123A62••••• 137. LE1D123A72••••• 202.<br />

1 3 5 5 10 15 1 1 18 LE1D183A62••••• 153. LE1D183A72••••• 219.<br />

2 3 5 7.5 15 20 1 1 25 LE1D253A62••••• 170. LE1D253A72••••• 235.<br />

2 5 7.5 10 20 25 1 1 32 LE1D323A62••••• 191. LE1D323A72••••• 245.<br />

3 5 10 10 30 30 1 1 40 LE1D403A62••••• 273. LE1D403A72••••• 393.<br />

3 7.5 12 15 40 40 1 1 50 LE1D503A62••••• 300. LE1D503A72••••• 420.<br />

5 10 20 20 40 50 1 1 65 LE1D653A62••••• 393. LE1D653A72••••• 514.<br />

7.5 15 30 30 60 60 1 1 80 LE1D803A62••••• 473. LE1D803A72••••• 610.<br />

Table 18.70: Enclosed Full Voltage Reversing Starters<br />

Max. Horsepower Ratings (AC3) 3 Phase<br />

Auxiliary Contacts On Each<br />

Contactor<br />

Current Rating Catalog Number<br />

Catalog Number<br />

of Contactor<br />

$ Price<br />

200V 230 V 460 V 575 V N.O. N.C. Type 1 Type 12/3R<br />

$ Price<br />

2 2 5 7.5 1 1 9 LE2D093A62••••• 305. LE2D093A72••••• 382.<br />

3 3 7.5 10 1 1 12 LE2D123A62••••• 355. LE2D123A72••••• 453.<br />

5 5 10 15 1 1 18 LE2D183A62••••• 385. LE2D183A72••••• 483.<br />

5 7.5 15 20 1 1 25 LE2D253A62••••• 415. LE2D253A72••••• 513.<br />

7.5 10 20 25 1 1 32 LE2D323A62••••• 464. LE2D323A72••••• 573.<br />

10 10 30 30 1 1 40 LE2D403A62••••• 655. LE2D403A72••••• 819.<br />

12 15 40 40 1 1 50 LE2D503A62••••• 710. LE2D503A72••••• 874.<br />

20 20 40 50 1 1 65 LE2D653A62••••• 900. LE2D653A72••••• 1030.<br />

30 30 60 60 1 1 80 LE2D803A62••••• 1248. LE2D803A72••••• 1412.<br />

Table 18.71: Catalog Number Nomenclature<br />

Catalog Number Example:<br />

Base Catalog Number<br />

Wiring Method<br />

Control Power Transformer f<br />

Contactor/Starter Coil Voltage g<br />

Coil Frequency h<br />

Overload Relay Type j<br />

Overload Relay Range i<br />

fControl Power Transformer<br />

Add price from page 18-23. Select letter for primary<br />

voltage of CPT:<br />

Voltage No Transformer used 208 240 480 600<br />

Code O a L M T X<br />

a Letter O, not zero.<br />

Note: If control transformer is used, the only options available are 24 or 120<br />

volts as the secondary of the transformer. Also, DC voltages are not<br />

available when control power transformer is used.<br />

gContactor/Starter Coil Voltage<br />

Select coil voltage from table:<br />

Voltage 24 120 208 240 480 600<br />

AC B G L U T X<br />

DC B — — — — —<br />

hCoil Frequency<br />

Select:<br />

7 = dual frequency coils (50/60 Hz.)<br />

6 = 60 Hz.<br />

D=DC<br />

Note: For 9 to 65 A contactors, only dual frequency coils are available; 80<br />

A contactors, the 24 V to 240 V coils are dual frequency only (50/60<br />

Hz.). The 480 V to 600 V coils are 60 Hz. only. See catalog for other<br />

restrictions.<br />

jOverload relay type<br />

LE1D093A62 O G 7 1 07<br />

iOverload Relay Range<br />

Select code from the below:<br />

b<br />

c<br />

Note:<br />

Code<br />

Range<br />

For use on<br />

Contactors<br />

$ Price Adder<br />

01 0.1–0.16 D09–D32b 60.<br />

02 0.16–0.25 D09–D32b 60.<br />

03 0.25–0.40 D09–D32b 60.<br />

04 0.40–0.63 D09–D32b 60.<br />

05 0.63–1.0 D09–D32b 60.<br />

06 1.0–1.6 D09–D32b 60.<br />

07 1.6–2.5 D09–D32b 60.<br />

08 2.5–4 D09–D32 60.<br />

10 4–6 D09–D32 60.<br />

12 5.5–8 D09–D32 60.<br />

13 9–13 D40, D50, D65 107.<br />

14 7–10 D09–D32 62.<br />

16 9–13 D12–D32 62.<br />

18 12–18 D40, D50, D65 107.<br />

21 12–18 D18–D32 62.<br />

16–24 D25–D32b 62.<br />

22<br />

17–25 D25–D32c 62.<br />

17–25 D80 107.<br />

25 17–25 D40, D50, D65 107.<br />

30 23-28 D25–D32c 73.<br />

32 23–32 D25–D32 73.<br />

32 23–32 D40, D50, D65 107.<br />

40 30–40 D40, D50, D65 107.<br />

50 37–50 D40, D50, D65 107.<br />

53 30–38 D80 107.<br />

55 30–40 D80 107.<br />

57 37–50 D80 107.<br />

59 48–65 D80 107.<br />

61 55–70 D65–D80 107.<br />

63 63–80 D65–D80 107.<br />

65 48–65 D40, D50, D65 107.<br />

Available for Class 10 only.<br />

Available for Class 20 only.<br />

If no overload relay is required, leave this portion of the catalog blank.<br />

Add appropriate Price Adder to the base price of the starter.<br />

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-48<br />

IEC CONTACTORS AND<br />

18 STARTERS<br />

Select:<br />

0 = No overload relay<br />

1 = Class 10 Trip<br />

2 = Class 20 Trip<br />

© 2009 Schneider Electric<br />