26.01.2015 Views

Orthodontic Screw System Orthodontic Screw System - Osstem.

Orthodontic Screw System Orthodontic Screw System - Osstem.

Orthodontic Screw System Orthodontic Screw System - Osstem.

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Osstem</strong> <strong>Osstem</strong> <strong>Orthodontic</strong> <strong>Screw</strong> Catalog & User Manual<br />

New <strong>Orthodontic</strong> Design Quality <strong>Screw</strong> Feature SPEC<br />

Good Initial Stability<br />

Application Case by <strong>Orthodontic</strong> <strong>Screw</strong> Diameter<br />

The initial stability of the orthodontic screw is mainly provided<br />

by the cortical bone. With this new product, the initial stability is<br />

effectively improved by increasing the taper Body. ● When the approach is difficult due to the narrow space between<br />

Therefore, sufficient final torque for placement and less the possibility dental roots of the maxillary/mandibular anterior teeth<br />

of displacement<br />

∅1.4<br />

can be achieved when applied with orthodontic ※ The ∅1.4 force. size has limited strength due to its small size.<br />

Pilot drill placement is recommended to prevent fracture.<br />

50<br />

Resistance against <strong>Orthodontic</strong> Forces<br />

Resistance of the thread against external load<br />

To use orthodontic screws as a stable anchorage, the screw thread<br />

30<br />

and bone must have sufficient resistance against orthodontic forces.<br />

New<br />

The screw thread and body shape of the new product are designed<br />

20<br />

to be highly rigid against orthodontic forces.<br />

Conventional<br />

● Where sufficient space can be obtained10<br />

Competitor<br />

● When sufficient initial stability can be obtained from normal bone quality<br />

∅1.6<br />

Load(N)<br />

40<br />

0<br />

0.00 0.05<br />

0.10 0.15 0.20<br />

Displacement(mm)<br />

Stress Distribution<br />

The body and thread of the new orthodontic screw are designed to<br />

facilitate stress distribution.<br />

Thus, long-term orthodontic force does not give excessive ● Where stress sufficient to space can be obtained<br />

the bone with the new orthodontic screw<br />

● When high initial stability is required from soft bone quality<br />

∅1.8<br />

Conventional : 35.3Mpa<br />

New : 23.8Mpa<br />

Enhanced Body Strength<br />

80<br />

70<br />

Comparison of Fracture Strength of <strong>Orthodontic</strong> <strong>Screw</strong>s<br />

New<br />

The fracture strength is improved by increasing the upper diameter.<br />

The strength is far superior to the conventional products to improve<br />

the safety of the placement.<br />

However, the Ø1.4 diameter size has low body strength<br />

So requires careful placement.<br />

Torque(Ncm)<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

Competitor<br />

Conventional<br />

0<br />

0 1 2 3 4 5 6 7 8 9 10<br />

-10<br />

Placement Depth<br />

03 07