Orthodontic Screw System Orthodontic Screw System - Osstem.
Orthodontic Screw System Orthodontic Screw System - Osstem.
Orthodontic Screw System Orthodontic Screw System - Osstem.
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Osstem</strong> <strong>Osstem</strong> <strong>Orthodontic</strong> <strong>Screw</strong> Catalog & User Manual<br />
New Surgical Design Instrument Quality Feature<br />
Good Initial Stability<br />
Drill<br />
D ∅1.3 ∅1.5<br />
The initial stability of the orthodontic screw is mainly provided<br />
by the cortical bone. With this new product, the initial stability is<br />
Code OSODR130C OSODR150C<br />
● Laser Marking: indicated with 6 / 8 / 10 / 12mm<br />
effectively improved by increasing the taper Body.<br />
● ∅1.3 Drill - use for the placement of ∅1.4 or ∅1.6 screws<br />
Therefore, sufficient final torque for placement and less possibility ● ∅1.5 Drill - use for the placement of ∅1.8 screw<br />
● Recommended drilling speed: 800rpm (high speed)<br />
of displacement can be achieved when applied with orthodontic force.<br />
● It is recommended to remove some cortical bone by drilling before<br />
placement. If the cortical bone is Resistance very thick, of the the thread drilling against depth external should loadbe<br />
Resistance against <strong>Orthodontic</strong> Forces<br />
the same as the length of the 50 screw<br />
6<br />
To use orthodontic screws as a stable anchorage, the screw thread<br />
and bone must have sufficient Dresistance against orthodontic forces.<br />
The screw thread and body shape of the new product are designed<br />
to be highly rigid against orthodontic forces.<br />
Universal Handle<br />
Stress Distribution<br />
8<br />
29.4<br />
10 12 14<br />
Load(N)<br />
40<br />
30<br />
20<br />
10<br />
New<br />
Conventional<br />
Competitor<br />
Code<br />
0<br />
0.00 0.05 0.10OUH<br />
Displacement(mm)<br />
0.15 0.20<br />
● Use by coupling with the driver tip. The middle part of the handle is anti-slip<br />
processed for easier placement<br />
The body and thread of the new orthodontic screw are designed to<br />
facilitate stress distribution.<br />
Thus, long-term orthodontic force does not give excessive stress to<br />
the bone with the new orthodontic screw<br />
30<br />
100<br />
Conventional : 35.3Mpa<br />
New : 23.8Mpa<br />
Driver Tip<br />
Enhanced Body Strength<br />
80<br />
Hex<br />
Type<br />
Cross<br />
70 Short LongNew<br />
L 48 70 69<br />
The fracture strength is improved by increasing the upper diameter.<br />
60<br />
Code OSDTS OSDT OCDT<br />
50<br />
Competitor<br />
The strength is far superior to the conventional products to improve<br />
● Use for the placement of orthodontic screws by coupling with the<br />
40<br />
the safety of the placement.<br />
Universal Handle<br />
Conventional<br />
30<br />
However, the Ø1.4 diameter size has low<br />
L<br />
body strength<br />
● The set consists of Hex and Cross types. Use the Hex type for applying<br />
torque, and use Cross 20 type for correcting the through hole path of the<br />
So requires careful placement.<br />
screw part<br />
Torque(Ncm)<br />
10<br />
Comparison of Fracture Strength of <strong>Orthodontic</strong> <strong>Screw</strong>s<br />
(Hex)<br />
(Hex)<br />
(Cross)<br />
0<br />
(Caution) Do not apply excessive 0 1torque 2 with 3 the 4 cross 5 6type 7 driver 8 9 10<br />
-10<br />
Placement Depth<br />
03 09