27.01.2015 Views

Single StEP Columns - Thomson Instrument Company

Single StEP Columns - Thomson Instrument Company

Single StEP Columns - Thomson Instrument Company

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

US Patents & UK Patent<br />

* See Below *<br />

FLASH COLUMNS<br />

SINGLE <strong>StEP</strong> <strong>Columns</strong> range from 4g-300g<br />

and are rated to 100 PSI +<br />

4g<br />

Below column: Loading Amount<br />

2.6g-4.1g<br />

80g<br />

4g<br />

25g<br />

U.S. PATENT # 7,138,061 FLASH COLUMNS<br />

Simple Screw Top - Easily Liquid or Dry Load<br />

Directly on <strong>Columns</strong><br />

Works on Biotage, Isco, and SINGLE <strong>StEP</strong> Pumps<br />

Available in many choices of Normal and<br />

Reversed Phase Sorbents<br />

80g<br />

40g<br />

40g<br />

700mg-4.9g<br />

25g<br />

90g<br />

4.2g-5.6mg<br />

U.S. PATENT # 7,138,061 FLASH COLUMNS<br />

1.5g-2.5g<br />

12g<br />

12g<br />

90g<br />

U.S. PATENT # 7,138,061 FLASH COLUMNS<br />

Headspace Frits<br />

300mg-600mg<br />

SINGLE <strong>StEP</strong> PUMP TM<br />

Biotage R Machines<br />

Isco 16 R Channel<br />

110g<br />

U.S. PATENT # 7,138,061 FLASH COLUMNS<br />

160g<br />

U.S. PATENT # 7,138,061 FLASH COLUMNS<br />

240g<br />

U.S. PATENT # 7,138,061 FLASH COLUMNS<br />

U.S. PATENT # 7,138,061 FLASH COLUMNS<br />

300g<br />

Band can be seen by Color or UV on the Column<br />

High Resolution Packing<br />

Direct Replacement for Glass <strong>Columns</strong><br />

U.S. Patent 7,138,061, 7,381,327 and 7,410,571, and other Patents Pending. UK Patent 2413972<br />

<strong>Thomson</strong> <strong>Instrument</strong> <strong>Company</strong><br />

Phone: 800.541.4792 or 760.757.8080 e-mail: folks@htslabs.com<br />

www.htslabs.com<br />

<strong>Thomson</strong> <strong>Instrument</strong> <strong>Company</strong> is not affiliated with Biotage A.B., E.M. Sciences, or Isco/Teledyne Inc.<br />

R<br />

R<br />

R


www.htslabs.com<br />

U.S. PATENT # 7,138,061<br />

FLASH COLUMNS<br />

The SINGLE <strong>StEP</strong> <strong>Columns</strong> are versatile enough to be used on<br />

any machine. SINGLE <strong>StEP</strong> columns are clear, so that one may see<br />

their bands or use a UV light to see their bands when using it in<br />

the hood (Darkened Hood). The SINGLE <strong>StEP</strong> columns have luer<br />

fittings which allow for attachment to any machine including:<br />

Biotage©, Isco®, SINGLE <strong>StEP</strong>© Pump units, etc. SINGLE <strong>StEP</strong> columns<br />

fit into the slots of Isco® Flash Machines. SINGLE <strong>StEP</strong> columns fit<br />

onto all Biotage Horizons , manual, SP-1 and SP-4 by luer fittings,<br />

eliminating the need for compression fittings. SINGLE <strong>StEP</strong> <br />

columns can be easily pre-equilibrated. SINGLE <strong>StEP</strong> columns have<br />

an added advantage that they allow direct injection as close to the<br />

sorbent bed as possible, either by liquid or dry loading, directly to<br />

the column. SINGLE <strong>StEP</strong> <strong>Columns</strong> are easy to use whether you<br />

have expensive equipment or you are just starting a lab.<br />

The SINGLE <strong>StEP</strong>TM columns allow for liquid or dry loading directly<br />

on the column. SINGLE <strong>StEP</strong> columns can be liquid loaded easily by<br />

pouring the material on top of the column, then placing on the cap,<br />

and taking a 10mL-20mL (plastic) syringe and pushing the liquid onto<br />

the column. Scientists also allow for more polar loading solvents such<br />

as DCM-Methanol to evaporate by allowing the column to air dry in<br />

the hood. This is suggested to avoid streaking when starting Hexane<br />

or less polar solvents. Dry loading has been simplified for the Isco by<br />

the SINGLE <strong>StEP</strong> columns. Because you do not need a 2nd column<br />

on top, which can cause precipitation in the line, and can cause a<br />

system “Crash”. SINGLE <strong>StEP</strong> columns have served as robust columns<br />

that can be used on many different types of machines for any<br />

Flash or MPLC need.<br />

<strong>Thomson</strong> <strong>Instrument</strong> <strong>Company</strong><br />

Phone: 800.541.4792 or 760.757.8080 e-mail: folks@htslabs.com<br />

<strong>Thomson</strong> <strong>Instrument</strong> <strong>Company</strong> is not affiliated with Biotage A.B., E.M. Sciences, or Isco/Teledyne Inc.<br />

R<br />

R<br />

R

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!