Single StEP Columns - Thomson Instrument Company
Single StEP Columns - Thomson Instrument Company
Single StEP Columns - Thomson Instrument Company
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
US Patents & UK Patent<br />
* See Below *<br />
FLASH COLUMNS<br />
SINGLE <strong>StEP</strong> <strong>Columns</strong> range from 4g-300g<br />
and are rated to 100 PSI +<br />
4g<br />
Below column: Loading Amount<br />
2.6g-4.1g<br />
80g<br />
4g<br />
25g<br />
U.S. PATENT # 7,138,061 FLASH COLUMNS<br />
Simple Screw Top - Easily Liquid or Dry Load<br />
Directly on <strong>Columns</strong><br />
Works on Biotage, Isco, and SINGLE <strong>StEP</strong> Pumps<br />
Available in many choices of Normal and<br />
Reversed Phase Sorbents<br />
80g<br />
40g<br />
40g<br />
700mg-4.9g<br />
25g<br />
90g<br />
4.2g-5.6mg<br />
U.S. PATENT # 7,138,061 FLASH COLUMNS<br />
1.5g-2.5g<br />
12g<br />
12g<br />
90g<br />
U.S. PATENT # 7,138,061 FLASH COLUMNS<br />
Headspace Frits<br />
300mg-600mg<br />
SINGLE <strong>StEP</strong> PUMP TM<br />
Biotage R Machines<br />
Isco 16 R Channel<br />
110g<br />
U.S. PATENT # 7,138,061 FLASH COLUMNS<br />
160g<br />
U.S. PATENT # 7,138,061 FLASH COLUMNS<br />
240g<br />
U.S. PATENT # 7,138,061 FLASH COLUMNS<br />
U.S. PATENT # 7,138,061 FLASH COLUMNS<br />
300g<br />
Band can be seen by Color or UV on the Column<br />
High Resolution Packing<br />
Direct Replacement for Glass <strong>Columns</strong><br />
U.S. Patent 7,138,061, 7,381,327 and 7,410,571, and other Patents Pending. UK Patent 2413972<br />
<strong>Thomson</strong> <strong>Instrument</strong> <strong>Company</strong><br />
Phone: 800.541.4792 or 760.757.8080 e-mail: folks@htslabs.com<br />
www.htslabs.com<br />
<strong>Thomson</strong> <strong>Instrument</strong> <strong>Company</strong> is not affiliated with Biotage A.B., E.M. Sciences, or Isco/Teledyne Inc.<br />
R<br />
R<br />
R
www.htslabs.com<br />
U.S. PATENT # 7,138,061<br />
FLASH COLUMNS<br />
The SINGLE <strong>StEP</strong> <strong>Columns</strong> are versatile enough to be used on<br />
any machine. SINGLE <strong>StEP</strong> columns are clear, so that one may see<br />
their bands or use a UV light to see their bands when using it in<br />
the hood (Darkened Hood). The SINGLE <strong>StEP</strong> columns have luer<br />
fittings which allow for attachment to any machine including:<br />
Biotage©, Isco®, SINGLE <strong>StEP</strong>© Pump units, etc. SINGLE <strong>StEP</strong> columns<br />
fit into the slots of Isco® Flash Machines. SINGLE <strong>StEP</strong> columns fit<br />
onto all Biotage Horizons , manual, SP-1 and SP-4 by luer fittings,<br />
eliminating the need for compression fittings. SINGLE <strong>StEP</strong> <br />
columns can be easily pre-equilibrated. SINGLE <strong>StEP</strong> columns have<br />
an added advantage that they allow direct injection as close to the<br />
sorbent bed as possible, either by liquid or dry loading, directly to<br />
the column. SINGLE <strong>StEP</strong> <strong>Columns</strong> are easy to use whether you<br />
have expensive equipment or you are just starting a lab.<br />
The SINGLE <strong>StEP</strong>TM columns allow for liquid or dry loading directly<br />
on the column. SINGLE <strong>StEP</strong> columns can be liquid loaded easily by<br />
pouring the material on top of the column, then placing on the cap,<br />
and taking a 10mL-20mL (plastic) syringe and pushing the liquid onto<br />
the column. Scientists also allow for more polar loading solvents such<br />
as DCM-Methanol to evaporate by allowing the column to air dry in<br />
the hood. This is suggested to avoid streaking when starting Hexane<br />
or less polar solvents. Dry loading has been simplified for the Isco by<br />
the SINGLE <strong>StEP</strong> columns. Because you do not need a 2nd column<br />
on top, which can cause precipitation in the line, and can cause a<br />
system “Crash”. SINGLE <strong>StEP</strong> columns have served as robust columns<br />
that can be used on many different types of machines for any<br />
Flash or MPLC need.<br />
<strong>Thomson</strong> <strong>Instrument</strong> <strong>Company</strong><br />
Phone: 800.541.4792 or 760.757.8080 e-mail: folks@htslabs.com<br />
<strong>Thomson</strong> <strong>Instrument</strong> <strong>Company</strong> is not affiliated with Biotage A.B., E.M. Sciences, or Isco/Teledyne Inc.<br />
R<br />
R<br />
R