GRAFIK Systems<br />

<strong>GRX</strong>-<strong>IRPS</strong>-<strong>WH</strong><br />

<strong>Infrared</strong> <strong>Transmitter</strong>/<strong>Receiver</strong> <strong>Pair</strong><br />

System Diagram<br />

1 2 3 4 C 1 2 3 4 5 1 2 3 C4<br />

5<br />

LUTRON LUTRON<br />

MUX LINK INPUTS OUTPUTS<br />

<strong>GRX</strong>-12VDC<br />

R<br />

Job Name:<br />

Job Number:<br />

<strong>GRX</strong>-<strong>IRPS</strong><br />

<strong>Transmitter</strong><br />

R<br />

COOPERSBURG, PA 18036<br />

DIP SWITCH SETTINGS (1-4) 0 = ON; 1 = OFF<br />

1 2 3 4 ADDRESS 1 2 3 4 ADDRESS 1 2 3 4 ADDRESS 1 2 3 4 ADDRESS<br />

0 0 0 0 1 0 1 0 0 5 1 0 0 0 9 1 1 0 0 13<br />

0 0 0 1 2 0 1 0 1 6 1 0 0 1 10 1 1 0 1 14<br />

0 0 1 0 3 0 1 1 0 7 1 0 1 0 11 1 1 1 0 15<br />

0 0 1 1 4 0 1 1 1 8 1 0 1 1 12 1 1 1 1 16<br />

DIP SWITCH SETTINGS (5-8 )<br />

TYPE CONFIGURATION<br />

DIP SETTING<br />

4S CONTROL SCENES 1-4, MAINTAIN OUTPUTS 5 ON 6 ON<br />

SCENES 5-8, MAIN TAIN OUTPUTS 5 OFF 6 ON<br />

7 ON 8 ON SCENES 9-12, MAIN TAIN OUTPUTS 5 ON 6 OFF<br />

SCENES 13-16, MAIN TAIN OUTPUTS 5 OFF 6 OFF<br />

4S CONTROL SCENES 1-4, MOMENT ARY OUTPUTS 5 ON 6 ON<br />

SCENES 5-8, MOMENT ARY OUTPUTS 5 OFF 6 ON<br />

7 ON 8 OFF SCENES 9-12, MOMENT ARY OUTPUTS 5 ON 6 OFF<br />

SCENES 13-16, MOMENT ARY OUTPUTS 5 OFF 6 OFF<br />

4Q CONTROL SEQUENCE 1-4, MAIN TAIN INPUTS 5 OFF 6 ON<br />

SEQUENCE 1-4, MOMENT ARY INPUTS 5 ON 6 ON<br />

7 OFF 8 OFF SEQUENCE 5-16, MAIN TAIN INPUTS 6 OFF 6 OFF<br />

SEQUENCE 5-16, MOMENT ARY INPUTS 6 ON 6 OFF<br />

4PS CONTROL PARTITION STATUS, MOMENTARY INPUTS 5 ON 6 ON<br />

7 OFF 8 ON PARTITION STATUS, MAINTAINED INPUTS 5 OFF 6 ON<br />

SPECIAL OCCUPANCY SENSOR - SCENE 1 & FOF 5 ON 6 OFF<br />

CONTROL OCCUPANCY SENSOR - OFF ONL Y 5 OFF 6 OFF<br />

7 OFF 8 ON<br />

1 2 3 4 5 6 7 8<br />

1 2 3 4 C 1 2 3 4 5 1 2 3 C4<br />

5<br />

MUX LINK INPUTS OUTPUTS<br />

COM<br />

+V<br />

MUX<br />

MUX<br />

PROGRAM<br />

SWITCH<br />

COM<br />

<strong>GRX</strong>-AV<br />

INTERFACE CONTROL<br />

SELV(CLASS 2:USA)<br />

ON<br />

OFF<br />

SELV (CLASS 2:USA)<br />

1 2 3 4 5 6 7 8<br />

SPECIFICATION SUBMITTAL<br />

R<br />

ADDRESS<br />

CONFIG.<br />

TYPE<br />

COM<br />

Model Numbers:<br />

<strong>GRX</strong>-<strong>IRPS</strong>-<strong>WH</strong><br />

<strong>GRX</strong>-<strong>IRPS</strong><br />

<strong>Receiver</strong><br />

Room A Room B<br />

Partition<br />

<strong>GRX</strong>/OMX-AV<br />

Wallstations Wallstations<br />

Class 2/PELV Control Link<br />

Accessories<br />

irps-1 06.16.04<br />

Description<br />

<strong>Infrared</strong> transmitter/receiver pair automatically<br />

coordinates lighting preset functions in areas<br />

with partitions, such as partitioned meeting<br />

rooms or ballrooms. Sensors may be used with<br />

GRAFIK Eye 3000 or 4000 Systems as well as<br />

GRAFIK 5000, 6000, or 7000 Systems.<br />

• Automatically combines lighting preset functions<br />

when partition is open creating one large space.<br />

• Lighting preset functions become independent<br />

as partition is closed creating several smaller<br />

spaces.<br />

• Sensors require additional Lutron interface<br />

(<strong>GRX</strong>-AV or OMX-AV) and power supply (<strong>GRX</strong>-<br />

12VDC) for proper operation.<br />

Ceiling<br />

Page


GRAFIK Systems<br />

Specifications<br />

R<br />

Job Name:<br />

Job Number:<br />

SPECIFICATION SUBMITTAL<br />

Model Numbers:<br />

<strong>GRX</strong>-<strong>IRPS</strong>-<strong>WH</strong><br />

Power<br />

• Operating voltage: Low-voltage Class 2 (PELV) 12 V DC<br />

from <strong>GRX</strong>-12VDC plug-in power supply (ordered<br />

separately). One <strong>GRX</strong>-12VDC can supply power to five<br />

sensor transmitter/receiver pairs.<br />

• <strong>Transmitter</strong> and receiver have reverse polarity and shortcircuit<br />

protection.<br />

Sensor Status Indicator<br />

• <strong>Receiver</strong> includes an LED indicator that assists in sensor<br />

alignment during installation and provides sensor<br />

operating status.<br />

System Capacity<br />

• Each <strong>GRX</strong>-AV or OMX-AV Interface (ordered separately)<br />

can accommodate up to five transmitter/receiver pairs<br />

for five different moveable walls.<br />

Connection<br />

Wire leads provided.<br />

Finish<br />

• White painted metal.<br />

Environment<br />

32-104°F (0-40°C). Relative humidity less than 90%<br />

non-condensing.<br />

Mounting<br />

Surface mount indoors only.<br />

Accessories<br />

irps-2 06.16.04<br />

Page


GRAFIK Systems<br />

Dimensions and Mounting<br />

R<br />

Job Name:<br />

Job Number:<br />

SPECIFICATION SUBMITTAL<br />

Model Numbers:<br />

<strong>GRX</strong>-<strong>IRPS</strong>-<strong>WH</strong><br />

• <strong>Receiver</strong> and transmitter surface mount in 1-gang U.S.<br />

wallboxes 3.5" (89mm) deep, mounted facedown from<br />

the ceiling. Indoors only.<br />

• The sensors must be mounted in a position where the<br />

partition separates the transmitter and receiver when<br />

the partition is closed.<br />

• <strong>Transmitter</strong> and receiver may be located no more than<br />

8 ft. (243mm) apart.<br />

• Adjustable mounting brackets allow easy alignment<br />

during installation.<br />

• Wires feed through the back of the transmitter/receiver.<br />

Side View<br />

<strong>GRX</strong>-<strong>IRPS</strong>-<strong>WH</strong><br />

<strong>Transmitter</strong><br />

Top View<br />

Standard single-gang U.S. wallbox<br />

mounted facedown and flush with<br />

ceiling surface (typical of two).<br />

Partition<br />

8 ft. (243mm) maximum)<br />

1.25 in. (31.75mm)<br />

<strong>GRX</strong>-<strong>IRPS</strong>-<strong>WH</strong><br />

<strong>Receiver</strong><br />

Accessories<br />

Ceiling<br />

Single gang wallbox<br />

(typical of two)<br />

Wallbox mounting<br />

line of center<br />

irps-3 06.16.04<br />

Page