MINIKITS<br />
The MINIKITS are designed <strong>for</strong> rapid water testing. Most of the<br />
MINIKITS are based on titrimetric methods.<br />
Extremely easy to use, <strong>and</strong> available <strong>for</strong> a wide variety of testing<br />
parameters, the MINIKITS utilize tablet reagent that deliver<br />
an exact dosing, making them more accurate <strong>and</strong> easier to use<br />
than traditional liquid drop tests.<br />
Features<br />
• Easy to use with exact<br />
reagent dosing<br />
• Cost effective<br />
• Tablet reagents have a<br />
guaranteed shelf life of 5<br />
years<br />
• Easy <strong>and</strong> safe storage<br />
Tablet Count Method:<br />
In the tablet count method, the liquid titration solution <strong>and</strong><br />
indicator are replaced by <strong>Orbeco</strong>-<strong>Hellige</strong> tablet reagents. A<br />
specified number of tablets are added to a defined sample<br />
volume until a chemically induced color change takes place. The<br />
concentration of the parameter being measured is calculated<br />
from the number of tablets required. The measuring range can<br />
be exp<strong>and</strong>ed by varying the sample volume.<br />
Speed Test:<br />
The speed test is based on reverse titration. After adding a<br />
reagent tablet to a calibrated test tube, the water sample is<br />
added slowly until the color of the solution changes (i.e. from red<br />
to blue). The user can then read the result of the liquid level.<br />
Turbidity Method:<br />
A two-section calibrated tube is filled with sample <strong>and</strong> a reagent<br />
tablet is added. The reagent creates a level of turbidity that<br />
is proportional to the concentration of the parameter being<br />
measured. The inner tube, which has a black dot on its base, is<br />
lowered until the dot is obscured by the turbidity. The result is<br />
read from the water level in the inner tube.<br />
Parameter Test Kit P/N Method Range Replacement<br />
(ppm / mg/l)<br />
Reagents P/N<br />
Alkalinity, (Total) L414440 Speed Test 20-800, ≈ 0.4 - 16 mmol/L RT557-0<br />
Alkalinity-M L414130 Tablet Count 10-500, ≈ 0.1 - 5 mmol/L RT511-0<br />
Calcium Hardness L414460 Speed Test 20-800, ≈ 0.4 - 16 mmol/L RT558-0<br />
Calcium Hardness L414160 Tablet Count 10-500, ≈ 0.1 - 5 mmol/L RT519-1<br />
Chloride L414180 Tablet Count 5-500 RT513-1<br />
Cyanuric Acid L414220 Turbidity 20-200 RT132-0<br />
Hardness (Total) L414450 Speed Test 20-800,≈ 0.4-16 mmol/L RT559-0<br />
Hardness (Total) L414240 Tablet Count 5-500, ≈ 0.05-5 mmol/L RT516-1<br />
12<br />