LG IV5 SERIES PARAMETER LIST - Aybey Elektronik
LG IV5 SERIES PARAMETER LIST - Aybey Elektronik
LG IV5 SERIES PARAMETER LIST - Aybey Elektronik
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>LG</strong> <strong>IV5</strong> <strong>SERIES</strong> <strong>PARAMETER</strong> <strong>LIST</strong><br />
<strong>PARAMETER</strong>S EXPLANATION SETTINGS<br />
I/O-01 HIGH SPEED INPUT SPEED L<br />
I/O-02 LOW SPEED INPUT SPEED M<br />
I/O-03 INSPECTION INPUT SPEED H<br />
I/O-05 TIMER INPUT<br />
I/O-41 TIMER OUT<br />
I/O-55 WAIT TIME BEFORE ENERGIZING BRAKE 0.5<br />
I/O-56 WAIT TIME BEFORE RELEASING BRAKE 1.0<br />
PAR-07 MOTOR POWER (KW) SET<br />
PAR-10 ENCODER PPR SET<br />
PAR-17 MOTOR RPM SET<br />
PAR-18 MOTOR VOLTAGE (V) SET<br />
PAR-19 NUMBER OF MOTOR POLES SET<br />
PAR-20 MOTOR EFFICIENCY % SET<br />
PAR-21 MOTOR RATED SLIP SET<br />
PAR-22 MOTOR RATED CURRENT SET<br />
FUN-01 RUN/STOP COMMAND SOURCE SELECTION TERMINAL 1<br />
FUN-04 MAX. MOTOR SPEED 1550<br />
FUN-13 HIGH SPEED RPM 1400<br />
FUN-14 SLOW SPEED RPM 100<br />
FUN-16 INSPECTION SPEED RPM 400<br />
FUN-36 S RATIO IN ACCELERATION START 30<br />
FUN-37 S RATIO IN ACCELERATION END 25<br />
FUN-38 S RATIO IN DECELERATION START 25<br />
FUN-39 S RATIO IN DECELERATION END 30<br />
FUN-40 ACCELERATION TIME 2.5<br />
FUN-41 DECELERATION TIME 2<br />
FUN-52 PRE-EXCITATION TIME 500<br />
FUN-53 HOLD TIME 500<br />
FUN-59 RESTART AFTER FAULT RESET YES<br />
FUN-60 NUMBER OF AUTO RESTART TRY 3<br />
FUN-61 DELAY TIME BEFORE AUTO RESTART 3<br />
PAR-11 ENCODER DIRECTION SETTING<br />
AUTO-TUNING PROCEDURE<br />
A-Phase Lead<br />
1.Be sure that motor encoder is connected.Set J1,J2 jumpers according<br />
to encoder supply voltage.<br />
2.Set motor parameters before Auto-tuning.<br />
3.Connect motor cables directly to inverter.If there are K1-K2 contactor between motor<br />
and inverter , pres them manually.<br />
4.Set PAR-23 as STANDSTILL or ROTATIONAL.AYBEY suggests ROTATIONAL<br />
Auto-tuning by releasing ropes.<br />
5.Open brake manually and hold it open until the end of Auto-tuning procedure.<br />
6.Set PAR-24 as ALL1 and pres ENTER.If PAR-23=ROTATIONAL motor will rotate<br />
in a short time.<br />
7.When you see NONE on screen, it means procedure completed successfully.
H<br />
G<br />
F<br />
E<br />
D<br />
C<br />
B<br />
A<br />
FUN-13<br />
FUN-14<br />
FX/RX<br />
P1<br />
P2<br />
BRAKE (KF)<br />
CONTACTOR<br />
MAIN (K1-K2)<br />
CONTACTOR<br />
<strong>LG</strong>-iV5<br />
INVERTER<br />
(I/O) BOARD<br />
OC<br />
LD<br />
1<br />
Frequency<br />
JP4 JP5<br />
(B-) PULSE<br />
(B) PULSE<br />
(A-) PULSE<br />
(A) PULSE<br />
GND(0V)<br />
SUPPLY(5V)<br />
ENCODER<br />
5V Line Driver<br />
FUN-21: Dwell Speed<br />
FUN-52<br />
I/O-55<br />
FUN-16<br />
FX/RX<br />
P3<br />
BRAKE (KF)<br />
CONTACTOR<br />
MAIN (K1-K2)<br />
CONTACTOR<br />
B-<br />
PB/B+<br />
A-<br />
PA/A+<br />
GE/5G<br />
PE<br />
5G<br />
PG<br />
I/O-55<br />
FUN-36<br />
FUN-21: Dwell Speed<br />
2<br />
FUN-37<br />
FUN-38<br />
This document is a sample for applications. All information contained in<br />
these materials are subject to change by <strong>Aybey</strong> <strong>Elektronik</strong> without notice.<br />
<strong>Aybey</strong> <strong>Elektronik</strong> assumes no responsibility for any damage, liability, or<br />
other loss rising from these inaccuracies or errors.<br />
1 2 3 4<br />
3<br />
FUN-39<br />
(a) (b)<br />
FUN-40 : Acceleration time FUN-41 : Decelaration time (a)+(b)<br />
FUN-22<br />
Frequency<br />
JP2<br />
5V<br />
12V<br />
15V<br />
FUN-52<br />
FUN-22<br />
<strong>LG</strong>-iV5<br />
INVERTER<br />
(I/O) BOARD<br />
OC<br />
LD<br />
JP4 JP5<br />
ENCODER<br />
10-30V Open<br />
Collector<br />
B-<br />
PB/B+<br />
A-<br />
PA/A+<br />
GE/5G<br />
PE<br />
5G<br />
(A) PULSE<br />
GND(0V)<br />
SUPPLY(15V)<br />
PG<br />
JP2<br />
5V<br />
12V<br />
15V<br />
(B) PULSE<br />
NORMAL TRAVEL<br />
INSPECTION TRAVEL<br />
ENCODER CONNECTIONS<br />
<strong>LG</strong> iV5 ENCODER <strong>PARAMETER</strong>S<br />
PAR-10 : NUMBER OF ENCODER PULSE (P/R)<br />
PAR-11 : ENCODER DIRECTION SETTING (A&B)<br />
PAR-14 : ENCODER ERROR DETECTION TIME (1.5sn)<br />
IMPORTANT!<br />
Set J2-J4-J5 jumpers according to used encoder type<br />
I/O-56<br />
Time<br />
<strong>LG</strong> iV5 <strong>SERIES</strong> INVERTER<br />
CLOSED LOOP OPERATING DIAGRAM<br />
<strong>SERIES</strong> <strong>LG</strong> DRW. M. AKKUŞ<br />
AYBEY<br />
PROJ. <strong>LG</strong>01 APPRV. M. AYBEY<br />
ELEKTRONİK<br />
REV. 00 DATE 15 FEB 07<br />
4<br />
FUN-53: Hold Time<br />
Time<br />
F/7.5.5.02.37<br />
H<br />
G<br />
F<br />
E<br />
D<br />
C<br />
B<br />
A