here - BioCision
here - BioCision
here - BioCision
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Product Overview<br />
April 2014
About <strong>BioCision</strong><br />
Page<br />
“The lack of standardized, high-quality biospecimens has been<br />
widely recognized as one of the most significant roadblocks to the<br />
progress of cancer research.”<br />
- NIH / NCI / BBRB<br />
Develop products to address unmet standardization needs in preanalytical<br />
sample handling, processing, storage and transport<br />
<strong>BioCision</strong> products improve pre-analytical standardization of<br />
temperature-sensitive bio-medical samples:<br />
• Day to day<br />
• User to user<br />
• Lab to lab<br />
• Site to site<br />
2
Consistent. Reproducible. Standardized.<br />
Sample Temperature Management<br />
CoolRack ® and CoolBox for<br />
reproducible preparation of<br />
temperature-sensitive samples<br />
Cell Cryopreservation<br />
CoolCell products for<br />
standardized, controlled-rate cell<br />
freezing<br />
Intuitive design.<br />
Proprietary advanced thermal management technology.<br />
Page 3
Page 4
Current methods are inconsistent and<br />
non-reproducible<br />
mmm<br />
Cooling samples in ice or gel-filled cooling blocks introduces a<br />
variety of problems.<br />
Ice cooling<br />
• Variable sample temp<br />
• Contamination<br />
• Wet, illegible labels<br />
• Non-reproducible method<br />
Gel-filled coolers<br />
• Highly variable sample temp<br />
(edge effect)<br />
• Short cooling duration<br />
• Cannot use while re-charging<br />
Page 5
CoolProducts provide consistent and<br />
reproducible sample cooling and freezing<br />
Using a thermo-conductive CoolRack ® module as an interface<br />
between the ice and sample provides a consistent and reproducible<br />
cooling method.<br />
Eliminating ice with a CoolBox system further minimizes the risk<br />
of sample contamination and provides hours of consistent and<br />
reproducible ice-free cooling or freezing.<br />
Page 6
CoolRack modules ensure reproducible<br />
cooling and thawing profiles<br />
Performance test: A temperature probe was placed into a 2.0 mL cryogenic vial containing 1.0 mL of water. The tube was<br />
inserted into a CoolRack CF45 thermo-conductive module. The module was placed onto a ThermalTray platform in a 37°C water<br />
bath and allowed to equilibrate. The CoolRack CF45 module was then removed and placed onto dry ice and equilibrated to -78°C<br />
(0 - 15 minutes) and then returned to the water bath to re-equilibrate to 37°C (15 - 30 minutes). This experiment was repeated five<br />
consecutive times and temperature profiles were recorded.<br />
Conclusion: The CoolRack CF45 module showed identical cooling profiles and phase transition (orange circles) over five<br />
consecutive freeze-thaw cycles.<br />
Page 7
CoolRack, CoolSink, ThermalTray:<br />
Compatible with broad temperature range<br />
-150˚C -78˚C 0˚ to 4˚C 37˚C +<br />
Liquid Nitrogen Dry Ice Ice Water Bath<br />
• Adapts from ambient (25 o C)<br />
to approx. -150 o C in 12-14<br />
minutes<br />
• Samples are upright and<br />
organized as they flash freeze<br />
• No direct contact between<br />
sample and LN 2<br />
• Reproducible method<br />
• Adapts from ambient (25 o C)<br />
to -78 o C in 5-7 minutes<br />
• No need for ethanol – cost<br />
savings, no hazardous waste,<br />
no “sunk” tubes<br />
• Samples are upright and<br />
organized as they snap-freeze<br />
• Same freezing rate as direct<br />
immersion into dry ice or<br />
alcohol slurry<br />
• Reproducible method<br />
• Adapts from ambient (25 ç C)<br />
to 100°C).<br />
Samples protected from direct contact with temperature source.<br />
Page 8
CoolRack, CoolSink, ThermalTray:<br />
Accommodates variety of tubes and plates<br />
CoolRack ® tube modules<br />
• Including SBS-format modules<br />
CoolSink ® plate modules*<br />
• Including SBS-format modules<br />
ThermalTray platforms*<br />
• For supporting CoolRack and CoolSink<br />
modules in liquid<br />
* Patented<br />
Page 9
CoolBox: Ice-free workstations<br />
CoolBox XT & 2XT CoolBox MP CoolBox 30 XT Starter<br />
Holds Tubes <br />
Holds Plates <br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Page 10
CoolBox: How it works<br />
CoolBox XT and 2XT CoolBox MP and 30<br />
Lid<br />
CoolRack or CoolSink<br />
sample module<br />
Cooling Cartridge<br />
(Pre-frozen in -20˚C<br />
freezer)<br />
Base<br />
Simply pre-freeze the Cooling Core or cartridge in a -20°C freezer, place it in the base<br />
of the CoolBox, and rest a CoolRack or CoolSink module on top.<br />
Page 11
CoolBox and CoolRack: Accessories<br />
TruCool ® ice pans and buckets<br />
• Made of non-toxic EVA foam<br />
• Non-skid bottom, insulative and non-sweating<br />
• 5 sizes, 7 colors<br />
TruCool ® microfuge tubes and cryogenic vials<br />
CryoCeps cryovial grippers<br />
• Microfuge tubes feature patented “pull back” cap ensures<br />
thumb never passes over open top minimizing<br />
contamination risk<br />
• Cryogenic vials feature unique thermally-fused gasket<br />
(replaces O-ring) and bar-codes for secure identification<br />
• CryoCeps grippers protect fingers from handling frozen<br />
vials and tubes<br />
CoolProbe temperature monitors<br />
• Monitor sample temperature while using CoolRack and<br />
CoolSink modules in ice<br />
• Fitted probes for CoolRack M, CoolRack CF(T)<br />
• Universal probe for other CoolRack and CoolSink modules<br />
Page 12
CoolBox and CoolRack:<br />
Use for a variety of applications<br />
If you currently use an ice bucket, gel-filled coolers,<br />
refrigerators, freezers, or water bath, CoolBox and CoolRack<br />
products will improve your processes. Ideal for:<br />
• Tissue / Cell culture<br />
• Tissue dissections & snap-freezing<br />
• Cell culture preparation and thawing<br />
• Protein / Proteomics<br />
• Protein isolation, sonication, fractionation<br />
• Trypsin digestion<br />
• Molecular biology<br />
• PCR preparations<br />
• RNA isolation<br />
• Reagent cooling<br />
• Microbiology<br />
• Bacteria and virus freezing<br />
Visit www.biocision.com/application-summary<br />
for application assistance.<br />
Page 13
Page 14
CoolCell ® : Alcohol-free cell freezing<br />
CoolCell<br />
CoolCell SV2<br />
CoolCell FTS30<br />
CoolCell 5ml LX<br />
CoolCell LX<br />
For a variety of tubes and capacities.<br />
The new standard for passive cell cryopreservation.<br />
Page 15
CoolCell: How it works<br />
Passive controlled-rate cell freezing container<br />
• Replaces alcohol-based containers such as “Mr. Frosty”<br />
• Simply fill with vials and place -80 o C freezer<br />
• Radially-symmetric thermal exchange design ensures<br />
uniform cooling profiles to all vial positions<br />
• Composed of high-density materials used in aerospace<br />
industry for lightweight & insulative properties<br />
• Highly thermo-conductive alloy core<br />
• Models include conduction and/or micro-convection air<br />
flow control<br />
• Equal or better results than programmable step-down<br />
freezers and alcohol-based freezing containers<br />
Patent Pending<br />
Replaces “Mr. Frosty” and programmable freezers.<br />
No alcohol. No on-going maintenance or cost. No hazardous waste disposal.<br />
“Mr. Frosty” is a trademark of Thermo Fisher Scientific.<br />
Page 16
CoolCell containers ensure reproducible<br />
freezing profiles<br />
Five consecutive freezing runs show extremely consistent thermal profiles.<br />
Page 17
CoolCell vs. “Mr. Frosty”<br />
CoolCell Isopropanol Container<br />
Consistent freezing rate<br />
• All vials have uniform freezing profiles <br />
No isopropanol<br />
• No maintenance<br />
• No pre-cooling <br />
• No hazardous waste <br />
No hidden cost <br />
• Once you buy it, you’re done paying for it!! <br />
Easy to use <br />
• Cap removes easily when frozen <br />
• Not cold to the touch when frozen, no gloves<br />
needed <br />
• Ready for reuse after 5 minute warm-up time <br />
Minimal impact on freezer <br />
• 1/3 the heat impact on freezer; nearby samples<br />
remain unharmed <br />
Inconsistent freezing rate<br />
• Isopropanol degradation ensures variability<br />
• Two circles of vials results in further non-uniform<br />
heat removal <br />
Requires Isopropanol <br />
• Track uses so can replenish IPA every 5 th use<br />
• On-going maintenance<br />
• Spill risk<br />
• Pre-cool in refrigerator (safety issue)<br />
> $350 per unit per year to maintain properly <br />
• Isopropanol expense <br />
• Hazardous waste disposal costs <br />
Difficult to handle<br />
• Cap is difficult to open when frozen, unit is slippery<br />
(cells are warming up) <br />
• Protective glove required when handling frozen unit <br />
• Unit is cold, slippery, breakable <br />
Impacts local freezer area <br />
• Large heat capacity removed from alcohol impacts<br />
nearby samples <br />
Page 18
CoolCell: Compatible with many cell types<br />
Cell Lines<br />
• LnCap, HTB77, A549, others<br />
• Data and testing done by Lonza (Germany)<br />
Primary Cells<br />
• Variety of primary cells tested by labs at UCSF and ZenBio<br />
Stem Cells and Cell Therapy Products<br />
• Testing and data performed by USCF (Bluestone lab), TxCell and others<br />
See CoolCell data at:<br />
http://www.biocision.com/resources/coolcell-performance-data<br />
Viability and post-thaw functionality<br />
as good or better than “Mr. Frosty” and programmable freezers.<br />
Page 19
Cell Cryopreservation: Accessories<br />
XT Starter ice-free cooling platform<br />
• Ideal for use in the hood w<strong>here</strong> ice is forbidden<br />
• XT Starter and CoolRack modules provide compact, icefree<br />
cooling for cryogenic and cell therapy vials<br />
TruCool ® Hinged CryoBoxes<br />
• Patented hinged lid ensures lid is always put on<br />
correctly, keeping markings in synch with cryovials<br />
• Boxes for 1ml & 2ml vials, and for taller vials<br />
• 6 bright colors<br />
• With or without LN 2 drain holes<br />
TruCool ® cryogenic vials<br />
CryoCeps cryogenic vial grippers<br />
• Patented fused gasket layer on vial closure ensures<br />
leak-proof seal<br />
• Bar-coded vials for secure sample identification<br />
• CryoCeps* protect fingers when handling frozen vials<br />
* Patent pending<br />
Page 20
Thank you!<br />
For questions, contact us at: info@biocision.com<br />
© 2014. <strong>BioCision</strong>, LLC. All rights reserved. <strong>BioCision</strong>, Standardizing Samples, CoolRack, CoolSink, ThermalTray,<br />
CoolBox, CoolCell, TruCool, CoolProbe, CryoCeps are designated trademarks owned by <strong>BioCision</strong>, LLC..