Catalog No.589<br />

<strong>Data</strong> <strong>Recorder</strong> <strong>Interface</strong><br />

<strong>Data</strong> Transfer and <strong>Data</strong> Display Software<br />

for SIR-1000 Series of High-Speed<br />

Digital <strong>Data</strong> <strong>Recorder</strong>s<br />

<br />

For Windows ® 95 / Windows NT ®<br />

PCscan III is a software program transferring measurement data<br />

recorded by SIR-1000 series of high speed digital data recorder<br />

to a personal computer. Search for interested data on a tape<br />

could be easier and faster with PCscan III ’s simple operation.<br />

PCscan III enables analog data to be checked in a form of<br />

waveforms or numerical values on monitor display. PCscan III<br />

can export the data in many well-used file formats for analysis.<br />

Besides, PCscan III is also capable of simultaneous replaying<br />

MPEG video and analog data, which significantly enhances the<br />

efficiency of measurement and analysis.<br />

(Video replay is supported in MPEG 1 only, although data<br />

transferring of both MPEG 1 and 2 is supported.)<br />

High Speed Digital <strong>Data</strong> <strong>Recorder</strong>, SIR-1000 Series<br />

This series is a high-speed digital data recorder based on<br />

the Advanced Intelligent Tape (AIT), which is the most<br />

advanced magnetic recording technology up to now. It<br />

offers non-stop recording as long as 2 hours for a<br />

bandwidth as wide as 20kHz up to 16 channels for the<br />

standard and it could be expanded to as many as 128<br />

channels/recorder. SIR-1000W enables 160kHz recording<br />

in the use of four channel mode, SIR-1000 and 1000i<br />

enables 20kHz recording in the use of 16 channel mode.<br />

Digital data output through SCSI interface is available in<br />

addition to analog output. It achieves easy data transfer to a<br />

personal computer at high speed.


PCscan III provides a data recording system using the SIR-1000 series of<br />

high-speed digital data recorders. This series includes among its many<br />

features a high-performance A/D converter, data recording in a wide<br />

bandwidth of 20 kHz (or, with the SIR-1000W, up to 160 kHz), expandability<br />

from 16 up to 128 channels (or, with the SIR-1000W, up to 4 channels for<br />

160 kHz and up to 16 channels for 40 kHz), digital data input options to<br />

meet users’ requirements, data storage with a large capacity up to 25GB,<br />

and a data search capability at high speeds up to 75 times normal speed.<br />

With PCscan III, all these functions can easily and comfortably be<br />

controlled using mouse operations in Windows ® 95 or WindowsNT ® .<br />

<strong>Data</strong> Transfer<br />

High-accuracy data recorded by the SIR-1000 series can be directly<br />

transferred to the computer’s hard disk under the filenames of the user’s<br />

choice. The entire contents of a tape can be viewed at a glance and the<br />

desired data can be accessed quickly using the TOC (table of contents)<br />

information recorded on the tape.<br />

•Transfer triggers<br />

IDs, addresses, time codes (Real Time Pack), current positions<br />

• Transfer size settings<br />

Channel selection, decimation, auto numbering<br />

• TOC information display<br />

Display of TOC information (IDs, B/C modes, tape speeds, recording<br />

durations, etc.) recorded on the tape, enabling quick selection of the<br />

target data<br />

• Real-time data filing<br />

<strong>Data</strong> can be transferred to the computer in real-time as the<br />

measurements are being performed, and filed.<br />

<strong>Data</strong> Transfer Window<br />

TOC (Table of Contents)<br />

All the TOC information for the data recorded on a tape is recorded on<br />

the tape and in the memory (MIC: Memory in Cartridge) installed in the<br />

cartridge. Recorded in TOC is such information as the IDs, B/C modes,<br />

tape speeds and recording durations, and the recorded contents can be<br />

checked at a glance. Using this information, target data blocks can easily<br />

be selected and transferred from the screen.<br />

• TOC information<br />

IDs, start IDs, data types (analog/digital/full/mixed), B/C modes, tape<br />

speeds, recording lengths, recording dates, recording times<br />

TOC Window


By means of 32-bit mode programming, PCscan III affords quick access to<br />

the very data required for actual analysis from among the huge volumes of<br />

data contained on a tape. Simply by clicking or dragging the mouse,<br />

whatever data is needed can be enlarged or reduced by zooming in or out<br />

and filed away in the optimum format. Analysis can be performed for<br />

specifically selected ranges of data, the data can be monitored as waveforms,<br />

numerical values, sound or images, and only those channels needed can be<br />

converted into the format of the user’s choice, and exported.<br />

Work Bench Window<br />

<strong>Data</strong> Viewer<br />

On the Work Bench Window, the transferred data can be monitored in<br />

greater detail, and the data needed can be selected and filed under the<br />

format of the user’s choice. Simply by clicking or dragging the mouse,<br />

waveforms can be enlarged by zooming in, channels can be selected at<br />

will, and the kind of operating ease available only from Windows ® 95 or<br />

WindowsNT ® can be assured. Furthermore, using a sound board, selected<br />

data can be reproduced as sounds which is very helpful for monitoring<br />

noise or acoustic data.<br />

<strong>Data</strong> Conversion<br />

•Display selection<br />

Number of channels, Zoom in/out, Channel labeling, Engineering unit<br />

conversion<br />

•<strong>Data</strong> monitoring<br />

Maximum values, Minimum values, P-P values, Average values,<br />

RMS values, Times, Frequencies, List data, Sounds<br />

•<strong>Data</strong> output settings<br />

Channels, Decimation, File formatting<br />

•<strong>Data</strong> analysis results display<br />

Analysis of data in the range selected by the mouse and display of<br />

analysis results; Choice of analysis functions including power spectrum,<br />

1/3 octave, Histogram, X-Y graph plotting, Primary differentiation, and<br />

Secondary differentiation and integration; Analysis results printed out or<br />

saved as files.<br />

•Real-time analog data monitoring<br />

The prevailing measurement conditions can be displayed as waveforms<br />

in real time. (Real Time Pack)<br />

<strong>Data</strong> in a specific range can be selected by clicking and dragging the<br />

mouse on the Work Bench Window and converted into a dedicated file<br />

format for direct analysis using a wide range of analysis software. This<br />

enables the high-accuracy measurement data recorded by the SIR-1000<br />

series to be analyzed with no accompanying deterioration, leading to<br />

high-quality analysis results.<br />

• Formats supported<br />

Binary (Intel86), Binary (Motorola68), ASCII-Eng (delim/comma),<br />

ASCII-Eng (delim/tab), ASCII-Eng (delim/space), WAVE, DADiSP,<br />

MATLAB, SnapMaster (HEM), STAR, nVision (EZFile) UDF58 (I-<br />

DEAS/ASCII)<br />

<strong>Data</strong> Conversion Window


Computer <strong>Interface</strong><br />

PCscan III supports the Wide SCSI-2 interface.<br />

• Streamer Pack: This is used for real-time data transfer using an STB-10<br />

board and SDX drive. It is also used for data display functions. When used in<br />

conjunction with an SDX emulation board (STB-10) and SDX streamer drive,<br />

additional functions are provided: already recorded data can be transferred and<br />

displayed, and data can be converted for major analysis software programs.<br />

• Real Time Pack: This is used for real-time data transfer using the STB-30<br />

board. When used in conjunction with a high-speed SCSI transfer board (STB-<br />

30), a recorder in the SIR-1000 series can be used as a compact, highperformance<br />

front end, enabling waveform display and data transfer to be<br />

accomplished.<br />

SIR-1000 series<br />

SDX streamer drive<br />

Wide SCSI-2<br />

IBM-PC ® /AT<br />

Computer Environment Requirements<br />

• Streamer Pack (for using STB-10, SDX drive or for data display functions)<br />

Computer : IBM-PC/AT or compatible with Pentium ® 120 MHz or faster<br />

(Pentium ® II 266 MHz or faster recommended)<br />

Memory : 64 MBytes or more (128 MBytes or more recommended)<br />

Video card : 800 × 600 pixels or more (256 colors or more recommended)<br />

(When using the video playback functions)<br />

Computer : Pentium ® II 350 MHz or faster (Pentium ® III 650 MHz or faster<br />

recommended)<br />

Memory : 128 MBytes or more (256 MBytes or more recommended)<br />

Video card : 1024 × 768 pixels or more (65536 colors or more<br />

recommended)<br />

• Real Time Pack (for using STB-30)<br />

Computer : IBM-PC/AT or compatible with Pentium ® II 266 MHz or faster<br />

(Pentium ® II 350 MHz or faster recommended)<br />

Memory : 128 MBytes or more (256 MBytes or more recommended)<br />

Video card : 800 × 600 pixels or more (256 colors or more recommended)<br />

• Common requirements<br />

Operating system : Windows ® 95 or WindowsNT ® 4.0<br />

<strong>Interface</strong> : PCI bus slot × 1<br />

SCSI host adapter: Adaptec’s AHA-2940UW, AHA-2940U2W or ASC-29160<br />

Cable<br />

: Adaptec’s ACK/WP, WP<br />

Disk drive : 3.5-inch type (2HD/1.44MB)<br />

Display : Display supporting Windows ® 95 or WindowsNT ® , 15” type or<br />

larger recommended<br />

Mouse : Mouse supporting Windows ® 95 or WindowsNT ®<br />

System Configuration<br />

•<strong>Data</strong> transfer from the SIR-1000 Series to a PC<br />

SDX emulation board STB-10, PCscan software: SUK-330<br />

Recorded data<br />

SIR-1000 series<br />

<br />

<br />

Wide-SCSI cable<br />

SDX emulation board (STB-10)<br />

(Mounted in the option slot on the rear panel of the data recorder)<br />

IBM-PC ® or compatible machine<br />

PC scan<br />

software<br />

SCSI host adapter<br />

ADAPTEC<br />

ASC-29160<br />

PCI bus connection<br />

•AD converted incoming signals from the SIR-1000 Series to a PC in real time. The SIR-1000 Series as a high performance front end<br />

High-speed SCSI transfer board: STB-30, PCscan software: SUK-330<br />

IBM-PC ® or compatible machine<br />

Input signals<br />

•Recorded data from an AIT streamer drive to a PC<br />

SDX streamer drive (Stand-alone type), PCscan software: SUK-330<br />

SIR-1000 series<br />

<br />

<br />

Wide-SCSI cable<br />

High-speed SCSI transfer board (STB-30)<br />

(Mounted in the option slot on the rear panel of the data recorder)<br />

PC scan<br />

software<br />

SCSI host adapter<br />

ADAPTEC<br />

ASC-29160<br />

PCI bus connection<br />

IBM-PC ® or compatible machine<br />

Recorded data<br />

<br />

<br />

Wide-SCSI cable<br />

SCSI host adapter<br />

PC scan<br />

software<br />

SDX streamer drive (Built-in type/Stand-alone type)<br />

ADAPTEC<br />

ASC-29160<br />

PCI bus connection<br />

•Company names and product names appearing herein are trademarks or registered trademarks of the companies concerned.<br />

•Ratings, specifications and design are subject to change without notice.<br />

Sony Precision Technology Inc.<br />

Toyo Building, 9-17, Nishigotanda 3-chome, Shinagawa-ku, Tokyo,<br />

141-0031 Japan<br />

Phone: +81+3-3490-9481 Fax: +81+3-3490-8028<br />

http//www.sonypt.co.jp/<br />

Description of this brochure is based on the specifications as of August 200<br />

Distributed by:<br />

© <br />

Printed on recycled paper

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!