BLR<br />

Audit<br />

<strong>Checklist</strong>s<br />

<strong>Portable</strong> <strong>Fire</strong><br />

<strong>Extinguisher</strong>s<br />

<strong>Portable</strong> <strong>Fire</strong> <strong>Extinguisher</strong> <strong>Checklist</strong><br />

<strong>Checklist</strong><br />

YES<br />

NO<br />

Selection and Distribution<br />

◆<br />

◆<br />

◆<br />

◆<br />

Are extinguishers selected and distributed based<br />

on the classes and degrees of fire hazards that exist in<br />

different work areas in your facility<br />

Are extinguishers clearly identified with unobstructed<br />

signs visible from a distance<br />

Are extinguishers easily accessible to employees who<br />

may need to use them<br />

—Are they mounted at a reasonable height<br />

—Are they located within the appropriate travel distance<br />

outlined in the regulations<br />

—Can they be reached and removed without the use<br />

a ladder or special equipment<br />

Does your selection and distribution of extinguishers meet the<br />

requirements of your insurance carrier and your local fire codes<br />

Employee Training<br />

◆<br />

◆<br />

◆<br />

◆<br />

◆<br />

10007700<br />

© Business & Legal Reports, Inc.<br />

Have all employees who you want to use extinguishers in the<br />

event of a fire been trained to use them effectively<br />

Do employees understand the basic principles of different classes<br />

of fires and the hazards associated with using fire extinguishers<br />

Do employees know when it is safe to attempt to contain a fire<br />

with an extinguisher and when it is safer to evacuate<br />

Are employees trained in the use of fire extinguishers when first<br />

hired and at least annually thereafter<br />

Are any employees who have been specially designated as emergency<br />

responders under your emergency action plan been given<br />

special training in handling fire-fighting equipment, including fire<br />

extinguishers<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

Continued ☞<br />

140-7


☞<br />

BLR<br />

Audit<br />

<strong>Checklist</strong>s<br />

<strong>Portable</strong> <strong>Fire</strong><br />

<strong>Extinguisher</strong>s<br />

<strong>Checklist</strong><br />

Continued<br />

YES<br />

NO<br />

◆<br />

Do these specially designated employees receive training when<br />

they are first assigned to fire-fighting duties and at least annually<br />

thereafter<br />

❏ ❏<br />

Inspection and Maintenance<br />

◆<br />

◆<br />

Are all extinguishers inspected visually once a month to make<br />

sure that they are in good condition<br />

Do employees who conduct extinguisher inspections date and initial<br />

the tag on the extinguisher<br />

❏ ❏<br />

❏ ❏<br />

◆<br />

◆<br />

◆<br />

◆<br />

◆<br />

◆<br />

◆<br />

Does each visual inspection include a check of the following<br />

items:<br />

—Pressure gauge<br />

—Hose and housing (for possible leaks or obstructions)<br />

—Pin (intact)<br />

Are extinguishers immediately removed from service when any<br />

problem is discovered<br />

Are all extinguishers given a maintenance check annually<br />

Is the maintenance check performed by a trained person with<br />

suitable equipment and facilities<br />

Whenever an extinguisher is removed from service, is another<br />

serviceable extinguisher (or alternate equivalent form of protection)<br />

put in its place<br />

If inspections or routine maintenance turns up problems with an<br />

extinguisher, are repairs made promptly or is the extinguisher<br />

replaced<br />

Are complete records kept of all maintenance and repairs to<br />

extinguishers<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

Testing Requirements<br />

◆<br />

Are extinguishers hydrostatically tested according to the<br />

timetable contained in the OSHA regulations<br />

❏ ❏<br />

140-8<br />

Continued ☞<br />

10007700<br />

© Business & Legal Reports, Inc.


BLR<br />

Audit<br />

<strong>Checklist</strong>s<br />

<strong>Portable</strong> <strong>Fire</strong><br />

<strong>Extinguisher</strong>s<br />

<strong>Checklist</strong><br />

YES<br />

NO<br />

◆<br />

◆<br />

◆<br />

Are defective extinguishers replaced immediately<br />

Are complete records of testing kept in your files<br />

—Date of testing<br />

—Signature of person conducting test<br />

—Serial number (or other identifier) of extinguisher<br />

Are extinguishers hydrostatically tested (in addition to routine<br />

tests) whenever they show evidence of corrosion or mechanical<br />

injury<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

❏ ❏<br />

10007700<br />