30.01.2015 Views

Addendum 'B' - Oregon University System

Addendum 'B' - Oregon University System

Addendum 'B' - Oregon University System

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Addendum</strong> ‘B’<br />

Project: <strong>University</strong> of <strong>Oregon</strong> Straub Hall Deferred<br />

Maintenance and Seismic Upgrade<br />

Date: 05/24/2013<br />

To: Bidding Contractors<br />

From: Rowell Brokaw Architects<br />

1.1 GENERAL ITEMS<br />

A. The existing basement slab was core drilled to assess its construction. Based on the core<br />

drill and original construction documents, it should be assumed that the existing<br />

basement slab structure is (2) 3” slabs with a layer of cork waterproofing between.<br />

B. Mechanical, Electrical and Plumbing substitution requests with Engineer review attached.<br />

C. Straub Hall Window Condition Assessment, prepared by the <strong>University</strong> of <strong>Oregon</strong> and<br />

dated May 2011, is attached.<br />

1.2 CHANGES TO DRAWINGS<br />

A. SheetG1.01:<br />

1. Attic Demolition Plan added. Drawing #4.<br />

B. Sheet A2.00:<br />

1. Keynotes at three sump pumps revised.<br />

2. Detail A revised.<br />

3. Door to room V031 changed to cased opening.<br />

C. Sheet A2.01:<br />

1. Gates at stairs S130 and S170 revised to doors.<br />

D. Sheet A2.10:<br />

1. Door 031-2 to room V031 changed to cased opening.<br />

E. Sheet A2.11:<br />

1. Gates 130-4 and 170-2 at stairs S130 and S170 revised to doors.<br />

F. Sheets A2.02, A2.03, A2.04, A2.12, A2.13, A2.14:<br />

1. Keynote A 099 revised to read: “FIX (E) FIRE ESCAPE DOOR IN<br />

PLACE. REMOVE (E) DOOR HARDWARE PER HARDWARE<br />

SCHEDULE.”<br />

G. Sheet A2.20:<br />

1. Lighting quantities revised to match Electric.<br />

H. Sheet A2.21:<br />

1. Lighting quantities revised to match Electric.<br />

2. Chilled beam quantities revised to match Mechanical.<br />

3. Typical Ceiling Layout Key revised.<br />

I. Sheet A2.22:<br />

1. Lighting quantities revised to match Electric.<br />

2. Chilled beam quantities revised to match Mechanical.<br />

3. Removed soffit and revised ceiling in room 299.<br />

4. Typical Ceiling Layout Key revised.<br />

J. Sheet A2.23:<br />

1. Lighting quantities revised to match Electric.<br />

2. Chilled beam quantities revised to match Mechanical.<br />

3. Typical Ceiling Layout Key revised.


K. Sheet A2.24:<br />

1. Lighting layout revised.<br />

2. Typical Ceiling Layout Key revised.<br />

L. Sheet A3.01:<br />

1. Revised to add WINDOW REFURBISHMENT notes.<br />

M. Sheet A3.02:<br />

1. Revised to add WINDOW REFURBISHMENT notes.<br />

2. Keynote A 099 revised to read: “FIX (E) FIRE ESCAPE DOOR IN<br />

PLACE. REMOVE (E) DOOR HARDWARE PER HARDWARE<br />

SCHEDULE.”<br />

3. Revised to add additional detail callouts at elevations 6 and 7.<br />

N. Sheet A4.02:<br />

1. Section #5 revised to reflect change to 1st and 2nd floor WC's from <strong>Addendum</strong> A.<br />

O. Sheet A5.01:<br />

1. Drawings 13 and 14 revised to show door in place of gate on hold open at first<br />

floor stair landings.<br />

P. Sheet A7.05:<br />

1. Detail #3 deleted.<br />

Q. Sheet A7.10:<br />

1. Drawings 4 and 8 revised to remove gate on hold open.<br />

R. Sheet A7.20:<br />

1. Detail 2 revised.<br />

2. Detail 14 added<br />

S. Sheet A8-01:<br />

1. Door Hardware Schedules revised.<br />

2. Door 031-2 revised to cased opening.<br />

3. Doors 130-4 and 170-2 revised from gates to aluminum storefront.<br />

T. Sheet A8-02:<br />

1. Door Hardware Schedules revised.<br />

1.3 CHANGES TO SPECIFICATIONS<br />

A. Section 06 6100 Architectural Fiberglass: Add new specification attached to volume 1 of<br />

specifications<br />

B. Section 08 1116 Aluminum Doors and Frames: Add new specification attached to volume<br />

1 of specifications.<br />

C. Section 08 7100 Door Hardware:<br />

1. Append Door Hardware Schedule and Door Hardware Index attached to end of<br />

section<br />

D. Section 09 2116 Gypsum Board Assemblies:<br />

1. Delete paragraph 2.05-G<br />

2. Delete paragraph 3.09<br />

E. Section 09 5100 Acoustical Ceilings:<br />

1. Add paragraph 2.01-A-3 to read:<br />

“3. Certainteed: www.certainteed.com”<br />

2. Revise paragraph 2.01-C-7 to read:<br />

“7. Product:<br />

a. Ultima Tegular, Fine Texture, Model 1911 by Armstrong<br />

b. Performa 1222BB-IOF-1 by Certainteed”<br />

End of <strong>Addendum</strong> B<br />

Straub DM <strong>Addendum</strong> B 2 / 2


To:<br />

Attn:<br />

Submittal<br />

Rowell Brokaw Architects<br />

1 East Broadway, Suit 300<br />

Eugene, OR Date: May 06, 2013<br />

Project: (UO) STRAUB HALL - DEFERR<br />

ED MAINT<br />

Original Submittal for Prior Approval<br />

1 Copy of Submittals is Attached<br />

TYPE MFG DESCRIPTION<br />

A<br />

Metalumen RM4DI-2-T8-4-OL-OL-W-E-1-277-N<br />

Mfg.<br />

B<br />

Metalumen RM4D-2-T8-4-N-OL-S-E-1-277-N<br />

Mfg.<br />

B1<br />

Metalumen RM4D-2-T8-4-N-OL-Y-E-1-277-N<br />

Mfg.<br />

D Omega OM4LED28277-R4LED40KHZ<br />

D1 Omega OM4LED28277-R4LED40KWWHZ<br />

G<br />

Linear<br />

Lightin<br />

WW6-D-1-ET5-SBL-G-NO-4<br />

Offering T5 Lamping<br />

H<br />

Metalumen RM4D-1L-LED40K-2-OL-(RT OR RD)-X-D350-1-277-N<br />

Mfg.<br />

H1<br />

Metalumen RM4D-1L-LED40K-4-OL-(RT OR RD)-X-D350-1-277-N<br />

Mfg.<br />

H2<br />

Metalumen RM4D-1L-LED40K-4-OL-(RT OR RD)-X-D700-1-277-N<br />

Mfg.<br />

H3<br />

Metalumen RM4D-1L-LED40K-2-OL-(RT OR RD)-X-D700-1-277-N<br />

Mfg.<br />

M<br />

Metalumen RM4D-2-T8-4-N-OL-W-X-E-1-277-N<br />

Mfg.<br />

P<br />

Metalumen RM4DI-2-T8-4-OL-OL-Y-E-1-277-N<br />

Mfg.<br />

SA Omega OM4LED28277-R4LED40KHZ<br />

SA1 Omega OM6LEDXX277DL-R6LED40KHZDL<br />

SB Gardco 941L-20LA-C-DG-NW-UNVI-BRP<br />

V1<br />

Metalumen<br />

Mfg.<br />

RM4D-2-T8-4-OL-S-X-E-1-277-N<br />

Crestron Controls<br />

Remarks:<br />

Page 1


Submittal<br />

To: Rowell Brokaw Architects<br />

1 East Broadway, Suit 300<br />

Eugene, OR Date: May 06, 2013<br />

Project: (UO) STRAUB HALL - DEFERR<br />

Attn:<br />

ED MAINT<br />

TYPE MFG DESCRIPTION<br />

Philips Dynalite Controls<br />

Page 2


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Arch Ltg Works, Up and Under Series<br />

Section 26500 Type: A<br />

PROPOSED SUBSTITUTION: Metalumen, RM4DI-2-T8-4-OL-OL-W-E-1-277-N<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

By Jesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Please provide sample of the<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />

Grande family<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


TYPE A<br />

Ordering Guide<br />

Grande RM4DI<br />

Series<br />

T8, T5, T5H0 DIRECT/IDIRECT – Pendant, Wall<br />

TAB<br />

15<br />

106 [4.2]<br />

135 [5.3]<br />

135 [5.3]<br />

91 [3.6]<br />

91 [3.6]<br />

95 [3.7]<br />

95 [3.7]<br />

Pendant<br />

Wall<br />

Part number example<br />

RM4DI 3 T8 4 N SL Y A E 1 120 N<br />

Model<br />

RM4DI<br />

Number of<br />

Lamps<br />

Lamp<br />

Type<br />

Length<br />

Control<br />

Up<br />

Control<br />

Down<br />

Mounting<br />

Finish<br />

Ballast<br />

Driver<br />

Circuitry Voltage Options<br />

No. of Lamps Length Control Up<br />

2<br />

1 Up/1 Down<br />

2S<br />

1 Up/1 Down<br />

Staggered*<br />

2L<br />

1 Up/1 Down<br />

3<br />

1 Up/2 Down*<br />

3S<br />

1 Up/2 Down<br />

Staggered*<br />

4<br />

2 Up/2 Down*<br />

4S<br />

2 Up/2 Down<br />

Staggered*<br />

*(T8 with opal<br />

satin lens only)<br />

Lamp Type<br />

4<br />

4 Foot<br />

8<br />

8 Foot<br />

12<br />

12 Foot<br />

R<br />

Continuous<br />

Length<br />

(consult<br />

factory)<br />

(fixtures<br />

supplied in<br />

nominal 1’<br />

increments only)<br />

T8 32W<br />

T5 28W<br />

T5HO 54W<br />

LED30K* 3000k<br />

LED35K* 3500k<br />

LED40K* 4000k<br />

*available with opal satin lens only<br />

N<br />

None<br />

OL<br />

Opal<br />

Satin<br />

Lens<br />

Control<br />

Down<br />

SL<br />

Specular<br />

Parabolic<br />

Louver<br />

SSL<br />

Semi<br />

Specular<br />

Parabolic<br />

Louver<br />

OL<br />

Opal Satin<br />

Lens<br />

A<br />

Asymmetrical<br />

reflector<br />

(single T5,<br />

T5HO, T8 only)<br />

Mounting Ballast Circuitry Voltage Options<br />

Pendant<br />

Y<br />

Yoke<br />

Aircraft<br />

Cable<br />

W<br />

Wall<br />

Finish<br />

A Anodized<br />

Aluminum<br />

C Custom<br />

For custom<br />

Finish specify<br />

RAL#<br />

Standard<br />

E<br />

Electronic Instant Start T8<br />

Programmed Rapid Start -T5/T5HO<br />

Dimming 120V/277V Dimming<br />

D1 Advance Mark 7<br />

(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />

D2 Advance Mark 10<br />

(1/2 Lamp T8, 1/2 Lamp T5HO)<br />

D4 Lutron Hi-lume<br />

(1/2 Lamp T8, T5HO)<br />

D5 Lutron Eco-<strong>System</strong><br />

(T5-T5HO-T8) (347V available)<br />

(some lamp/ballast cominations may not be<br />

available — consult factory for availability)<br />

Battery Pack Options<br />

BN1 Bodine B50LP (T8)<br />

BN2 Bodine LP400 (T8)<br />

BN3 Bodine LP500 (T5)<br />

BN4 Bodine LP600 (T5/T5HO/T8)<br />

1<br />

1 Circuit<br />

(Standard)<br />

AB*<br />

Alternating<br />

Switching<br />

EN*<br />

Emergency/<br />

Night Light<br />

LED Driver<br />

/LR*<br />

Left-right<br />

Switching<br />

*n/a for LED<br />

120<br />

277<br />

347*<br />

*(not<br />

available<br />

for LED)<br />

N<br />

None<br />

D<br />

Daylight<br />

Sensor<br />

O<br />

Occupancy<br />

Sensor<br />

DOS<br />

Daylight/<br />

Occupancy<br />

Sensor<br />

Maximum fixture lumens/foot<br />

Standard Dimming 3000k 3500k 4000k<br />

S350 (350mA) D350 (350mA) 959 1019 1065<br />

S700 (700mA) D700 (700mA) 1918 2038 2130<br />

Approvals<br />

R1-07-12<br />

570 Southgate Drive, Guelph, Ontario N1G 4P6<br />

Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />

T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />

www.metalumen.com<br />

(UO) Straub Hall - Deferred Maintenance<br />

Signature<br />

Type A<br />

Metalumen: RM4DI-2-T8-4-OL-OL-W-E-1-277-N<br />

Northern Date Illumination Company<br />

3


TYPE A<br />

Ordering Guide<br />

SPECIFICATIONS<br />

Grande RM4DI<br />

Series<br />

T8, T5, T5H0 DIRECT/IDIRECT – Pendant, Wall<br />

TAB<br />

15<br />

CONSTRUCTION SPECIFICATIONS<br />

T8, T5, T5HO<br />

LED<br />

HOUSING<br />

Rigid extruded aluminum body, 2.0mm [0.08”]<br />

nominal wall thickness. 95mm [3.7”] width x 135mm<br />

[5.3”] high<br />

End Caps: C.R.S.<br />

FINISH<br />

Anodized aluminum, Custom finishes available.<br />

LIGHTING CONTROL OPTIONS<br />

Specular or semi specular parabolic louvre<br />

High transmittance snap in satin lens<br />

Asymmetrical reflector — single lamp only — open<br />

bottom<br />

MOUNTING<br />

PENDANT<br />

Steel aircraft cable yoke complete with a Quick-Grip<br />

field adjustable suspension system provides for quick<br />

and easy onsite alignment.<br />

135 [5.3]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

135 [5.3]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

1<br />

WALL<br />

Wall brackets supplied<br />

106 [4.2]<br />

106 [4.2]<br />

LED/DRIVER SPECIFICATIONS<br />

Medium power LED’s<br />

Color temperatures available: 3000K, 3500K, 4000K<br />

CRI: 84 (4000k) (80 minimum)<br />

Nominal power consumption: 15W - 700mA, 7.5W -<br />

350mA<br />

Hours: 50,000<br />

Maximum delivered lumens/foot:<br />

350mA<br />

3000K 959 lm/ft<br />

3500K 1019 lm/ft<br />

4000K 1065 lm/ft<br />

700mA<br />

3000K 1918 lm/ft<br />

3500K 2038 lm/ft<br />

4000K 2130 lm/ft<br />

Voltage: 120V or 277V input voltage.<br />

Heat Sink: Extruded Aluminum Profile<br />

LED connections: Board mounted connectors.<br />

Drivers: available from several manufacturers.<br />

Drivers matched to run lengths and specific LED light<br />

engines.<br />

135 [5.3]<br />

Wall<br />

91 [3.6]<br />

95 [3.7]<br />

135 [5.3]<br />

Wall<br />

91 [3.6]<br />

95 [3.7]<br />

Certification<br />

Testing Standards: Tested in accordance with IESL-<br />

M79-08<br />

RoHS Compliant<br />

Warranty: 3 year<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type A<br />

Metalumen: RM4DI-2-T8-4-OL-OL-W-E-1-277-N<br />

Northern Illumination Company<br />

4<br />

R1-07-12


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Bartco, IPR8MS Series<br />

Section 26500 Type: B<br />

PROPOSED SUBSTITUTION: Metalumen, RM4D-2-T8-4-N-OL-S-E-1-277-N<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

Date: 5/7/13<br />

By Jesse Smith - Glumac Lighting Studio<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks Must have a wrap lens<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


TYPE B<br />

Ordering Guide<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

106 [4.2]<br />

102 [4.0]<br />

119 [4.7]<br />

119 [4.7]<br />

102 [4.0]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Part number example<br />

91 [3.6]<br />

115 [4.5]<br />

91 [3.6]<br />

120 [4.7]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant Recessed Drywall Recessed T-bar Surface Wall<br />

91 [3.6]<br />

95 [3.7]<br />

Dimensions and photometry see reverse.<br />

RM4D 2S T5 12 N SL RD A E 1 347 N<br />

Model<br />

RM4D<br />

Number of<br />

Lamps<br />

Lamp<br />

Type<br />

Length<br />

Control<br />

Up<br />

N<br />

Control<br />

Down<br />

Mounting<br />

Finish<br />

Ballast<br />

Driver<br />

Circuitry Voltage Options<br />

No. of Lamps Length Control Up<br />

1<br />

1 Lamp<br />

1S<br />

1<br />

Staggered*<br />

1L<br />

1 LED<br />

2<br />

2 Lamps*<br />

2S<br />

2<br />

Staggered*<br />

*(T8 with opal<br />

satin lens<br />

only)<br />

Lamp Type<br />

4<br />

4 Foot<br />

8<br />

8 Foot<br />

12<br />

12 Foot<br />

R<br />

Continuous<br />

Length<br />

(consult<br />

factory)<br />

(fixtures<br />

supplied in<br />

nominal 1’<br />

increments only)<br />

T8 32W<br />

T5 28W<br />

T5HO 54W<br />

LED30K* 3000k<br />

LED35K* 3500k<br />

LED40K* 4000k<br />

*available with opal satin lens only<br />

N<br />

None<br />

Control<br />

Down<br />

SL<br />

Specular<br />

Parabolic<br />

Louver<br />

SSL<br />

Semi<br />

Specular<br />

Parabolic<br />

Louver<br />

OL<br />

Opal Satin<br />

Lens<br />

A<br />

Asymmetrical<br />

reflector<br />

(single T5,<br />

T5HO, T8 only)<br />

Mounting Ballast Circuitry Voltage Options<br />

Pendant<br />

Y<br />

Yoke Aircraft<br />

Cable<br />

RT<br />

Recessed<br />

T-Bar<br />

RD<br />

Recessed<br />

Drywall<br />

S<br />

Surface<br />

W<br />

Wall<br />

Finish<br />

A<br />

Anodized<br />

Aluminum<br />

C<br />

Custom<br />

For custom<br />

Finish specify<br />

RAL#<br />

Standard<br />

E<br />

Electronic Instant Start T8<br />

Programmed Rapid Start -T5/T5HO<br />

Dimming 120V/277V Dimming<br />

D1 Advance Mark 7<br />

(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />

D2 Advance Mark 10<br />

(1/2 Lamp T8, 1/2 Lamp T5HO)<br />

D4 Lutron Hi-lume<br />

(1/2 Lamp T8, T5HO)<br />

D5 Lutron Eco-<strong>System</strong><br />

(T5-T5HO-T8) (347V available)<br />

(some lamp/ballast cominations may<br />

not be available — consult factory for<br />

availability)<br />

Battery Pack Options<br />

BN1 Bodine B50LP (T8)<br />

BN2 Bodine LP400 (T8)<br />

BN3 Bodine LP500 (T5)<br />

BN4 Bodine LP600 (T5/T5HO/T8)<br />

1<br />

1 Circuit<br />

(Standard)<br />

AB*<br />

Alternating<br />

Switching<br />

EN*<br />

Emergency/<br />

Night Light<br />

LED Driver<br />

/LR*<br />

Left-right<br />

Switching<br />

*n/a for LED<br />

120<br />

277<br />

347*<br />

*(not<br />

available<br />

for LED)<br />

N<br />

None<br />

D<br />

Daylight<br />

Sensor<br />

O<br />

Occupancy<br />

Sensor<br />

DOS<br />

Daylight/<br />

Occupancy<br />

Sensor<br />

Maximum fixture lumens/foot<br />

Standard Dimming 3000k 3500k 4000k<br />

S350 (350mA) D350 (350mA) 480 510 533<br />

S700 (700mA) D700 (700mA) 959 1019 1065<br />

Approvals<br />

R1-07-12<br />

570 Southgate Drive, Guelph, Ontario N1G 4P6<br />

Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />

T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />

www.metalumen.com<br />

(UO) Signature Straub Hall - Deferred Maintenance<br />

Type B<br />

Metalumen: RM4D-2-T8-4-N-OL-S-E-1-277-N<br />

Northern Date Illumination Company<br />

1


TYPE B<br />

Ordering Guide<br />

SPECIFICATIONS<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

CONSTRUCTION SPECIFICATIONS<br />

HOUSING<br />

Rigid extruded aluminum body, 2.0mm [0.08”]<br />

nominal wall thickness. 95mm [3.7”] width x 102mm<br />

[4.0”] high (Pendant/Wall/Surface)<br />

115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />

End Caps: C.R.S.<br />

FINISH<br />

Anodized aluminum, Custom finishes available.<br />

T8, T5, T5HO<br />

102 [4.0]<br />

LED<br />

102 [4.0]<br />

LIGHTING CONTROL OPTIONS<br />

Specular or semi specular parabolic louvre<br />

High transmittance snap in satin lens<br />

Asymmetrical reflector — single lamp only — open<br />

bottom<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

MOUNTING<br />

PENDANT<br />

Steel aircraft cable yoke complete with a Quick-Grip<br />

field adjustable suspension system provides for quick<br />

and easy onsite alignment.<br />

119 [4.7]<br />

119 [4.7]<br />

RECESSED<br />

T-Bar — Mounting clips supplied<br />

Drywall — Mounting brackets supplied<br />

WALL<br />

Wall brackets supplied<br />

SURFACE<br />

Direct to surface mount<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

LED/DRIVER SPECIFICATIONS<br />

Medium power LED’s<br />

Color temperatures available: 3000K, 3500K, 4000K<br />

CRI: 84 (4000K) (80 minimum)<br />

Nominal power consumption: 15W - 700mA, 7.5W -<br />

350mA<br />

Hours: 50,000<br />

Maximum delivered lumens/foot:<br />

350mA<br />

3000K 480 lm/ft<br />

3500K 510 lm/ft<br />

4000K 533 lm/ft<br />

700mA<br />

3000K 959 lm/ft<br />

3500K 1019 lm/ft<br />

4000K 1065 lm/ft<br />

Voltage: 120V or 277V input voltage.<br />

Heat Sink: Extruded Aluminum Profile<br />

LED connections: Board mounted connectors.<br />

Drivers: available from several manufacturers.<br />

Drivers matched to run lengths and specific LED light<br />

engines.<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

Certification<br />

Testing Standards: Tested in accordance with IESL-<br />

M79-08<br />

RoHS Compliant<br />

Warranty: 3 year<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type B<br />

Metalumen: RM4D-2-T8-4-N-OL-S-E-1-277-N<br />

Northern Illumination Company<br />

2<br />

Wall<br />

Wall<br />

R1-07-12


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Bartco, IPR8MS Series<br />

Section 26500 Type: B1<br />

PROPOSED SUBSTITUTION: Metalumen, RM4D-2-T8-4-N-OL-Y-E-1-277-N<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

Date: 5/7/13<br />

By Jesse Smith - Glumac Lighting Studio<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks Fixture must have wrap lens<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


TYPE B1<br />

Ordering Guide<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

106 [4.2]<br />

102 [4.0]<br />

119 [4.7]<br />

119 [4.7]<br />

102 [4.0]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Part number example<br />

91 [3.6]<br />

115 [4.5]<br />

91 [3.6]<br />

120 [4.7]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant Recessed Drywall Recessed T-bar Surface Wall<br />

91 [3.6]<br />

95 [3.7]<br />

Dimensions and photometry see reverse.<br />

RM4D 2S T5 12 N SL RD A E 1 347 N<br />

Model<br />

RM4D<br />

Number of<br />

Lamps<br />

Lamp<br />

Type<br />

Length<br />

Control<br />

Up<br />

N<br />

Control<br />

Down<br />

Mounting<br />

Finish<br />

Ballast<br />

Driver<br />

Circuitry Voltage Options<br />

No. of Lamps Length Control Up<br />

1<br />

1 Lamp<br />

1S<br />

1<br />

Staggered*<br />

1L<br />

1 LED<br />

2<br />

2 Lamps*<br />

2S<br />

2<br />

Staggered*<br />

*(T8 with opal<br />

satin lens<br />

only)<br />

Lamp Type<br />

4<br />

4 Foot<br />

8<br />

8 Foot<br />

12<br />

12 Foot<br />

R<br />

Continuous<br />

Length<br />

(consult<br />

factory)<br />

(fixtures<br />

supplied in<br />

nominal 1’<br />

increments only)<br />

T8 32W<br />

T5 28W<br />

T5HO 54W<br />

LED30K* 3000k<br />

LED35K* 3500k<br />

LED40K* 4000k<br />

*available with opal satin lens only<br />

N<br />

None<br />

Control<br />

Down<br />

SL<br />

Specular<br />

Parabolic<br />

Louver<br />

SSL<br />

Semi<br />

Specular<br />

Parabolic<br />

Louver<br />

OL<br />

Opal Satin<br />

Lens<br />

A<br />

Asymmetrical<br />

reflector<br />

(single T5,<br />

T5HO, T8 only)<br />

Mounting Ballast Circuitry Voltage Options<br />

Pendant<br />

Y<br />

Yoke Aircraft<br />

Cable<br />

RT<br />

Recessed<br />

T-Bar<br />

RD<br />

Recessed<br />

Drywall<br />

S<br />

Surface<br />

W<br />

Wall<br />

Finish<br />

A<br />

Anodized<br />

Aluminum<br />

C<br />

Custom<br />

For custom<br />

Finish specify<br />

RAL#<br />

Standard<br />

E<br />

Electronic Instant Start T8<br />

Programmed Rapid Start -T5/T5HO<br />

Dimming 120V/277V Dimming<br />

D1 Advance Mark 7<br />

(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />

D2 Advance Mark 10<br />

(1/2 Lamp T8, 1/2 Lamp T5HO)<br />

D4 Lutron Hi-lume<br />

(1/2 Lamp T8, T5HO)<br />

D5 Lutron Eco-<strong>System</strong><br />

(T5-T5HO-T8) (347V available)<br />

(some lamp/ballast cominations may<br />

not be available — consult factory for<br />

availability)<br />

Battery Pack Options<br />

BN1 Bodine B50LP (T8)<br />

BN2 Bodine LP400 (T8)<br />

BN3 Bodine LP500 (T5)<br />

BN4 Bodine LP600 (T5/T5HO/T8)<br />

1<br />

1 Circuit<br />

(Standard)<br />

AB*<br />

Alternating<br />

Switching<br />

EN*<br />

Emergency/<br />

Night Light<br />

LED Driver<br />

/LR*<br />

Left-right<br />

Switching<br />

*n/a for LED<br />

120<br />

277<br />

347*<br />

*(not<br />

available<br />

for LED)<br />

N<br />

None<br />

D<br />

Daylight<br />

Sensor<br />

O<br />

Occupancy<br />

Sensor<br />

DOS<br />

Daylight/<br />

Occupancy<br />

Sensor<br />

Maximum fixture lumens/foot<br />

Standard Dimming 3000k 3500k 4000k<br />

S350 (350mA) D350 (350mA) 480 510 533<br />

S700 (700mA) D700 (700mA) 959 1019 1065<br />

Approvals<br />

R1-07-12<br />

570 Southgate Drive, Guelph, Ontario N1G 4P6<br />

Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />

T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />

www.metalumen.com<br />

(UO) Signature Straub Hall - Deferred Maintenance<br />

Type B1<br />

Metalumen: RM4D-2-T8-4-N-OL-Y-E-1-277-N<br />

Northern Date Illumination Company<br />

1


TYPE B1<br />

Ordering Guide<br />

SPECIFICATIONS<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

CONSTRUCTION SPECIFICATIONS<br />

HOUSING<br />

Rigid extruded aluminum body, 2.0mm [0.08”]<br />

nominal wall thickness. 95mm [3.7”] width x 102mm<br />

[4.0”] high (Pendant/Wall/Surface)<br />

115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />

End Caps: C.R.S.<br />

FINISH<br />

Anodized aluminum, Custom finishes available.<br />

T8, T5, T5HO<br />

102 [4.0]<br />

LED<br />

102 [4.0]<br />

LIGHTING CONTROL OPTIONS<br />

Specular or semi specular parabolic louvre<br />

High transmittance snap in satin lens<br />

Asymmetrical reflector — single lamp only — open<br />

bottom<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

MOUNTING<br />

PENDANT<br />

Steel aircraft cable yoke complete with a Quick-Grip<br />

field adjustable suspension system provides for quick<br />

and easy onsite alignment.<br />

119 [4.7]<br />

119 [4.7]<br />

RECESSED<br />

T-Bar — Mounting clips supplied<br />

Drywall — Mounting brackets supplied<br />

WALL<br />

Wall brackets supplied<br />

SURFACE<br />

Direct to surface mount<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

LED/DRIVER SPECIFICATIONS<br />

Medium power LED’s<br />

Color temperatures available: 3000K, 3500K, 4000K<br />

CRI: 84 (4000K) (80 minimum)<br />

Nominal power consumption: 15W - 700mA, 7.5W -<br />

350mA<br />

Hours: 50,000<br />

Maximum delivered lumens/foot:<br />

350mA<br />

3000K 480 lm/ft<br />

3500K 510 lm/ft<br />

4000K 533 lm/ft<br />

700mA<br />

3000K 959 lm/ft<br />

3500K 1019 lm/ft<br />

4000K 1065 lm/ft<br />

Voltage: 120V or 277V input voltage.<br />

Heat Sink: Extruded Aluminum Profile<br />

LED connections: Board mounted connectors.<br />

Drivers: available from several manufacturers.<br />

Drivers matched to run lengths and specific LED light<br />

engines.<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

Certification<br />

Testing Standards: Tested in accordance with IESL-<br />

M79-08<br />

RoHS Compliant<br />

Warranty: 3 year<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type B1<br />

Metalumen: RM4D-2-T8-4-N-OL-Y-E-1-277-N<br />

Northern Illumination Company<br />

2<br />

Wall<br />

Wall<br />

R1-07-12


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Portfolio, LD4 Series<br />

Section 26500 Type: D<br />

PROPOSED SUBSTITUTION: Omega, OM4LED28277-R4LED40KHZ<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

ByJesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


application<br />

<br />

Philips Omega Revelation LED downlight utilizes<br />

proprietary remote phosphor technology to produce<br />

one of the most efficient and advanced LED systems<br />

available for general illumination.<br />

light engine<br />

<br />

<br />

<br />

<br />

<br />

<br />

phosphor technology provides increased efficiency<br />

and color stability by redirecting back reflected light.<br />

The phosphor lens assembly converts high brightness<br />

blue light into white light for an even diffused pattern,<br />

eliminating bright spots often created by individual LEDs.<br />

This technology provides consistent, stable color with<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

supply is overload and short circuit protected as well<br />

as thermally regulated to prevent overheating. Sound<br />

<br />

<br />

hours.<br />

<br />

<br />

construction<br />

<br />

<br />

heat sink allows for easy and tool less installation to<br />

the housing yoke. The heat sink is designed to properly<br />

<br />

applications to provide reliable performance over the life<br />

of the light engine. The heat sink incorporates alignment<br />

tabs to properly position with the housing. Rust resistant<br />

springs are used to secure the reflector to the light<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

". Yoke supports weight of heat sink<br />

and light engine assembly to prevent stress on finished<br />

reflector.<br />

<br />

are self flanged and snap to heat sink for consistent<br />

<br />

visual cutoff to source and source image.<br />

<br />

provide vertical and horizontal adjustments. These allow<br />

<br />

" <br />

alignment in 24" O.C. grid systems.<br />

<br />

<br />

inspection below ceiling.<br />

<br />

maintenance of complete system below ceiling.<br />

Removing reflector provides easy access to heat sink and<br />

light engine assembly. This assembly may be removed by<br />

depressing the springs which attach to the yoke and then<br />

simply opening protective cover and unplugging the push<br />

in connector from the LED board.<br />

listings & warranty<br />

TYPE D<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

4" LED 1500 Lumen Downlight<br />

Project<br />

Type<br />

<br />

Comments<br />

<br />

RV11-6.1<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

R4LED<br />

Family<br />

OM4LED<br />

<br />

Wattage<br />

Voltage<br />

120 <br />

<br />

277 <br />

<br />

347 Stepdown<br />

<br />

Option<br />

28 EM – Bodine<br />

<br />

Backup <br />

<br />

– 4" Reflector<br />

CCT<br />

<br />

<br />

<br />

<br />

CS – Clear Specular<br />

CSS <br />

Specular<br />

HZ <br />

GS <br />

WT <br />

PW – Pewter<br />

BZ – Bronze<br />

WH <br />

FF – Finish Flange<br />

<br />

<br />

in emergency mode <br />

<br />

Lumen output varies depending on CCT.<br />

<br />

<br />

<br />

<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type D<br />

Omega: OM4LED28277-R4LED40KHZ<br />

Northern Illumination Company


RV11-6.1<br />

<br />

TYPE D<br />

4" LED 1500 Lumen Downlight<br />

energy data<br />

<br />

<br />

<br />

<br />

dimensions<br />

24-15/16"<br />

(633.7mm)<br />

C<br />

C<br />

6-3/16"<br />

(152.4mm)<br />

10"<br />

(254.7mm)<br />

4-1/2"<br />

(115.1mm)<br />

5-1/8"<br />

(130.1mm)<br />

5-13/16"<br />

(146.9mm)<br />

1-15/16"<br />

(33.7mm)<br />

photometrics<br />

OM4LED28120-R4LED35KCS<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Comp Yearly Energy Cost at<br />

<br />

<br />

45 Cross<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

45 Cross<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

pw <br />

RCR<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

www.omegalighting.com<br />

Canadian Division<br />

<br />

<br />

<br />

Specifications are subject to change without notice.<br />

<br />

lamps that contain small amounts of mercury. Such lamps are labeled,<br />

<br />

mercury must be disposed of in accordance with local requirements.<br />

<br />

(UO) Straub www.lamprecycle.org Hall - Deferred Maintenance<br />

Type D<br />

Omega: OM4LED28277-R4LED40KHZ<br />

Northern Illumination Company


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Portfolio, LD4 Series<br />

Section 26500 Type: D1<br />

PROPOSED SUBSTITUTION: Omega, OM4LED28277-R4LED40KWWHZ<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

ByJesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


application<br />

• Philips Omega Revelation LED downlight utilizes with<br />

the proprietary remote phosphor technology to produce<br />

one of the most efficient and advanced LED systems<br />

available for general illumination.<br />

light engine<br />

• Philips Omega mixing chamber/optical assembly: Remote<br />

phosphor technology provides increased efficiency<br />

and color stability by redirecting back reflected light.<br />

The phosphor lens assembly converts high brightness<br />

blue light into white light for an even diffused pattern,<br />

eliminating bright spots often created by individual LEDs.<br />

This technology provides consistent, stable color with<br />

CCT color control of +/- 100K over the life of the light<br />

engine and provides 20% higher efficiency.<br />

• LED Array: The LED Array consists of a metal core<br />

circuit board with 16 high brightness royal blue LEDs.<br />

• Color: Available in three CCT options, 3000K, 3500K or<br />

4000K with 80CRI +/-2%.<br />

• Electrical: The power supply/driver features Advance<br />

Intelli-volt 120-277VAC 50/60hz, standard dimming<br />

driver with 0-10V analog dimming capability. The power<br />

supply is overload and short circuit protected as well<br />

as thermally regulated to prevent overheating. Sound<br />

rating A. Refer to dimming compatibility spec sheet for<br />

complete details. Driver has rated lifetime of 50,000<br />

hours.<br />

• Lifetime/Lumen Maintenance: 50,000 hour lifetime at<br />

70% lumen maintenance light engine.<br />

construction<br />

• Thermal Management: A proprietary die-cast aluminum<br />

heat sink allows for easy and tool less installation to<br />

the housing yoke. The heat sink is designed to properly<br />

maintain junction temperatures in recessed Non-IC<br />

applications to provide reliable performance over the life<br />

of the light engine. The heat sink incorporates alignment<br />

tabs to properly position with the housing. Rust resistant<br />

springs are used to secure the reflector to the light<br />

engine. Fixtures should not operated or exceed ambient<br />

temperature above 40˚C.<br />

TYPE D1<br />

• Housing: Precision die stamped 18ga galvanized steel<br />

mounting pan and yoke assembly. Allows for ceiling<br />

thickness up to 1-3/8". Yoke supports weight of heat sink<br />

and light engine assembly to prevent stress on finished<br />

reflector.<br />

• Reflector: Precision spun .050 aluminum reflectors<br />

are self flanged and snap to heat sink for consistent<br />

alignment to the optical assembly. Provides 50 degree<br />

visual cutoff to source and source image.<br />

• C-Channels: Revelation C-Channels are included and<br />

provide vertical and horizontal adjustments. These allow<br />

for fast and adjustment free installation in T-bar ceilings<br />

with 1/2" tile. C-Channels simply snap on grid for proper<br />

alignment in 24" O.C. grid systems.<br />

• Junction Box: 16 ga galvanized steel. UL listed for 8 No.<br />

12 AWG, 90C through branch circuit conductors. Allows<br />

inspection below ceiling.<br />

• Service: Modular construction allows for easy<br />

maintenance of complete system below ceiling.<br />

Removing reflector provides easy access to heat sink and<br />

light engine assembly. This assembly may be removed by<br />

depressing the springs which attach to the yoke and then<br />

simply opening protective cover and unplugging the push<br />

in connector from the LED board.<br />

listings & warranty<br />

• ETL, cUL Listed (Suitable for wet location applications.)<br />

• LED life calculations are based upon application junction<br />

temperatures an driver currents at or below IESNA -<br />

LM-80-08 manufacturer’s test data. IES test performed<br />

per IESNA - LM-79-08.<br />

• 5 year Warranty<br />

Architectural Downlighting<br />

OM4LED<br />

4" LED 1500 Lumen Wall Wash<br />

Project<br />

Type<br />

Model No.<br />

Comments<br />

Specifier’s Reference<br />

RV11-6.2<br />

Rev. 4/12<br />

Green Choice: OM4LED28120-R4LED30KWWCS<br />

HOUSING<br />

LIGHT ENGINE - REFLECTOR<br />

OM4LED<br />

28 R4LED WW<br />

–<br />

Family<br />

OM4LED<br />

4 inch housing<br />

Footnotes<br />

Wattage<br />

28 – 28 Input Watts<br />

Voltage<br />

120 - 120 VAC<br />

50/60Hz<br />

277 - 277 VAC<br />

50/60Hz<br />

347 - Stepdown<br />

(347:120/277)<br />

Option<br />

EM – Bodine BSL17C<br />

Emergency Back-up 1<br />

1. Delivered lumen output in emergency mode ranges from 500-550 lumens.<br />

Omega Reflector<br />

R4LED – 4" Reflector<br />

CCT<br />

30K – 3000K<br />

35K – 3500K<br />

40K – 4000K<br />

Reflector Type<br />

WW – Wall Wash<br />

Reflector Finish<br />

CS – Clear Specular<br />

CSS – Clear Semi-<br />

Specular<br />

HZ – Haze<br />

GS – Gold Specular<br />

WT – Wheat<br />

PW – Pewter<br />

BZ – Bronze<br />

WH – White, Paint<br />

FF – Finish Flange<br />

(as suffix to color)<br />

General Notes<br />

Lumen output varies depending on CCT.<br />

Refer to specific IES files for details.<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type D1<br />

Omega: OM4LED28277-R4LED40KWWHZ<br />

Northern Illumination Company


RV11-6.2<br />

Rev.4/12<br />

TYPE D1<br />

4" LED 1500 Lumen Wall Wash<br />

energy data<br />

Input Input Drive Input LED THD Power<br />

Voltage Current Current Power Power % Factor<br />

120 0.234 520mA 28 25 0.9<br />

277 0.101 520mA 28 25 0.9<br />

dimensions<br />

24-15/16"<br />

(633.7mm)<br />

C<br />

C<br />

6-3/16"<br />

(157.2mm)<br />

10"<br />

(254.7mm)<br />

ceiling cutout<br />

4-1/2"<br />

(115.1mm)<br />

5-1/8"<br />

(130.1mm)<br />

1-15/16"<br />

(33.7mm)<br />

5-13/16"<br />

(146.9mm)<br />

photometrics<br />

Consult factory for photometrics.<br />

©2012 Philips Omega<br />

All rights reserved.<br />

776 South Green Street • Tupelo, MS 38804<br />

p. 800.234.1890 • f. 662.841.5501<br />

www.omegalighting.com<br />

Canadian Division<br />

189 Bullock Drive • Markham, Ontario L3P 1W4<br />

p. 905.294.9570 • f. 905.294.9811<br />

Contact Factory for Additional Configurations.<br />

Specifications are subject to change without notice.<br />

Some luminaires use fluorescent or high intensity discharge (HID)<br />

lamps that contain small amounts of mercury. Such lamps are labeled,<br />

“Contain Mercury” and/or the symbol “HG”. Lamps that contain<br />

mercury must be disposed of in accordance with local requirements.<br />

(UO) Straub Information Hall regarding - Deferred lamp recycling Maintenance and disposal can be found at<br />

www.lamprecycle.org<br />

Type D1<br />

Omega: OM4LED28277-R4LED40KWWHZ<br />

Northern Illumination Company


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Arch Ltg Works, Lightplane Series<br />

Section 26500 Type: G<br />

PROPOSED SUBSTITUTION: Linear, WW6-D-1-ET5-SBL-G-NO-4<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

ByJesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks Must be T8 lamping<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


TYPE G<br />

Wall Wash WW6<br />

one or two T5 or T5HO lamps<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type G<br />

Linear: WW6-D-1-ET5-SBL-G-NO-4<br />

Northern Illumination Company


T5 options<br />

Wall Wash WW6<br />

TYPE G<br />

2T5 Wall Wash<br />

3 1 /2” H. x 4 1 /4” W.<br />

2 7 /8” aperture<br />

1T5 Surface Mount Wall Wash<br />

3 1 /8” H. x 3 11 /16” W.<br />

2 5 /16” aperture<br />

1T5 Wall Wash<br />

3 1 /8” H. x 3 11 /16” W.<br />

2 5 /16” aperture<br />

F<br />

Flanged<br />

L<br />

Flangeless<br />

SS<br />

Donn Fineline<br />

G<br />

1” T-bar (4 3 /4” H)<br />

NFG<br />

9<br />

/16” T-bar (4 3 /4”H)<br />

End View Fixture Detail. T’s only are installed perpendicular to lamps. Ceiling tile lays on integral fixture flange.<br />

For design use only. Not for construction. See www.linearltg.com for engineering drawings specific to job.<br />

ae whte steel hosn<br />

or T5T5HO lamps<br />

alale wth sanlaste lens <br />

or parallel lae loer <br />

3<br />

4”H. x 7 8” OC .<br />

ator prewre<br />

C laels<br />

T5 weht per oot 3 ls. approx.<br />

T5 weht per oot 3.5 ls. approx.<br />

90° Plane<br />

WW6-1T5-NS<br />

Efficiency: 62%<br />

Max. candlepower at 30°: 2150<br />

1911 1433 956 478 478 956 1433 1911<br />

90° 270°<br />

60° 300°<br />

30° 350°<br />

0°<br />

See www.linearltg.com for complete photometrics.<br />

Catalog No. Dir. Lamps Ballast Voltage Shielding Mounting Color Add'l options Row length<br />

WW6 - D- 4 - -xxx - - - BW - xxx - xx<br />

Fixture<br />

Lamps & Electrical Options<br />

Direction Direct<br />

Lamps 1 or 2<br />

Ballast ET5 Electronic T5<br />

ET5HO High Output T5<br />

Voltage 120 or 277<br />

347<br />

Offering T5 Lamping<br />

* Dimming ballasts may not be available for all T5/T5HO lamp lengths. Consult factory.<br />

** EM packs may not be available for all T5/T5HO lamp lengths. Consult factory.<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type G<br />

Linear: WW6-D-1-ET5-SBL-G-NO-4<br />

See www.linearltg.com for IES files and additional information.<br />

Northern Illumination Company<br />

Mechanical & Aesthetic Options<br />

Shielding NS No Shielding<br />

SBL Sandblasted Lens<br />

PRL Parallel Blade Louver<br />

Mounting G 1” T-bar<br />

NFG 9<br />

/16” T-bar<br />

SS Donn Fineline<br />

F Flanged<br />

L Flangeless<br />

SMT Surface<br />

Color BW Baked White<br />

Add'l<br />

Feet<br />

NO No Option<br />

Fixture<br />

CB Checkerboard Circuit“A”or“B” lengths<br />

EC Emergency Circuit<br />

Grid<br />

ED Electronic Dimming * 2’, 3’,<br />

EM Emergency Ballast** 4’, 5’<br />

FU Fusing<br />

Flanged and<br />

LO Louver Overlay<br />

Flangeless<br />

LS LutronEcoSys Sensor Feed 2’, 3’, 4’,<br />

NL Night Light<br />

5’, 6’, 8’<br />

PBPS Premium Blst Prog Start<br />

SC Separate Circuits<br />

WP 6ft Long Whip<br />

SF Special Feature<br />

please define<br />

Linear Lighting Corp.<br />

31-30 Hunters Point Ave., Long Island City, NY 11101 ©9/10<br />

718-361-7552 Fax 718-937-2747 Web: www.linearltg.com


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Alight, Accolade Series<br />

Section 26500 Type: H<br />

PROPOSED SUBSTITUTION: Metalumen, RM4D-1L-LED40K-2-OL-(RT OR RD)-X-D350-1-<br />

277-N<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

By<br />

Jesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks We would want to see a sample of<br />

the LED fixture for final approval<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


TYPE H<br />

Ordering Guide<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

106 [4.2]<br />

102 [4.0]<br />

119 [4.7]<br />

119 [4.7]<br />

102 [4.0]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Part number example<br />

91 [3.6]<br />

115 [4.5]<br />

91 [3.6]<br />

120 [4.7]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant Recessed Drywall Recessed T-bar Surface Wall<br />

91 [3.6]<br />

95 [3.7]<br />

Dimensions and photometry see reverse.<br />

RM4D 2S T5 12 N SL RD A E 1 347 N<br />

Model<br />

RM4D<br />

Number of<br />

Lamps<br />

Lamp<br />

Type<br />

Length<br />

Control<br />

Up<br />

N<br />

Control<br />

Down<br />

Mounting<br />

Finish<br />

Ballast<br />

Driver<br />

Circuitry Voltage Options<br />

No. of Lamps Length Control Up<br />

1<br />

1 Lamp<br />

1S<br />

1<br />

Staggered*<br />

1L<br />

1 LED<br />

2<br />

2 Lamps*<br />

2S<br />

2<br />

Staggered*<br />

*(T8 with opal<br />

satin lens<br />

only)<br />

4<br />

4 Foot<br />

8<br />

8 Foot<br />

12<br />

12 Foot<br />

R<br />

Continuous<br />

Length<br />

2 = 2 Foot<br />

(consult<br />

factory)<br />

(fixtures<br />

supplied in<br />

nominal 1’<br />

increments only)<br />

Lamp Type<br />

T8 32W<br />

T5 28W<br />

T5HO 54W<br />

LED30K* 3000k<br />

LED35K* 3500k<br />

LED40K* 4000k<br />

*available with opal satin lens only<br />

N<br />

None<br />

Control<br />

Down<br />

SL<br />

Specular<br />

Parabolic<br />

Louver<br />

SSL<br />

Semi<br />

Specular<br />

Parabolic<br />

Louver<br />

OL<br />

Opal Satin<br />

Lens<br />

A<br />

Asymmetrical<br />

reflector<br />

(single T5,<br />

T5HO, T8 only)<br />

Mounting Ballast Circuitry Voltage Options<br />

Pendant<br />

Y<br />

Yoke Aircraft<br />

Cable<br />

RT<br />

Recessed<br />

T-Bar<br />

RD<br />

Recessed<br />

Drywall<br />

S<br />

Surface<br />

W<br />

Wall<br />

Finish<br />

A<br />

Anodized<br />

Aluminum<br />

C<br />

Custom<br />

For custom<br />

Finish specify<br />

RAL#<br />

Standard<br />

E<br />

Electronic Instant Start T8<br />

Programmed Rapid Start -T5/T5HO<br />

Dimming 120V/277V Dimming<br />

D1 Advance Mark 7<br />

(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />

D2 Advance Mark 10<br />

(1/2 Lamp T8, 1/2 Lamp T5HO)<br />

D4 Lutron Hi-lume<br />

(1/2 Lamp T8, T5HO)<br />

D5 Lutron Eco-<strong>System</strong><br />

(T5-T5HO-T8) (347V available)<br />

(some lamp/ballast cominations may<br />

not be available — consult factory for<br />

availability)<br />

Battery Pack Options<br />

BN1 Bodine B50LP (T8)<br />

BN2 Bodine LP400 (T8)<br />

BN3 Bodine LP500 (T5)<br />

BN4 Bodine LP600 (T5/T5HO/T8)<br />

1<br />

1 Circuit<br />

(Standard)<br />

AB*<br />

Alternating<br />

Switching<br />

EN*<br />

Emergency/<br />

Night Light<br />

LED Driver<br />

/LR*<br />

Left-right<br />

Switching<br />

*n/a for LED<br />

120<br />

277<br />

347*<br />

*(not<br />

available<br />

for LED)<br />

N<br />

None<br />

D<br />

Daylight<br />

Sensor<br />

O<br />

Occupancy<br />

Sensor<br />

DOS<br />

Daylight/<br />

Occupancy<br />

Sensor<br />

Maximum fixture lumens/foot<br />

Standard Dimming 3000k 3500k 4000k<br />

S350 (350mA) D350 (350mA) 480 510 533<br />

S700 (700mA) D700 (700mA) 959 1019 1065<br />

Approvals<br />

R1-07-12<br />

570 Southgate Drive, Guelph, Ontario N1G 4P6<br />

Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />

T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />

www.metalumen.com<br />

1<br />

(UO) Signature Straub Hall - Deferred Maintenance<br />

Type H<br />

Metalumen: RM4D-1L-LED40K-2-OL-(RT OR RD)-X-<br />

D350-1-277-N<br />

Date<br />

Northern Illumination Company


TYPE H<br />

Ordering Guide<br />

SPECIFICATIONS<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

CONSTRUCTION SPECIFICATIONS<br />

HOUSING<br />

Rigid extruded aluminum body, 2.0mm [0.08”]<br />

nominal wall thickness. 95mm [3.7”] width x 102mm<br />

[4.0”] high (Pendant/Wall/Surface)<br />

115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />

End Caps: C.R.S.<br />

FINISH<br />

Anodized aluminum, Custom finishes available.<br />

T8, T5, T5HO<br />

102 [4.0]<br />

LED<br />

102 [4.0]<br />

LIGHTING CONTROL OPTIONS<br />

Specular or semi specular parabolic louvre<br />

High transmittance snap in satin lens<br />

Asymmetrical reflector — single lamp only — open<br />

bottom<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

MOUNTING<br />

PENDANT<br />

Steel aircraft cable yoke complete with a Quick-Grip<br />

field adjustable suspension system provides for quick<br />

and easy onsite alignment.<br />

119 [4.7]<br />

119 [4.7]<br />

RECESSED<br />

T-Bar — Mounting clips supplied<br />

Drywall — Mounting brackets supplied<br />

WALL<br />

Wall brackets supplied<br />

SURFACE<br />

Direct to surface mount<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

LED/DRIVER SPECIFICATIONS<br />

Medium power LED’s<br />

Color temperatures available: 3000K, 3500K, 4000K<br />

CRI: 84 (4000K) (80 minimum)<br />

Nominal power consumption: 15W - 700mA, 7.5W -<br />

350mA<br />

Hours: 50,000<br />

Maximum delivered lumens/foot:<br />

350mA<br />

3000K 480 lm/ft<br />

3500K 510 lm/ft<br />

4000K 533 lm/ft<br />

700mA<br />

3000K 959 lm/ft<br />

3500K 1019 lm/ft<br />

4000K 1065 lm/ft<br />

Voltage: 120V or 277V input voltage.<br />

Heat Sink: Extruded Aluminum Profile<br />

LED connections: Board mounted connectors.<br />

Drivers: available from several manufacturers.<br />

Drivers matched to run lengths and specific LED light<br />

engines.<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

Certification<br />

Testing Standards: Tested in accordance with IESL-<br />

M79-08<br />

RoHS Compliant<br />

Warranty: 3 year<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type H<br />

Metalumen: RM4D-1L-LED40K-2-OL-(RT OR RD)-X-<br />

D350-1-277-N<br />

Northern Illumination Company<br />

102 [4.0]<br />

2<br />

91 [3.6]<br />

95 [3.7]<br />

Wall<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Wall<br />

R1-07-12


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Alight, Accolade Series<br />

Section 26500 Type: H1<br />

PROPOSED SUBSTITUTION: Metalumen, RM4D-1L-LED40K-4-OL-(RT OR RD)-X-D350-1-<br />

277-N<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

By<br />

Jesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks We would want to see a sample of<br />

the LED fixture for final approval<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


TYPE H1<br />

Ordering Guide<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

106 [4.2]<br />

102 [4.0]<br />

119 [4.7]<br />

119 [4.7]<br />

102 [4.0]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Part number example<br />

91 [3.6]<br />

115 [4.5]<br />

91 [3.6]<br />

120 [4.7]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant Recessed Drywall Recessed T-bar Surface Wall<br />

91 [3.6]<br />

95 [3.7]<br />

Dimensions and photometry see reverse.<br />

RM4D 2S T5 12 N SL RD A E 1 347 N<br />

Model<br />

RM4D<br />

Number of<br />

Lamps<br />

Lamp<br />

Type<br />

Length<br />

Control<br />

Up<br />

N<br />

Control<br />

Down<br />

Mounting<br />

Finish<br />

Ballast<br />

Driver<br />

Circuitry Voltage Options<br />

No. of Lamps Length Control Up<br />

1<br />

1 Lamp<br />

1S<br />

1<br />

Staggered*<br />

1L<br />

1 LED<br />

2<br />

2 Lamps*<br />

2S<br />

2<br />

Staggered*<br />

*(T8 with opal<br />

satin lens<br />

only)<br />

Lamp Type<br />

4<br />

4 Foot<br />

8<br />

8 Foot<br />

12<br />

12 Foot<br />

R<br />

Continuous<br />

Length<br />

(consult<br />

factory)<br />

(fixtures<br />

supplied in<br />

nominal 1’<br />

increments only)<br />

T8 32W<br />

T5 28W<br />

T5HO 54W<br />

LED30K* 3000k<br />

LED35K* 3500k<br />

LED40K* 4000k<br />

*available with opal satin lens only<br />

N<br />

None<br />

Control<br />

Down<br />

SL<br />

Specular<br />

Parabolic<br />

Louver<br />

SSL<br />

Semi<br />

Specular<br />

Parabolic<br />

Louver<br />

OL<br />

Opal Satin<br />

Lens<br />

A<br />

Asymmetrical<br />

reflector<br />

(single T5,<br />

T5HO, T8 only)<br />

Mounting Ballast Circuitry Voltage Options<br />

Pendant<br />

Y<br />

Yoke Aircraft<br />

Cable<br />

RT<br />

Recessed<br />

T-Bar<br />

RD<br />

Recessed<br />

Drywall<br />

S<br />

Surface<br />

W<br />

Wall<br />

Finish<br />

A<br />

Anodized<br />

Aluminum<br />

C<br />

Custom<br />

For custom<br />

Finish specify<br />

RAL#<br />

Standard<br />

E<br />

Electronic Instant Start T8<br />

Programmed Rapid Start -T5/T5HO<br />

Dimming 120V/277V Dimming<br />

D1 Advance Mark 7<br />

(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />

D2 Advance Mark 10<br />

(1/2 Lamp T8, 1/2 Lamp T5HO)<br />

D4 Lutron Hi-lume<br />

(1/2 Lamp T8, T5HO)<br />

D5 Lutron Eco-<strong>System</strong><br />

(T5-T5HO-T8) (347V available)<br />

(some lamp/ballast cominations may<br />

not be available — consult factory for<br />

availability)<br />

Battery Pack Options<br />

BN1 Bodine B50LP (T8)<br />

BN2 Bodine LP400 (T8)<br />

BN3 Bodine LP500 (T5)<br />

BN4 Bodine LP600 (T5/T5HO/T8)<br />

1<br />

1 Circuit<br />

(Standard)<br />

AB*<br />

Alternating<br />

Switching<br />

EN*<br />

Emergency/<br />

Night Light<br />

LED Driver<br />

/LR*<br />

Left-right<br />

Switching<br />

*n/a for LED<br />

120<br />

277<br />

347*<br />

*(not<br />

available<br />

for LED)<br />

N<br />

None<br />

D<br />

Daylight<br />

Sensor<br />

O<br />

Occupancy<br />

Sensor<br />

DOS<br />

Daylight/<br />

Occupancy<br />

Sensor<br />

Maximum fixture lumens/foot<br />

Standard Dimming 3000k 3500k 4000k<br />

S350 (350mA) D350 (350mA) 480 510 533<br />

S700 (700mA) D700 (700mA) 959 1019 1065<br />

Approvals<br />

R1-07-12<br />

570 Southgate Drive, Guelph, Ontario N1G 4P6<br />

Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />

T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />

www.metalumen.com<br />

1<br />

(UO) Straub Hall - Deferred Maintenance<br />

Signature<br />

Type H1<br />

Metalumen: RM4D-1L-LED40K-4-OL-(RT OR RD)-X-<br />

D350-1-277-N<br />

Date<br />

Northern Illumination Company


TYPE H1<br />

Ordering Guide<br />

SPECIFICATIONS<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

CONSTRUCTION SPECIFICATIONS<br />

HOUSING<br />

Rigid extruded aluminum body, 2.0mm [0.08”]<br />

nominal wall thickness. 95mm [3.7”] width x 102mm<br />

[4.0”] high (Pendant/Wall/Surface)<br />

115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />

End Caps: C.R.S.<br />

FINISH<br />

Anodized aluminum, Custom finishes available.<br />

T8, T5, T5HO<br />

102 [4.0]<br />

LED<br />

102 [4.0]<br />

LIGHTING CONTROL OPTIONS<br />

Specular or semi specular parabolic louvre<br />

High transmittance snap in satin lens<br />

Asymmetrical reflector — single lamp only — open<br />

bottom<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

MOUNTING<br />

PENDANT<br />

Steel aircraft cable yoke complete with a Quick-Grip<br />

field adjustable suspension system provides for quick<br />

and easy onsite alignment.<br />

119 [4.7]<br />

119 [4.7]<br />

RECESSED<br />

T-Bar — Mounting clips supplied<br />

Drywall — Mounting brackets supplied<br />

WALL<br />

Wall brackets supplied<br />

SURFACE<br />

Direct to surface mount<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

LED/DRIVER SPECIFICATIONS<br />

Medium power LED’s<br />

Color temperatures available: 3000K, 3500K, 4000K<br />

CRI: 84 (4000K) (80 minimum)<br />

Nominal power consumption: 15W - 700mA, 7.5W -<br />

350mA<br />

Hours: 50,000<br />

Maximum delivered lumens/foot:<br />

350mA<br />

3000K 480 lm/ft<br />

3500K 510 lm/ft<br />

4000K 533 lm/ft<br />

700mA<br />

3000K 959 lm/ft<br />

3500K 1019 lm/ft<br />

4000K 1065 lm/ft<br />

Voltage: 120V or 277V input voltage.<br />

Heat Sink: Extruded Aluminum Profile<br />

LED connections: Board mounted connectors.<br />

Drivers: available from several manufacturers.<br />

Drivers matched to run lengths and specific LED light<br />

engines.<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

Certification<br />

Testing Standards: Tested in accordance with IESL-<br />

M79-08<br />

RoHS Compliant<br />

Warranty: 3 year<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type H1<br />

Metalumen: RM4D-1L-LED40K-4-OL-(RT OR RD)-X-<br />

D350-1-277-N<br />

Northern Illumination Company<br />

102 [4.0]<br />

2<br />

91 [3.6]<br />

95 [3.7]<br />

Wall<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Wall<br />

R1-07-12


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Alight, Accolade Series<br />

Section 26500 Type: H2<br />

PROPOSED SUBSTITUTION: Metalumen, RM4D-1L-LED40K-4-OL-(RT OR RD)-X-D700-1-<br />

277-N<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

By<br />

Jesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks We would want to see a sample of<br />

the LED fixture for final approval<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


TYPE H2<br />

Ordering Guide<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

106 [4.2]<br />

102 [4.0]<br />

119 [4.7]<br />

119 [4.7]<br />

102 [4.0]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Part number example<br />

91 [3.6]<br />

115 [4.5]<br />

91 [3.6]<br />

120 [4.7]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant Recessed Drywall Recessed T-bar Surface Wall<br />

91 [3.6]<br />

95 [3.7]<br />

Dimensions and photometry see reverse.<br />

RM4D 2S T5 12 N SL RD A E 1 347 N<br />

Model<br />

RM4D<br />

Number of<br />

Lamps<br />

Lamp<br />

Type<br />

Length<br />

Control<br />

Up<br />

N<br />

Control<br />

Down<br />

Mounting<br />

Finish<br />

Ballast<br />

Driver<br />

Circuitry Voltage Options<br />

No. of Lamps Length Control Up<br />

1<br />

1 Lamp<br />

1S<br />

1<br />

Staggered*<br />

1L<br />

1 LED<br />

2<br />

2 Lamps*<br />

2S<br />

2<br />

Staggered*<br />

*(T8 with opal<br />

satin lens<br />

only)<br />

Lamp Type<br />

4<br />

4 Foot<br />

8<br />

8 Foot<br />

12<br />

12 Foot<br />

R<br />

Continuous<br />

Length<br />

(consult<br />

factory)<br />

(fixtures<br />

supplied in<br />

nominal 1’<br />

increments only)<br />

T8 32W<br />

T5 28W<br />

T5HO 54W<br />

LED30K* 3000k<br />

LED35K* 3500k<br />

LED40K* 4000k<br />

*available with opal satin lens only<br />

N<br />

None<br />

Control<br />

Down<br />

SL<br />

Specular<br />

Parabolic<br />

Louver<br />

SSL<br />

Semi<br />

Specular<br />

Parabolic<br />

Louver<br />

OL<br />

Opal Satin<br />

Lens<br />

A<br />

Asymmetrical<br />

reflector<br />

(single T5,<br />

T5HO, T8 only)<br />

Mounting Ballast Circuitry Voltage Options<br />

Pendant<br />

Y<br />

Yoke Aircraft<br />

Cable<br />

RT<br />

Recessed<br />

T-Bar<br />

RD<br />

Recessed<br />

Drywall<br />

S<br />

Surface<br />

W<br />

Wall<br />

Finish<br />

A<br />

Anodized<br />

Aluminum<br />

C<br />

Custom<br />

For custom<br />

Finish specify<br />

RAL#<br />

Standard<br />

E<br />

Electronic Instant Start T8<br />

Programmed Rapid Start -T5/T5HO<br />

Dimming 120V/277V Dimming<br />

D1 Advance Mark 7<br />

(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />

D2 Advance Mark 10<br />

(1/2 Lamp T8, 1/2 Lamp T5HO)<br />

D4 Lutron Hi-lume<br />

(1/2 Lamp T8, T5HO)<br />

D5 Lutron Eco-<strong>System</strong><br />

(T5-T5HO-T8) (347V available)<br />

(some lamp/ballast cominations may<br />

not be available — consult factory for<br />

availability)<br />

Battery Pack Options<br />

BN1 Bodine B50LP (T8)<br />

BN2 Bodine LP400 (T8)<br />

BN3 Bodine LP500 (T5)<br />

BN4 Bodine LP600 (T5/T5HO/T8)<br />

1<br />

1 Circuit<br />

(Standard)<br />

AB*<br />

Alternating<br />

Switching<br />

EN*<br />

Emergency/<br />

Night Light<br />

LED Driver<br />

/LR*<br />

Left-right<br />

Switching<br />

*n/a for LED<br />

120<br />

277<br />

347*<br />

*(not<br />

available<br />

for LED)<br />

N<br />

None<br />

D<br />

Daylight<br />

Sensor<br />

O<br />

Occupancy<br />

Sensor<br />

DOS<br />

Daylight/<br />

Occupancy<br />

Sensor<br />

Maximum fixture lumens/foot<br />

Standard Dimming 3000k 3500k 4000k<br />

S350 (350mA) D350 (350mA) 480 510 533<br />

S700 (700mA) D700 (700mA) 959 1019 1065<br />

Approvals<br />

R1-07-12<br />

570 Southgate Drive, Guelph, Ontario N1G 4P6<br />

Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />

T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />

www.metalumen.com<br />

1<br />

(UO) Signature Straub Hall - Deferred Maintenance<br />

Type H2<br />

Metalumen: RM4D-1L-LED40K-4-OL-(RT OR RD)-X-<br />

D700-1-277-N<br />

Date<br />

Northern Illumination Company


TYPE H2<br />

Ordering Guide<br />

SPECIFICATIONS<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

CONSTRUCTION SPECIFICATIONS<br />

HOUSING<br />

Rigid extruded aluminum body, 2.0mm [0.08”]<br />

nominal wall thickness. 95mm [3.7”] width x 102mm<br />

[4.0”] high (Pendant/Wall/Surface)<br />

115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />

End Caps: C.R.S.<br />

FINISH<br />

Anodized aluminum, Custom finishes available.<br />

T8, T5, T5HO<br />

102 [4.0]<br />

LED<br />

102 [4.0]<br />

LIGHTING CONTROL OPTIONS<br />

Specular or semi specular parabolic louvre<br />

High transmittance snap in satin lens<br />

Asymmetrical reflector — single lamp only — open<br />

bottom<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

MOUNTING<br />

PENDANT<br />

Steel aircraft cable yoke complete with a Quick-Grip<br />

field adjustable suspension system provides for quick<br />

and easy onsite alignment.<br />

119 [4.7]<br />

119 [4.7]<br />

RECESSED<br />

T-Bar — Mounting clips supplied<br />

Drywall — Mounting brackets supplied<br />

WALL<br />

Wall brackets supplied<br />

SURFACE<br />

Direct to surface mount<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

LED/DRIVER SPECIFICATIONS<br />

Medium power LED’s<br />

Color temperatures available: 3000K, 3500K, 4000K<br />

CRI: 84 (4000K) (80 minimum)<br />

Nominal power consumption: 15W - 700mA, 7.5W -<br />

350mA<br />

Hours: 50,000<br />

Maximum delivered lumens/foot:<br />

350mA<br />

3000K 480 lm/ft<br />

3500K 510 lm/ft<br />

4000K 533 lm/ft<br />

700mA<br />

3000K 959 lm/ft<br />

3500K 1019 lm/ft<br />

4000K 1065 lm/ft<br />

Voltage: 120V or 277V input voltage.<br />

Heat Sink: Extruded Aluminum Profile<br />

LED connections: Board mounted connectors.<br />

Drivers: available from several manufacturers.<br />

Drivers matched to run lengths and specific LED light<br />

engines.<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

Certification<br />

Testing Standards: Tested in accordance with IESL-<br />

M79-08<br />

RoHS Compliant<br />

Warranty: 3 year<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type H2<br />

Metalumen: RM4D-1L-LED40K-4-OL-(RT OR RD)-X-<br />

D700-1-277-N<br />

Northern Illumination Company<br />

102 [4.0]<br />

2<br />

91 [3.6]<br />

95 [3.7]<br />

Wall<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Wall<br />

R1-07-12


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Alight, Accolade Series<br />

Section 26500 Type: H3<br />

PROPOSED SUBSTITUTION: Metalumen, RM4D-1L-LED40K-2-OL-(RT OR RD)-X-D700-1-<br />

277-N<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

By<br />

Jesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks We would want to see a sample of<br />

the LED fixture for final approval<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


TYPE H3<br />

Ordering Guide<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

106 [4.2]<br />

102 [4.0]<br />

119 [4.7]<br />

119 [4.7]<br />

102 [4.0]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Part number example<br />

91 [3.6]<br />

115 [4.5]<br />

91 [3.6]<br />

120 [4.7]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant Recessed Drywall Recessed T-bar Surface Wall<br />

91 [3.6]<br />

95 [3.7]<br />

Dimensions and photometry see reverse.<br />

RM4D 2S T5 12 N SL RD A E 1 347 N<br />

Model<br />

RM4D<br />

Number of<br />

Lamps<br />

Lamp<br />

Type<br />

Length<br />

Control<br />

Up<br />

N<br />

Control<br />

Down<br />

Mounting<br />

Finish<br />

Ballast<br />

Driver<br />

Circuitry Voltage Options<br />

No. of Lamps Length Control Up<br />

1<br />

1 Lamp<br />

1S<br />

1<br />

Staggered*<br />

1L<br />

1 LED<br />

2<br />

2 Lamps*<br />

2S<br />

2<br />

Staggered*<br />

*(T8 with opal<br />

satin lens<br />

only)<br />

4<br />

4 Foot<br />

8<br />

8 Foot<br />

12<br />

12 Foot<br />

R<br />

Continuous<br />

Length<br />

2 = 2 Foot<br />

(consult<br />

factory)<br />

(fixtures<br />

supplied in<br />

nominal 1’<br />

increments only)<br />

Lamp Type<br />

T8 32W<br />

T5 28W<br />

T5HO 54W<br />

LED30K* 3000k<br />

LED35K* 3500k<br />

LED40K* 4000k<br />

*available with opal satin lens only<br />

N<br />

None<br />

Control<br />

Down<br />

SL<br />

Specular<br />

Parabolic<br />

Louver<br />

SSL<br />

Semi<br />

Specular<br />

Parabolic<br />

Louver<br />

OL<br />

Opal Satin<br />

Lens<br />

A<br />

Asymmetrical<br />

reflector<br />

(single T5,<br />

T5HO, T8 only)<br />

Mounting Ballast Circuitry Voltage Options<br />

Pendant<br />

Y<br />

Yoke Aircraft<br />

Cable<br />

RT<br />

Recessed<br />

T-Bar<br />

RD<br />

Recessed<br />

Drywall<br />

S<br />

Surface<br />

W<br />

Wall<br />

Finish<br />

A<br />

Anodized<br />

Aluminum<br />

C<br />

Custom<br />

For custom<br />

Finish specify<br />

RAL#<br />

Standard<br />

E<br />

Electronic Instant Start T8<br />

Programmed Rapid Start -T5/T5HO<br />

Dimming 120V/277V Dimming<br />

D1 Advance Mark 7<br />

(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />

D2 Advance Mark 10<br />

(1/2 Lamp T8, 1/2 Lamp T5HO)<br />

D4 Lutron Hi-lume<br />

(1/2 Lamp T8, T5HO)<br />

D5 Lutron Eco-<strong>System</strong><br />

(T5-T5HO-T8) (347V available)<br />

(some lamp/ballast cominations may<br />

not be available — consult factory for<br />

availability)<br />

Battery Pack Options<br />

BN1 Bodine B50LP (T8)<br />

BN2 Bodine LP400 (T8)<br />

BN3 Bodine LP500 (T5)<br />

BN4 Bodine LP600 (T5/T5HO/T8)<br />

1<br />

1 Circuit<br />

(Standard)<br />

AB*<br />

Alternating<br />

Switching<br />

EN*<br />

Emergency/<br />

Night Light<br />

LED Driver<br />

/LR*<br />

Left-right<br />

Switching<br />

*n/a for LED<br />

120<br />

277<br />

347*<br />

*(not<br />

available<br />

for LED)<br />

N<br />

None<br />

D<br />

Daylight<br />

Sensor<br />

O<br />

Occupancy<br />

Sensor<br />

DOS<br />

Daylight/<br />

Occupancy<br />

Sensor<br />

Maximum fixture lumens/foot<br />

Standard Dimming 3000k 3500k 4000k<br />

S350 (350mA) D350 (350mA) 480 510 533<br />

S700 (700mA) D700 (700mA) 959 1019 1065<br />

Approvals<br />

R1-07-12<br />

570 Southgate Drive, Guelph, Ontario N1G 4P6<br />

Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />

T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />

www.metalumen.com<br />

1<br />

(UO) Signature Straub Hall - Deferred Maintenance<br />

Type H3<br />

Metalumen: RM4D-1L-LED40K-2-OL-(RT OR RD)-X-<br />

D700-1-277-N<br />

Date<br />

Northern Illumination Company


TYPE H3<br />

Ordering Guide<br />

SPECIFICATIONS<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

CONSTRUCTION SPECIFICATIONS<br />

HOUSING<br />

Rigid extruded aluminum body, 2.0mm [0.08”]<br />

nominal wall thickness. 95mm [3.7”] width x 102mm<br />

[4.0”] high (Pendant/Wall/Surface)<br />

115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />

End Caps: C.R.S.<br />

FINISH<br />

Anodized aluminum, Custom finishes available.<br />

T8, T5, T5HO<br />

102 [4.0]<br />

LED<br />

102 [4.0]<br />

LIGHTING CONTROL OPTIONS<br />

Specular or semi specular parabolic louvre<br />

High transmittance snap in satin lens<br />

Asymmetrical reflector — single lamp only — open<br />

bottom<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

MOUNTING<br />

PENDANT<br />

Steel aircraft cable yoke complete with a Quick-Grip<br />

field adjustable suspension system provides for quick<br />

and easy onsite alignment.<br />

119 [4.7]<br />

119 [4.7]<br />

RECESSED<br />

T-Bar — Mounting clips supplied<br />

Drywall — Mounting brackets supplied<br />

WALL<br />

Wall brackets supplied<br />

SURFACE<br />

Direct to surface mount<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

LED/DRIVER SPECIFICATIONS<br />

Medium power LED’s<br />

Color temperatures available: 3000K, 3500K, 4000K<br />

CRI: 84 (4000K) (80 minimum)<br />

Nominal power consumption: 15W - 700mA, 7.5W -<br />

350mA<br />

Hours: 50,000<br />

Maximum delivered lumens/foot:<br />

350mA<br />

3000K 480 lm/ft<br />

3500K 510 lm/ft<br />

4000K 533 lm/ft<br />

700mA<br />

3000K 959 lm/ft<br />

3500K 1019 lm/ft<br />

4000K 1065 lm/ft<br />

Voltage: 120V or 277V input voltage.<br />

Heat Sink: Extruded Aluminum Profile<br />

LED connections: Board mounted connectors.<br />

Drivers: available from several manufacturers.<br />

Drivers matched to run lengths and specific LED light<br />

engines.<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

Certification<br />

Testing Standards: Tested in accordance with IESL-<br />

M79-08<br />

RoHS Compliant<br />

Warranty: 3 year<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type H3<br />

Metalumen: RM4D-1L-LED40K-2-OL-(RT OR RD)-X-<br />

D700-1-277-N<br />

Northern Illumination Company<br />

102 [4.0]<br />

2<br />

91 [3.6]<br />

95 [3.7]<br />

Wall<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Wall<br />

R1-07-12


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Bartco, IPR8MS Series<br />

Section 26500 Type: M<br />

PROPOSED SUBSTITUTION: Metalumen, RM4D-2-T8-4-N-OL-W-X-E-1-277-N<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

Date: 5/7/13<br />

By Jesse Smith - Glumac Lighting Studio<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks Fixture must have wrap lens<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


TYPE M<br />

Ordering Guide<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

106 [4.2]<br />

102 [4.0]<br />

119 [4.7]<br />

119 [4.7]<br />

102 [4.0]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Part number example<br />

91 [3.6]<br />

115 [4.5]<br />

91 [3.6]<br />

120 [4.7]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant Recessed Drywall Recessed T-bar Surface Wall<br />

91 [3.6]<br />

95 [3.7]<br />

Dimensions and photometry see reverse.<br />

RM4D 2S T5 12 N SL RD A E 1 347 N<br />

Model<br />

RM4D<br />

Number of<br />

Lamps<br />

Lamp<br />

Type<br />

Length<br />

Control<br />

Up<br />

N<br />

Control<br />

Down<br />

Mounting<br />

Finish<br />

Ballast<br />

Driver<br />

Circuitry Voltage Options<br />

No. of Lamps Length Control Up<br />

1<br />

1 Lamp<br />

1S<br />

1<br />

Staggered*<br />

1L<br />

1 LED<br />

2<br />

2 Lamps*<br />

2S<br />

2<br />

Staggered*<br />

*(T8 with opal<br />

satin lens<br />

only)<br />

Lamp Type<br />

4<br />

4 Foot<br />

8<br />

8 Foot<br />

12<br />

12 Foot<br />

R<br />

Continuous<br />

Length<br />

(consult<br />

factory)<br />

(fixtures<br />

supplied in<br />

nominal 1’<br />

increments only)<br />

T8 32W<br />

T5 28W<br />

T5HO 54W<br />

LED30K* 3000k<br />

LED35K* 3500k<br />

LED40K* 4000k<br />

*available with opal satin lens only<br />

N<br />

None<br />

Control<br />

Down<br />

SL<br />

Specular<br />

Parabolic<br />

Louver<br />

SSL<br />

Semi<br />

Specular<br />

Parabolic<br />

Louver<br />

OL<br />

Opal Satin<br />

Lens<br />

A<br />

Asymmetrical<br />

reflector<br />

(single T5,<br />

T5HO, T8 only)<br />

Mounting Ballast Circuitry Voltage Options<br />

Pendant<br />

Y<br />

Yoke Aircraft<br />

Cable<br />

RT<br />

Recessed<br />

T-Bar<br />

RD<br />

Recessed<br />

Drywall<br />

S<br />

Surface<br />

W<br />

Wall<br />

Finish<br />

A<br />

Anodized<br />

Aluminum<br />

C<br />

Custom<br />

For custom<br />

Finish specify<br />

RAL#<br />

Standard<br />

E<br />

Electronic Instant Start T8<br />

Programmed Rapid Start -T5/T5HO<br />

Dimming 120V/277V Dimming<br />

D1 Advance Mark 7<br />

(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />

D2 Advance Mark 10<br />

(1/2 Lamp T8, 1/2 Lamp T5HO)<br />

D4 Lutron Hi-lume<br />

(1/2 Lamp T8, T5HO)<br />

D5 Lutron Eco-<strong>System</strong><br />

(T5-T5HO-T8) (347V available)<br />

(some lamp/ballast cominations may<br />

not be available — consult factory for<br />

availability)<br />

Battery Pack Options<br />

BN1 Bodine B50LP (T8)<br />

BN2 Bodine LP400 (T8)<br />

BN3 Bodine LP500 (T5)<br />

BN4 Bodine LP600 (T5/T5HO/T8)<br />

1<br />

1 Circuit<br />

(Standard)<br />

AB*<br />

Alternating<br />

Switching<br />

EN*<br />

Emergency/<br />

Night Light<br />

LED Driver<br />

/LR*<br />

Left-right<br />

Switching<br />

*n/a for LED<br />

120<br />

277<br />

347*<br />

*(not<br />

available<br />

for LED)<br />

N<br />

None<br />

D<br />

Daylight<br />

Sensor<br />

O<br />

Occupancy<br />

Sensor<br />

DOS<br />

Daylight/<br />

Occupancy<br />

Sensor<br />

Maximum fixture lumens/foot<br />

Standard Dimming 3000k 3500k 4000k<br />

S350 (350mA) D350 (350mA) 480 510 533<br />

S700 (700mA) D700 (700mA) 959 1019 1065<br />

Approvals<br />

R1-07-12<br />

570 Southgate Drive, Guelph, Ontario N1G 4P6<br />

Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />

T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />

www.metalumen.com<br />

(UO) Straub Hall - Deferred Maintenance<br />

Signature<br />

Type M<br />

Metalumen: RM4D-2-T8-4-N-OL-W-X-E-1-277-N<br />

Northern Date Illumination Company<br />

1


TYPE M<br />

Ordering Guide<br />

SPECIFICATIONS<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

CONSTRUCTION SPECIFICATIONS<br />

HOUSING<br />

Rigid extruded aluminum body, 2.0mm [0.08”]<br />

nominal wall thickness. 95mm [3.7”] width x 102mm<br />

[4.0”] high (Pendant/Wall/Surface)<br />

115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />

End Caps: C.R.S.<br />

FINISH<br />

Anodized aluminum, Custom finishes available.<br />

T8, T5, T5HO<br />

102 [4.0]<br />

LED<br />

102 [4.0]<br />

LIGHTING CONTROL OPTIONS<br />

Specular or semi specular parabolic louvre<br />

High transmittance snap in satin lens<br />

Asymmetrical reflector — single lamp only — open<br />

bottom<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

MOUNTING<br />

PENDANT<br />

Steel aircraft cable yoke complete with a Quick-Grip<br />

field adjustable suspension system provides for quick<br />

and easy onsite alignment.<br />

119 [4.7]<br />

119 [4.7]<br />

RECESSED<br />

T-Bar — Mounting clips supplied<br />

Drywall — Mounting brackets supplied<br />

WALL<br />

Wall brackets supplied<br />

SURFACE<br />

Direct to surface mount<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

LED/DRIVER SPECIFICATIONS<br />

Medium power LED’s<br />

Color temperatures available: 3000K, 3500K, 4000K<br />

CRI: 84 (4000K) (80 minimum)<br />

Nominal power consumption: 15W - 700mA, 7.5W -<br />

350mA<br />

Hours: 50,000<br />

Maximum delivered lumens/foot:<br />

350mA<br />

3000K 480 lm/ft<br />

3500K 510 lm/ft<br />

4000K 533 lm/ft<br />

700mA<br />

3000K 959 lm/ft<br />

3500K 1019 lm/ft<br />

4000K 1065 lm/ft<br />

Voltage: 120V or 277V input voltage.<br />

Heat Sink: Extruded Aluminum Profile<br />

LED connections: Board mounted connectors.<br />

Drivers: available from several manufacturers.<br />

Drivers matched to run lengths and specific LED light<br />

engines.<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

Certification<br />

Testing Standards: Tested in accordance with IESL-<br />

M79-08<br />

RoHS Compliant<br />

Warranty: 3 year<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type M<br />

Metalumen: RM4D-2-T8-4-N-OL-W-X-E-1-277-N<br />

Northern Illumination Company<br />

2<br />

Wall<br />

Wall<br />

R1-07-12


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Arch Ltg Works, Up and Under Series<br />

Section 26500 Type: P<br />

PROPOSED SUBSTITUTION: Metalumen, RM4DI-2-T8-4-OL-OL-Y-E-1-277-N<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

By Jesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Please provide sample of the<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />

Grande family. Photometrics will<br />

also have to be calculated to show<br />

The Construction Specifications Institute performance is met September within the 1997<br />

Northwest Region<br />

classroom spaces.


TYPE P<br />

Ordering Guide<br />

Grande RM4DI<br />

Series<br />

T8, T5, T5H0 DIRECT/IDIRECT – Pendant, Wall<br />

TAB<br />

15<br />

106 [4.2]<br />

135 [5.3]<br />

135 [5.3]<br />

91 [3.6]<br />

91 [3.6]<br />

95 [3.7]<br />

95 [3.7]<br />

Pendant<br />

Wall<br />

Part number example<br />

RM4DI 3 T8 4 N SL Y A E 1 120 N<br />

Model<br />

RM4DI<br />

Number of<br />

Lamps<br />

Lamp<br />

Type<br />

Length<br />

Control<br />

Up<br />

Control<br />

Down<br />

Mounting<br />

Finish<br />

Ballast<br />

Driver<br />

Circuitry Voltage Options<br />

No. of Lamps Length Control Up<br />

2<br />

1 Up/1 Down<br />

2S<br />

1 Up/1 Down<br />

Staggered*<br />

2L<br />

1 Up/1 Down<br />

3<br />

1 Up/2 Down*<br />

3S<br />

1 Up/2 Down<br />

Staggered*<br />

4<br />

2 Up/2 Down*<br />

4S<br />

2 Up/2 Down<br />

Staggered*<br />

*(T8 with opal<br />

satin lens only)<br />

Lamp Type<br />

4<br />

4 Foot<br />

8<br />

8 Foot<br />

12<br />

12 Foot<br />

R<br />

Continuous<br />

Length<br />

(consult<br />

factory)<br />

(fixtures<br />

supplied in<br />

nominal 1’<br />

increments only)<br />

T8 32W<br />

T5 28W<br />

T5HO 54W<br />

LED30K* 3000k<br />

LED35K* 3500k<br />

LED40K* 4000k<br />

*available with opal satin lens only<br />

N<br />

None<br />

OL<br />

Opal<br />

Satin<br />

Lens<br />

Control<br />

Down<br />

SL<br />

Specular<br />

Parabolic<br />

Louver<br />

SSL<br />

Semi<br />

Specular<br />

Parabolic<br />

Louver<br />

OL<br />

Opal Satin<br />

Lens<br />

A<br />

Asymmetrical<br />

reflector<br />

(single T5,<br />

T5HO, T8 only)<br />

Mounting Ballast Circuitry Voltage Options<br />

Pendant<br />

Y<br />

Yoke<br />

Aircraft<br />

Cable<br />

W<br />

Wall<br />

Finish<br />

A Anodized<br />

Aluminum<br />

C Custom<br />

For custom<br />

Finish specify<br />

RAL#<br />

Standard<br />

E<br />

Electronic Instant Start T8<br />

Programmed Rapid Start -T5/T5HO<br />

Dimming 120V/277V Dimming<br />

D1 Advance Mark 7<br />

(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />

D2 Advance Mark 10<br />

(1/2 Lamp T8, 1/2 Lamp T5HO)<br />

D4 Lutron Hi-lume<br />

(1/2 Lamp T8, T5HO)<br />

D5 Lutron Eco-<strong>System</strong><br />

(T5-T5HO-T8) (347V available)<br />

(some lamp/ballast cominations may not be<br />

available — consult factory for availability)<br />

Battery Pack Options<br />

BN1 Bodine B50LP (T8)<br />

BN2 Bodine LP400 (T8)<br />

BN3 Bodine LP500 (T5)<br />

BN4 Bodine LP600 (T5/T5HO/T8)<br />

1<br />

1 Circuit<br />

(Standard)<br />

AB*<br />

Alternating<br />

Switching<br />

EN*<br />

Emergency/<br />

Night Light<br />

LED Driver<br />

/LR*<br />

Left-right<br />

Switching<br />

*n/a for LED<br />

120<br />

277<br />

347*<br />

*(not<br />

available<br />

for LED)<br />

N<br />

None<br />

D<br />

Daylight<br />

Sensor<br />

O<br />

Occupancy<br />

Sensor<br />

DOS<br />

Daylight/<br />

Occupancy<br />

Sensor<br />

Maximum fixture lumens/foot<br />

Standard Dimming 3000k 3500k 4000k<br />

S350 (350mA) D350 (350mA) 959 1019 1065<br />

S700 (700mA) D700 (700mA) 1918 2038 2130<br />

Approvals<br />

R1-07-12<br />

570 Southgate Drive, Guelph, Ontario N1G 4P6<br />

Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />

T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />

www.metalumen.com<br />

(UO) Signature Straub Hall - Deferred Maintenance<br />

Type P<br />

Metalumen: RM4DI-2-T8-4-OL-OL-Y-E-1-277-N<br />

Northern Date Illumination Company<br />

3


TYPE P<br />

Ordering Guide<br />

SPECIFICATIONS<br />

Grande RM4DI<br />

Series<br />

T8, T5, T5H0 DIRECT/IDIRECT – Pendant, Wall<br />

TAB<br />

15<br />

CONSTRUCTION SPECIFICATIONS<br />

T8, T5, T5HO<br />

LED<br />

HOUSING<br />

Rigid extruded aluminum body, 2.0mm [0.08”]<br />

nominal wall thickness. 95mm [3.7”] width x 135mm<br />

[5.3”] high<br />

End Caps: C.R.S.<br />

FINISH<br />

Anodized aluminum, Custom finishes available.<br />

LIGHTING CONTROL OPTIONS<br />

Specular or semi specular parabolic louvre<br />

High transmittance snap in satin lens<br />

Asymmetrical reflector — single lamp only — open<br />

bottom<br />

MOUNTING<br />

PENDANT<br />

Steel aircraft cable yoke complete with a Quick-Grip<br />

field adjustable suspension system provides for quick<br />

and easy onsite alignment.<br />

135 [5.3]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

135 [5.3]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

1<br />

WALL<br />

Wall brackets supplied<br />

106 [4.2]<br />

106 [4.2]<br />

LED/DRIVER SPECIFICATIONS<br />

Medium power LED’s<br />

Color temperatures available: 3000K, 3500K, 4000K<br />

CRI: 84 (4000k) (80 minimum)<br />

Nominal power consumption: 15W - 700mA, 7.5W -<br />

350mA<br />

Hours: 50,000<br />

Maximum delivered lumens/foot:<br />

350mA<br />

3000K 959 lm/ft<br />

3500K 1019 lm/ft<br />

4000K 1065 lm/ft<br />

700mA<br />

3000K 1918 lm/ft<br />

3500K 2038 lm/ft<br />

4000K 2130 lm/ft<br />

Voltage: 120V or 277V input voltage.<br />

Heat Sink: Extruded Aluminum Profile<br />

LED connections: Board mounted connectors.<br />

Drivers: available from several manufacturers.<br />

Drivers matched to run lengths and specific LED light<br />

engines.<br />

135 [5.3]<br />

Wall<br />

91 [3.6]<br />

95 [3.7]<br />

135 [5.3]<br />

Wall<br />

91 [3.6]<br />

95 [3.7]<br />

Certification<br />

Testing Standards: Tested in accordance with IESL-<br />

M79-08<br />

RoHS Compliant<br />

Warranty: 3 year<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type P<br />

Metalumen: RM4DI-2-T8-4-OL-OL-Y-E-1-277-N<br />

Northern Illumination Company<br />

4<br />

R1-07-12


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Portfolio, LD4 Series<br />

Section 26500 Type: SA<br />

PROPOSED SUBSTITUTION: Omega, OM4LED28277-R4LED40KHZ<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

By Jesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


application<br />

<br />

Philips Omega Revelation LED downlight utilizes<br />

proprietary remote phosphor technology to produce<br />

one of the most efficient and advanced LED systems<br />

available for general illumination.<br />

light engine<br />

<br />

<br />

<br />

<br />

<br />

<br />

phosphor technology provides increased efficiency<br />

and color stability by redirecting back reflected light.<br />

The phosphor lens assembly converts high brightness<br />

blue light into white light for an even diffused pattern,<br />

eliminating bright spots often created by individual LEDs.<br />

This technology provides consistent, stable color with<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

supply is overload and short circuit protected as well<br />

as thermally regulated to prevent overheating. Sound<br />

<br />

<br />

hours.<br />

<br />

<br />

construction<br />

<br />

<br />

heat sink allows for easy and tool less installation to<br />

the housing yoke. The heat sink is designed to properly<br />

<br />

applications to provide reliable performance over the life<br />

of the light engine. The heat sink incorporates alignment<br />

tabs to properly position with the housing. Rust resistant<br />

springs are used to secure the reflector to the light<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

". Yoke supports weight of heat sink<br />

and light engine assembly to prevent stress on finished<br />

reflector.<br />

<br />

are self flanged and snap to heat sink for consistent<br />

<br />

visual cutoff to source and source image.<br />

<br />

provide vertical and horizontal adjustments. These allow<br />

<br />

" <br />

alignment in 24" O.C. grid systems.<br />

<br />

<br />

inspection below ceiling.<br />

<br />

maintenance of complete system below ceiling.<br />

Removing reflector provides easy access to heat sink and<br />

light engine assembly. This assembly may be removed by<br />

depressing the springs which attach to the yoke and then<br />

simply opening protective cover and unplugging the push<br />

in connector from the LED board.<br />

listings & warranty<br />

TYPE SA<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

4" LED 1500 Lumen Downlight<br />

Project<br />

Type<br />

<br />

Comments<br />

<br />

RV11-6.1<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

R4LED<br />

Family<br />

OM4LED<br />

<br />

Wattage<br />

Voltage<br />

120 <br />

<br />

277 <br />

<br />

347 Stepdown<br />

<br />

Option<br />

28 EM – Bodine<br />

<br />

Backup <br />

<br />

– 4" Reflector<br />

CCT<br />

<br />

<br />

<br />

<br />

CS – Clear Specular<br />

CSS <br />

Specular<br />

HZ <br />

GS <br />

WT <br />

PW – Pewter<br />

BZ – Bronze<br />

WH <br />

FF – Finish Flange<br />

<br />

<br />

in emergency mode <br />

<br />

Lumen output varies depending on CCT.<br />

<br />

<br />

<br />

<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type SA<br />

Omega: OM4LED28277-R4LED40KHZ<br />

Northern Illumination Company


RV11-6.1<br />

<br />

TYPE SA<br />

4" LED 1500 Lumen Downlight<br />

energy data<br />

<br />

<br />

<br />

<br />

dimensions<br />

24-15/16"<br />

(633.7mm)<br />

C<br />

C<br />

6-3/16"<br />

(152.4mm)<br />

10"<br />

(254.7mm)<br />

4-1/2"<br />

(115.1mm)<br />

5-1/8"<br />

(130.1mm)<br />

5-13/16"<br />

(146.9mm)<br />

1-15/16"<br />

(33.7mm)<br />

photometrics<br />

OM4LED28120-R4LED35KCS<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Comp Yearly Energy Cost at<br />

<br />

<br />

45 Cross<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

45 Cross<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

pw <br />

RCR<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

www.omegalighting.com<br />

Canadian Division<br />

<br />

<br />

<br />

Specifications are subject to change without notice.<br />

<br />

lamps that contain small amounts of mercury. Such lamps are labeled,<br />

<br />

mercury must be disposed of in accordance with local requirements.<br />

<br />

www.lamprecycle.org<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type SA<br />

Omega: OM4LED28277-R4LED40KHZ<br />

Northern Illumination Company


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Portfolio, LD6 Series<br />

Section 26500 Type: SA1<br />

PROPOSED SUBSTITUTION: Omega, OM6LEDXX277DL-R6LED40KHZDL<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

By Jesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


application<br />

<br />

Philips Omega Revelation LED downlight utilizes the<br />

proprietary remote phosphor technology to produce<br />

one of the most efficient and advanced LED systems<br />

available for general illumination in retail, hospitality,<br />

office and institutional applications.<br />

light engine<br />

<br />

<br />

<br />

<br />

<br />

<br />

phosphor technology provides increased efficiency<br />

and color stability by redirecting back reflected light.<br />

Phosphor lens assembly converts high brightness royal<br />

blue light into white light for an even, diffused pattern,<br />

eliminating bright spots often created by individual LEDs.<br />

This technology provides consistent, stable color with<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

circuit protected as well as thermally regulated to<br />

<br />

<br />

visit www.lutron.com.<br />

<br />

<br />

construction<br />

<br />

<br />

<br />

the housing yoke. The heat sink is designed to properly<br />

<br />

applications to provide reliable performance over the life<br />

of the light engine. The heat sink incorporates alignment<br />

tabs to properly position with the housing. Rust resistant<br />

springs are used to secure the reflector to the light<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

and light engine assembly to prevent stress on finished<br />

reflector.<br />

<br />

<br />

of finishes available. White flange is standard. Optional<br />

<br />

to the catalog number. Optics are designed to provide a<br />

<br />

<br />

included and provide vertical and horizontal adjustments.<br />

These allow for fast and adjustment free installation in<br />

<br />

<br />

<br />

<br />

inspection below ceiling.<br />

<br />

maintenance of complete system below ceiling.<br />

Removing reflector provides easy access to heat sink and<br />

light engine assembly. This assembly may be removed<br />

<br />

then simply opening protective cover and unplugging the<br />

push in connector from the LED board.<br />

listings & warranty<br />

<br />

<br />

<br />

TYPE SA1<br />

<br />

<br />

<br />

<br />

<br />

<br />

Project<br />

Type<br />

<br />

Comments<br />

<br />

6" LED<br />

2000 Lumen Downlight<br />

with Lutron Hi Lume A Series<br />

<br />

RV11-11.1<br />

<br />

<br />

<br />

<br />

<br />

DL<br />

–<br />

<br />

DL<br />

Family<br />

OM6LED<br />

<br />

Wattage<br />

40 2<br />

27 <br />

20 4<br />

Voltage<br />

120 <br />

<br />

277 <br />

<br />

347 <br />

<br />

Driver<br />

<br />

<br />

Option<br />

EM – <br />

<br />

<br />

<br />

CCT<br />

<br />

<br />

<br />

<br />

CS <br />

CSS <br />

<br />

HZ <br />

GS <br />

WT – Wheat<br />

PW – Pewter<br />

BZ <br />

WH – White, Paint<br />

FF <br />

<br />

Dimming<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Lumen output varies depending on CCT,<br />

<br />

<br />

<br />

<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type SA1<br />

Omega: OM6LEDXX277DL-R6LED40KHZDL<br />

Northern Illumination Company


RV11-11.1 <br />

TYPE SA1<br />

6" LED 2000 Lumen Downlight<br />

energy data<br />

<br />

<br />

<br />

<br />

dimensions<br />

24-15/16"<br />

(633.7mm)<br />

A<br />

A<br />

7-1/8"<br />

(180.7mm)<br />

9-1/2"<br />

(228.6mm)<br />

ceiling<br />

cutout<br />

6"<br />

(151.8mm)<br />

6-3/8"<br />

(161.9mm)<br />

7-5/8"<br />

1-3/8"<br />

(34.9mm)<br />

photometrics<br />

OM6LED40120DL-R6LED30KCSDL<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

45 Cross<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

45 Cross<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

RCR<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

www.omegalighting.com<br />

Canadian Division<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

mercury must be disposed of in accordance with local requirements.<br />

<br />

www.lamprecycle.org<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type SA1<br />

Omega: OM6LEDXX277DL-R6LED40KHZDL<br />

Northern Illumination Company


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Winona, Step Series<br />

Section 26500 Type: SB<br />

PROPOSED SUBSTITUTION: Gardco, 941L-20LA-C-DG-NW-UNVI-BRP<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

By Jesse Smith - Glumac Lighting Studio<br />

Date: 5/7/13<br />

Date 5/20/2013<br />

Frosted glass is not preferred. LEDs<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />

need to be more discrete.<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


Job:<br />

Type:<br />

Notes:<br />

Page 1 of 3<br />

TYPE SB<br />

94 Line LED<br />

941L, 942L and 943L Step and Aisle Lights<br />

941L<br />

The Philips Gardco 941L, 942L and 943L recessed aisle lights are architecturally styled luminaires<br />

precisely constructed of die cast aluminum, providing light with high performance, long life LED systems.<br />

Retrofit kits are also available, making it possible to update installations of classic 941, 942 and 943<br />

Philips Gardco fluorescent and HID step lights to LED without the need to replace the back housing. A<br />

field adjustable junction box enhances design flexibility. Self-compensating silicone gasketing completely<br />

excludes moisture, insects and contaminants. A choice of three (3) architecturally designed faceplates<br />

allows for a variety of applications. The ribbed guard faceplate offers vandal protection for glass lenses.<br />

942L<br />

943L<br />

943L<br />

Mounted<br />

in Bollard<br />

PREFIX<br />

WALL TYPE<br />

FACEPLATE<br />

LED<br />

WATTAGE<br />

LED<br />

SELECTION VOLTAGE FINISH OPTIONS<br />

Enter the order code into the appropriate box above. Omit WALL TYPE for 943L-B25 and 943L-B40. Note: Philips Gardco reserves the right to refuse a configuration. Not all<br />

combinations and configurations are valid. Refer to notes below for exclusions and limitations. For questions or concerns, please consult the factory.<br />

PREFIX<br />

Complete Luminaires<br />

941L 1 Horizontal<br />

942L Horizontal<br />

943 L Vertical<br />

943L-B25 943L Mounted in 25" Bollard<br />

943L-B40 943L Mounted in 40" Bollard<br />

Retrofit Kits 1<br />

RK-941L 1,2 Horizontal<br />

RK-942L 2 Horizontal<br />

RK-943L 2 Vertical<br />

LED WATTAGE with LUMEN DATA<br />

WALL TYPE<br />

D Drywall<br />

Not suitable for concrete pour applications. Also,<br />

if insulating material is present, it must be kept<br />

at least 3" away from luminaire. Type D units are<br />

thermally protected. Non-IC luminaire.<br />

C Concrete Pour<br />

Suitable for concrete pour applications only.<br />

NOTE: WALL TYPE does not apply to<br />

943L-B25 and 943L-B40. Omit WALL TYPE for<br />

943L-B25 and 943L-B40.<br />

FACEPLATES<br />

LV Louver<br />

DG 1 Diffuse Glass<br />

RGD 1 Ribbed Guard with Diffuse Glass<br />

1. 941L and RK-941L are not available with the RGD faceplate.<br />

2. Retrofit kits are available in Wall Type “C” only (Concrete Pour.) Retrofit<br />

kits are not available for existing Wall Type “D” (Drywall) luminaires. The<br />

step light portion of existing 943BL25 and 943BL40 units may be<br />

replaced utilizing RK-943L retrofit kits.<br />

Back housings for concrete pour applications (Type C) are available for<br />

pre-shipment. Contact factory for details.<br />

Order<br />

Code<br />

Description<br />

LED<br />

Current<br />

(mA)<br />

Average<br />

<strong>System</strong><br />

Watts 3<br />

LED<br />

Selection<br />

Absolute Initial Luminaire Lumens 4<br />

941 942 943<br />

Faceplate Faceplate Faceplate<br />

LV DG LV DG RGD LV DG RGD<br />

20LA<br />

20 watt,<br />

LED integral lens array.<br />

350 20<br />

CW 64 (s) 564 (s) 124 (s) 652 (s) 220 (s) 123 (s) 596 (s) 222 (s)<br />

NW 60 538 118 621 209 117 568 (s) 211 (s)<br />

31LA<br />

31 watt,<br />

LED integral lens array.<br />

530 31<br />

CW 90 (s) 749 (s) 167 (s) 838 (s) 306 (s) 169 (s) 808 (s) 301 (s)<br />

NW 85 713 159 798 292 161 770 (s) 286 (s)<br />

40LA 5<br />

40 watt,<br />

LED integral lens array.<br />

700 40<br />

CW See Note 5 See Note 5 221 1132 407 207 (s) 1010 (s) 376 (s)<br />

NW See Note 5 See Note 5 191 1063 357 197 962 358<br />

3. <strong>System</strong> input wattage may vary based on input voltage, by up to +/- 10% , and based on manufacturer forward voltage, by up to +/- 8%.<br />

4. Lumen values based on photometric tests performed in compliance with IESNA LM-79. Values are for luminaires with a white faceplate. Values will vary based on faceplate color chosen.<br />

Contact Gardco.Applications@philips.com for values not shown above.<br />

5. 941L is not available in 40LA (700mA) LED wattage. Lumen values shown are based on Bronze painted faceplates. Values will vary based on the faceplate color.<br />

(s) indicates values are scaled value based on tests of similar, but not identical, luminaire configurations.<br />

(UO) 1611 Clovis Straub Barker Hall Road, - Deferred San Marcos, Maintenance<br />

TX 78666<br />

Type (800) 227-0758 SB (512) 753-1000 FAX: (512) 753-7855 sitelighting.com<br />

Gardco: © 2012 Koninklijke 941L-20LA-C-DG-NW-UNVI-BRP<br />

Philips Electronics N.V. All Rights Reserved.<br />

Philips Gardco reserves the right to change materials or modify the design of its product without<br />

Northern Illumination Company<br />

notification as part of the company’s continuing product improvement program.<br />

G200-040/1212


Page 2 of 3<br />

LED SELECTION<br />

CW<br />

NW<br />

WW<br />

AM<br />

5,700°K , 75CRI<br />

4,000°K , 70CRI<br />

3,000°K , 80CRI<br />

Amber<br />

VOLTAGE<br />

120 6<br />

277 6<br />

UNIV 7<br />

6. Wall Type D luminaires only.<br />

7. UNIV means120V through 277V<br />

input. Not available on<br />

Wall Type D luminaires.<br />

94 Line LED<br />

941L, 942L and 943L Step and Aisle Lights<br />

FINISH<br />

BLP Black Paint<br />

BRP Bronze Paint<br />

WP White Paint<br />

NP Natural Aluminum Paint<br />

OC<br />

SC<br />

TYPE SB<br />

Optional Color Paint<br />

(Specify RAL designation. ex: OC-RAL7024)<br />

Special Color Paint<br />

(Specify. Must supply color chip)<br />

OPTIONS<br />

F<br />

TP Tamper Resistant Screws<br />

SPR 8 Surge Protection -<br />

120V through 277V -<br />

meeting ANSI C62.41.2<br />

Fusing (Provide specific input voltage.)<br />

8. Not available with Fusing (F) option.<br />

DIMENSIONS<br />

941L Dimensions<br />

12.00"<br />

30.48 12" cm<br />

3.25"<br />

8.26 3.25" cm<br />

(DG) Diffuse Glass<br />

6.75"<br />

17.15 6.75" cm<br />

3.50" 3.5"<br />

8.89 cm<br />

(LV) Louver<br />

2.75"<br />

6.99<br />

2.75"<br />

cm<br />

6.00"<br />

15.24 cm 6"<br />

942L Dimensions<br />

943L Dimensions<br />

13"<br />

(33 cm)<br />

8.5" (21.6 cm)<br />

5.5"(14 cm)<br />

5.5"(14 cm)<br />

5.5"<br />

(14 cm)<br />

5.5"<br />

(14 cm)<br />

13"<br />

(33 cm)<br />

15.8" (40.1 cm)<br />

40.1"<br />

(101.7 cm)<br />

24.6"<br />

(62.5 cm)<br />

8.5" (21.6 cm)<br />

5.5" (14 cm)<br />

5"<br />

(12.7cm)<br />

8" (20.3 cm)<br />

8.5"<br />

(21.6 cm)<br />

943L-B40<br />

8.5"<br />

(21.6 cm)<br />

943L-B25<br />

1611 Clovis Barker Road, San Marcos, TX 78666<br />

(800) 227-0758 (512) 753-1000 FAX: (512) 753-7855 sitelighting.com<br />

(UO) © 2012 Straub Koninklijke Hall Philips - Deferred Electronics N.V. Maintenance<br />

All Rights Reserved.<br />

Type Philips Gardco SB reserves the right to change materials or modify the design of its product without<br />

Gardco: notification 941L-20LA-C-DG-NW-UNVI-BRP<br />

as part of the company’s continuing product improvement program.<br />

Northern G200-040/1212 Illumination Company


Page 3 of 3<br />

SPECIFICATIONS<br />

TYPE SB<br />

GENERAL: The Philips Gardco 941L, 942L and 943L recessed aisle lights are<br />

architecturally styled luminaires precisely constructed of die cast aluminum,<br />

providing light with high performance, long life LED systems. A field adjustable<br />

junction box enhances design flexibility. Self-compensating silicone gasketing<br />

completely excludes moisture, insects and contaminants. A choice of three<br />

(3) architecturally designed faceplates allows for a variety of applications. The<br />

ribbed guard faceplate offers vandal protection for glass lenses.<br />

RETROFIT KITS: Retrofit kits are also available, making it possible to update<br />

installations of classic 941, 942 and 943 Philips Gardco fluorescent and HID step<br />

lights to LED without the need to replace the back housing. Retrofit kits are<br />

available in Wall Type “C” only (Concrete Pour.) Retrofit kits are not available<br />

for existing Wall Type “D” (Drywall) luminaires. The step light portion of<br />

existing 943BL25 and 943BL40 units may be replaced utilizing RK-943L retrofit<br />

kits.<br />

FACEPLATE: All faceplates are constructed of one piece die cast aluminum<br />

and are secured to the housing with two (2) recessed and captive hex<br />

head socket screws. Integral spring clips ensure positive grounding. Selfcompensating<br />

single-piece silicone gasketing completely seals the luminaire and<br />

allows for varying wall thicknesses.<br />

94 Line LED<br />

941L, 942L and 943L Step and Aisle Lights<br />

THERMAL MANAGEMENT: Philips Gardco 94 Line LED step and aisle<br />

lights include integral thermal control to provide the excellent thermal<br />

management so critical to long LED system life.<br />

Electrical: Luminaires are equipped with an LED driver that accepts 120V<br />

through 277V, 50hz to 60hz, input (Wall Type C) , or with specific 120V or<br />

277V input voltages (Wall Type D). Driver output is based on the LED wattage<br />

selected. Component-to-component wiring within the luminaire will carry no<br />

more than 80% of rated current and is listed by UL for use at 600 VAC at 302°F<br />

/ 150°C or higher. Plug disconnects are listed by UL for use at 600 VAC, 15A or<br />

higher. Power factor is not less than 90%. Luminaire consumes 0.0 watts in the<br />

off state.<br />

FINISH: Each standard color luminaire receives a fade and abrasion resistant,<br />

electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC)<br />

textured polyester powdercoat finish. Standard colors include bronze (BRP),<br />

black (BLP), white (WP), and natural aluminum (NP). Consult factory for specs<br />

on optional or custom colors.<br />

LABELS: All luminaires bear UL or CUL (where applicable) Wet Location<br />

labels.<br />

LOUVER: Die cast louvers span the entire length of the faceplate, providing<br />

for vandal resistance and glare control. Louver faceplate include diffuse glass<br />

behind the louvers to minimize apparent glare from the luminaire.<br />

DIFFUSE GLASS: The faceplate includes a 3/16" thick diffuse white opal flat<br />

tempered glass lens. The lens is internally sealed and mounted and provides a<br />

soft, uniform glow.<br />

WARRANTY: Philips Gardco luminaires feature a 5 year limited warranty.<br />

Philips Gardco LED luminaires feature a 5 year limited warranty covering the<br />

LED arrays and LED drivers. See Warranty Information on www.sitelighting.com<br />

for complete details and exclusions.<br />

RIBBED GUARD: 90° die cast louvers span the entire length of the faceplate<br />

over a diffuse glass lens. Not available in the 941L and RK-941L.<br />

HOUSING: The housing is corrosion-resistant die cast aluminum.<br />

J-BOX: The field convertible junction box is die cast aluminum. It is shipped<br />

factory-mounted to the back of housing. The box can be easily positioned<br />

on the bottom of the luminaire via two (2) phillips head screws. Each J-box<br />

includes three (3) threaded openings (one on each side and one on the bottom)<br />

that accommodate 3/4” conduit.<br />

LED RELIABILITY:<br />

PREDICTED LUMEN DEPRECIATION DATA<br />

Ambient Temperature °C Driver mA L 70 Hours 9<br />

25 °C<br />

40 °C<br />

350 mA 180,000<br />

530 mA 115,000<br />

700 mA 95,000<br />

350 mA 175,000<br />

530 mA 100,000<br />

700 mA 90,000<br />

9 Predicted performance derived from LED manufacturer’s data and engineering design estimates,<br />

based on IESNA LM-80 methodology. Actual experience may vary due to eld application<br />

conditions. L 70 is the predicted time when LED performance depreciates to 70% of initial<br />

lumen output.<br />

1611 Clovis Barker Road, San Marcos, TX 78666<br />

(UO) Straub Hall - Deferred Maintenance<br />

(800) 227-0758 (512) 753-1000 FAX: (512) 753-7855 sitelighting.com<br />

Type SB<br />

© 2012 Koninklijke Philips Electronics N.V. All Rights Reserved.<br />

Gardco: 941L-20LA-C-DG-NW-UNVI-BRP<br />

Philips Gardco reserves the right to change materials or modify the design of its product without<br />

Northern Illumination Company<br />

notification as part of the company’s continuing product improvement program.<br />

G200-040/1212


SUBSTITUTION REQUEST<br />

TO: Rowell Brokaw Architects<br />

PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />

SPECIFIED ITEM: Bartco, IPR8MS Series<br />

Section 26500 Type: V1<br />

PROPOSED SUBSTITUTION: Metalumen, RM4D-2-T8-4-OL-S-X-E-1-277-N<br />

Attached data includes product description, specifications, drawings, photographs, performance and test<br />

data adequate for evaluation of request including identification of applicable data portions.<br />

Attached data also includes description of changes to Contract Documents and proposed substitution<br />

requires for proper installation.<br />

Undersigned certifies following items, unless modified by attachments, are correct:<br />

1. Proposed substitution does not affect dimensions shown on drawings.<br />

2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />

construction costs caused by proposed substitution.<br />

3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />

requirements.<br />

4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />

Undersigned further certifies function, appearance, and quality of proposed substitution<br />

are equivalent or superior to specified item.<br />

Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />

found in Bidding Documents apply to this proposed substitution.<br />

Submitted by:<br />

Name (Printed or typed)<br />

David Wray<br />

General Contractor (if after award of Contract)<br />

For use by A/E<br />

Signature<br />

Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />

Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />

City, State, Zip: Portland, OR 97224<br />

Date: 5/7/13<br />

By Jesse Smith - Glumac Lighting Studio<br />

Date 5/20/2013<br />

Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks Fixture must have wrap lens<br />

The Construction Specifications Institute September 1997<br />

Northwest Region


TYPE V1<br />

Ordering Guide<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

106 [4.2]<br />

102 [4.0]<br />

119 [4.7]<br />

119 [4.7]<br />

102 [4.0]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Part number example<br />

91 [3.6]<br />

115 [4.5]<br />

91 [3.6]<br />

120 [4.7]<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant Recessed Drywall Recessed T-bar Surface Wall<br />

91 [3.6]<br />

95 [3.7]<br />

Dimensions and photometry see reverse.<br />

RM4D 2S T5 12 N SL RD A E 1 347 N<br />

Model<br />

RM4D<br />

Number of<br />

Lamps<br />

Lamp<br />

Type<br />

Length<br />

Control<br />

Up<br />

N<br />

Control<br />

Down<br />

Mounting<br />

Finish<br />

Ballast<br />

Driver<br />

Circuitry Voltage Options<br />

No. of Lamps Length Control Up<br />

1<br />

1 Lamp<br />

1S<br />

1<br />

Staggered*<br />

1L<br />

1 LED<br />

2<br />

2 Lamps*<br />

2S<br />

2<br />

Staggered*<br />

*(T8 with opal<br />

satin lens<br />

only)<br />

Lamp Type<br />

4<br />

4 Foot<br />

8<br />

8 Foot<br />

12<br />

12 Foot<br />

R<br />

Continuous<br />

Length<br />

(consult<br />

factory)<br />

(fixtures<br />

supplied in<br />

nominal 1’<br />

increments only)<br />

T8 32W<br />

T5 28W<br />

T5HO 54W<br />

LED30K* 3000k<br />

LED35K* 3500k<br />

LED40K* 4000k<br />

*available with opal satin lens only<br />

N<br />

None<br />

Control<br />

Down<br />

SL<br />

Specular<br />

Parabolic<br />

Louver<br />

SSL<br />

Semi<br />

Specular<br />

Parabolic<br />

Louver<br />

OL<br />

Opal Satin<br />

Lens<br />

A<br />

Asymmetrical<br />

reflector<br />

(single T5,<br />

T5HO, T8 only)<br />

Mounting Ballast Circuitry Voltage Options<br />

Pendant<br />

Y<br />

Yoke Aircraft<br />

Cable<br />

RT<br />

Recessed<br />

T-Bar<br />

RD<br />

Recessed<br />

Drywall<br />

S<br />

Surface<br />

W<br />

Wall<br />

Finish<br />

A<br />

Anodized<br />

Aluminum<br />

C<br />

Custom<br />

For custom<br />

Finish specify<br />

RAL#<br />

Standard<br />

E<br />

Electronic Instant Start T8<br />

Programmed Rapid Start -T5/T5HO<br />

Dimming 120V/277V Dimming<br />

D1 Advance Mark 7<br />

(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />

D2 Advance Mark 10<br />

(1/2 Lamp T8, 1/2 Lamp T5HO)<br />

D4 Lutron Hi-lume<br />

(1/2 Lamp T8, T5HO)<br />

D5 Lutron Eco-<strong>System</strong><br />

(T5-T5HO-T8) (347V available)<br />

(some lamp/ballast cominations may<br />

not be available — consult factory for<br />

availability)<br />

Battery Pack Options<br />

BN1 Bodine B50LP (T8)<br />

BN2 Bodine LP400 (T8)<br />

BN3 Bodine LP500 (T5)<br />

BN4 Bodine LP600 (T5/T5HO/T8)<br />

1<br />

1 Circuit<br />

(Standard)<br />

AB*<br />

Alternating<br />

Switching<br />

EN*<br />

Emergency/<br />

Night Light<br />

LED Driver<br />

/LR*<br />

Left-right<br />

Switching<br />

*n/a for LED<br />

120<br />

277<br />

347*<br />

*(not<br />

available<br />

for LED)<br />

N<br />

None<br />

D<br />

Daylight<br />

Sensor<br />

O<br />

Occupancy<br />

Sensor<br />

DOS<br />

Daylight/<br />

Occupancy<br />

Sensor<br />

Maximum fixture lumens/foot<br />

Standard Dimming 3000k 3500k 4000k<br />

S350 (350mA) D350 (350mA) 480 510 533<br />

S700 (700mA) D700 (700mA) 959 1019 1065<br />

Approvals<br />

R1-07-12<br />

570 Southgate Drive, Guelph, Ontario N1G 4P6<br />

Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />

T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />

www.metalumen.com<br />

(UO) Signature Straub Hall - Deferred Maintenance<br />

Type V1<br />

Metalumen: RM4D-2-T8-4-OL-S-X-E-1-277-N<br />

Northern Date Illumination Company<br />

1


TYPE V1<br />

Ordering Guide<br />

SPECIFICATIONS<br />

T8, T5, T5H0<br />

Grande RM4D<br />

Series<br />

DIRECT – Pendant, Recessed, Surface, Wall<br />

TAB<br />

15<br />

CONSTRUCTION SPECIFICATIONS<br />

HOUSING<br />

Rigid extruded aluminum body, 2.0mm [0.08”]<br />

nominal wall thickness. 95mm [3.7”] width x 102mm<br />

[4.0”] high (Pendant/Wall/Surface)<br />

115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />

End Caps: C.R.S.<br />

FINISH<br />

Anodized aluminum, Custom finishes available.<br />

T8, T5, T5HO<br />

102 [4.0]<br />

LED<br />

102 [4.0]<br />

LIGHTING CONTROL OPTIONS<br />

Specular or semi specular parabolic louvre<br />

High transmittance snap in satin lens<br />

Asymmetrical reflector — single lamp only — open<br />

bottom<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

91 [3.6]<br />

95 [3.7]<br />

Pendant<br />

MOUNTING<br />

PENDANT<br />

Steel aircraft cable yoke complete with a Quick-Grip<br />

field adjustable suspension system provides for quick<br />

and easy onsite alignment.<br />

119 [4.7]<br />

119 [4.7]<br />

RECESSED<br />

T-Bar — Mounting clips supplied<br />

Drywall — Mounting brackets supplied<br />

WALL<br />

Wall brackets supplied<br />

SURFACE<br />

Direct to surface mount<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

91 [3.6]<br />

115 [4.5]<br />

Recessed Drywall<br />

LED/DRIVER SPECIFICATIONS<br />

Medium power LED’s<br />

Color temperatures available: 3000K, 3500K, 4000K<br />

CRI: 84 (4000K) (80 minimum)<br />

Nominal power consumption: 15W - 700mA, 7.5W -<br />

350mA<br />

Hours: 50,000<br />

Maximum delivered lumens/foot:<br />

350mA<br />

3000K 480 lm/ft<br />

3500K 510 lm/ft<br />

4000K 533 lm/ft<br />

700mA<br />

3000K 959 lm/ft<br />

3500K 1019 lm/ft<br />

4000K 1065 lm/ft<br />

Voltage: 120V or 277V input voltage.<br />

Heat Sink: Extruded Aluminum Profile<br />

LED connections: Board mounted connectors.<br />

Drivers: available from several manufacturers.<br />

Drivers matched to run lengths and specific LED light<br />

engines.<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

119 [4.7]<br />

91 [3.6]<br />

120 [4.7]<br />

Recessed T-bar<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

Surface<br />

106 [4.2]<br />

Certification<br />

Testing Standards: Tested in accordance with IESL-<br />

M79-08<br />

RoHS Compliant<br />

Warranty: 3 year<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

102 [4.0]<br />

91 [3.6]<br />

95 [3.7]<br />

(UO) Straub Hall - Deferred Maintenance<br />

Type V1<br />

Metalumen: RM4D-2-T8-4-OL-S-X-E-1-277-N<br />

Northern Illumination Company<br />

2<br />

Wall<br />

Wall<br />

R1-07-12


Jesse Smith - Glumac Lighting Studio<br />

5/20/2013<br />

Please provide a sample<br />

of this fixture series.


Jesse Smith - Glumac Lighting Studio<br />

5/20/2013<br />

Please provide a sample<br />

of this fixture series.


Jesse Smith - Glumac Lighting Studio<br />

5/20/2013<br />

Please provide a sample<br />

of this fixture series.


Jesse Smith - Glumac Lighting Studio<br />

5/20/2013


Jesse Smith - Glumac Lighting Studio<br />

5/20/2013<br />

Please provide a sample<br />

of this fixture series.


Straub Hall Window Condition Assessment<br />

May 2011<br />

<strong>University</strong> of <strong>Oregon</strong><br />

Campus Planning & Real Estate


Project Contacts<br />

Liz Carter, Student<br />

Christine Taylor Thompson, Planning Associate<br />

<strong>University</strong> of <strong>Oregon</strong><br />

Campus Planning and Real Estate<br />

1276 <strong>University</strong> of <strong>Oregon</strong><br />

Eugene, <strong>Oregon</strong> 97403-1276<br />

http://uplan.uoregon.edu<br />

(541) 346-5562<br />

Additional information about the history of Straub Hall and campus development is<br />

available on the CPRE website: http://uplan.uoregon.edu/. follow the link to “Planning<br />

documents” and then “Historic Preservation” to find the UO 4.0 Survey of Buildings and the<br />

Heritage Landscape Plan.<br />

Special thank you to Straub Hall Building manager, George Helbling.<br />

Straub Hall Window Condition Assessment - 1


Purpose of Assessment:<br />

Straub Hall was designed in the Colonial Revival style as a men’s dormitory and constructed in 1928-29. The building continued to serve as a<br />

dormitory until 1971 when the process to convert the building for academic purposes was started.<br />

Straub Hall will soon undergo an extensive remodel. Identified as a Deferred Maintenance Project, the Project will implement seismic<br />

upgrades; retrofit or replace existing heating, ventilation, electrical, plumbing, and lighting systems with more energy and water efficient<br />

systems; enhance the thermal performance of the building envelope; and improve accessibility. The purpose of this survey is to assist the<br />

project by assessing the condition of the exterior windows to provide information for decision making associated with window enhancement,<br />

replacement, and/or restoration.<br />

Scope of Assessment:<br />

This survey will be looking at all exterior windows in Straub Hall, including skylights and foundation/basement windows. The scale of<br />

Condition used for this survey is as follows:<br />

EXCELLENT = only superficial damage (like chipping paint)<br />

GOOD = will require some invasive repair to parts but can be restored<br />

FAIR = will require extensive invasive repair to parts to be restored<br />

POOR = window parts are unsalvagable.<br />

Findings of Assessment:<br />

Overall, the assessed Straub Hall windows are in GOOD condition. Most of the damage to the windows is superficial. Areas most affected<br />

are the brick sills and the exterior wood sill/casings’ paint. In areas that have been without proper paint coverage (mainly the south and west<br />

facades), checking of the wood sills has occurred.<br />

General Notes:<br />

Unless otherwise noted all window parts and hardware appear to be original. Most windows in the building, excluding select few that<br />

correspond with staircases or the like, have be designed to be operable. Some of these windows have since become inoperable for various<br />

reasons. Some of these windows are currently considered inoperable but only need new weight cords to be operable. The majority of the<br />

windows on the first, second, and third floors are double hung with wood muntins. The basement windows are mostly double casement<br />

windows or double hung, both with wood muntins. There are four windows that are double height. These are in the staircases stretching<br />

between the third and fourth floors.<br />

Straub Hall Window Condition Assessment - 2


STRAUB WINDOW CONDITION ASSESSMENT<br />

Window Parts Key: J = Jamb, IC = Interior Casing, RS = Rail and Stiles, St = Stool<br />

Indicates that there is a current issue with the window impeding its function<br />

* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

024a<br />

025a<br />

028a<br />

028b<br />

028c<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top<br />

double hung<br />

clearstory,<br />

w/wood<br />

muntins<br />

aluminium<br />

slider<br />

clearstories<br />

aluminium<br />

slider<br />

clearstories<br />

aluminium<br />

slider<br />

clearstories<br />

Conditions<br />

Window<br />

Paint<br />

Parts*<br />

excellent excellent NA excellent poor, right<br />

weight cord<br />

broken<br />

Brick Sill<br />

Facing<br />

Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

no good north<br />

fair excellent NA excellent no, painted<br />

into place<br />

excellent excellent excellent,<br />

concrete sill<br />

excellent excellent excellent,<br />

concrete sill<br />

excellent excellent excellent,<br />

concrete sill<br />

030Aa casement good poor, only<br />

casing<br />

remains<br />

no good north<br />

excellent excellent no excellent south yes<br />

excellent excellent no excellent south<br />

excellent excellent no excellent south<br />

NA NA open to<br />

foundations<br />

no<br />

good, but north<br />

no longer<br />

connects to<br />

outdoors<br />

window is now an open<br />

connection to<br />

foundation<br />

yes<br />

030Ab casement good, some<br />

chipping<br />

good NA excellent yes, opens to<br />

foundations<br />

no<br />

good, but north<br />

no longer<br />

connects to<br />

outdoors<br />

window is now a<br />

closable connection to<br />

foundation<br />

yes<br />

Straub Hall Window Condition Assessment - 3


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

051a<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

Conditions<br />

Window<br />

Paint<br />

Parts*<br />

good excellent moss and<br />

debris covered<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

fair, chipped poor, right<br />

but weight cord<br />

functional broken<br />

Facing<br />

Elev. Comments Photo<br />

no fair south only one window is<br />

noted on plans, while<br />

there are two windows<br />

in this room<br />

051b<br />

double hung good<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

large gouges<br />

in top sash<br />

moss and<br />

debris covered<br />

excellent<br />

poor, left<br />

weight cord<br />

broken<br />

no fair south only one window is<br />

noted on plans, while<br />

there are two windows<br />

in this room<br />

Straub Hall Window Condition Assessment - 4


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

105a<br />

109a<br />

109b<br />

109c<br />

109d<br />

109e<br />

double hung,<br />

lower<br />

portion<br />

operable,<br />

with wood<br />

muntins<br />

double hung,<br />

lower<br />

portion<br />

operable,<br />

with wood<br />

muntins<br />

double hung,<br />

lower<br />

portion<br />

operable,<br />

with wood<br />

muntins<br />

double hung,<br />

lower<br />

portion<br />

operable,<br />

with wood<br />

muntins<br />

double hung,<br />

lower<br />

portion<br />

operable,<br />

with wood<br />

muntins<br />

double hung,<br />

lower<br />

portion<br />

operable,<br />

with wood<br />

muntins<br />

Conditions<br />

Paint<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent excellent excellent, yes no excellent south opens into courtyard yes<br />

modified<br />

excellent excellent excellent excellent,<br />

modified<br />

with<br />

secondary<br />

locks<br />

excellent excellent excellent excellent,<br />

modified<br />

with<br />

secondary<br />

locks<br />

excellent excellent excellent excellent,<br />

modified<br />

with<br />

secondary<br />

locks<br />

excellent excellent excellent excellent,<br />

modified<br />

with<br />

secondary<br />

locks<br />

excellent excellent excellent modified<br />

with<br />

secondary<br />

locks,<br />

broken left<br />

weight cord<br />

poor, right<br />

weight cord<br />

broken<br />

no, painted<br />

into place<br />

no, painted<br />

into place<br />

poor, broken<br />

left weight<br />

cord<br />

no excellent east windows new (2001),<br />

they do not open<br />

windows in this room<br />

to control humidity, due<br />

to its proximity to the<br />

MRI.<br />

no excellent east<br />

no excellent east<br />

no excellent north<br />

poor no excellent north<br />

Straub Hall Window Condition Assessment - 5


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

111a<br />

111b<br />

113a<br />

S113a<br />

119a<br />

119b<br />

double hung,<br />

lower<br />

portion<br />

operable.<br />

with wood<br />

muntins<br />

double hung,<br />

lower<br />

portion<br />

operable,<br />

with wood<br />

muntins<br />

double hung,<br />

lower<br />

portion<br />

operable,<br />

with wood<br />

muntins<br />

double hung,<br />

lower<br />

portion<br />

operable,<br />

with wood<br />

muntins<br />

double hung,<br />

lower<br />

portion<br />

operable,<br />

with wood<br />

muntins<br />

double hung,<br />

lower<br />

portion<br />

operable<br />

with wood<br />

muntins<br />

Conditions<br />

Paint<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent excellent modified poor no good north<br />

with<br />

secondary<br />

locks,<br />

broken left<br />

weight cord<br />

excellent excellent excellent excellent, poor, sticky no good north window not on current<br />

modified<br />

drawings<br />

with<br />

secondary<br />

locks<br />

excellent excellent excellent excellent,<br />

modified<br />

with<br />

secondary<br />

locks<br />

excellent excellent excellent none no, not an<br />

operable<br />

window<br />

excellent excellent excellent excellent,<br />

modified<br />

with<br />

secondary<br />

locks<br />

excellent excellent excellent excellent,<br />

modified<br />

with<br />

secondary<br />

locks<br />

yes no excellent north<br />

no excellent south opens into courtyard<br />

yes no excellent south<br />

yes no excellent north<br />

Straub Hall Window Condition Assessment - 6


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

119c<br />

S120a<br />

double hung,<br />

lower<br />

portion<br />

operable<br />

with wood<br />

muntins<br />

fixed wood<br />

window with<br />

muntins<br />

Conditions<br />

Paint<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent excellent excellent, yes no excellent north<br />

modified<br />

with<br />

secondary<br />

locks<br />

excellent excellent excellent none no no excellent east window not on current<br />

plan<br />

122a<br />

double hung excellent excellent good, some<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

moss<br />

accumulation<br />

fair, chipped<br />

but<br />

functional<br />

top window<br />

has been<br />

fixed<br />

no excellent north<br />

122b<br />

double hung excellent excellent good, some<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

moss<br />

accumulation<br />

excellent yes no excellent north<br />

122c<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

excellent excellent excellent excellent top window<br />

has been<br />

fixed<br />

no excellent north<br />

122d<br />

double hung excellent excellent good, some<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

moss<br />

accumulation<br />

fair, chipped<br />

but<br />

functional<br />

yes no excellent west<br />

Straub Hall Window Condition Assessment - 7


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

126a<br />

127a<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

bottom<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

Conditions<br />

Window<br />

Paint<br />

Parts*<br />

excellent excellent excellent fair, chipped<br />

but<br />

functional<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

no longer no excellent,<br />

operable,<br />

but altered<br />

window has<br />

been fixed in<br />

place and<br />

one of the<br />

top panes fit<br />

with a fan<br />

excellent excellent excellent excellent excellent no excellent west<br />

Facing<br />

Elev. Comments Photo<br />

east window diffuse glass, yes<br />

lower one painted<br />

white.<br />

128a<br />

129a<br />

130a<br />

S130a<br />

double hung excellent excellent excellent excellent excellent no excellent east<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

double hung excellent excellent excellent excellent excellent no excellent west Screen on exterior,<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

lower window does not<br />

remain open on its own.<br />

double hung excellent excellent excellent excellent excellent no excellent east has weight cord<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

protectors.<br />

fixed wood excellent excellent excellent none no no excellent east<br />

window with<br />

muntins<br />

Straub Hall Window Condition Assessment - 8


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

131a<br />

131b<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

Conditions<br />

Paint<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

excellent excellent excellent excellent excellent no excellent west With exterior screen.<br />

May had been top<br />

opening as well and<br />

painted in place.<br />

excellent excellent excellent excellent poor, right<br />

weight cord<br />

broken<br />

no excellent west<br />

Facing<br />

Elev. Comments Photo<br />

137a<br />

double hung flaking on<br />

w/wood muntins<br />

muntins,<br />

opening from<br />

top & bottom<br />

excellent<br />

good, some<br />

moss<br />

accumulation<br />

good, has<br />

been<br />

modified<br />

with an<br />

additional<br />

sling lock on<br />

bottom sash<br />

excellent no good west signs of past<br />

condensation<br />

accumulation on<br />

muntins<br />

139a<br />

139b<br />

double hung fair, flaking on good<br />

w/wood sill and outer<br />

muntins, casing<br />

opening from<br />

bottom<br />

double hung fair, extensive good<br />

w/wood flaking on sill<br />

muntins, and outer casing<br />

opening from<br />

bottom<br />

good moss<br />

accumulation<br />

good moss<br />

accumulation<br />

good, lock yes no good west yes<br />

and pulls are<br />

intact<br />

good, lock yes no good west yes<br />

and pulls are<br />

intact<br />

Straub Hall Window Condition Assessment - 9


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

140a<br />

141a<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

bottom<br />

Conditions<br />

Window<br />

Paint<br />

Parts*<br />

excellent excellent excellent fair, initial<br />

lock no<br />

longer<br />

functions,<br />

but is still in<br />

place, a new<br />

lock placed<br />

nest to old<br />

one<br />

double hung good excellent good, some<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

moss<br />

accumulation<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

fair, chipped<br />

but<br />

functional<br />

Facing<br />

Elev. Comments Photo<br />

yes no excellent north modified with various<br />

types of diffuse glass<br />

poor, right<br />

weight cord<br />

broken, top<br />

fixed in place<br />

with paint<br />

no fair west<br />

142a<br />

142b<br />

fixed wood<br />

window<br />

w/muntins<br />

over a<br />

double hung<br />

w/wood<br />

muntins<br />

which is<br />

operable<br />

from top &<br />

bottom<br />

fixed wood<br />

window<br />

w/muntins<br />

over a<br />

double hung<br />

w/wood<br />

muntins<br />

which is<br />

operable<br />

from top &<br />

bottom<br />

excellent excellent good, large<br />

amount of<br />

moss<br />

accumulation<br />

excellent excellent good, large<br />

amount of<br />

moss<br />

accumulation<br />

excellent<br />

excellent<br />

poor, top<br />

window<br />

stuck in<br />

place, lower<br />

window<br />

operable<br />

poor, top<br />

window<br />

stuck in<br />

place, lower<br />

window<br />

operable<br />

no excellent north opens into courtyard yes<br />

no excellent north opens into courtyard<br />

Straub Hall Window Condition Assessment - 10


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

142c<br />

transome<br />

window,<br />

fixed wood<br />

window with<br />

muntins<br />

Conditions<br />

Window<br />

Paint<br />

Parts*<br />

excellent excellent excellent, wood<br />

sill<br />

Brick Sill<br />

Facing<br />

Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

none no no excellent north opens into courtyard<br />

142d<br />

146a<br />

146a<br />

fixed wood<br />

window<br />

w/muntins<br />

over a<br />

double hung<br />

w/wood<br />

muntins<br />

which is<br />

operable<br />

from top &<br />

bottom<br />

gable end<br />

clearstories,<br />

w/wood<br />

muntins and<br />

mullions<br />

gable end<br />

clearstories,<br />

w/wood<br />

muntins and<br />

mullions<br />

excellent excellent good, large<br />

amount of<br />

moss<br />

accumulation<br />

excellent excellent unable to<br />

evaluate due to<br />

height<br />

excellent<br />

appears to<br />

be in<br />

excellent<br />

condition<br />

excellent excellent unable to appears to<br />

evaluate due to be in<br />

height excellent<br />

condition<br />

poor, top<br />

window<br />

stuck in<br />

place, lower<br />

window<br />

operable<br />

yes, the<br />

windows on<br />

either end<br />

appear to be<br />

operable,<br />

due to the<br />

presence of<br />

hardware<br />

yes, the<br />

windows on<br />

either end<br />

appear to be<br />

operable,<br />

due to the<br />

presence of<br />

hardware<br />

no excellent north opens into courtyard<br />

no excellent north Assessment was made<br />

from ground level,<br />

window height ~ 12'<br />

no excellent north Assessment was made<br />

from ground level,<br />

window height ~ 12'<br />

yes<br />

Straub Hall Window Condition Assessment - 11


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

L150a arched<br />

transoms,<br />

w/wood<br />

mullions &<br />

muntins<br />

Paint<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent good, heat lock and no no excellent east Does the lock and chain yes<br />

damage chain<br />

suggest that these<br />

attached in<br />

windows were operable<br />

Lobby<br />

before the connecting<br />

interior<br />

coridoor was installed<br />

L150b<br />

L150c<br />

L150d<br />

L150e<br />

L150f<br />

152Aa<br />

arched<br />

transoms,<br />

w/wood<br />

mullions &<br />

muntins<br />

arched<br />

transoms,<br />

w/wood<br />

mullions &<br />

muntins<br />

arched<br />

transoms,<br />

w/wood<br />

mullions &<br />

muntins<br />

arched<br />

transoms,<br />

w/wood<br />

mullions &<br />

muntins<br />

arched<br />

transoms,<br />

w/wood<br />

mullions &<br />

muntins<br />

excellent excellent good, heat<br />

damage<br />

excellent excellent good, heat<br />

damage<br />

no no excellent east interior yes<br />

no no excellent east interior yes<br />

excellent excellent excellent, wood none no no excellent west yes<br />

sill<br />

excellent excellent excellent, wood none no no excellent west<br />

sill<br />

excellent excellent excellent, wood none no no excellent west<br />

sill<br />

double hung excellent excellent excellent excellent yes no excellent west diffuse glazing<br />

w/wood<br />

muntins,<br />

opening from<br />

bottom<br />

Straub Hall Window Condition Assessment - 12


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

152Ba<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

Paint<br />

deeply flaked<br />

sill and lower<br />

exterior casing<br />

Window<br />

Parts*<br />

excellent<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

major moss excellent yes no fair south major moss<br />

yes<br />

accumulation<br />

accumulation, sill sits<br />

~1" above ground level<br />

153a<br />

154a<br />

double hung<br />

w/wood<br />

muntins<br />

excellent excellent major moss<br />

accumulation<br />

double hung excellent, some<br />

w/wood chipping on<br />

muntins and exterior<br />

a fixed upper<br />

excellent good, minor<br />

with exterior moss<br />

wood framed accumulation<br />

screen<br />

excellent no no excellent west this window has been<br />

sheetrocked over from<br />

the interior, it is located<br />

in the women's<br />

bathroom. Assessment<br />

made from exterior.<br />

excellent not no excellent south yes<br />

accessible<br />

155a<br />

155b<br />

double hung good, some<br />

w/wood chipping<br />

muntins and<br />

a fixed upper<br />

double hung good, some<br />

w/wood chipping<br />

muntins and<br />

a fixed upper<br />

excellent<br />

with exterior<br />

wood framed<br />

screen<br />

good excellent yes no excellent south yes<br />

excellent good excellent no no good south yes<br />

156Ba<br />

double hung good, some<br />

w/wood chipping<br />

muntins and<br />

a fixed upper<br />

excellent good excellent,<br />

weight cord<br />

painted<br />

no no good south yes<br />

156Da<br />

double hung<br />

w/wood<br />

muntins<br />

not accessible not accessible not accessible not<br />

accessible<br />

not<br />

accessible<br />

not<br />

accessibl<br />

e<br />

not<br />

accessible<br />

south<br />

Window blocked by a<br />

testing maching and is<br />

unreachable to assess<br />

Straub Hall Window Condition Assessment - 13


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

156Db double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent good right weight no no good east yes<br />

with exterior<br />

cord missing<br />

wood framed<br />

screen<br />

156Dc<br />

156Dd<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

not accessible not accessible not accessible not<br />

accessible<br />

excellent<br />

excellent excellent<br />

with exterior<br />

wood framed<br />

screen<br />

good, lock<br />

and pulls are<br />

intact<br />

not<br />

accessible<br />

not not<br />

accessibl accessible<br />

e<br />

east<br />

Window blocked by a<br />

testing maching and is<br />

unreachable to assess<br />

no no good east the top section of the<br />

window was loose so it<br />

was unsafe to attempt<br />

to open the window<br />

yes<br />

168Cb<br />

168Ca<br />

170a<br />

S170a<br />

172a<br />

vinyl,<br />

horizontal<br />

slider<br />

vinyl,<br />

horizontal<br />

slider<br />

casement<br />

window with<br />

wood<br />

muntins<br />

6 pane fixed good, some<br />

window with chipping<br />

wood<br />

muntins<br />

6 pane<br />

double hung<br />

w/wood<br />

muntins<br />

excellent excellent flashed with<br />

metal<br />

excellent excellent flashed with<br />

metal<br />

excellent good good, minor<br />

moss<br />

accumulation<br />

good, some<br />

chipping<br />

excellent yes no excellent west bars and screens on<br />

new vinyl windows,<br />

exterior plants<br />

obstructing opening<br />

excellent yes no excellent north bars and screens on<br />

new vinyl windows<br />

new locking<br />

hardware -<br />

two sliders<br />

on top and<br />

two on<br />

bottom<br />

yes no excellent west altered from original<br />

configuration<br />

good excellent none no no good east has this window been<br />

replaced There seems<br />

to be groving for<br />

movement but it is<br />

unoperable.<br />

good<br />

good, moss<br />

accumulation<br />

good, lock yes no excellent west yes<br />

and pulls are<br />

intact<br />

yes<br />

yes<br />

yes<br />

yes<br />

Straub Hall Window Condition Assessment - 14


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

178a double hung<br />

w/wood<br />

muntins<br />

Paint<br />

excellent<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent excellent yes no excellent east yes<br />

with exterior<br />

wood framed<br />

screen<br />

178b<br />

double hung<br />

w/wood<br />

muntins<br />

good good, lower 3 not accessible excellent no no good west yes<br />

panels have<br />

been replaced<br />

with textured<br />

glass<br />

178c<br />

double hung<br />

w/wood<br />

muntins<br />

good<br />

excellent<br />

with exterior<br />

wood framed<br />

screen<br />

excellent excellent no no good west the top section of the<br />

window was loose so it<br />

was unsafe to attempt<br />

to open the window<br />

yes<br />

178Aa<br />

180a<br />

180b<br />

180c<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good excellent not<br />

accessible<br />

not<br />

accessible<br />

excellent excellent excellent excellent not<br />

accessible<br />

excellent<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

excellent<br />

with vertical<br />

blinds<br />

attached to<br />

casement<br />

excellent<br />

with vertical<br />

blinds<br />

attached to<br />

casing<br />

no good east This window was only<br />

able to be accessed from<br />

exterior<br />

no excellent east<br />

excellent excellent yes no excellent west yes<br />

good, some<br />

moss<br />

accumulation<br />

right weight no no good west yes<br />

cord missing<br />

Straub Hall Window Condition Assessment - 15


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

186a hopper with<br />

wood<br />

muntins<br />

186b<br />

189a<br />

189b<br />

191a<br />

hopper with<br />

wood<br />

muntins<br />

double<br />

casement<br />

double<br />

casement<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

excellent<br />

good, some<br />

chipping<br />

interior muntins<br />

and sash<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

interior muntins<br />

and sash<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

top of casing<br />

removed for<br />

pipe<br />

good<br />

good, one<br />

glass pane<br />

has wires<br />

good<br />

excellent<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

not accessible N/A no not<br />

accessibl<br />

e<br />

good, some<br />

moss<br />

accumulation<br />

good, minor<br />

moss<br />

accumulation<br />

good, minor<br />

moss<br />

accumulation<br />

good moss<br />

accumulation<br />

Facing<br />

Elev. Comments Photo<br />

yes<br />

fair west this window leads to a<br />

concerte cove below<br />

grade and does not let<br />

in air or much light at<br />

all<br />

excellent yes no excellent south yes<br />

excellent no no good south yes<br />

excellent no no good south yes<br />

missing<br />

pulls<br />

yes no good north yes<br />

Straub Hall Window Condition Assessment - 16


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

193a<br />

194a<br />

195a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

excellent, some<br />

chipping on<br />

exterior<br />

good<br />

Window<br />

Parts*<br />

good, wood<br />

framed<br />

screen<br />

attached<br />

outside<br />

excellent<br />

with<br />

horizontal<br />

blinds<br />

attached to<br />

casing<br />

good, bottom<br />

6 panels are<br />

wood, top 6<br />

panels are<br />

painted glass<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent missing yes no excellent north<br />

pulls<br />

good, some<br />

moss<br />

accumulation<br />

not accessible<br />

missing<br />

pulls<br />

good, lock yes, top falls<br />

and pulls are down if<br />

intact unlocked<br />

yes no good south yes<br />

no good north yes<br />

196a<br />

double hung<br />

w/wood<br />

muntins<br />

excellent<br />

excellent<br />

with exterior<br />

wood framed<br />

screen<br />

excellent excellent yes no excellent north yes<br />

196Aa<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

excellent good, minor<br />

with exterior moss<br />

wood framed accumulation<br />

screen<br />

missing<br />

pulls<br />

no, painted<br />

into place<br />

no excellent north This window does not<br />

appear on plans<br />

yes<br />

S198a<br />

fixed wood<br />

window with<br />

muntins<br />

excellent excellent good N/A no, not an<br />

operable<br />

window<br />

no excellent north yes<br />

Straub Hall Window Condition Assessment - 17


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

199a<br />

199b<br />

199Aa<br />

199Ab<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Conditions<br />

Window<br />

Paint<br />

Parts*<br />

good, some good, a few<br />

chipping on glass panels<br />

interior, are cracked<br />

extensive or broken<br />

chipping on<br />

exterior<br />

fair, extensive good good, minor<br />

flaking on<br />

moss<br />

muntins<br />

accumulation<br />

excellent excellent excellent excellent yes, but the<br />

top drops<br />

when<br />

unlocked<br />

excellent excellent good, minor<br />

moss<br />

accumulation<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

excellent missing no, top falls<br />

upper left down if<br />

cord unlocked<br />

Facing<br />

Elev. Comments Photo<br />

no good south the wood casing around yess<br />

this window is stained<br />

to match wainscot<br />

excellent yes no excellent east yes<br />

no excellent east the wood casing around<br />

this window is stained<br />

to match wainscot<br />

excellent yes no excellent north the wood casing around<br />

this window is stained<br />

to match wainscot<br />

yes<br />

yes<br />

201a<br />

201b<br />

202a<br />

202b<br />

H202a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

excellent<br />

good, some<br />

moss<br />

accumulation<br />

excellent excellent good, large<br />

amount of<br />

moss<br />

accumulation<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

stacked interior good,<br />

wood exterior poor<br />

awning<br />

window with<br />

muntins<br />

good, some<br />

splitting in<br />

the lower<br />

casing<br />

good<br />

good<br />

excellent yes no good east yes<br />

excellent<br />

not<br />

accessible<br />

no excellent north yes<br />

excellent excellent yes no good east yes<br />

good, metal<br />

sheathing<br />

covering sill<br />

good, metal<br />

sheathing<br />

covering sill<br />

excellent<br />

yes, a bit<br />

sticky<br />

missing lock yes, opens to<br />

rooftop<br />

no good east This window does not<br />

appear on plans<br />

yes<br />

no good south yes<br />

Straub Hall Window Condition Assessment - 18


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

203a double hung<br />

w/wood<br />

muntins<br />

204a<br />

stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

Conditions<br />

Paint<br />

excellent<br />

poor, sill w/out<br />

paint, deep<br />

flaking on<br />

exterior casing,<br />

interior muntins<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

Window<br />

Parts*<br />

excellent<br />

with scars<br />

from locks<br />

stool cracked sill flashed<br />

metal, good<br />

condition<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, large excellent, yes, a bit no good north yes<br />

amount of right weight sticky<br />

moss cord is<br />

accumulation freying<br />

excellent yes yes fair south interior muntins<br />

showing signs of past<br />

condensation<br />

accumulation<br />

yes<br />

204b<br />

stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

poor, sill<br />

out/out paint,<br />

deep flaking on<br />

exterior casing,<br />

interior muntins<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

lower jamb<br />

on upper<br />

window with<br />

multiple<br />

cracks at<br />

hardware<br />

attachment<br />

sill flashed<br />

metal, good<br />

condition<br />

excellent yes yes fair south interior muntins<br />

showing signs of past<br />

condensation<br />

accumulation<br />

yes<br />

205a<br />

207a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

excellent excellent good moss<br />

accumulation<br />

excellent<br />

excellent<br />

with<br />

horizontal<br />

blinds<br />

attached to<br />

casing<br />

good moss<br />

accumulation<br />

excellent yes no excellent north yes<br />

excellent<br />

not<br />

accessible<br />

no excellent north yes<br />

Straub Hall Window Condition Assessment - 19


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

208a<br />

209a<br />

210a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

excellent, some<br />

chipping on<br />

interior<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

Window<br />

Parts*<br />

stool<br />

damaged,<br />

lower 8 glass<br />

panes<br />

painted white<br />

good, few<br />

chips and<br />

dents<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

good, metal good, lock<br />

sheathing and pulls are<br />

covering sill intact<br />

good moss<br />

accumulation<br />

top window<br />

sits on<br />

exterior<br />

supports for<br />

ventilation,<br />

bottom is<br />

fixed<br />

Facing<br />

Elev. Comments Photo<br />

no fair south sill damage is from stall yes<br />

sizes changing through<br />

the years and the slot<br />

for stall supports<br />

moving<br />

excellent yes no good north yes<br />

excellent excellent yes no excellent south opens to rooftop yes<br />

210b<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

dropped good, mortar<br />

ceiling crack evident<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent yes no excellent south opens to rooftop yes<br />

210c<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent excellent not<br />

accessible<br />

no excellent south opens to rooftop<br />

Straub Hall Window Condition Assessment - 20


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

210d<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

dropped excellent double lock, yes no excellent south<br />

ceiling<br />

no pull<br />

attached to<br />

above<br />

upper casing,<br />

awning<br />

vertical<br />

blinds<br />

attached<br />

S210a<br />

211a<br />

212a<br />

H219a<br />

220a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

16 pane,<br />

double hung<br />

w/ wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, few<br />

chips and<br />

dents<br />

excellent excellent good, moss<br />

accumulation<br />

excellent<br />

excellent<br />

excellent<br />

with scars<br />

from locks<br />

excellent excellent no, painted<br />

into place<br />

good, large<br />

amount of<br />

moss<br />

accumulation<br />

excellent, good, some<br />

minor flaking moss<br />

on sill accumulation<br />

excellent excellent good moss<br />

accumulation<br />

lock is<br />

broken but<br />

functional<br />

excellent<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

no excellent south yes<br />

no excellent north yes<br />

no excellent north yes<br />

excellent yes no excellent east yes<br />

excellent fair, sticky no excellent north<br />

Straub Hall Window Condition Assessment - 21


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

221a<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

Conditions<br />

Window<br />

Paint<br />

Parts*<br />

excellent excellent good, moss<br />

accumulation<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent poor, very no excellent north<br />

sticky<br />

221b<br />

double hung fair, extensive<br />

w/wood flaking on sill<br />

muntins,<br />

opening from<br />

top & bottom<br />

excellent<br />

good, minor<br />

moss<br />

accumulation<br />

excellent excellent no excellent west<br />

223a<br />

double hung fair, extensive<br />

w/wood flaking on sill<br />

muntins,<br />

opening from<br />

top & bottom<br />

left jamb<br />

cracked, sill<br />

checked,<br />

good, minor<br />

moss<br />

accumulation<br />

upper left<br />

weight cord<br />

broken<br />

poor no fair east window not on current<br />

plan<br />

224a<br />

double hung fair, extensive<br />

w/wood flaking on sill<br />

muntins,<br />

opening from<br />

top & bottom<br />

excellent excellent excellent yes no excellent east<br />

225a<br />

double hung fair, extensive<br />

w/wood flaking on sill<br />

muntins,<br />

opening from<br />

top & bottom<br />

excellent<br />

good, some<br />

moss<br />

accumulation<br />

excellent<br />

yes, a bit<br />

sticky<br />

no excellent west<br />

226a<br />

stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

excellent excellent excellent yes no excellent east two large nails in sill yes<br />

Straub Hall Window Condition Assessment - 22


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

226b stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

227a double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

Conditions<br />

Window Brick Sill<br />

Facing<br />

Paint<br />

Parts* Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

excellent excellent excellent excellent yes no excellent east<br />

fair, extensive<br />

flaking on sill<br />

and outer casing<br />

upper jamb<br />

damaged<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no good west signs of past<br />

condensation<br />

accumulation on<br />

muntins<br />

228a<br />

228b<br />

229a<br />

stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

sill flaking excellent excellent excellent yes no excellent east opens onto fire escape<br />

stacked sill flaking excellent excellent excellent yes no excellent east<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

double hung fair, extensive stool cracked good, minor excellent yes no excellent west<br />

w/wood flaking on sill and repaired moss<br />

muntins, and outer casing<br />

accumulation<br />

opening from<br />

top & bottom<br />

230a<br />

stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

sill flaking excellent excellent excellent yes no excellent east opens onto fire escape<br />

Straub Hall Window Condition Assessment - 23


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

S230a<br />

231a<br />

16 pane,<br />

double hung<br />

w/ wood<br />

muntins<br />

Conditions<br />

Paint<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

sill flaking good excellent missing yes, a bit no good east yes<br />

upper left sticky<br />

cord<br />

double hung fair, extensive sill damaged good, some<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

flaking on sill<br />

and outer casing<br />

moss<br />

accumulation<br />

upper left<br />

cord broken<br />

yes no excellent west minor damage to upper<br />

sill on top window<br />

232a<br />

232b<br />

233a<br />

stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

sill flaking,<br />

minor flack on<br />

lower interior<br />

muntins due to<br />

past water<br />

accumulation<br />

sill flaking,<br />

minor flack on<br />

lower interior<br />

muntins due to<br />

past water<br />

accumulation<br />

no paint on sill,<br />

flaking on<br />

exterior casing<br />

excellent excellent excellent yes no excellent east<br />

excellent excellent excellent,<br />

top lock has<br />

been<br />

replaced<br />

excellent<br />

good, some<br />

moss<br />

accumulation<br />

yes no excellent east opens onto fire escape yes<br />

excellent yes no good west<br />

235a<br />

double hung flaking on sill<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

sash<br />

damaged<br />

good, some<br />

moss<br />

accumulation<br />

excellent yes no fair west top sash of top window<br />

deeply cracked<br />

Straub Hall Window Condition Assessment - 24


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

Window Brick Sill<br />

Facing<br />

# T y p e Paint<br />

Parts* Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

H236a N/A N/A N/A N/A N/A N/A N/A N/A east this is not a window but yes<br />

rather the elevator<br />

shaft. If a window once<br />

existed, all trace is gone<br />

237a<br />

double hung paint gone from<br />

w/wood sill<br />

muntins,<br />

opening from<br />

top & bottom<br />

jamb cracked,<br />

casing<br />

cracked<br />

good, some<br />

moss<br />

accumulation<br />

excellent yes no fair west casing and jamb on left<br />

side are cracked.<br />

238a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

excellent excellent excellent excellent,<br />

with cord<br />

protectors<br />

yes no excellent east yes<br />

239a<br />

double hung fair, flaking on<br />

w/wood sill and outer<br />

muntins, casing<br />

opening from<br />

top & bottom<br />

sash and<br />

muntins<br />

damaged by<br />

hardware<br />

rubbing<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no fair west sill used for planters yes<br />

240a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

flaking on sill excellent excellent Lots of<br />

leftover<br />

hardware<br />

remains on<br />

window, not<br />

currently<br />

serving any<br />

function<br />

yes no good east altered from original<br />

configuration<br />

yes<br />

Straub Hall Window Condition Assessment - 25


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

240b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Conditions<br />

Paint<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

flaking on sill excellent excellent excellent yes no good east cracked bottom sash on yes<br />

top window, upper sash<br />

on bottom window<br />

(appears to be result of<br />

hardware retrofit).<br />

241a<br />

double hung sill and bottom<br />

w/wood exterior casing<br />

muntins, flaking<br />

opening from<br />

top & bottom<br />

excellent<br />

good, some<br />

moss<br />

accumulation<br />

weight cord<br />

on lower<br />

right<br />

window<br />

broken<br />

OK, top<br />

window<br />

sticky<br />

no excellent west<br />

242a<br />

242b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

excellent excellent good, some<br />

moss<br />

accumulation<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

excellent excellent good, some<br />

moss<br />

accumulation<br />

excellent yes no excellent east yes<br />

excellent yes no excellent east<br />

243a<br />

double hung fair, extensive excellent good upper left<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

flaking on sill<br />

and outer casing<br />

cord broken<br />

OK no good north yes<br />

245a<br />

double hung fair<br />

w/wood<br />

muntins,<br />

opening from<br />

top & bottom<br />

excellent, good<br />

minor flaking<br />

on sill<br />

upper left<br />

cord broken<br />

OK no good north<br />

Straub Hall Window Condition Assessment - 26


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window<br />

#<br />

H245a<br />

Window<br />

T y p e<br />

**see L150a**<br />

Paint<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

H245b<br />

**see L150b**<br />

H245c<br />

**see L150c**<br />

251a<br />

double hung<br />

w/wood<br />

muntins<br />

fair, extensive good excellent right weight<br />

flaking on sill<br />

cord broken<br />

and outer casing<br />

no no good south yes<br />

252a<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

good,<br />

dropped<br />

ceiling<br />

attached at<br />

top<br />

excellent excellent yes no excellent east opens to rooftop yes<br />

253a<br />

254a<br />

double hung<br />

w/wood<br />

muntins<br />

12 pane<br />

double hung,<br />

with wood<br />

muntins<br />

good, some<br />

chipping<br />

good, vertical<br />

blinds<br />

attached at<br />

top<br />

excellent good, lower 6<br />

panels have<br />

been replaced<br />

with white<br />

painted<br />

wood<br />

good, some<br />

moss<br />

accumulation<br />

left weight<br />

cord broken<br />

no, top falls<br />

down if<br />

unlocked,<br />

bottom<br />

painted into<br />

place<br />

excellent excellent bottom is<br />

non-operable<br />

but top sinks<br />

2" resting on<br />

unseen<br />

exterior<br />

supports<br />

no good west yes<br />

no good east lower panels wood for<br />

privacy - this space is a<br />

restroom<br />

yes<br />

255a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

excellent<br />

good, some<br />

moss<br />

accumulation<br />

excellent<br />

not<br />

accessible<br />

no good west yes<br />

Straub Hall Window Condition Assessment - 27


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

256a<br />

257a<br />

258a<br />

258b<br />

259a<br />

270a<br />

270b<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

Window Brick Sill<br />

Facing<br />

Parts* Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

excellent good excellent yes no good east<br />

good, simple good, minor<br />

case to match moss<br />

wainscot accumulation<br />

excellent<br />

good, minor<br />

moss<br />

accumulation<br />

right case cut good, minor<br />

moss<br />

accumulation<br />

good,<br />

cracked stool<br />

good, moss<br />

accumulation<br />

excellent yes no excellent west yes<br />

right weight yes, but the<br />

cord missing top drops<br />

when<br />

unlocked<br />

excellent no, painted<br />

into place<br />

no good east yes<br />

no good east This window does not<br />

appear on plans<br />

excellent yes no good west yes<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached,<br />

excellent excellent yes no good<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent excellent yes no good<br />

east<br />

east<br />

split in bottom rail<br />

yes<br />

yes<br />

yes<br />

Straub Hall Window Condition Assessment - 28


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

S270a<br />

271a<br />

272a<br />

16 pane,<br />

double hung<br />

w/ wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

excellent excellent missing lock yes, very no good<br />

sticky<br />

splitting in<br />

case<br />

good, minor<br />

moss<br />

accumulation<br />

dropped good, minor<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent<br />

double lock,<br />

no pull<br />

above<br />

awning<br />

no, top falls<br />

down if<br />

unlocked<br />

Facing<br />

Elev. Comments Photo<br />

yes<br />

east<br />

no good west yes<br />

yes no good east<br />

272b<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

dropped good, minor<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

double lock,<br />

no pull<br />

above<br />

awning<br />

yes no good east<br />

273a<br />

274a<br />

double hung<br />

w/wood<br />

muntins<br />

12 pane<br />

double hung,<br />

with wood<br />

muntins<br />

good, some<br />

chipping<br />

excellent<br />

righ case in<br />

wall…<br />

all glass<br />

replaced with<br />

white painted<br />

wood<br />

good moss<br />

accumulation<br />

excellent<br />

yes, a bit<br />

sticky<br />

no good west yes<br />

excellent excellent yes no good east wood replacing glass<br />

for privacy - another<br />

restroom<br />

yes<br />

278a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, chips<br />

and dents<br />

excellent excellent not<br />

accessible<br />

no good east<br />

Straub Hall Window Condition Assessment - 29


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

Window<br />

# T y p e Paint<br />

Parts*<br />

278b double hung good, some good,<br />

w/wood chipping horizontal<br />

muntins<br />

blinds<br />

attached at<br />

top, chips<br />

and dents<br />

279a double hung good, some good, good moss excellent<br />

w/wood chipping horizontal accumulation<br />

muntins<br />

blinds<br />

attached at<br />

top<br />

279b double hung good, some good, good moss<br />

w/wood chipping horizontal accumulation<br />

muntins<br />

blinds<br />

attached at<br />

top, chips<br />

and dents<br />

283a not accessible not accessible not accessible not accessible not<br />

accessible<br />

283b not accessible not accessible not accessible not accessible not<br />

accessible<br />

284a<br />

284b<br />

S284a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

16 pane,<br />

double hung<br />

w/ wood<br />

muntins<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent not no good east<br />

accessible<br />

good, some<br />

moss<br />

accumulation<br />

good moss<br />

accumulation<br />

excellent excellent good, some<br />

moss<br />

accumulation<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

no good west yes<br />

excellent yes no good west yes<br />

broken right<br />

weight cord<br />

excellent<br />

excellent<br />

not<br />

accessible<br />

not<br />

accessible<br />

no, painted<br />

into place<br />

no, painted<br />

into place<br />

no, painted<br />

into place<br />

not<br />

accessibl<br />

e<br />

not<br />

accessibl<br />

e<br />

N/A west this room is under lock<br />

and key due to<br />

confidential files<br />

N/A west this room is under lock<br />

and key due to<br />

confidential files<br />

no good south yes<br />

no good south yes<br />

no good east yes<br />

Straub Hall Window Condition Assessment - 30


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

H286a stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

H286b stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

H286c stacked<br />

wood<br />

awning<br />

windows<br />

with wood<br />

muntins<br />

287a double hung<br />

w/wood<br />

muntins<br />

288a<br />

289a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Conditions<br />

Paint<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent good, some excellent bottom is no good north yes<br />

moss<br />

operable, top<br />

accumulation<br />

is not<br />

excellent excellent good, moss<br />

accumulation<br />

good, some<br />

chipping<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

excellent<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, split in<br />

casing<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

excellent<br />

good, some<br />

moss<br />

accumulation<br />

good, minor<br />

moss<br />

accumulation<br />

good<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no excellent north yes<br />

missing<br />

pulls<br />

excellent<br />

left weight<br />

cord broken<br />

missing<br />

upper left<br />

cord<br />

yes no good north yes<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

no good south<br />

yes, top sinks no good south<br />

no, painted<br />

into place<br />

no good north<br />

Straub Hall Window Condition Assessment - 31


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

290a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Conditions<br />

Window<br />

Paint<br />

Parts*<br />

excellent excellent good, minor<br />

moss<br />

accumulation<br />

Brick Sill<br />

Facing<br />

Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

excellent yes no good north<br />

290b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

excellent excellent good, minor<br />

moss<br />

accumulation<br />

excellent yes no good north<br />

S290a<br />

291a<br />

16 pane, good, some<br />

double hung chipping<br />

w/ wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

excellent<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good, some<br />

moss<br />

accumulation<br />

good, minor<br />

moss<br />

accumulation<br />

broken cord<br />

on left<br />

no no good north yes<br />

excellent yes no excellent south yes<br />

Straub Hall Window Condition Assessment - 32


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

292a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Conditions<br />

Window<br />

Paint<br />

Parts*<br />

excellent excellent good moss<br />

accumulation<br />

Brick Sill<br />

Facing<br />

Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

excellent yes no excellent north<br />

292b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

excellent excellent good moss<br />

accumulation<br />

excellent yes no excellent north<br />

293a<br />

294a<br />

295a<br />

295b<br />

295c<br />

double hung<br />

w/wood<br />

muntins<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

excellent<br />

good, minor<br />

moss<br />

accumulation<br />

excellent<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

no excellent south yes<br />

excellent good, lower 8 not accessible excellent no no good north<br />

panels have<br />

been painted<br />

white<br />

double hung w/wood muntins<br />

double hung excellent excellent good, minor excellent yes no excellent south yes<br />

w/wood interior, severe<br />

moss<br />

muntins chipping on<br />

accumulation<br />

exterior<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

good, some<br />

chipping<br />

excellent,<br />

horizontal<br />

and vinyl<br />

blinds<br />

attached<br />

excellent,<br />

horizontal<br />

and vinyl<br />

blinds<br />

attached<br />

good, minor<br />

moss<br />

accumulation<br />

good moss<br />

accumulation<br />

excellent yes no excellent south yes<br />

excellent<br />

no, painted<br />

into place<br />

no excellent east yes<br />

Straub Hall Window Condition Assessment - 33


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

298a<br />

298b<br />

301a<br />

301b<br />

302a<br />

302b<br />

H302a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Conditions<br />

Paint<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

excellent<br />

excellent excellent good, some<br />

moss<br />

accumulation<br />

good, some<br />

chipping<br />

excellent<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

good, some<br />

chipping<br />

stacked interior is good<br />

wood with minimal<br />

awning chipping,<br />

window with exterior is very<br />

muntins poor with<br />

extensive<br />

chipping<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good moss excellent not no good east<br />

accumulation<br />

accessible<br />

good, some<br />

moss<br />

accumulation<br />

good, some<br />

moss<br />

accumulation<br />

excellent<br />

excellent<br />

not<br />

accessible<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

no excellent north<br />

no good east<br />

excellent yes no good north<br />

excellent excellent yes, but the<br />

top drops<br />

when<br />

unlocked<br />

good, some<br />

moss<br />

accumulation<br />

excellent<br />

no, painted<br />

into place<br />

no good south yes<br />

no good east<br />

excellent excellent excellent yes no excellent south yes<br />

Straub Hall Window Condition Assessment - 34


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

H302b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Conditions<br />

Window<br />

Paint<br />

Parts*<br />

excellent excellent excellent excellent, all<br />

new<br />

hardware<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

yes no excellent south this window to seems to yes<br />

be new construction. It<br />

has new hardware and<br />

does not appear as a<br />

window with casement<br />

on the current plans<br />

303a<br />

304a<br />

304b<br />

double hung<br />

w/wood<br />

muntins<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

excellent<br />

poor, sill w/out<br />

paint, deep<br />

flaking on<br />

exterior casing,<br />

interior muntins<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

poor, sill w/out<br />

paint, deep<br />

flaking on<br />

exterior casing,<br />

interior muntins<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

minor<br />

cracking or<br />

splitting in<br />

casing<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no good north yes<br />

excellent excellent yes no good south most 'damage' to this<br />

window is superficial<br />

and can be repaired<br />

excellent excellent yes no good south most 'damage' to this<br />

window is superficial<br />

and can be repaired<br />

yes<br />

305a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, vertical<br />

blinds<br />

attached at<br />

top<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no excellent north yes<br />

Straub Hall Window Condition Assessment - 35


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

307a double hung<br />

w/wood<br />

muntins<br />

308a<br />

309a<br />

310a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Conditions<br />

Paint<br />

excellent<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good, lower 8<br />

panels have<br />

been painted<br />

white<br />

excellent<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, some excellent yes, a bit no excellent north<br />

moss<br />

sticky<br />

accumulation<br />

good, some<br />

deterioration of<br />

mortar joints<br />

good, some<br />

moss<br />

accumulation<br />

new lock on<br />

right,<br />

missing left<br />

weight cord<br />

excellent<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

not accessible not accessible not accessible not<br />

accessible<br />

yes no good south yes<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

not<br />

accessible<br />

no good north yes<br />

not<br />

accessibl<br />

e<br />

N/A south blocked by bookcases<br />

and furniture<br />

310b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

poor, sill w/out<br />

paint, deep<br />

flaking on<br />

exterior casing,<br />

interior muntins<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent excellent yes no good south yes<br />

Straub Hall Window Condition Assessment - 36


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

310c<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Conditions<br />

Paint<br />

poor, sill w/out<br />

paint, deep<br />

flaking on<br />

exterior casing,<br />

interior muntins<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

Window<br />

Parts*<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

Brick Sill<br />

Facing<br />

Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

excellent excellent yes no good south yes<br />

310d<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

poor, sill w/out<br />

paint, deep<br />

flaking on<br />

exterior casing,<br />

interior muntins<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent excellent yes no good south yes<br />

S310a<br />

311a<br />

312a<br />

double hung,<br />

rounded<br />

arch, 32 pane<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

interior is good<br />

with minimal<br />

chipping,<br />

exterior is very<br />

poor with<br />

extensive<br />

chipping<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

good, lower<br />

portion may<br />

be newer<br />

construction<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

excellent<br />

good moss<br />

accumulation<br />

good moss<br />

accumulation<br />

missing<br />

pulls<br />

no no good south This is a double height<br />

window and is also<br />

qualified as S410a<br />

excellent yes no good north<br />

excellent yes no good north<br />

yes<br />

Straub Hall Window Condition Assessment - 37


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

H319a<br />

320a<br />

321a<br />

321b<br />

323a<br />

324a<br />

double hung<br />

16 pane<br />

w/wood<br />

muntins,<br />

opening from<br />

bottom<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

interior is good<br />

with minimal<br />

chipping,<br />

exterior is very<br />

poor with<br />

extensive<br />

chipping<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

excellent<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent excellent no, top falls no good east yes<br />

down if<br />

unlocked<br />

split in case,<br />

horizontal<br />

blinds<br />

attached<br />

excellent<br />

with vertical<br />

blinds<br />

attached to<br />

casement<br />

excellent<br />

with vertical<br />

blinds<br />

attached to<br />

casement<br />

excellent<br />

with vertical<br />

blinds<br />

attached to<br />

casement<br />

good, vertical<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

case<br />

good, moss<br />

accumulation<br />

good, minor<br />

moss<br />

accumulation<br />

good, some<br />

moss<br />

accumulation<br />

good, minor<br />

moss<br />

accumulation<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no excellent north yes<br />

excellent yes no excellent north<br />

excellent<br />

not<br />

accessible<br />

no excellent west<br />

excellent yes no excellent west yes<br />

broken cord<br />

on left<br />

top sinks,<br />

bottom no<br />

(painted)<br />

no good east yes<br />

Straub Hall Window Condition Assessment - 38


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

325a<br />

326a<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

Window<br />

Parts*<br />

split in case,<br />

horizontal<br />

blinds<br />

attached<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, minor missing yes no good west yes<br />

moss pulls<br />

accumulation<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent excellent yes no good east yes<br />

326b<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

dropped good, minor<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent yes no good east<br />

327a<br />

328a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

stacked excellent<br />

wood interior, severe<br />

awning chipping on<br />

window with exterior<br />

muntins<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good, minor<br />

moss<br />

accumulation<br />

dropped good, minor<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent yes no excellent west<br />

excellent yes no excellent east<br />

Straub Hall Window Condition Assessment - 39


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

328b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

excellent<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

dropped excellent excellent yes no excellent east yes<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

329a<br />

S330a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

double hung, good, some<br />

rounded chipping<br />

arch, 32 pane<br />

w/wood<br />

muntins<br />

excellent,<br />

horizontal<br />

and vinyl<br />

blinds<br />

attached<br />

excellent excellent yes, but the<br />

top drops<br />

when<br />

unlocked<br />

excellent excellent broken cord<br />

on left<br />

no excellent west<br />

no no good east This is a double height<br />

window and is also<br />

qualified as S430a<br />

yes<br />

331a<br />

H331a<br />

double hung<br />

w/wood<br />

muntins<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

excellent excellent yes, but the<br />

top drops<br />

when<br />

unlocked<br />

excellent excellent excellent pull on<br />

upper<br />

awning was<br />

replaced<br />

with another<br />

lock<br />

no, locked<br />

into place<br />

no good west<br />

no fair east yes<br />

Straub Hall Window Condition Assessment - 40


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

332a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

dropped excellent excellent yes no good east yes<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

332b<br />

stacked excellent<br />

wood interior, severe<br />

awning chipping on<br />

window with exterior<br />

muntins<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent excellent yes no good east<br />

333a<br />

335a<br />

H336a<br />

337a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

excellent<br />

interior, severe<br />

chipping on<br />

exterior<br />

good, some<br />

chipping<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, split in<br />

jamb<br />

good, some<br />

moss<br />

accumulation<br />

good, some<br />

moss<br />

accumulation<br />

double hung excellent excellent good, some<br />

16 pane<br />

w/wood<br />

muntins,<br />

opening from<br />

bottom<br />

moss<br />

accumulation<br />

double hung<br />

w/wood<br />

muntins<br />

excellent<br />

interior, some<br />

chipping on<br />

exterior<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

good, minor<br />

moss<br />

accumulation<br />

broken cord<br />

on right, no<br />

pulls<br />

missing left<br />

pull<br />

excellent,<br />

with cord<br />

protectors<br />

excellent<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

no good east yes<br />

yes no good west yes<br />

no, top falls<br />

down if<br />

unlocked,<br />

bottom<br />

painted into<br />

place<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

no fair east yes<br />

no excellent west<br />

Straub Hall Window Condition Assessment - 41


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

337b<br />

338a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

12 pane w/<br />

wood<br />

muntins<br />

Paint<br />

excellent<br />

interior, some<br />

chipping on<br />

exterior<br />

excellent<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, good, minor missing yes, but the no good west yes<br />

horizontal moss upper left top drops<br />

blinds accumulation cord when<br />

attached at<br />

unlocked<br />

top, crack in<br />

stool<br />

all<br />

good excellent, no, painted no good east yes<br />

transparent<br />

with cord into place<br />

glass<br />

protectors<br />

replaced with<br />

textured or<br />

frosted glass<br />

339a<br />

H340a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

stacked interior is<br />

wood exxcellent,<br />

awning exterior is good<br />

window with with some<br />

muntins chipping<br />

good, some good, some<br />

chips and moss<br />

cracks in case accumulation<br />

excellent<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

no good west yes<br />

excellent excellent excellent yes no excellent east yes<br />

341a<br />

342a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

stacked good, some<br />

wood chipping on<br />

awning interior,<br />

window with extensive<br />

muntins chipping on<br />

exterior<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no good west<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent excellent yes no excellent east yes<br />

Straub Hall Window Condition Assessment - 42


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

342b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

dropped excellent excellent yes no excellent east<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

343a<br />

344a<br />

344b<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, split in<br />

case<br />

excellent excellent yes no good west<br />

dropped excellent excellent yes no excellent east<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

vertical<br />

blinds<br />

attached,<br />

cracks on<br />

exterior of<br />

innner sash<br />

excellent excellent yes no good east yes<br />

Straub Hall Window Condition Assessment - 43


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

345a<br />

346a<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

Window<br />

Parts*<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, minor excellent yes, top sinks no good west<br />

moss<br />

accumulation<br />

dropped good, minor<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

vertical<br />

blinds<br />

attached,<br />

added strip<br />

on stool<br />

excellent yes no good east yes<br />

346b<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

dropped good, minor<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

vertical<br />

blinds<br />

attached<br />

excellent yes no good east<br />

347a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, vertical<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

case<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no good west yes<br />

348a<br />

stacked good, some<br />

wood chipping on<br />

awning interior,<br />

window with extensive<br />

muntins chipping on<br />

exterior<br />

some<br />

cracking in<br />

the sash<br />

excellent excellent yes no good east<br />

Straub Hall Window Condition Assessment - 44


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

348b<br />

349a<br />

350a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping<br />

stacked excellent<br />

wood interior, some<br />

awning chipping on<br />

window with exterior<br />

muntins<br />

Window<br />

Parts*<br />

some<br />

cracking in<br />

the sash<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached and<br />

some<br />

cracking in<br />

stool<br />

Brick Sill<br />

Facing<br />

Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

excellent excellent yes no good east yes<br />

good, minor<br />

moss<br />

accumulation,<br />

with a chip on<br />

one brick edge<br />

missing left<br />

weight cord<br />

no no good west yes<br />

good excellent yes no good east yes<br />

350b<br />

stacked excellent<br />

wood interior, some<br />

awning chipping on<br />

window with exterior<br />

muntins<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

good excellent yes no good east<br />

351a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, vertical<br />

blinds<br />

attached at<br />

top<br />

good, minor<br />

moss<br />

accumulation<br />

missing lock yes no good west yes<br />

Straub Hall Window Condition Assessment - 45


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

352a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

dropped excellent excellent yes no good east yes<br />

ceiling<br />

attached to<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached,<br />

sash pulling<br />

away from<br />

itself<br />

352b<br />

353a<br />

354a<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

Picture good, some<br />

window with chipping<br />

awning, 12<br />

panes and<br />

wood<br />

muntins<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached,<br />

sash pulling<br />

away from<br />

itself<br />

excellent excellent yes no excellent east<br />

excellent good, minor<br />

moss<br />

accumulation<br />

excellent yes no excellent west<br />

good excellent double lock, yes no good east yes<br />

no pull<br />

above<br />

awning<br />

Straub Hall Window Condition Assessment - 46


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

355a<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

excellent<br />

interior, some<br />

chipping on<br />

exterior<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, vertical good, some excellent yes no good west yes<br />

blinds moss<br />

attached at accumulation<br />

top, small<br />

crack in<br />

casing<br />

356a<br />

double hung<br />

w/wood<br />

muntins<br />

poor, sill w/out splitting in<br />

paint, deep case and<br />

flaking on sash, with<br />

exterior casing, horizontal<br />

interior muntins blinds<br />

showing signs attached at<br />

of past top of case<br />

condensation<br />

accumulation<br />

excellent excellent yes no good east yes<br />

357a<br />

358a<br />

359a<br />

370a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

excellent<br />

interior, some<br />

chipping on<br />

exterior<br />

good, some<br />

chipping<br />

stacked excellent<br />

wood interior, some<br />

awning chipping on<br />

window with exterior<br />

muntins<br />

excellent<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing<br />

good, some<br />

moss<br />

accumulation<br />

good, some<br />

chipping on<br />

corners of<br />

bricks<br />

good, some<br />

moss<br />

accumulation<br />

missing lock yes no excellent west<br />

excellent yes no excellent east yes<br />

excellent yes no excellent west<br />

excellent excellent yes no excellent east<br />

Straub Hall Window Condition Assessment - 47


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

370b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

excellent<br />

interior, some<br />

chipping on<br />

exterior<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

dropped excellent new lock on yes no excellent east yes<br />

ceiling<br />

lower right<br />

attached to<br />

upper casing<br />

S370a<br />

371a<br />

H372a<br />

373a<br />

double hung,<br />

rounded<br />

arch, 32 pane<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Picture<br />

window with<br />

awning, 12<br />

panes and<br />

wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

interior is good<br />

with minimal<br />

chipping,<br />

exterior is very<br />

poor with<br />

extensive<br />

chipping<br />

good, some<br />

chipping<br />

good excellent good yes no good east This is a double height<br />

window and is also<br />

qualified as S470a<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good, some<br />

moss<br />

accumulation<br />

excellent good good, some<br />

moss<br />

accumulation<br />

good, some<br />

chipping<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good, some<br />

moss<br />

accumulation<br />

right weight<br />

cord broken<br />

intact nonpainted<br />

lock<br />

and pull<br />

with an<br />

additional<br />

locking<br />

mechanism<br />

excellent<br />

no no good west<br />

yes no good east the new lock is because<br />

the old lock's groove no<br />

longer holds the<br />

original lock in place<br />

yes, but the<br />

top drops<br />

when<br />

unlocked<br />

no good west<br />

yes<br />

yes<br />

Straub Hall Window Condition Assessment - 48


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

375a<br />

377a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good, vertical<br />

blinds<br />

attached at<br />

top<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, some excellent yes no good west yes<br />

moss<br />

accumulation<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes, top sinks no good west<br />

380a<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

dropped good, minor<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

excellent yes no excellent east<br />

380b<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

dropped good, minor<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

excellent yes no excellent east attachemnts remain for<br />

unknown object in<br />

header<br />

yes<br />

380c<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

dropped good, minor<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

excellent yes no excellent east<br />

Straub Hall Window Condition Assessment - 49


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

380d<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

dropped excellent new lock on yes no excellent east<br />

ceiling<br />

lower right<br />

attached to<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

381a<br />

382a<br />

383a<br />

S384a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

double hung good, some<br />

16 pane chipping<br />

w/wood<br />

muntins,<br />

opening from<br />

bottom<br />

good, roll<br />

down blinds<br />

attached at<br />

top of case<br />

good, lower 8<br />

panels have<br />

been painted<br />

white and<br />

urinal is<br />

attached to<br />

front of<br />

case/stool<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good, moss<br />

accumulation<br />

excellent yes no good west<br />

excellent excellent top window<br />

sits on<br />

exterior<br />

supports for<br />

ventilation,<br />

bottom is<br />

fixed<br />

good, some<br />

moss<br />

accumulation<br />

both weight<br />

cords are<br />

broken<br />

no, because<br />

of lack of<br />

cords<br />

no good east<br />

no good west yes<br />

good excellent good yes no excellent east yes<br />

Straub Hall Window Condition Assessment - 50


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

385a double hung<br />

w/wood<br />

muntins<br />

385b<br />

386a<br />

387a<br />

387Aa<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

excellent<br />

good, some<br />

chipping<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

Window<br />

Parts*<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good, blinds<br />

attached at<br />

top, crack in<br />

stool<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, minor excellent yes, top sinks no good west<br />

moss<br />

accumulation<br />

good, moss<br />

accumulation<br />

good, moss<br />

accumulation<br />

good, minor<br />

moss<br />

accumulation<br />

excellent<br />

not<br />

accessible<br />

no good south<br />

excellent yes no fair south yes<br />

missing<br />

right pull<br />

yes, but the<br />

top drops<br />

when<br />

unlocked,<br />

bottom is<br />

stuck<br />

excellent excellent yes, top sinks no excellent south<br />

no good south yes<br />

Straub Hall Window Condition Assessment - 51


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

388a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

bottom<br />

casing and<br />

stool have<br />

been<br />

removed, and<br />

major cracks<br />

appear in<br />

remaining<br />

case<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

good, minor<br />

moss<br />

accumulation<br />

Facing<br />

Elev. Comments Photo<br />

excellent yes no fair north bottom of casing has yes<br />

been removed and will<br />

have to be<br />

reconstructed<br />

388b<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

bottom good, moss<br />

casing and accumulation<br />

stool have<br />

been<br />

removed, and<br />

major cracks<br />

appear in<br />

remaining<br />

case<br />

excellent yes no fair north bottom of casing has<br />

been removed and will<br />

have to be<br />

reconstructed<br />

yes<br />

389a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, one glass<br />

pane cracked<br />

excellent excellent yes, top sinks no good south yes<br />

H389a<br />

Picture<br />

window with<br />

awning, 12<br />

panes and<br />

wood<br />

muntins<br />

excellent good good, moss<br />

accumulation<br />

good yes no excellent north yes<br />

Straub Hall Window Condition Assessment - 52


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

390a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

excellent<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

dropped good, minor excellent yes no excellent north<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

390b<br />

stacked excellent<br />

wood<br />

awning<br />

window with<br />

muntins<br />

dropped good, minor<br />

ceiling moss<br />

attached to accumulation<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

slide lock<br />

disabled,<br />

new side<br />

lock<br />

yes, now<br />

operates as a<br />

casement<br />

window<br />

no good north altered from original<br />

configuration<br />

yes<br />

391a<br />

392a<br />

double hung<br />

w/wood<br />

muntins<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

excellent<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good, some<br />

spalling of<br />

bricks<br />

excellent yes no excellent south<br />

dropped<br />

ceiling<br />

attached to<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

good excellent yes no excellent north<br />

Straub Hall Window Condition Assessment - 53


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

392b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

excellent<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

dropped good excellent yes not excellent<br />

ceiling<br />

accessibl<br />

attached to<br />

e<br />

upper casing,<br />

horizontal<br />

blinds<br />

attached<br />

Facing<br />

Elev. Comments Photo<br />

north<br />

393a<br />

394a<br />

double hung<br />

w/wood<br />

muntins<br />

16 pane,<br />

double hung<br />

w/ wood<br />

muntins<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, a few<br />

cracks in<br />

glass<br />

excellent good, lower 8<br />

panels have<br />

been painted<br />

white<br />

good, minor<br />

moss<br />

accumulation<br />

good, some<br />

moss<br />

accumulation<br />

excellent yes no good south<br />

broken left<br />

cord<br />

bottom is<br />

non-operable<br />

but top sinks<br />

2" resting on<br />

unseen<br />

exterior<br />

supports<br />

no good north yes<br />

395a<br />

397a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good, one<br />

muntin<br />

severely<br />

deteriorated<br />

good, minor<br />

moss<br />

accumulation<br />

good, some<br />

moss<br />

accumulation<br />

missing left<br />

weight cord<br />

both weight<br />

cords are<br />

broken<br />

yes, top sinks no good south<br />

yes, top sinks no good south yes<br />

Straub Hall Window Condition Assessment - 54


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

397b<br />

398a<br />

398b<br />

S398a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

excellent<br />

double hung, excellent<br />

rounded<br />

arch, 32 pane<br />

w/wood<br />

muntins<br />

Window<br />

Parts*<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

casing is<br />

cracking at<br />

top right and<br />

mid-arch<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, moss missing left not no good east<br />

accumulation weight cord accessible<br />

good, moss<br />

accumulation<br />

good, some<br />

moss<br />

accumulation<br />

good, some<br />

moss<br />

accumulation<br />

excellent yes no good east yes<br />

broken right<br />

weight cord<br />

broken left<br />

cord<br />

yes no good north yes<br />

no no good north This is a double height<br />

window and is also<br />

qualified as S498a<br />

yes<br />

401a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

excellent excellent excellent new lock<br />

and pull<br />

yes no excellent south this window appears to yes<br />

have been reconstructed<br />

recently<br />

401b<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, vertical<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

case<br />

excellent excellent yes no good north yes<br />

Straub Hall Window Condition Assessment - 55


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

401Aa double hung<br />

w/wood<br />

muntins<br />

Conditions<br />

Paint<br />

poor, sill w/out<br />

paint, deep<br />

flaking on<br />

exterior casing,<br />

interior muntins<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

Window<br />

Parts*<br />

splitting in<br />

case, large<br />

chunk<br />

missing from<br />

upper left<br />

case<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, some excellent not no fair south yes<br />

concrete<br />

accessible<br />

401Ab<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping, some<br />

moisture<br />

damage on<br />

muntins<br />

good, vertical<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

case<br />

excellent excellent yes no good east<br />

401Ac<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, vertical<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

case<br />

excellent excellent yes no excellent east<br />

401Ad<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, vertical<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

case<br />

excellent<br />

broken right<br />

weight cord<br />

no no good north yes<br />

H402a<br />

stacked excellent, dark<br />

wood brown rather<br />

awning than salmon or<br />

window with white<br />

muntins<br />

excellent excellent new lock<br />

and pull<br />

no, taped off no excellent south yes<br />

Straub Hall Window Condition Assessment - 56


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

404a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Conditions<br />

Paint<br />

poor, sill w/out<br />

paint, deep<br />

flaking on<br />

exterior casing,<br />

interior muntins<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

Window<br />

Parts*<br />

poor, sash<br />

and muntins<br />

are damaged<br />

(condensatio<br />

n<br />

accumulation<br />

)<br />

Brick Sill<br />

Facing<br />

Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

excellent excellent yes yes fair south yes<br />

404b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

poor, sill w/out<br />

paint, deep<br />

flaking on<br />

exterior casing,<br />

interior muntins<br />

showing signs<br />

of past<br />

condensation<br />

accumulation<br />

poor, sash<br />

and muntins<br />

are damaged<br />

(condensatio<br />

n<br />

accumulation<br />

)<br />

excellent excellent yes yes fair south yes<br />

405a<br />

406a<br />

407a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping<br />

excellent,<br />

vertical<br />

blinds<br />

attached<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good, minor<br />

splitting in<br />

case<br />

excellent excellent not<br />

accessible<br />

no excellent north<br />

excellent new lock yes no excellent south<br />

excellent<br />

broken right<br />

weight cord<br />

no no good north<br />

Straub Hall Window Condition Assessment - 57


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

408a<br />

408b<br />

408c<br />

408d<br />

409a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Conditions<br />

Paint<br />

fair, paint<br />

generally in<br />

good condition<br />

except for<br />

sash/muntins<br />

showing signs<br />

of moisture<br />

damage<br />

stacked fair, paint<br />

wood generally in<br />

awning good condition<br />

window with except for<br />

muntins sash/muntins<br />

showing signs<br />

of moisture<br />

damage<br />

stacked fair, paint<br />

wood generally in<br />

awning good condition<br />

window with except for<br />

muntins sash/muntins<br />

showing signs<br />

of moisture<br />

damage<br />

stacked fair, paint<br />

wood generally in<br />

awning good condition<br />

window with except for<br />

muntins sash/muntins<br />

showing signs<br />

of moisture<br />

damage<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

good, some<br />

signs of<br />

moisture<br />

damage<br />

good, some<br />

signs of<br />

moisture<br />

damage<br />

good, some<br />

signs of<br />

moisture<br />

damage<br />

good, some<br />

signs of<br />

moisture<br />

damage<br />

good, minor<br />

splitting in<br />

case<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent not no good south<br />

accessible<br />

excellent excellent not<br />

accessible<br />

excellent excellent yes no good south<br />

excellent excellent yes no good south<br />

good, some<br />

moss<br />

accumulation<br />

yes fair south yes<br />

excellent yes no excellent north yes<br />

S410a **see S310a** south<br />

Straub Hall Window Condition Assessment - 58


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

411a double hung<br />

w/wood<br />

muntins<br />

Paint<br />

excellent<br />

Window<br />

Parts*<br />

excellent, roll<br />

down blinds<br />

attached<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent yes, top sinks no excellent north<br />

413a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good amount excellent excellent yes no good north yes<br />

of splitting in<br />

case<br />

419a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no excellent north<br />

H419a **see H319a** east<br />

420a<br />

420b<br />

420c<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, some<br />

chipping, some<br />

moisture<br />

damage on<br />

muntins<br />

good, some<br />

chipping, some<br />

moisture<br />

damage on<br />

muntins<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, cracking<br />

in exterior<br />

sash<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no excellent north<br />

excellent excellent not<br />

accessible<br />

no good west yes<br />

excellent excellent yes no good west yes<br />

Straub Hall Window Condition Assessment - 59


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

422a<br />

423a<br />

424a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Conditions<br />

Paint<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

stacked good, some<br />

wood chipping, some<br />

awning moisture<br />

window with damage on<br />

muntins muntins<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, lower 8 not accessible missing left top window not good east restroom<br />

panels have<br />

pull sits on accessibl<br />

been painted<br />

exterior e<br />

white<br />

supports for<br />

ventilation,<br />

bottom is<br />

fixed<br />

good, good, minor excellent not no good west yes<br />

horizontal moss<br />

accessible<br />

blinds accumulation<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

signs of<br />

moisture<br />

damage on<br />

sash and<br />

muntins<br />

excellent excellent yes no good east<br />

424b<br />

stacked good, some<br />

wood chipping, some<br />

awning moisture<br />

window with damage on<br />

muntins muntins<br />

signs of<br />

moisture<br />

damage on<br />

sash and<br />

muntins<br />

excellent excellent yes no good east<br />

425a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

excellent excellent yes no good west<br />

Straub Hall Window Condition Assessment - 60


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

425b<br />

426a<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, excellent excellent yes no good west<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good, vertical excellent no pull not no fair east yes<br />

blinds<br />

accessible<br />

attached at<br />

top, crack in<br />

stool<br />

426b<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

good, vertical<br />

blinds<br />

attached at<br />

top<br />

excellent excellent yes no good east<br />

427a<br />

H427a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

stacked excellent, dark<br />

wood brown rather<br />

awning than salmon or<br />

window with white<br />

muntins<br />

splitting in<br />

case,<br />

chipping in<br />

sash and<br />

muntins<br />

excellent,<br />

shared<br />

casement<br />

with fire door<br />

excellent<br />

right weight<br />

cord needs<br />

to be<br />

replaced<br />

excellent excellent no, painted<br />

into place<br />

yes no good west yes<br />

no good east yes<br />

428a<br />

stacked good, some<br />

wood chipping on<br />

awning interior,<br />

window with extensive<br />

muntins chipping on<br />

exterior<br />

good, vertical<br />

blinds<br />

attached at<br />

top<br />

excellent excellent yes no excellent east<br />

Straub Hall Window Condition Assessment - 61


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

428b<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Conditions<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, vertical excellent excellent yes no excellent east<br />

blinds<br />

attached at<br />

top<br />

429a not accessible not accessible not accessible not accessible not<br />

accessible<br />

not<br />

accessible<br />

not not<br />

accessibl accessible<br />

e<br />

S430 **see S330a** east<br />

west<br />

431a<br />

H432a<br />

433a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

12 pane w/<br />

wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

excellent, dark<br />

brown rather<br />

than salmon or<br />

white, exterior<br />

has some<br />

chipping<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, roll<br />

down blinds<br />

attached at<br />

top of case,<br />

some<br />

splitting in<br />

case<br />

excellent,<br />

shared<br />

casement<br />

with fire door<br />

good, vertical<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

case<br />

good, minor<br />

moss<br />

accumulation<br />

excellent<br />

excellent no no good west yes<br />

missing pull no, painted<br />

into place<br />

no good east yes<br />

excellent excellent yes no good west yes<br />

Straub Hall Window Condition Assessment - 62


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

435a<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

some excellent excellent yes no good west yes<br />

splitting in<br />

case, also<br />

signs of past<br />

condensation<br />

accumulation<br />

on the lower<br />

muntins<br />

441a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, one glass<br />

pane cracked<br />

excellent excellent yes no excellent west<br />

H442a<br />

443a<br />

443b<br />

stacked excellent, dark<br />

wood brown rather<br />

awning than salmon or<br />

window with white, exterior<br />

muntins has some<br />

chipping<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

excellent excellent pull is of a no, painted<br />

different sort into place<br />

than the rest<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

excellent excellent not<br />

accessible<br />

excellent excellent not<br />

accessible<br />

no good east yes<br />

no excellent west<br />

no good west<br />

Straub Hall Window Condition Assessment - 63


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

444a<br />

444b<br />

445a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

stacked good, some<br />

wood chipping on<br />

awning interior,<br />

window with extensive<br />

muntins chipping on<br />

exterior<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

signs on past<br />

condensation<br />

accumulation<br />

Brick Sill<br />

Facing<br />

Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

excellent excellent yes no good east<br />

excellent excellent yes no good east<br />

good, some<br />

moss<br />

accumulation<br />

excellent<br />

not<br />

accessible<br />

no good west<br />

451a<br />

double hung<br />

w/wood<br />

muntins<br />

excellent<br />

interior, some<br />

chipping on<br />

exterior<br />

good, vertical<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

case<br />

good, minor<br />

moss<br />

accumulation<br />

left weight<br />

cord broken<br />

no no good west<br />

Straub Hall Window Condition Assessment - 64


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

446a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Conditions<br />

Paint<br />

good, some<br />

chipping, some<br />

moisture<br />

damage on<br />

muntins<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, vertical excellent pull on yes no good east<br />

blinds<br />

upper<br />

attached at<br />

awning<br />

top<br />

broken<br />

446b<br />

stacked good, some<br />

wood chipping, some<br />

awning moisture<br />

window with damage on<br />

muntins muntins<br />

good, vertical<br />

blinds<br />

attached at<br />

top<br />

excellent excellent yes no good east<br />

448a<br />

448b<br />

stacked good, some<br />

wood chipping, some<br />

awning moisture<br />

window with damage on<br />

muntins muntins<br />

stacked good, some<br />

wood chipping, some<br />

awning moisture<br />

window with damage on<br />

muntins muntins<br />

good, some<br />

signs of<br />

moisture<br />

damage<br />

good, some<br />

signs of<br />

moisture<br />

damage<br />

excellent excellent yes no fair east yes<br />

excellent excellent yes no fair east<br />

450a<br />

stacked good, some<br />

wood chipping, some<br />

awning moisture<br />

window with damage on<br />

muntins muntins<br />

good, some<br />

signs of<br />

moisture<br />

damage<br />

excellent excellent not<br />

accessible<br />

no good east<br />

450b<br />

stacked good, some<br />

wood chipping, some<br />

awning moisture<br />

window with damage on<br />

muntins muntins<br />

good, some<br />

signs of<br />

moisture<br />

damage<br />

excellent excellent not<br />

accessible<br />

no good east<br />

Straub Hall Window Condition Assessment - 65


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

452a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, vertical excellent excellent yes no excellent east<br />

blinds<br />

attached at<br />

top<br />

452b<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

good, vertical<br />

blinds<br />

attached at<br />

top<br />

excellent<br />

new pull on<br />

upper<br />

awning<br />

yes no excellent east<br />

453a<br />

453b<br />

454a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good, some<br />

signs of<br />

moisture<br />

damage<br />

excellent no lock yes no excellent west<br />

excellent excellent not<br />

accessible<br />

no good west<br />

excellent excellent yes no excellent east yes<br />

454b<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

excellent excellent excellent yes no excellent east<br />

Straub Hall Window Condition Assessment - 66


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

455a<br />

H455a<br />

456a<br />

457a<br />

457b<br />

458a<br />

double hung<br />

w/wood<br />

muntins<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Conditions<br />

Paint<br />

excellent<br />

interior, some<br />

chipping on<br />

exterior<br />

excellent, dark<br />

brown rather<br />

than salmon or<br />

white, exterior<br />

has some<br />

chipping<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

good, some<br />

chipping<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent, excellent excellent yes no excellent west<br />

with scars<br />

from lock<br />

hitting<br />

muntins<br />

excellent excellent excellent yes no excellent east yes<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, cracking<br />

in stool<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

excellent excellent yes no excellent east<br />

excellent excellent not<br />

accessible<br />

excellent<br />

both weight<br />

cords are<br />

broken<br />

no excellent west<br />

no no good west yes<br />

excellent excellent yes no good east<br />

Straub Hall Window Condition Assessment - 67


* All parts in excellent condition otherwise unless mentioned<br />

Window Window<br />

# T y p e<br />

459a<br />

470a<br />

470b<br />

double hung<br />

w/wood<br />

muntins<br />

Conditions<br />

Paint<br />

good, some<br />

chipping<br />

stacked good, some<br />

wood chipping on<br />

awning interior,<br />

window with extensive<br />

muntins chipping on<br />

exterior, with<br />

signs of past<br />

condensation<br />

accumulation<br />

stacked good, some<br />

wood chipping on<br />

awning interior,<br />

window with extensive<br />

muntins chipping on<br />

exterior, with<br />

signs of past<br />

condensation<br />

accumulation<br />

Window<br />

Parts*<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top, some<br />

splitting in<br />

casing<br />

good, some<br />

signs of<br />

moisture<br />

damage<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

Brick Sill<br />

Facing<br />

Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />

excellent excellent yes no good west<br />

excellent excellent yes no good east<br />

excellent excellent yes no excellent east<br />

S470a **see S370a** east<br />

471a<br />

H472a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

excellent excellent excellent not<br />

accessible<br />

no excellent west<br />

excellent excellent excellent yes no excellent east yes<br />

Straub Hall Window Condition Assessment - 68


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

473a<br />

474a<br />

double hung<br />

w/wood<br />

muntins<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

good, some<br />

chipping, some<br />

moisture<br />

damage on<br />

muntins<br />

Window<br />

Parts*<br />

good, minor<br />

splitting in<br />

case<br />

cracking/chi<br />

pping in<br />

exterior sash<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent yes no good west<br />

excellent excellent yes no good east<br />

474b<br />

stacked<br />

wood<br />

severe flaking<br />

seems to be<br />

cracking/chi<br />

pping in<br />

awning caused by water exterior sash<br />

window with /condensation<br />

muntins<br />

excellent excellent yes no good east yes<br />

475a<br />

476a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

stacked excellent<br />

wood interior, some<br />

awning chipping on<br />

window with exterior<br />

muntins<br />

excellent excellent excellent yes no excellent west<br />

excellent excellent excellent yes no excellent east<br />

(new chains)<br />

476b<br />

stacked excellent<br />

wood interior, some<br />

awning chipping on<br />

window with exterior<br />

muntins<br />

excellent,<br />

some<br />

cracking on<br />

exterior sash<br />

excellent excellent yes no excellent east<br />

477a<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good amount excellent excellent yes no good west yes<br />

of splitting in<br />

case<br />

Straub Hall Window Condition Assessment - 69


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

478a<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, lower 8 excellent excellent yes, sticky no good east restroom - wood panels yes<br />

panels have<br />

needed for privacy<br />

been painted<br />

white<br />

480a<br />

483a<br />

483b<br />

483c<br />

484a<br />

S484a<br />

485a<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

excellent<br />

interior, some<br />

chipping on<br />

exterior<br />

excellent<br />

excellent<br />

excellent<br />

interior, some<br />

chipping on<br />

exterior<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, minor<br />

splitting in<br />

case<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

excellent,<br />

horizontal<br />

blinds<br />

attached, a<br />

few dents<br />

excellent<br />

broken left<br />

weight cord<br />

not<br />

accessible<br />

excellent excellent not<br />

accessible<br />

no good west<br />

no excellent west<br />

excellent excellent yes no excellent west<br />

good, some<br />

moss<br />

accumulation<br />

good, some<br />

moss<br />

accumulation<br />

excellent yes no excellent south<br />

excellent yes no good south yes<br />

fair excellent excellent yes no good east scars from relpaced<br />

sections and lock<br />

damage seen on<br />

casement<br />

good, minor excellent excellent yes no good south<br />

splitting in<br />

case<br />

yes<br />

Straub Hall Window Condition Assessment - 70


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

487a<br />

488a<br />

double hung<br />

w/wood<br />

muntins<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

excellent<br />

Window<br />

Parts*<br />

chips and<br />

cracks in<br />

stool and<br />

lower<br />

muntins/sas<br />

h<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

excellent excellent yes no good south yes<br />

excellent excellent yes no excellent north<br />

488b<br />

stacked excellent<br />

wood<br />

awning<br />

window with<br />

muntins<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

good, minor<br />

moss<br />

accumulation<br />

excellent yes no excellent north<br />

489a<br />

H489a<br />

double hung<br />

w/wood<br />

muntins<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

major<br />

splitting in<br />

meeting rail<br />

excellent excellent good, some<br />

moss<br />

accumulation<br />

excellent excellent no no fair south yes<br />

excellent yes no excellent north yes<br />

490a<br />

stacked excellent<br />

wood<br />

awning<br />

window with<br />

muntins<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

excellent excellent yes no excellent north<br />

Straub Hall Window Condition Assessment - 71


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

490b<br />

491a<br />

stacked<br />

wood<br />

awning<br />

window with<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

excellent<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior, with<br />

signs of past<br />

condensation<br />

accumulation<br />

Window<br />

Parts*<br />

joined at the<br />

middle,<br />

opening at<br />

the right<br />

some<br />

splitting in<br />

case, also<br />

signs of past<br />

condensation<br />

accumulation<br />

on the lower<br />

muntins<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

excellent slider and<br />

new lock at<br />

middle right<br />

Facing<br />

Elev. Comments Photo<br />

yes<br />

yes no good/fair north this window was<br />

originally a stacked<br />

awning configuration,<br />

and has been sealed at<br />

the meeting to now<br />

operate as a casement<br />

window<br />

excellent excellent yes no good south yes<br />

492a<br />

stacked good, some<br />

wood chipping<br />

awning<br />

window with<br />

muntins<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

excellent excellent yes no excellent north<br />

492b<br />

stacked excellent<br />

wood<br />

awning<br />

window with<br />

muntins<br />

good,<br />

horizontal<br />

blinds<br />

attached at<br />

top<br />

excellent excellent yes no excellent north<br />

Straub Hall Window Condition Assessment - 72


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

493a<br />

double hung<br />

w/wood<br />

muntins<br />

Paint<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior, with<br />

signs of past<br />

condensation<br />

accumulation<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

some excellent excellent yes no good south<br />

splitting in<br />

case, also<br />

signs of past<br />

condensation<br />

accumulation<br />

on the lower<br />

muntins<br />

494a<br />

497a<br />

497b<br />

497c<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

double hung<br />

w/wood<br />

muntins<br />

good, some<br />

chipping<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

good, some<br />

chipping on<br />

interior,<br />

extensive<br />

chipping on<br />

exterior<br />

all panels<br />

painted<br />

white, urinal<br />

attached to<br />

case at lower<br />

right<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

not accessible<br />

excellent<br />

wood blocks<br />

around<br />

weight<br />

cords, right<br />

weight cord<br />

broken<br />

missing lock,<br />

broken left<br />

weight cord<br />

top window<br />

sits on<br />

exterior<br />

supports for<br />

ventilation,<br />

bottom is<br />

fixed<br />

not<br />

accessibl<br />

e<br />

no no good south<br />

excellent excellent yes no excellent south<br />

good, minor<br />

moss<br />

accumulation<br />

broken lach<br />

for lock<br />

yes no excellent east<br />

fair north yes<br />

Straub Hall Window Condition Assessment - 73


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e Paint<br />

498a double hung good, some<br />

w/wood chipping on<br />

muntins interior,<br />

extensive<br />

chipping on<br />

exterior<br />

498b double hung good, some<br />

w/wood chipping on<br />

muntins interior,<br />

extensive<br />

chipping on<br />

exterior<br />

S498a **see S398a**<br />

Window<br />

Parts*<br />

excellent,<br />

horizontal<br />

blinds<br />

attached<br />

splitting in<br />

case<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

Facing<br />

Elev. Comments Photo<br />

good, minor excellent yes no good east<br />

moss<br />

accumulation<br />

excellent excellent not<br />

accessible<br />

no good north<br />

Sky1<br />

Sky2<br />

Skylight<br />

domed<br />

Skylight<br />

domed<br />

lots of flaking<br />

on interior<br />

fair NA none no not able<br />

to<br />

thorough<br />

ly assess<br />

good<br />

excellent fair NA none no not able<br />

to<br />

thorough<br />

ly assess<br />

excellent<br />

peeling interior paint yes<br />

indicates possible water<br />

infiltration or<br />

condensation<br />

accumulation. Opening<br />

covered on interior with<br />

vent and dropped<br />

ceiling.<br />

Sky3<br />

Skylight<br />

straight gable<br />

excellent fair NA none no not able<br />

to<br />

thorough<br />

ly assess<br />

good<br />

some mildew at joints,<br />

sealant compromised<br />

Sky4<br />

Skylight<br />

domed<br />

excellent fair NA none no not able<br />

to<br />

thorough<br />

ly assess<br />

excellent<br />

Straub Hall Window Condition Assessment - 74


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

Sky5 Skylight<br />

domed<br />

Paint<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

excellent fair NA none no not able excellent<br />

to<br />

thorough<br />

ly assess<br />

Facing<br />

Elev. Comments Photo<br />

Sky6<br />

Skylight<br />

domed<br />

excellent fair NA none no not able<br />

to<br />

thorough<br />

ly assess<br />

excellent<br />

Sky7<br />

Skylight<br />

straight gable<br />

excellent fair NA none no not able<br />

to<br />

thorough<br />

ly assess<br />

fair to poor<br />

large amount of mildew<br />

at joints, sealant<br />

compromised<br />

yes<br />

Sky8<br />

Skylight<br />

domed<br />

excellent fair NA none no not able<br />

to<br />

thorough<br />

ly assess<br />

excellent<br />

Sky9<br />

Sky10<br />

Skylight<br />

domed<br />

Skylight<br />

domed<br />

lots of flaking<br />

on interior<br />

fair NA none no not able<br />

to<br />

thorough<br />

ly assess<br />

good<br />

excellent fair NA none no not able<br />

to<br />

thorough<br />

ly assess<br />

excellent<br />

peeling interior paint<br />

indicates possible water<br />

infiltration or<br />

condensation<br />

accumulation. Opening<br />

enclosed by dropped<br />

ceiling.<br />

yes<br />

Sky11<br />

Skylight<br />

domed<br />

excellent fair NA none no not able<br />

to<br />

thorough<br />

ly assess<br />

good<br />

peeling interior paint<br />

indicates possible water<br />

infiltration or<br />

condensation<br />

accumulation.<br />

Straub Hall Window Condition Assessment - 75


* All parts in excellent condition otherwise unless mentioned<br />

Conditions<br />

Window Window<br />

# T y p e<br />

Sky12 Skylight<br />

domed<br />

Paint<br />

lots of flaking<br />

on interior<br />

Window<br />

Parts*<br />

Brick Sill<br />

Condition Hardware Operability Dry Rot Overall<br />

fair NA none no not able excellent<br />

to<br />

thorough<br />

ly assess<br />

Facing<br />

Elev. Comments Photo<br />

peeling interior paint<br />

indicates possible water<br />

infiltration or<br />

condensation<br />

accumulation.<br />

Straub Hall Window Condition Assessment - 76


30Ab ^<br />

28Aa ^<br />

B<br />

30Aa ^<br />

Straub Hall Window Condition Assessment - 77


178c ^<br />

^ 152Ba<br />

170a ><br />

1 Straub Hall Window Condition Assessment - 78


^ 202b<br />

^ 274a<br />

^ 204b<br />

^ S290a<br />

^ 208a<br />

2<br />

^ 204a<br />

Straub Hall Window Condition Assessment - 79


^ 304a<br />

^ 310b<br />

^ H331a<br />

< 344b<br />

308a ><br />

3 Straub Hall Window Condition Assessment - 80


^ 404a<br />

413a ^<br />

4<br />

426a ><br />

Straub Hall Window Condition Assessment - 81


^ Sky #7<br />

Sky #1 ^<br />

^ Sky #7 ^ Sky #7 Sky #1 ^<br />

R<br />

Straub Hall Window Condition Assessment - 82


051b<br />

051a<br />

030Aa X<br />

030Ab X<br />

028a<br />

028b<br />

028c<br />

025a<br />

Straub Hall Window Condition Assessment - 83


109c 109b 109a<br />

156Dd 156Db<br />

156Dc<br />

199Aa<br />

199b<br />

111a<br />

111b<br />

113a<br />

119b<br />

119c<br />

122a<br />

122b<br />

122c<br />

109d<br />

109e<br />

122d<br />

105a<br />

S113a<br />

119a<br />

126a<br />

S120a<br />

129a<br />

127a<br />

131a 131b<br />

168Ca<br />

168Cb<br />

142c<br />

142d<br />

128a 130a S130a<br />

142a<br />

142b<br />

137a<br />

139a<br />

139b<br />

146b<br />

141a<br />

140a<br />

146a<br />

155b<br />

155a<br />

154a<br />

S170a<br />

156Da<br />

156Ba<br />

178Aa<br />

178a<br />

199Ab<br />

152Aa<br />

152Ba<br />

153a 170a 172a 178b 178c 180b 180c<br />

S198a<br />

196a<br />

195a<br />

193a<br />

191a<br />

180a<br />

186a<br />

199a<br />

194a<br />

189b<br />

189a<br />

186b<br />

Straub Hall Window Condition Assessment - 84


Straub Hall Window Condition Assessment - 85<br />

L150c<br />

L150a<br />

L150b<br />

283b<br />

253a<br />

251a<br />

255a<br />

257a<br />

271a<br />

273a<br />

279b<br />

279a<br />

283a<br />

243a<br />

229a<br />

231a<br />

233a<br />

237a 239a 241a<br />

245a<br />

227a<br />

209a<br />

211a<br />

212a<br />

220a<br />

221a<br />

221b<br />

207a<br />

205a<br />

202a<br />

208a<br />

S230a<br />

230a<br />

228a<br />

228b<br />

224a<br />

210d<br />

210c<br />

210b<br />

210a<br />

S210a<br />

298a<br />

S290a<br />

294a<br />

292a<br />

292b<br />

290a<br />

290b<br />

S284a<br />

278b 278a<br />

272a<br />

272b<br />

270a<br />

270b<br />

S270a<br />

298b<br />

287a<br />

293a<br />

295c<br />

295b<br />

295a<br />

259a<br />

235a<br />

225a<br />

H219a<br />

226a<br />

226b<br />

232a<br />

232b<br />

H236a<br />

238a<br />

240a<br />

240b<br />

242a<br />

242b<br />

252a<br />

254a<br />

256a<br />

258a<br />

274a<br />

H286a<br />

H286b<br />

H286c<br />

288a<br />

289a<br />

291a<br />

H202a<br />

204b<br />

204a<br />

203a<br />

201a<br />

201b<br />

223a<br />

284a<br />

284b


309a<br />

311a<br />

312a<br />

320a<br />

321a<br />

301a<br />

301b<br />

303a<br />

305a<br />

307a<br />

321b<br />

302b<br />

310d<br />

310c<br />

310b<br />

310a<br />

323a<br />

302a<br />

H302a<br />

304b<br />

304a<br />

308a<br />

S310a<br />

H319<br />

325a<br />

324a<br />

327a<br />

326a<br />

326b<br />

328a<br />

328b<br />

329a<br />

H331a<br />

331a<br />

332a<br />

332b<br />

333a<br />

S330a<br />

335a<br />

H336a<br />

338a<br />

337a 337b339a<br />

H340a<br />

342a<br />

342b<br />

341a<br />

344a<br />

344b<br />

343a<br />

346a<br />

346b<br />

345a<br />

348a 352a<br />

348b 352b<br />

350a<br />

350b 354a<br />

347a<br />

349a<br />

351a 353a<br />

356a<br />

355a<br />

358a<br />

357a<br />

S370a<br />

359a<br />

370a<br />

370b<br />

371a<br />

H372a<br />

373a<br />

380c 380a<br />

380d 380b382a<br />

375a<br />

377a<br />

398b<br />

398a<br />

S384a<br />

381a<br />

S398a<br />

394a<br />

392a<br />

392b<br />

H389a<br />

390a<br />

390b<br />

388a<br />

388b<br />

397a<br />

383a 385a<br />

386a<br />

385b<br />

397b<br />

395a<br />

393a<br />

391a<br />

389a<br />

387Aa<br />

387a<br />

Straub Hall Window Condition Assessment - 86


401Ac<br />

401Ad<br />

409a<br />

411a<br />

413a<br />

419a<br />

401b<br />

405a<br />

407a<br />

401Ab<br />

408d<br />

408c<br />

408b<br />

408a<br />

401Aa<br />

401a<br />

H402a<br />

404b<br />

404a<br />

406a<br />

S410a<br />

422a 426a<br />

426b<br />

424a<br />

H419a 424b H427a<br />

428a<br />

428b<br />

S430a<br />

H432a<br />

H442a 446a<br />

446b<br />

450a<br />

450b<br />

454a<br />

454b<br />

444a<br />

444b<br />

448a<br />

448b<br />

452a<br />

452b H455a<br />

498b<br />

S498a<br />

494a<br />

492a<br />

492b<br />

H489a<br />

H472a<br />

490a<br />

490b<br />

456a S470a 474a 476a 478a488a<br />

488b<br />

458a<br />

470a<br />

470b 474b 476b S484a<br />

498a<br />

497c<br />

497b<br />

497a<br />

493a<br />

491a<br />

489a<br />

487a<br />

485a<br />

484a<br />

420a<br />

420b<br />

420c<br />

423a<br />

425b 429a<br />

425a 427a<br />

431a<br />

433a 435a 441a<br />

443a<br />

443b<br />

445a<br />

451a<br />

453a<br />

457a<br />

459a<br />

453b 455a 457b<br />

471a<br />

473a<br />

475a<br />

477a<br />

480a<br />

483a 483b<br />

483c<br />

Straub Hall Window Condition Assessment - 87


Sky1<br />

Sky12<br />

Sky11<br />

Sky9<br />

Sky10<br />

Sky2<br />

Sky8<br />

Sky3<br />

Sky7<br />

Sky4 Sky5 Sky6<br />

Straub Hall Window Condition Assessment - 88


UO Straub Hall - Deferred Maintenance and Seismic Upgrade 1 of 3<br />

PART 1 - GENERAL<br />

1.01 SUMMARY<br />

SECTION 06 6100<br />

ARCHITECTURAL FIBERGLASS<br />

A. Section Includes:<br />

1. Fabrication of fiberglass - reinforced polyester replicas of existing masonry chimneys.<br />

B. Related Documents and Sections:<br />

1. General Conditions, Supplementary Conditions and Division 1 General Requirements apply<br />

to the work of this section.<br />

2. Section 06 1000, “Rough Carpentry”, for support frame and blocking.<br />

3. Section 07 6200, “Sheet Metal Flashing and Trim”.<br />

4. Section 07 9005, “Joint Sealants”.<br />

1.02 QUALITY ASSURANCE<br />

A. The fiberglass manufacturer shall be one who is currently in the business of manufacturing and<br />

supplying architectural fiberglass components for the building construction industry and who can<br />

demonstrate the capability.<br />

B. The fiberglass manufacturer shall have been engaged in the fiberglass industry for at least 10<br />

years doing work with projects comparable in size, scope, detail, and complexity to that shown<br />

and specified.<br />

1. Submit a list of comparable projects, locations, and owner contacts with bid documents.<br />

C. Single Source Responsibility for Architectural Fiberglass: Obtain architectural fiberglass from a<br />

single source with resources to provide products complying with requirements indicated without<br />

delaying the work.<br />

D. Fire Test Response Characteristics: Provide architectural fiberglass and related materials with<br />

fire test response characteristics as specified elsewhere in this section as determined by testing<br />

identical products per test method ASTM E-84 or other testing and inspecting agency<br />

acceptable to authorities having jurisdiction. Provide written certification that supplied<br />

architectural fiberglass panels meets or exceeds the criteria.<br />

1.03 1.03 SUBMITTALS<br />

A. Qualification Data for firms and persons specified in the “Quality Assurance” Article to<br />

demonstrate their capabilities and experience. Include lists of completed projects with project<br />

names and addresses, names and addresses of architects and owners, and other information<br />

specified.<br />

B. Color Selection:<br />

1. Submit custom color sample selection chips of actual material showing color, texture and<br />

sheen available for initial review.<br />

a. Custom paint color samples to be based on existing masonry chimneys.<br />

C. Shop Drawings:<br />

1. Submit shop drawings for fabrication and erection. Include plans, elevations, sections,<br />

profiles, and details of Chimney reproductions. Indicate dimensions of each profile and<br />

component. Include for comparison a dimensioned drawing showing plan elevation<br />

section and details of existing Chimney used for model purposes if applicable. Indicate<br />

those features, which differ from fiberglass replication. Include details for connections,<br />

anchorage to substructure and all miscellaneous accessories. Show all special<br />

fabrications.<br />

D. Samples:<br />

1. Submit sample Chimney corner section, minimum 18” high by 12” in each plan direction<br />

including step in existing Chimney profile. Construct sample panel to show connection<br />

points, embedded connection and reinforcing clips, include typical fasteners to complete<br />

the submission.<br />

<strong>Addendum</strong> B 06 6100<br />

May 24, 2013<br />

ARCHITECTURAL FIBERGLASS


UO Straub Hall - Deferred Maintenance and Seismic Upgrade 2 of 3<br />

E. Submit detailed maintenance instructions for inclusion in final operation and maintenance<br />

manuals.<br />

F. Submit warranty on completed fiberglass components in writing against defects of materials and<br />

workmanship and to meet the specified requirements of this Section for a period of one (1) year<br />

from delivery to site.<br />

1.04 HANDLING AND SHIPMENT<br />

A. Provide shipping crates of sufficient size and strength to protect components during shipping or<br />

ship fiberglass components in padded dedicated moving van.<br />

1. Provide additional protection as may be necessary to prevent soiling of surfaces and<br />

marring of finish.<br />

PART 2 - PRODUCTS<br />

2.01 ACCEPTABLE MANUFACTURES<br />

A. Subject to compliance with requirements, fiberglass manufacturer offering products that may be<br />

incorporated in work include:<br />

1. Architectural Reproductions; www.archrepro.com . Portland,<br />

OR, PH: 888-440-8007<br />

2. Approved equal.<br />

2.02 MATERIALS<br />

A. General: The fiberglass reinforced polyester plastic components shall be designed, fabricated<br />

and erected to conform to the state of <strong>Oregon</strong> Building Code, Local Codes and to the Architect’s<br />

design criteria.<br />

B. Glass cloth, matt and “Chop” shall be equal to the products of PPG-Owens Corning.<br />

C. The resin shall be flame retardant, promoted thixotropic polyester resin designed for use in<br />

hand laid up and spraying processes. The resin shall be specifically formulated for use in<br />

applications that require an ASTM E 84, Class I flame spread rating, without the use of fillers or<br />

antimony trioxide, with an ASTM E 84 flame spread rating of 25 unfilled smoke density of 380 or<br />

under.<br />

D. Gel Coat: The gel coat shall be a high-performance product with ultraviolet inhibitors as<br />

recommended by the gel coat and fiberglass panel manufacturer. Acceptable products are:<br />

1. IMC” by Cook Composites and Polymers Co., P. o. Box 419389, Kansas City, MO<br />

64141-6389, (816) 391-6000.<br />

2. Series by Neste Polyester Inc., 5106 Wheeler Avenue, Fort Smith, AK 72901, (501)<br />

646-7865<br />

3. Shield-NPG” by Ferro Corporation, One Erieview Plaza, Cleveland OH 44114, (216)<br />

641-8580<br />

4. Approved equal.<br />

E. Catalyzed Polyurethane: The catalyzed polyurethane shall be a high-performance product with<br />

ultraviolet inhibitors as recommended by the fiberglass panel manufacturer. Acceptable<br />

manufacturers are:<br />

1. Tnemec; www.tnemec.com <br />

2. Approved equal<br />

F. Fiberglass-reinforced polyester components shall be manufactured using the specified resins,<br />

reinforced with chopped glass fibers. All exposed surfaces shall be finished with custom<br />

colored gel-coat and catalyzed polyurethane.<br />

G. Internal metal reinforcement, anchorage clips, brackets and all other “built-in” accessories shall<br />

be captured and additionally reinforced with additional glass fiber and matt of sufficient<br />

thickness as required by the panel manufacturers design.<br />

H. All metal hardware, both loose and embedded, shall be stainless steel.<br />

I. Gel coat thickness shall be 0.015” minimum to 0.025” maximum.<br />

100% <strong>Addendum</strong> CONSTRUCTION B<br />

DOCUMENTS 06 6100<br />

April May 19, 24, 2013<br />

ARCHITECTURAL FIBERGLASS


UO Straub Hall - Deferred Maintenance and Seismic Upgrade 3 of 3<br />

J. Panel thickness shall be 3/16” minimum.<br />

2.03 PANEL FABRICATION<br />

A. Prior to commencement of work review the job site before selective demolition begins to<br />

determine the layout, masonry coursings and dimensions of the existing chimneys. Duplicate<br />

these layouts, masonry coursings and dimensions in so far as practical. Identify and resolve<br />

panel detail conflicts in advance and identify such condition and resolutions on the shop<br />

drawings.<br />

B. Carefully measure each existing chimney assembly component and replicate size, profile,<br />

position, and detail in the finished panel so far as practical. Indicate on shop drawings those<br />

indentations and/or detail which cannot be duplicated in the replication due to physical<br />

limitations of the manufacturing process.<br />

C. Full-size models and mock-ups shall be hand carved and machined as required to produce the<br />

replication patterns.<br />

D. Production molds shall be constructed from successive layers of glass fiber with tooling gel coat<br />

or alternately from rubber molds. Molds shall be constructed with sufficient thickness and<br />

rigidity to prevent deflection, warpage and defects during panel production.<br />

E. Provide all special transition piecesand special closures necessary for a complete, visually<br />

continuous, weather tight installation.<br />

F. Coordinate cutouts required for penetrations. Reinforce panel as required and provide special<br />

formed closures to make joints and intersection weather tight.<br />

PART 3 - EXECUTION<br />

3.01 INSTALLATION<br />

A. Coordinate required blocking for attachment of chimney reproductions to substructure. Provide<br />

additional, wood preservative treated or metal stud framing as may be required to attached and<br />

reinforce cornice panels for a solid installation.<br />

1. Coordinate installation with sheet metal flashing work.<br />

B. Erect reproduction chimneys plumb, square and true to line and level. Follow fiberglass<br />

reproduction manufacturer’s recommendations with regard to installation clearances, notches,<br />

and terminations.<br />

C. Install sealant and accessories as work progresses, so as to make the work weather tight.<br />

D. Prepare each chimney reproduction for installation by carefully sanding joints and shrinkages<br />

where blocking occurs to assure tight and flush fit.<br />

E. Fill joints with a continuous bead of sealant. Tooling finished joints to a slightly concave profile<br />

ensuring complete filling and flush installation.<br />

F. Carefully monitor ambient temperatures at time of panel installation and observe all panels to<br />

panel clearances recommended by the fiberglass manufacturer.<br />

G. Do not cut or abrade finishes, which cannot be completely restored in the field. Installer to<br />

make small inconspicuous repairs using manufactures color matching gel fill finish.<br />

H. Use only stainless steel connectors approved by the panel manufacturer. The installer shall<br />

supply these connectors.<br />

I. Countersink all exposed fasteners. Patch all attachment holes with gel fill finish supplied by the<br />

fiberglass panel manufacturer for field application. Finish attachment points so that there is no<br />

detectable difference in the completed panel surface.<br />

J. Clean installed panel to remove all dirt, smudges, and construction dirt. Use only those<br />

cleaning products and procedures recommended by the fiberglass manufacturer.<br />

END OF SECTION<br />

100% <strong>Addendum</strong> CONSTRUCTION B<br />

DOCUMENTS 06 6100<br />

April May 24, 19, 2013<br />

ARCHITECTURAL FIBERGLASS


UO Straub Hall - Deferred Maintenance and Seismic Upgrade 1 of 3<br />

PART 1 GENERAL<br />

1.01 SECTION INCLUDES<br />

SECTION 08 1116<br />

ALUMINUM DOORS AND FRAMES<br />

A. Aluminum door frames for doors specified elsewhere.<br />

B. Glazing.<br />

1.02 RELATED REQUIREMENTS<br />

A. Section 08 1433 – Stile and Rail Wood Doors: Glazed wood doors.<br />

B. Section 08 7100 - Door Hardware: Hardware for aluminum doors.<br />

C.. Section 08 8000 - Glazing: Glazing materials for aluminum doors and frames.<br />

1.03 REFERENCE STANDARDS<br />

A. AAMA 609 - Voluntary Guide Specification for Cleaning and Maintenance of Architectural<br />

Anodized Aluminum; American Architectural Manufacturers Association; 2009.<br />

B. AAMA 611 - Voluntary Specification for Anodized Architectural Aluminum; American<br />

Architectural Manufacturers Association; 2012.<br />

C. AAMA 701/702 - Voluntary Specifications for Pile Weatherstripping and Replaceable<br />

Fenestration Weatherseals; American Architectural Manufacturers Association; 2011.<br />

D. AAMA 2603 - Voluntary Specification, Performance Requirements and Test Procedures for<br />

Pigmented Organic Coatings on Aluminum Extrusions and Panels; American Architectural<br />

Manufacturers Association; 2002.<br />

E. ASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron<br />

and Steel Products; 2012.<br />

F. ASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate; 2010.<br />

G. ASTM B209M - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate<br />

[Metric]; 2010.<br />

H. ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods,<br />

Wire, Profiles, and Tubes; 2012.<br />

I. ASTM B221M - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods,<br />

Wire, Profiles, and Tubes [Metric]; 2012.<br />

1.04 SUBMITTALS<br />

A. See Section 01 3000 - Administrative Requirements, for submittal procedures.<br />

B. Shop Drawings: Include elevations of each opening type.<br />

1. Verify dimensions by field measurements before fabrication and indicate on shop<br />

drawings.<br />

C. Selection Samples: Complete set of color and finish options, using actual materials, for<br />

Architect's selection.<br />

D. Warranty: Submit manufacturer warranty and ensure that forms have been completed in<br />

Owner's name and registered with manufacturer.<br />

1.05 QUALITY ASSURANCE<br />

A. Manufacturer Qualifications: Not less than 5 years of experience in manufacturing components<br />

of the types specified.<br />

B. Installer Qualifications: Firm with documented experience in installing components of the types<br />

specified.<br />

<strong>Addendum</strong> B 08 1116<br />

May 24, 2013<br />

ALUMINUM DOORS AND FRAMES


UO Straub Hall - Deferred Maintenance and Seismic Upgrade 2 of 3<br />

1.06 DELIVERY, STORAGE, AND HANDLING<br />

A. Deliver aluminum components in manufacturer's standard protective packaging, palleted,<br />

crated, or banded together.<br />

B. Inspect delivered components for damage and replace. Repaired components will not be<br />

accepted.<br />

C. Store components under cover in manufacturer's packaging until installation.<br />

1.07 FIELD CONDITIONS<br />

A. Do not begin installation of interior aluminum components until space has been enclosed and<br />

ambient thermal conditions are being maintained at levels consistent with final project<br />

requirements.<br />

PART 2 PRODUCTS<br />

2.01 MANUFACTURERS<br />

A. Glazed Interior Aluminum Door Frames:<br />

1. Wilson Partitions: www.wilsonpart.com.<br />

2. Approved Equal.<br />

3. Substitutions: See Section 01 6000 - Product Requirements.<br />

2.02 DOORS AND FRAMES<br />

A. Door, Sidelight, and Transom Frames: Extruded aluminum hollow or C-shaped sections; no<br />

steel components.<br />

1. Finish: Pigmented coating, manufacturer's standard type.<br />

2. Weatherstripping: Replaceable pile type; at jambs and head.<br />

2.03 COMPONENTS<br />

A. Frames: Extruded aluminum shapes, not less than 0.062 inch thick, reinforced at hinge and<br />

strike locations.<br />

1. Corner Brackets: Extruded aluminum, fastened with stainless steel screws.<br />

2. Trim: Extruded aluminum, not less than 0.062 inch thick, removable snap-in type without<br />

exposed fasteners.<br />

2.04 MATERIALS<br />

A. Aluminum Sheet: ASTM B209 (ASTM B209M), alloy 5005-H14, stretcher leveled.<br />

B. Extruded Aluminum: ASTM B221 (ASTM B221M), alloy 6063-T5 or alloy 6463-T5.<br />

C. Natural Anodized Finish: Clear anodic coating; AAMA 611 AA-M12C22A31 Class II, minimum<br />

thickness 0.4 mil.<br />

D. Coated Finish: Pigmented organic coating of not less than 0.8 mils thickness, conforming to<br />

requirements of AAMA 2603; color as selected from manufacturer's full range by Architect.<br />

E. Aluminum Sheet: ASTM B209 (ASTM B209M), alloy 5005-H14, stretcher leveled.<br />

F. Extruded Aluminum: ASTM B221 (ASTM B221M), alloy 6063-T5 or alloy 6463-T5.<br />

G. Tubular Aluminum Doors: Provide 1-3/4 in thick glazed doors using materials as follows:<br />

H. Aluminum Door Frames: Provide frames sized to fit wall thicknesses indicated on the drawings,<br />

in profiles indicated, and constructed from materials as follows:<br />

I. Finish: High Performance Organic Coating: Kynar/Polyvinylidene Fluoride (PVDF) complying<br />

with requirements of AAMA 2604; color as selected from manufacturer's full range by Architect.<br />

2.05 ACCESSORIES<br />

A. Replaceable Weatherstripping: AAMA 701/702 wool pile.<br />

B. Fasteners: Aluminum, non-magnetic stainless steel, or other material warranted by<br />

manufacturer as non-corrosive and compatible with aluminum components.<br />

100% CONSTRUCTION DOCUMENTS 08 1116<br />

April 19, 2013<br />

ALUMINUM DOORS AND FRAMES


UO Straub Hall - Deferred Maintenance and Seismic Upgrade 3 of 3<br />

C. Brackets and Reinforcements: Manufacturer's high-strength aluminum units where feasible,<br />

otherwise, non-magnetic stainless steel or steel hot-dip galvanized in compliance with ASTM<br />

A123/A123M.<br />

D. Bituminous Coating: Cold-applied asphaltic mastic, compounded for 30-mil thickness per coat.<br />

PART 3 EXECUTION<br />

3.01 PREPARATION<br />

A. Perform cutting, fitting, forming, drilling, and grinding of frames as required for project<br />

conditions.<br />

B. Replace components with damage to exposed finishes.<br />

C. Separate dissimilar metals to prevent electrolytic action between metals.<br />

3.02 INSTALLATION<br />

A. Install doors and frames in accordance with manufacturer's instructions and approved shop<br />

drawings.<br />

B. Set frames plumb, square, level, and aligned to receive doors. Anchor frames to adjacent<br />

construction in strict accordance with manufacturer's recommendations and within specified<br />

tolerances.<br />

C. Where aluminum surfaces contact metals other than stainless steel, zinc, or small areas of<br />

white bronze, protect from direct contact by painting dissimilar metal with heavy coating of<br />

bituminous paint.<br />

D. Hang doors and adjust hardware to achieve specified clearances and proper door operation.<br />

E. Install door hardware as specified in Section 08 7100.<br />

3.03 CLEANING<br />

A. Upon completion of installation, thoroughly clean frame surfaces in accordance with AAMA<br />

609.<br />

B. Do not use abrasive, caustic, or acid cleaning agents.<br />

3.04 PROTECTION<br />

A. Protect products of this section from damage caused by subsequent construction until<br />

substantial completion.<br />

B. Replace damaged or defective components that cannot be repaired to a condition<br />

indistinguishable from undamaged components.<br />

END OF SECTION<br />

100% CONSTRUCTION DOCUMENTS 08 1116<br />

April 19, 2013<br />

ALUMINUM DOORS AND FRAMES


Door/Hardware Index<br />

No Area<br />

Door # HWSet #<br />

001-1 01<br />

001-1E 43<br />

001-2 02<br />

001-3 02<br />

001-4 02<br />

001-5 03<br />

001-6 08<br />

002-1 04<br />

003-1 05<br />

004-1 05<br />

004-2 04<br />

005-1 05<br />

006-1 04<br />

007-1 04<br />

008-1 04<br />

008-2 05<br />

009-1 04<br />

010-1 04<br />

011-1 04<br />

012-1 04<br />

013-1 04<br />

014-1 04<br />

015-1 04<br />

016-1 04<br />

017-1 04<br />

018-1 04<br />

020-1 02<br />

020-2 02<br />

020-3 05<br />

021-1 48<br />

021-2 06<br />

024-1 07<br />

024-2 08<br />

025-1 07<br />

026-1 09<br />

026-2 43<br />

026-3 43<br />

027-1 10<br />

027-2 43<br />

028-1 08<br />

Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />

2013 2:28PM EDT<br />

Supplier: Ingersoll Rand Security<br />

Technologies<br />

Revision #: 4 Rev Date: May 14 2013<br />

11:28AM EDT<br />

Page 1 of 10


Door # HWSet #<br />

031-1 11<br />

031-2<br />

031-3 12<br />

031-4 43<br />

031-5 11<br />

032-1 05<br />

033-1 02<br />

034-1 13<br />

035-1 14<br />

036-1 11<br />

037-1 04<br />

038-1 04<br />

038-2 04<br />

039-1 02<br />

040-1 05<br />

040-2 15<br />

040-3 16<br />

041-1 02<br />

042-1 05<br />

043-1 17<br />

044-1 05<br />

046-1 05<br />

048-1 05<br />

051-1 14<br />

051-2 05<br />

051-3 18<br />

051-4 04<br />

051-5 07<br />

070-1 06<br />

100-1 07<br />

101-1 05<br />

102-1 05<br />

103-1 11<br />

104-1 11<br />

105-1 11<br />

106-1 05<br />

107-1 11<br />

107-2 19<br />

108-1 05<br />

109-1 05<br />

110-1 11<br />

110-2 49<br />

110-3 41<br />

Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />

2013 2:28PM EDT<br />

Supplier: Ingersoll Rand Security<br />

Technologies<br />

Revision #: 4 Rev Date: May 14 2013<br />

11:28AM EDT<br />

Page 2 of 10


Door # HWSet #<br />

110-4 02<br />

111-1 05<br />

112-1 04<br />

112-2 50<br />

112-3 19<br />

115-1 22<br />

120-1 07<br />

120-2 20<br />

120-3 23<br />

121-1 24<br />

122-2 24<br />

122-3 27<br />

123-1 05<br />

124-1 09<br />

125-1 11<br />

126-1 26<br />

127-1 11<br />

128-1 11<br />

129-1 11<br />

130-1 42<br />

130-1S 29<br />

130-3 30<br />

130-4 31<br />

131-1 11<br />

131-2 20<br />

132-1 11<br />

133-1 11<br />

137-1 11<br />

138-1 23<br />

138-2 32<br />

139-1 11<br />

141-1 02<br />

142-1 04<br />

142-2 04<br />

142-3 04<br />

143-1 04<br />

143-2 04<br />

144-1 02<br />

145-1 04<br />

146-1 04<br />

146-2 04<br />

146-3 04<br />

146-4 02<br />

Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />

2013 2:28PM EDT<br />

Supplier: Ingersoll Rand Security<br />

Technologies<br />

Revision #: 4 Rev Date: May 14 2013<br />

11:28AM EDT<br />

Page 3 of 10


Door # HWSet #<br />

147-1 15<br />

149-1 02<br />

150-1 34<br />

150-2 35<br />

150-3 35<br />

150-4 02<br />

152-1 23<br />

152-2 23<br />

154-1 04<br />

154-2 04<br />

154-3 04<br />

154-4 04<br />

156-1 04<br />

156-2 04<br />

161-1 11<br />

161-2 14<br />

161-3 37<br />

162-1 17<br />

166-1 11<br />

167-1 14<br />

167-2 02<br />

168-1 14<br />

168-2 14<br />

168-3 14<br />

168-4 38<br />

168-5 25<br />

168-6 25<br />

170-1 39<br />

170-1S 29<br />

170-2 31<br />

170-3 32<br />

172-1 11<br />

172-2 44<br />

173-1 11<br />

174-1 28<br />

177-1 11<br />

178-1 26<br />

179-1 11<br />

179-2 14<br />

180-1 11<br />

180-2 27<br />

181-1 11<br />

182-1 09<br />

Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />

2013 2:28PM EDT<br />

Supplier: Ingersoll Rand Security<br />

Technologies<br />

Revision #: 4 Rev Date: May 14 2013<br />

11:28AM EDT<br />

Page 4 of 10


Door # HWSet #<br />

183-1 05<br />

184-1 40<br />

184-2 27<br />

186-1 24<br />

187-1 05<br />

187-2 05<br />

187-3 14<br />

188-1 24<br />

189-1 08<br />

189A-1 11<br />

190-1 11<br />

190-2 27<br />

190-3 50<br />

190-4 49<br />

190-5 37<br />

191-1 11<br />

192-1 11<br />

193-1 11<br />

194-1 11<br />

195-1 11<br />

196-1 11<br />

197-1 11<br />

198-1 18<br />

199-1 26<br />

201-1 18<br />

202-1 11<br />

202-2 01<br />

202-3 02<br />

203-1 11<br />

204-1 11<br />

205-1 11<br />

206-1 11<br />

207-1 11<br />

208-1 24<br />

209-1 11<br />

210-1 45<br />

210-2 11<br />

211-1 11<br />

220-1 11<br />

221-1 11<br />

222-1 11<br />

223-1 11<br />

224-1 10<br />

Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />

2013 2:28PM EDT<br />

Supplier: Ingersoll Rand Security<br />

Technologies<br />

Revision #: 4 Rev Date: May 14 2013<br />

11:28AM EDT<br />

Page 5 of 10


Door # HWSet #<br />

225-1 11<br />

226-1~ 26<br />

227-1 11<br />

228-1 26<br />

229-1 11<br />

230-1 42<br />

230-2 27<br />

230-3 06<br />

231-1 11<br />

232-1 11<br />

233-1 11<br />

234-1 11<br />

235-1 11<br />

236-1 02<br />

237-1 11<br />

239-1 11<br />

250-1 11<br />

251-1 11<br />

251-2 11<br />

252-1 11<br />

253-1 11<br />

255-1 11<br />

266-1 11<br />

267-1 11<br />

267-2 27<br />

269-1 11<br />

270-1 26<br />

270-2 06<br />

271-1 11<br />

273-1 11<br />

274-1 26<br />

275-1 11<br />

276-1 09<br />

277-1 11<br />

277-2 27<br />

278-1 11<br />

279-1 11<br />

280-1 11<br />

280-2 01<br />

280-3 27<br />

281-1 11<br />

282-1 11<br />

283-1 11<br />

Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />

2013 2:28PM EDT<br />

Supplier: Ingersoll Rand Security<br />

Technologies<br />

Revision #: 4 Rev Date: May 14 2013<br />

11:28AM EDT<br />

Page 6 of 10


Door # HWSet #<br />

286-1 11<br />

287-1 11<br />

288-1 11<br />

289-1 11<br />

290-1 44<br />

290-2 45<br />

291-1 11<br />

292-1 24<br />

294-1 18<br />

295-1 11<br />

297-1 26<br />

299-1 11<br />

301-1 18<br />

302-1 11<br />

302-2 01<br />

303-1 11<br />

304-1 11<br />

305-1 11<br />

306-1 11<br />

307-1 11<br />

308-1 11<br />

309-1 11<br />

310-1 45<br />

320-1 11<br />

321-1 11<br />

322-1 46<br />

323-1 11<br />

324-1 09<br />

325-1 11<br />

326-1 26<br />

327-1 11<br />

328-1 26<br />

329-1 11<br />

330-1 42<br />

330-2 27<br />

330-3 06<br />

331-1 11<br />

332-1 11<br />

334-1 11<br />

334-2 27<br />

335-1 11<br />

337-1 11<br />

338-1 11<br />

Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />

2013 2:28PM EDT<br />

Supplier: Ingersoll Rand Security<br />

Technologies<br />

Revision #: 4 Rev Date: May 14 2013<br />

11:28AM EDT<br />

Page 7 of 10


Door # HWSet #<br />

339-1 11<br />

340-1 11<br />

341-1 11<br />

343-1 13<br />

350-1 11<br />

351-1 11<br />

352-1 11<br />

353-1 11<br />

354-1 11<br />

354-2 27<br />

355-1 11<br />

356-1 11<br />

366-1 11<br />

367-1 11<br />

368-1 11<br />

368-2 27<br />

369-1 11<br />

370-1 26<br />

370-2 06<br />

371-1 11<br />

373-1 11<br />

374-1 26<br />

375-1 11<br />

376-1 09<br />

377-1 11<br />

378-1 46<br />

379-1 11<br />

380-1 11<br />

381-1 11<br />

382-1 11<br />

385-1 11<br />

386-1 13<br />

387-1 11<br />

389-1 11<br />

390-1 45<br />

392-1 24<br />

394-1 11<br />

395-1 11<br />

395-2 11<br />

395-3 29<br />

397-1 11<br />

399-1 11<br />

399-2 21<br />

Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />

2013 2:28PM EDT<br />

Supplier: Ingersoll Rand Security<br />

Technologies<br />

Revision #: 4 Rev Date: May 14 2013<br />

11:28AM EDT<br />

Page 8 of 10


Door # HWSet #<br />

401-1 18<br />

402-1 11<br />

402-2 15<br />

403-1 11<br />

404-1 11<br />

405-1 11<br />

406-1 24<br />

407-1 11<br />

409-1 13<br />

409-2 18<br />

409-3 11<br />

409-4 47<br />

409-5 11<br />

410-1 45<br />

420-1 11<br />

421-1 11<br />

422-1 11<br />

423-1 11<br />

424-1 10<br />

425-1 11<br />

426-1 26<br />

427-1 11<br />

428-1 26<br />

429-1 11<br />

430-1 42<br />

430-2 27<br />

430-3 06<br />

431-1 11<br />

432-1 11<br />

433-1 11<br />

434-1 11<br />

434-2 27<br />

435-1 11<br />

437-1 11<br />

438-1 11<br />

439-1 11<br />

440-1 11<br />

441-1 11<br />

443-1 13<br />

450-1 11<br />

451-1 11<br />

452-1 11<br />

453-1 11<br />

Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />

2013 2:28PM EDT<br />

Supplier: Ingersoll Rand Security<br />

Technologies<br />

Revision #: 4 Rev Date: May 14 2013<br />

11:28AM EDT<br />

Page 9 of 10


Door # HWSet #<br />

454-1 11<br />

454-2 27<br />

455-1 11<br />

456-1 11<br />

457-1 11<br />

466-1 11<br />

466-2 27<br />

467-1 11<br />

469-1 11<br />

470-1 26<br />

470-2 06<br />

471-1 11<br />

473-1 11<br />

474-1 26<br />

475-1 11<br />

476-1 09<br />

476-2 28<br />

477-1 11<br />

478-1 11<br />

479-1 11<br />

480-1 11<br />

481-1 11<br />

483-1 11<br />

484-1 11<br />

484-2 11<br />

484-3 27<br />

490-1 45<br />

491-1 11<br />

493-1 11<br />

494-1 11<br />

495-1 11<br />

497-1 11<br />

RT-1 29<br />

RT-2 33<br />

RT-2 33<br />

Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />

2013 2:28PM EDT<br />

Supplier: Ingersoll Rand Security<br />

Technologies<br />

Revision #: 4 Rev Date: May 14 2013<br />

11:28AM EDT<br />

Page 10 of 10

Hooray! Your file is uploaded and ready to be published.