Addendum 'B' - Oregon University System
Addendum 'B' - Oregon University System
Addendum 'B' - Oregon University System
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Addendum</strong> ‘B’<br />
Project: <strong>University</strong> of <strong>Oregon</strong> Straub Hall Deferred<br />
Maintenance and Seismic Upgrade<br />
Date: 05/24/2013<br />
To: Bidding Contractors<br />
From: Rowell Brokaw Architects<br />
1.1 GENERAL ITEMS<br />
A. The existing basement slab was core drilled to assess its construction. Based on the core<br />
drill and original construction documents, it should be assumed that the existing<br />
basement slab structure is (2) 3” slabs with a layer of cork waterproofing between.<br />
B. Mechanical, Electrical and Plumbing substitution requests with Engineer review attached.<br />
C. Straub Hall Window Condition Assessment, prepared by the <strong>University</strong> of <strong>Oregon</strong> and<br />
dated May 2011, is attached.<br />
1.2 CHANGES TO DRAWINGS<br />
A. SheetG1.01:<br />
1. Attic Demolition Plan added. Drawing #4.<br />
B. Sheet A2.00:<br />
1. Keynotes at three sump pumps revised.<br />
2. Detail A revised.<br />
3. Door to room V031 changed to cased opening.<br />
C. Sheet A2.01:<br />
1. Gates at stairs S130 and S170 revised to doors.<br />
D. Sheet A2.10:<br />
1. Door 031-2 to room V031 changed to cased opening.<br />
E. Sheet A2.11:<br />
1. Gates 130-4 and 170-2 at stairs S130 and S170 revised to doors.<br />
F. Sheets A2.02, A2.03, A2.04, A2.12, A2.13, A2.14:<br />
1. Keynote A 099 revised to read: “FIX (E) FIRE ESCAPE DOOR IN<br />
PLACE. REMOVE (E) DOOR HARDWARE PER HARDWARE<br />
SCHEDULE.”<br />
G. Sheet A2.20:<br />
1. Lighting quantities revised to match Electric.<br />
H. Sheet A2.21:<br />
1. Lighting quantities revised to match Electric.<br />
2. Chilled beam quantities revised to match Mechanical.<br />
3. Typical Ceiling Layout Key revised.<br />
I. Sheet A2.22:<br />
1. Lighting quantities revised to match Electric.<br />
2. Chilled beam quantities revised to match Mechanical.<br />
3. Removed soffit and revised ceiling in room 299.<br />
4. Typical Ceiling Layout Key revised.<br />
J. Sheet A2.23:<br />
1. Lighting quantities revised to match Electric.<br />
2. Chilled beam quantities revised to match Mechanical.<br />
3. Typical Ceiling Layout Key revised.
K. Sheet A2.24:<br />
1. Lighting layout revised.<br />
2. Typical Ceiling Layout Key revised.<br />
L. Sheet A3.01:<br />
1. Revised to add WINDOW REFURBISHMENT notes.<br />
M. Sheet A3.02:<br />
1. Revised to add WINDOW REFURBISHMENT notes.<br />
2. Keynote A 099 revised to read: “FIX (E) FIRE ESCAPE DOOR IN<br />
PLACE. REMOVE (E) DOOR HARDWARE PER HARDWARE<br />
SCHEDULE.”<br />
3. Revised to add additional detail callouts at elevations 6 and 7.<br />
N. Sheet A4.02:<br />
1. Section #5 revised to reflect change to 1st and 2nd floor WC's from <strong>Addendum</strong> A.<br />
O. Sheet A5.01:<br />
1. Drawings 13 and 14 revised to show door in place of gate on hold open at first<br />
floor stair landings.<br />
P. Sheet A7.05:<br />
1. Detail #3 deleted.<br />
Q. Sheet A7.10:<br />
1. Drawings 4 and 8 revised to remove gate on hold open.<br />
R. Sheet A7.20:<br />
1. Detail 2 revised.<br />
2. Detail 14 added<br />
S. Sheet A8-01:<br />
1. Door Hardware Schedules revised.<br />
2. Door 031-2 revised to cased opening.<br />
3. Doors 130-4 and 170-2 revised from gates to aluminum storefront.<br />
T. Sheet A8-02:<br />
1. Door Hardware Schedules revised.<br />
1.3 CHANGES TO SPECIFICATIONS<br />
A. Section 06 6100 Architectural Fiberglass: Add new specification attached to volume 1 of<br />
specifications<br />
B. Section 08 1116 Aluminum Doors and Frames: Add new specification attached to volume<br />
1 of specifications.<br />
C. Section 08 7100 Door Hardware:<br />
1. Append Door Hardware Schedule and Door Hardware Index attached to end of<br />
section<br />
D. Section 09 2116 Gypsum Board Assemblies:<br />
1. Delete paragraph 2.05-G<br />
2. Delete paragraph 3.09<br />
E. Section 09 5100 Acoustical Ceilings:<br />
1. Add paragraph 2.01-A-3 to read:<br />
“3. Certainteed: www.certainteed.com”<br />
2. Revise paragraph 2.01-C-7 to read:<br />
“7. Product:<br />
a. Ultima Tegular, Fine Texture, Model 1911 by Armstrong<br />
b. Performa 1222BB-IOF-1 by Certainteed”<br />
End of <strong>Addendum</strong> B<br />
Straub DM <strong>Addendum</strong> B 2 / 2
To:<br />
Attn:<br />
Submittal<br />
Rowell Brokaw Architects<br />
1 East Broadway, Suit 300<br />
Eugene, OR Date: May 06, 2013<br />
Project: (UO) STRAUB HALL - DEFERR<br />
ED MAINT<br />
Original Submittal for Prior Approval<br />
1 Copy of Submittals is Attached<br />
TYPE MFG DESCRIPTION<br />
A<br />
Metalumen RM4DI-2-T8-4-OL-OL-W-E-1-277-N<br />
Mfg.<br />
B<br />
Metalumen RM4D-2-T8-4-N-OL-S-E-1-277-N<br />
Mfg.<br />
B1<br />
Metalumen RM4D-2-T8-4-N-OL-Y-E-1-277-N<br />
Mfg.<br />
D Omega OM4LED28277-R4LED40KHZ<br />
D1 Omega OM4LED28277-R4LED40KWWHZ<br />
G<br />
Linear<br />
Lightin<br />
WW6-D-1-ET5-SBL-G-NO-4<br />
Offering T5 Lamping<br />
H<br />
Metalumen RM4D-1L-LED40K-2-OL-(RT OR RD)-X-D350-1-277-N<br />
Mfg.<br />
H1<br />
Metalumen RM4D-1L-LED40K-4-OL-(RT OR RD)-X-D350-1-277-N<br />
Mfg.<br />
H2<br />
Metalumen RM4D-1L-LED40K-4-OL-(RT OR RD)-X-D700-1-277-N<br />
Mfg.<br />
H3<br />
Metalumen RM4D-1L-LED40K-2-OL-(RT OR RD)-X-D700-1-277-N<br />
Mfg.<br />
M<br />
Metalumen RM4D-2-T8-4-N-OL-W-X-E-1-277-N<br />
Mfg.<br />
P<br />
Metalumen RM4DI-2-T8-4-OL-OL-Y-E-1-277-N<br />
Mfg.<br />
SA Omega OM4LED28277-R4LED40KHZ<br />
SA1 Omega OM6LEDXX277DL-R6LED40KHZDL<br />
SB Gardco 941L-20LA-C-DG-NW-UNVI-BRP<br />
V1<br />
Metalumen<br />
Mfg.<br />
RM4D-2-T8-4-OL-S-X-E-1-277-N<br />
Crestron Controls<br />
Remarks:<br />
Page 1
Submittal<br />
To: Rowell Brokaw Architects<br />
1 East Broadway, Suit 300<br />
Eugene, OR Date: May 06, 2013<br />
Project: (UO) STRAUB HALL - DEFERR<br />
Attn:<br />
ED MAINT<br />
TYPE MFG DESCRIPTION<br />
Philips Dynalite Controls<br />
Page 2
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Arch Ltg Works, Up and Under Series<br />
Section 26500 Type: A<br />
PROPOSED SUBSTITUTION: Metalumen, RM4DI-2-T8-4-OL-OL-W-E-1-277-N<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
By Jesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Please provide sample of the<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />
Grande family<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
TYPE A<br />
Ordering Guide<br />
Grande RM4DI<br />
Series<br />
T8, T5, T5H0 DIRECT/IDIRECT – Pendant, Wall<br />
TAB<br />
15<br />
106 [4.2]<br />
135 [5.3]<br />
135 [5.3]<br />
91 [3.6]<br />
91 [3.6]<br />
95 [3.7]<br />
95 [3.7]<br />
Pendant<br />
Wall<br />
Part number example<br />
RM4DI 3 T8 4 N SL Y A E 1 120 N<br />
Model<br />
RM4DI<br />
Number of<br />
Lamps<br />
Lamp<br />
Type<br />
Length<br />
Control<br />
Up<br />
Control<br />
Down<br />
Mounting<br />
Finish<br />
Ballast<br />
Driver<br />
Circuitry Voltage Options<br />
No. of Lamps Length Control Up<br />
2<br />
1 Up/1 Down<br />
2S<br />
1 Up/1 Down<br />
Staggered*<br />
2L<br />
1 Up/1 Down<br />
3<br />
1 Up/2 Down*<br />
3S<br />
1 Up/2 Down<br />
Staggered*<br />
4<br />
2 Up/2 Down*<br />
4S<br />
2 Up/2 Down<br />
Staggered*<br />
*(T8 with opal<br />
satin lens only)<br />
Lamp Type<br />
4<br />
4 Foot<br />
8<br />
8 Foot<br />
12<br />
12 Foot<br />
R<br />
Continuous<br />
Length<br />
(consult<br />
factory)<br />
(fixtures<br />
supplied in<br />
nominal 1’<br />
increments only)<br />
T8 32W<br />
T5 28W<br />
T5HO 54W<br />
LED30K* 3000k<br />
LED35K* 3500k<br />
LED40K* 4000k<br />
*available with opal satin lens only<br />
N<br />
None<br />
OL<br />
Opal<br />
Satin<br />
Lens<br />
Control<br />
Down<br />
SL<br />
Specular<br />
Parabolic<br />
Louver<br />
SSL<br />
Semi<br />
Specular<br />
Parabolic<br />
Louver<br />
OL<br />
Opal Satin<br />
Lens<br />
A<br />
Asymmetrical<br />
reflector<br />
(single T5,<br />
T5HO, T8 only)<br />
Mounting Ballast Circuitry Voltage Options<br />
Pendant<br />
Y<br />
Yoke<br />
Aircraft<br />
Cable<br />
W<br />
Wall<br />
Finish<br />
A Anodized<br />
Aluminum<br />
C Custom<br />
For custom<br />
Finish specify<br />
RAL#<br />
Standard<br />
E<br />
Electronic Instant Start T8<br />
Programmed Rapid Start -T5/T5HO<br />
Dimming 120V/277V Dimming<br />
D1 Advance Mark 7<br />
(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />
D2 Advance Mark 10<br />
(1/2 Lamp T8, 1/2 Lamp T5HO)<br />
D4 Lutron Hi-lume<br />
(1/2 Lamp T8, T5HO)<br />
D5 Lutron Eco-<strong>System</strong><br />
(T5-T5HO-T8) (347V available)<br />
(some lamp/ballast cominations may not be<br />
available — consult factory for availability)<br />
Battery Pack Options<br />
BN1 Bodine B50LP (T8)<br />
BN2 Bodine LP400 (T8)<br />
BN3 Bodine LP500 (T5)<br />
BN4 Bodine LP600 (T5/T5HO/T8)<br />
1<br />
1 Circuit<br />
(Standard)<br />
AB*<br />
Alternating<br />
Switching<br />
EN*<br />
Emergency/<br />
Night Light<br />
LED Driver<br />
/LR*<br />
Left-right<br />
Switching<br />
*n/a for LED<br />
120<br />
277<br />
347*<br />
*(not<br />
available<br />
for LED)<br />
N<br />
None<br />
D<br />
Daylight<br />
Sensor<br />
O<br />
Occupancy<br />
Sensor<br />
DOS<br />
Daylight/<br />
Occupancy<br />
Sensor<br />
Maximum fixture lumens/foot<br />
Standard Dimming 3000k 3500k 4000k<br />
S350 (350mA) D350 (350mA) 959 1019 1065<br />
S700 (700mA) D700 (700mA) 1918 2038 2130<br />
Approvals<br />
R1-07-12<br />
570 Southgate Drive, Guelph, Ontario N1G 4P6<br />
Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />
T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />
www.metalumen.com<br />
(UO) Straub Hall - Deferred Maintenance<br />
Signature<br />
Type A<br />
Metalumen: RM4DI-2-T8-4-OL-OL-W-E-1-277-N<br />
Northern Date Illumination Company<br />
3
TYPE A<br />
Ordering Guide<br />
SPECIFICATIONS<br />
Grande RM4DI<br />
Series<br />
T8, T5, T5H0 DIRECT/IDIRECT – Pendant, Wall<br />
TAB<br />
15<br />
CONSTRUCTION SPECIFICATIONS<br />
T8, T5, T5HO<br />
LED<br />
HOUSING<br />
Rigid extruded aluminum body, 2.0mm [0.08”]<br />
nominal wall thickness. 95mm [3.7”] width x 135mm<br />
[5.3”] high<br />
End Caps: C.R.S.<br />
FINISH<br />
Anodized aluminum, Custom finishes available.<br />
LIGHTING CONTROL OPTIONS<br />
Specular or semi specular parabolic louvre<br />
High transmittance snap in satin lens<br />
Asymmetrical reflector — single lamp only — open<br />
bottom<br />
MOUNTING<br />
PENDANT<br />
Steel aircraft cable yoke complete with a Quick-Grip<br />
field adjustable suspension system provides for quick<br />
and easy onsite alignment.<br />
135 [5.3]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
135 [5.3]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
1<br />
WALL<br />
Wall brackets supplied<br />
106 [4.2]<br />
106 [4.2]<br />
LED/DRIVER SPECIFICATIONS<br />
Medium power LED’s<br />
Color temperatures available: 3000K, 3500K, 4000K<br />
CRI: 84 (4000k) (80 minimum)<br />
Nominal power consumption: 15W - 700mA, 7.5W -<br />
350mA<br />
Hours: 50,000<br />
Maximum delivered lumens/foot:<br />
350mA<br />
3000K 959 lm/ft<br />
3500K 1019 lm/ft<br />
4000K 1065 lm/ft<br />
700mA<br />
3000K 1918 lm/ft<br />
3500K 2038 lm/ft<br />
4000K 2130 lm/ft<br />
Voltage: 120V or 277V input voltage.<br />
Heat Sink: Extruded Aluminum Profile<br />
LED connections: Board mounted connectors.<br />
Drivers: available from several manufacturers.<br />
Drivers matched to run lengths and specific LED light<br />
engines.<br />
135 [5.3]<br />
Wall<br />
91 [3.6]<br />
95 [3.7]<br />
135 [5.3]<br />
Wall<br />
91 [3.6]<br />
95 [3.7]<br />
Certification<br />
Testing Standards: Tested in accordance with IESL-<br />
M79-08<br />
RoHS Compliant<br />
Warranty: 3 year<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type A<br />
Metalumen: RM4DI-2-T8-4-OL-OL-W-E-1-277-N<br />
Northern Illumination Company<br />
4<br />
R1-07-12
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Bartco, IPR8MS Series<br />
Section 26500 Type: B<br />
PROPOSED SUBSTITUTION: Metalumen, RM4D-2-T8-4-N-OL-S-E-1-277-N<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
Date: 5/7/13<br />
By Jesse Smith - Glumac Lighting Studio<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks Must have a wrap lens<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
TYPE B<br />
Ordering Guide<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
106 [4.2]<br />
102 [4.0]<br />
119 [4.7]<br />
119 [4.7]<br />
102 [4.0]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Part number example<br />
91 [3.6]<br />
115 [4.5]<br />
91 [3.6]<br />
120 [4.7]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant Recessed Drywall Recessed T-bar Surface Wall<br />
91 [3.6]<br />
95 [3.7]<br />
Dimensions and photometry see reverse.<br />
RM4D 2S T5 12 N SL RD A E 1 347 N<br />
Model<br />
RM4D<br />
Number of<br />
Lamps<br />
Lamp<br />
Type<br />
Length<br />
Control<br />
Up<br />
N<br />
Control<br />
Down<br />
Mounting<br />
Finish<br />
Ballast<br />
Driver<br />
Circuitry Voltage Options<br />
No. of Lamps Length Control Up<br />
1<br />
1 Lamp<br />
1S<br />
1<br />
Staggered*<br />
1L<br />
1 LED<br />
2<br />
2 Lamps*<br />
2S<br />
2<br />
Staggered*<br />
*(T8 with opal<br />
satin lens<br />
only)<br />
Lamp Type<br />
4<br />
4 Foot<br />
8<br />
8 Foot<br />
12<br />
12 Foot<br />
R<br />
Continuous<br />
Length<br />
(consult<br />
factory)<br />
(fixtures<br />
supplied in<br />
nominal 1’<br />
increments only)<br />
T8 32W<br />
T5 28W<br />
T5HO 54W<br />
LED30K* 3000k<br />
LED35K* 3500k<br />
LED40K* 4000k<br />
*available with opal satin lens only<br />
N<br />
None<br />
Control<br />
Down<br />
SL<br />
Specular<br />
Parabolic<br />
Louver<br />
SSL<br />
Semi<br />
Specular<br />
Parabolic<br />
Louver<br />
OL<br />
Opal Satin<br />
Lens<br />
A<br />
Asymmetrical<br />
reflector<br />
(single T5,<br />
T5HO, T8 only)<br />
Mounting Ballast Circuitry Voltage Options<br />
Pendant<br />
Y<br />
Yoke Aircraft<br />
Cable<br />
RT<br />
Recessed<br />
T-Bar<br />
RD<br />
Recessed<br />
Drywall<br />
S<br />
Surface<br />
W<br />
Wall<br />
Finish<br />
A<br />
Anodized<br />
Aluminum<br />
C<br />
Custom<br />
For custom<br />
Finish specify<br />
RAL#<br />
Standard<br />
E<br />
Electronic Instant Start T8<br />
Programmed Rapid Start -T5/T5HO<br />
Dimming 120V/277V Dimming<br />
D1 Advance Mark 7<br />
(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />
D2 Advance Mark 10<br />
(1/2 Lamp T8, 1/2 Lamp T5HO)<br />
D4 Lutron Hi-lume<br />
(1/2 Lamp T8, T5HO)<br />
D5 Lutron Eco-<strong>System</strong><br />
(T5-T5HO-T8) (347V available)<br />
(some lamp/ballast cominations may<br />
not be available — consult factory for<br />
availability)<br />
Battery Pack Options<br />
BN1 Bodine B50LP (T8)<br />
BN2 Bodine LP400 (T8)<br />
BN3 Bodine LP500 (T5)<br />
BN4 Bodine LP600 (T5/T5HO/T8)<br />
1<br />
1 Circuit<br />
(Standard)<br />
AB*<br />
Alternating<br />
Switching<br />
EN*<br />
Emergency/<br />
Night Light<br />
LED Driver<br />
/LR*<br />
Left-right<br />
Switching<br />
*n/a for LED<br />
120<br />
277<br />
347*<br />
*(not<br />
available<br />
for LED)<br />
N<br />
None<br />
D<br />
Daylight<br />
Sensor<br />
O<br />
Occupancy<br />
Sensor<br />
DOS<br />
Daylight/<br />
Occupancy<br />
Sensor<br />
Maximum fixture lumens/foot<br />
Standard Dimming 3000k 3500k 4000k<br />
S350 (350mA) D350 (350mA) 480 510 533<br />
S700 (700mA) D700 (700mA) 959 1019 1065<br />
Approvals<br />
R1-07-12<br />
570 Southgate Drive, Guelph, Ontario N1G 4P6<br />
Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />
T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />
www.metalumen.com<br />
(UO) Signature Straub Hall - Deferred Maintenance<br />
Type B<br />
Metalumen: RM4D-2-T8-4-N-OL-S-E-1-277-N<br />
Northern Date Illumination Company<br />
1
TYPE B<br />
Ordering Guide<br />
SPECIFICATIONS<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
CONSTRUCTION SPECIFICATIONS<br />
HOUSING<br />
Rigid extruded aluminum body, 2.0mm [0.08”]<br />
nominal wall thickness. 95mm [3.7”] width x 102mm<br />
[4.0”] high (Pendant/Wall/Surface)<br />
115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />
End Caps: C.R.S.<br />
FINISH<br />
Anodized aluminum, Custom finishes available.<br />
T8, T5, T5HO<br />
102 [4.0]<br />
LED<br />
102 [4.0]<br />
LIGHTING CONTROL OPTIONS<br />
Specular or semi specular parabolic louvre<br />
High transmittance snap in satin lens<br />
Asymmetrical reflector — single lamp only — open<br />
bottom<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
MOUNTING<br />
PENDANT<br />
Steel aircraft cable yoke complete with a Quick-Grip<br />
field adjustable suspension system provides for quick<br />
and easy onsite alignment.<br />
119 [4.7]<br />
119 [4.7]<br />
RECESSED<br />
T-Bar — Mounting clips supplied<br />
Drywall — Mounting brackets supplied<br />
WALL<br />
Wall brackets supplied<br />
SURFACE<br />
Direct to surface mount<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
LED/DRIVER SPECIFICATIONS<br />
Medium power LED’s<br />
Color temperatures available: 3000K, 3500K, 4000K<br />
CRI: 84 (4000K) (80 minimum)<br />
Nominal power consumption: 15W - 700mA, 7.5W -<br />
350mA<br />
Hours: 50,000<br />
Maximum delivered lumens/foot:<br />
350mA<br />
3000K 480 lm/ft<br />
3500K 510 lm/ft<br />
4000K 533 lm/ft<br />
700mA<br />
3000K 959 lm/ft<br />
3500K 1019 lm/ft<br />
4000K 1065 lm/ft<br />
Voltage: 120V or 277V input voltage.<br />
Heat Sink: Extruded Aluminum Profile<br />
LED connections: Board mounted connectors.<br />
Drivers: available from several manufacturers.<br />
Drivers matched to run lengths and specific LED light<br />
engines.<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
Certification<br />
Testing Standards: Tested in accordance with IESL-<br />
M79-08<br />
RoHS Compliant<br />
Warranty: 3 year<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type B<br />
Metalumen: RM4D-2-T8-4-N-OL-S-E-1-277-N<br />
Northern Illumination Company<br />
2<br />
Wall<br />
Wall<br />
R1-07-12
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Bartco, IPR8MS Series<br />
Section 26500 Type: B1<br />
PROPOSED SUBSTITUTION: Metalumen, RM4D-2-T8-4-N-OL-Y-E-1-277-N<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
Date: 5/7/13<br />
By Jesse Smith - Glumac Lighting Studio<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks Fixture must have wrap lens<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
TYPE B1<br />
Ordering Guide<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
106 [4.2]<br />
102 [4.0]<br />
119 [4.7]<br />
119 [4.7]<br />
102 [4.0]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Part number example<br />
91 [3.6]<br />
115 [4.5]<br />
91 [3.6]<br />
120 [4.7]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant Recessed Drywall Recessed T-bar Surface Wall<br />
91 [3.6]<br />
95 [3.7]<br />
Dimensions and photometry see reverse.<br />
RM4D 2S T5 12 N SL RD A E 1 347 N<br />
Model<br />
RM4D<br />
Number of<br />
Lamps<br />
Lamp<br />
Type<br />
Length<br />
Control<br />
Up<br />
N<br />
Control<br />
Down<br />
Mounting<br />
Finish<br />
Ballast<br />
Driver<br />
Circuitry Voltage Options<br />
No. of Lamps Length Control Up<br />
1<br />
1 Lamp<br />
1S<br />
1<br />
Staggered*<br />
1L<br />
1 LED<br />
2<br />
2 Lamps*<br />
2S<br />
2<br />
Staggered*<br />
*(T8 with opal<br />
satin lens<br />
only)<br />
Lamp Type<br />
4<br />
4 Foot<br />
8<br />
8 Foot<br />
12<br />
12 Foot<br />
R<br />
Continuous<br />
Length<br />
(consult<br />
factory)<br />
(fixtures<br />
supplied in<br />
nominal 1’<br />
increments only)<br />
T8 32W<br />
T5 28W<br />
T5HO 54W<br />
LED30K* 3000k<br />
LED35K* 3500k<br />
LED40K* 4000k<br />
*available with opal satin lens only<br />
N<br />
None<br />
Control<br />
Down<br />
SL<br />
Specular<br />
Parabolic<br />
Louver<br />
SSL<br />
Semi<br />
Specular<br />
Parabolic<br />
Louver<br />
OL<br />
Opal Satin<br />
Lens<br />
A<br />
Asymmetrical<br />
reflector<br />
(single T5,<br />
T5HO, T8 only)<br />
Mounting Ballast Circuitry Voltage Options<br />
Pendant<br />
Y<br />
Yoke Aircraft<br />
Cable<br />
RT<br />
Recessed<br />
T-Bar<br />
RD<br />
Recessed<br />
Drywall<br />
S<br />
Surface<br />
W<br />
Wall<br />
Finish<br />
A<br />
Anodized<br />
Aluminum<br />
C<br />
Custom<br />
For custom<br />
Finish specify<br />
RAL#<br />
Standard<br />
E<br />
Electronic Instant Start T8<br />
Programmed Rapid Start -T5/T5HO<br />
Dimming 120V/277V Dimming<br />
D1 Advance Mark 7<br />
(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />
D2 Advance Mark 10<br />
(1/2 Lamp T8, 1/2 Lamp T5HO)<br />
D4 Lutron Hi-lume<br />
(1/2 Lamp T8, T5HO)<br />
D5 Lutron Eco-<strong>System</strong><br />
(T5-T5HO-T8) (347V available)<br />
(some lamp/ballast cominations may<br />
not be available — consult factory for<br />
availability)<br />
Battery Pack Options<br />
BN1 Bodine B50LP (T8)<br />
BN2 Bodine LP400 (T8)<br />
BN3 Bodine LP500 (T5)<br />
BN4 Bodine LP600 (T5/T5HO/T8)<br />
1<br />
1 Circuit<br />
(Standard)<br />
AB*<br />
Alternating<br />
Switching<br />
EN*<br />
Emergency/<br />
Night Light<br />
LED Driver<br />
/LR*<br />
Left-right<br />
Switching<br />
*n/a for LED<br />
120<br />
277<br />
347*<br />
*(not<br />
available<br />
for LED)<br />
N<br />
None<br />
D<br />
Daylight<br />
Sensor<br />
O<br />
Occupancy<br />
Sensor<br />
DOS<br />
Daylight/<br />
Occupancy<br />
Sensor<br />
Maximum fixture lumens/foot<br />
Standard Dimming 3000k 3500k 4000k<br />
S350 (350mA) D350 (350mA) 480 510 533<br />
S700 (700mA) D700 (700mA) 959 1019 1065<br />
Approvals<br />
R1-07-12<br />
570 Southgate Drive, Guelph, Ontario N1G 4P6<br />
Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />
T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />
www.metalumen.com<br />
(UO) Signature Straub Hall - Deferred Maintenance<br />
Type B1<br />
Metalumen: RM4D-2-T8-4-N-OL-Y-E-1-277-N<br />
Northern Date Illumination Company<br />
1
TYPE B1<br />
Ordering Guide<br />
SPECIFICATIONS<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
CONSTRUCTION SPECIFICATIONS<br />
HOUSING<br />
Rigid extruded aluminum body, 2.0mm [0.08”]<br />
nominal wall thickness. 95mm [3.7”] width x 102mm<br />
[4.0”] high (Pendant/Wall/Surface)<br />
115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />
End Caps: C.R.S.<br />
FINISH<br />
Anodized aluminum, Custom finishes available.<br />
T8, T5, T5HO<br />
102 [4.0]<br />
LED<br />
102 [4.0]<br />
LIGHTING CONTROL OPTIONS<br />
Specular or semi specular parabolic louvre<br />
High transmittance snap in satin lens<br />
Asymmetrical reflector — single lamp only — open<br />
bottom<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
MOUNTING<br />
PENDANT<br />
Steel aircraft cable yoke complete with a Quick-Grip<br />
field adjustable suspension system provides for quick<br />
and easy onsite alignment.<br />
119 [4.7]<br />
119 [4.7]<br />
RECESSED<br />
T-Bar — Mounting clips supplied<br />
Drywall — Mounting brackets supplied<br />
WALL<br />
Wall brackets supplied<br />
SURFACE<br />
Direct to surface mount<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
LED/DRIVER SPECIFICATIONS<br />
Medium power LED’s<br />
Color temperatures available: 3000K, 3500K, 4000K<br />
CRI: 84 (4000K) (80 minimum)<br />
Nominal power consumption: 15W - 700mA, 7.5W -<br />
350mA<br />
Hours: 50,000<br />
Maximum delivered lumens/foot:<br />
350mA<br />
3000K 480 lm/ft<br />
3500K 510 lm/ft<br />
4000K 533 lm/ft<br />
700mA<br />
3000K 959 lm/ft<br />
3500K 1019 lm/ft<br />
4000K 1065 lm/ft<br />
Voltage: 120V or 277V input voltage.<br />
Heat Sink: Extruded Aluminum Profile<br />
LED connections: Board mounted connectors.<br />
Drivers: available from several manufacturers.<br />
Drivers matched to run lengths and specific LED light<br />
engines.<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
Certification<br />
Testing Standards: Tested in accordance with IESL-<br />
M79-08<br />
RoHS Compliant<br />
Warranty: 3 year<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type B1<br />
Metalumen: RM4D-2-T8-4-N-OL-Y-E-1-277-N<br />
Northern Illumination Company<br />
2<br />
Wall<br />
Wall<br />
R1-07-12
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Portfolio, LD4 Series<br />
Section 26500 Type: D<br />
PROPOSED SUBSTITUTION: Omega, OM4LED28277-R4LED40KHZ<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
ByJesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
application<br />
<br />
Philips Omega Revelation LED downlight utilizes<br />
proprietary remote phosphor technology to produce<br />
one of the most efficient and advanced LED systems<br />
available for general illumination.<br />
light engine<br />
<br />
<br />
<br />
<br />
<br />
<br />
phosphor technology provides increased efficiency<br />
and color stability by redirecting back reflected light.<br />
The phosphor lens assembly converts high brightness<br />
blue light into white light for an even diffused pattern,<br />
eliminating bright spots often created by individual LEDs.<br />
This technology provides consistent, stable color with<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
supply is overload and short circuit protected as well<br />
as thermally regulated to prevent overheating. Sound<br />
<br />
<br />
hours.<br />
<br />
<br />
construction<br />
<br />
<br />
heat sink allows for easy and tool less installation to<br />
the housing yoke. The heat sink is designed to properly<br />
<br />
applications to provide reliable performance over the life<br />
of the light engine. The heat sink incorporates alignment<br />
tabs to properly position with the housing. Rust resistant<br />
springs are used to secure the reflector to the light<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
". Yoke supports weight of heat sink<br />
and light engine assembly to prevent stress on finished<br />
reflector.<br />
<br />
are self flanged and snap to heat sink for consistent<br />
<br />
visual cutoff to source and source image.<br />
<br />
provide vertical and horizontal adjustments. These allow<br />
<br />
" <br />
alignment in 24" O.C. grid systems.<br />
<br />
<br />
inspection below ceiling.<br />
<br />
maintenance of complete system below ceiling.<br />
Removing reflector provides easy access to heat sink and<br />
light engine assembly. This assembly may be removed by<br />
depressing the springs which attach to the yoke and then<br />
simply opening protective cover and unplugging the push<br />
in connector from the LED board.<br />
listings & warranty<br />
TYPE D<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
4" LED 1500 Lumen Downlight<br />
Project<br />
Type<br />
<br />
Comments<br />
<br />
RV11-6.1<br />
<br />
<br />
<br />
<br />
<br />
<br />
–<br />
R4LED<br />
Family<br />
OM4LED<br />
<br />
Wattage<br />
Voltage<br />
120 <br />
<br />
277 <br />
<br />
347 Stepdown<br />
<br />
Option<br />
28 EM – Bodine<br />
<br />
Backup <br />
<br />
– 4" Reflector<br />
CCT<br />
<br />
<br />
<br />
<br />
CS – Clear Specular<br />
CSS <br />
Specular<br />
HZ <br />
GS <br />
WT <br />
PW – Pewter<br />
BZ – Bronze<br />
WH <br />
FF – Finish Flange<br />
<br />
<br />
in emergency mode <br />
<br />
Lumen output varies depending on CCT.<br />
<br />
<br />
<br />
<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type D<br />
Omega: OM4LED28277-R4LED40KHZ<br />
Northern Illumination Company
RV11-6.1<br />
<br />
TYPE D<br />
4" LED 1500 Lumen Downlight<br />
energy data<br />
<br />
<br />
<br />
<br />
dimensions<br />
24-15/16"<br />
(633.7mm)<br />
C<br />
C<br />
6-3/16"<br />
(152.4mm)<br />
10"<br />
(254.7mm)<br />
4-1/2"<br />
(115.1mm)<br />
5-1/8"<br />
(130.1mm)<br />
5-13/16"<br />
(146.9mm)<br />
1-15/16"<br />
(33.7mm)<br />
photometrics<br />
OM4LED28120-R4LED35KCS<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Comp Yearly Energy Cost at<br />
<br />
<br />
45 Cross<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
45 Cross<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
pw <br />
RCR<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
www.omegalighting.com<br />
Canadian Division<br />
<br />
<br />
<br />
Specifications are subject to change without notice.<br />
<br />
lamps that contain small amounts of mercury. Such lamps are labeled,<br />
<br />
mercury must be disposed of in accordance with local requirements.<br />
<br />
(UO) Straub www.lamprecycle.org Hall - Deferred Maintenance<br />
Type D<br />
Omega: OM4LED28277-R4LED40KHZ<br />
Northern Illumination Company
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Portfolio, LD4 Series<br />
Section 26500 Type: D1<br />
PROPOSED SUBSTITUTION: Omega, OM4LED28277-R4LED40KWWHZ<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
ByJesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
application<br />
• Philips Omega Revelation LED downlight utilizes with<br />
the proprietary remote phosphor technology to produce<br />
one of the most efficient and advanced LED systems<br />
available for general illumination.<br />
light engine<br />
• Philips Omega mixing chamber/optical assembly: Remote<br />
phosphor technology provides increased efficiency<br />
and color stability by redirecting back reflected light.<br />
The phosphor lens assembly converts high brightness<br />
blue light into white light for an even diffused pattern,<br />
eliminating bright spots often created by individual LEDs.<br />
This technology provides consistent, stable color with<br />
CCT color control of +/- 100K over the life of the light<br />
engine and provides 20% higher efficiency.<br />
• LED Array: The LED Array consists of a metal core<br />
circuit board with 16 high brightness royal blue LEDs.<br />
• Color: Available in three CCT options, 3000K, 3500K or<br />
4000K with 80CRI +/-2%.<br />
• Electrical: The power supply/driver features Advance<br />
Intelli-volt 120-277VAC 50/60hz, standard dimming<br />
driver with 0-10V analog dimming capability. The power<br />
supply is overload and short circuit protected as well<br />
as thermally regulated to prevent overheating. Sound<br />
rating A. Refer to dimming compatibility spec sheet for<br />
complete details. Driver has rated lifetime of 50,000<br />
hours.<br />
• Lifetime/Lumen Maintenance: 50,000 hour lifetime at<br />
70% lumen maintenance light engine.<br />
construction<br />
• Thermal Management: A proprietary die-cast aluminum<br />
heat sink allows for easy and tool less installation to<br />
the housing yoke. The heat sink is designed to properly<br />
maintain junction temperatures in recessed Non-IC<br />
applications to provide reliable performance over the life<br />
of the light engine. The heat sink incorporates alignment<br />
tabs to properly position with the housing. Rust resistant<br />
springs are used to secure the reflector to the light<br />
engine. Fixtures should not operated or exceed ambient<br />
temperature above 40˚C.<br />
TYPE D1<br />
• Housing: Precision die stamped 18ga galvanized steel<br />
mounting pan and yoke assembly. Allows for ceiling<br />
thickness up to 1-3/8". Yoke supports weight of heat sink<br />
and light engine assembly to prevent stress on finished<br />
reflector.<br />
• Reflector: Precision spun .050 aluminum reflectors<br />
are self flanged and snap to heat sink for consistent<br />
alignment to the optical assembly. Provides 50 degree<br />
visual cutoff to source and source image.<br />
• C-Channels: Revelation C-Channels are included and<br />
provide vertical and horizontal adjustments. These allow<br />
for fast and adjustment free installation in T-bar ceilings<br />
with 1/2" tile. C-Channels simply snap on grid for proper<br />
alignment in 24" O.C. grid systems.<br />
• Junction Box: 16 ga galvanized steel. UL listed for 8 No.<br />
12 AWG, 90C through branch circuit conductors. Allows<br />
inspection below ceiling.<br />
• Service: Modular construction allows for easy<br />
maintenance of complete system below ceiling.<br />
Removing reflector provides easy access to heat sink and<br />
light engine assembly. This assembly may be removed by<br />
depressing the springs which attach to the yoke and then<br />
simply opening protective cover and unplugging the push<br />
in connector from the LED board.<br />
listings & warranty<br />
• ETL, cUL Listed (Suitable for wet location applications.)<br />
• LED life calculations are based upon application junction<br />
temperatures an driver currents at or below IESNA -<br />
LM-80-08 manufacturer’s test data. IES test performed<br />
per IESNA - LM-79-08.<br />
• 5 year Warranty<br />
Architectural Downlighting<br />
OM4LED<br />
4" LED 1500 Lumen Wall Wash<br />
Project<br />
Type<br />
Model No.<br />
Comments<br />
Specifier’s Reference<br />
RV11-6.2<br />
Rev. 4/12<br />
Green Choice: OM4LED28120-R4LED30KWWCS<br />
HOUSING<br />
LIGHT ENGINE - REFLECTOR<br />
OM4LED<br />
28 R4LED WW<br />
–<br />
Family<br />
OM4LED<br />
4 inch housing<br />
Footnotes<br />
Wattage<br />
28 – 28 Input Watts<br />
Voltage<br />
120 - 120 VAC<br />
50/60Hz<br />
277 - 277 VAC<br />
50/60Hz<br />
347 - Stepdown<br />
(347:120/277)<br />
Option<br />
EM – Bodine BSL17C<br />
Emergency Back-up 1<br />
1. Delivered lumen output in emergency mode ranges from 500-550 lumens.<br />
Omega Reflector<br />
R4LED – 4" Reflector<br />
CCT<br />
30K – 3000K<br />
35K – 3500K<br />
40K – 4000K<br />
Reflector Type<br />
WW – Wall Wash<br />
Reflector Finish<br />
CS – Clear Specular<br />
CSS – Clear Semi-<br />
Specular<br />
HZ – Haze<br />
GS – Gold Specular<br />
WT – Wheat<br />
PW – Pewter<br />
BZ – Bronze<br />
WH – White, Paint<br />
FF – Finish Flange<br />
(as suffix to color)<br />
General Notes<br />
Lumen output varies depending on CCT.<br />
Refer to specific IES files for details.<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type D1<br />
Omega: OM4LED28277-R4LED40KWWHZ<br />
Northern Illumination Company
RV11-6.2<br />
Rev.4/12<br />
TYPE D1<br />
4" LED 1500 Lumen Wall Wash<br />
energy data<br />
Input Input Drive Input LED THD Power<br />
Voltage Current Current Power Power % Factor<br />
120 0.234 520mA 28 25 0.9<br />
277 0.101 520mA 28 25 0.9<br />
dimensions<br />
24-15/16"<br />
(633.7mm)<br />
C<br />
C<br />
6-3/16"<br />
(157.2mm)<br />
10"<br />
(254.7mm)<br />
ceiling cutout<br />
4-1/2"<br />
(115.1mm)<br />
5-1/8"<br />
(130.1mm)<br />
1-15/16"<br />
(33.7mm)<br />
5-13/16"<br />
(146.9mm)<br />
photometrics<br />
Consult factory for photometrics.<br />
©2012 Philips Omega<br />
All rights reserved.<br />
776 South Green Street • Tupelo, MS 38804<br />
p. 800.234.1890 • f. 662.841.5501<br />
www.omegalighting.com<br />
Canadian Division<br />
189 Bullock Drive • Markham, Ontario L3P 1W4<br />
p. 905.294.9570 • f. 905.294.9811<br />
Contact Factory for Additional Configurations.<br />
Specifications are subject to change without notice.<br />
Some luminaires use fluorescent or high intensity discharge (HID)<br />
lamps that contain small amounts of mercury. Such lamps are labeled,<br />
“Contain Mercury” and/or the symbol “HG”. Lamps that contain<br />
mercury must be disposed of in accordance with local requirements.<br />
(UO) Straub Information Hall regarding - Deferred lamp recycling Maintenance and disposal can be found at<br />
www.lamprecycle.org<br />
Type D1<br />
Omega: OM4LED28277-R4LED40KWWHZ<br />
Northern Illumination Company
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Arch Ltg Works, Lightplane Series<br />
Section 26500 Type: G<br />
PROPOSED SUBSTITUTION: Linear, WW6-D-1-ET5-SBL-G-NO-4<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
ByJesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks Must be T8 lamping<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
TYPE G<br />
Wall Wash WW6<br />
one or two T5 or T5HO lamps<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type G<br />
Linear: WW6-D-1-ET5-SBL-G-NO-4<br />
Northern Illumination Company
T5 options<br />
Wall Wash WW6<br />
TYPE G<br />
2T5 Wall Wash<br />
3 1 /2” H. x 4 1 /4” W.<br />
2 7 /8” aperture<br />
1T5 Surface Mount Wall Wash<br />
3 1 /8” H. x 3 11 /16” W.<br />
2 5 /16” aperture<br />
1T5 Wall Wash<br />
3 1 /8” H. x 3 11 /16” W.<br />
2 5 /16” aperture<br />
F<br />
Flanged<br />
L<br />
Flangeless<br />
SS<br />
Donn Fineline<br />
G<br />
1” T-bar (4 3 /4” H)<br />
NFG<br />
9<br />
/16” T-bar (4 3 /4”H)<br />
End View Fixture Detail. T’s only are installed perpendicular to lamps. Ceiling tile lays on integral fixture flange.<br />
For design use only. Not for construction. See www.linearltg.com for engineering drawings specific to job.<br />
ae whte steel hosn<br />
or T5T5HO lamps<br />
alale wth sanlaste lens <br />
or parallel lae loer <br />
3<br />
4”H. x 7 8” OC .<br />
ator prewre<br />
C laels<br />
T5 weht per oot 3 ls. approx.<br />
T5 weht per oot 3.5 ls. approx.<br />
90° Plane<br />
WW6-1T5-NS<br />
Efficiency: 62%<br />
Max. candlepower at 30°: 2150<br />
1911 1433 956 478 478 956 1433 1911<br />
90° 270°<br />
60° 300°<br />
30° 350°<br />
0°<br />
See www.linearltg.com for complete photometrics.<br />
Catalog No. Dir. Lamps Ballast Voltage Shielding Mounting Color Add'l options Row length<br />
WW6 - D- 4 - -xxx - - - BW - xxx - xx<br />
Fixture<br />
Lamps & Electrical Options<br />
Direction Direct<br />
Lamps 1 or 2<br />
Ballast ET5 Electronic T5<br />
ET5HO High Output T5<br />
Voltage 120 or 277<br />
347<br />
Offering T5 Lamping<br />
* Dimming ballasts may not be available for all T5/T5HO lamp lengths. Consult factory.<br />
** EM packs may not be available for all T5/T5HO lamp lengths. Consult factory.<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type G<br />
Linear: WW6-D-1-ET5-SBL-G-NO-4<br />
See www.linearltg.com for IES files and additional information.<br />
Northern Illumination Company<br />
Mechanical & Aesthetic Options<br />
Shielding NS No Shielding<br />
SBL Sandblasted Lens<br />
PRL Parallel Blade Louver<br />
Mounting G 1” T-bar<br />
NFG 9<br />
/16” T-bar<br />
SS Donn Fineline<br />
F Flanged<br />
L Flangeless<br />
SMT Surface<br />
Color BW Baked White<br />
Add'l<br />
Feet<br />
NO No Option<br />
Fixture<br />
CB Checkerboard Circuit“A”or“B” lengths<br />
EC Emergency Circuit<br />
Grid<br />
ED Electronic Dimming * 2’, 3’,<br />
EM Emergency Ballast** 4’, 5’<br />
FU Fusing<br />
Flanged and<br />
LO Louver Overlay<br />
Flangeless<br />
LS LutronEcoSys Sensor Feed 2’, 3’, 4’,<br />
NL Night Light<br />
5’, 6’, 8’<br />
PBPS Premium Blst Prog Start<br />
SC Separate Circuits<br />
WP 6ft Long Whip<br />
SF Special Feature<br />
please define<br />
Linear Lighting Corp.<br />
31-30 Hunters Point Ave., Long Island City, NY 11101 ©9/10<br />
718-361-7552 Fax 718-937-2747 Web: www.linearltg.com
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Alight, Accolade Series<br />
Section 26500 Type: H<br />
PROPOSED SUBSTITUTION: Metalumen, RM4D-1L-LED40K-2-OL-(RT OR RD)-X-D350-1-<br />
277-N<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
By<br />
Jesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks We would want to see a sample of<br />
the LED fixture for final approval<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
TYPE H<br />
Ordering Guide<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
106 [4.2]<br />
102 [4.0]<br />
119 [4.7]<br />
119 [4.7]<br />
102 [4.0]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Part number example<br />
91 [3.6]<br />
115 [4.5]<br />
91 [3.6]<br />
120 [4.7]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant Recessed Drywall Recessed T-bar Surface Wall<br />
91 [3.6]<br />
95 [3.7]<br />
Dimensions and photometry see reverse.<br />
RM4D 2S T5 12 N SL RD A E 1 347 N<br />
Model<br />
RM4D<br />
Number of<br />
Lamps<br />
Lamp<br />
Type<br />
Length<br />
Control<br />
Up<br />
N<br />
Control<br />
Down<br />
Mounting<br />
Finish<br />
Ballast<br />
Driver<br />
Circuitry Voltage Options<br />
No. of Lamps Length Control Up<br />
1<br />
1 Lamp<br />
1S<br />
1<br />
Staggered*<br />
1L<br />
1 LED<br />
2<br />
2 Lamps*<br />
2S<br />
2<br />
Staggered*<br />
*(T8 with opal<br />
satin lens<br />
only)<br />
4<br />
4 Foot<br />
8<br />
8 Foot<br />
12<br />
12 Foot<br />
R<br />
Continuous<br />
Length<br />
2 = 2 Foot<br />
(consult<br />
factory)<br />
(fixtures<br />
supplied in<br />
nominal 1’<br />
increments only)<br />
Lamp Type<br />
T8 32W<br />
T5 28W<br />
T5HO 54W<br />
LED30K* 3000k<br />
LED35K* 3500k<br />
LED40K* 4000k<br />
*available with opal satin lens only<br />
N<br />
None<br />
Control<br />
Down<br />
SL<br />
Specular<br />
Parabolic<br />
Louver<br />
SSL<br />
Semi<br />
Specular<br />
Parabolic<br />
Louver<br />
OL<br />
Opal Satin<br />
Lens<br />
A<br />
Asymmetrical<br />
reflector<br />
(single T5,<br />
T5HO, T8 only)<br />
Mounting Ballast Circuitry Voltage Options<br />
Pendant<br />
Y<br />
Yoke Aircraft<br />
Cable<br />
RT<br />
Recessed<br />
T-Bar<br />
RD<br />
Recessed<br />
Drywall<br />
S<br />
Surface<br />
W<br />
Wall<br />
Finish<br />
A<br />
Anodized<br />
Aluminum<br />
C<br />
Custom<br />
For custom<br />
Finish specify<br />
RAL#<br />
Standard<br />
E<br />
Electronic Instant Start T8<br />
Programmed Rapid Start -T5/T5HO<br />
Dimming 120V/277V Dimming<br />
D1 Advance Mark 7<br />
(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />
D2 Advance Mark 10<br />
(1/2 Lamp T8, 1/2 Lamp T5HO)<br />
D4 Lutron Hi-lume<br />
(1/2 Lamp T8, T5HO)<br />
D5 Lutron Eco-<strong>System</strong><br />
(T5-T5HO-T8) (347V available)<br />
(some lamp/ballast cominations may<br />
not be available — consult factory for<br />
availability)<br />
Battery Pack Options<br />
BN1 Bodine B50LP (T8)<br />
BN2 Bodine LP400 (T8)<br />
BN3 Bodine LP500 (T5)<br />
BN4 Bodine LP600 (T5/T5HO/T8)<br />
1<br />
1 Circuit<br />
(Standard)<br />
AB*<br />
Alternating<br />
Switching<br />
EN*<br />
Emergency/<br />
Night Light<br />
LED Driver<br />
/LR*<br />
Left-right<br />
Switching<br />
*n/a for LED<br />
120<br />
277<br />
347*<br />
*(not<br />
available<br />
for LED)<br />
N<br />
None<br />
D<br />
Daylight<br />
Sensor<br />
O<br />
Occupancy<br />
Sensor<br />
DOS<br />
Daylight/<br />
Occupancy<br />
Sensor<br />
Maximum fixture lumens/foot<br />
Standard Dimming 3000k 3500k 4000k<br />
S350 (350mA) D350 (350mA) 480 510 533<br />
S700 (700mA) D700 (700mA) 959 1019 1065<br />
Approvals<br />
R1-07-12<br />
570 Southgate Drive, Guelph, Ontario N1G 4P6<br />
Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />
T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />
www.metalumen.com<br />
1<br />
(UO) Signature Straub Hall - Deferred Maintenance<br />
Type H<br />
Metalumen: RM4D-1L-LED40K-2-OL-(RT OR RD)-X-<br />
D350-1-277-N<br />
Date<br />
Northern Illumination Company
TYPE H<br />
Ordering Guide<br />
SPECIFICATIONS<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
CONSTRUCTION SPECIFICATIONS<br />
HOUSING<br />
Rigid extruded aluminum body, 2.0mm [0.08”]<br />
nominal wall thickness. 95mm [3.7”] width x 102mm<br />
[4.0”] high (Pendant/Wall/Surface)<br />
115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />
End Caps: C.R.S.<br />
FINISH<br />
Anodized aluminum, Custom finishes available.<br />
T8, T5, T5HO<br />
102 [4.0]<br />
LED<br />
102 [4.0]<br />
LIGHTING CONTROL OPTIONS<br />
Specular or semi specular parabolic louvre<br />
High transmittance snap in satin lens<br />
Asymmetrical reflector — single lamp only — open<br />
bottom<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
MOUNTING<br />
PENDANT<br />
Steel aircraft cable yoke complete with a Quick-Grip<br />
field adjustable suspension system provides for quick<br />
and easy onsite alignment.<br />
119 [4.7]<br />
119 [4.7]<br />
RECESSED<br />
T-Bar — Mounting clips supplied<br />
Drywall — Mounting brackets supplied<br />
WALL<br />
Wall brackets supplied<br />
SURFACE<br />
Direct to surface mount<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
LED/DRIVER SPECIFICATIONS<br />
Medium power LED’s<br />
Color temperatures available: 3000K, 3500K, 4000K<br />
CRI: 84 (4000K) (80 minimum)<br />
Nominal power consumption: 15W - 700mA, 7.5W -<br />
350mA<br />
Hours: 50,000<br />
Maximum delivered lumens/foot:<br />
350mA<br />
3000K 480 lm/ft<br />
3500K 510 lm/ft<br />
4000K 533 lm/ft<br />
700mA<br />
3000K 959 lm/ft<br />
3500K 1019 lm/ft<br />
4000K 1065 lm/ft<br />
Voltage: 120V or 277V input voltage.<br />
Heat Sink: Extruded Aluminum Profile<br />
LED connections: Board mounted connectors.<br />
Drivers: available from several manufacturers.<br />
Drivers matched to run lengths and specific LED light<br />
engines.<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
Certification<br />
Testing Standards: Tested in accordance with IESL-<br />
M79-08<br />
RoHS Compliant<br />
Warranty: 3 year<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type H<br />
Metalumen: RM4D-1L-LED40K-2-OL-(RT OR RD)-X-<br />
D350-1-277-N<br />
Northern Illumination Company<br />
102 [4.0]<br />
2<br />
91 [3.6]<br />
95 [3.7]<br />
Wall<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Wall<br />
R1-07-12
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Alight, Accolade Series<br />
Section 26500 Type: H1<br />
PROPOSED SUBSTITUTION: Metalumen, RM4D-1L-LED40K-4-OL-(RT OR RD)-X-D350-1-<br />
277-N<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
By<br />
Jesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks We would want to see a sample of<br />
the LED fixture for final approval<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
TYPE H1<br />
Ordering Guide<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
106 [4.2]<br />
102 [4.0]<br />
119 [4.7]<br />
119 [4.7]<br />
102 [4.0]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Part number example<br />
91 [3.6]<br />
115 [4.5]<br />
91 [3.6]<br />
120 [4.7]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant Recessed Drywall Recessed T-bar Surface Wall<br />
91 [3.6]<br />
95 [3.7]<br />
Dimensions and photometry see reverse.<br />
RM4D 2S T5 12 N SL RD A E 1 347 N<br />
Model<br />
RM4D<br />
Number of<br />
Lamps<br />
Lamp<br />
Type<br />
Length<br />
Control<br />
Up<br />
N<br />
Control<br />
Down<br />
Mounting<br />
Finish<br />
Ballast<br />
Driver<br />
Circuitry Voltage Options<br />
No. of Lamps Length Control Up<br />
1<br />
1 Lamp<br />
1S<br />
1<br />
Staggered*<br />
1L<br />
1 LED<br />
2<br />
2 Lamps*<br />
2S<br />
2<br />
Staggered*<br />
*(T8 with opal<br />
satin lens<br />
only)<br />
Lamp Type<br />
4<br />
4 Foot<br />
8<br />
8 Foot<br />
12<br />
12 Foot<br />
R<br />
Continuous<br />
Length<br />
(consult<br />
factory)<br />
(fixtures<br />
supplied in<br />
nominal 1’<br />
increments only)<br />
T8 32W<br />
T5 28W<br />
T5HO 54W<br />
LED30K* 3000k<br />
LED35K* 3500k<br />
LED40K* 4000k<br />
*available with opal satin lens only<br />
N<br />
None<br />
Control<br />
Down<br />
SL<br />
Specular<br />
Parabolic<br />
Louver<br />
SSL<br />
Semi<br />
Specular<br />
Parabolic<br />
Louver<br />
OL<br />
Opal Satin<br />
Lens<br />
A<br />
Asymmetrical<br />
reflector<br />
(single T5,<br />
T5HO, T8 only)<br />
Mounting Ballast Circuitry Voltage Options<br />
Pendant<br />
Y<br />
Yoke Aircraft<br />
Cable<br />
RT<br />
Recessed<br />
T-Bar<br />
RD<br />
Recessed<br />
Drywall<br />
S<br />
Surface<br />
W<br />
Wall<br />
Finish<br />
A<br />
Anodized<br />
Aluminum<br />
C<br />
Custom<br />
For custom<br />
Finish specify<br />
RAL#<br />
Standard<br />
E<br />
Electronic Instant Start T8<br />
Programmed Rapid Start -T5/T5HO<br />
Dimming 120V/277V Dimming<br />
D1 Advance Mark 7<br />
(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />
D2 Advance Mark 10<br />
(1/2 Lamp T8, 1/2 Lamp T5HO)<br />
D4 Lutron Hi-lume<br />
(1/2 Lamp T8, T5HO)<br />
D5 Lutron Eco-<strong>System</strong><br />
(T5-T5HO-T8) (347V available)<br />
(some lamp/ballast cominations may<br />
not be available — consult factory for<br />
availability)<br />
Battery Pack Options<br />
BN1 Bodine B50LP (T8)<br />
BN2 Bodine LP400 (T8)<br />
BN3 Bodine LP500 (T5)<br />
BN4 Bodine LP600 (T5/T5HO/T8)<br />
1<br />
1 Circuit<br />
(Standard)<br />
AB*<br />
Alternating<br />
Switching<br />
EN*<br />
Emergency/<br />
Night Light<br />
LED Driver<br />
/LR*<br />
Left-right<br />
Switching<br />
*n/a for LED<br />
120<br />
277<br />
347*<br />
*(not<br />
available<br />
for LED)<br />
N<br />
None<br />
D<br />
Daylight<br />
Sensor<br />
O<br />
Occupancy<br />
Sensor<br />
DOS<br />
Daylight/<br />
Occupancy<br />
Sensor<br />
Maximum fixture lumens/foot<br />
Standard Dimming 3000k 3500k 4000k<br />
S350 (350mA) D350 (350mA) 480 510 533<br />
S700 (700mA) D700 (700mA) 959 1019 1065<br />
Approvals<br />
R1-07-12<br />
570 Southgate Drive, Guelph, Ontario N1G 4P6<br />
Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />
T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />
www.metalumen.com<br />
1<br />
(UO) Straub Hall - Deferred Maintenance<br />
Signature<br />
Type H1<br />
Metalumen: RM4D-1L-LED40K-4-OL-(RT OR RD)-X-<br />
D350-1-277-N<br />
Date<br />
Northern Illumination Company
TYPE H1<br />
Ordering Guide<br />
SPECIFICATIONS<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
CONSTRUCTION SPECIFICATIONS<br />
HOUSING<br />
Rigid extruded aluminum body, 2.0mm [0.08”]<br />
nominal wall thickness. 95mm [3.7”] width x 102mm<br />
[4.0”] high (Pendant/Wall/Surface)<br />
115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />
End Caps: C.R.S.<br />
FINISH<br />
Anodized aluminum, Custom finishes available.<br />
T8, T5, T5HO<br />
102 [4.0]<br />
LED<br />
102 [4.0]<br />
LIGHTING CONTROL OPTIONS<br />
Specular or semi specular parabolic louvre<br />
High transmittance snap in satin lens<br />
Asymmetrical reflector — single lamp only — open<br />
bottom<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
MOUNTING<br />
PENDANT<br />
Steel aircraft cable yoke complete with a Quick-Grip<br />
field adjustable suspension system provides for quick<br />
and easy onsite alignment.<br />
119 [4.7]<br />
119 [4.7]<br />
RECESSED<br />
T-Bar — Mounting clips supplied<br />
Drywall — Mounting brackets supplied<br />
WALL<br />
Wall brackets supplied<br />
SURFACE<br />
Direct to surface mount<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
LED/DRIVER SPECIFICATIONS<br />
Medium power LED’s<br />
Color temperatures available: 3000K, 3500K, 4000K<br />
CRI: 84 (4000K) (80 minimum)<br />
Nominal power consumption: 15W - 700mA, 7.5W -<br />
350mA<br />
Hours: 50,000<br />
Maximum delivered lumens/foot:<br />
350mA<br />
3000K 480 lm/ft<br />
3500K 510 lm/ft<br />
4000K 533 lm/ft<br />
700mA<br />
3000K 959 lm/ft<br />
3500K 1019 lm/ft<br />
4000K 1065 lm/ft<br />
Voltage: 120V or 277V input voltage.<br />
Heat Sink: Extruded Aluminum Profile<br />
LED connections: Board mounted connectors.<br />
Drivers: available from several manufacturers.<br />
Drivers matched to run lengths and specific LED light<br />
engines.<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
Certification<br />
Testing Standards: Tested in accordance with IESL-<br />
M79-08<br />
RoHS Compliant<br />
Warranty: 3 year<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type H1<br />
Metalumen: RM4D-1L-LED40K-4-OL-(RT OR RD)-X-<br />
D350-1-277-N<br />
Northern Illumination Company<br />
102 [4.0]<br />
2<br />
91 [3.6]<br />
95 [3.7]<br />
Wall<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Wall<br />
R1-07-12
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Alight, Accolade Series<br />
Section 26500 Type: H2<br />
PROPOSED SUBSTITUTION: Metalumen, RM4D-1L-LED40K-4-OL-(RT OR RD)-X-D700-1-<br />
277-N<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
By<br />
Jesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks We would want to see a sample of<br />
the LED fixture for final approval<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
TYPE H2<br />
Ordering Guide<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
106 [4.2]<br />
102 [4.0]<br />
119 [4.7]<br />
119 [4.7]<br />
102 [4.0]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Part number example<br />
91 [3.6]<br />
115 [4.5]<br />
91 [3.6]<br />
120 [4.7]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant Recessed Drywall Recessed T-bar Surface Wall<br />
91 [3.6]<br />
95 [3.7]<br />
Dimensions and photometry see reverse.<br />
RM4D 2S T5 12 N SL RD A E 1 347 N<br />
Model<br />
RM4D<br />
Number of<br />
Lamps<br />
Lamp<br />
Type<br />
Length<br />
Control<br />
Up<br />
N<br />
Control<br />
Down<br />
Mounting<br />
Finish<br />
Ballast<br />
Driver<br />
Circuitry Voltage Options<br />
No. of Lamps Length Control Up<br />
1<br />
1 Lamp<br />
1S<br />
1<br />
Staggered*<br />
1L<br />
1 LED<br />
2<br />
2 Lamps*<br />
2S<br />
2<br />
Staggered*<br />
*(T8 with opal<br />
satin lens<br />
only)<br />
Lamp Type<br />
4<br />
4 Foot<br />
8<br />
8 Foot<br />
12<br />
12 Foot<br />
R<br />
Continuous<br />
Length<br />
(consult<br />
factory)<br />
(fixtures<br />
supplied in<br />
nominal 1’<br />
increments only)<br />
T8 32W<br />
T5 28W<br />
T5HO 54W<br />
LED30K* 3000k<br />
LED35K* 3500k<br />
LED40K* 4000k<br />
*available with opal satin lens only<br />
N<br />
None<br />
Control<br />
Down<br />
SL<br />
Specular<br />
Parabolic<br />
Louver<br />
SSL<br />
Semi<br />
Specular<br />
Parabolic<br />
Louver<br />
OL<br />
Opal Satin<br />
Lens<br />
A<br />
Asymmetrical<br />
reflector<br />
(single T5,<br />
T5HO, T8 only)<br />
Mounting Ballast Circuitry Voltage Options<br />
Pendant<br />
Y<br />
Yoke Aircraft<br />
Cable<br />
RT<br />
Recessed<br />
T-Bar<br />
RD<br />
Recessed<br />
Drywall<br />
S<br />
Surface<br />
W<br />
Wall<br />
Finish<br />
A<br />
Anodized<br />
Aluminum<br />
C<br />
Custom<br />
For custom<br />
Finish specify<br />
RAL#<br />
Standard<br />
E<br />
Electronic Instant Start T8<br />
Programmed Rapid Start -T5/T5HO<br />
Dimming 120V/277V Dimming<br />
D1 Advance Mark 7<br />
(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />
D2 Advance Mark 10<br />
(1/2 Lamp T8, 1/2 Lamp T5HO)<br />
D4 Lutron Hi-lume<br />
(1/2 Lamp T8, T5HO)<br />
D5 Lutron Eco-<strong>System</strong><br />
(T5-T5HO-T8) (347V available)<br />
(some lamp/ballast cominations may<br />
not be available — consult factory for<br />
availability)<br />
Battery Pack Options<br />
BN1 Bodine B50LP (T8)<br />
BN2 Bodine LP400 (T8)<br />
BN3 Bodine LP500 (T5)<br />
BN4 Bodine LP600 (T5/T5HO/T8)<br />
1<br />
1 Circuit<br />
(Standard)<br />
AB*<br />
Alternating<br />
Switching<br />
EN*<br />
Emergency/<br />
Night Light<br />
LED Driver<br />
/LR*<br />
Left-right<br />
Switching<br />
*n/a for LED<br />
120<br />
277<br />
347*<br />
*(not<br />
available<br />
for LED)<br />
N<br />
None<br />
D<br />
Daylight<br />
Sensor<br />
O<br />
Occupancy<br />
Sensor<br />
DOS<br />
Daylight/<br />
Occupancy<br />
Sensor<br />
Maximum fixture lumens/foot<br />
Standard Dimming 3000k 3500k 4000k<br />
S350 (350mA) D350 (350mA) 480 510 533<br />
S700 (700mA) D700 (700mA) 959 1019 1065<br />
Approvals<br />
R1-07-12<br />
570 Southgate Drive, Guelph, Ontario N1G 4P6<br />
Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />
T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />
www.metalumen.com<br />
1<br />
(UO) Signature Straub Hall - Deferred Maintenance<br />
Type H2<br />
Metalumen: RM4D-1L-LED40K-4-OL-(RT OR RD)-X-<br />
D700-1-277-N<br />
Date<br />
Northern Illumination Company
TYPE H2<br />
Ordering Guide<br />
SPECIFICATIONS<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
CONSTRUCTION SPECIFICATIONS<br />
HOUSING<br />
Rigid extruded aluminum body, 2.0mm [0.08”]<br />
nominal wall thickness. 95mm [3.7”] width x 102mm<br />
[4.0”] high (Pendant/Wall/Surface)<br />
115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />
End Caps: C.R.S.<br />
FINISH<br />
Anodized aluminum, Custom finishes available.<br />
T8, T5, T5HO<br />
102 [4.0]<br />
LED<br />
102 [4.0]<br />
LIGHTING CONTROL OPTIONS<br />
Specular or semi specular parabolic louvre<br />
High transmittance snap in satin lens<br />
Asymmetrical reflector — single lamp only — open<br />
bottom<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
MOUNTING<br />
PENDANT<br />
Steel aircraft cable yoke complete with a Quick-Grip<br />
field adjustable suspension system provides for quick<br />
and easy onsite alignment.<br />
119 [4.7]<br />
119 [4.7]<br />
RECESSED<br />
T-Bar — Mounting clips supplied<br />
Drywall — Mounting brackets supplied<br />
WALL<br />
Wall brackets supplied<br />
SURFACE<br />
Direct to surface mount<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
LED/DRIVER SPECIFICATIONS<br />
Medium power LED’s<br />
Color temperatures available: 3000K, 3500K, 4000K<br />
CRI: 84 (4000K) (80 minimum)<br />
Nominal power consumption: 15W - 700mA, 7.5W -<br />
350mA<br />
Hours: 50,000<br />
Maximum delivered lumens/foot:<br />
350mA<br />
3000K 480 lm/ft<br />
3500K 510 lm/ft<br />
4000K 533 lm/ft<br />
700mA<br />
3000K 959 lm/ft<br />
3500K 1019 lm/ft<br />
4000K 1065 lm/ft<br />
Voltage: 120V or 277V input voltage.<br />
Heat Sink: Extruded Aluminum Profile<br />
LED connections: Board mounted connectors.<br />
Drivers: available from several manufacturers.<br />
Drivers matched to run lengths and specific LED light<br />
engines.<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
Certification<br />
Testing Standards: Tested in accordance with IESL-<br />
M79-08<br />
RoHS Compliant<br />
Warranty: 3 year<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type H2<br />
Metalumen: RM4D-1L-LED40K-4-OL-(RT OR RD)-X-<br />
D700-1-277-N<br />
Northern Illumination Company<br />
102 [4.0]<br />
2<br />
91 [3.6]<br />
95 [3.7]<br />
Wall<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Wall<br />
R1-07-12
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Alight, Accolade Series<br />
Section 26500 Type: H3<br />
PROPOSED SUBSTITUTION: Metalumen, RM4D-1L-LED40K-2-OL-(RT OR RD)-X-D700-1-<br />
277-N<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
By<br />
Jesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks We would want to see a sample of<br />
the LED fixture for final approval<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
TYPE H3<br />
Ordering Guide<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
106 [4.2]<br />
102 [4.0]<br />
119 [4.7]<br />
119 [4.7]<br />
102 [4.0]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Part number example<br />
91 [3.6]<br />
115 [4.5]<br />
91 [3.6]<br />
120 [4.7]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant Recessed Drywall Recessed T-bar Surface Wall<br />
91 [3.6]<br />
95 [3.7]<br />
Dimensions and photometry see reverse.<br />
RM4D 2S T5 12 N SL RD A E 1 347 N<br />
Model<br />
RM4D<br />
Number of<br />
Lamps<br />
Lamp<br />
Type<br />
Length<br />
Control<br />
Up<br />
N<br />
Control<br />
Down<br />
Mounting<br />
Finish<br />
Ballast<br />
Driver<br />
Circuitry Voltage Options<br />
No. of Lamps Length Control Up<br />
1<br />
1 Lamp<br />
1S<br />
1<br />
Staggered*<br />
1L<br />
1 LED<br />
2<br />
2 Lamps*<br />
2S<br />
2<br />
Staggered*<br />
*(T8 with opal<br />
satin lens<br />
only)<br />
4<br />
4 Foot<br />
8<br />
8 Foot<br />
12<br />
12 Foot<br />
R<br />
Continuous<br />
Length<br />
2 = 2 Foot<br />
(consult<br />
factory)<br />
(fixtures<br />
supplied in<br />
nominal 1’<br />
increments only)<br />
Lamp Type<br />
T8 32W<br />
T5 28W<br />
T5HO 54W<br />
LED30K* 3000k<br />
LED35K* 3500k<br />
LED40K* 4000k<br />
*available with opal satin lens only<br />
N<br />
None<br />
Control<br />
Down<br />
SL<br />
Specular<br />
Parabolic<br />
Louver<br />
SSL<br />
Semi<br />
Specular<br />
Parabolic<br />
Louver<br />
OL<br />
Opal Satin<br />
Lens<br />
A<br />
Asymmetrical<br />
reflector<br />
(single T5,<br />
T5HO, T8 only)<br />
Mounting Ballast Circuitry Voltage Options<br />
Pendant<br />
Y<br />
Yoke Aircraft<br />
Cable<br />
RT<br />
Recessed<br />
T-Bar<br />
RD<br />
Recessed<br />
Drywall<br />
S<br />
Surface<br />
W<br />
Wall<br />
Finish<br />
A<br />
Anodized<br />
Aluminum<br />
C<br />
Custom<br />
For custom<br />
Finish specify<br />
RAL#<br />
Standard<br />
E<br />
Electronic Instant Start T8<br />
Programmed Rapid Start -T5/T5HO<br />
Dimming 120V/277V Dimming<br />
D1 Advance Mark 7<br />
(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />
D2 Advance Mark 10<br />
(1/2 Lamp T8, 1/2 Lamp T5HO)<br />
D4 Lutron Hi-lume<br />
(1/2 Lamp T8, T5HO)<br />
D5 Lutron Eco-<strong>System</strong><br />
(T5-T5HO-T8) (347V available)<br />
(some lamp/ballast cominations may<br />
not be available — consult factory for<br />
availability)<br />
Battery Pack Options<br />
BN1 Bodine B50LP (T8)<br />
BN2 Bodine LP400 (T8)<br />
BN3 Bodine LP500 (T5)<br />
BN4 Bodine LP600 (T5/T5HO/T8)<br />
1<br />
1 Circuit<br />
(Standard)<br />
AB*<br />
Alternating<br />
Switching<br />
EN*<br />
Emergency/<br />
Night Light<br />
LED Driver<br />
/LR*<br />
Left-right<br />
Switching<br />
*n/a for LED<br />
120<br />
277<br />
347*<br />
*(not<br />
available<br />
for LED)<br />
N<br />
None<br />
D<br />
Daylight<br />
Sensor<br />
O<br />
Occupancy<br />
Sensor<br />
DOS<br />
Daylight/<br />
Occupancy<br />
Sensor<br />
Maximum fixture lumens/foot<br />
Standard Dimming 3000k 3500k 4000k<br />
S350 (350mA) D350 (350mA) 480 510 533<br />
S700 (700mA) D700 (700mA) 959 1019 1065<br />
Approvals<br />
R1-07-12<br />
570 Southgate Drive, Guelph, Ontario N1G 4P6<br />
Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />
T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />
www.metalumen.com<br />
1<br />
(UO) Signature Straub Hall - Deferred Maintenance<br />
Type H3<br />
Metalumen: RM4D-1L-LED40K-2-OL-(RT OR RD)-X-<br />
D700-1-277-N<br />
Date<br />
Northern Illumination Company
TYPE H3<br />
Ordering Guide<br />
SPECIFICATIONS<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
CONSTRUCTION SPECIFICATIONS<br />
HOUSING<br />
Rigid extruded aluminum body, 2.0mm [0.08”]<br />
nominal wall thickness. 95mm [3.7”] width x 102mm<br />
[4.0”] high (Pendant/Wall/Surface)<br />
115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />
End Caps: C.R.S.<br />
FINISH<br />
Anodized aluminum, Custom finishes available.<br />
T8, T5, T5HO<br />
102 [4.0]<br />
LED<br />
102 [4.0]<br />
LIGHTING CONTROL OPTIONS<br />
Specular or semi specular parabolic louvre<br />
High transmittance snap in satin lens<br />
Asymmetrical reflector — single lamp only — open<br />
bottom<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
MOUNTING<br />
PENDANT<br />
Steel aircraft cable yoke complete with a Quick-Grip<br />
field adjustable suspension system provides for quick<br />
and easy onsite alignment.<br />
119 [4.7]<br />
119 [4.7]<br />
RECESSED<br />
T-Bar — Mounting clips supplied<br />
Drywall — Mounting brackets supplied<br />
WALL<br />
Wall brackets supplied<br />
SURFACE<br />
Direct to surface mount<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
LED/DRIVER SPECIFICATIONS<br />
Medium power LED’s<br />
Color temperatures available: 3000K, 3500K, 4000K<br />
CRI: 84 (4000K) (80 minimum)<br />
Nominal power consumption: 15W - 700mA, 7.5W -<br />
350mA<br />
Hours: 50,000<br />
Maximum delivered lumens/foot:<br />
350mA<br />
3000K 480 lm/ft<br />
3500K 510 lm/ft<br />
4000K 533 lm/ft<br />
700mA<br />
3000K 959 lm/ft<br />
3500K 1019 lm/ft<br />
4000K 1065 lm/ft<br />
Voltage: 120V or 277V input voltage.<br />
Heat Sink: Extruded Aluminum Profile<br />
LED connections: Board mounted connectors.<br />
Drivers: available from several manufacturers.<br />
Drivers matched to run lengths and specific LED light<br />
engines.<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
Certification<br />
Testing Standards: Tested in accordance with IESL-<br />
M79-08<br />
RoHS Compliant<br />
Warranty: 3 year<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type H3<br />
Metalumen: RM4D-1L-LED40K-2-OL-(RT OR RD)-X-<br />
D700-1-277-N<br />
Northern Illumination Company<br />
102 [4.0]<br />
2<br />
91 [3.6]<br />
95 [3.7]<br />
Wall<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Wall<br />
R1-07-12
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Bartco, IPR8MS Series<br />
Section 26500 Type: M<br />
PROPOSED SUBSTITUTION: Metalumen, RM4D-2-T8-4-N-OL-W-X-E-1-277-N<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
Date: 5/7/13<br />
By Jesse Smith - Glumac Lighting Studio<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks Fixture must have wrap lens<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
TYPE M<br />
Ordering Guide<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
106 [4.2]<br />
102 [4.0]<br />
119 [4.7]<br />
119 [4.7]<br />
102 [4.0]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Part number example<br />
91 [3.6]<br />
115 [4.5]<br />
91 [3.6]<br />
120 [4.7]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant Recessed Drywall Recessed T-bar Surface Wall<br />
91 [3.6]<br />
95 [3.7]<br />
Dimensions and photometry see reverse.<br />
RM4D 2S T5 12 N SL RD A E 1 347 N<br />
Model<br />
RM4D<br />
Number of<br />
Lamps<br />
Lamp<br />
Type<br />
Length<br />
Control<br />
Up<br />
N<br />
Control<br />
Down<br />
Mounting<br />
Finish<br />
Ballast<br />
Driver<br />
Circuitry Voltage Options<br />
No. of Lamps Length Control Up<br />
1<br />
1 Lamp<br />
1S<br />
1<br />
Staggered*<br />
1L<br />
1 LED<br />
2<br />
2 Lamps*<br />
2S<br />
2<br />
Staggered*<br />
*(T8 with opal<br />
satin lens<br />
only)<br />
Lamp Type<br />
4<br />
4 Foot<br />
8<br />
8 Foot<br />
12<br />
12 Foot<br />
R<br />
Continuous<br />
Length<br />
(consult<br />
factory)<br />
(fixtures<br />
supplied in<br />
nominal 1’<br />
increments only)<br />
T8 32W<br />
T5 28W<br />
T5HO 54W<br />
LED30K* 3000k<br />
LED35K* 3500k<br />
LED40K* 4000k<br />
*available with opal satin lens only<br />
N<br />
None<br />
Control<br />
Down<br />
SL<br />
Specular<br />
Parabolic<br />
Louver<br />
SSL<br />
Semi<br />
Specular<br />
Parabolic<br />
Louver<br />
OL<br />
Opal Satin<br />
Lens<br />
A<br />
Asymmetrical<br />
reflector<br />
(single T5,<br />
T5HO, T8 only)<br />
Mounting Ballast Circuitry Voltage Options<br />
Pendant<br />
Y<br />
Yoke Aircraft<br />
Cable<br />
RT<br />
Recessed<br />
T-Bar<br />
RD<br />
Recessed<br />
Drywall<br />
S<br />
Surface<br />
W<br />
Wall<br />
Finish<br />
A<br />
Anodized<br />
Aluminum<br />
C<br />
Custom<br />
For custom<br />
Finish specify<br />
RAL#<br />
Standard<br />
E<br />
Electronic Instant Start T8<br />
Programmed Rapid Start -T5/T5HO<br />
Dimming 120V/277V Dimming<br />
D1 Advance Mark 7<br />
(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />
D2 Advance Mark 10<br />
(1/2 Lamp T8, 1/2 Lamp T5HO)<br />
D4 Lutron Hi-lume<br />
(1/2 Lamp T8, T5HO)<br />
D5 Lutron Eco-<strong>System</strong><br />
(T5-T5HO-T8) (347V available)<br />
(some lamp/ballast cominations may<br />
not be available — consult factory for<br />
availability)<br />
Battery Pack Options<br />
BN1 Bodine B50LP (T8)<br />
BN2 Bodine LP400 (T8)<br />
BN3 Bodine LP500 (T5)<br />
BN4 Bodine LP600 (T5/T5HO/T8)<br />
1<br />
1 Circuit<br />
(Standard)<br />
AB*<br />
Alternating<br />
Switching<br />
EN*<br />
Emergency/<br />
Night Light<br />
LED Driver<br />
/LR*<br />
Left-right<br />
Switching<br />
*n/a for LED<br />
120<br />
277<br />
347*<br />
*(not<br />
available<br />
for LED)<br />
N<br />
None<br />
D<br />
Daylight<br />
Sensor<br />
O<br />
Occupancy<br />
Sensor<br />
DOS<br />
Daylight/<br />
Occupancy<br />
Sensor<br />
Maximum fixture lumens/foot<br />
Standard Dimming 3000k 3500k 4000k<br />
S350 (350mA) D350 (350mA) 480 510 533<br />
S700 (700mA) D700 (700mA) 959 1019 1065<br />
Approvals<br />
R1-07-12<br />
570 Southgate Drive, Guelph, Ontario N1G 4P6<br />
Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />
T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />
www.metalumen.com<br />
(UO) Straub Hall - Deferred Maintenance<br />
Signature<br />
Type M<br />
Metalumen: RM4D-2-T8-4-N-OL-W-X-E-1-277-N<br />
Northern Date Illumination Company<br />
1
TYPE M<br />
Ordering Guide<br />
SPECIFICATIONS<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
CONSTRUCTION SPECIFICATIONS<br />
HOUSING<br />
Rigid extruded aluminum body, 2.0mm [0.08”]<br />
nominal wall thickness. 95mm [3.7”] width x 102mm<br />
[4.0”] high (Pendant/Wall/Surface)<br />
115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />
End Caps: C.R.S.<br />
FINISH<br />
Anodized aluminum, Custom finishes available.<br />
T8, T5, T5HO<br />
102 [4.0]<br />
LED<br />
102 [4.0]<br />
LIGHTING CONTROL OPTIONS<br />
Specular or semi specular parabolic louvre<br />
High transmittance snap in satin lens<br />
Asymmetrical reflector — single lamp only — open<br />
bottom<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
MOUNTING<br />
PENDANT<br />
Steel aircraft cable yoke complete with a Quick-Grip<br />
field adjustable suspension system provides for quick<br />
and easy onsite alignment.<br />
119 [4.7]<br />
119 [4.7]<br />
RECESSED<br />
T-Bar — Mounting clips supplied<br />
Drywall — Mounting brackets supplied<br />
WALL<br />
Wall brackets supplied<br />
SURFACE<br />
Direct to surface mount<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
LED/DRIVER SPECIFICATIONS<br />
Medium power LED’s<br />
Color temperatures available: 3000K, 3500K, 4000K<br />
CRI: 84 (4000K) (80 minimum)<br />
Nominal power consumption: 15W - 700mA, 7.5W -<br />
350mA<br />
Hours: 50,000<br />
Maximum delivered lumens/foot:<br />
350mA<br />
3000K 480 lm/ft<br />
3500K 510 lm/ft<br />
4000K 533 lm/ft<br />
700mA<br />
3000K 959 lm/ft<br />
3500K 1019 lm/ft<br />
4000K 1065 lm/ft<br />
Voltage: 120V or 277V input voltage.<br />
Heat Sink: Extruded Aluminum Profile<br />
LED connections: Board mounted connectors.<br />
Drivers: available from several manufacturers.<br />
Drivers matched to run lengths and specific LED light<br />
engines.<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
Certification<br />
Testing Standards: Tested in accordance with IESL-<br />
M79-08<br />
RoHS Compliant<br />
Warranty: 3 year<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type M<br />
Metalumen: RM4D-2-T8-4-N-OL-W-X-E-1-277-N<br />
Northern Illumination Company<br />
2<br />
Wall<br />
Wall<br />
R1-07-12
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Arch Ltg Works, Up and Under Series<br />
Section 26500 Type: P<br />
PROPOSED SUBSTITUTION: Metalumen, RM4DI-2-T8-4-OL-OL-Y-E-1-277-N<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
By Jesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Please provide sample of the<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />
Grande family. Photometrics will<br />
also have to be calculated to show<br />
The Construction Specifications Institute performance is met September within the 1997<br />
Northwest Region<br />
classroom spaces.
TYPE P<br />
Ordering Guide<br />
Grande RM4DI<br />
Series<br />
T8, T5, T5H0 DIRECT/IDIRECT – Pendant, Wall<br />
TAB<br />
15<br />
106 [4.2]<br />
135 [5.3]<br />
135 [5.3]<br />
91 [3.6]<br />
91 [3.6]<br />
95 [3.7]<br />
95 [3.7]<br />
Pendant<br />
Wall<br />
Part number example<br />
RM4DI 3 T8 4 N SL Y A E 1 120 N<br />
Model<br />
RM4DI<br />
Number of<br />
Lamps<br />
Lamp<br />
Type<br />
Length<br />
Control<br />
Up<br />
Control<br />
Down<br />
Mounting<br />
Finish<br />
Ballast<br />
Driver<br />
Circuitry Voltage Options<br />
No. of Lamps Length Control Up<br />
2<br />
1 Up/1 Down<br />
2S<br />
1 Up/1 Down<br />
Staggered*<br />
2L<br />
1 Up/1 Down<br />
3<br />
1 Up/2 Down*<br />
3S<br />
1 Up/2 Down<br />
Staggered*<br />
4<br />
2 Up/2 Down*<br />
4S<br />
2 Up/2 Down<br />
Staggered*<br />
*(T8 with opal<br />
satin lens only)<br />
Lamp Type<br />
4<br />
4 Foot<br />
8<br />
8 Foot<br />
12<br />
12 Foot<br />
R<br />
Continuous<br />
Length<br />
(consult<br />
factory)<br />
(fixtures<br />
supplied in<br />
nominal 1’<br />
increments only)<br />
T8 32W<br />
T5 28W<br />
T5HO 54W<br />
LED30K* 3000k<br />
LED35K* 3500k<br />
LED40K* 4000k<br />
*available with opal satin lens only<br />
N<br />
None<br />
OL<br />
Opal<br />
Satin<br />
Lens<br />
Control<br />
Down<br />
SL<br />
Specular<br />
Parabolic<br />
Louver<br />
SSL<br />
Semi<br />
Specular<br />
Parabolic<br />
Louver<br />
OL<br />
Opal Satin<br />
Lens<br />
A<br />
Asymmetrical<br />
reflector<br />
(single T5,<br />
T5HO, T8 only)<br />
Mounting Ballast Circuitry Voltage Options<br />
Pendant<br />
Y<br />
Yoke<br />
Aircraft<br />
Cable<br />
W<br />
Wall<br />
Finish<br />
A Anodized<br />
Aluminum<br />
C Custom<br />
For custom<br />
Finish specify<br />
RAL#<br />
Standard<br />
E<br />
Electronic Instant Start T8<br />
Programmed Rapid Start -T5/T5HO<br />
Dimming 120V/277V Dimming<br />
D1 Advance Mark 7<br />
(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />
D2 Advance Mark 10<br />
(1/2 Lamp T8, 1/2 Lamp T5HO)<br />
D4 Lutron Hi-lume<br />
(1/2 Lamp T8, T5HO)<br />
D5 Lutron Eco-<strong>System</strong><br />
(T5-T5HO-T8) (347V available)<br />
(some lamp/ballast cominations may not be<br />
available — consult factory for availability)<br />
Battery Pack Options<br />
BN1 Bodine B50LP (T8)<br />
BN2 Bodine LP400 (T8)<br />
BN3 Bodine LP500 (T5)<br />
BN4 Bodine LP600 (T5/T5HO/T8)<br />
1<br />
1 Circuit<br />
(Standard)<br />
AB*<br />
Alternating<br />
Switching<br />
EN*<br />
Emergency/<br />
Night Light<br />
LED Driver<br />
/LR*<br />
Left-right<br />
Switching<br />
*n/a for LED<br />
120<br />
277<br />
347*<br />
*(not<br />
available<br />
for LED)<br />
N<br />
None<br />
D<br />
Daylight<br />
Sensor<br />
O<br />
Occupancy<br />
Sensor<br />
DOS<br />
Daylight/<br />
Occupancy<br />
Sensor<br />
Maximum fixture lumens/foot<br />
Standard Dimming 3000k 3500k 4000k<br />
S350 (350mA) D350 (350mA) 959 1019 1065<br />
S700 (700mA) D700 (700mA) 1918 2038 2130<br />
Approvals<br />
R1-07-12<br />
570 Southgate Drive, Guelph, Ontario N1G 4P6<br />
Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />
T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />
www.metalumen.com<br />
(UO) Signature Straub Hall - Deferred Maintenance<br />
Type P<br />
Metalumen: RM4DI-2-T8-4-OL-OL-Y-E-1-277-N<br />
Northern Date Illumination Company<br />
3
TYPE P<br />
Ordering Guide<br />
SPECIFICATIONS<br />
Grande RM4DI<br />
Series<br />
T8, T5, T5H0 DIRECT/IDIRECT – Pendant, Wall<br />
TAB<br />
15<br />
CONSTRUCTION SPECIFICATIONS<br />
T8, T5, T5HO<br />
LED<br />
HOUSING<br />
Rigid extruded aluminum body, 2.0mm [0.08”]<br />
nominal wall thickness. 95mm [3.7”] width x 135mm<br />
[5.3”] high<br />
End Caps: C.R.S.<br />
FINISH<br />
Anodized aluminum, Custom finishes available.<br />
LIGHTING CONTROL OPTIONS<br />
Specular or semi specular parabolic louvre<br />
High transmittance snap in satin lens<br />
Asymmetrical reflector — single lamp only — open<br />
bottom<br />
MOUNTING<br />
PENDANT<br />
Steel aircraft cable yoke complete with a Quick-Grip<br />
field adjustable suspension system provides for quick<br />
and easy onsite alignment.<br />
135 [5.3]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
135 [5.3]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
1<br />
WALL<br />
Wall brackets supplied<br />
106 [4.2]<br />
106 [4.2]<br />
LED/DRIVER SPECIFICATIONS<br />
Medium power LED’s<br />
Color temperatures available: 3000K, 3500K, 4000K<br />
CRI: 84 (4000k) (80 minimum)<br />
Nominal power consumption: 15W - 700mA, 7.5W -<br />
350mA<br />
Hours: 50,000<br />
Maximum delivered lumens/foot:<br />
350mA<br />
3000K 959 lm/ft<br />
3500K 1019 lm/ft<br />
4000K 1065 lm/ft<br />
700mA<br />
3000K 1918 lm/ft<br />
3500K 2038 lm/ft<br />
4000K 2130 lm/ft<br />
Voltage: 120V or 277V input voltage.<br />
Heat Sink: Extruded Aluminum Profile<br />
LED connections: Board mounted connectors.<br />
Drivers: available from several manufacturers.<br />
Drivers matched to run lengths and specific LED light<br />
engines.<br />
135 [5.3]<br />
Wall<br />
91 [3.6]<br />
95 [3.7]<br />
135 [5.3]<br />
Wall<br />
91 [3.6]<br />
95 [3.7]<br />
Certification<br />
Testing Standards: Tested in accordance with IESL-<br />
M79-08<br />
RoHS Compliant<br />
Warranty: 3 year<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type P<br />
Metalumen: RM4DI-2-T8-4-OL-OL-Y-E-1-277-N<br />
Northern Illumination Company<br />
4<br />
R1-07-12
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Portfolio, LD4 Series<br />
Section 26500 Type: SA<br />
PROPOSED SUBSTITUTION: Omega, OM4LED28277-R4LED40KHZ<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
By Jesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
application<br />
<br />
Philips Omega Revelation LED downlight utilizes<br />
proprietary remote phosphor technology to produce<br />
one of the most efficient and advanced LED systems<br />
available for general illumination.<br />
light engine<br />
<br />
<br />
<br />
<br />
<br />
<br />
phosphor technology provides increased efficiency<br />
and color stability by redirecting back reflected light.<br />
The phosphor lens assembly converts high brightness<br />
blue light into white light for an even diffused pattern,<br />
eliminating bright spots often created by individual LEDs.<br />
This technology provides consistent, stable color with<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
supply is overload and short circuit protected as well<br />
as thermally regulated to prevent overheating. Sound<br />
<br />
<br />
hours.<br />
<br />
<br />
construction<br />
<br />
<br />
heat sink allows for easy and tool less installation to<br />
the housing yoke. The heat sink is designed to properly<br />
<br />
applications to provide reliable performance over the life<br />
of the light engine. The heat sink incorporates alignment<br />
tabs to properly position with the housing. Rust resistant<br />
springs are used to secure the reflector to the light<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
". Yoke supports weight of heat sink<br />
and light engine assembly to prevent stress on finished<br />
reflector.<br />
<br />
are self flanged and snap to heat sink for consistent<br />
<br />
visual cutoff to source and source image.<br />
<br />
provide vertical and horizontal adjustments. These allow<br />
<br />
" <br />
alignment in 24" O.C. grid systems.<br />
<br />
<br />
inspection below ceiling.<br />
<br />
maintenance of complete system below ceiling.<br />
Removing reflector provides easy access to heat sink and<br />
light engine assembly. This assembly may be removed by<br />
depressing the springs which attach to the yoke and then<br />
simply opening protective cover and unplugging the push<br />
in connector from the LED board.<br />
listings & warranty<br />
TYPE SA<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
4" LED 1500 Lumen Downlight<br />
Project<br />
Type<br />
<br />
Comments<br />
<br />
RV11-6.1<br />
<br />
<br />
<br />
<br />
<br />
<br />
–<br />
R4LED<br />
Family<br />
OM4LED<br />
<br />
Wattage<br />
Voltage<br />
120 <br />
<br />
277 <br />
<br />
347 Stepdown<br />
<br />
Option<br />
28 EM – Bodine<br />
<br />
Backup <br />
<br />
– 4" Reflector<br />
CCT<br />
<br />
<br />
<br />
<br />
CS – Clear Specular<br />
CSS <br />
Specular<br />
HZ <br />
GS <br />
WT <br />
PW – Pewter<br />
BZ – Bronze<br />
WH <br />
FF – Finish Flange<br />
<br />
<br />
in emergency mode <br />
<br />
Lumen output varies depending on CCT.<br />
<br />
<br />
<br />
<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type SA<br />
Omega: OM4LED28277-R4LED40KHZ<br />
Northern Illumination Company
RV11-6.1<br />
<br />
TYPE SA<br />
4" LED 1500 Lumen Downlight<br />
energy data<br />
<br />
<br />
<br />
<br />
dimensions<br />
24-15/16"<br />
(633.7mm)<br />
C<br />
C<br />
6-3/16"<br />
(152.4mm)<br />
10"<br />
(254.7mm)<br />
4-1/2"<br />
(115.1mm)<br />
5-1/8"<br />
(130.1mm)<br />
5-13/16"<br />
(146.9mm)<br />
1-15/16"<br />
(33.7mm)<br />
photometrics<br />
OM4LED28120-R4LED35KCS<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Comp Yearly Energy Cost at<br />
<br />
<br />
45 Cross<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
45 Cross<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
pw <br />
RCR<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
www.omegalighting.com<br />
Canadian Division<br />
<br />
<br />
<br />
Specifications are subject to change without notice.<br />
<br />
lamps that contain small amounts of mercury. Such lamps are labeled,<br />
<br />
mercury must be disposed of in accordance with local requirements.<br />
<br />
www.lamprecycle.org<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type SA<br />
Omega: OM4LED28277-R4LED40KHZ<br />
Northern Illumination Company
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Portfolio, LD6 Series<br />
Section 26500 Type: SA1<br />
PROPOSED SUBSTITUTION: Omega, OM6LEDXX277DL-R6LED40KHZDL<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
By Jesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
application<br />
<br />
Philips Omega Revelation LED downlight utilizes the<br />
proprietary remote phosphor technology to produce<br />
one of the most efficient and advanced LED systems<br />
available for general illumination in retail, hospitality,<br />
office and institutional applications.<br />
light engine<br />
<br />
<br />
<br />
<br />
<br />
<br />
phosphor technology provides increased efficiency<br />
and color stability by redirecting back reflected light.<br />
Phosphor lens assembly converts high brightness royal<br />
blue light into white light for an even, diffused pattern,<br />
eliminating bright spots often created by individual LEDs.<br />
This technology provides consistent, stable color with<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
circuit protected as well as thermally regulated to<br />
<br />
<br />
visit www.lutron.com.<br />
<br />
<br />
construction<br />
<br />
<br />
<br />
the housing yoke. The heat sink is designed to properly<br />
<br />
applications to provide reliable performance over the life<br />
of the light engine. The heat sink incorporates alignment<br />
tabs to properly position with the housing. Rust resistant<br />
springs are used to secure the reflector to the light<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
and light engine assembly to prevent stress on finished<br />
reflector.<br />
<br />
<br />
of finishes available. White flange is standard. Optional<br />
<br />
to the catalog number. Optics are designed to provide a<br />
<br />
<br />
included and provide vertical and horizontal adjustments.<br />
These allow for fast and adjustment free installation in<br />
<br />
<br />
<br />
<br />
inspection below ceiling.<br />
<br />
maintenance of complete system below ceiling.<br />
Removing reflector provides easy access to heat sink and<br />
light engine assembly. This assembly may be removed<br />
<br />
then simply opening protective cover and unplugging the<br />
push in connector from the LED board.<br />
listings & warranty<br />
<br />
<br />
<br />
TYPE SA1<br />
<br />
<br />
<br />
<br />
<br />
<br />
Project<br />
Type<br />
<br />
Comments<br />
<br />
6" LED<br />
2000 Lumen Downlight<br />
with Lutron Hi Lume A Series<br />
<br />
RV11-11.1<br />
<br />
<br />
<br />
<br />
<br />
DL<br />
–<br />
<br />
DL<br />
Family<br />
OM6LED<br />
<br />
Wattage<br />
40 2<br />
27 <br />
20 4<br />
Voltage<br />
120 <br />
<br />
277 <br />
<br />
347 <br />
<br />
Driver<br />
<br />
<br />
Option<br />
EM – <br />
<br />
<br />
<br />
CCT<br />
<br />
<br />
<br />
<br />
CS <br />
CSS <br />
<br />
HZ <br />
GS <br />
WT – Wheat<br />
PW – Pewter<br />
BZ <br />
WH – White, Paint<br />
FF <br />
<br />
Dimming<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Lumen output varies depending on CCT,<br />
<br />
<br />
<br />
<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type SA1<br />
Omega: OM6LEDXX277DL-R6LED40KHZDL<br />
Northern Illumination Company
RV11-11.1 <br />
TYPE SA1<br />
6" LED 2000 Lumen Downlight<br />
energy data<br />
<br />
<br />
<br />
<br />
dimensions<br />
24-15/16"<br />
(633.7mm)<br />
A<br />
A<br />
7-1/8"<br />
(180.7mm)<br />
9-1/2"<br />
(228.6mm)<br />
ceiling<br />
cutout<br />
6"<br />
(151.8mm)<br />
6-3/8"<br />
(161.9mm)<br />
7-5/8"<br />
1-3/8"<br />
(34.9mm)<br />
photometrics<br />
OM6LED40120DL-R6LED30KCSDL<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
45 Cross<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
45 Cross<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
RCR<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
www.omegalighting.com<br />
Canadian Division<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
mercury must be disposed of in accordance with local requirements.<br />
<br />
www.lamprecycle.org<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type SA1<br />
Omega: OM6LEDXX277DL-R6LED40KHZDL<br />
Northern Illumination Company
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Winona, Step Series<br />
Section 26500 Type: SB<br />
PROPOSED SUBSTITUTION: Gardco, 941L-20LA-C-DG-NW-UNVI-BRP<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
By Jesse Smith - Glumac Lighting Studio<br />
Date: 5/7/13<br />
Date 5/20/2013<br />
Frosted glass is not preferred. LEDs<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks<br />
need to be more discrete.<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
Job:<br />
Type:<br />
Notes:<br />
Page 1 of 3<br />
TYPE SB<br />
94 Line LED<br />
941L, 942L and 943L Step and Aisle Lights<br />
941L<br />
The Philips Gardco 941L, 942L and 943L recessed aisle lights are architecturally styled luminaires<br />
precisely constructed of die cast aluminum, providing light with high performance, long life LED systems.<br />
Retrofit kits are also available, making it possible to update installations of classic 941, 942 and 943<br />
Philips Gardco fluorescent and HID step lights to LED without the need to replace the back housing. A<br />
field adjustable junction box enhances design flexibility. Self-compensating silicone gasketing completely<br />
excludes moisture, insects and contaminants. A choice of three (3) architecturally designed faceplates<br />
allows for a variety of applications. The ribbed guard faceplate offers vandal protection for glass lenses.<br />
942L<br />
943L<br />
943L<br />
Mounted<br />
in Bollard<br />
PREFIX<br />
WALL TYPE<br />
FACEPLATE<br />
LED<br />
WATTAGE<br />
LED<br />
SELECTION VOLTAGE FINISH OPTIONS<br />
Enter the order code into the appropriate box above. Omit WALL TYPE for 943L-B25 and 943L-B40. Note: Philips Gardco reserves the right to refuse a configuration. Not all<br />
combinations and configurations are valid. Refer to notes below for exclusions and limitations. For questions or concerns, please consult the factory.<br />
PREFIX<br />
Complete Luminaires<br />
941L 1 Horizontal<br />
942L Horizontal<br />
943 L Vertical<br />
943L-B25 943L Mounted in 25" Bollard<br />
943L-B40 943L Mounted in 40" Bollard<br />
Retrofit Kits 1<br />
RK-941L 1,2 Horizontal<br />
RK-942L 2 Horizontal<br />
RK-943L 2 Vertical<br />
LED WATTAGE with LUMEN DATA<br />
WALL TYPE<br />
D Drywall<br />
Not suitable for concrete pour applications. Also,<br />
if insulating material is present, it must be kept<br />
at least 3" away from luminaire. Type D units are<br />
thermally protected. Non-IC luminaire.<br />
C Concrete Pour<br />
Suitable for concrete pour applications only.<br />
NOTE: WALL TYPE does not apply to<br />
943L-B25 and 943L-B40. Omit WALL TYPE for<br />
943L-B25 and 943L-B40.<br />
FACEPLATES<br />
LV Louver<br />
DG 1 Diffuse Glass<br />
RGD 1 Ribbed Guard with Diffuse Glass<br />
1. 941L and RK-941L are not available with the RGD faceplate.<br />
2. Retrofit kits are available in Wall Type “C” only (Concrete Pour.) Retrofit<br />
kits are not available for existing Wall Type “D” (Drywall) luminaires. The<br />
step light portion of existing 943BL25 and 943BL40 units may be<br />
replaced utilizing RK-943L retrofit kits.<br />
Back housings for concrete pour applications (Type C) are available for<br />
pre-shipment. Contact factory for details.<br />
Order<br />
Code<br />
Description<br />
LED<br />
Current<br />
(mA)<br />
Average<br />
<strong>System</strong><br />
Watts 3<br />
LED<br />
Selection<br />
Absolute Initial Luminaire Lumens 4<br />
941 942 943<br />
Faceplate Faceplate Faceplate<br />
LV DG LV DG RGD LV DG RGD<br />
20LA<br />
20 watt,<br />
LED integral lens array.<br />
350 20<br />
CW 64 (s) 564 (s) 124 (s) 652 (s) 220 (s) 123 (s) 596 (s) 222 (s)<br />
NW 60 538 118 621 209 117 568 (s) 211 (s)<br />
31LA<br />
31 watt,<br />
LED integral lens array.<br />
530 31<br />
CW 90 (s) 749 (s) 167 (s) 838 (s) 306 (s) 169 (s) 808 (s) 301 (s)<br />
NW 85 713 159 798 292 161 770 (s) 286 (s)<br />
40LA 5<br />
40 watt,<br />
LED integral lens array.<br />
700 40<br />
CW See Note 5 See Note 5 221 1132 407 207 (s) 1010 (s) 376 (s)<br />
NW See Note 5 See Note 5 191 1063 357 197 962 358<br />
3. <strong>System</strong> input wattage may vary based on input voltage, by up to +/- 10% , and based on manufacturer forward voltage, by up to +/- 8%.<br />
4. Lumen values based on photometric tests performed in compliance with IESNA LM-79. Values are for luminaires with a white faceplate. Values will vary based on faceplate color chosen.<br />
Contact Gardco.Applications@philips.com for values not shown above.<br />
5. 941L is not available in 40LA (700mA) LED wattage. Lumen values shown are based on Bronze painted faceplates. Values will vary based on the faceplate color.<br />
(s) indicates values are scaled value based on tests of similar, but not identical, luminaire configurations.<br />
(UO) 1611 Clovis Straub Barker Hall Road, - Deferred San Marcos, Maintenance<br />
TX 78666<br />
Type (800) 227-0758 SB (512) 753-1000 FAX: (512) 753-7855 sitelighting.com<br />
Gardco: © 2012 Koninklijke 941L-20LA-C-DG-NW-UNVI-BRP<br />
Philips Electronics N.V. All Rights Reserved.<br />
Philips Gardco reserves the right to change materials or modify the design of its product without<br />
Northern Illumination Company<br />
notification as part of the company’s continuing product improvement program.<br />
G200-040/1212
Page 2 of 3<br />
LED SELECTION<br />
CW<br />
NW<br />
WW<br />
AM<br />
5,700°K , 75CRI<br />
4,000°K , 70CRI<br />
3,000°K , 80CRI<br />
Amber<br />
VOLTAGE<br />
120 6<br />
277 6<br />
UNIV 7<br />
6. Wall Type D luminaires only.<br />
7. UNIV means120V through 277V<br />
input. Not available on<br />
Wall Type D luminaires.<br />
94 Line LED<br />
941L, 942L and 943L Step and Aisle Lights<br />
FINISH<br />
BLP Black Paint<br />
BRP Bronze Paint<br />
WP White Paint<br />
NP Natural Aluminum Paint<br />
OC<br />
SC<br />
TYPE SB<br />
Optional Color Paint<br />
(Specify RAL designation. ex: OC-RAL7024)<br />
Special Color Paint<br />
(Specify. Must supply color chip)<br />
OPTIONS<br />
F<br />
TP Tamper Resistant Screws<br />
SPR 8 Surge Protection -<br />
120V through 277V -<br />
meeting ANSI C62.41.2<br />
Fusing (Provide specific input voltage.)<br />
8. Not available with Fusing (F) option.<br />
DIMENSIONS<br />
941L Dimensions<br />
12.00"<br />
30.48 12" cm<br />
3.25"<br />
8.26 3.25" cm<br />
(DG) Diffuse Glass<br />
6.75"<br />
17.15 6.75" cm<br />
3.50" 3.5"<br />
8.89 cm<br />
(LV) Louver<br />
2.75"<br />
6.99<br />
2.75"<br />
cm<br />
6.00"<br />
15.24 cm 6"<br />
942L Dimensions<br />
943L Dimensions<br />
13"<br />
(33 cm)<br />
8.5" (21.6 cm)<br />
5.5"(14 cm)<br />
5.5"(14 cm)<br />
5.5"<br />
(14 cm)<br />
5.5"<br />
(14 cm)<br />
13"<br />
(33 cm)<br />
15.8" (40.1 cm)<br />
40.1"<br />
(101.7 cm)<br />
24.6"<br />
(62.5 cm)<br />
8.5" (21.6 cm)<br />
5.5" (14 cm)<br />
5"<br />
(12.7cm)<br />
8" (20.3 cm)<br />
8.5"<br />
(21.6 cm)<br />
943L-B40<br />
8.5"<br />
(21.6 cm)<br />
943L-B25<br />
1611 Clovis Barker Road, San Marcos, TX 78666<br />
(800) 227-0758 (512) 753-1000 FAX: (512) 753-7855 sitelighting.com<br />
(UO) © 2012 Straub Koninklijke Hall Philips - Deferred Electronics N.V. Maintenance<br />
All Rights Reserved.<br />
Type Philips Gardco SB reserves the right to change materials or modify the design of its product without<br />
Gardco: notification 941L-20LA-C-DG-NW-UNVI-BRP<br />
as part of the company’s continuing product improvement program.<br />
Northern G200-040/1212 Illumination Company
Page 3 of 3<br />
SPECIFICATIONS<br />
TYPE SB<br />
GENERAL: The Philips Gardco 941L, 942L and 943L recessed aisle lights are<br />
architecturally styled luminaires precisely constructed of die cast aluminum,<br />
providing light with high performance, long life LED systems. A field adjustable<br />
junction box enhances design flexibility. Self-compensating silicone gasketing<br />
completely excludes moisture, insects and contaminants. A choice of three<br />
(3) architecturally designed faceplates allows for a variety of applications. The<br />
ribbed guard faceplate offers vandal protection for glass lenses.<br />
RETROFIT KITS: Retrofit kits are also available, making it possible to update<br />
installations of classic 941, 942 and 943 Philips Gardco fluorescent and HID step<br />
lights to LED without the need to replace the back housing. Retrofit kits are<br />
available in Wall Type “C” only (Concrete Pour.) Retrofit kits are not available<br />
for existing Wall Type “D” (Drywall) luminaires. The step light portion of<br />
existing 943BL25 and 943BL40 units may be replaced utilizing RK-943L retrofit<br />
kits.<br />
FACEPLATE: All faceplates are constructed of one piece die cast aluminum<br />
and are secured to the housing with two (2) recessed and captive hex<br />
head socket screws. Integral spring clips ensure positive grounding. Selfcompensating<br />
single-piece silicone gasketing completely seals the luminaire and<br />
allows for varying wall thicknesses.<br />
94 Line LED<br />
941L, 942L and 943L Step and Aisle Lights<br />
THERMAL MANAGEMENT: Philips Gardco 94 Line LED step and aisle<br />
lights include integral thermal control to provide the excellent thermal<br />
management so critical to long LED system life.<br />
Electrical: Luminaires are equipped with an LED driver that accepts 120V<br />
through 277V, 50hz to 60hz, input (Wall Type C) , or with specific 120V or<br />
277V input voltages (Wall Type D). Driver output is based on the LED wattage<br />
selected. Component-to-component wiring within the luminaire will carry no<br />
more than 80% of rated current and is listed by UL for use at 600 VAC at 302°F<br />
/ 150°C or higher. Plug disconnects are listed by UL for use at 600 VAC, 15A or<br />
higher. Power factor is not less than 90%. Luminaire consumes 0.0 watts in the<br />
off state.<br />
FINISH: Each standard color luminaire receives a fade and abrasion resistant,<br />
electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC)<br />
textured polyester powdercoat finish. Standard colors include bronze (BRP),<br />
black (BLP), white (WP), and natural aluminum (NP). Consult factory for specs<br />
on optional or custom colors.<br />
LABELS: All luminaires bear UL or CUL (where applicable) Wet Location<br />
labels.<br />
LOUVER: Die cast louvers span the entire length of the faceplate, providing<br />
for vandal resistance and glare control. Louver faceplate include diffuse glass<br />
behind the louvers to minimize apparent glare from the luminaire.<br />
DIFFUSE GLASS: The faceplate includes a 3/16" thick diffuse white opal flat<br />
tempered glass lens. The lens is internally sealed and mounted and provides a<br />
soft, uniform glow.<br />
WARRANTY: Philips Gardco luminaires feature a 5 year limited warranty.<br />
Philips Gardco LED luminaires feature a 5 year limited warranty covering the<br />
LED arrays and LED drivers. See Warranty Information on www.sitelighting.com<br />
for complete details and exclusions.<br />
RIBBED GUARD: 90° die cast louvers span the entire length of the faceplate<br />
over a diffuse glass lens. Not available in the 941L and RK-941L.<br />
HOUSING: The housing is corrosion-resistant die cast aluminum.<br />
J-BOX: The field convertible junction box is die cast aluminum. It is shipped<br />
factory-mounted to the back of housing. The box can be easily positioned<br />
on the bottom of the luminaire via two (2) phillips head screws. Each J-box<br />
includes three (3) threaded openings (one on each side and one on the bottom)<br />
that accommodate 3/4” conduit.<br />
LED RELIABILITY:<br />
PREDICTED LUMEN DEPRECIATION DATA<br />
Ambient Temperature °C Driver mA L 70 Hours 9<br />
25 °C<br />
40 °C<br />
350 mA 180,000<br />
530 mA 115,000<br />
700 mA 95,000<br />
350 mA 175,000<br />
530 mA 100,000<br />
700 mA 90,000<br />
9 Predicted performance derived from LED manufacturer’s data and engineering design estimates,<br />
based on IESNA LM-80 methodology. Actual experience may vary due to eld application<br />
conditions. L 70 is the predicted time when LED performance depreciates to 70% of initial<br />
lumen output.<br />
1611 Clovis Barker Road, San Marcos, TX 78666<br />
(UO) Straub Hall - Deferred Maintenance<br />
(800) 227-0758 (512) 753-1000 FAX: (512) 753-7855 sitelighting.com<br />
Type SB<br />
© 2012 Koninklijke Philips Electronics N.V. All Rights Reserved.<br />
Gardco: 941L-20LA-C-DG-NW-UNVI-BRP<br />
Philips Gardco reserves the right to change materials or modify the design of its product without<br />
Northern Illumination Company<br />
notification as part of the company’s continuing product improvement program.<br />
G200-040/1212
SUBSTITUTION REQUEST<br />
TO: Rowell Brokaw Architects<br />
PROJECT: <strong>University</strong> of <strong>Oregon</strong> (UO) Straub Hall - Deferred Maintenance<br />
SPECIFIED ITEM: Bartco, IPR8MS Series<br />
Section 26500 Type: V1<br />
PROPOSED SUBSTITUTION: Metalumen, RM4D-2-T8-4-OL-S-X-E-1-277-N<br />
Attached data includes product description, specifications, drawings, photographs, performance and test<br />
data adequate for evaluation of request including identification of applicable data portions.<br />
Attached data also includes description of changes to Contract Documents and proposed substitution<br />
requires for proper installation.<br />
Undersigned certifies following items, unless modified by attachments, are correct:<br />
1. Proposed substitution does not affect dimensions shown on drawings.<br />
2. Undersigned pays for changes to building design, including engineering design, detailing, and<br />
construction costs caused by proposed substitution.<br />
3. Proposed substitution has no adverse effect on other trades, construction schedule, or specified warranty<br />
requirements.<br />
4. Maintenance and service parts available locally or readily obtainable for proposed substitution.<br />
Undersigned further certifies function, appearance, and quality of proposed substitution<br />
are equivalent or superior to specified item.<br />
Undersigned agrees, if this page is reproduced, terms and conditions for substitutions<br />
found in Bidding Documents apply to this proposed substitution.<br />
Submitted by:<br />
Name (Printed or typed)<br />
David Wray<br />
General Contractor (if after award of Contract)<br />
For use by A/E<br />
Signature<br />
Firm Name: Northern Illumination Co. Inc. Approved Approved as noted<br />
Address: 17400 SW Upper Boones Ferry Rd. #270 Not Approved Received too late<br />
City, State, Zip: Portland, OR 97224<br />
Date: 5/7/13<br />
By Jesse Smith - Glumac Lighting Studio<br />
Date 5/20/2013<br />
Tel: (503) 226-3633 Fax: (503) 226-3733 Remarks Fixture must have wrap lens<br />
The Construction Specifications Institute September 1997<br />
Northwest Region
TYPE V1<br />
Ordering Guide<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
106 [4.2]<br />
102 [4.0]<br />
119 [4.7]<br />
119 [4.7]<br />
102 [4.0]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Part number example<br />
91 [3.6]<br />
115 [4.5]<br />
91 [3.6]<br />
120 [4.7]<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant Recessed Drywall Recessed T-bar Surface Wall<br />
91 [3.6]<br />
95 [3.7]<br />
Dimensions and photometry see reverse.<br />
RM4D 2S T5 12 N SL RD A E 1 347 N<br />
Model<br />
RM4D<br />
Number of<br />
Lamps<br />
Lamp<br />
Type<br />
Length<br />
Control<br />
Up<br />
N<br />
Control<br />
Down<br />
Mounting<br />
Finish<br />
Ballast<br />
Driver<br />
Circuitry Voltage Options<br />
No. of Lamps Length Control Up<br />
1<br />
1 Lamp<br />
1S<br />
1<br />
Staggered*<br />
1L<br />
1 LED<br />
2<br />
2 Lamps*<br />
2S<br />
2<br />
Staggered*<br />
*(T8 with opal<br />
satin lens<br />
only)<br />
Lamp Type<br />
4<br />
4 Foot<br />
8<br />
8 Foot<br />
12<br />
12 Foot<br />
R<br />
Continuous<br />
Length<br />
(consult<br />
factory)<br />
(fixtures<br />
supplied in<br />
nominal 1’<br />
increments only)<br />
T8 32W<br />
T5 28W<br />
T5HO 54W<br />
LED30K* 3000k<br />
LED35K* 3500k<br />
LED40K* 4000k<br />
*available with opal satin lens only<br />
N<br />
None<br />
Control<br />
Down<br />
SL<br />
Specular<br />
Parabolic<br />
Louver<br />
SSL<br />
Semi<br />
Specular<br />
Parabolic<br />
Louver<br />
OL<br />
Opal Satin<br />
Lens<br />
A<br />
Asymmetrical<br />
reflector<br />
(single T5,<br />
T5HO, T8 only)<br />
Mounting Ballast Circuitry Voltage Options<br />
Pendant<br />
Y<br />
Yoke Aircraft<br />
Cable<br />
RT<br />
Recessed<br />
T-Bar<br />
RD<br />
Recessed<br />
Drywall<br />
S<br />
Surface<br />
W<br />
Wall<br />
Finish<br />
A<br />
Anodized<br />
Aluminum<br />
C<br />
Custom<br />
For custom<br />
Finish specify<br />
RAL#<br />
Standard<br />
E<br />
Electronic Instant Start T8<br />
Programmed Rapid Start -T5/T5HO<br />
Dimming 120V/277V Dimming<br />
D1 Advance Mark 7<br />
(1/2 Lamp T8, 1/2 Lamp T5/T5HO)<br />
D2 Advance Mark 10<br />
(1/2 Lamp T8, 1/2 Lamp T5HO)<br />
D4 Lutron Hi-lume<br />
(1/2 Lamp T8, T5HO)<br />
D5 Lutron Eco-<strong>System</strong><br />
(T5-T5HO-T8) (347V available)<br />
(some lamp/ballast cominations may<br />
not be available — consult factory for<br />
availability)<br />
Battery Pack Options<br />
BN1 Bodine B50LP (T8)<br />
BN2 Bodine LP400 (T8)<br />
BN3 Bodine LP500 (T5)<br />
BN4 Bodine LP600 (T5/T5HO/T8)<br />
1<br />
1 Circuit<br />
(Standard)<br />
AB*<br />
Alternating<br />
Switching<br />
EN*<br />
Emergency/<br />
Night Light<br />
LED Driver<br />
/LR*<br />
Left-right<br />
Switching<br />
*n/a for LED<br />
120<br />
277<br />
347*<br />
*(not<br />
available<br />
for LED)<br />
N<br />
None<br />
D<br />
Daylight<br />
Sensor<br />
O<br />
Occupancy<br />
Sensor<br />
DOS<br />
Daylight/<br />
Occupancy<br />
Sensor<br />
Maximum fixture lumens/foot<br />
Standard Dimming 3000k 3500k 4000k<br />
S350 (350mA) D350 (350mA) 480 510 533<br />
S700 (700mA) D700 (700mA) 959 1019 1065<br />
Approvals<br />
R1-07-12<br />
570 Southgate Drive, Guelph, Ontario N1G 4P6<br />
Mailing Address: P.O. Box 1779, Guelph, Ontario N1H 629<br />
T: 800.621.6785 T: 519.822.4381 F: 519.822.4589<br />
www.metalumen.com<br />
(UO) Signature Straub Hall - Deferred Maintenance<br />
Type V1<br />
Metalumen: RM4D-2-T8-4-OL-S-X-E-1-277-N<br />
Northern Date Illumination Company<br />
1
TYPE V1<br />
Ordering Guide<br />
SPECIFICATIONS<br />
T8, T5, T5H0<br />
Grande RM4D<br />
Series<br />
DIRECT – Pendant, Recessed, Surface, Wall<br />
TAB<br />
15<br />
CONSTRUCTION SPECIFICATIONS<br />
HOUSING<br />
Rigid extruded aluminum body, 2.0mm [0.08”]<br />
nominal wall thickness. 95mm [3.7”] width x 102mm<br />
[4.0”] high (Pendant/Wall/Surface)<br />
115mm [4.5”] width x 119mm [4.7”] high (Recessed)<br />
End Caps: C.R.S.<br />
FINISH<br />
Anodized aluminum, Custom finishes available.<br />
T8, T5, T5HO<br />
102 [4.0]<br />
LED<br />
102 [4.0]<br />
LIGHTING CONTROL OPTIONS<br />
Specular or semi specular parabolic louvre<br />
High transmittance snap in satin lens<br />
Asymmetrical reflector — single lamp only — open<br />
bottom<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
91 [3.6]<br />
95 [3.7]<br />
Pendant<br />
MOUNTING<br />
PENDANT<br />
Steel aircraft cable yoke complete with a Quick-Grip<br />
field adjustable suspension system provides for quick<br />
and easy onsite alignment.<br />
119 [4.7]<br />
119 [4.7]<br />
RECESSED<br />
T-Bar — Mounting clips supplied<br />
Drywall — Mounting brackets supplied<br />
WALL<br />
Wall brackets supplied<br />
SURFACE<br />
Direct to surface mount<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
91 [3.6]<br />
115 [4.5]<br />
Recessed Drywall<br />
LED/DRIVER SPECIFICATIONS<br />
Medium power LED’s<br />
Color temperatures available: 3000K, 3500K, 4000K<br />
CRI: 84 (4000K) (80 minimum)<br />
Nominal power consumption: 15W - 700mA, 7.5W -<br />
350mA<br />
Hours: 50,000<br />
Maximum delivered lumens/foot:<br />
350mA<br />
3000K 480 lm/ft<br />
3500K 510 lm/ft<br />
4000K 533 lm/ft<br />
700mA<br />
3000K 959 lm/ft<br />
3500K 1019 lm/ft<br />
4000K 1065 lm/ft<br />
Voltage: 120V or 277V input voltage.<br />
Heat Sink: Extruded Aluminum Profile<br />
LED connections: Board mounted connectors.<br />
Drivers: available from several manufacturers.<br />
Drivers matched to run lengths and specific LED light<br />
engines.<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
119 [4.7]<br />
91 [3.6]<br />
120 [4.7]<br />
Recessed T-bar<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
Surface<br />
106 [4.2]<br />
Certification<br />
Testing Standards: Tested in accordance with IESL-<br />
M79-08<br />
RoHS Compliant<br />
Warranty: 3 year<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
102 [4.0]<br />
91 [3.6]<br />
95 [3.7]<br />
(UO) Straub Hall - Deferred Maintenance<br />
Type V1<br />
Metalumen: RM4D-2-T8-4-OL-S-X-E-1-277-N<br />
Northern Illumination Company<br />
2<br />
Wall<br />
Wall<br />
R1-07-12
Jesse Smith - Glumac Lighting Studio<br />
5/20/2013<br />
Please provide a sample<br />
of this fixture series.
Jesse Smith - Glumac Lighting Studio<br />
5/20/2013<br />
Please provide a sample<br />
of this fixture series.
Jesse Smith - Glumac Lighting Studio<br />
5/20/2013<br />
Please provide a sample<br />
of this fixture series.
Jesse Smith - Glumac Lighting Studio<br />
5/20/2013
Jesse Smith - Glumac Lighting Studio<br />
5/20/2013<br />
Please provide a sample<br />
of this fixture series.
Straub Hall Window Condition Assessment<br />
May 2011<br />
<strong>University</strong> of <strong>Oregon</strong><br />
Campus Planning & Real Estate
Project Contacts<br />
Liz Carter, Student<br />
Christine Taylor Thompson, Planning Associate<br />
<strong>University</strong> of <strong>Oregon</strong><br />
Campus Planning and Real Estate<br />
1276 <strong>University</strong> of <strong>Oregon</strong><br />
Eugene, <strong>Oregon</strong> 97403-1276<br />
http://uplan.uoregon.edu<br />
(541) 346-5562<br />
Additional information about the history of Straub Hall and campus development is<br />
available on the CPRE website: http://uplan.uoregon.edu/. follow the link to “Planning<br />
documents” and then “Historic Preservation” to find the UO 4.0 Survey of Buildings and the<br />
Heritage Landscape Plan.<br />
Special thank you to Straub Hall Building manager, George Helbling.<br />
Straub Hall Window Condition Assessment - 1
Purpose of Assessment:<br />
Straub Hall was designed in the Colonial Revival style as a men’s dormitory and constructed in 1928-29. The building continued to serve as a<br />
dormitory until 1971 when the process to convert the building for academic purposes was started.<br />
Straub Hall will soon undergo an extensive remodel. Identified as a Deferred Maintenance Project, the Project will implement seismic<br />
upgrades; retrofit or replace existing heating, ventilation, electrical, plumbing, and lighting systems with more energy and water efficient<br />
systems; enhance the thermal performance of the building envelope; and improve accessibility. The purpose of this survey is to assist the<br />
project by assessing the condition of the exterior windows to provide information for decision making associated with window enhancement,<br />
replacement, and/or restoration.<br />
Scope of Assessment:<br />
This survey will be looking at all exterior windows in Straub Hall, including skylights and foundation/basement windows. The scale of<br />
Condition used for this survey is as follows:<br />
EXCELLENT = only superficial damage (like chipping paint)<br />
GOOD = will require some invasive repair to parts but can be restored<br />
FAIR = will require extensive invasive repair to parts to be restored<br />
POOR = window parts are unsalvagable.<br />
Findings of Assessment:<br />
Overall, the assessed Straub Hall windows are in GOOD condition. Most of the damage to the windows is superficial. Areas most affected<br />
are the brick sills and the exterior wood sill/casings’ paint. In areas that have been without proper paint coverage (mainly the south and west<br />
facades), checking of the wood sills has occurred.<br />
General Notes:<br />
Unless otherwise noted all window parts and hardware appear to be original. Most windows in the building, excluding select few that<br />
correspond with staircases or the like, have be designed to be operable. Some of these windows have since become inoperable for various<br />
reasons. Some of these windows are currently considered inoperable but only need new weight cords to be operable. The majority of the<br />
windows on the first, second, and third floors are double hung with wood muntins. The basement windows are mostly double casement<br />
windows or double hung, both with wood muntins. There are four windows that are double height. These are in the staircases stretching<br />
between the third and fourth floors.<br />
Straub Hall Window Condition Assessment - 2
STRAUB WINDOW CONDITION ASSESSMENT<br />
Window Parts Key: J = Jamb, IC = Interior Casing, RS = Rail and Stiles, St = Stool<br />
Indicates that there is a current issue with the window impeding its function<br />
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
024a<br />
025a<br />
028a<br />
028b<br />
028c<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top<br />
double hung<br />
clearstory,<br />
w/wood<br />
muntins<br />
aluminium<br />
slider<br />
clearstories<br />
aluminium<br />
slider<br />
clearstories<br />
aluminium<br />
slider<br />
clearstories<br />
Conditions<br />
Window<br />
Paint<br />
Parts*<br />
excellent excellent NA excellent poor, right<br />
weight cord<br />
broken<br />
Brick Sill<br />
Facing<br />
Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
no good north<br />
fair excellent NA excellent no, painted<br />
into place<br />
excellent excellent excellent,<br />
concrete sill<br />
excellent excellent excellent,<br />
concrete sill<br />
excellent excellent excellent,<br />
concrete sill<br />
030Aa casement good poor, only<br />
casing<br />
remains<br />
no good north<br />
excellent excellent no excellent south yes<br />
excellent excellent no excellent south<br />
excellent excellent no excellent south<br />
NA NA open to<br />
foundations<br />
no<br />
good, but north<br />
no longer<br />
connects to<br />
outdoors<br />
window is now an open<br />
connection to<br />
foundation<br />
yes<br />
030Ab casement good, some<br />
chipping<br />
good NA excellent yes, opens to<br />
foundations<br />
no<br />
good, but north<br />
no longer<br />
connects to<br />
outdoors<br />
window is now a<br />
closable connection to<br />
foundation<br />
yes<br />
Straub Hall Window Condition Assessment - 3
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
051a<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
Conditions<br />
Window<br />
Paint<br />
Parts*<br />
good excellent moss and<br />
debris covered<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
fair, chipped poor, right<br />
but weight cord<br />
functional broken<br />
Facing<br />
Elev. Comments Photo<br />
no fair south only one window is<br />
noted on plans, while<br />
there are two windows<br />
in this room<br />
051b<br />
double hung good<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
large gouges<br />
in top sash<br />
moss and<br />
debris covered<br />
excellent<br />
poor, left<br />
weight cord<br />
broken<br />
no fair south only one window is<br />
noted on plans, while<br />
there are two windows<br />
in this room<br />
Straub Hall Window Condition Assessment - 4
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
105a<br />
109a<br />
109b<br />
109c<br />
109d<br />
109e<br />
double hung,<br />
lower<br />
portion<br />
operable,<br />
with wood<br />
muntins<br />
double hung,<br />
lower<br />
portion<br />
operable,<br />
with wood<br />
muntins<br />
double hung,<br />
lower<br />
portion<br />
operable,<br />
with wood<br />
muntins<br />
double hung,<br />
lower<br />
portion<br />
operable,<br />
with wood<br />
muntins<br />
double hung,<br />
lower<br />
portion<br />
operable,<br />
with wood<br />
muntins<br />
double hung,<br />
lower<br />
portion<br />
operable,<br />
with wood<br />
muntins<br />
Conditions<br />
Paint<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent excellent excellent, yes no excellent south opens into courtyard yes<br />
modified<br />
excellent excellent excellent excellent,<br />
modified<br />
with<br />
secondary<br />
locks<br />
excellent excellent excellent excellent,<br />
modified<br />
with<br />
secondary<br />
locks<br />
excellent excellent excellent excellent,<br />
modified<br />
with<br />
secondary<br />
locks<br />
excellent excellent excellent excellent,<br />
modified<br />
with<br />
secondary<br />
locks<br />
excellent excellent excellent modified<br />
with<br />
secondary<br />
locks,<br />
broken left<br />
weight cord<br />
poor, right<br />
weight cord<br />
broken<br />
no, painted<br />
into place<br />
no, painted<br />
into place<br />
poor, broken<br />
left weight<br />
cord<br />
no excellent east windows new (2001),<br />
they do not open<br />
windows in this room<br />
to control humidity, due<br />
to its proximity to the<br />
MRI.<br />
no excellent east<br />
no excellent east<br />
no excellent north<br />
poor no excellent north<br />
Straub Hall Window Condition Assessment - 5
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
111a<br />
111b<br />
113a<br />
S113a<br />
119a<br />
119b<br />
double hung,<br />
lower<br />
portion<br />
operable.<br />
with wood<br />
muntins<br />
double hung,<br />
lower<br />
portion<br />
operable,<br />
with wood<br />
muntins<br />
double hung,<br />
lower<br />
portion<br />
operable,<br />
with wood<br />
muntins<br />
double hung,<br />
lower<br />
portion<br />
operable,<br />
with wood<br />
muntins<br />
double hung,<br />
lower<br />
portion<br />
operable,<br />
with wood<br />
muntins<br />
double hung,<br />
lower<br />
portion<br />
operable<br />
with wood<br />
muntins<br />
Conditions<br />
Paint<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent excellent modified poor no good north<br />
with<br />
secondary<br />
locks,<br />
broken left<br />
weight cord<br />
excellent excellent excellent excellent, poor, sticky no good north window not on current<br />
modified<br />
drawings<br />
with<br />
secondary<br />
locks<br />
excellent excellent excellent excellent,<br />
modified<br />
with<br />
secondary<br />
locks<br />
excellent excellent excellent none no, not an<br />
operable<br />
window<br />
excellent excellent excellent excellent,<br />
modified<br />
with<br />
secondary<br />
locks<br />
excellent excellent excellent excellent,<br />
modified<br />
with<br />
secondary<br />
locks<br />
yes no excellent north<br />
no excellent south opens into courtyard<br />
yes no excellent south<br />
yes no excellent north<br />
Straub Hall Window Condition Assessment - 6
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
119c<br />
S120a<br />
double hung,<br />
lower<br />
portion<br />
operable<br />
with wood<br />
muntins<br />
fixed wood<br />
window with<br />
muntins<br />
Conditions<br />
Paint<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent excellent excellent, yes no excellent north<br />
modified<br />
with<br />
secondary<br />
locks<br />
excellent excellent excellent none no no excellent east window not on current<br />
plan<br />
122a<br />
double hung excellent excellent good, some<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
moss<br />
accumulation<br />
fair, chipped<br />
but<br />
functional<br />
top window<br />
has been<br />
fixed<br />
no excellent north<br />
122b<br />
double hung excellent excellent good, some<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
moss<br />
accumulation<br />
excellent yes no excellent north<br />
122c<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
excellent excellent excellent excellent top window<br />
has been<br />
fixed<br />
no excellent north<br />
122d<br />
double hung excellent excellent good, some<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
moss<br />
accumulation<br />
fair, chipped<br />
but<br />
functional<br />
yes no excellent west<br />
Straub Hall Window Condition Assessment - 7
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
126a<br />
127a<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
bottom<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
Conditions<br />
Window<br />
Paint<br />
Parts*<br />
excellent excellent excellent fair, chipped<br />
but<br />
functional<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
no longer no excellent,<br />
operable,<br />
but altered<br />
window has<br />
been fixed in<br />
place and<br />
one of the<br />
top panes fit<br />
with a fan<br />
excellent excellent excellent excellent excellent no excellent west<br />
Facing<br />
Elev. Comments Photo<br />
east window diffuse glass, yes<br />
lower one painted<br />
white.<br />
128a<br />
129a<br />
130a<br />
S130a<br />
double hung excellent excellent excellent excellent excellent no excellent east<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
double hung excellent excellent excellent excellent excellent no excellent west Screen on exterior,<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
lower window does not<br />
remain open on its own.<br />
double hung excellent excellent excellent excellent excellent no excellent east has weight cord<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
protectors.<br />
fixed wood excellent excellent excellent none no no excellent east<br />
window with<br />
muntins<br />
Straub Hall Window Condition Assessment - 8
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
131a<br />
131b<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
Conditions<br />
Paint<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
excellent excellent excellent excellent excellent no excellent west With exterior screen.<br />
May had been top<br />
opening as well and<br />
painted in place.<br />
excellent excellent excellent excellent poor, right<br />
weight cord<br />
broken<br />
no excellent west<br />
Facing<br />
Elev. Comments Photo<br />
137a<br />
double hung flaking on<br />
w/wood muntins<br />
muntins,<br />
opening from<br />
top & bottom<br />
excellent<br />
good, some<br />
moss<br />
accumulation<br />
good, has<br />
been<br />
modified<br />
with an<br />
additional<br />
sling lock on<br />
bottom sash<br />
excellent no good west signs of past<br />
condensation<br />
accumulation on<br />
muntins<br />
139a<br />
139b<br />
double hung fair, flaking on good<br />
w/wood sill and outer<br />
muntins, casing<br />
opening from<br />
bottom<br />
double hung fair, extensive good<br />
w/wood flaking on sill<br />
muntins, and outer casing<br />
opening from<br />
bottom<br />
good moss<br />
accumulation<br />
good moss<br />
accumulation<br />
good, lock yes no good west yes<br />
and pulls are<br />
intact<br />
good, lock yes no good west yes<br />
and pulls are<br />
intact<br />
Straub Hall Window Condition Assessment - 9
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
140a<br />
141a<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
bottom<br />
Conditions<br />
Window<br />
Paint<br />
Parts*<br />
excellent excellent excellent fair, initial<br />
lock no<br />
longer<br />
functions,<br />
but is still in<br />
place, a new<br />
lock placed<br />
nest to old<br />
one<br />
double hung good excellent good, some<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
moss<br />
accumulation<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
fair, chipped<br />
but<br />
functional<br />
Facing<br />
Elev. Comments Photo<br />
yes no excellent north modified with various<br />
types of diffuse glass<br />
poor, right<br />
weight cord<br />
broken, top<br />
fixed in place<br />
with paint<br />
no fair west<br />
142a<br />
142b<br />
fixed wood<br />
window<br />
w/muntins<br />
over a<br />
double hung<br />
w/wood<br />
muntins<br />
which is<br />
operable<br />
from top &<br />
bottom<br />
fixed wood<br />
window<br />
w/muntins<br />
over a<br />
double hung<br />
w/wood<br />
muntins<br />
which is<br />
operable<br />
from top &<br />
bottom<br />
excellent excellent good, large<br />
amount of<br />
moss<br />
accumulation<br />
excellent excellent good, large<br />
amount of<br />
moss<br />
accumulation<br />
excellent<br />
excellent<br />
poor, top<br />
window<br />
stuck in<br />
place, lower<br />
window<br />
operable<br />
poor, top<br />
window<br />
stuck in<br />
place, lower<br />
window<br />
operable<br />
no excellent north opens into courtyard yes<br />
no excellent north opens into courtyard<br />
Straub Hall Window Condition Assessment - 10
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
142c<br />
transome<br />
window,<br />
fixed wood<br />
window with<br />
muntins<br />
Conditions<br />
Window<br />
Paint<br />
Parts*<br />
excellent excellent excellent, wood<br />
sill<br />
Brick Sill<br />
Facing<br />
Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
none no no excellent north opens into courtyard<br />
142d<br />
146a<br />
146a<br />
fixed wood<br />
window<br />
w/muntins<br />
over a<br />
double hung<br />
w/wood<br />
muntins<br />
which is<br />
operable<br />
from top &<br />
bottom<br />
gable end<br />
clearstories,<br />
w/wood<br />
muntins and<br />
mullions<br />
gable end<br />
clearstories,<br />
w/wood<br />
muntins and<br />
mullions<br />
excellent excellent good, large<br />
amount of<br />
moss<br />
accumulation<br />
excellent excellent unable to<br />
evaluate due to<br />
height<br />
excellent<br />
appears to<br />
be in<br />
excellent<br />
condition<br />
excellent excellent unable to appears to<br />
evaluate due to be in<br />
height excellent<br />
condition<br />
poor, top<br />
window<br />
stuck in<br />
place, lower<br />
window<br />
operable<br />
yes, the<br />
windows on<br />
either end<br />
appear to be<br />
operable,<br />
due to the<br />
presence of<br />
hardware<br />
yes, the<br />
windows on<br />
either end<br />
appear to be<br />
operable,<br />
due to the<br />
presence of<br />
hardware<br />
no excellent north opens into courtyard<br />
no excellent north Assessment was made<br />
from ground level,<br />
window height ~ 12'<br />
no excellent north Assessment was made<br />
from ground level,<br />
window height ~ 12'<br />
yes<br />
Straub Hall Window Condition Assessment - 11
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
L150a arched<br />
transoms,<br />
w/wood<br />
mullions &<br />
muntins<br />
Paint<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent good, heat lock and no no excellent east Does the lock and chain yes<br />
damage chain<br />
suggest that these<br />
attached in<br />
windows were operable<br />
Lobby<br />
before the connecting<br />
interior<br />
coridoor was installed<br />
L150b<br />
L150c<br />
L150d<br />
L150e<br />
L150f<br />
152Aa<br />
arched<br />
transoms,<br />
w/wood<br />
mullions &<br />
muntins<br />
arched<br />
transoms,<br />
w/wood<br />
mullions &<br />
muntins<br />
arched<br />
transoms,<br />
w/wood<br />
mullions &<br />
muntins<br />
arched<br />
transoms,<br />
w/wood<br />
mullions &<br />
muntins<br />
arched<br />
transoms,<br />
w/wood<br />
mullions &<br />
muntins<br />
excellent excellent good, heat<br />
damage<br />
excellent excellent good, heat<br />
damage<br />
no no excellent east interior yes<br />
no no excellent east interior yes<br />
excellent excellent excellent, wood none no no excellent west yes<br />
sill<br />
excellent excellent excellent, wood none no no excellent west<br />
sill<br />
excellent excellent excellent, wood none no no excellent west<br />
sill<br />
double hung excellent excellent excellent excellent yes no excellent west diffuse glazing<br />
w/wood<br />
muntins,<br />
opening from<br />
bottom<br />
Straub Hall Window Condition Assessment - 12
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
152Ba<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
Paint<br />
deeply flaked<br />
sill and lower<br />
exterior casing<br />
Window<br />
Parts*<br />
excellent<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
major moss excellent yes no fair south major moss<br />
yes<br />
accumulation<br />
accumulation, sill sits<br />
~1" above ground level<br />
153a<br />
154a<br />
double hung<br />
w/wood<br />
muntins<br />
excellent excellent major moss<br />
accumulation<br />
double hung excellent, some<br />
w/wood chipping on<br />
muntins and exterior<br />
a fixed upper<br />
excellent good, minor<br />
with exterior moss<br />
wood framed accumulation<br />
screen<br />
excellent no no excellent west this window has been<br />
sheetrocked over from<br />
the interior, it is located<br />
in the women's<br />
bathroom. Assessment<br />
made from exterior.<br />
excellent not no excellent south yes<br />
accessible<br />
155a<br />
155b<br />
double hung good, some<br />
w/wood chipping<br />
muntins and<br />
a fixed upper<br />
double hung good, some<br />
w/wood chipping<br />
muntins and<br />
a fixed upper<br />
excellent<br />
with exterior<br />
wood framed<br />
screen<br />
good excellent yes no excellent south yes<br />
excellent good excellent no no good south yes<br />
156Ba<br />
double hung good, some<br />
w/wood chipping<br />
muntins and<br />
a fixed upper<br />
excellent good excellent,<br />
weight cord<br />
painted<br />
no no good south yes<br />
156Da<br />
double hung<br />
w/wood<br />
muntins<br />
not accessible not accessible not accessible not<br />
accessible<br />
not<br />
accessible<br />
not<br />
accessibl<br />
e<br />
not<br />
accessible<br />
south<br />
Window blocked by a<br />
testing maching and is<br />
unreachable to assess<br />
Straub Hall Window Condition Assessment - 13
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
156Db double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent good right weight no no good east yes<br />
with exterior<br />
cord missing<br />
wood framed<br />
screen<br />
156Dc<br />
156Dd<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
not accessible not accessible not accessible not<br />
accessible<br />
excellent<br />
excellent excellent<br />
with exterior<br />
wood framed<br />
screen<br />
good, lock<br />
and pulls are<br />
intact<br />
not<br />
accessible<br />
not not<br />
accessibl accessible<br />
e<br />
east<br />
Window blocked by a<br />
testing maching and is<br />
unreachable to assess<br />
no no good east the top section of the<br />
window was loose so it<br />
was unsafe to attempt<br />
to open the window<br />
yes<br />
168Cb<br />
168Ca<br />
170a<br />
S170a<br />
172a<br />
vinyl,<br />
horizontal<br />
slider<br />
vinyl,<br />
horizontal<br />
slider<br />
casement<br />
window with<br />
wood<br />
muntins<br />
6 pane fixed good, some<br />
window with chipping<br />
wood<br />
muntins<br />
6 pane<br />
double hung<br />
w/wood<br />
muntins<br />
excellent excellent flashed with<br />
metal<br />
excellent excellent flashed with<br />
metal<br />
excellent good good, minor<br />
moss<br />
accumulation<br />
good, some<br />
chipping<br />
excellent yes no excellent west bars and screens on<br />
new vinyl windows,<br />
exterior plants<br />
obstructing opening<br />
excellent yes no excellent north bars and screens on<br />
new vinyl windows<br />
new locking<br />
hardware -<br />
two sliders<br />
on top and<br />
two on<br />
bottom<br />
yes no excellent west altered from original<br />
configuration<br />
good excellent none no no good east has this window been<br />
replaced There seems<br />
to be groving for<br />
movement but it is<br />
unoperable.<br />
good<br />
good, moss<br />
accumulation<br />
good, lock yes no excellent west yes<br />
and pulls are<br />
intact<br />
yes<br />
yes<br />
yes<br />
yes<br />
Straub Hall Window Condition Assessment - 14
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
178a double hung<br />
w/wood<br />
muntins<br />
Paint<br />
excellent<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent excellent yes no excellent east yes<br />
with exterior<br />
wood framed<br />
screen<br />
178b<br />
double hung<br />
w/wood<br />
muntins<br />
good good, lower 3 not accessible excellent no no good west yes<br />
panels have<br />
been replaced<br />
with textured<br />
glass<br />
178c<br />
double hung<br />
w/wood<br />
muntins<br />
good<br />
excellent<br />
with exterior<br />
wood framed<br />
screen<br />
excellent excellent no no good west the top section of the<br />
window was loose so it<br />
was unsafe to attempt<br />
to open the window<br />
yes<br />
178Aa<br />
180a<br />
180b<br />
180c<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good excellent not<br />
accessible<br />
not<br />
accessible<br />
excellent excellent excellent excellent not<br />
accessible<br />
excellent<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
excellent<br />
with vertical<br />
blinds<br />
attached to<br />
casement<br />
excellent<br />
with vertical<br />
blinds<br />
attached to<br />
casing<br />
no good east This window was only<br />
able to be accessed from<br />
exterior<br />
no excellent east<br />
excellent excellent yes no excellent west yes<br />
good, some<br />
moss<br />
accumulation<br />
right weight no no good west yes<br />
cord missing<br />
Straub Hall Window Condition Assessment - 15
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
186a hopper with<br />
wood<br />
muntins<br />
186b<br />
189a<br />
189b<br />
191a<br />
hopper with<br />
wood<br />
muntins<br />
double<br />
casement<br />
double<br />
casement<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
excellent<br />
good, some<br />
chipping<br />
interior muntins<br />
and sash<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
interior muntins<br />
and sash<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
top of casing<br />
removed for<br />
pipe<br />
good<br />
good, one<br />
glass pane<br />
has wires<br />
good<br />
excellent<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
not accessible N/A no not<br />
accessibl<br />
e<br />
good, some<br />
moss<br />
accumulation<br />
good, minor<br />
moss<br />
accumulation<br />
good, minor<br />
moss<br />
accumulation<br />
good moss<br />
accumulation<br />
Facing<br />
Elev. Comments Photo<br />
yes<br />
fair west this window leads to a<br />
concerte cove below<br />
grade and does not let<br />
in air or much light at<br />
all<br />
excellent yes no excellent south yes<br />
excellent no no good south yes<br />
excellent no no good south yes<br />
missing<br />
pulls<br />
yes no good north yes<br />
Straub Hall Window Condition Assessment - 16
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
193a<br />
194a<br />
195a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
excellent, some<br />
chipping on<br />
exterior<br />
good<br />
Window<br />
Parts*<br />
good, wood<br />
framed<br />
screen<br />
attached<br />
outside<br />
excellent<br />
with<br />
horizontal<br />
blinds<br />
attached to<br />
casing<br />
good, bottom<br />
6 panels are<br />
wood, top 6<br />
panels are<br />
painted glass<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent missing yes no excellent north<br />
pulls<br />
good, some<br />
moss<br />
accumulation<br />
not accessible<br />
missing<br />
pulls<br />
good, lock yes, top falls<br />
and pulls are down if<br />
intact unlocked<br />
yes no good south yes<br />
no good north yes<br />
196a<br />
double hung<br />
w/wood<br />
muntins<br />
excellent<br />
excellent<br />
with exterior<br />
wood framed<br />
screen<br />
excellent excellent yes no excellent north yes<br />
196Aa<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
excellent good, minor<br />
with exterior moss<br />
wood framed accumulation<br />
screen<br />
missing<br />
pulls<br />
no, painted<br />
into place<br />
no excellent north This window does not<br />
appear on plans<br />
yes<br />
S198a<br />
fixed wood<br />
window with<br />
muntins<br />
excellent excellent good N/A no, not an<br />
operable<br />
window<br />
no excellent north yes<br />
Straub Hall Window Condition Assessment - 17
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
199a<br />
199b<br />
199Aa<br />
199Ab<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Conditions<br />
Window<br />
Paint<br />
Parts*<br />
good, some good, a few<br />
chipping on glass panels<br />
interior, are cracked<br />
extensive or broken<br />
chipping on<br />
exterior<br />
fair, extensive good good, minor<br />
flaking on<br />
moss<br />
muntins<br />
accumulation<br />
excellent excellent excellent excellent yes, but the<br />
top drops<br />
when<br />
unlocked<br />
excellent excellent good, minor<br />
moss<br />
accumulation<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
excellent missing no, top falls<br />
upper left down if<br />
cord unlocked<br />
Facing<br />
Elev. Comments Photo<br />
no good south the wood casing around yess<br />
this window is stained<br />
to match wainscot<br />
excellent yes no excellent east yes<br />
no excellent east the wood casing around<br />
this window is stained<br />
to match wainscot<br />
excellent yes no excellent north the wood casing around<br />
this window is stained<br />
to match wainscot<br />
yes<br />
yes<br />
201a<br />
201b<br />
202a<br />
202b<br />
H202a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
excellent<br />
good, some<br />
moss<br />
accumulation<br />
excellent excellent good, large<br />
amount of<br />
moss<br />
accumulation<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
stacked interior good,<br />
wood exterior poor<br />
awning<br />
window with<br />
muntins<br />
good, some<br />
splitting in<br />
the lower<br />
casing<br />
good<br />
good<br />
excellent yes no good east yes<br />
excellent<br />
not<br />
accessible<br />
no excellent north yes<br />
excellent excellent yes no good east yes<br />
good, metal<br />
sheathing<br />
covering sill<br />
good, metal<br />
sheathing<br />
covering sill<br />
excellent<br />
yes, a bit<br />
sticky<br />
missing lock yes, opens to<br />
rooftop<br />
no good east This window does not<br />
appear on plans<br />
yes<br />
no good south yes<br />
Straub Hall Window Condition Assessment - 18
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
203a double hung<br />
w/wood<br />
muntins<br />
204a<br />
stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
Conditions<br />
Paint<br />
excellent<br />
poor, sill w/out<br />
paint, deep<br />
flaking on<br />
exterior casing,<br />
interior muntins<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
Window<br />
Parts*<br />
excellent<br />
with scars<br />
from locks<br />
stool cracked sill flashed<br />
metal, good<br />
condition<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, large excellent, yes, a bit no good north yes<br />
amount of right weight sticky<br />
moss cord is<br />
accumulation freying<br />
excellent yes yes fair south interior muntins<br />
showing signs of past<br />
condensation<br />
accumulation<br />
yes<br />
204b<br />
stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
poor, sill<br />
out/out paint,<br />
deep flaking on<br />
exterior casing,<br />
interior muntins<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
lower jamb<br />
on upper<br />
window with<br />
multiple<br />
cracks at<br />
hardware<br />
attachment<br />
sill flashed<br />
metal, good<br />
condition<br />
excellent yes yes fair south interior muntins<br />
showing signs of past<br />
condensation<br />
accumulation<br />
yes<br />
205a<br />
207a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
excellent excellent good moss<br />
accumulation<br />
excellent<br />
excellent<br />
with<br />
horizontal<br />
blinds<br />
attached to<br />
casing<br />
good moss<br />
accumulation<br />
excellent yes no excellent north yes<br />
excellent<br />
not<br />
accessible<br />
no excellent north yes<br />
Straub Hall Window Condition Assessment - 19
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
208a<br />
209a<br />
210a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
excellent, some<br />
chipping on<br />
interior<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
Window<br />
Parts*<br />
stool<br />
damaged,<br />
lower 8 glass<br />
panes<br />
painted white<br />
good, few<br />
chips and<br />
dents<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
good, metal good, lock<br />
sheathing and pulls are<br />
covering sill intact<br />
good moss<br />
accumulation<br />
top window<br />
sits on<br />
exterior<br />
supports for<br />
ventilation,<br />
bottom is<br />
fixed<br />
Facing<br />
Elev. Comments Photo<br />
no fair south sill damage is from stall yes<br />
sizes changing through<br />
the years and the slot<br />
for stall supports<br />
moving<br />
excellent yes no good north yes<br />
excellent excellent yes no excellent south opens to rooftop yes<br />
210b<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
dropped good, mortar<br />
ceiling crack evident<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent yes no excellent south opens to rooftop yes<br />
210c<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent excellent not<br />
accessible<br />
no excellent south opens to rooftop<br />
Straub Hall Window Condition Assessment - 20
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
210d<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
dropped excellent double lock, yes no excellent south<br />
ceiling<br />
no pull<br />
attached to<br />
above<br />
upper casing,<br />
awning<br />
vertical<br />
blinds<br />
attached<br />
S210a<br />
211a<br />
212a<br />
H219a<br />
220a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
16 pane,<br />
double hung<br />
w/ wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, few<br />
chips and<br />
dents<br />
excellent excellent good, moss<br />
accumulation<br />
excellent<br />
excellent<br />
excellent<br />
with scars<br />
from locks<br />
excellent excellent no, painted<br />
into place<br />
good, large<br />
amount of<br />
moss<br />
accumulation<br />
excellent, good, some<br />
minor flaking moss<br />
on sill accumulation<br />
excellent excellent good moss<br />
accumulation<br />
lock is<br />
broken but<br />
functional<br />
excellent<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
no excellent south yes<br />
no excellent north yes<br />
no excellent north yes<br />
excellent yes no excellent east yes<br />
excellent fair, sticky no excellent north<br />
Straub Hall Window Condition Assessment - 21
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
221a<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
Conditions<br />
Window<br />
Paint<br />
Parts*<br />
excellent excellent good, moss<br />
accumulation<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent poor, very no excellent north<br />
sticky<br />
221b<br />
double hung fair, extensive<br />
w/wood flaking on sill<br />
muntins,<br />
opening from<br />
top & bottom<br />
excellent<br />
good, minor<br />
moss<br />
accumulation<br />
excellent excellent no excellent west<br />
223a<br />
double hung fair, extensive<br />
w/wood flaking on sill<br />
muntins,<br />
opening from<br />
top & bottom<br />
left jamb<br />
cracked, sill<br />
checked,<br />
good, minor<br />
moss<br />
accumulation<br />
upper left<br />
weight cord<br />
broken<br />
poor no fair east window not on current<br />
plan<br />
224a<br />
double hung fair, extensive<br />
w/wood flaking on sill<br />
muntins,<br />
opening from<br />
top & bottom<br />
excellent excellent excellent yes no excellent east<br />
225a<br />
double hung fair, extensive<br />
w/wood flaking on sill<br />
muntins,<br />
opening from<br />
top & bottom<br />
excellent<br />
good, some<br />
moss<br />
accumulation<br />
excellent<br />
yes, a bit<br />
sticky<br />
no excellent west<br />
226a<br />
stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
excellent excellent excellent yes no excellent east two large nails in sill yes<br />
Straub Hall Window Condition Assessment - 22
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
226b stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
227a double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
Conditions<br />
Window Brick Sill<br />
Facing<br />
Paint<br />
Parts* Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
excellent excellent excellent excellent yes no excellent east<br />
fair, extensive<br />
flaking on sill<br />
and outer casing<br />
upper jamb<br />
damaged<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no good west signs of past<br />
condensation<br />
accumulation on<br />
muntins<br />
228a<br />
228b<br />
229a<br />
stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
sill flaking excellent excellent excellent yes no excellent east opens onto fire escape<br />
stacked sill flaking excellent excellent excellent yes no excellent east<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
double hung fair, extensive stool cracked good, minor excellent yes no excellent west<br />
w/wood flaking on sill and repaired moss<br />
muntins, and outer casing<br />
accumulation<br />
opening from<br />
top & bottom<br />
230a<br />
stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
sill flaking excellent excellent excellent yes no excellent east opens onto fire escape<br />
Straub Hall Window Condition Assessment - 23
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
S230a<br />
231a<br />
16 pane,<br />
double hung<br />
w/ wood<br />
muntins<br />
Conditions<br />
Paint<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
sill flaking good excellent missing yes, a bit no good east yes<br />
upper left sticky<br />
cord<br />
double hung fair, extensive sill damaged good, some<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
flaking on sill<br />
and outer casing<br />
moss<br />
accumulation<br />
upper left<br />
cord broken<br />
yes no excellent west minor damage to upper<br />
sill on top window<br />
232a<br />
232b<br />
233a<br />
stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
sill flaking,<br />
minor flack on<br />
lower interior<br />
muntins due to<br />
past water<br />
accumulation<br />
sill flaking,<br />
minor flack on<br />
lower interior<br />
muntins due to<br />
past water<br />
accumulation<br />
no paint on sill,<br />
flaking on<br />
exterior casing<br />
excellent excellent excellent yes no excellent east<br />
excellent excellent excellent,<br />
top lock has<br />
been<br />
replaced<br />
excellent<br />
good, some<br />
moss<br />
accumulation<br />
yes no excellent east opens onto fire escape yes<br />
excellent yes no good west<br />
235a<br />
double hung flaking on sill<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
sash<br />
damaged<br />
good, some<br />
moss<br />
accumulation<br />
excellent yes no fair west top sash of top window<br />
deeply cracked<br />
Straub Hall Window Condition Assessment - 24
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
Window Brick Sill<br />
Facing<br />
# T y p e Paint<br />
Parts* Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
H236a N/A N/A N/A N/A N/A N/A N/A N/A east this is not a window but yes<br />
rather the elevator<br />
shaft. If a window once<br />
existed, all trace is gone<br />
237a<br />
double hung paint gone from<br />
w/wood sill<br />
muntins,<br />
opening from<br />
top & bottom<br />
jamb cracked,<br />
casing<br />
cracked<br />
good, some<br />
moss<br />
accumulation<br />
excellent yes no fair west casing and jamb on left<br />
side are cracked.<br />
238a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
excellent excellent excellent excellent,<br />
with cord<br />
protectors<br />
yes no excellent east yes<br />
239a<br />
double hung fair, flaking on<br />
w/wood sill and outer<br />
muntins, casing<br />
opening from<br />
top & bottom<br />
sash and<br />
muntins<br />
damaged by<br />
hardware<br />
rubbing<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no fair west sill used for planters yes<br />
240a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
flaking on sill excellent excellent Lots of<br />
leftover<br />
hardware<br />
remains on<br />
window, not<br />
currently<br />
serving any<br />
function<br />
yes no good east altered from original<br />
configuration<br />
yes<br />
Straub Hall Window Condition Assessment - 25
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
240b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Conditions<br />
Paint<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
flaking on sill excellent excellent excellent yes no good east cracked bottom sash on yes<br />
top window, upper sash<br />
on bottom window<br />
(appears to be result of<br />
hardware retrofit).<br />
241a<br />
double hung sill and bottom<br />
w/wood exterior casing<br />
muntins, flaking<br />
opening from<br />
top & bottom<br />
excellent<br />
good, some<br />
moss<br />
accumulation<br />
weight cord<br />
on lower<br />
right<br />
window<br />
broken<br />
OK, top<br />
window<br />
sticky<br />
no excellent west<br />
242a<br />
242b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
excellent excellent good, some<br />
moss<br />
accumulation<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
excellent excellent good, some<br />
moss<br />
accumulation<br />
excellent yes no excellent east yes<br />
excellent yes no excellent east<br />
243a<br />
double hung fair, extensive excellent good upper left<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
flaking on sill<br />
and outer casing<br />
cord broken<br />
OK no good north yes<br />
245a<br />
double hung fair<br />
w/wood<br />
muntins,<br />
opening from<br />
top & bottom<br />
excellent, good<br />
minor flaking<br />
on sill<br />
upper left<br />
cord broken<br />
OK no good north<br />
Straub Hall Window Condition Assessment - 26
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window<br />
#<br />
H245a<br />
Window<br />
T y p e<br />
**see L150a**<br />
Paint<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
H245b<br />
**see L150b**<br />
H245c<br />
**see L150c**<br />
251a<br />
double hung<br />
w/wood<br />
muntins<br />
fair, extensive good excellent right weight<br />
flaking on sill<br />
cord broken<br />
and outer casing<br />
no no good south yes<br />
252a<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
good,<br />
dropped<br />
ceiling<br />
attached at<br />
top<br />
excellent excellent yes no excellent east opens to rooftop yes<br />
253a<br />
254a<br />
double hung<br />
w/wood<br />
muntins<br />
12 pane<br />
double hung,<br />
with wood<br />
muntins<br />
good, some<br />
chipping<br />
good, vertical<br />
blinds<br />
attached at<br />
top<br />
excellent good, lower 6<br />
panels have<br />
been replaced<br />
with white<br />
painted<br />
wood<br />
good, some<br />
moss<br />
accumulation<br />
left weight<br />
cord broken<br />
no, top falls<br />
down if<br />
unlocked,<br />
bottom<br />
painted into<br />
place<br />
excellent excellent bottom is<br />
non-operable<br />
but top sinks<br />
2" resting on<br />
unseen<br />
exterior<br />
supports<br />
no good west yes<br />
no good east lower panels wood for<br />
privacy - this space is a<br />
restroom<br />
yes<br />
255a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
excellent<br />
good, some<br />
moss<br />
accumulation<br />
excellent<br />
not<br />
accessible<br />
no good west yes<br />
Straub Hall Window Condition Assessment - 27
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
256a<br />
257a<br />
258a<br />
258b<br />
259a<br />
270a<br />
270b<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
Window Brick Sill<br />
Facing<br />
Parts* Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
excellent good excellent yes no good east<br />
good, simple good, minor<br />
case to match moss<br />
wainscot accumulation<br />
excellent<br />
good, minor<br />
moss<br />
accumulation<br />
right case cut good, minor<br />
moss<br />
accumulation<br />
good,<br />
cracked stool<br />
good, moss<br />
accumulation<br />
excellent yes no excellent west yes<br />
right weight yes, but the<br />
cord missing top drops<br />
when<br />
unlocked<br />
excellent no, painted<br />
into place<br />
no good east yes<br />
no good east This window does not<br />
appear on plans<br />
excellent yes no good west yes<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached,<br />
excellent excellent yes no good<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent excellent yes no good<br />
east<br />
east<br />
split in bottom rail<br />
yes<br />
yes<br />
yes<br />
Straub Hall Window Condition Assessment - 28
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
S270a<br />
271a<br />
272a<br />
16 pane,<br />
double hung<br />
w/ wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
excellent excellent missing lock yes, very no good<br />
sticky<br />
splitting in<br />
case<br />
good, minor<br />
moss<br />
accumulation<br />
dropped good, minor<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent<br />
double lock,<br />
no pull<br />
above<br />
awning<br />
no, top falls<br />
down if<br />
unlocked<br />
Facing<br />
Elev. Comments Photo<br />
yes<br />
east<br />
no good west yes<br />
yes no good east<br />
272b<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
dropped good, minor<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
double lock,<br />
no pull<br />
above<br />
awning<br />
yes no good east<br />
273a<br />
274a<br />
double hung<br />
w/wood<br />
muntins<br />
12 pane<br />
double hung,<br />
with wood<br />
muntins<br />
good, some<br />
chipping<br />
excellent<br />
righ case in<br />
wall…<br />
all glass<br />
replaced with<br />
white painted<br />
wood<br />
good moss<br />
accumulation<br />
excellent<br />
yes, a bit<br />
sticky<br />
no good west yes<br />
excellent excellent yes no good east wood replacing glass<br />
for privacy - another<br />
restroom<br />
yes<br />
278a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, chips<br />
and dents<br />
excellent excellent not<br />
accessible<br />
no good east<br />
Straub Hall Window Condition Assessment - 29
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
Window<br />
# T y p e Paint<br />
Parts*<br />
278b double hung good, some good,<br />
w/wood chipping horizontal<br />
muntins<br />
blinds<br />
attached at<br />
top, chips<br />
and dents<br />
279a double hung good, some good, good moss excellent<br />
w/wood chipping horizontal accumulation<br />
muntins<br />
blinds<br />
attached at<br />
top<br />
279b double hung good, some good, good moss<br />
w/wood chipping horizontal accumulation<br />
muntins<br />
blinds<br />
attached at<br />
top, chips<br />
and dents<br />
283a not accessible not accessible not accessible not accessible not<br />
accessible<br />
283b not accessible not accessible not accessible not accessible not<br />
accessible<br />
284a<br />
284b<br />
S284a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
16 pane,<br />
double hung<br />
w/ wood<br />
muntins<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent not no good east<br />
accessible<br />
good, some<br />
moss<br />
accumulation<br />
good moss<br />
accumulation<br />
excellent excellent good, some<br />
moss<br />
accumulation<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
no good west yes<br />
excellent yes no good west yes<br />
broken right<br />
weight cord<br />
excellent<br />
excellent<br />
not<br />
accessible<br />
not<br />
accessible<br />
no, painted<br />
into place<br />
no, painted<br />
into place<br />
no, painted<br />
into place<br />
not<br />
accessibl<br />
e<br />
not<br />
accessibl<br />
e<br />
N/A west this room is under lock<br />
and key due to<br />
confidential files<br />
N/A west this room is under lock<br />
and key due to<br />
confidential files<br />
no good south yes<br />
no good south yes<br />
no good east yes<br />
Straub Hall Window Condition Assessment - 30
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
H286a stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
H286b stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
H286c stacked<br />
wood<br />
awning<br />
windows<br />
with wood<br />
muntins<br />
287a double hung<br />
w/wood<br />
muntins<br />
288a<br />
289a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Conditions<br />
Paint<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent good, some excellent bottom is no good north yes<br />
moss<br />
operable, top<br />
accumulation<br />
is not<br />
excellent excellent good, moss<br />
accumulation<br />
good, some<br />
chipping<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
excellent<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, split in<br />
casing<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
excellent<br />
good, some<br />
moss<br />
accumulation<br />
good, minor<br />
moss<br />
accumulation<br />
good<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no excellent north yes<br />
missing<br />
pulls<br />
excellent<br />
left weight<br />
cord broken<br />
missing<br />
upper left<br />
cord<br />
yes no good north yes<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
no good south<br />
yes, top sinks no good south<br />
no, painted<br />
into place<br />
no good north<br />
Straub Hall Window Condition Assessment - 31
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
290a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Conditions<br />
Window<br />
Paint<br />
Parts*<br />
excellent excellent good, minor<br />
moss<br />
accumulation<br />
Brick Sill<br />
Facing<br />
Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
excellent yes no good north<br />
290b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
excellent excellent good, minor<br />
moss<br />
accumulation<br />
excellent yes no good north<br />
S290a<br />
291a<br />
16 pane, good, some<br />
double hung chipping<br />
w/ wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
excellent<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good, some<br />
moss<br />
accumulation<br />
good, minor<br />
moss<br />
accumulation<br />
broken cord<br />
on left<br />
no no good north yes<br />
excellent yes no excellent south yes<br />
Straub Hall Window Condition Assessment - 32
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
292a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Conditions<br />
Window<br />
Paint<br />
Parts*<br />
excellent excellent good moss<br />
accumulation<br />
Brick Sill<br />
Facing<br />
Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
excellent yes no excellent north<br />
292b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
excellent excellent good moss<br />
accumulation<br />
excellent yes no excellent north<br />
293a<br />
294a<br />
295a<br />
295b<br />
295c<br />
double hung<br />
w/wood<br />
muntins<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
excellent<br />
good, minor<br />
moss<br />
accumulation<br />
excellent<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
no excellent south yes<br />
excellent good, lower 8 not accessible excellent no no good north<br />
panels have<br />
been painted<br />
white<br />
double hung w/wood muntins<br />
double hung excellent excellent good, minor excellent yes no excellent south yes<br />
w/wood interior, severe<br />
moss<br />
muntins chipping on<br />
accumulation<br />
exterior<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
good, some<br />
chipping<br />
excellent,<br />
horizontal<br />
and vinyl<br />
blinds<br />
attached<br />
excellent,<br />
horizontal<br />
and vinyl<br />
blinds<br />
attached<br />
good, minor<br />
moss<br />
accumulation<br />
good moss<br />
accumulation<br />
excellent yes no excellent south yes<br />
excellent<br />
no, painted<br />
into place<br />
no excellent east yes<br />
Straub Hall Window Condition Assessment - 33
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
298a<br />
298b<br />
301a<br />
301b<br />
302a<br />
302b<br />
H302a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Conditions<br />
Paint<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
excellent<br />
excellent excellent good, some<br />
moss<br />
accumulation<br />
good, some<br />
chipping<br />
excellent<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
good, some<br />
chipping<br />
stacked interior is good<br />
wood with minimal<br />
awning chipping,<br />
window with exterior is very<br />
muntins poor with<br />
extensive<br />
chipping<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good moss excellent not no good east<br />
accumulation<br />
accessible<br />
good, some<br />
moss<br />
accumulation<br />
good, some<br />
moss<br />
accumulation<br />
excellent<br />
excellent<br />
not<br />
accessible<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
no excellent north<br />
no good east<br />
excellent yes no good north<br />
excellent excellent yes, but the<br />
top drops<br />
when<br />
unlocked<br />
good, some<br />
moss<br />
accumulation<br />
excellent<br />
no, painted<br />
into place<br />
no good south yes<br />
no good east<br />
excellent excellent excellent yes no excellent south yes<br />
Straub Hall Window Condition Assessment - 34
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
H302b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Conditions<br />
Window<br />
Paint<br />
Parts*<br />
excellent excellent excellent excellent, all<br />
new<br />
hardware<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
yes no excellent south this window to seems to yes<br />
be new construction. It<br />
has new hardware and<br />
does not appear as a<br />
window with casement<br />
on the current plans<br />
303a<br />
304a<br />
304b<br />
double hung<br />
w/wood<br />
muntins<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
excellent<br />
poor, sill w/out<br />
paint, deep<br />
flaking on<br />
exterior casing,<br />
interior muntins<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
poor, sill w/out<br />
paint, deep<br />
flaking on<br />
exterior casing,<br />
interior muntins<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
minor<br />
cracking or<br />
splitting in<br />
casing<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no good north yes<br />
excellent excellent yes no good south most 'damage' to this<br />
window is superficial<br />
and can be repaired<br />
excellent excellent yes no good south most 'damage' to this<br />
window is superficial<br />
and can be repaired<br />
yes<br />
305a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, vertical<br />
blinds<br />
attached at<br />
top<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no excellent north yes<br />
Straub Hall Window Condition Assessment - 35
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
307a double hung<br />
w/wood<br />
muntins<br />
308a<br />
309a<br />
310a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Conditions<br />
Paint<br />
excellent<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good, lower 8<br />
panels have<br />
been painted<br />
white<br />
excellent<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, some excellent yes, a bit no excellent north<br />
moss<br />
sticky<br />
accumulation<br />
good, some<br />
deterioration of<br />
mortar joints<br />
good, some<br />
moss<br />
accumulation<br />
new lock on<br />
right,<br />
missing left<br />
weight cord<br />
excellent<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
not accessible not accessible not accessible not<br />
accessible<br />
yes no good south yes<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
not<br />
accessible<br />
no good north yes<br />
not<br />
accessibl<br />
e<br />
N/A south blocked by bookcases<br />
and furniture<br />
310b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
poor, sill w/out<br />
paint, deep<br />
flaking on<br />
exterior casing,<br />
interior muntins<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent excellent yes no good south yes<br />
Straub Hall Window Condition Assessment - 36
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
310c<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Conditions<br />
Paint<br />
poor, sill w/out<br />
paint, deep<br />
flaking on<br />
exterior casing,<br />
interior muntins<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
Window<br />
Parts*<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
Brick Sill<br />
Facing<br />
Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
excellent excellent yes no good south yes<br />
310d<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
poor, sill w/out<br />
paint, deep<br />
flaking on<br />
exterior casing,<br />
interior muntins<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent excellent yes no good south yes<br />
S310a<br />
311a<br />
312a<br />
double hung,<br />
rounded<br />
arch, 32 pane<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
interior is good<br />
with minimal<br />
chipping,<br />
exterior is very<br />
poor with<br />
extensive<br />
chipping<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
good, lower<br />
portion may<br />
be newer<br />
construction<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
excellent<br />
good moss<br />
accumulation<br />
good moss<br />
accumulation<br />
missing<br />
pulls<br />
no no good south This is a double height<br />
window and is also<br />
qualified as S410a<br />
excellent yes no good north<br />
excellent yes no good north<br />
yes<br />
Straub Hall Window Condition Assessment - 37
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
H319a<br />
320a<br />
321a<br />
321b<br />
323a<br />
324a<br />
double hung<br />
16 pane<br />
w/wood<br />
muntins,<br />
opening from<br />
bottom<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
interior is good<br />
with minimal<br />
chipping,<br />
exterior is very<br />
poor with<br />
extensive<br />
chipping<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
excellent<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent excellent no, top falls no good east yes<br />
down if<br />
unlocked<br />
split in case,<br />
horizontal<br />
blinds<br />
attached<br />
excellent<br />
with vertical<br />
blinds<br />
attached to<br />
casement<br />
excellent<br />
with vertical<br />
blinds<br />
attached to<br />
casement<br />
excellent<br />
with vertical<br />
blinds<br />
attached to<br />
casement<br />
good, vertical<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
case<br />
good, moss<br />
accumulation<br />
good, minor<br />
moss<br />
accumulation<br />
good, some<br />
moss<br />
accumulation<br />
good, minor<br />
moss<br />
accumulation<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no excellent north yes<br />
excellent yes no excellent north<br />
excellent<br />
not<br />
accessible<br />
no excellent west<br />
excellent yes no excellent west yes<br />
broken cord<br />
on left<br />
top sinks,<br />
bottom no<br />
(painted)<br />
no good east yes<br />
Straub Hall Window Condition Assessment - 38
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
325a<br />
326a<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
Window<br />
Parts*<br />
split in case,<br />
horizontal<br />
blinds<br />
attached<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, minor missing yes no good west yes<br />
moss pulls<br />
accumulation<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent excellent yes no good east yes<br />
326b<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
dropped good, minor<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent yes no good east<br />
327a<br />
328a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
stacked excellent<br />
wood interior, severe<br />
awning chipping on<br />
window with exterior<br />
muntins<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good, minor<br />
moss<br />
accumulation<br />
dropped good, minor<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent yes no excellent west<br />
excellent yes no excellent east<br />
Straub Hall Window Condition Assessment - 39
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
328b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
excellent<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
dropped excellent excellent yes no excellent east yes<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
329a<br />
S330a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
double hung, good, some<br />
rounded chipping<br />
arch, 32 pane<br />
w/wood<br />
muntins<br />
excellent,<br />
horizontal<br />
and vinyl<br />
blinds<br />
attached<br />
excellent excellent yes, but the<br />
top drops<br />
when<br />
unlocked<br />
excellent excellent broken cord<br />
on left<br />
no excellent west<br />
no no good east This is a double height<br />
window and is also<br />
qualified as S430a<br />
yes<br />
331a<br />
H331a<br />
double hung<br />
w/wood<br />
muntins<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
excellent excellent yes, but the<br />
top drops<br />
when<br />
unlocked<br />
excellent excellent excellent pull on<br />
upper<br />
awning was<br />
replaced<br />
with another<br />
lock<br />
no, locked<br />
into place<br />
no good west<br />
no fair east yes<br />
Straub Hall Window Condition Assessment - 40
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
332a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
dropped excellent excellent yes no good east yes<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
332b<br />
stacked excellent<br />
wood interior, severe<br />
awning chipping on<br />
window with exterior<br />
muntins<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent excellent yes no good east<br />
333a<br />
335a<br />
H336a<br />
337a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
excellent<br />
interior, severe<br />
chipping on<br />
exterior<br />
good, some<br />
chipping<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, split in<br />
jamb<br />
good, some<br />
moss<br />
accumulation<br />
good, some<br />
moss<br />
accumulation<br />
double hung excellent excellent good, some<br />
16 pane<br />
w/wood<br />
muntins,<br />
opening from<br />
bottom<br />
moss<br />
accumulation<br />
double hung<br />
w/wood<br />
muntins<br />
excellent<br />
interior, some<br />
chipping on<br />
exterior<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
good, minor<br />
moss<br />
accumulation<br />
broken cord<br />
on right, no<br />
pulls<br />
missing left<br />
pull<br />
excellent,<br />
with cord<br />
protectors<br />
excellent<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
no good east yes<br />
yes no good west yes<br />
no, top falls<br />
down if<br />
unlocked,<br />
bottom<br />
painted into<br />
place<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
no fair east yes<br />
no excellent west<br />
Straub Hall Window Condition Assessment - 41
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
337b<br />
338a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
12 pane w/<br />
wood<br />
muntins<br />
Paint<br />
excellent<br />
interior, some<br />
chipping on<br />
exterior<br />
excellent<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, good, minor missing yes, but the no good west yes<br />
horizontal moss upper left top drops<br />
blinds accumulation cord when<br />
attached at<br />
unlocked<br />
top, crack in<br />
stool<br />
all<br />
good excellent, no, painted no good east yes<br />
transparent<br />
with cord into place<br />
glass<br />
protectors<br />
replaced with<br />
textured or<br />
frosted glass<br />
339a<br />
H340a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
stacked interior is<br />
wood exxcellent,<br />
awning exterior is good<br />
window with with some<br />
muntins chipping<br />
good, some good, some<br />
chips and moss<br />
cracks in case accumulation<br />
excellent<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
no good west yes<br />
excellent excellent excellent yes no excellent east yes<br />
341a<br />
342a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
stacked good, some<br />
wood chipping on<br />
awning interior,<br />
window with extensive<br />
muntins chipping on<br />
exterior<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no good west<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent excellent yes no excellent east yes<br />
Straub Hall Window Condition Assessment - 42
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
342b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
dropped excellent excellent yes no excellent east<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
343a<br />
344a<br />
344b<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, split in<br />
case<br />
excellent excellent yes no good west<br />
dropped excellent excellent yes no excellent east<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
vertical<br />
blinds<br />
attached,<br />
cracks on<br />
exterior of<br />
innner sash<br />
excellent excellent yes no good east yes<br />
Straub Hall Window Condition Assessment - 43
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
345a<br />
346a<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
Window<br />
Parts*<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, minor excellent yes, top sinks no good west<br />
moss<br />
accumulation<br />
dropped good, minor<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
vertical<br />
blinds<br />
attached,<br />
added strip<br />
on stool<br />
excellent yes no good east yes<br />
346b<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
dropped good, minor<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
vertical<br />
blinds<br />
attached<br />
excellent yes no good east<br />
347a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, vertical<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
case<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no good west yes<br />
348a<br />
stacked good, some<br />
wood chipping on<br />
awning interior,<br />
window with extensive<br />
muntins chipping on<br />
exterior<br />
some<br />
cracking in<br />
the sash<br />
excellent excellent yes no good east<br />
Straub Hall Window Condition Assessment - 44
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
348b<br />
349a<br />
350a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping<br />
stacked excellent<br />
wood interior, some<br />
awning chipping on<br />
window with exterior<br />
muntins<br />
Window<br />
Parts*<br />
some<br />
cracking in<br />
the sash<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached and<br />
some<br />
cracking in<br />
stool<br />
Brick Sill<br />
Facing<br />
Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
excellent excellent yes no good east yes<br />
good, minor<br />
moss<br />
accumulation,<br />
with a chip on<br />
one brick edge<br />
missing left<br />
weight cord<br />
no no good west yes<br />
good excellent yes no good east yes<br />
350b<br />
stacked excellent<br />
wood interior, some<br />
awning chipping on<br />
window with exterior<br />
muntins<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
good excellent yes no good east<br />
351a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, vertical<br />
blinds<br />
attached at<br />
top<br />
good, minor<br />
moss<br />
accumulation<br />
missing lock yes no good west yes<br />
Straub Hall Window Condition Assessment - 45
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
352a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
dropped excellent excellent yes no good east yes<br />
ceiling<br />
attached to<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached,<br />
sash pulling<br />
away from<br />
itself<br />
352b<br />
353a<br />
354a<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
Picture good, some<br />
window with chipping<br />
awning, 12<br />
panes and<br />
wood<br />
muntins<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached,<br />
sash pulling<br />
away from<br />
itself<br />
excellent excellent yes no excellent east<br />
excellent good, minor<br />
moss<br />
accumulation<br />
excellent yes no excellent west<br />
good excellent double lock, yes no good east yes<br />
no pull<br />
above<br />
awning<br />
Straub Hall Window Condition Assessment - 46
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
355a<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
excellent<br />
interior, some<br />
chipping on<br />
exterior<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, vertical good, some excellent yes no good west yes<br />
blinds moss<br />
attached at accumulation<br />
top, small<br />
crack in<br />
casing<br />
356a<br />
double hung<br />
w/wood<br />
muntins<br />
poor, sill w/out splitting in<br />
paint, deep case and<br />
flaking on sash, with<br />
exterior casing, horizontal<br />
interior muntins blinds<br />
showing signs attached at<br />
of past top of case<br />
condensation<br />
accumulation<br />
excellent excellent yes no good east yes<br />
357a<br />
358a<br />
359a<br />
370a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
excellent<br />
interior, some<br />
chipping on<br />
exterior<br />
good, some<br />
chipping<br />
stacked excellent<br />
wood interior, some<br />
awning chipping on<br />
window with exterior<br />
muntins<br />
excellent<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing<br />
good, some<br />
moss<br />
accumulation<br />
good, some<br />
chipping on<br />
corners of<br />
bricks<br />
good, some<br />
moss<br />
accumulation<br />
missing lock yes no excellent west<br />
excellent yes no excellent east yes<br />
excellent yes no excellent west<br />
excellent excellent yes no excellent east<br />
Straub Hall Window Condition Assessment - 47
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
370b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
excellent<br />
interior, some<br />
chipping on<br />
exterior<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
dropped excellent new lock on yes no excellent east yes<br />
ceiling<br />
lower right<br />
attached to<br />
upper casing<br />
S370a<br />
371a<br />
H372a<br />
373a<br />
double hung,<br />
rounded<br />
arch, 32 pane<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Picture<br />
window with<br />
awning, 12<br />
panes and<br />
wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
interior is good<br />
with minimal<br />
chipping,<br />
exterior is very<br />
poor with<br />
extensive<br />
chipping<br />
good, some<br />
chipping<br />
good excellent good yes no good east This is a double height<br />
window and is also<br />
qualified as S470a<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good, some<br />
moss<br />
accumulation<br />
excellent good good, some<br />
moss<br />
accumulation<br />
good, some<br />
chipping<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good, some<br />
moss<br />
accumulation<br />
right weight<br />
cord broken<br />
intact nonpainted<br />
lock<br />
and pull<br />
with an<br />
additional<br />
locking<br />
mechanism<br />
excellent<br />
no no good west<br />
yes no good east the new lock is because<br />
the old lock's groove no<br />
longer holds the<br />
original lock in place<br />
yes, but the<br />
top drops<br />
when<br />
unlocked<br />
no good west<br />
yes<br />
yes<br />
Straub Hall Window Condition Assessment - 48
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
375a<br />
377a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good, vertical<br />
blinds<br />
attached at<br />
top<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, some excellent yes no good west yes<br />
moss<br />
accumulation<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes, top sinks no good west<br />
380a<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
dropped good, minor<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
excellent yes no excellent east<br />
380b<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
dropped good, minor<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
excellent yes no excellent east attachemnts remain for<br />
unknown object in<br />
header<br />
yes<br />
380c<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
dropped good, minor<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
excellent yes no excellent east<br />
Straub Hall Window Condition Assessment - 49
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
380d<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
dropped excellent new lock on yes no excellent east<br />
ceiling<br />
lower right<br />
attached to<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
381a<br />
382a<br />
383a<br />
S384a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
double hung good, some<br />
16 pane chipping<br />
w/wood<br />
muntins,<br />
opening from<br />
bottom<br />
good, roll<br />
down blinds<br />
attached at<br />
top of case<br />
good, lower 8<br />
panels have<br />
been painted<br />
white and<br />
urinal is<br />
attached to<br />
front of<br />
case/stool<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good, moss<br />
accumulation<br />
excellent yes no good west<br />
excellent excellent top window<br />
sits on<br />
exterior<br />
supports for<br />
ventilation,<br />
bottom is<br />
fixed<br />
good, some<br />
moss<br />
accumulation<br />
both weight<br />
cords are<br />
broken<br />
no, because<br />
of lack of<br />
cords<br />
no good east<br />
no good west yes<br />
good excellent good yes no excellent east yes<br />
Straub Hall Window Condition Assessment - 50
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
385a double hung<br />
w/wood<br />
muntins<br />
385b<br />
386a<br />
387a<br />
387Aa<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
excellent<br />
good, some<br />
chipping<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
Window<br />
Parts*<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good, blinds<br />
attached at<br />
top, crack in<br />
stool<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, minor excellent yes, top sinks no good west<br />
moss<br />
accumulation<br />
good, moss<br />
accumulation<br />
good, moss<br />
accumulation<br />
good, minor<br />
moss<br />
accumulation<br />
excellent<br />
not<br />
accessible<br />
no good south<br />
excellent yes no fair south yes<br />
missing<br />
right pull<br />
yes, but the<br />
top drops<br />
when<br />
unlocked,<br />
bottom is<br />
stuck<br />
excellent excellent yes, top sinks no excellent south<br />
no good south yes<br />
Straub Hall Window Condition Assessment - 51
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
388a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
bottom<br />
casing and<br />
stool have<br />
been<br />
removed, and<br />
major cracks<br />
appear in<br />
remaining<br />
case<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
good, minor<br />
moss<br />
accumulation<br />
Facing<br />
Elev. Comments Photo<br />
excellent yes no fair north bottom of casing has yes<br />
been removed and will<br />
have to be<br />
reconstructed<br />
388b<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
bottom good, moss<br />
casing and accumulation<br />
stool have<br />
been<br />
removed, and<br />
major cracks<br />
appear in<br />
remaining<br />
case<br />
excellent yes no fair north bottom of casing has<br />
been removed and will<br />
have to be<br />
reconstructed<br />
yes<br />
389a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, one glass<br />
pane cracked<br />
excellent excellent yes, top sinks no good south yes<br />
H389a<br />
Picture<br />
window with<br />
awning, 12<br />
panes and<br />
wood<br />
muntins<br />
excellent good good, moss<br />
accumulation<br />
good yes no excellent north yes<br />
Straub Hall Window Condition Assessment - 52
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
390a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
excellent<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
dropped good, minor excellent yes no excellent north<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
390b<br />
stacked excellent<br />
wood<br />
awning<br />
window with<br />
muntins<br />
dropped good, minor<br />
ceiling moss<br />
attached to accumulation<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
slide lock<br />
disabled,<br />
new side<br />
lock<br />
yes, now<br />
operates as a<br />
casement<br />
window<br />
no good north altered from original<br />
configuration<br />
yes<br />
391a<br />
392a<br />
double hung<br />
w/wood<br />
muntins<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
excellent<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good, some<br />
spalling of<br />
bricks<br />
excellent yes no excellent south<br />
dropped<br />
ceiling<br />
attached to<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
good excellent yes no excellent north<br />
Straub Hall Window Condition Assessment - 53
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
392b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
excellent<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
dropped good excellent yes not excellent<br />
ceiling<br />
accessibl<br />
attached to<br />
e<br />
upper casing,<br />
horizontal<br />
blinds<br />
attached<br />
Facing<br />
Elev. Comments Photo<br />
north<br />
393a<br />
394a<br />
double hung<br />
w/wood<br />
muntins<br />
16 pane,<br />
double hung<br />
w/ wood<br />
muntins<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, a few<br />
cracks in<br />
glass<br />
excellent good, lower 8<br />
panels have<br />
been painted<br />
white<br />
good, minor<br />
moss<br />
accumulation<br />
good, some<br />
moss<br />
accumulation<br />
excellent yes no good south<br />
broken left<br />
cord<br />
bottom is<br />
non-operable<br />
but top sinks<br />
2" resting on<br />
unseen<br />
exterior<br />
supports<br />
no good north yes<br />
395a<br />
397a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good, one<br />
muntin<br />
severely<br />
deteriorated<br />
good, minor<br />
moss<br />
accumulation<br />
good, some<br />
moss<br />
accumulation<br />
missing left<br />
weight cord<br />
both weight<br />
cords are<br />
broken<br />
yes, top sinks no good south<br />
yes, top sinks no good south yes<br />
Straub Hall Window Condition Assessment - 54
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
397b<br />
398a<br />
398b<br />
S398a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
excellent<br />
double hung, excellent<br />
rounded<br />
arch, 32 pane<br />
w/wood<br />
muntins<br />
Window<br />
Parts*<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
casing is<br />
cracking at<br />
top right and<br />
mid-arch<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, moss missing left not no good east<br />
accumulation weight cord accessible<br />
good, moss<br />
accumulation<br />
good, some<br />
moss<br />
accumulation<br />
good, some<br />
moss<br />
accumulation<br />
excellent yes no good east yes<br />
broken right<br />
weight cord<br />
broken left<br />
cord<br />
yes no good north yes<br />
no no good north This is a double height<br />
window and is also<br />
qualified as S498a<br />
yes<br />
401a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
excellent excellent excellent new lock<br />
and pull<br />
yes no excellent south this window appears to yes<br />
have been reconstructed<br />
recently<br />
401b<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, vertical<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
case<br />
excellent excellent yes no good north yes<br />
Straub Hall Window Condition Assessment - 55
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
401Aa double hung<br />
w/wood<br />
muntins<br />
Conditions<br />
Paint<br />
poor, sill w/out<br />
paint, deep<br />
flaking on<br />
exterior casing,<br />
interior muntins<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
Window<br />
Parts*<br />
splitting in<br />
case, large<br />
chunk<br />
missing from<br />
upper left<br />
case<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, some excellent not no fair south yes<br />
concrete<br />
accessible<br />
401Ab<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping, some<br />
moisture<br />
damage on<br />
muntins<br />
good, vertical<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
case<br />
excellent excellent yes no good east<br />
401Ac<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, vertical<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
case<br />
excellent excellent yes no excellent east<br />
401Ad<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, vertical<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
case<br />
excellent<br />
broken right<br />
weight cord<br />
no no good north yes<br />
H402a<br />
stacked excellent, dark<br />
wood brown rather<br />
awning than salmon or<br />
window with white<br />
muntins<br />
excellent excellent new lock<br />
and pull<br />
no, taped off no excellent south yes<br />
Straub Hall Window Condition Assessment - 56
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
404a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Conditions<br />
Paint<br />
poor, sill w/out<br />
paint, deep<br />
flaking on<br />
exterior casing,<br />
interior muntins<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
Window<br />
Parts*<br />
poor, sash<br />
and muntins<br />
are damaged<br />
(condensatio<br />
n<br />
accumulation<br />
)<br />
Brick Sill<br />
Facing<br />
Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
excellent excellent yes yes fair south yes<br />
404b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
poor, sill w/out<br />
paint, deep<br />
flaking on<br />
exterior casing,<br />
interior muntins<br />
showing signs<br />
of past<br />
condensation<br />
accumulation<br />
poor, sash<br />
and muntins<br />
are damaged<br />
(condensatio<br />
n<br />
accumulation<br />
)<br />
excellent excellent yes yes fair south yes<br />
405a<br />
406a<br />
407a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping<br />
excellent,<br />
vertical<br />
blinds<br />
attached<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good, minor<br />
splitting in<br />
case<br />
excellent excellent not<br />
accessible<br />
no excellent north<br />
excellent new lock yes no excellent south<br />
excellent<br />
broken right<br />
weight cord<br />
no no good north<br />
Straub Hall Window Condition Assessment - 57
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
408a<br />
408b<br />
408c<br />
408d<br />
409a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Conditions<br />
Paint<br />
fair, paint<br />
generally in<br />
good condition<br />
except for<br />
sash/muntins<br />
showing signs<br />
of moisture<br />
damage<br />
stacked fair, paint<br />
wood generally in<br />
awning good condition<br />
window with except for<br />
muntins sash/muntins<br />
showing signs<br />
of moisture<br />
damage<br />
stacked fair, paint<br />
wood generally in<br />
awning good condition<br />
window with except for<br />
muntins sash/muntins<br />
showing signs<br />
of moisture<br />
damage<br />
stacked fair, paint<br />
wood generally in<br />
awning good condition<br />
window with except for<br />
muntins sash/muntins<br />
showing signs<br />
of moisture<br />
damage<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
good, some<br />
signs of<br />
moisture<br />
damage<br />
good, some<br />
signs of<br />
moisture<br />
damage<br />
good, some<br />
signs of<br />
moisture<br />
damage<br />
good, some<br />
signs of<br />
moisture<br />
damage<br />
good, minor<br />
splitting in<br />
case<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent not no good south<br />
accessible<br />
excellent excellent not<br />
accessible<br />
excellent excellent yes no good south<br />
excellent excellent yes no good south<br />
good, some<br />
moss<br />
accumulation<br />
yes fair south yes<br />
excellent yes no excellent north yes<br />
S410a **see S310a** south<br />
Straub Hall Window Condition Assessment - 58
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
411a double hung<br />
w/wood<br />
muntins<br />
Paint<br />
excellent<br />
Window<br />
Parts*<br />
excellent, roll<br />
down blinds<br />
attached<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent yes, top sinks no excellent north<br />
413a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good amount excellent excellent yes no good north yes<br />
of splitting in<br />
case<br />
419a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no excellent north<br />
H419a **see H319a** east<br />
420a<br />
420b<br />
420c<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, some<br />
chipping, some<br />
moisture<br />
damage on<br />
muntins<br />
good, some<br />
chipping, some<br />
moisture<br />
damage on<br />
muntins<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, cracking<br />
in exterior<br />
sash<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no excellent north<br />
excellent excellent not<br />
accessible<br />
no good west yes<br />
excellent excellent yes no good west yes<br />
Straub Hall Window Condition Assessment - 59
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
422a<br />
423a<br />
424a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Conditions<br />
Paint<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
stacked good, some<br />
wood chipping, some<br />
awning moisture<br />
window with damage on<br />
muntins muntins<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, lower 8 not accessible missing left top window not good east restroom<br />
panels have<br />
pull sits on accessibl<br />
been painted<br />
exterior e<br />
white<br />
supports for<br />
ventilation,<br />
bottom is<br />
fixed<br />
good, good, minor excellent not no good west yes<br />
horizontal moss<br />
accessible<br />
blinds accumulation<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
signs of<br />
moisture<br />
damage on<br />
sash and<br />
muntins<br />
excellent excellent yes no good east<br />
424b<br />
stacked good, some<br />
wood chipping, some<br />
awning moisture<br />
window with damage on<br />
muntins muntins<br />
signs of<br />
moisture<br />
damage on<br />
sash and<br />
muntins<br />
excellent excellent yes no good east<br />
425a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
excellent excellent yes no good west<br />
Straub Hall Window Condition Assessment - 60
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
425b<br />
426a<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, excellent excellent yes no good west<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good, vertical excellent no pull not no fair east yes<br />
blinds<br />
accessible<br />
attached at<br />
top, crack in<br />
stool<br />
426b<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
good, vertical<br />
blinds<br />
attached at<br />
top<br />
excellent excellent yes no good east<br />
427a<br />
H427a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
stacked excellent, dark<br />
wood brown rather<br />
awning than salmon or<br />
window with white<br />
muntins<br />
splitting in<br />
case,<br />
chipping in<br />
sash and<br />
muntins<br />
excellent,<br />
shared<br />
casement<br />
with fire door<br />
excellent<br />
right weight<br />
cord needs<br />
to be<br />
replaced<br />
excellent excellent no, painted<br />
into place<br />
yes no good west yes<br />
no good east yes<br />
428a<br />
stacked good, some<br />
wood chipping on<br />
awning interior,<br />
window with extensive<br />
muntins chipping on<br />
exterior<br />
good, vertical<br />
blinds<br />
attached at<br />
top<br />
excellent excellent yes no excellent east<br />
Straub Hall Window Condition Assessment - 61
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
428b<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Conditions<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, vertical excellent excellent yes no excellent east<br />
blinds<br />
attached at<br />
top<br />
429a not accessible not accessible not accessible not accessible not<br />
accessible<br />
not<br />
accessible<br />
not not<br />
accessibl accessible<br />
e<br />
S430 **see S330a** east<br />
west<br />
431a<br />
H432a<br />
433a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
12 pane w/<br />
wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
excellent, dark<br />
brown rather<br />
than salmon or<br />
white, exterior<br />
has some<br />
chipping<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, roll<br />
down blinds<br />
attached at<br />
top of case,<br />
some<br />
splitting in<br />
case<br />
excellent,<br />
shared<br />
casement<br />
with fire door<br />
good, vertical<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
case<br />
good, minor<br />
moss<br />
accumulation<br />
excellent<br />
excellent no no good west yes<br />
missing pull no, painted<br />
into place<br />
no good east yes<br />
excellent excellent yes no good west yes<br />
Straub Hall Window Condition Assessment - 62
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
435a<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
some excellent excellent yes no good west yes<br />
splitting in<br />
case, also<br />
signs of past<br />
condensation<br />
accumulation<br />
on the lower<br />
muntins<br />
441a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, one glass<br />
pane cracked<br />
excellent excellent yes no excellent west<br />
H442a<br />
443a<br />
443b<br />
stacked excellent, dark<br />
wood brown rather<br />
awning than salmon or<br />
window with white, exterior<br />
muntins has some<br />
chipping<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
excellent excellent pull is of a no, painted<br />
different sort into place<br />
than the rest<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
excellent excellent not<br />
accessible<br />
excellent excellent not<br />
accessible<br />
no good east yes<br />
no excellent west<br />
no good west<br />
Straub Hall Window Condition Assessment - 63
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
444a<br />
444b<br />
445a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
stacked good, some<br />
wood chipping on<br />
awning interior,<br />
window with extensive<br />
muntins chipping on<br />
exterior<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
signs on past<br />
condensation<br />
accumulation<br />
Brick Sill<br />
Facing<br />
Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
excellent excellent yes no good east<br />
excellent excellent yes no good east<br />
good, some<br />
moss<br />
accumulation<br />
excellent<br />
not<br />
accessible<br />
no good west<br />
451a<br />
double hung<br />
w/wood<br />
muntins<br />
excellent<br />
interior, some<br />
chipping on<br />
exterior<br />
good, vertical<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
case<br />
good, minor<br />
moss<br />
accumulation<br />
left weight<br />
cord broken<br />
no no good west<br />
Straub Hall Window Condition Assessment - 64
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
446a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Conditions<br />
Paint<br />
good, some<br />
chipping, some<br />
moisture<br />
damage on<br />
muntins<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, vertical excellent pull on yes no good east<br />
blinds<br />
upper<br />
attached at<br />
awning<br />
top<br />
broken<br />
446b<br />
stacked good, some<br />
wood chipping, some<br />
awning moisture<br />
window with damage on<br />
muntins muntins<br />
good, vertical<br />
blinds<br />
attached at<br />
top<br />
excellent excellent yes no good east<br />
448a<br />
448b<br />
stacked good, some<br />
wood chipping, some<br />
awning moisture<br />
window with damage on<br />
muntins muntins<br />
stacked good, some<br />
wood chipping, some<br />
awning moisture<br />
window with damage on<br />
muntins muntins<br />
good, some<br />
signs of<br />
moisture<br />
damage<br />
good, some<br />
signs of<br />
moisture<br />
damage<br />
excellent excellent yes no fair east yes<br />
excellent excellent yes no fair east<br />
450a<br />
stacked good, some<br />
wood chipping, some<br />
awning moisture<br />
window with damage on<br />
muntins muntins<br />
good, some<br />
signs of<br />
moisture<br />
damage<br />
excellent excellent not<br />
accessible<br />
no good east<br />
450b<br />
stacked good, some<br />
wood chipping, some<br />
awning moisture<br />
window with damage on<br />
muntins muntins<br />
good, some<br />
signs of<br />
moisture<br />
damage<br />
excellent excellent not<br />
accessible<br />
no good east<br />
Straub Hall Window Condition Assessment - 65
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
452a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, vertical excellent excellent yes no excellent east<br />
blinds<br />
attached at<br />
top<br />
452b<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
good, vertical<br />
blinds<br />
attached at<br />
top<br />
excellent<br />
new pull on<br />
upper<br />
awning<br />
yes no excellent east<br />
453a<br />
453b<br />
454a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good, some<br />
signs of<br />
moisture<br />
damage<br />
excellent no lock yes no excellent west<br />
excellent excellent not<br />
accessible<br />
no good west<br />
excellent excellent yes no excellent east yes<br />
454b<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
excellent excellent excellent yes no excellent east<br />
Straub Hall Window Condition Assessment - 66
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
455a<br />
H455a<br />
456a<br />
457a<br />
457b<br />
458a<br />
double hung<br />
w/wood<br />
muntins<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Conditions<br />
Paint<br />
excellent<br />
interior, some<br />
chipping on<br />
exterior<br />
excellent, dark<br />
brown rather<br />
than salmon or<br />
white, exterior<br />
has some<br />
chipping<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
good, some<br />
chipping<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent, excellent excellent yes no excellent west<br />
with scars<br />
from lock<br />
hitting<br />
muntins<br />
excellent excellent excellent yes no excellent east yes<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, cracking<br />
in stool<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
excellent excellent yes no excellent east<br />
excellent excellent not<br />
accessible<br />
excellent<br />
both weight<br />
cords are<br />
broken<br />
no excellent west<br />
no no good west yes<br />
excellent excellent yes no good east<br />
Straub Hall Window Condition Assessment - 67
* All parts in excellent condition otherwise unless mentioned<br />
Window Window<br />
# T y p e<br />
459a<br />
470a<br />
470b<br />
double hung<br />
w/wood<br />
muntins<br />
Conditions<br />
Paint<br />
good, some<br />
chipping<br />
stacked good, some<br />
wood chipping on<br />
awning interior,<br />
window with extensive<br />
muntins chipping on<br />
exterior, with<br />
signs of past<br />
condensation<br />
accumulation<br />
stacked good, some<br />
wood chipping on<br />
awning interior,<br />
window with extensive<br />
muntins chipping on<br />
exterior, with<br />
signs of past<br />
condensation<br />
accumulation<br />
Window<br />
Parts*<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top, some<br />
splitting in<br />
casing<br />
good, some<br />
signs of<br />
moisture<br />
damage<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
Brick Sill<br />
Facing<br />
Condition Hardware Operability Dry Rot Overall Elev. Comments Photo<br />
excellent excellent yes no good west<br />
excellent excellent yes no good east<br />
excellent excellent yes no excellent east<br />
S470a **see S370a** east<br />
471a<br />
H472a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
excellent excellent excellent not<br />
accessible<br />
no excellent west<br />
excellent excellent excellent yes no excellent east yes<br />
Straub Hall Window Condition Assessment - 68
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
473a<br />
474a<br />
double hung<br />
w/wood<br />
muntins<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
good, some<br />
chipping, some<br />
moisture<br />
damage on<br />
muntins<br />
Window<br />
Parts*<br />
good, minor<br />
splitting in<br />
case<br />
cracking/chi<br />
pping in<br />
exterior sash<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent yes no good west<br />
excellent excellent yes no good east<br />
474b<br />
stacked<br />
wood<br />
severe flaking<br />
seems to be<br />
cracking/chi<br />
pping in<br />
awning caused by water exterior sash<br />
window with /condensation<br />
muntins<br />
excellent excellent yes no good east yes<br />
475a<br />
476a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
stacked excellent<br />
wood interior, some<br />
awning chipping on<br />
window with exterior<br />
muntins<br />
excellent excellent excellent yes no excellent west<br />
excellent excellent excellent yes no excellent east<br />
(new chains)<br />
476b<br />
stacked excellent<br />
wood interior, some<br />
awning chipping on<br />
window with exterior<br />
muntins<br />
excellent,<br />
some<br />
cracking on<br />
exterior sash<br />
excellent excellent yes no excellent east<br />
477a<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good amount excellent excellent yes no good west yes<br />
of splitting in<br />
case<br />
Straub Hall Window Condition Assessment - 69
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
478a<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, lower 8 excellent excellent yes, sticky no good east restroom - wood panels yes<br />
panels have<br />
needed for privacy<br />
been painted<br />
white<br />
480a<br />
483a<br />
483b<br />
483c<br />
484a<br />
S484a<br />
485a<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
excellent<br />
interior, some<br />
chipping on<br />
exterior<br />
excellent<br />
excellent<br />
excellent<br />
interior, some<br />
chipping on<br />
exterior<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, minor<br />
splitting in<br />
case<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
excellent,<br />
horizontal<br />
blinds<br />
attached, a<br />
few dents<br />
excellent<br />
broken left<br />
weight cord<br />
not<br />
accessible<br />
excellent excellent not<br />
accessible<br />
no good west<br />
no excellent west<br />
excellent excellent yes no excellent west<br />
good, some<br />
moss<br />
accumulation<br />
good, some<br />
moss<br />
accumulation<br />
excellent yes no excellent south<br />
excellent yes no good south yes<br />
fair excellent excellent yes no good east scars from relpaced<br />
sections and lock<br />
damage seen on<br />
casement<br />
good, minor excellent excellent yes no good south<br />
splitting in<br />
case<br />
yes<br />
Straub Hall Window Condition Assessment - 70
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
487a<br />
488a<br />
double hung<br />
w/wood<br />
muntins<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
excellent<br />
Window<br />
Parts*<br />
chips and<br />
cracks in<br />
stool and<br />
lower<br />
muntins/sas<br />
h<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
excellent excellent yes no good south yes<br />
excellent excellent yes no excellent north<br />
488b<br />
stacked excellent<br />
wood<br />
awning<br />
window with<br />
muntins<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
good, minor<br />
moss<br />
accumulation<br />
excellent yes no excellent north<br />
489a<br />
H489a<br />
double hung<br />
w/wood<br />
muntins<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
major<br />
splitting in<br />
meeting rail<br />
excellent excellent good, some<br />
moss<br />
accumulation<br />
excellent excellent no no fair south yes<br />
excellent yes no excellent north yes<br />
490a<br />
stacked excellent<br />
wood<br />
awning<br />
window with<br />
muntins<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
excellent excellent yes no excellent north<br />
Straub Hall Window Condition Assessment - 71
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
490b<br />
491a<br />
stacked<br />
wood<br />
awning<br />
window with<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
excellent<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior, with<br />
signs of past<br />
condensation<br />
accumulation<br />
Window<br />
Parts*<br />
joined at the<br />
middle,<br />
opening at<br />
the right<br />
some<br />
splitting in<br />
case, also<br />
signs of past<br />
condensation<br />
accumulation<br />
on the lower<br />
muntins<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
excellent slider and<br />
new lock at<br />
middle right<br />
Facing<br />
Elev. Comments Photo<br />
yes<br />
yes no good/fair north this window was<br />
originally a stacked<br />
awning configuration,<br />
and has been sealed at<br />
the meeting to now<br />
operate as a casement<br />
window<br />
excellent excellent yes no good south yes<br />
492a<br />
stacked good, some<br />
wood chipping<br />
awning<br />
window with<br />
muntins<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
excellent excellent yes no excellent north<br />
492b<br />
stacked excellent<br />
wood<br />
awning<br />
window with<br />
muntins<br />
good,<br />
horizontal<br />
blinds<br />
attached at<br />
top<br />
excellent excellent yes no excellent north<br />
Straub Hall Window Condition Assessment - 72
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
493a<br />
double hung<br />
w/wood<br />
muntins<br />
Paint<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior, with<br />
signs of past<br />
condensation<br />
accumulation<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
some excellent excellent yes no good south<br />
splitting in<br />
case, also<br />
signs of past<br />
condensation<br />
accumulation<br />
on the lower<br />
muntins<br />
494a<br />
497a<br />
497b<br />
497c<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
double hung<br />
w/wood<br />
muntins<br />
good, some<br />
chipping<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
good, some<br />
chipping on<br />
interior,<br />
extensive<br />
chipping on<br />
exterior<br />
all panels<br />
painted<br />
white, urinal<br />
attached to<br />
case at lower<br />
right<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
not accessible<br />
excellent<br />
wood blocks<br />
around<br />
weight<br />
cords, right<br />
weight cord<br />
broken<br />
missing lock,<br />
broken left<br />
weight cord<br />
top window<br />
sits on<br />
exterior<br />
supports for<br />
ventilation,<br />
bottom is<br />
fixed<br />
not<br />
accessibl<br />
e<br />
no no good south<br />
excellent excellent yes no excellent south<br />
good, minor<br />
moss<br />
accumulation<br />
broken lach<br />
for lock<br />
yes no excellent east<br />
fair north yes<br />
Straub Hall Window Condition Assessment - 73
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e Paint<br />
498a double hung good, some<br />
w/wood chipping on<br />
muntins interior,<br />
extensive<br />
chipping on<br />
exterior<br />
498b double hung good, some<br />
w/wood chipping on<br />
muntins interior,<br />
extensive<br />
chipping on<br />
exterior<br />
S498a **see S398a**<br />
Window<br />
Parts*<br />
excellent,<br />
horizontal<br />
blinds<br />
attached<br />
splitting in<br />
case<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
Facing<br />
Elev. Comments Photo<br />
good, minor excellent yes no good east<br />
moss<br />
accumulation<br />
excellent excellent not<br />
accessible<br />
no good north<br />
Sky1<br />
Sky2<br />
Skylight<br />
domed<br />
Skylight<br />
domed<br />
lots of flaking<br />
on interior<br />
fair NA none no not able<br />
to<br />
thorough<br />
ly assess<br />
good<br />
excellent fair NA none no not able<br />
to<br />
thorough<br />
ly assess<br />
excellent<br />
peeling interior paint yes<br />
indicates possible water<br />
infiltration or<br />
condensation<br />
accumulation. Opening<br />
covered on interior with<br />
vent and dropped<br />
ceiling.<br />
Sky3<br />
Skylight<br />
straight gable<br />
excellent fair NA none no not able<br />
to<br />
thorough<br />
ly assess<br />
good<br />
some mildew at joints,<br />
sealant compromised<br />
Sky4<br />
Skylight<br />
domed<br />
excellent fair NA none no not able<br />
to<br />
thorough<br />
ly assess<br />
excellent<br />
Straub Hall Window Condition Assessment - 74
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
Sky5 Skylight<br />
domed<br />
Paint<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
excellent fair NA none no not able excellent<br />
to<br />
thorough<br />
ly assess<br />
Facing<br />
Elev. Comments Photo<br />
Sky6<br />
Skylight<br />
domed<br />
excellent fair NA none no not able<br />
to<br />
thorough<br />
ly assess<br />
excellent<br />
Sky7<br />
Skylight<br />
straight gable<br />
excellent fair NA none no not able<br />
to<br />
thorough<br />
ly assess<br />
fair to poor<br />
large amount of mildew<br />
at joints, sealant<br />
compromised<br />
yes<br />
Sky8<br />
Skylight<br />
domed<br />
excellent fair NA none no not able<br />
to<br />
thorough<br />
ly assess<br />
excellent<br />
Sky9<br />
Sky10<br />
Skylight<br />
domed<br />
Skylight<br />
domed<br />
lots of flaking<br />
on interior<br />
fair NA none no not able<br />
to<br />
thorough<br />
ly assess<br />
good<br />
excellent fair NA none no not able<br />
to<br />
thorough<br />
ly assess<br />
excellent<br />
peeling interior paint<br />
indicates possible water<br />
infiltration or<br />
condensation<br />
accumulation. Opening<br />
enclosed by dropped<br />
ceiling.<br />
yes<br />
Sky11<br />
Skylight<br />
domed<br />
excellent fair NA none no not able<br />
to<br />
thorough<br />
ly assess<br />
good<br />
peeling interior paint<br />
indicates possible water<br />
infiltration or<br />
condensation<br />
accumulation.<br />
Straub Hall Window Condition Assessment - 75
* All parts in excellent condition otherwise unless mentioned<br />
Conditions<br />
Window Window<br />
# T y p e<br />
Sky12 Skylight<br />
domed<br />
Paint<br />
lots of flaking<br />
on interior<br />
Window<br />
Parts*<br />
Brick Sill<br />
Condition Hardware Operability Dry Rot Overall<br />
fair NA none no not able excellent<br />
to<br />
thorough<br />
ly assess<br />
Facing<br />
Elev. Comments Photo<br />
peeling interior paint<br />
indicates possible water<br />
infiltration or<br />
condensation<br />
accumulation.<br />
Straub Hall Window Condition Assessment - 76
30Ab ^<br />
28Aa ^<br />
B<br />
30Aa ^<br />
Straub Hall Window Condition Assessment - 77
178c ^<br />
^ 152Ba<br />
170a ><br />
1 Straub Hall Window Condition Assessment - 78
^ 202b<br />
^ 274a<br />
^ 204b<br />
^ S290a<br />
^ 208a<br />
2<br />
^ 204a<br />
Straub Hall Window Condition Assessment - 79
^ 304a<br />
^ 310b<br />
^ H331a<br />
< 344b<br />
308a ><br />
3 Straub Hall Window Condition Assessment - 80
^ 404a<br />
413a ^<br />
4<br />
426a ><br />
Straub Hall Window Condition Assessment - 81
^ Sky #7<br />
Sky #1 ^<br />
^ Sky #7 ^ Sky #7 Sky #1 ^<br />
R<br />
Straub Hall Window Condition Assessment - 82
051b<br />
051a<br />
030Aa X<br />
030Ab X<br />
028a<br />
028b<br />
028c<br />
025a<br />
Straub Hall Window Condition Assessment - 83
109c 109b 109a<br />
156Dd 156Db<br />
156Dc<br />
199Aa<br />
199b<br />
111a<br />
111b<br />
113a<br />
119b<br />
119c<br />
122a<br />
122b<br />
122c<br />
109d<br />
109e<br />
122d<br />
105a<br />
S113a<br />
119a<br />
126a<br />
S120a<br />
129a<br />
127a<br />
131a 131b<br />
168Ca<br />
168Cb<br />
142c<br />
142d<br />
128a 130a S130a<br />
142a<br />
142b<br />
137a<br />
139a<br />
139b<br />
146b<br />
141a<br />
140a<br />
146a<br />
155b<br />
155a<br />
154a<br />
S170a<br />
156Da<br />
156Ba<br />
178Aa<br />
178a<br />
199Ab<br />
152Aa<br />
152Ba<br />
153a 170a 172a 178b 178c 180b 180c<br />
S198a<br />
196a<br />
195a<br />
193a<br />
191a<br />
180a<br />
186a<br />
199a<br />
194a<br />
189b<br />
189a<br />
186b<br />
Straub Hall Window Condition Assessment - 84
Straub Hall Window Condition Assessment - 85<br />
L150c<br />
L150a<br />
L150b<br />
283b<br />
253a<br />
251a<br />
255a<br />
257a<br />
271a<br />
273a<br />
279b<br />
279a<br />
283a<br />
243a<br />
229a<br />
231a<br />
233a<br />
237a 239a 241a<br />
245a<br />
227a<br />
209a<br />
211a<br />
212a<br />
220a<br />
221a<br />
221b<br />
207a<br />
205a<br />
202a<br />
208a<br />
S230a<br />
230a<br />
228a<br />
228b<br />
224a<br />
210d<br />
210c<br />
210b<br />
210a<br />
S210a<br />
298a<br />
S290a<br />
294a<br />
292a<br />
292b<br />
290a<br />
290b<br />
S284a<br />
278b 278a<br />
272a<br />
272b<br />
270a<br />
270b<br />
S270a<br />
298b<br />
287a<br />
293a<br />
295c<br />
295b<br />
295a<br />
259a<br />
235a<br />
225a<br />
H219a<br />
226a<br />
226b<br />
232a<br />
232b<br />
H236a<br />
238a<br />
240a<br />
240b<br />
242a<br />
242b<br />
252a<br />
254a<br />
256a<br />
258a<br />
274a<br />
H286a<br />
H286b<br />
H286c<br />
288a<br />
289a<br />
291a<br />
H202a<br />
204b<br />
204a<br />
203a<br />
201a<br />
201b<br />
223a<br />
284a<br />
284b
309a<br />
311a<br />
312a<br />
320a<br />
321a<br />
301a<br />
301b<br />
303a<br />
305a<br />
307a<br />
321b<br />
302b<br />
310d<br />
310c<br />
310b<br />
310a<br />
323a<br />
302a<br />
H302a<br />
304b<br />
304a<br />
308a<br />
S310a<br />
H319<br />
325a<br />
324a<br />
327a<br />
326a<br />
326b<br />
328a<br />
328b<br />
329a<br />
H331a<br />
331a<br />
332a<br />
332b<br />
333a<br />
S330a<br />
335a<br />
H336a<br />
338a<br />
337a 337b339a<br />
H340a<br />
342a<br />
342b<br />
341a<br />
344a<br />
344b<br />
343a<br />
346a<br />
346b<br />
345a<br />
348a 352a<br />
348b 352b<br />
350a<br />
350b 354a<br />
347a<br />
349a<br />
351a 353a<br />
356a<br />
355a<br />
358a<br />
357a<br />
S370a<br />
359a<br />
370a<br />
370b<br />
371a<br />
H372a<br />
373a<br />
380c 380a<br />
380d 380b382a<br />
375a<br />
377a<br />
398b<br />
398a<br />
S384a<br />
381a<br />
S398a<br />
394a<br />
392a<br />
392b<br />
H389a<br />
390a<br />
390b<br />
388a<br />
388b<br />
397a<br />
383a 385a<br />
386a<br />
385b<br />
397b<br />
395a<br />
393a<br />
391a<br />
389a<br />
387Aa<br />
387a<br />
Straub Hall Window Condition Assessment - 86
401Ac<br />
401Ad<br />
409a<br />
411a<br />
413a<br />
419a<br />
401b<br />
405a<br />
407a<br />
401Ab<br />
408d<br />
408c<br />
408b<br />
408a<br />
401Aa<br />
401a<br />
H402a<br />
404b<br />
404a<br />
406a<br />
S410a<br />
422a 426a<br />
426b<br />
424a<br />
H419a 424b H427a<br />
428a<br />
428b<br />
S430a<br />
H432a<br />
H442a 446a<br />
446b<br />
450a<br />
450b<br />
454a<br />
454b<br />
444a<br />
444b<br />
448a<br />
448b<br />
452a<br />
452b H455a<br />
498b<br />
S498a<br />
494a<br />
492a<br />
492b<br />
H489a<br />
H472a<br />
490a<br />
490b<br />
456a S470a 474a 476a 478a488a<br />
488b<br />
458a<br />
470a<br />
470b 474b 476b S484a<br />
498a<br />
497c<br />
497b<br />
497a<br />
493a<br />
491a<br />
489a<br />
487a<br />
485a<br />
484a<br />
420a<br />
420b<br />
420c<br />
423a<br />
425b 429a<br />
425a 427a<br />
431a<br />
433a 435a 441a<br />
443a<br />
443b<br />
445a<br />
451a<br />
453a<br />
457a<br />
459a<br />
453b 455a 457b<br />
471a<br />
473a<br />
475a<br />
477a<br />
480a<br />
483a 483b<br />
483c<br />
Straub Hall Window Condition Assessment - 87
Sky1<br />
Sky12<br />
Sky11<br />
Sky9<br />
Sky10<br />
Sky2<br />
Sky8<br />
Sky3<br />
Sky7<br />
Sky4 Sky5 Sky6<br />
Straub Hall Window Condition Assessment - 88
UO Straub Hall - Deferred Maintenance and Seismic Upgrade 1 of 3<br />
PART 1 - GENERAL<br />
1.01 SUMMARY<br />
SECTION 06 6100<br />
ARCHITECTURAL FIBERGLASS<br />
A. Section Includes:<br />
1. Fabrication of fiberglass - reinforced polyester replicas of existing masonry chimneys.<br />
B. Related Documents and Sections:<br />
1. General Conditions, Supplementary Conditions and Division 1 General Requirements apply<br />
to the work of this section.<br />
2. Section 06 1000, “Rough Carpentry”, for support frame and blocking.<br />
3. Section 07 6200, “Sheet Metal Flashing and Trim”.<br />
4. Section 07 9005, “Joint Sealants”.<br />
1.02 QUALITY ASSURANCE<br />
A. The fiberglass manufacturer shall be one who is currently in the business of manufacturing and<br />
supplying architectural fiberglass components for the building construction industry and who can<br />
demonstrate the capability.<br />
B. The fiberglass manufacturer shall have been engaged in the fiberglass industry for at least 10<br />
years doing work with projects comparable in size, scope, detail, and complexity to that shown<br />
and specified.<br />
1. Submit a list of comparable projects, locations, and owner contacts with bid documents.<br />
C. Single Source Responsibility for Architectural Fiberglass: Obtain architectural fiberglass from a<br />
single source with resources to provide products complying with requirements indicated without<br />
delaying the work.<br />
D. Fire Test Response Characteristics: Provide architectural fiberglass and related materials with<br />
fire test response characteristics as specified elsewhere in this section as determined by testing<br />
identical products per test method ASTM E-84 or other testing and inspecting agency<br />
acceptable to authorities having jurisdiction. Provide written certification that supplied<br />
architectural fiberglass panels meets or exceeds the criteria.<br />
1.03 1.03 SUBMITTALS<br />
A. Qualification Data for firms and persons specified in the “Quality Assurance” Article to<br />
demonstrate their capabilities and experience. Include lists of completed projects with project<br />
names and addresses, names and addresses of architects and owners, and other information<br />
specified.<br />
B. Color Selection:<br />
1. Submit custom color sample selection chips of actual material showing color, texture and<br />
sheen available for initial review.<br />
a. Custom paint color samples to be based on existing masonry chimneys.<br />
C. Shop Drawings:<br />
1. Submit shop drawings for fabrication and erection. Include plans, elevations, sections,<br />
profiles, and details of Chimney reproductions. Indicate dimensions of each profile and<br />
component. Include for comparison a dimensioned drawing showing plan elevation<br />
section and details of existing Chimney used for model purposes if applicable. Indicate<br />
those features, which differ from fiberglass replication. Include details for connections,<br />
anchorage to substructure and all miscellaneous accessories. Show all special<br />
fabrications.<br />
D. Samples:<br />
1. Submit sample Chimney corner section, minimum 18” high by 12” in each plan direction<br />
including step in existing Chimney profile. Construct sample panel to show connection<br />
points, embedded connection and reinforcing clips, include typical fasteners to complete<br />
the submission.<br />
<strong>Addendum</strong> B 06 6100<br />
May 24, 2013<br />
ARCHITECTURAL FIBERGLASS
UO Straub Hall - Deferred Maintenance and Seismic Upgrade 2 of 3<br />
E. Submit detailed maintenance instructions for inclusion in final operation and maintenance<br />
manuals.<br />
F. Submit warranty on completed fiberglass components in writing against defects of materials and<br />
workmanship and to meet the specified requirements of this Section for a period of one (1) year<br />
from delivery to site.<br />
1.04 HANDLING AND SHIPMENT<br />
A. Provide shipping crates of sufficient size and strength to protect components during shipping or<br />
ship fiberglass components in padded dedicated moving van.<br />
1. Provide additional protection as may be necessary to prevent soiling of surfaces and<br />
marring of finish.<br />
PART 2 - PRODUCTS<br />
2.01 ACCEPTABLE MANUFACTURES<br />
A. Subject to compliance with requirements, fiberglass manufacturer offering products that may be<br />
incorporated in work include:<br />
1. Architectural Reproductions; www.archrepro.com . Portland,<br />
OR, PH: 888-440-8007<br />
2. Approved equal.<br />
2.02 MATERIALS<br />
A. General: The fiberglass reinforced polyester plastic components shall be designed, fabricated<br />
and erected to conform to the state of <strong>Oregon</strong> Building Code, Local Codes and to the Architect’s<br />
design criteria.<br />
B. Glass cloth, matt and “Chop” shall be equal to the products of PPG-Owens Corning.<br />
C. The resin shall be flame retardant, promoted thixotropic polyester resin designed for use in<br />
hand laid up and spraying processes. The resin shall be specifically formulated for use in<br />
applications that require an ASTM E 84, Class I flame spread rating, without the use of fillers or<br />
antimony trioxide, with an ASTM E 84 flame spread rating of 25 unfilled smoke density of 380 or<br />
under.<br />
D. Gel Coat: The gel coat shall be a high-performance product with ultraviolet inhibitors as<br />
recommended by the gel coat and fiberglass panel manufacturer. Acceptable products are:<br />
1. IMC” by Cook Composites and Polymers Co., P. o. Box 419389, Kansas City, MO<br />
64141-6389, (816) 391-6000.<br />
2. Series by Neste Polyester Inc., 5106 Wheeler Avenue, Fort Smith, AK 72901, (501)<br />
646-7865<br />
3. Shield-NPG” by Ferro Corporation, One Erieview Plaza, Cleveland OH 44114, (216)<br />
641-8580<br />
4. Approved equal.<br />
E. Catalyzed Polyurethane: The catalyzed polyurethane shall be a high-performance product with<br />
ultraviolet inhibitors as recommended by the fiberglass panel manufacturer. Acceptable<br />
manufacturers are:<br />
1. Tnemec; www.tnemec.com <br />
2. Approved equal<br />
F. Fiberglass-reinforced polyester components shall be manufactured using the specified resins,<br />
reinforced with chopped glass fibers. All exposed surfaces shall be finished with custom<br />
colored gel-coat and catalyzed polyurethane.<br />
G. Internal metal reinforcement, anchorage clips, brackets and all other “built-in” accessories shall<br />
be captured and additionally reinforced with additional glass fiber and matt of sufficient<br />
thickness as required by the panel manufacturers design.<br />
H. All metal hardware, both loose and embedded, shall be stainless steel.<br />
I. Gel coat thickness shall be 0.015” minimum to 0.025” maximum.<br />
100% <strong>Addendum</strong> CONSTRUCTION B<br />
DOCUMENTS 06 6100<br />
April May 19, 24, 2013<br />
ARCHITECTURAL FIBERGLASS
UO Straub Hall - Deferred Maintenance and Seismic Upgrade 3 of 3<br />
J. Panel thickness shall be 3/16” minimum.<br />
2.03 PANEL FABRICATION<br />
A. Prior to commencement of work review the job site before selective demolition begins to<br />
determine the layout, masonry coursings and dimensions of the existing chimneys. Duplicate<br />
these layouts, masonry coursings and dimensions in so far as practical. Identify and resolve<br />
panel detail conflicts in advance and identify such condition and resolutions on the shop<br />
drawings.<br />
B. Carefully measure each existing chimney assembly component and replicate size, profile,<br />
position, and detail in the finished panel so far as practical. Indicate on shop drawings those<br />
indentations and/or detail which cannot be duplicated in the replication due to physical<br />
limitations of the manufacturing process.<br />
C. Full-size models and mock-ups shall be hand carved and machined as required to produce the<br />
replication patterns.<br />
D. Production molds shall be constructed from successive layers of glass fiber with tooling gel coat<br />
or alternately from rubber molds. Molds shall be constructed with sufficient thickness and<br />
rigidity to prevent deflection, warpage and defects during panel production.<br />
E. Provide all special transition piecesand special closures necessary for a complete, visually<br />
continuous, weather tight installation.<br />
F. Coordinate cutouts required for penetrations. Reinforce panel as required and provide special<br />
formed closures to make joints and intersection weather tight.<br />
PART 3 - EXECUTION<br />
3.01 INSTALLATION<br />
A. Coordinate required blocking for attachment of chimney reproductions to substructure. Provide<br />
additional, wood preservative treated or metal stud framing as may be required to attached and<br />
reinforce cornice panels for a solid installation.<br />
1. Coordinate installation with sheet metal flashing work.<br />
B. Erect reproduction chimneys plumb, square and true to line and level. Follow fiberglass<br />
reproduction manufacturer’s recommendations with regard to installation clearances, notches,<br />
and terminations.<br />
C. Install sealant and accessories as work progresses, so as to make the work weather tight.<br />
D. Prepare each chimney reproduction for installation by carefully sanding joints and shrinkages<br />
where blocking occurs to assure tight and flush fit.<br />
E. Fill joints with a continuous bead of sealant. Tooling finished joints to a slightly concave profile<br />
ensuring complete filling and flush installation.<br />
F. Carefully monitor ambient temperatures at time of panel installation and observe all panels to<br />
panel clearances recommended by the fiberglass manufacturer.<br />
G. Do not cut or abrade finishes, which cannot be completely restored in the field. Installer to<br />
make small inconspicuous repairs using manufactures color matching gel fill finish.<br />
H. Use only stainless steel connectors approved by the panel manufacturer. The installer shall<br />
supply these connectors.<br />
I. Countersink all exposed fasteners. Patch all attachment holes with gel fill finish supplied by the<br />
fiberglass panel manufacturer for field application. Finish attachment points so that there is no<br />
detectable difference in the completed panel surface.<br />
J. Clean installed panel to remove all dirt, smudges, and construction dirt. Use only those<br />
cleaning products and procedures recommended by the fiberglass manufacturer.<br />
END OF SECTION<br />
100% <strong>Addendum</strong> CONSTRUCTION B<br />
DOCUMENTS 06 6100<br />
April May 24, 19, 2013<br />
ARCHITECTURAL FIBERGLASS
UO Straub Hall - Deferred Maintenance and Seismic Upgrade 1 of 3<br />
PART 1 GENERAL<br />
1.01 SECTION INCLUDES<br />
SECTION 08 1116<br />
ALUMINUM DOORS AND FRAMES<br />
A. Aluminum door frames for doors specified elsewhere.<br />
B. Glazing.<br />
1.02 RELATED REQUIREMENTS<br />
A. Section 08 1433 – Stile and Rail Wood Doors: Glazed wood doors.<br />
B. Section 08 7100 - Door Hardware: Hardware for aluminum doors.<br />
C.. Section 08 8000 - Glazing: Glazing materials for aluminum doors and frames.<br />
1.03 REFERENCE STANDARDS<br />
A. AAMA 609 - Voluntary Guide Specification for Cleaning and Maintenance of Architectural<br />
Anodized Aluminum; American Architectural Manufacturers Association; 2009.<br />
B. AAMA 611 - Voluntary Specification for Anodized Architectural Aluminum; American<br />
Architectural Manufacturers Association; 2012.<br />
C. AAMA 701/702 - Voluntary Specifications for Pile Weatherstripping and Replaceable<br />
Fenestration Weatherseals; American Architectural Manufacturers Association; 2011.<br />
D. AAMA 2603 - Voluntary Specification, Performance Requirements and Test Procedures for<br />
Pigmented Organic Coatings on Aluminum Extrusions and Panels; American Architectural<br />
Manufacturers Association; 2002.<br />
E. ASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron<br />
and Steel Products; 2012.<br />
F. ASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate; 2010.<br />
G. ASTM B209M - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate<br />
[Metric]; 2010.<br />
H. ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods,<br />
Wire, Profiles, and Tubes; 2012.<br />
I. ASTM B221M - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods,<br />
Wire, Profiles, and Tubes [Metric]; 2012.<br />
1.04 SUBMITTALS<br />
A. See Section 01 3000 - Administrative Requirements, for submittal procedures.<br />
B. Shop Drawings: Include elevations of each opening type.<br />
1. Verify dimensions by field measurements before fabrication and indicate on shop<br />
drawings.<br />
C. Selection Samples: Complete set of color and finish options, using actual materials, for<br />
Architect's selection.<br />
D. Warranty: Submit manufacturer warranty and ensure that forms have been completed in<br />
Owner's name and registered with manufacturer.<br />
1.05 QUALITY ASSURANCE<br />
A. Manufacturer Qualifications: Not less than 5 years of experience in manufacturing components<br />
of the types specified.<br />
B. Installer Qualifications: Firm with documented experience in installing components of the types<br />
specified.<br />
<strong>Addendum</strong> B 08 1116<br />
May 24, 2013<br />
ALUMINUM DOORS AND FRAMES
UO Straub Hall - Deferred Maintenance and Seismic Upgrade 2 of 3<br />
1.06 DELIVERY, STORAGE, AND HANDLING<br />
A. Deliver aluminum components in manufacturer's standard protective packaging, palleted,<br />
crated, or banded together.<br />
B. Inspect delivered components for damage and replace. Repaired components will not be<br />
accepted.<br />
C. Store components under cover in manufacturer's packaging until installation.<br />
1.07 FIELD CONDITIONS<br />
A. Do not begin installation of interior aluminum components until space has been enclosed and<br />
ambient thermal conditions are being maintained at levels consistent with final project<br />
requirements.<br />
PART 2 PRODUCTS<br />
2.01 MANUFACTURERS<br />
A. Glazed Interior Aluminum Door Frames:<br />
1. Wilson Partitions: www.wilsonpart.com.<br />
2. Approved Equal.<br />
3. Substitutions: See Section 01 6000 - Product Requirements.<br />
2.02 DOORS AND FRAMES<br />
A. Door, Sidelight, and Transom Frames: Extruded aluminum hollow or C-shaped sections; no<br />
steel components.<br />
1. Finish: Pigmented coating, manufacturer's standard type.<br />
2. Weatherstripping: Replaceable pile type; at jambs and head.<br />
2.03 COMPONENTS<br />
A. Frames: Extruded aluminum shapes, not less than 0.062 inch thick, reinforced at hinge and<br />
strike locations.<br />
1. Corner Brackets: Extruded aluminum, fastened with stainless steel screws.<br />
2. Trim: Extruded aluminum, not less than 0.062 inch thick, removable snap-in type without<br />
exposed fasteners.<br />
2.04 MATERIALS<br />
A. Aluminum Sheet: ASTM B209 (ASTM B209M), alloy 5005-H14, stretcher leveled.<br />
B. Extruded Aluminum: ASTM B221 (ASTM B221M), alloy 6063-T5 or alloy 6463-T5.<br />
C. Natural Anodized Finish: Clear anodic coating; AAMA 611 AA-M12C22A31 Class II, minimum<br />
thickness 0.4 mil.<br />
D. Coated Finish: Pigmented organic coating of not less than 0.8 mils thickness, conforming to<br />
requirements of AAMA 2603; color as selected from manufacturer's full range by Architect.<br />
E. Aluminum Sheet: ASTM B209 (ASTM B209M), alloy 5005-H14, stretcher leveled.<br />
F. Extruded Aluminum: ASTM B221 (ASTM B221M), alloy 6063-T5 or alloy 6463-T5.<br />
G. Tubular Aluminum Doors: Provide 1-3/4 in thick glazed doors using materials as follows:<br />
H. Aluminum Door Frames: Provide frames sized to fit wall thicknesses indicated on the drawings,<br />
in profiles indicated, and constructed from materials as follows:<br />
I. Finish: High Performance Organic Coating: Kynar/Polyvinylidene Fluoride (PVDF) complying<br />
with requirements of AAMA 2604; color as selected from manufacturer's full range by Architect.<br />
2.05 ACCESSORIES<br />
A. Replaceable Weatherstripping: AAMA 701/702 wool pile.<br />
B. Fasteners: Aluminum, non-magnetic stainless steel, or other material warranted by<br />
manufacturer as non-corrosive and compatible with aluminum components.<br />
100% CONSTRUCTION DOCUMENTS 08 1116<br />
April 19, 2013<br />
ALUMINUM DOORS AND FRAMES
UO Straub Hall - Deferred Maintenance and Seismic Upgrade 3 of 3<br />
C. Brackets and Reinforcements: Manufacturer's high-strength aluminum units where feasible,<br />
otherwise, non-magnetic stainless steel or steel hot-dip galvanized in compliance with ASTM<br />
A123/A123M.<br />
D. Bituminous Coating: Cold-applied asphaltic mastic, compounded for 30-mil thickness per coat.<br />
PART 3 EXECUTION<br />
3.01 PREPARATION<br />
A. Perform cutting, fitting, forming, drilling, and grinding of frames as required for project<br />
conditions.<br />
B. Replace components with damage to exposed finishes.<br />
C. Separate dissimilar metals to prevent electrolytic action between metals.<br />
3.02 INSTALLATION<br />
A. Install doors and frames in accordance with manufacturer's instructions and approved shop<br />
drawings.<br />
B. Set frames plumb, square, level, and aligned to receive doors. Anchor frames to adjacent<br />
construction in strict accordance with manufacturer's recommendations and within specified<br />
tolerances.<br />
C. Where aluminum surfaces contact metals other than stainless steel, zinc, or small areas of<br />
white bronze, protect from direct contact by painting dissimilar metal with heavy coating of<br />
bituminous paint.<br />
D. Hang doors and adjust hardware to achieve specified clearances and proper door operation.<br />
E. Install door hardware as specified in Section 08 7100.<br />
3.03 CLEANING<br />
A. Upon completion of installation, thoroughly clean frame surfaces in accordance with AAMA<br />
609.<br />
B. Do not use abrasive, caustic, or acid cleaning agents.<br />
3.04 PROTECTION<br />
A. Protect products of this section from damage caused by subsequent construction until<br />
substantial completion.<br />
B. Replace damaged or defective components that cannot be repaired to a condition<br />
indistinguishable from undamaged components.<br />
END OF SECTION<br />
100% CONSTRUCTION DOCUMENTS 08 1116<br />
April 19, 2013<br />
ALUMINUM DOORS AND FRAMES
Door/Hardware Index<br />
No Area<br />
Door # HWSet #<br />
001-1 01<br />
001-1E 43<br />
001-2 02<br />
001-3 02<br />
001-4 02<br />
001-5 03<br />
001-6 08<br />
002-1 04<br />
003-1 05<br />
004-1 05<br />
004-2 04<br />
005-1 05<br />
006-1 04<br />
007-1 04<br />
008-1 04<br />
008-2 05<br />
009-1 04<br />
010-1 04<br />
011-1 04<br />
012-1 04<br />
013-1 04<br />
014-1 04<br />
015-1 04<br />
016-1 04<br />
017-1 04<br />
018-1 04<br />
020-1 02<br />
020-2 02<br />
020-3 05<br />
021-1 48<br />
021-2 06<br />
024-1 07<br />
024-2 08<br />
025-1 07<br />
026-1 09<br />
026-2 43<br />
026-3 43<br />
027-1 10<br />
027-2 43<br />
028-1 08<br />
Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />
2013 2:28PM EDT<br />
Supplier: Ingersoll Rand Security<br />
Technologies<br />
Revision #: 4 Rev Date: May 14 2013<br />
11:28AM EDT<br />
Page 1 of 10
Door # HWSet #<br />
031-1 11<br />
031-2<br />
031-3 12<br />
031-4 43<br />
031-5 11<br />
032-1 05<br />
033-1 02<br />
034-1 13<br />
035-1 14<br />
036-1 11<br />
037-1 04<br />
038-1 04<br />
038-2 04<br />
039-1 02<br />
040-1 05<br />
040-2 15<br />
040-3 16<br />
041-1 02<br />
042-1 05<br />
043-1 17<br />
044-1 05<br />
046-1 05<br />
048-1 05<br />
051-1 14<br />
051-2 05<br />
051-3 18<br />
051-4 04<br />
051-5 07<br />
070-1 06<br />
100-1 07<br />
101-1 05<br />
102-1 05<br />
103-1 11<br />
104-1 11<br />
105-1 11<br />
106-1 05<br />
107-1 11<br />
107-2 19<br />
108-1 05<br />
109-1 05<br />
110-1 11<br />
110-2 49<br />
110-3 41<br />
Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />
2013 2:28PM EDT<br />
Supplier: Ingersoll Rand Security<br />
Technologies<br />
Revision #: 4 Rev Date: May 14 2013<br />
11:28AM EDT<br />
Page 2 of 10
Door # HWSet #<br />
110-4 02<br />
111-1 05<br />
112-1 04<br />
112-2 50<br />
112-3 19<br />
115-1 22<br />
120-1 07<br />
120-2 20<br />
120-3 23<br />
121-1 24<br />
122-2 24<br />
122-3 27<br />
123-1 05<br />
124-1 09<br />
125-1 11<br />
126-1 26<br />
127-1 11<br />
128-1 11<br />
129-1 11<br />
130-1 42<br />
130-1S 29<br />
130-3 30<br />
130-4 31<br />
131-1 11<br />
131-2 20<br />
132-1 11<br />
133-1 11<br />
137-1 11<br />
138-1 23<br />
138-2 32<br />
139-1 11<br />
141-1 02<br />
142-1 04<br />
142-2 04<br />
142-3 04<br />
143-1 04<br />
143-2 04<br />
144-1 02<br />
145-1 04<br />
146-1 04<br />
146-2 04<br />
146-3 04<br />
146-4 02<br />
Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />
2013 2:28PM EDT<br />
Supplier: Ingersoll Rand Security<br />
Technologies<br />
Revision #: 4 Rev Date: May 14 2013<br />
11:28AM EDT<br />
Page 3 of 10
Door # HWSet #<br />
147-1 15<br />
149-1 02<br />
150-1 34<br />
150-2 35<br />
150-3 35<br />
150-4 02<br />
152-1 23<br />
152-2 23<br />
154-1 04<br />
154-2 04<br />
154-3 04<br />
154-4 04<br />
156-1 04<br />
156-2 04<br />
161-1 11<br />
161-2 14<br />
161-3 37<br />
162-1 17<br />
166-1 11<br />
167-1 14<br />
167-2 02<br />
168-1 14<br />
168-2 14<br />
168-3 14<br />
168-4 38<br />
168-5 25<br />
168-6 25<br />
170-1 39<br />
170-1S 29<br />
170-2 31<br />
170-3 32<br />
172-1 11<br />
172-2 44<br />
173-1 11<br />
174-1 28<br />
177-1 11<br />
178-1 26<br />
179-1 11<br />
179-2 14<br />
180-1 11<br />
180-2 27<br />
181-1 11<br />
182-1 09<br />
Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />
2013 2:28PM EDT<br />
Supplier: Ingersoll Rand Security<br />
Technologies<br />
Revision #: 4 Rev Date: May 14 2013<br />
11:28AM EDT<br />
Page 4 of 10
Door # HWSet #<br />
183-1 05<br />
184-1 40<br />
184-2 27<br />
186-1 24<br />
187-1 05<br />
187-2 05<br />
187-3 14<br />
188-1 24<br />
189-1 08<br />
189A-1 11<br />
190-1 11<br />
190-2 27<br />
190-3 50<br />
190-4 49<br />
190-5 37<br />
191-1 11<br />
192-1 11<br />
193-1 11<br />
194-1 11<br />
195-1 11<br />
196-1 11<br />
197-1 11<br />
198-1 18<br />
199-1 26<br />
201-1 18<br />
202-1 11<br />
202-2 01<br />
202-3 02<br />
203-1 11<br />
204-1 11<br />
205-1 11<br />
206-1 11<br />
207-1 11<br />
208-1 24<br />
209-1 11<br />
210-1 45<br />
210-2 11<br />
211-1 11<br />
220-1 11<br />
221-1 11<br />
222-1 11<br />
223-1 11<br />
224-1 10<br />
Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />
2013 2:28PM EDT<br />
Supplier: Ingersoll Rand Security<br />
Technologies<br />
Revision #: 4 Rev Date: May 14 2013<br />
11:28AM EDT<br />
Page 5 of 10
Door # HWSet #<br />
225-1 11<br />
226-1~ 26<br />
227-1 11<br />
228-1 26<br />
229-1 11<br />
230-1 42<br />
230-2 27<br />
230-3 06<br />
231-1 11<br />
232-1 11<br />
233-1 11<br />
234-1 11<br />
235-1 11<br />
236-1 02<br />
237-1 11<br />
239-1 11<br />
250-1 11<br />
251-1 11<br />
251-2 11<br />
252-1 11<br />
253-1 11<br />
255-1 11<br />
266-1 11<br />
267-1 11<br />
267-2 27<br />
269-1 11<br />
270-1 26<br />
270-2 06<br />
271-1 11<br />
273-1 11<br />
274-1 26<br />
275-1 11<br />
276-1 09<br />
277-1 11<br />
277-2 27<br />
278-1 11<br />
279-1 11<br />
280-1 11<br />
280-2 01<br />
280-3 27<br />
281-1 11<br />
282-1 11<br />
283-1 11<br />
Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />
2013 2:28PM EDT<br />
Supplier: Ingersoll Rand Security<br />
Technologies<br />
Revision #: 4 Rev Date: May 14 2013<br />
11:28AM EDT<br />
Page 6 of 10
Door # HWSet #<br />
286-1 11<br />
287-1 11<br />
288-1 11<br />
289-1 11<br />
290-1 44<br />
290-2 45<br />
291-1 11<br />
292-1 24<br />
294-1 18<br />
295-1 11<br />
297-1 26<br />
299-1 11<br />
301-1 18<br />
302-1 11<br />
302-2 01<br />
303-1 11<br />
304-1 11<br />
305-1 11<br />
306-1 11<br />
307-1 11<br />
308-1 11<br />
309-1 11<br />
310-1 45<br />
320-1 11<br />
321-1 11<br />
322-1 46<br />
323-1 11<br />
324-1 09<br />
325-1 11<br />
326-1 26<br />
327-1 11<br />
328-1 26<br />
329-1 11<br />
330-1 42<br />
330-2 27<br />
330-3 06<br />
331-1 11<br />
332-1 11<br />
334-1 11<br />
334-2 27<br />
335-1 11<br />
337-1 11<br />
338-1 11<br />
Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />
2013 2:28PM EDT<br />
Supplier: Ingersoll Rand Security<br />
Technologies<br />
Revision #: 4 Rev Date: May 14 2013<br />
11:28AM EDT<br />
Page 7 of 10
Door # HWSet #<br />
339-1 11<br />
340-1 11<br />
341-1 11<br />
343-1 13<br />
350-1 11<br />
351-1 11<br />
352-1 11<br />
353-1 11<br />
354-1 11<br />
354-2 27<br />
355-1 11<br />
356-1 11<br />
366-1 11<br />
367-1 11<br />
368-1 11<br />
368-2 27<br />
369-1 11<br />
370-1 26<br />
370-2 06<br />
371-1 11<br />
373-1 11<br />
374-1 26<br />
375-1 11<br />
376-1 09<br />
377-1 11<br />
378-1 46<br />
379-1 11<br />
380-1 11<br />
381-1 11<br />
382-1 11<br />
385-1 11<br />
386-1 13<br />
387-1 11<br />
389-1 11<br />
390-1 45<br />
392-1 24<br />
394-1 11<br />
395-1 11<br />
395-2 11<br />
395-3 29<br />
397-1 11<br />
399-1 11<br />
399-2 21<br />
Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />
2013 2:28PM EDT<br />
Supplier: Ingersoll Rand Security<br />
Technologies<br />
Revision #: 4 Rev Date: May 14 2013<br />
11:28AM EDT<br />
Page 8 of 10
Door # HWSet #<br />
401-1 18<br />
402-1 11<br />
402-2 15<br />
403-1 11<br />
404-1 11<br />
405-1 11<br />
406-1 24<br />
407-1 11<br />
409-1 13<br />
409-2 18<br />
409-3 11<br />
409-4 47<br />
409-5 11<br />
410-1 45<br />
420-1 11<br />
421-1 11<br />
422-1 11<br />
423-1 11<br />
424-1 10<br />
425-1 11<br />
426-1 26<br />
427-1 11<br />
428-1 26<br />
429-1 11<br />
430-1 42<br />
430-2 27<br />
430-3 06<br />
431-1 11<br />
432-1 11<br />
433-1 11<br />
434-1 11<br />
434-2 27<br />
435-1 11<br />
437-1 11<br />
438-1 11<br />
439-1 11<br />
440-1 11<br />
441-1 11<br />
443-1 13<br />
450-1 11<br />
451-1 11<br />
452-1 11<br />
453-1 11<br />
Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />
2013 2:28PM EDT<br />
Supplier: Ingersoll Rand Security<br />
Technologies<br />
Revision #: 4 Rev Date: May 14 2013<br />
11:28AM EDT<br />
Page 9 of 10
Door # HWSet #<br />
454-1 11<br />
454-2 27<br />
455-1 11<br />
456-1 11<br />
457-1 11<br />
466-1 11<br />
466-2 27<br />
467-1 11<br />
469-1 11<br />
470-1 26<br />
470-2 06<br />
471-1 11<br />
473-1 11<br />
474-1 26<br />
475-1 11<br />
476-1 09<br />
476-2 28<br />
477-1 11<br />
478-1 11<br />
479-1 11<br />
480-1 11<br />
481-1 11<br />
483-1 11<br />
484-1 11<br />
484-2 11<br />
484-3 27<br />
490-1 45<br />
491-1 11<br />
493-1 11<br />
494-1 11<br />
495-1 11<br />
497-1 11<br />
RT-1 29<br />
RT-2 33<br />
RT-2 33<br />
Project: UO Straub Hall (Renovation) Control #: 28804 Print Date: May 14<br />
2013 2:28PM EDT<br />
Supplier: Ingersoll Rand Security<br />
Technologies<br />
Revision #: 4 Rev Date: May 14 2013<br />
11:28AM EDT<br />
Page 10 of 10