BY s c h ü t z .<br />

H e a t i n g – v e n t i n g – c o o l i n g<br />

i n a s i n g l e s y s t e m .


y S C H Ü T Z .<br />

P ro v e n t e c h n o l o g y f o r a b a l a n c e d ro o m<br />

e n v i ro n m e n t .<br />

air conomy ® by SCHÜTZ is the perfect solution for everyone who<br />

appreciates that little extra cosy comfort at home or in the office.<br />

Heating, venting, cooling – with air conomy ® you offer your<br />

customers a "multifunctional" <strong>system</strong> that lets them breathe easy<br />

no matter what the season.<br />

2


heats.<br />

Cosy warmth in living and work areas thanks to our proven floor<br />

heating <strong>system</strong>: air conomy ® ensures pleasant and gently radiant heat<br />

across the entire floor – always in an optimal temperature range in<br />

terms of thermal physics.<br />

vents.<br />

Fresh air at the right temperature in all rooms: The air conomy ® <strong>system</strong><br />

plate guarantees optimal air distribution in the rooms people spend time in.<br />

Depending on what is required, heated or cooled air flows into the room<br />

before the façade - air outlets allow for a draught-free and inconspicuous<br />

air supply. Used air is taken to heat recovery via an exhaust air-<strong>system</strong> to<br />

pre-heat the next flow of fresh air.<br />

cools.<br />

Cooling when temperatures are too high in summer: When needed,<br />

air conomy ® sends cold water through the pipe register in the floor.<br />

Following the principle of still cooling, heat (e.g. from the sun’s rays)<br />

is extracted via the floor.<br />

– hygienically safe.<br />

air conomy ® meets exacting requirements in the home or work environment<br />

thanks to its multifunctional capability. Polluted room air and odours are<br />

continuously ventilated. Filtered fresh air prevents damage to the building<br />

caused by excessive moisture and mildew.<br />

Reference buildings: www.schuetz.net<br />

3


4<br />

b y S C H Ü T Z .<br />

Q u a l i t y o f l i f e y o u c a n f e e l .


provides the optimal solution for:<br />

z One-family and multi-family houses<br />

z Conservatories<br />

z Schools, nursery schools<br />

z Office and administrative buildings<br />

z Showrooms and assembly rooms<br />

Room design "as you like it".<br />

The harmonised <strong>system</strong> components allow a totally free hand<br />

to design rooms in accordance with individual requirements.<br />

The whole duct <strong>system</strong> is laid in the insulation and is no longer<br />

visible once the screed is in place.<br />

Save energy.<br />

The advanced <strong>system</strong> technology ensures a particularly energy-saving<br />

mode of operation. Efficient use of thermal energy is achieved through<br />

heat recovery from exhaust air and low inlet temperatures.<br />

Controlled living space ventilation in combination with the low temperature<br />

principle: air conomy ® offers exactly what an energy efficient building<br />

demands.<br />

Reference buildings: www.schuetz.net<br />

5


y S C H Ü T Z .<br />

T h e i n t e l l i g e n t s y s t e m w i t h l o a d s<br />

o f b e n e f i t s .<br />

ensures<br />

optimal distribution<br />

of fresh air without<br />

extensive piping.<br />

The whole air<br />

conduction <strong>system</strong><br />

is laid in the<br />

insulation and is no<br />

longer visible once<br />

the screed is in place.<br />

The<br />

<strong>system</strong> locates the<br />

heating pipes on<br />

the top and guides<br />

the air underneath.<br />

combines many benefits in one intelligent <strong>system</strong>.<br />

z Unlimited scope for design of rooms<br />

z Heating – venting – cooling in one <strong>system</strong><br />

z Improved standard of accommodation thanks to an ideal room climate<br />

z Heating in winter, cooling in summer<br />

z Draught-free exchange of air<br />

z Comfortable heating behaviour<br />

z Energy saving operation<br />

z Exploitation of low temperatures<br />

z Heat recovery<br />

z Highly reliable operation<br />

z Planning certainty<br />

z Easy installation and operation<br />

6<br />

z Plug-in <strong>system</strong> components (ventilation equipment etc.)<br />

z Proven <strong>system</strong> technology


y S C H Ü T Z .<br />

M o d u l a r t e c h n o l o g y m a k e s i n s t a l l a t i o n e a s i e r.<br />

The well thought out floor construction<br />

allows for clearly laid out and easy<br />

installation.<br />

z Sealed joint laying of the thermal and impact<br />

sound insulation with the edge insulation strip<br />

on the bare floor<br />

z Laying of the floor ducts from the ascending<br />

pipe into the individual rooms<br />

z Allocation of the air outlets and laying of the<br />

<strong>system</strong> elements<br />

z Easy placing of the heating pipe on the <strong>system</strong><br />

elements and connection to the manifold<br />

7


y S C H Ü T Z .<br />

T h e f l o o r c o n s t r u c t i o n .<br />

All materials also used for underfloor heating<br />

are suitable as a floor covering for :<br />

Carpet, tiles, parquet, stone floor and laminate.<br />

The illustrations show various floor constructions<br />

in detail.<br />

65<br />

Floor construction for<br />

evenly heated rooms<br />

10<br />

6<br />

4 5<br />

2<br />

1<br />

3<br />

8<br />

9<br />

7<br />

20<br />

30<br />

23<br />

138<br />

1 Thermal and impact sound<br />

insulation EPS-T 040 Type 25-2<br />

2 Thermal insulation EPS 040<br />

DE0 30 mm<br />

3 Floor duct<br />

4 Outlet module<br />

5 aircon-floor<br />

6 System element aircon 20<br />

7 aircon-takk<br />

8 Floor duct guard band<br />

9 Heating screed<br />

10 Frame with grill inset<br />

65<br />

Floor construction for<br />

outside air below<br />

10<br />

6<br />

4 5<br />

2<br />

1<br />

3<br />

8<br />

9<br />

7<br />

20<br />

30<br />

32<br />

147<br />

1 Supplementary thermal<br />

insulation PUR E 32 ac<br />

2 Thermal insulation EPS 040<br />

DE0 30 mm<br />

3 Floor duct<br />

4 Outlet module<br />

5 aircon-takk<br />

6 System element aircon 20<br />

7 aircon-takk<br />

8 Floor duct guard band<br />

9 Heating screed<br />

10 Frame with grill inset<br />

8


y S C H Ü T Z .<br />

Ve n t i l a t i o n e q u i p m e n t a n d<br />

re g u l a t i o n .<br />

Optimal control and regulation of<br />

requires suitable<br />

ventilation equipment and simple control units.<br />

SCHÜTZ offers proven advanced technology that ensures safe,<br />

convenient and energy saving operation of the<br />

<strong>system</strong>.<br />

Heating / venting: with the heat recovery appliance WRG aircon 300<br />

z Up to 90% heat recovery<br />

z Max. air quantity 270 m 3 / h<br />

z Remote control: 3 stage switch with on/off function<br />

z Fully automatic bypass<br />

z Easy installation<br />

z Ventilators with energy saving direct current motors<br />

z Condensate removal<br />

z Easy maintenance<br />

Heating / venting / cooling: with the central ventilation appliance aircon 500<br />

z Up to 84% heat recovery<br />

z Max. air quantity 500 m 3 / h<br />

z Programmable weekly operation program<br />

z Setting via remote control<br />

z Control via control unit<br />

z Easy maintenance through flaps that can be opened<br />

z Condensate removal<br />

z EIB connection possible<br />

9


y S C H Ü T Z .<br />

P l a n n i n g c e r t a i n t y a n d s e r v i c e i n c l u d e d .<br />

Proven <strong>system</strong> technology from one source: SCHÜTZ offers its customers an<br />

individual project planning service – from providing a quote through to detailed<br />

<strong>system</strong> planning. When a coordinated approach is followed,<br />

can also be expanded in phases for the individual functions<br />

of heating, venting and cooling.<br />

SCHÜTZ planning certainty:<br />

z Initial budget quotation<br />

z Project-specific quote<br />

z System and integration planning:<br />

w Heating load calculation<br />

w Heating surface dimensioning<br />

w Air quantity calculation<br />

w Duct network calculation<br />

w Mass flow calculation<br />

w Drawing, incl. duct network and floor constructions<br />

w Mass assembly<br />

w Drawing of ventilation appliance with dimensions<br />

SCHÜTZ Service:<br />

z Reliable partner for "heating – venting –<br />

air conditioning" installation contractors<br />

z Direct sales to contractors<br />

z Complete <strong>system</strong> supply<br />

z Direct delivery to building sites<br />

z System training on location<br />

z Guarantee and warranty<br />

z Support for in-house exhibitions and sales talks<br />

z Training measures<br />

Reference buildings: www.schuetz.net<br />

10


y S C H Ü T Z .<br />

I n n o v a t i v e H VA C R * o ff e r s<br />

t o t a l l y n e w p e r s p e c t i v e s .<br />

Solar collector<br />

Even with little sunshine<br />

the heat can be utilised<br />

Earth heat exchanger<br />

In winter: Pre-heating of<br />

cold outside air in the ground,<br />

heat transfer from exhaust air<br />

in living space, post-heating in<br />

air conomy ® floor.<br />

In summer: Cooling of outside<br />

air in the ground, re-cooling in<br />

central ventilation appliance,<br />

post-cooling in air conomy ® floor.<br />

Heat pump with earth collector<br />

Greater heat pump efficiency at<br />

air conomy ® temperature level.<br />

Heat storage<br />

Low temperature level means:<br />

less heat loss, buffer stores heat,<br />

producer switches less often.<br />

with air conomy ® .<br />

11<br />

Our engineers are always looking for innovative, even<br />

more effective HVACR* solutions. Current developments<br />

offer architects, home owners and contractors totally new<br />

perspectives. From solar collectors through geothermal<br />

heat exchangers to heat pumps – with<br />

you‘ll achieve maximum efficiencies!<br />

* Heating, ventilation, air conditioning and refrigeration


01.07 / 5.000 / bsd / Corzilius<br />

(Technical details subject to change)<br />

SCHÜTZ TANK IN TANK<br />

Plastic – twice as safe,<br />

twice as good<br />

z Double walled<br />

construction for modern,<br />

safe heating oil storage<br />

z Dimensions to meet<br />

requirements<br />

z Flexible capacity<br />

z SMP barrier against<br />

heating oil odour<br />

SCHÜTZ AQUA BLOCK<br />

Rainwater <strong>system</strong>s –<br />

easy on the environment,<br />

lowers costs<br />

z The progressive tank<br />

<strong>system</strong> for sensible<br />

use of rainwater<br />

z Saves costs and is easy<br />

on the environment<br />

z Available for installation<br />

in the cellar or the<br />

ground<br />

SCHÜTZ SURFACE<br />

HEATING SYSTEMS –<br />

Practical and economical<br />

z All key floor heating<br />

components in own<br />

production<br />

z Harmonised <strong>system</strong><br />

components<br />

z Made in Germany<br />

z Absolutely reliable<br />

delivery times<br />

SCHÜTZ Energietechnik GmbH & Co. KG<br />

Schützstrasse 12<br />

D-56242 Selters<br />

Germany<br />

Phone +49 (0) 26 26 / 77-12 10<br />

Fax +49 (0) 26 26 / 77- 4 40<br />

E-Mail airconomy@schuetz.net<br />

www.schuetz.net

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!