March 2006<strong>Pressure</strong> <strong>Relief</strong> <strong>Flaps</strong>Actionair<strong>Pressure</strong><strong>Relief</strong> <strong>Flaps</strong>Models D-PRF and G-PRFFeatures● All aluminium construction● Duct mounting pressurerelief flap● Wall mounting pressurerelief flapwww.actionair.co.uk


<strong>Pressure</strong> <strong>Relief</strong> <strong>Flaps</strong>IntroductionModel D-PRFDuct Mounting <strong>Pressure</strong> <strong>Relief</strong> FlapA functional range of aluminiumdampers available from Actionair, theModel D-PRF duct mounting pressurerelief flap and the Model G-PRF wallmounting pressure relief flap.The Model D-PRF incorporates a ductmounting flanged frame for eithervertical or horizontal mounting and issuitable for low velocity, low pressuresystems.Model G-PRF is designed with a grillestyle flange for vertical mounting onlyand is suitable for low velocity, lowpressure applications.Each damper is constructed fromaluminium extrusions and aluminiumsections with nylon bushes andneoprene seals fitted to the pressurerelief flaps.Both models of pressure relief flaps mayhave additional weights fitted to theblades whilst the Model D-PRF is alsoavailable with linked blades to provide auniform operation.DescriptionModel D-PRF is suitable for use in lowpressure, low velocity applications andmay be mounted vertically or horizontally.Blades are fitted with free running nylonbushes to operate at minimum pressure.Each blade is also fitted with neopreneedge seals, for uniform operation theblades can be linked, also adjustableblade weights can be added. A matchingtwin frame may also be provided toensure the blades are not obstructed andopen within the extended casing.Minimum size is 150mm x 150mm andmaximum single section is 2000mm x2000mm. Note: a mullion is fitted forsizes over 1000mm. Multiple assembliesare available.Blade ArrangementMechanical stops prevent blades fromfully opening to 90 degrees.Blade ArrangementOptional WeightsDimensions and Airflow Direction* Overall Size = Duct Size + 80mm65 Max1004040DuctSizeDuct SizeAirflowReversible AirflowPerformance GuideDuct Velocity m/s 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0<strong>Pressure</strong> (Pa) 7 12 17 21 24 28 32 372


<strong>Pressure</strong> <strong>Relief</strong> <strong>Flaps</strong>Model G-PRFWall Mounting <strong>Pressure</strong> <strong>Relief</strong> FlapDescriptionModel G-PRF is suitable for use in lowpressure, low velocity applicationsalthough only for vertical mounting. Bladesare fitted with free running nylon bushes tooperate at minimum pressure. Each bladeis also fitted with neoprene edge seals. Amatching flange and adjustable bladeweights are available on request.Minimum size is 100mm x 100mm andmaximum single section is 1800mm x1200mm. Note: a mullion is fitted after650mm and 1200mm in width.Blade ArrangementOptional WeightsDimensions and Airflow Direction* Overall Size = Duct Size + 45mm 95 Max5110 Max25DuctSize–19AirflowDuctSize25No. 8 Countersunk Screw fixing holes32Airflow OutAirflow InPerformance GuideDuct Velocity m/s 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0<strong>Pressure</strong> (Pa) 7 12 17 21 24 28 32 373


<strong>Pressure</strong> <strong>Relief</strong> <strong>Flaps</strong>www.actionair.co.ukStandard Ordering ProcedurePlease SpecifyModel D-PRFExampleFlange Style Model Type Fixing Operation Finish ControlF40 D-PRF F0 O 0 OF40 – 40mmFlanged Frame*If overall dimensions are critical, these must be stated on order.Model G-PRFExampleD-PRF – DuctAir <strong>Pressure</strong><strong>Relief</strong> FlapF0 – No Fixing.StandardF1 – CountersunkScrew Holes inFlange. NonstandardO – Airflow OUTTF – Extra Twin Frame(For Blade Fully OpenOperation, withinCasing)Please state separately onorder if required.0 – Mill FinishAluminium Bladesand FrameO – Standard (PlainBlades)W – WeightedBladesL – Linked BladesW/L – Weighted &Linked BladesFlange Style Model Type Fixing Operation Finish Control25C G-PRF F1 I 0 O25C – 25mm GrilleFlange (StandardModel G-PRF)G-PRF –Grille Air<strong>Pressure</strong><strong>Relief</strong> FlapF1 – Screw Holes inFlange. StandardO – Airflow OUTI – Airflow INPlease specifyairflow directionwhen ordering0 – Mill FinishAluminiumBlades andFrame. StandardO – Plain Blades.StandardW – WeightedBlades*If overall dimensions are critical, these must be stated on order.For further application, technical and pricing information,please refer to Actionair Sales Office.Actionair, South Street, Whitstable, Kent CT5 3DU England.T: (01227) 276100 F: (01227) 264262 Int: Code: +441227E: sales@actionair.co.uk W: www.actionair.co.ukPart of Ruskin Air Management Limitedno compromise...Ruskin Air Management LimitedPRODUCED BY GRAPHIC PARTNERSHIP 01227 457292 : Product Data Sheet Part Number LNNN 00.