Saturn I Countdown Manual Volume II, SA-7 (small).pdf - Heroicrelics
Saturn I Countdown Manual Volume II, SA-7 (small).pdf - Heroicrelics
Saturn I Countdown Manual Volume II, SA-7 (small).pdf - Heroicrelics
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
EMERGENCY PROCE[.\JRE 0 - 0" TO T+O")<br />
AUTOMATIC CUTOFF<br />
1. C1 FR: OeSERVE AUTOMAT IC CUTOFF<br />
13. CINP , CUNP: <strong>SA</strong>FETY SW ITCH AR MING OFF<br />
2 . CIFP: ALL PREVALVE SW I TCHES TO OFF POSITION<br />
3. CIFP: VERIFY DEL UGE PURGE 00 - IF NO T ON ,<br />
OPERATE DELUGE PURGE TO MANUAL<br />
4. RWC P : OPERATE WATER CuNTROL SYSTEM AS REQUIRED<br />
14 . RBHM : VE R IFY S-I FUEL AND Lox TAN KS<br />
VEN TED TO ZERO PS I<br />
15 . RPLC:<br />
VER IFY S - IV LHz AND Lo x TAN KS<br />
VEN TED TO ZERO PSI<br />
5. C IMP :<br />
16. C ILS : LAUNCH SEQUENCER ARM OFF<br />
RECORDER TRANSFER SWITCH TO EMERGENC Y<br />
POSIT I ON 17. NQIE.: THE PREVALVES MAY REMAIN CLOSED<br />
FOR 10 MINUTES DUR ING WH I CH THE<br />
6. RVFC : HYDRAUL IC PUMPS 1, 2, 3 AND 4 OFF<br />
Lox TAN KS MUST BE PRESSUR IZED ,<br />
7. CINP: FUNCT ION SELECTOR TO PRELA UNCH<br />
PREVALVES OPENED AND Lox BUBBL ING<br />
IN IT IATED. THE Lox TAN KS SHO ULD<br />
THEN BE VENTED AND BUBBL ING D IS<br />
8. CINP : VERIFY PREVALVE SW IT CHES OFF THEN<br />
RE SET CUTOFF<br />
CONT I NUE D WHEN THE PUMP INLE T<br />
TE MPERATURES REACH _275° F .<br />
9. C I FP; GG Lox I NJECTO R PURGE TO MANUAL<br />
1 0 . CI FP: Lox DOME PU RG E TO MAN UAL<br />
11 . RSEQ : SEQUENCE RECORDE RS TO SLOW SPEED<br />
1 2 . C lOP , C4DP: <strong>SA</strong>FE DESTRUCT<br />
rl<br />
,<br />
'" '" ct<br />
18 . NOTE: UPON EXCEED I NG 1 0 MINU TES THE PRE <br />
VALVES MUST RE MA IN CLOSED , Lox<br />
DRAINED AND STANDBY OBSERVED UNTI L<br />
AL L SUCTION L I NE FROST IS MEL TED .<br />
TH E PUMP INLET PR ESSURES MUST BE<br />
MON ITORED DURING THIS PER IOD AND IF<br />
TH E PRE SSURE EXCEEDS 200 PS IG (FULL<br />
CHART SCA LE) TH E PREVALVES MUST BE<br />
OP ENED .<br />
19 · CNTS: SECURE ALL OTHE R EQUIPMENT AS REQUI RED .