EMERGENCY PROCE[.\JRE 0 - 0" TO T+O")<br />

AUTOMATIC CUTOFF<br />

1. C1 FR: OeSERVE AUTOMAT IC CUTOFF<br />

13. CINP , CUNP: <strong>SA</strong>FETY SW ITCH AR MING OFF<br />

2 . CIFP: ALL PREVALVE SW I TCHES TO OFF POSITION<br />

3. CIFP: VERIFY DEL UGE PURGE 00 - IF NO T ON ,<br />

OPERATE DELUGE PURGE TO MANUAL<br />

4. RWC P : OPERATE WATER CuNTROL SYSTEM AS REQUIRED<br />

14 . RBHM : VE R IFY S-I FUEL AND Lox TAN KS<br />

VEN TED TO ZERO PS I<br />

15 . RPLC:<br />

VER IFY S - IV LHz AND Lo x TAN KS<br />

VEN TED TO ZERO PSI<br />

5. C IMP :<br />

16. C ILS : LAUNCH SEQUENCER ARM OFF<br />

RECORDER TRANSFER SWITCH TO EMERGENC Y<br />

POSIT I ON 17. NQIE.: THE PREVALVES MAY REMAIN CLOSED<br />

FOR 10 MINUTES DUR ING WH I CH THE<br />

6. RVFC : HYDRAUL IC PUMPS 1, 2, 3 AND 4 OFF<br />

Lox TAN KS MUST BE PRESSUR IZED ,<br />

7. CINP: FUNCT ION SELECTOR TO PRELA UNCH<br />

PREVALVES OPENED AND Lox BUBBL ING<br />

IN IT IATED. THE Lox TAN KS SHO ULD<br />

THEN BE VENTED AND BUBBL ING D IS­<br />

8. CINP : VERIFY PREVALVE SW IT CHES OFF THEN<br />

RE SET CUTOFF<br />

CONT I NUE D WHEN THE PUMP INLE T<br />

TE MPERATURES REACH _275° F .<br />

9. C I FP; GG Lox I NJECTO R PURGE TO MANUAL<br />

1 0 . CI FP: Lox DOME PU RG E TO MAN UAL<br />

11 . RSEQ : SEQUENCE RECORDE RS TO SLOW SPEED<br />

1 2 . C lOP , C4DP: <strong>SA</strong>FE DESTRUCT<br />

rl<br />

,<br />

'" '" ct<br />

18 . NOTE: UPON EXCEED I NG 1 0 MINU TES THE PRE ­<br />

VALVES MUST RE MA IN CLOSED , Lox<br />

DRAINED AND STANDBY OBSERVED UNTI L<br />

AL L SUCTION L I NE FROST IS MEL TED .<br />

TH E PUMP INLET PR ESSURES MUST BE<br />

MON ITORED DURING THIS PER IOD AND IF<br />

TH E PRE SSURE EXCEEDS 200 PS IG (FULL<br />

CHART SCA LE) TH E PREVALVES MUST BE<br />

OP ENED .<br />

19 · CNTS: SECURE ALL OTHE R EQUIPMENT AS REQUI RED .