PYX5,9<br />

Parameter sheet for PYX<br />

Lock<br />

level<br />

All<br />

locked<br />

Only<br />

SV<br />

End<br />

User<br />

Set<br />

Maker<br />

Lock<br />

level<br />

All<br />

locked<br />

Only<br />

SV<br />

End<br />

User<br />

Set<br />

Maker<br />

0 1 2 3<br />

0 1 2 3<br />

Mean of parameters Range Unit<br />

Display<br />

Display<br />

Mean of parameters Range Unit<br />

####<br />

Measured value (PV) 0~100%<br />

Engineering<br />

unit<br />

A11H<br />

Hysteressis for Alarm 11 0~100%<br />

Engineering<br />

unit<br />

####<br />

Setting value (SV) 0~100%<br />

Engineering<br />

unit<br />

AL12 Set value for Alarm 12 0~100%<br />

Engineering<br />

unit<br />

####<br />

Manual manipulated variable<br />

(MV)<br />

–3~103%<br />

%<br />

A12H Hysteressis for Alarm 12 0~100%<br />

Engineering<br />

unit<br />

LOCK Lock for other parameters 0~3<br />

AT<br />

STAT<br />

TIME<br />

PROG<br />

TM1R<br />

TM1S<br />

D-SV<br />

CAS<br />

Remote SV input value<br />

OUT 1 MV for output 1<br />

MOD Mode of control AUTO<br />

MAN<br />

Auto tuning command<br />

Ramp / Soak location<br />

Ramp / Soak rest time<br />

Ramp / Soak command<br />

0~100%<br />

REM<br />

OFF<br />

ON<br />

LOW<br />

Second SV 0~100%<br />

OFF<br />

1-RP<br />

1-SK<br />

2-RP<br />

2-SK<br />

3-RP LOOP Time for Loop break detection 0.0~99.59 MM. ss<br />

3-SK<br />

4-RP<br />

4-SK<br />

END<br />

OFF<br />

RUN<br />

HOLD<br />

(END)<br />

SV1 1st. target point (SV) 0~100%<br />

TM2R<br />

TM2S<br />

Time of 1st. Ramp segment 0.0~99.59<br />

Time of 1st. Soak segment 0.0~99.59<br />

SV2 2nd. target point (SV) 0~100%<br />

SV3<br />

TM3R<br />

TM3S<br />

TM4R<br />

TM4S<br />

P-ON<br />

Time of 2nd. Ramp segment 0.0~99.59<br />

Time of 2nd. Soak segment 0.0~99.59<br />

3rd. target point (SV) 0~100%<br />

Time of 3rd. Ramp segment 0.0~99.59<br />

Time of 3rd. Soak segment 0.0~99.59<br />

SV4 4th. target point (SV) 0~100%<br />

P<br />

HYS<br />

I<br />

D<br />

OUT 2<br />

DB<br />

AR<br />

MAN<br />

–3~103%<br />

MV for output 2 –3~103% %<br />

0.0~99.59/<br />

100h<br />

Time of 4th. Ramp segment 0.0~99.59<br />

Time of 4th. Soak segment 0.0~99.59<br />

Auto start demand when turn on NO<br />

for Ramp/Soak<br />

YES<br />

Proportional Band<br />

0.0~999.9<br />

Hysteresis for two step control 0~100%<br />

Reset time<br />

Rate time<br />

Dead Band/ Overlap<br />

0~3200<br />

0~999.9<br />

COOL<br />

Rate of Proportional Band<br />

0.0~10.0<br />

for cooling<br />

–50~50%<br />

Anti-Reset Wind-up 0~100%<br />

Manual Reset value<br />

–100.0~<br />

%<br />

100.0<br />

AL1T Alarm actions for Alarm 1<br />

0000~(*1)<br />

3FFFh<br />

Engineering<br />

unit<br />

%<br />

Engineering<br />

unit<br />

HH. mm<br />

Engineering<br />

unit<br />

HH. mm<br />

HH. mm<br />

Engineering<br />

unit<br />

HH. mm<br />

HH. mm<br />

Engineering<br />

unit<br />

HH. mm<br />

HH. mm<br />

Engineering<br />

unit<br />

HH. mm<br />

HH. mm<br />

%<br />

Engineering<br />

unit<br />

Second<br />

Second<br />

%<br />

Engineering<br />

unit<br />

AL13 Set value for Alarm 13 0~100%<br />

AL2T Alarm actions for Alarm 2<br />

AL21 Set value for Alarm 21<br />

HB-A<br />

CT<br />

CTRL<br />

STNO<br />

A13H Hysteressis for Alarm 13 0~100%<br />

PVT<br />

PVF<br />

PVB<br />

SFT<br />

Curent setting for Heater break<br />

detection<br />

Input type/Decimal point/Temp.<br />

Unit<br />

Upper scale for PV<br />

Lower scale for PV<br />

PV offset<br />

Kind of control<br />

0000~(*1)<br />

3FFFh<br />

0~100%<br />

A21H Hysteressis for Alarm 21 0~100%<br />

AL22 Set value for Alarm 22 0~100%<br />

A22H Hysteressis for Alarm 22 0~100%<br />

AL23 Set value for Alarm 23 0~100%<br />

A23H Hysteressis for Alarm 23 0~100%<br />

PVD<br />

TF<br />

DT<br />

REV-1<br />

Heater Curent indicated value<br />

Decimal point position<br />

Rate of Digital Filter<br />

Cycle of computing<br />

Not es : *(1) : Hexa decimal code : refer to "Kinds of alarm" (page 4).<br />

(2) : Hexa decimal code : refer to "Input range" (page 2).<br />

1~50<br />

0~50<br />

0000~<br />

4111h (*2)<br />

–1999~<br />

9999<br />

–1999~<br />

9999<br />

0~2<br />

0.0~900.0<br />

–50~50%<br />

SV-H High limit setting of SV 0~100%<br />

SV-L Low limit setting of SV 0~100%<br />

REMF Upper scale of Remote SV 0~100%<br />

REMB Lower scale of Remote SV 0~100%<br />

REV-2<br />

TC-1<br />

TC-2<br />

Control action for output 1<br />

(Direct of reverse)<br />

Control action for output 2<br />

(Direct of reverse)<br />

Proportional Cycle for output 1<br />

Proportional Cycle for output 2<br />

FUZY<br />

PID<br />

0.5<br />

1~120<br />

1~120<br />

MV-H High limit of MV<br />

–3~103% %<br />

AO-H Upper scale of AO<br />

0~100% %<br />

AO-L Lower scale of AO<br />

0~100% %<br />

Station No. for communication<br />

NORM<br />

REV<br />

NORM<br />

REV<br />

MV-L Low limit of MV<br />

–3~103% %<br />

BURN Action when input is abnormal 0~4<br />

AOT Kind of Analog ourput source PV<br />

SV<br />

MV<br />

1~15<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Amp.<br />

Amp.<br />

Code No.<br />

1 word<br />

DEC<br />

1 word<br />

DEC<br />

1 byte DEC<br />

Second<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Engineering<br />

unit<br />

Second<br />

Second<br />

Second<br />

AL11 Set value for Alarm 11<br />

0~100%<br />

Engineering<br />

unit<br />