GROUND HANDLING AND<br />
SERVICING HANDBOOK<br />
HARD COPY IS UNCONTROLLED. ONCE PRINTED, THIS PAGE MUST NOT BE RETAINED FOR FUTURE REFERENCE.<br />
BEFORE USING, MAKE SURE THIS HARD COPY IS THE LATEST ISSUE.<br />
(c) Close the window shades.<br />
(d) Set the gust locks.<br />
CAUTION: MAKE SURE THAT ALL COVERS ARE IN GOOD CON-<br />
DITIONS, WITH NO DAMAGE AND FREE OF LINTS. IF<br />
YOU DO NOT OBEY THIS PRECAUTION, DAMAGE TO<br />
THIS EQUIPMENT CAN OCCUR.<br />
(e) Install the covers to these parts:<br />
1. Pitot probe (GSE 009).<br />
2. Pitot-static probe (GSE 003).<br />
3. Dual static port (GSE 008).<br />
4. Engine (GSE 030).<br />
(f) Cover the outlet and inlet openings that follow with a cotton fabric or<br />
equivalent attached to the aircraft skin with adhesive tape:<br />
1. Ram air inlet<br />
2. Ground cooling fan inlet.<br />
3. Ground cooling fan exhaust.<br />
(g) Close all the doors and access panels.<br />
(h) Make sure that wheel chocks are installed.<br />
(i) Where there are freezing or ice conditions, do the subsequent step:<br />
1. Remove, drain and storage the waste tank. Refer to GHSH TASK<br />
12-15-03-600-801-A/300.<br />
NOTE: For matter of hygiene, we recommend that the waste<br />
tank be serviced.<br />
EFFECTIVITY: ALL 10-10-00-<strong>500</strong>-801-A/200<br />
Page 202<br />
Rev.06 - OCT 09/09<br />
Copyright © by <strong>EMB</strong>RAER S.A - All rights reserved - See title page for details.