REVISED SPECIFICATION TENDER SPECIFICATION No.:
REVISED SPECIFICATION TENDER SPECIFICATION No.:
REVISED SPECIFICATION TENDER SPECIFICATION No.:
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
6. SUBMISSION OF OFFERS<br />
6.1 In case of offers from other than the original equipment manufacturer (OEM),<br />
documentary evidence shall be submitted to prove that he is authorized to offer the<br />
item on behalf of OEM. The suppliers are also liable to produce the original invoice from<br />
OEM if warranted later.<br />
7. TESTS (As per IEC-571)<br />
Nature of test Type test Routine test<br />
Vibration and shock test<br />
√<br />
Performance test<br />
√<br />
Dielectric voltage withstand test √ √<br />
8. TYPE TEST:<br />
VIBRATION AND SHOCK TEST:<br />
The test sample along with its mounting arrangement shall be subjected to the vibration<br />
and shock tests as given below.<br />
8.1 The supplier shall make available one loco set of material as prototype for inspection<br />
and tests at his works and advise the Dy.Chief Electrical Engineer, Chittaranjan as and<br />
when such sample is ready.<br />
8.2 The prototype testing facilities must be arranged by the supplier at his own cost. Tests<br />
shall be carried out as per relevant IEC standard mentioned above. The renderer shall<br />
clearly indicate in the offer, his preparedness for carrying out the prototype tests and<br />
adequacy of facilities to carry out the type /routine test at his premises / on any govt.<br />
approved lab.<br />
8.3 VIBRATION:<br />
The equipment shall be mounted in machine room of electric locomotive and should be capable<br />
to withstand vibration for traction duty as per IEC 61373<br />
The sample with mounting arrangement should be subjected to sinusoidal vibration, the<br />
frequency of which is to be varied progressively between 1 Hz and 100 Hz and amplitude (in<br />
mm) as per:<br />
A=25/f for f between 1Hz and 10 Hz<br />
A=250/f² for f between 10Hz and 100 Hz<br />
The duration will be 10 min. Possibility of resonance is to be detected in this duration.