6. SUBMISSION OF OFFERS<br />

6.1 In case of offers from other than the original equipment manufacturer (OEM),<br />

documentary evidence shall be submitted to prove that he is authorized to offer the<br />

item on behalf of OEM. The suppliers are also liable to produce the original invoice from<br />

OEM if warranted later.<br />

7. TESTS (As per IEC-571)<br />

Nature of test Type test Routine test<br />

Vibration and shock test<br />

√<br />

Performance test<br />

√<br />

Dielectric voltage withstand test √ √<br />

8. TYPE TEST:<br />

VIBRATION AND SHOCK TEST:<br />

The test sample along with its mounting arrangement shall be subjected to the vibration<br />

and shock tests as given below.<br />

8.1 The supplier shall make available one loco set of material as prototype for inspection<br />

and tests at his works and advise the Dy.Chief Electrical Engineer, Chittaranjan as and<br />

when such sample is ready.<br />

8.2 The prototype testing facilities must be arranged by the supplier at his own cost. Tests<br />

shall be carried out as per relevant IEC standard mentioned above. The renderer shall<br />

clearly indicate in the offer, his preparedness for carrying out the prototype tests and<br />

adequacy of facilities to carry out the type /routine test at his premises / on any govt.<br />

approved lab.<br />

8.3 VIBRATION:<br />

The equipment shall be mounted in machine room of electric locomotive and should be capable<br />

to withstand vibration for traction duty as per IEC 61373<br />

The sample with mounting arrangement should be subjected to sinusoidal vibration, the<br />

frequency of which is to be varied progressively between 1 Hz and 100 Hz and amplitude (in<br />

mm) as per:<br />

A=25/f for f between 1Hz and 10 Hz<br />

A=250/f² for f between 10Hz and 100 Hz<br />

The duration will be 10 min. Possibility of resonance is to be detected in this duration.